• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 94
  • 1
  • 1
  • Tagged with
  • 97
  • 49
  • 40
  • 36
  • 29
  • 27
  • 24
  • 23
  • 18
  • 16
  • 15
  • 13
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Influência da contração de sinterização na adaptação de copings de Y-TZP: Efeito na distribuição de tensões / Influence of Sintering Shrinkage on the Fit of Y-TZP Copings: Effect on Stress Distribuition

Carlos Eduardo Edwards Rezende 07 July 2015 (has links)
A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adaptação de tais copings poderia impactar na distribuição de tensões em coroas cerâmicas bi-camadas com estrutura de zircônia. A contração de sinterização das três marcas comerciais de zircônia foi obtida experimentalmente a partir da mensuração de espécimes geométricos. Trinta e seis copings de zircônia confeccionados por CAD/CAM foram divididos em três grupos (n=12): ZMAX a partir de blocos de IPS E.max ZirCad (Ivoclar Vivadent; Liechtenstein); ZYZ blocos de InCeram YZ (Vita Zahnfabrik; Alemanha) e; ZMC zircônia de manufatura controlada (Zirklein/Biodinâmica; Brasil). Os copings foram escaneados em micro-CT antes a após a sinterização para que as alterações dimensionais decorrentes do processo de sinterização fossem obtidas a partir da mensuração de cortes específicos. Os dados das alterações dimensionais obtidos para os espécimes geométricos e para os copings foram confrontados com as taxas de contração de sinterização informadas pelos fabricantes dos blocos de zircônia. Os copings sinterizados foram assentados sobre um pilar de zircônia e levados ao micro-CT para averiguação da adaptação interna e marginal dos mesmos. As mensurações foram realizadas pelo software ImageJ em 33 pontos diferentes. Os dados da adaptação possibilitaram a comparação estatística (p0,05) entre marcas comerciais e locais de mensuração, bem como a comparação entre a adaptação obtida experimentalmente e àquela determinada no software CAD/CAM para confecção dos copings. As imagens de micro-CT dos copings com menor e maior espaçamento foram utilizadas para a construção de modelos de elemento finito tridimensionais visando avaliar a distribuição de tensões em função do espaçamento coping/pilar na região oclusal. A contração de sinterização obtida para os espécimes geométricos foi 21,59±1,14%; 20,63±0,96% e 20,73±0,92% para os grupos ZMAX, ZYZ e ZMC, respectivamente. Todos os grupos apresentaram diferença estatística entre a taxa de contração do fabricante e a obtida experimentalmente. A análise das alterações dimensionais dos copings demonstrou incompatibilidade entre a taxa de contração ocorrida nos copings e àquela informada pelos fabricantes dos grupos ZMAX e ZMC. Também houve diferença entre a taxa de contração dos espécimes geométricos e a dos copings para todos os grupos estudados. Não houve uniformidade de contração de sinterização das paredes dos copings. Não houve diferença estatística entre os grupos para a adaptação marginal, havendo diferença apenas para a adaptação interna e entre as diferentes regiões mensuradas, havendo maior espaçamento na região oclusal. Considerando as diferentes faces axiais do copings, houve maior espaçamento na região vestibular. A comparação entre a adaptação obtida e àquela determinada pelo sistema CAD/CAM demonstrou diferença estatística em determinadas regiões mensuradas para todos os grupos. A avaliação da distribuição de tensões pelo método de elementos finitos demonstrou maior concentração de tensão no modelo com maior espaçamento entre copings e pilar na porção oclusal. Concluiu-se que não houve uniformidade na contração de sinterização, a marca comercial dos blocos de zircônia influenciou na adaptação, os parâmetros de espaçamento copings/pilar determinados no sistema CAD/CAM não foram obtidos na prática e, um maior espaçamento interno entre coping e pilar na região oclusal resultou em maior concentração de tensões na coroa cerâmica. / The longevity of ceramic crowns depends, among other factors, on its fit and the stress distribution. There is no consensus regarding the better fitting of zirconia CAD/CAM made crowns over conventional methods and may be an influence of zirconia sintering shrinkage on the abutment/coping spacing. This study aimed at evaluating the dimensional changes from sintering process of three zirconia blocks trademarks, relating them to the fit of CAD / CAM made zirconia copings, and to evaluate how the fit of such copings could impact on the stress distribution in bilayered Y-TZP based ceramic crowns. The sintering shrinkage of the three trademarks of zirconia was obtained experimentally from the measurement of geometric specimens. Thirty-six zirconia copings made by CAD / CAM were equally divided into three groups (n = 12): ZMAX - from blocks of IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ blocks (Vita Zahnfabrik, Germany) and; ZMC - controlled manufacturing zirconia (Zirklein/Biodinamica, Brazil). The copings were scanned in micro-CT before and after the sintering so that dimensional changes from the sintering process were obtained from measurements taken from specific slices. Data from dimensional changes obtained for the geometric specimens and for the copings were faced with the sintering shrinkage rates reported by the manufacturers of zirconia blanks. The sintered copings were settled on a zirconia abutment and taken to the micro-CT scanner to evaluate its marginal and internal fit. Thirty three different points were measured using the Image J software. The data enabled the statistical comparison (p 0,05) between trademarks and measurement sites, as well as the comparison between the fit obtained experimentally with that stipulated by the CAD / CAM software. The micro-CT images of copings with smaller and larger cement space were used to build finite element models to evaluate stress distribution as a function of the abutment/coping fit in the occlusal aspect. The sintering shrinkage obtained for the geometric specimens was 21.59 ± 1.14%, 20.63 ± 0.96% and 20.73 ± 0.92% for ZMAX, ZYZ and ZMC groups, respectively. All groups showed statistical difference between the sintering shrinkage rate reported by the manufacturer and those obtained experimentally. The copings dimensional changes analysis showed incompatibility between the rates of shrinkage occurred in copings and to that reported by the manufacturers of ZMAX and ZMC groups. There was also a difference between the sintering shrinkage rate of the geometric specimens and the copings for all groups. In general, the sintering shrinkage of the walls of the copings showed no uniformity. Considering the adaptation of copings, there was no statistical difference between the groups for marginal fit, with differences only for internal fit and between the different regions measured. The thicker gap was found in the occlusal aspect. Considering the different axial aspects of the coping, the thicker spacing was found in the buccal region. The comparison between the fit obtained experimentally with that determined by the CAD/CAM system showed statistically significant differences in certain measured regions for all groups. The evaluation of stress distribution by finite element method showed higher stress concentration in the model with thicker cement space on the occlusal aspect. It was concluded that the sintering shrinkage did not occur uniformly; the adaptation of copings differed from a trademark to another; the obtained fitting did not achieve parameters determined in the CAD / CAM system; and a higher internal spacing between coping and abutment in the occlusal aspect resulted in higher stress concentration in the ceramic bi-layered crowns.
82

Avaliação da resistência à fadiga e modalidades de danos de coroas unitárias de dissilicato de lítio e resina nanocerâmica / Evaluation of the fatigue resistance and damage modes of lithuim disilicate and resin nanoceramic

Fernanda Ferruzzi Lima 10 June 2016 (has links)
Fraturas completas ou por delaminação são causas frequentes de insucesso entre coroas unitárias cerâmicas. O uso de materiais à base de resina composta, em contraponto à natureza friável das cerâmicas, parece ser uma alternativa para coroas posteriores, uma vez que apresentam processo de fabricação e reparo simplificados. Este estudo avalia a resistência à fadiga de coroas unitárias monolíticas CAD/CAM de resina composta nanocerâmica e cerâmica reforçada por dissilicato de lítio, bem como os danos causados pela aplicação de carga cíclica. Vinte e seis coroas monolíticas (n=13) foram cimentadas sobre réplicas de resina composta de um molar preparado e submetidas à ciclagem mecânica durante 2 milhões de ciclos, sob carga máxima de 350N à frequência de 2 Hz. Não foram observadas fraturas catastróficas ou fratura coesiva das coroas, resultando em sobrevivência de 100% para os dois materiais avaliados. As coroas foram incluídas em resina epóxi e desgastadas progressivamente à procura de danos. Coroas em resina nanocerâmica apresentaram-se íntegras, com trincas do cone externo, trincas do cone interno e com trincas radiais. As coroas em dissilicato de lítio apresentaram trincas do cone externo e interno, algumas atingindo a superfície interna. Os danos receberam escores de acordo com a severidade. Os dados foram submetidos à análise estatística pelo teste de Mann-Whitney (p =0,462), que não revelou diferenças estatísticas em relação aos danos observados. Concluímos que coroas monolíticas em dissilicato de lítio e resina nanocerâmica podem ser utilizadas na região posterior, pois apresentaram resistência à fadiga equivalente, sem diferença estatística entre os danos apresentados. / Bulk fractures or cohesive fractures are frequent complications for ceramic crowns. The use of resin- based materials, in contrast to the brittle nature of ceramics, seems to be an alternative to posterior crowns, since these materials present simplified manufacturing and repair tehniques. This study evaluates the fatigue resistance of monolithic CAD / CAM crowns made of resin nanoceramic and lithium disilicate reinforced ceramic, as well as the damage modes caused by the application of cyclic loading. Twenty-six monolithic crowns (n = 13) were cemented to a composite resin replica of a prepared molar and subjected to cyclic load over 2 million cycles under maximum load of 350N, at a frequency of 2 Hz. The crowns presented no catastrophic failures or cohesive fractures, resulting in survival of 100% for both materials. The crowns were embedded in epoxy resin and gradually grinded for damage analisys. Nanoceramic resin crowns presented no damage, outer cone cracks, inner cone cracks and radial cracks. Lithium disilicate crowns showed outer and inner cone cracks, some of the latter reaching the inner surface. Specimens were scored according to the severity of damage. Data was subjected to Mann-Whitney test (p = 0.462), which revealed no statistical difference. We conclude that lithium disilicate and resin nanoceramic monolithic crowns can be used in the posterior area, since they presented comparable fatigue resistance, with no statistical difference between damage modes.
83

Propriedades físicas da resina acrílica para coroas provisórias em função de diferentes técnicas de polimerização (rugosidade, porosidade, microdureza, sorção e solubilidade) / Physical properties of acrylic resin for provisional crowns under different curing techniques

Daniel Afonso Hiramatsu 27 November 2009 (has links)
Foi realizada uma avaliação in vitro da influência de três variáveis sobre a rugosidade, porosidade, microdureza, sorção e solubilidade de uma resina acrílica para coroas provisórias: ambiente de polimerização (ar/água), temperatura e pressão de acordo com 4 técnicas de manipulação, diretas e indiretas. Os corpos de prova foram confeccionados utilizando a resina poli (metilmetacrilato) (PMMA) Dencorcor nº 66. A rugosidade de superfície (Ra) foi verificada por um rugosímetro/perfilômetro. Na análise da porosidade foi utilizado um método quantitativo de contagem dos poros por área delimitada utilizando um microscópio comparador. A análise da microdureza foi feita antes e depois da simulação do desafio ácido ocorrido na cavidade bucal. Para a análise de sorção e solubilidade os espécimes foram submetidos a ciclos de hidratação e ressecamento e através da comparação entre as pesagens iniciais e finais foi possível estabelecer os resultados. Os resultados de Rugosidade foram favoráveis às técnicas indiretas (grupos I e II) com médias de Ra=0,141m e 0,181m, respectivamente, seguidos pelas técnicas diretas (grupos III e IV) com Ra=0,373m e 0,908m. Os resultados de porosidade foram de 0,8 poros por área delimitada para o grupo I, seguido do grupo II com 0,9 poros; grupo III com 7,2 poros e grupo IV com 124 poros. Os resultados de microdureza para todos os grupos evidenciaram diminuição da dureza após a ciclagem ácida com valores que diminuíram de 14,12 para 13,03 no grupo I; de 14,06 para 12,93 no grupo II; de 13,73 para 12,71 no grupo III e de 13,47 para 12,65 no grupo IV. Os resultados de sorção foram de 1,807% para o grupo I; 1,817% para o grupo II; 2,068% para o grupo III e 2,227% para o grupo IV. E os resultados de solubilidade foram 0,036% para o grupo I; 0,054% para o grupo II; 0,184% para o grupo III e 0,212% para o grupo IV. Os maiores valores de rugosidade e porosidade foram alcançados pelos corpos-de-prova confeccionados pelas técnicas diretas e os menores valores se deram nos corpos-de-prova confeccionados segundo as técnicas indiretas e pela técnica do pincel. O desafio ácido reduziu a dureza da resina acrílica, porém não houve diferença nos testes de dureza entre os diferentes grupos. Os espécimes confeccionados pelas técnicas indiretas apresentaram menor sorção e solubilidade quando comparadas às técnicas diretas. Portanto, as técnicas indiretas de confecção de coroas provisórias devem ser preferidas às técnicas diretas. / An in vitro evaluation of the influence of three variables (polymerization medium (air/water), temperature and pressure) on roughness, porosity, microhardness, sorption and solubility of an acrylic resin for provisional crowns was conducted according to 4 techniques (direct and indirect). The samples were prepared using a poly (methylmethacrylate) (PMMA) resin Dencor color No 66. The surface roughness (Ra) was evaluated with a perfilometer. Porosity was analyzed according a quantitative method of counting number of pores per area by using a comparator microscope. Microhardness readings were made before and after acid challenge simulation as in the oral cavity. For sorption and solubility analysis, specimens were subjected to successive cycles of dampening and dehydration to make comparisons of the initial and final weights. Roughness results were lower for indirect techniques (groups I and II) with averages of Ra = 0.141m and 0.181m, respectively, followed by direct techniques (groups III and IV) with Ra = 0.373m and 0.908m. Porosity results were 0.8 pores per area for the group I, 0.9 pores for group II, 7.2 pores for group III and 124 pores for group IV. All groups showed a decrease in hardness after acid cycling with values that ranged from 14.12 to 13.03 in group I, 14.06 to 12.93 in group II, 13.73 to 12.71 in group III, and 13.47 to 12.65 in group IV. Sorption results were 1.807% in group I, 1.817% in group II, 2.068% in group III, and 2.227% in group IV. Solubility results were 0.036% in group I, 0.054% in group II, 0.184% in group III and 0.212% in group IV. Higher values of roughness and porosity were obtained by specimens made by direct technique and lower values were achieved with specimens made by indirect technique and brush technique. The acid challenge statistically decreased hardness of the acrylic resin, but there was no statistical difference among different groups. The specimens prepared by indirect techniques showed lower sorption and solubility when compared to direct techniques. The indirect techniques for making provisional crowns should be preferred compared to direct techniques.
84

Influência dos ciclos de cocção da porcelana na força de destorque de parafusos de estruturas implanto-retidas / Influence of porcelain fire cycles on detorque resistance of screws from implant-retained structures

Torres, José Walter Murta, 1958- 21 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Tese (Doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T23:50:10Z (GMT). No. of bitstreams: 1 Torres_JoseWalterMurta_D.pdf: 1581851 bytes, checksum: 0bbcce2409164d19a4e51f955b38d595 (MD5) Previous issue date: 2013 / Resumo: Este trabalho avaliou a resistência ao destorque em parafusos de estruturas metálicas implanto-retidas fundidas em níquel-cromo (Ni-Cr) após fundição e simulação dos ciclos de cocção da porcelana. Dois implantes hexágono externo - com 3,75 mm de diâmetro - foram posicionados, com o auxílio de um paralelômetro fresador (1000N; Bio-art), na posição de segundo pré-molar e segundo molar num troquel de resina acrílica, de maneira a ficarem parcialmente submersos na resina expondo apenas suas plataformas de adaptação. Foram confeccionados 10 troqueis de resina acrílica (n=10). A partir de cada troquel foi obtida, pelo método de fundição da cera perdida, uma infraestrutura implanto-retida utilizando-se dois cilindros calcináveis tipo UCLA. A amostra foi submetida à força de torque de seus parafusos de fixação a 20 Ncm, registrada por meio de um torquímetro digital de precisão (Torque Meter TQ-8800; Lutron), e reapertados após 10 minutos. A força de destorque foi registrada após 24 horas do torque inicial. A resistência ao destorque foi analisada após fundição da estrutura protética e simulação dos três ciclos de cocção da porcelana (opaco dentina e glaze). Foram obtidas médias de destorque para cada estrutura nas distintas etapas de avaliação no estudo. Os dados foram analisados estatisticamente pelos testes ANOVA one-way e Bonferroni, com nível de significância de 5% (p<0,05). Os valores das médias da força de destorque dos parafusos por fase foram 13,95 ± 1,12 Ncm para pós-fundição, 15,20 ± 1,18 Ncm para ciclo Opaco, 15,85 ± 1,13 Ncm para ciclo Dentina e 16,80 ± 1,03 Ncm para o glaze. A força de destorque dos parafusos após a fundição foi significativamente menor do que a obtida para os grupos que simularam o ciclo de cocção da porcelana (p<0,05). Entre as fases de simulação dos ciclos cerâmicos, observou-se maior valor da força de destorque para o glaze (p<0,05), não sendo observadas diferenças estatisticamente significantes entre as fases opaco e dentina (p>0,05). Foi possível verificar que os ciclos de cocção da porcelana influenciam a resistência ao destorque em parafusos de estruturas metálicas implanto-retidas fundidas em níquel-cromo (Ni-Cr). Observou-se que os valores de destorque aumentaram gradativamente com cada ciclo de cocção da porcelana / Abstract: This study evaluated the resistance to detorque of screws from implant-retained metal structures cast in nickel-chromium (Ni-Cr) after metal casting and simulation of porcelain firing cycle. Two external hex implants - with 3.75 mm diameters - were placed with the help of a parallelometer cutter (1000N; Bio-art), in the position of second premolar and second molar in acrylic resin die, so as to be partially submerged in the resin exposing only their platforms for adaptation. Thereupon, 10 dies were made with acrylic resin (n= 10). An implant-retained infrastructure from each die was obtained by the method of lost wax casting, using two UCLA cylinders. The sample of acrylic structures were subjected to 20 Ncm of torque to its fixing screws registered by means of a precision digital torque wrench (Torque Meter TQ-8800; Lutron) and retightened after 10 minutes. The measure of detorque was recorded 24 hours after the initial torque. The detorque resistance was analyzed after denture casting, followed by the simulation of porcelain firing cycles (opaque, dentin and glaze). Detorque averages were obtained for each structure at different stages of evaluation in this study. Data was statistically analyzed by one-way ANOVA and Bonferroni tests, at 5% significance level (p>0.05). We performed necessary statistical tests. The mean detorque force of the screws per phase were 13.95 ± 1.12 Ncm for post-casting; 15.20 ± 1.18 Ncm for cycle opaque; 15.85 ± 1.13 Ncm for cycle dentin; and 16.80 ± 1.03 Ncm for glazing. The screw's post-casting detorque resistance was significantly lower than that observed for the groups simulating porcelain firing cycles (p<0.05). Among groups simulating ceramic's cycles, the highest detorque resistance was observed for glaze group (p<0.05), with no significant statistical differences among opaque and dentin groups (p>0.05). It was possible that the porcelain firing cycle influenced detorque resistance of screws in implant-retained metal structures cast in nickel-chromium (Ni-Cr). It was observed that detorque values gradually increased after each porcelain firing cycle / Doutorado / Protese Dental / Doutor em Clínica Odontológica
85

Propriedades físicas da resina acrílica para coroas provisórias em função de diferentes técnicas de polimerização (rugosidade, porosidade, microdureza, sorção e solubilidade) / Physical properties of acrylic resin for provisional crowns under different curing techniques

Hiramatsu, Daniel Afonso 27 November 2009 (has links)
Foi realizada uma avaliação in vitro da influência de três variáveis sobre a rugosidade, porosidade, microdureza, sorção e solubilidade de uma resina acrílica para coroas provisórias: ambiente de polimerização (ar/água), temperatura e pressão de acordo com 4 técnicas de manipulação, diretas e indiretas. Os corpos de prova foram confeccionados utilizando a resina poli (metilmetacrilato) (PMMA) Dencorcor nº 66. A rugosidade de superfície (Ra) foi verificada por um rugosímetro/perfilômetro. Na análise da porosidade foi utilizado um método quantitativo de contagem dos poros por área delimitada utilizando um microscópio comparador. A análise da microdureza foi feita antes e depois da simulação do desafio ácido ocorrido na cavidade bucal. Para a análise de sorção e solubilidade os espécimes foram submetidos a ciclos de hidratação e ressecamento e através da comparação entre as pesagens iniciais e finais foi possível estabelecer os resultados. Os resultados de Rugosidade foram favoráveis às técnicas indiretas (grupos I e II) com médias de Ra=0,141m e 0,181m, respectivamente, seguidos pelas técnicas diretas (grupos III e IV) com Ra=0,373m e 0,908m. Os resultados de porosidade foram de 0,8 poros por área delimitada para o grupo I, seguido do grupo II com 0,9 poros; grupo III com 7,2 poros e grupo IV com 124 poros. Os resultados de microdureza para todos os grupos evidenciaram diminuição da dureza após a ciclagem ácida com valores que diminuíram de 14,12 para 13,03 no grupo I; de 14,06 para 12,93 no grupo II; de 13,73 para 12,71 no grupo III e de 13,47 para 12,65 no grupo IV. Os resultados de sorção foram de 1,807% para o grupo I; 1,817% para o grupo II; 2,068% para o grupo III e 2,227% para o grupo IV. E os resultados de solubilidade foram 0,036% para o grupo I; 0,054% para o grupo II; 0,184% para o grupo III e 0,212% para o grupo IV. Os maiores valores de rugosidade e porosidade foram alcançados pelos corpos-de-prova confeccionados pelas técnicas diretas e os menores valores se deram nos corpos-de-prova confeccionados segundo as técnicas indiretas e pela técnica do pincel. O desafio ácido reduziu a dureza da resina acrílica, porém não houve diferença nos testes de dureza entre os diferentes grupos. Os espécimes confeccionados pelas técnicas indiretas apresentaram menor sorção e solubilidade quando comparadas às técnicas diretas. Portanto, as técnicas indiretas de confecção de coroas provisórias devem ser preferidas às técnicas diretas. / An in vitro evaluation of the influence of three variables (polymerization medium (air/water), temperature and pressure) on roughness, porosity, microhardness, sorption and solubility of an acrylic resin for provisional crowns was conducted according to 4 techniques (direct and indirect). The samples were prepared using a poly (methylmethacrylate) (PMMA) resin Dencor color No 66. The surface roughness (Ra) was evaluated with a perfilometer. Porosity was analyzed according a quantitative method of counting number of pores per area by using a comparator microscope. Microhardness readings were made before and after acid challenge simulation as in the oral cavity. For sorption and solubility analysis, specimens were subjected to successive cycles of dampening and dehydration to make comparisons of the initial and final weights. Roughness results were lower for indirect techniques (groups I and II) with averages of Ra = 0.141m and 0.181m, respectively, followed by direct techniques (groups III and IV) with Ra = 0.373m and 0.908m. Porosity results were 0.8 pores per area for the group I, 0.9 pores for group II, 7.2 pores for group III and 124 pores for group IV. All groups showed a decrease in hardness after acid cycling with values that ranged from 14.12 to 13.03 in group I, 14.06 to 12.93 in group II, 13.73 to 12.71 in group III, and 13.47 to 12.65 in group IV. Sorption results were 1.807% in group I, 1.817% in group II, 2.068% in group III, and 2.227% in group IV. Solubility results were 0.036% in group I, 0.054% in group II, 0.184% in group III and 0.212% in group IV. Higher values of roughness and porosity were obtained by specimens made by direct technique and lower values were achieved with specimens made by indirect technique and brush technique. The acid challenge statistically decreased hardness of the acrylic resin, but there was no statistical difference among different groups. The specimens prepared by indirect techniques showed lower sorption and solubility when compared to direct techniques. The indirect techniques for making provisional crowns should be preferred compared to direct techniques.
86

Exílios portugueses durante a União das Coroas Ibéricas (1604-1605) / Portugueses exiles during the Union of Iberian Crowns (1604-1605)

Rodrigues, Bruno Romano 12 February 2015 (has links)
A presente pesquisa reflete sobre o exílio de letrados portugueses coetâneos durante o espaço temporal que a historiografia convencionou chamar de União das Coroas Ibéricas (1580-1640). Para isso, analisam-se as obras de D. João de Castro (Lisboa, Portugal 1550? - Paris, França 1628?), intitulada Aurora (1604-1605), e de Thomé Pinheiro da Veiga (Coimbra, Portugal 1571? - ?, 1656?), chamada Fastigimia (1604-1605), no intuito de apreender o impacto das experiências vividas por cada um deles nas cidades de Paris, na França, e Valadolide, na Espanha, respectivamente. O estudo se pauta no cotejamento das fontes com as tópicas criadas, na Antiguidade, pelo poeta Ovídio (Sulmo/Sulmona, na atual Itália 43 a.C. - Tomis/Constança, na atual Romênia, 17 ou 18 d.C.). Estabelecendo continuidade com a tradição humanista lusitana, mostra-se como D. João de Castro se valeu da funcionalização da memória por meio de figuras míticas ou históricas, da caracterização disfórica da vida no estrangeiro, e, por fim, da constante oscilação entre esperança e desalento. Thomé Pinheiro da Veiga, por sua vez, manejou, em termos literários, a consciência do tempo e do espaço. Diante deste quadro, conclui-se que o exílio de Castro constituiu uma penitência escatológica de caráter individual e coletivo, enquanto o experienciado por Veiga se pautou por sistemáticas comparações entre dois reinos da Península Ibérica. / This current study thinks over the portuguese scholars exiled during the time period called by historiography as the Union of Iberian Crowns (1580-1640). For this purpose we will examine two literary works: D. João de Castro\'s (Lisbon, Portugal 1550? - Paris, France 1628?) Aurora (1604-1605), and Thomé Pinheiro da Veiga\'s (Coimbra, Portugal 1570 - ? 1656) Fastigimia (1608-1609?), to learn about their experiences, lived by each one, in Paris, France, and Valladolid, Spain, respectively. The study is ruled in contrasting this texts against the themes set up in Classical Antiquity, by roman poet Ovid (Sulmo/Sulmona, nowdays Italy 43 BC - Tomis/Constanta, nowdays Romania, 17/18 AD). Stating continuity with portuguese renaissance humanism tradition, D. João de Castro seems like to resort the Ovidian topics about implementing the memory through mithologycal or historical characters, through marking a twisted foreign life, and, a steady oscillation between hope and discincentive. Thomé Pinheiro da Veiga, by himself, handled, in litteraly terms, a strict awareness about time and space. Keeping this in mind, we can conclude that Castro\'s exile build an eschatological penance with individual and collective nature, while Veiga\'s stands by a methodical comparison amog the two kingdons of Iberian Peninsula.
87

"Avaliação da retenção de coroas metálicas fundidas em função dos tipos de agentes cimentantes e das ciclagens térmica e mecânica" / Evaluation of cast crowns’ retention with two different lutting agents after thermocycling and mechanical load

Nakao, Emerson 18 October 2005 (has links)
Nesta pesquisa, foram avaliados a retenção de coroas cimentadas sobre dentes terceiros molares humanos extraídos, após submetê-los às ciclagens térmica e mecânica, e o tipo de falha dos cimentos. Vinte dentes foram preparados de maneira padronizada, com 4 mm de altura, 8 mm de diâmetro e 20º de expulsividade. Coroas metálicas fundidas em NiCr foram cimentadas sobre os preparos, sendo dez com cimento de fosfato de zinco e dez com cimento resinoso, e armazenadas em água a 37ºC por 24 horas. Aleatoriamente, a metade das amostras de ambos os cimentos foi submetida a termociclagem (5ºC e 55ºC ±1ºC por 700 ciclos), seguida de ensaios mecânicos (freqüência de 2 Hz, carga compressiva de 141N por 200.000 ciclos). A outra metade das amostras (grupo controle) não foi submetida aos testes de fadiga. Realizou-se o teste de tração e os valores obtidos foram tratados estatisticamente pelo teste ANOVA (Tukey-Kramer Multiple Comparisons Test). Os resultados mostraram retenção significativamente superior do cimento resinoso Panavia F (valor médio 569,43 N) sobre o cimento de fosfato de zinco (valor médio 350 N). Os testes de envelhecimentos mostraram-se significantes (p<0,001) na sua influência sobre a retenção das coroas, exceto para o grupo cimentado com fosfato de zinco (p>0,05). A falha do cimento observada foi de natureza adesiva para todos os grupos. / The aim of this study was to evaluate the retention of NiCr cast metal crowns fixed with two different lutting agents after thermocycling and mechanical load. The nature of the cement failure was evaluated too. Twenty natural human molar teeth extracted were selected (Banco de Dentes Permanentes Humanos da Faculdade de Odontologia da Universidade de São Paulo – SP). They were prepared at 4mm height, 8mm diameter and 20º of convergence. The cast crowns were lutted with zinc phosphate cement (n=10) and resin cement (n=10) and stored in water at 37ºC for 24 hours. Randomly the half of the specimens of each cement were thermal (5ºC and 55ºC for 700 cycles) and load cycled (2 Hz, 141 N load for 200.000 cycles). The control group did not perform the thermal or fatigue tests. The pull-out test was performed and the results showed a significant (confidence interval 95%) superior retentive strength for Panavia F resin cement (mean value 569,43 N) when compared with zinc phosphate (mean value 350 N). The aging tests were significant (p<0,001) about their influence over the retention of the crowns. They was no significant difference between control and cycled group for crowns lutted with phosphate cement (p>0,05). Adhesive failure of the cements was observed for all subjects.
88

Influ?ncia do acabamento de preparos para coroas totais com microsc?pio operat?rio na adapta??o marginal de restaura??es em cer?mica tipo CAD-CAM

Oliveira, Jos? Pedro Peixoto de 16 January 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:16Z (GMT). No. of bitstreams: 1 399743.pdf: 674310 bytes, checksum: 694cbc44bc682f21bed71e69a6f99e90 (MD5) Previous issue date: 2008-01-16 / Este estudo teve o objetivo de avaliar a adapta??o de infra-estruturas de cer?mica Lava (3M/ESPE) com tr?s diferentes tipos de acabamento em preparos para coroa total. Trinta pr?-molares humanos, extra?dos por raz?es terap?uticas, foram fixados em blocos de resina acr?lica e divididos aleatoriamente em tr?s grupos (n=10) de acordo com o procedimento para realizar os preparos: grupo 1 - ponta diamantada; Grupo 2 - ponta diamantada e broca multi-laminada; Grupo 3 - ponta diamantada e broca multi-laminada, sendo este ?ltimo instrumento com o uso do microsc?pio operat?rio em aumento de 12,5 vezes. Os preparos foram moldados com silicone por adi??o e os modelos obtidos em gesso especial tipo IV. Os modelos foram enviados para o laborat?rio da 3M/ESPE, o qual confeccionou os casquetes de cer?mica Lava. As infra-estruturas foram cimentadas nos dentes preparados com RelyX Unicem, sendo ent?o inclu?dos em blocos de resina acr?lica e cortados em dois planos: m?sio-distal e vest?bulo-lingual. Desta forma, obteve-se quatro fragmentos, sendo que cada fragmento forneceu duas regi?es para observar a discrep?ncia das margens. Por meio de lupa estereosc?pica, acoplada a uma c?mera de v?deo, foram obtidas imagens digitais da regi?o das margens em aumento de 70 vezes. As medidas de adapta??o marginal foram realizadas no programa Image Tool. De acordo com ANOVA e teste de Tukey (&#945;=0,05), n?o houve diferen?a estat?stica entre os Grupo 1 (88,601 &#956;m) e Grupo 2 (90,946 &#956;m). A menor m?dia foi obtida para o Grupo 3 (58,497 &#956;m), diferindo estatisticamente dos outros dois grupos. P?de-se concluir que o emprego do microsc?pio operat?rio favoreceu a melhor adapta??o marginal nos casquetes de cer?mica Lava.
89

[en] ANALYSIS OF STRESS DISTRIBUTION IN DIFFERENT FINISHING LINES OF SINGLE ALL-CERAMIC CROWNS / [pt] ANÁLISE DA DISTRIBUÇÃO DE TENSÕES EM DIFERENTES TERMINAÇÕES CERVICAIS DE COROAS UNITÁRIAS TOTALMENTE CERÂMICAS

JOSE EDUARDO VASCONCELLOS AMARANTE 28 June 2004 (has links)
[pt] Este estudo apresenta uma análise numérica pelo método de elementos finitos da distribuição de tensões em dentes restaurados com coroas unitárias totalmente cerâmicas de diferentes tipos de terminações cervicais. Para a obtenção do modelo numérico bi-dimensional, três modelos da região de molares inferiores foram criados a partir de uma peça anatômica real e simularam a aplicação de coroas cerâmicas puras com diferentes terminações cervicais no segundo molar. O material selecionado para as restaurações foi uma cerâmica reforçada por dissilicato de lítio, enquanto que as terminações cervicais adotadas foram do tipo ombro reto, ombro arredondado e chanfro. Com o objetivo de realizar uma análise mais criteriosa das distribuições de tensões inerentes aos diferentes tipos de terminações cervicais, optou-se por criar o mesmo modelo em uma condição totalmente hígida, isto é, com ausência de qualquer tipo de restauração. A simulação numérica foi realizada pelo software ANSYS 7.0, sendo os modelos carregados com uma força estática de 400 N distribuída uniformemente na espessura dos dentes e subdividida em pontos de aplicação nas superfícies oclusais dos elementos dentais de acordo com a relação cúspide-crista. Os vetores correspondentes à aplicação das forças foram direcionados para região ânteroinferior da mandíbula com uma angulação de 15o. Os resultados mostraram que a restauração envolvendo a coroa cerâmica com terminação cervical em ombro reto concentrou mais tensões no dente molar restaurado, seguida pela coroa cerâmica com uma terminação cervical do tipo ombro arredondado. Por sua vez, a coroa cerâmica com a terminação cervical em chanfro provocou uma distribuição de tensões mais homogênea no dente molar restaurado. / [en] This work presents a finite element analysis of the stress distribution in teeth restored by single all-ceramic crowns with different types of finishing lines. In order to obtain the 2-D numerical model, three models of the mandibular molar teeth region were created considering a real anatomic piece and were then used to simulate the application of all-ceramic crowns with different finishing lines on the second molar. The selected material for the restorations was a ceramic material reinforced by lithium disilicate and the finishing lines adopted were shoulder, rounded shoulder and chamfer type. Aiming to realize a more careful analysis of the stress distributions associated with the different finishing lines, the same model was created in a completely healthy condition, i. e., in the absence of any kind of restoration. The numerical simulation was carried out by the ANSYS 7.0 software loading the models with 400 N distributed by the teeth thickness and applied according to the cusp-crest relationship at points in the teeth oclusal surfaces. The vectors corresponding to the applied forces were oriented towards the former-inferior mandibular region at the angle of 15o. The results indicated that the restoration involving the all-ceramic crown with the shoulder type finishing line intensified the stress in the restored molar tooth, followed by the all-ceramic crown with the rounded shoulder. On the other hand, the all-ceramic crown with the chamfer type finishing line caused a more homogeneous stress distribution in the restored molar tooth.
90

"Avaliação da retenção de coroas metálicas fundidas em função dos tipos de agentes cimentantes e das ciclagens térmica e mecânica" / Evaluation of cast crowns’ retention with two different lutting agents after thermocycling and mechanical load

Emerson Nakao 18 October 2005 (has links)
Nesta pesquisa, foram avaliados a retenção de coroas cimentadas sobre dentes terceiros molares humanos extraídos, após submetê-los às ciclagens térmica e mecânica, e o tipo de falha dos cimentos. Vinte dentes foram preparados de maneira padronizada, com 4 mm de altura, 8 mm de diâmetro e 20º de expulsividade. Coroas metálicas fundidas em NiCr foram cimentadas sobre os preparos, sendo dez com cimento de fosfato de zinco e dez com cimento resinoso, e armazenadas em água a 37ºC por 24 horas. Aleatoriamente, a metade das amostras de ambos os cimentos foi submetida a termociclagem (5ºC e 55ºC ±1ºC por 700 ciclos), seguida de ensaios mecânicos (freqüência de 2 Hz, carga compressiva de 141N por 200.000 ciclos). A outra metade das amostras (grupo controle) não foi submetida aos testes de fadiga. Realizou-se o teste de tração e os valores obtidos foram tratados estatisticamente pelo teste ANOVA (Tukey-Kramer Multiple Comparisons Test). Os resultados mostraram retenção significativamente superior do cimento resinoso Panavia F (valor médio 569,43 N) sobre o cimento de fosfato de zinco (valor médio 350 N). Os testes de envelhecimentos mostraram-se significantes (p<0,001) na sua influência sobre a retenção das coroas, exceto para o grupo cimentado com fosfato de zinco (p>0,05). A falha do cimento observada foi de natureza adesiva para todos os grupos. / The aim of this study was to evaluate the retention of NiCr cast metal crowns fixed with two different lutting agents after thermocycling and mechanical load. The nature of the cement failure was evaluated too. Twenty natural human molar teeth extracted were selected (Banco de Dentes Permanentes Humanos da Faculdade de Odontologia da Universidade de São Paulo – SP). They were prepared at 4mm height, 8mm diameter and 20º of convergence. The cast crowns were lutted with zinc phosphate cement (n=10) and resin cement (n=10) and stored in water at 37ºC for 24 hours. Randomly the half of the specimens of each cement were thermal (5ºC and 55ºC for 700 cycles) and load cycled (2 Hz, 141 N load for 200.000 cycles). The control group did not perform the thermal or fatigue tests. The pull-out test was performed and the results showed a significant (confidence interval 95%) superior retentive strength for Panavia F resin cement (mean value 569,43 N) when compared with zinc phosphate (mean value 350 N). The aging tests were significant (p<0,001) about their influence over the retention of the crowns. They was no significant difference between control and cycled group for crowns lutted with phosphate cement (p>0,05). Adhesive failure of the cements was observed for all subjects.

Page generated in 0.026 seconds