• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 47
  • 11
  • 4
  • Tagged with
  • 62
  • 62
  • 31
  • 15
  • 15
  • 12
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Etude de l'influence de la convection naturelle et forcée sur le processus de la solidification : cas d'un alliage métallique binaire. / Study of the influence of natural and forced convection on the solidification of a binary metal alloy.

Hachani, Lakhdar 08 October 2013 (has links)
Ce travail se situé dans la perspective d'un contrôle de la structure de solidification des alliages métalliques sous l'effet de la convection naturelle et forcée afin d'améliorer à terme la maîtrise des microstructures de solidification grâce à un brassage électromagnétique efficace permettant d'avoir une homogénéisation du bain liquide qui par la suite peut améliorer la microstructure finale de l'alliage. La possibilité retenue dans ce travail est de réaliser ce brassage sans contact avec la solution liquide (alliage sous fusion) et sans pollution par d'autres éléments en utilisant un brassage par la force de Lorentz. L'objet de la thèse comporte une étude théorique à la fois expérimentale basée sur une installation expérimentale particulièrement documentée et instrumentée, développée au laboratoire SIMAP/EPM à Grenoble, nommée AFRODITE. Ce dispositif expérimental permet de fournir des données de quantitatives et qualitatives sur le processus de solidification des alliages métalliques. Ces données sont nécessaires à la contribution aux études menées sur la solidification des alliages métallique et enrichir la base des donnée des modèles numériques développés pour prédire les défauts liés à la solidification. L'alliage choisi dans notre travail est l'étain-plomb, vue sa basse température de fusion. Les expériences envisagées visent à étudier l'effet de deux modes de configuration dynamique sur la solidification de l'alliage Sn-Pb: la convection thermosolutale avec la variation de deux paramètres essentiels (la vitesse de refroidissement et la différence de température expérimentale) et la convection forcée par l'utilisation de plusieurs modes de brassage électromagnétique. Cette étude s'intéresse en particulier à la caractérisation des macrostructures et les défauts liés à la macroségrégation. L'originalité de l'étude vise à mesurer in situ les températures instantanées. Ceci nous a permis d'évaluer l'évolution du transfert thermique due à la convection naturelle/forcée, ainsi que leurs influence sur le processus de la solidification sous différents aspects. L'analyse post-mortem de l'alliage métallique, fournit la structure de solidification et la distribution des ségrégations à différentes échelles (mésoscopique et macroscopique). / This work is situated in the context of control of the solidification of metallic alloys structure under the effect of natural and forced convection to enhance control of solidification microstructures term through effective electromagnetic stirring to have a homogenizing the liquid which may subsequently improve the final microstructure of the alloy. The possibility considered in this work is to achieve this stirring without contacting the liquid solution (alloy in fusion) and pollution by other elements using a patch by the Lorentz force. The purpose of the thesis consists both a theoretical and experimental study based on an experimental setup particularly documented and instrumented developed / EPM SIMAP laboratory in Grenoble, named AFRODITE. The experimental device used to provide quantitative and qualitative data on the process of solidification of metallic alloys. These data are necessary for the contribution to studies on the solidification of metallic alloys and enrich the data base developed numerical models to predict defects related to solidification. The alloy selected from our work is tin-lead, for its low melting temperature. The proposed experiments are designed to study the effect of two types of dynamic configuration on the solidification of Sn-Pb alloy: the thermosolutal convection with the variation of two essential parameters (cooling rate and the difference in experimental temperature) and forced convection by the use of several modes of electromagnetic stirring. This study is particularly interested in the characterization of macrostructures and defects related to macrosegregation. The originality of this study is to measure in situ instantaneous temperatures. This allowed us to assess the evolution of the heat transfer due to natural / forced convection and their influence on the process of solidification in different aspects. The post-mortem analysis of the metal alloy provides the solidification structure and distribution of segregation at different scales (mesoscopic and macroscopic).
42

Etude expérimentale de la convection naturelle en canal vertical à flux de chaleur imposé : application au rafraîchissement passif de composants actifs de l'enveloppe des bâtiments / Experimental study of a natural convection flow in an isoflux heated vertical channel : application to passive cooling of active components of the building envelope

Daverat, Christophe 15 October 2012 (has links)
La réduction de la consommation des bâtiments passe par : l'économie d'énergie, l'efficacité énergétique et l'utilisation des énergies renouvelables. Sur ce dernier point, l'intégration à grande échelle de composants photovoltaïques (PV) est une solution. Le rendement et la durée de vie des cellules PV en silicium cristalin diminuant avec l'augmentation de leur température de fonctionnement, il est essentiel de mettre au point des configurations d'intégration limitant leur échauffement. L'intégration en configuration de double-peau – la surface PV est séparée du bâtiment par une lame d'air – est une solution prometteuse. Sous l'effet de la chaleur, un écoulement de convection naturelle se met en place entre les deux parois, refroidissant ainsi les panneaux PV. Cet écoulement peut également servir de moteur pour la ventilation en été, et de préchauffage de l'air en hiver. Cette étude, expérimentale, fait partie d'un projet visant à comprendre le fonctionnement des double-peaux PV en analysant séparément les différents phénomènes physiques avant de prendre en compte l'ensemble des couplages. Elle porte plus particulièrement sur la convection naturelle au sein des double-façades verticales. Ici, la double-peau est modélisée par un canal vertical dont les deux parois principales sont chauffées sous des conditions de flux imposé. Un banc d'essais a été développé pour étudier la convection naturelle dans un canal vertical en eau. L'eau a été choisie pour se placer dans le cas d'un écoulement de convection pure (pas de rayonnement entre les parois). C'est un canal vertical de 65 cm de haut avec un écartement réglable placé dans une cuve de 1,5 m de haut contenant 160 L d'eau. Les parois sont chauffées à l'aide de 24 chaufferettes indépendantes délivrant un flux de chaleur uniforme, ce qui permet d'appliquer différentes configurations de chauffage. Des mesures de flux et de température sont réalisées au niveau des parois, et un système couplant de la velocimétrie laser Doppler deux composantes à un micro-thermocouple (25 μm) a été développé pour avoir accès aux vitesses verticale et horizontale et à la température dans le canal. Ce banc et son instrumentation sont décrits et les incertitudes de mesure associées ont été caractérisées. La configuration de chauffage uniforme symétrique a été étudiée ici pour différentes puissances injectées. Les profils de vitesse et de température moyennes mettent en évidence la présence d'un changement de régime d'écoulement dans le canal pour un nombre de Rayleigh indéntifié. L'étude approfondie des profils des fluctuations de vitesse et de température a permis de mettre au point une modélisation comportementale de ce changement de régime. De plus, une première approche est développée pour évaluer la pression dans le canal à partir de l'analyse et de l'estimation des différents termes de l'équation de conservation de la quantité de mouvement. / Reducing the building consumption passes through : energy saving, energy efficiency and the use of renewable energy sources for a local production of electricity. For the last point, the building integrated photovoltaic systems represent a promising solution. However, electrical yield and life time of silicon solar cells decrease with the increase of its operating temperature, that is why integrated configurations which limits cell overheating must be developed. The solution considered is the double-skin façade configuration : photovoltaic panels are separated from the building wall(or roof) by an opened air channel. This induces a natural convection flow that cools the rear surface of the photovoltaic panels. This flow can also be used for natural ventilation of buildings in summer or for air preheating in winter. This experimental study is part of a project on photovoltaic double-skin façades. In this project, each physical phenomena are analysed separately first, and the coupling between the different phenomena are studied in a second time. This thesis deals with the natural convection into the vertical double-skin façades. The system is modelled by a vertical channel with isoflux heating at the two mains walls. An experimental apparatus was developed in the laboratory for studying natural convection in water in a vertical channel. Water is used as the working fluid to avoid radiative heat transfer and obtain a pure convective flow. The channel is 65 cm high with an adjustable gap. It is placed in a 1.5 m high glass tank filled with 160 L of distilled water. The main walls are heated through 24 independant electrical heaters maintaining a constant heat flux, which allows differents boundary condition (symmetrical, asymmetrical, uniforme, alternated, etc). Heat flux and temperature measurements are made at the walls. The velocity (horizontal and vertical) and temperature of the flow are measured through a two components Laser Doppler Velocimetry system combined with a micro-thermocouple (25 μm diameter). This apparatus is described in details and the measurement uncertainties were characterized. The symmetrical uniform heating configuration was studied here with the analyse of velocity and temperature profiles in the channel for several input power (46 W to 562 W). These profiles show a change in flow regime in the channel that is analysed with turbulent quantities along the channel. Moreover, the pressure is estimated in the channel from the analysis of all the terms of the momentum conservation equations.
43

Experimental investigation of thermal and fluid dynamical behavior of flows in open-ended channels : Application to Building Integrated Photovoltaic (BiPV) Systems / Etude expérimentale du comportement dynamique thermique et fluide des flux dans les canaux ouverts : Application à la création de systèmes photovoltaïques intégrés au bâti (BIPV)

Sanvicente, Estibaliz 03 July 2013 (has links)
Face à la problématique énergétique, les solutions envisagées dans le domaine du bâtiment s’orientent sur un mix énergétique favorisant la production locale ainsi que l’autoconsommation. Concernant l’électricité, les systèmes photovoltaïques intégrés au bâtiment (BiPV) représentent l’une des rares technologies capables de produire de l’électricité localement et sans émettre de gaz à effet de serre. Cependant, le niveau de température auquel fonctionnent ces composants, influence sensiblement leur efficacité ainsi que leur durée de vie. Ces deux constats mettent en lumière l’importance du refroidissement passif par convection naturelle de ces modules. La configuration privilégiée est une configuration d’intégration au sein d’une enveloppe ventilée qualifiée de double-peau photovoltaïque. La présente étude expérimentale porte sur les transferts de chaleur et les caractéristiques de l’écoulement en convection naturelle dans des canaux chauffés verticaux ou inclinés. Deux bancs d’essais existants ont été complétés afin d’obtenir des données. Ils sont composés de deux plaques planes parallèles séparées par une lame d’air. Les parois sont soumises à des conditions aux limites de type densité de flux imposée. Les températures moyennes à la paroi ont été mesurées par thermocouples. Un système de vélocimétrie par image de particules a permis d’obtenir des profils de vitesse moyenne ainsi que les distributions d’intensité turbulente dans l’écoulement. Les champs de vitesse instantanée ont également été examinés. Trois configurations ont été étudiées avec un nombre de Rayleigh variant entre 3,86 x 105 et 6,22 x 106. La première est un canal vertical avec une des deux parois chauffée uniformément. La seconde est un canal vertical dans lequel les deux parois sont chauffées de façon non-uniforme et alternée. La troisième est de type canal incliné chauffé uniformément sur la paroi supérieure. Le rapport de forme du canal (largeur/hauteur) est de 1/15 pour le deux premières configurations et de 1/16 pour la troisième. Une attention particulière a été portée sur l’identification de la zone de transition laminaire-turbulent. L’étude a permis de mettre en évidence la sensibilité de l’écoulement aux perturbations extérieures. Pour un chauffage uniforme et asymétrique, à partir d’un nombre de Rayleigh Ra* de 3.5 x 106 et pour θ = 60° et 90°, il a été constaté que la propagation de structures cohérentes dans le canal a lieu à partir de la mi-hauteur de ce canal. Ces instabilités favorisent alors les transferts thermiques. Dans le cas d’un chauffage non-uniforme sur les deux parois du canal, l’écoulement est fortement perturbé ce qui conduit à l’augmentation du brassage et de la contrainte de Reynolds sur la majorité de la largeur du canal. Enfin, pour chacune des configurations, des corrélations permettant de quantifier les transferts de chaleur à la paroi et au sein de la lame d’air (nombre de Nusselt moyen en fonction du nombre de Rayleigh) ont été établies. / Among technologies capable to produce electricity locally without contributing to GHG releases, building integrated PV systems (BIPV) could be major contributor. However, when exposed to intense solar radiation, the temperature of PV modules increase significantly, leading to a reduction in efficiency so that only about 14% of the incident radiation is converted into electrical energy. The high temperature also decrease the life of the modules, thereby making passive cooling of the PV components through natural convection a desirable and cost-effective means of overcoming both difficulties. An experimental investigation of heat transfer and fluid flow characteristics of natural convection of air in vertical and inclined open-ended heated channels is therefore undertaken so as provide reliable information for the design of BIPV. Two experimental set ups were developed and used during the present investigations; one located at the CETHIL laboratory in Lyon, the F-device and the other located at the University of New South Wales in Sydney, the R-device. Both channels consisted of two wide parallel plates each of which could be subjected to controlled uniform or non-uniform heat fluxes. The investigation has been conducted by analyzing the mean wall temperatures, measured by thermocouples and mean velocity profiles and turbulent quantity distributions of the flow, measured with a PIV system. Flow patterns close to the heated faces were also investigated. The study is particularly focused on the transition region from laminar to turbulent flow. Three different heating geometric arrangements are examined in the modified Rayleigh number range from 3.86 x 105 to 6.22 x 106. The first is a vertical channel with one wall uniformly heated while the other was unheated, the second was a vertical channel in which both walls were non-uniformly heated and the third is an inclined channel uniformly heated from above. In the vertical configurations the width-to-height channel aspect ratio was fixed at 1:15 and in the inclined ones at 1:16. It is shown that the flow is very sensitivity to disturbances emanating from the ambient conditions. Moreover, the propagation of vortical structures and unsteadiness in the flow channel which are necessary to enhance heat transfer, occurred downstream of the mid-channel section at Ra* = 3.5 x 106 for uniformly and asymmetrically heated channels inclined between 60° and 90° to the horizontal. Indeed, these unsteady flow phenomena appears upstream the location of the inflexion point observed in the temperature excess distribution of the heated wall. In the case of non-uniform heating on both sides of the channel, a stronger ‘disruption mechanism’ exists, which leads to enhanced mixing and increased Reynolds stresses over most of the width of the channel. Empirical correlations of average Nusselt number as a function of modified Rayleigh number were obtained for each configuration.
44

Modélisation des phénoménes transitoire lents avec la méthode de Boltzmann sur réseau / Modeling of slow transients with Boltzmann method

Thandavamoorthy, Gayathiri 01 April 2016 (has links)
Un nouveau logiciel CFD, LaBS, basé sur la méthode de lattice Boltzmann sur Réseau a été développé dans le cadre d'un projet entre universités et industries. LaBS est utilisé pour la simulation numérique des écoulements thermiques avec un nouveau modèle de frontière immergée pour les conditions limites thermiques. Ce modèle est basé sur la méthode de reconstruction de la fonction de distribution et est évalué pour des conditions limites coincidentes et non-coincidentes avec le maillage, sur le phénomène de diffusion thermique et de convection naturelle.Renault s'intéresse aux situations d'arrêt péage ou de contact coupé, pour lesquelles sont considérés un véhicule roulant à une vitesse soutenue, sur une autoroute par exemple, et qui subit un arrêt ou un ralentissement brutal (avec ou sans contact coupé).Dans ce genre de situation le refroidissement du compartiment moteur qui était assuré par le phénomène de convection forcé durant le roulage laisse place au phénomène de convection naturelle durant les phases de base vitesse ou de vitesse nulle.Le phénomène de convection naturelle est un phénomène lent, qui peut prendre plusieurs minutes à évacuer la chaleur accumulée dans le compartiment moteur. La présence de température élevée pendant une durée trop importante dans le compartiment moteur peut endommager certains composants qui possèdent des seuils de température critique.Pour anticiper ce problème de surchauffe du compartiment moteur, dans lequel un grand nombre de pièces à géométries complexes sont présentes, le phénomène de convection naturelle est étudié avec le nouveau modèle de frontière immergée thermique.%Ce modèle est d'abord testé sur des cas test académique pour validation et est ensuite appliqué au cas d'une voiture réelle.La modélisation des écoulements thermiques avec la méthodes de lattice Boltzmann sur Réseau (LBM) peut-être classée en trois catégories: l'approche multi-vitesse, l'approche hybride et l'approche à deux fonctions de distribution (DDF: Double-Distribution-Function).L'approche multi-vitesse, utilise une équation pour résoudre le champ de vitesse, de densité et de température qui sont résolus avec la LBM. Tandis que l'approche hybride et l'approche DDF utilise un jeux de deux équations, un pour résoudre le champ de vitesse et de densité et l'autre pour résoudre le champ de température.L'approche hybride résout le champ de vitesse et de densité avec la LBM et utilise une méthode de différence finie ou de volume fini pour résoudre le champ de température. L'approche DDF résout quand à elle les deux équations avec la LBM.Le modèle thermique utilisé dans LaBS est basé sur l'approche DDF où les deux équations sont couplées par l'hypothèse de Boussinesq. Le champ de vitesse et de densité est résolu avec un réseau de dix-neuf vitesses discrètes (D3Q19) et champs de température est résolut soit par un réseau à dix-neuf vitesses discrètes (D3Q19) soit par un réseau à sept vitesses discrètes (D3Q7).Le nouveau modèle de frontière immergée décompose la fonction de distribution aux noeuds frontière en sa partie à l'équilibre et hors équilibre. La partie hors équilibre est calculée à partir d'une formulation théorique issus du développement de Chapman-Enskog.La validation du modèle DDF implémenté dans LaBS est faite sur un ensemble de cas test de complexité croissante. Les résultats obtenus avec LaBS sont comparés aux solutions analytiques ou encore à des articles de référence et sont en accord avec les résultats attendus. Ils montrent que qualitativement les résultats sont aussi bons pour le modèle D3Q19/D3Q19 que pour le modèle D3Q19/D3Q7 mais que quantitativement le modèle D3Q19/D3Q19 reste meilleur. / A new three-dimensional CFD solver, LaBS, based on the lattice Boltzmann alogorithms has been developed in a framework of university and industry consortium. In this thesis, this solver is used to simulate thermal flows, with a new thermal boundary condition for immersed solid boundary. The new proposed thermal boundary condition is based on the reconstruction method of the distribution function and is evaluated for immersed solid with coincident and non-coincident wall on the case of diffusion and natural convection phenomena.Renault case study, deals with a vehicle moving at constant speed (highway) that suddently slows down and stops (with or without a cut off contact). In such situation the cooling of the engine compartment first driven by forced convection during taxiing stage, abruptly switches to natural convection in low velocity stages. As natural convection is a slow process, it can take several minutes to remove the accumulated heat in the engine compartment. Such duration could be damaging for some components of the engine compartement which do not tolerate high temperature.In order to anticipate overheating of the engine compartment, where a lot of automotive parts with complex geometry are present and to avoid the above mentioned damages, the phenomenon of natural convection is here studied with the new thermal boundary condition.%The new proposed thermal boundary condition is first tested on academic case studies for validation, and then applied to the case of a real car.The modelling of thermal flows with the lattice Boltzmann method (LBM) can be classified into three categories: the multispeed approach, the hybrid approach and the double-distribution-function (DDF) approach. The multispeed approach, uses only one equation to resolve velocity, density and temperature field, which is solved by the LBM. Whereas the hybrid approach and the DDF approach utilize two sets of equations, one to resolve velocity field and density field and another to resolve temperature field. The hybrid approach solves velocity field and density field by the LBM method and the temperature field by finite-different or finite-volume methods. On the other hand the DDF approach solves the two equations with LBM.The thermal model used in the solver LaBS is based on the coupled DDF approach. In this model, the flow field is solved by a D3Q19 velocity model while the temperature field is solved by a D3Q19 or a D3Q7 velocity model. The coupling between the momentum and the energy transport is made by the boussinesq approximation. The new proposed thermal boundary condition decomposes the distribution function at the boundary node into its equilibrium and non-equilibrium part. The non-equilibrium part is calculated from the theoretical solution based on Chapman-Enskog developement.LaBS thermal model based on the coupled DDF approach is evaluated on a set of cases with increasing complexity. The results obtained with LaBS are compared with analytical solutions or with reference articles and are in a good agreement with the results expected. Results show that the model D3Q19/D3Q7 is qualitatively as good as the model D3Q19/D3Q19 but quantitatively the model D3Q19/D3Q19 remains the best.
45

Modélisation des phénomènes convectifs lors du changement de phase solide-liquide par utilisation de l'équation de diffusion de la chaleur et d'une forme modifiée de la conductivité

Vidalain, Guillaume 12 April 2018 (has links)
Dans ce mémoire on s'intéresse à la modélisation du changement de phase solide-liquide en convection naturelle et en convection forcée en utilisant l'équation de diffusion de la chaleur et une forme modifiée de la conductivité. Comme on ne cherche pas à résoudre le champ des vitesses, on intègre à l'intérieur de la conductivité modifiée les effets thermiques des mouvements convectifs, puis on résout l'équation de conduction en utilisant ces conductivités modifiées. L'objectif du mémoire est de prédire la position de l'interface solide-liquide en fonction du temps dans un processus de fusion ou de solidification en présence de convection, et ce avec un modèle conductif. Dans les deux cas types que nous avons traités, la valeur de la conductivité modifiée à utiliser dans le modèle conductif simplifié est d'abord estimée par une étude d'ordre de grandeur. Le premier cas type étudié est celui du changement de phase en présence de convection forcée se déroulant dans une conduite à paroi froide. On a réussi à développer une relation permettant d'obtenir la valeur de la conductivité modifiée directionnelle à utiliser dans le modèle conductif en fonction du nombre de Reynolds de l'écoulement ainsi que du facteur de forme de la conduite. Cette relation a montré de bons résultats en comparaison avec ceux issus d'un modèle numérique complet plus classique (CFD). Le deuxième cas type étudié est celui de la fusion d'un matériau sous l'effet de la convection naturelle à l'intérieur d'une enceinte. Nous avons réussi à paramétrer l'évolution des valeurs de conductivité modifiée à utiliser par notre modèle conductif, celles-ci sont fonction de l'avancement du front de fusion et du nombre de Nusselt. Cette modélisation est comparée à la fois avec les résultats fournis par un modèle numérique complet (CFD) mais aussi avec des résultats expérimentaux issus de la littérature. Ces comparaisons ont montré une bonne concordance entre notre modélisation et la réalité. / In this work we have developed an enhanced conduction model for predicting solid-liquid interface positions in convection-dominated phase-change processus. The flow field is not calculated and the effects of convection are taken into account via the modification of the material conductivity. Our objective is to obtain a good approximation of the solid-liquid interface evolution. It is shown that the enhanced thermal conductivity of the melt may be formulated in terms of directional thermal conductivity components and that their value may be correlated in terms of dimensional numbers obtained from an order of magnitude analysis. The proposed approach is then tested for two different cases. The first test case is devoted to forced convection dominated solidification in a duct while the second test case is concerned with buoyancy dominated melting in an enclosure. The results of the simulations using our conduction model are then compared with a full CFD model and in the case of melting in an enclosure experimental data, they show good agreements.
46

Numerical simulations of natural or mixed convection in vertical channels : comparisons of level-set numerical schemes for the modeling of immiscible incompressible fluid flows / Simulations numériques de la convection naturelle ou mixte dans des canaux verticaux : comparaisons de schémas numériques level-set pour la modélisation d'écoulements de fluides immiscibles et incompressibles

Li, Ru 12 December 2012 (has links)
Le but de ce mémoire de recherche est d'étudier les convections naturelle et mixte d'écoulements fluides, et de développer et valider des méthodes numériques pour le suivi d'interfaces afin de traiter plus tard des écoulements incompressibles de fluides immiscibles. Dans une première étape, une méthode numérique originale, basée sur des discrétisations Volumes Finis, est développée pour modéliser les écoulements à faible nombre de Mach et grands écarts de température. Trois applications physiques, portant sur l'écoulement d'air à travers des plaques verticales parallèles chauffées, sont étudiées. Nous avons montré que l'espacement optimal, correspondant au pic de flux de chaleur transféré d'un réseau de plaques parallèles isothermes refroidies par convection mixte, est plus faible que ceux obtenus en convections naturelle ou forcée lorsque la chute de pression à la sortie est constante. Nous avons également prouvé que les écoulements de convection mixte à débit imposé peuvent présenter des solutions physiques inattendues ; un modèle alternatif basé sur une pression totale imposée à l'entrée et une pression fixée à la sortie donne de meilleurs résultats. Pour des canaux soumis un flux de chaleur sur une paroi seule, le rayonnement de surface tend à supprimer l'apparition des recirculations à la sortie et à uniformiser les températures des parois. Dans une seconde étape, le modèle mathématique couplant les équations de Navier-Stokes incompressibles et la méthode Level-Set pour le suivi d'interfaces est développé. Des améliorations de la conservation du volume fluide par l'utilisation de schémas de discrétisation d'ordres élevés (ENO-WENO) pour l'équation de transport et des variantes de l'équation de la distance signée sont discutées / The aim of this research dissertation is at studying natural and mixed convections of fluid flows, and to develop and validate numerical schemes for interface tracking in order to treat incompressible and immiscible fluid flows, later. In a first step, an original numerical method, based on Finite Volume discretizations, is developed for modeling low Mach number flows with large temperature gaps. Three physical applications on air flowing through vertical heated parallel plates were investigated. We showed that the optimum spacing corresponding to the peak heat flux transferred from an array of isothermal parallel plates cooled by mixed convection is smaller than those for natural or forced convections when the pressure drop at the outlet keeps constant. We also proved that mixed convection flows resulting from an imposed flow rate may exhibit unexpected physical solutions; alternative model based on prescribed total pressure at inlet and fixed pressure at outlet sections gives more realistic results. For channels heated by heat flux on one wall only, surface radiation tends to suppress the onset of recirculations at the outlet and to unify the walls temperature. In a second step, the mathematical model coupling the incompressible Navier-Stokes equations and the Level-Set method for interface tracking is derived. Improvements in fluid volume conservation by using high order discretization (ENO-WENO) schemes for the transport equation and variants of the signed distance equation are discussed
47

Modèles numériques à faibles nombres de Mach pour l'étude d'écoulements en convection naturelle et mixte

Haddad, Adel 15 December 2011 (has links)
Le modèle numérique que nous avons développé au cours de cette thèse présente deux caractéristiques principales : un modèle dilatable pour l'eau et la prise en compte de domaines ouverts. Les difficultés associées au premier aspect concernent l'adaptation de la loi d'état de l’eau au modèle dilatable sous l’approximation à faibles nombres de Mach, tandis que celles associées au second sont relatives à la mise en œuvre de conditions aux limites numériques de sortie compatibles avec l'algorithme de projection utilisé. Les résultats de simulations d'écoulement de convection mixte en canal horizontal chauffé par le bas ont été confrontés à celles utilisant l'approximation de Boussinesq et aux expériences. / The 3D numerical model which we developed in this thesis presents two main features: a Low-Mach-Number approximation for water along with an open boundary condition formulation. Indeed, the difficulties related to the former point stand in a computationally efficient adaptation of the water equation of state in the framework of Low Mach number approximation, whereas the difficulties related to the latter concern the introduction of Open Boundary Conditions in the projection algorithm used. We have computed a mixed convection flow in a horizontal channel uniformly heated from below and compared the results obtained with both the Boussinesq approximation and experimental results.
48

Contribution à la caractérisation numérique et expérimentale des échanges thermiques externes des machines électriques totalement fermées et non ventilées avec introduction des données d’incertitudes / Contribution to the numerical and experimental characterization of external thermal exchanges of totallly enclosed and non-ventilated electrical machines with introduction of uncertainty data

Meksi, Olfa 30 June 2017 (has links)
En plus des aspects électrique, magnétique, vibro-acoustique et mécanique, les considérations thermiques doivent être prises en compte lors des phases de conception et d’optimisation des machines électriques. Ce mémoire se porte sur l’analyse et la simulation du comportement thermique des machines électriques Totalement Fermées et Non Ventilées (TFNV) et plus particulièrement sur le cas de la machine Synchro-réluctante (Synchrel), utilisée comme actionneur d’embrayage. Un modèle thermique détaillé (MTD), décrivant le comportement thermique de la machine Synchrel est conçu. Ce MTD proposé est construit grâce à une combinaison de la méthode à Constantes Localisées (CL) et d’une technique numérique de type Mécanique des Fluides Numériques (MFN). La première méthode est dédiée à la modélisation des transferts conductifs et radiatifs. La seconde permet de modéliser le mécanisme de refroidissement par convection naturelle autour de la machine Synchrel. Compte-tenu de l’importance du mode de refroidissement sur l’évolution des températures critiques, l’approche MFN peut apporter plus de précision. Par contre, elle nécessite des temps de calcul importants ce qui freine son utilisation. Afin de surmonter cette problématique, les résultats numériques obtenus pour des points de fonctionnement particuliers sont utilisés afin de définir des relations de corrélation analytiques. Cette analyse numérique est accompagnée d’une démarche expérimentale afin d’élaborer les corrélations expérimentales correspondantes. L’étude montre que les solutions numériques peuvent converger vers des solutions plus précises si l’on tient compte des données d’incertitudes introduites par cette approche. La deuxième problématique traitée est la détermination des Résistances Thermiques de Contact (RTCs) des machines électriques. Elles constituent des paramètres clefs dans la définition du MTD complet. La démarche de détermination des RTCs est basée sur deux approches d’identification paramétrique. La première est basée sur des observations expérimentales du comportement thermique de la machine. La seconde est basée sur une approche mathématique de réduction de modèle. Les valeurs déterminées sont cohérentes avec la littérature, bien que la machine Synchrel diffère en topologie, taille et puissance. En utilisant la corrélation d’origine numérique du phénomène de convection externe, le MTD complet est alors utilisé afin d’évaluer la variation de température due à l’erreur introduite par la MFN. En utilisant la corrélation expérimentale, le MTD complet est validé. Les approches d’identification paramétrique conduisent à la construction de deux modèles thermiques de second ordre de la machine. Ces modèles permettent la surveillance du comportement thermique du bobinage et du carter. Ces deux modèles simplifiés font montre d’une prédictibilité satisfaisante au regard de leur simplicité. / In addition to electrical, magnetic, vibro-acoustic and mechanical aspects, thermal considerations must be taken into account during the design and optimization of electrical machines. This study focuses on the analysis and the simulation of the thermal behavior of Totally Enclosed Non Ventilated (TENV) electric machines, specifically a Synchro-reluctant motor (Synchrel) in the context of an automotive application : a clutch actuator. A detailed thermal model (MTD) describing the thermal behavior of the Synchrel machine is designed. This proposed MTD is based on a combination of the Lumped Parameter Thermal Network method (LPTN) and the Computational Fluid Dynamics (CFD) methods. The first method is dedicated to model the conductive and radiative heat transfers. CFD techniques are dedicated to model the cooling mechanism based on the natural convection around the Synchrel machine. Since the critical temperature is very sensitive to the cooling mode, the CFD approach is used in this study to provide more accurate results. On the other hand, it requires considerable computing time, which prevents its use in design studies based on optimization methods. In order to overcome this problem, only some numerical results obtained for particular operating points are used to define an analytical correlation based on the numerical calculation relations. This numerical analysis goes with an experimental approach in order to elaborate the corresponding experimental correlations. This study shows that numerical solutions can present a good accuracy, if uncertainty data introduced by this approach are taken into account. The second research problem addressed in this study is the determination of the Contact Thermal Resistances (RTCs), which are key parameters in the definition of the MTD. The determination procedure of the RTCs is based on two parametric identification approaches. The first one is experimental and based on some observations of the thermal behavior of the machine. The second one is based on a mathematical model reduction approach. The determined values are consistent with results from literature, although the Synchrel machine differs in topology, size and power. Using the numerical correlations, the MTD is used to evaluate the temperature deviation due to error terms introduced by the CFD approach. Then, using these experimental correlations, the MTD’s quality can be checked and approved. Parametric identification approaches lead to the construction of two secondorder thermal models of the machine. These models allow monitoring the thermal behavior of the winding and the casing. Both simplified models show satisfactory predictability with respect to their great simplicity.
49

Modèle simplifié de changement de phase en présence de convection et rayonnement : application à un mur translucide associant superisolation et stockage d'énergie thermiques / Development of a simplified model for phase change in presence of natural convection and radiation : application to a novel heat storage translucent superinsulated wall

Souayfane, Farah 26 November 2018 (has links)
Cette thèse vise à étudier l'exploitation du rayonnement solaire grâce à un nouveau concept de mur capteur passif. Dans ce contexte, le comportement thermique d’un mur solaire semi-transparent a été étudié. Le mur fournit un éclairage naturel et est composé d’une couche d’aérogel de silice assurant une isolation thermique et acoustique, et d’un MCP. Ce dernier est contenu dans des briques de verre assurant l’absorption, le stockage et la restitution de chaleur. Ce mur a été caractérisé expérimentalement au centre PERSEE à Sophia. Il a été remarqué que la performance thermique du mur est élevée en hiver, tandis qu’une surchauffe estivale a été rencontrée. Un modèle numérique simplifié a été développé pour modéliser la convection naturelle et le rayonnement pendant la fusion du MCP. Ce modèle est validé à l’aide d’un modèle CFD, et des résultats de Benchmark. Pour optimiser la performance du mur en été, un modèle numérique du transfert de chaleur à travers le mur a été développé sous MATLAB. Ce modèle a été couplé à TRNSYS afin d’évaluer la performance thermique de l'ensemble du bâtiment. Le modèle couplé a été validé expérimentalement. Le comportement thermique du mur est testé dans des différents climats, et des solutions passives sont proposées pour assurer le confort thermique. Enfin, ce modèle a permis d'étudier le comportement thermique annuel d’un bâtiment intégrant un mur MCP- aérogel dans son enveloppe et une étude économique a été réalisée. Ces études ont confirmé l'intérêt du mur vis-à-vis de l'amélioration des performances énergétiques du bâtiment. La faisabilité économique de l'application du mur dépend du climat, du coût d’énergie, et du coût d'investissement. / This thesis aims to study the exploitation of solar radiation thanks to a new concept of passive sensor wall. In this context, the thermal behavior of a novel semi-transparent solar wall has been studied. The wall is composed of glazing, silica aerogel (TIM) and glass bricks filled with fatty acids (PCM). This wall provides storage and restitution of heat, thermal-acoustic insulation and daylighting. The thermal performance of the TIM-PCM wall is tested in a full-sized test cell located in Sophia, PERSEE center. In winter, particularly in sunny cold days, the PCM absorbs solar radiation, melts, and then releases the stored heat to the building at night. During summer, overheating is encountered, the PCM remains in its liquid state and is unable to release the stored heat. A simplified model for PCM melting in presence of natural convection and radiation is developed and validated using a CFD model, and benchmark solutions. Then, a numerical model describing the heat transfer mechanisms through the wall is developed. This model is linked to TRNSYS to assess the thermal performance of the whole building. The MATLAB-TRNSYS model is then validated experimentally. The thermal behavior of the wall is tested under different climates, and passive solutions are proposed to ensure thermal comfort in summer. Finally, the validated model is used to study the annual thermal behavior of a building integrating TIM-PCM wall and an economic study is conducted. These studies confirm the interest of the wall vis-à-vis the improvement of energy performance of the building. The economic feasibility of applying the TIM-PCM wall depends mainly on climate, energy costs, and investment cost.
50

Influence d'un champ magnétique glissant sur la solidification dirigée des alliages métalliques binaires

zaidat, kader 02 November 2005 (has links) (PDF)
Dans le domaine de l'élaboration des alliages métalliques, les principaux enjeux industriels résident dans la possibilité de maîtriser la structure métallurgique ainsi que les défauts qui surviennent lors de la phase de solidification. Lors de la solidification, les mouvements hydrodynamiques dans la phase liquide ont une influence importante sur les propriétés du produit solidifié. Dans cette étude, la conception d'un nouveau dispositif BATMAF (Bridgman Apparatus with a Travelling MAgnetic Field) constitué d'un four de solidification dirigée et d'une bobine de Bitter permettant de produire un champ magnétique glissant a permis d'étudier l'influence d'une convection forcée sur la solidification dirigée des alliages métalliques binaires. Notre attention s'est plus particulièrement portée sur deux effets majeurs influencés par la présence de convection forcée ou non : la macroségrégation et la structure de grains pour un alliage d'Al-3.5%pdsNi en présence ou non de particules affinantes. La vitesse ainsi que le sens de l'écoulement forcé peuvent être contrôlés par l'application du champ magnétique glissant. Nous avons montré que dans le cas de notre alliage, la macroségrégation peut-être contrôlée et que de plus, l'espacement primaire dendritique est modifié en fonction du champ appliqué. En ce qui concerne les structures de grains, à l'aide d'un modèle analytique, nous montrons que l'extension de la couche solutale en avant du front de solidification varie en fonction du sens de l'écoulement au voisinage de la zone pâteuse. Ceci conditionne la possibilité pour les grains équiaxes de germer puis de croître et, par conséquent, l'obtention du régime équiaxe ou non. Enfin, dans le cas des alliages non affinés, dans un domaine d'intensité de brassage, un régime de grains libres allongés a pu être obtenu probablement par fragmentation. Cette étude démontre s'il en était besoin, l'importance cruciale de la maîtrise de la convection sur les macroségrégations et la structure des grains et ouvre des perspectives quant à l'utilisation du champ magnétique glissant pour leur contrôle

Page generated in 0.1293 seconds