• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1392
  • 17
  • 16
  • 15
  • 15
  • 15
  • 7
  • 7
  • 7
  • 4
  • 4
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 1431
  • 690
  • 469
  • 306
  • 241
  • 205
  • 197
  • 185
  • 166
  • 158
  • 122
  • 121
  • 116
  • 108
  • 105
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Estudo das propriedades de revestimentos compósitos de níquel com Al2O3 e SiC

Malfatti, Célia de Fraga January 2000 (has links)
Neste trabalho foi avaliada a resistência à corrosão dos revestimentos compósitos de níquel, obtidos a partir de um banho de níquel químico (electroless) e um banho de níquel eletrolítico tipo Watts (com e sem tensoativo), caracterizando-os comparativamente em relação ao revestimento de níquel sem partículas. Os métodos utilizados para avaliação da resistência a corrosão foram: ensaio acelerado em névoa salina, voltametria cíclica, curva de polarização potenciodinâmica (em NaCl 0,6N) e dissolução anódica à corrente constante. Os revestimentos também foram avaliados com relação à resistência ao desgaste, rugosidade, e morfologia da camada. As partículas foram caracterizadas por difração de raio- X , dispersão granulométrica e potencial zeta. Nas condições estudadas os resultados mostraram que o revestimento compósito Ni-P-Al2O3 (Al2O3 - tamanho de grão ≅ 0,1 a 1,8µm) apresentou melhor resistência à corrosão que o revestimento de níquel químico sem incorporação de partículas (Ni-P) que por sua vez, apresentou resistência a corrosão superior ao compósito Ni-P-SiC no. 23 (SiC no. 23 - tamanho de grão ≅0,8 a 19,9µm). Já o eletrodepósito de níquel sem incorporação de partículas apresentou melhor resistência à corrosão que os revestimentos compósitos. Entre estes o compósito Ni-Al2O3 apresentou resistência a corrosão superior ao compósito Ni-SiC no. 23 A adição do tensoativo lauril sulfato de sódio reduz a quantidade de partículas incorporadas no eletrodepósito, sendo este efeito mais acentuado para o SiC com maior granulometria. Para diferentes granulometrias de carbeto de silício (SiC no. 2 - tamanho de grão ≅0,3 a 6,2µm e SiC no. 23 - tamanho de grão ≅0,8 a 19,9µm), o revestimento compósito obtido com o SiC que possui menor granulometria, apresentou maior resistência à corrosão e maior resistência ao desgaste, indicando desta forma que o tamanho da partícula incorporada no depósito de níquel exerce grande influência sobre a resistência à corrosão do revestimento, bem como sobre a resistência ao desgaste.
212

Eletrosíntese de filmes de polímeros a partir de naftilaminas substituídas sobre metais oxidáveis e síntese química : aplicação na proteção contra a corrosão

Meneguzzi, Alvaro January 2000 (has links)
Neste trabalho é apresentado um estudo da síntese e caracterização de polinaftilaminas substituídas com vistas à sua utilização na proteção contra a corrosão. É mostrada a possibilidade de eletrosíntese de filmes destes polímeros intrinsecamente condutores sobre metais oxidáveis passiváveis em meio aquoso ácido pelos métodos potenciostático e potenciodinâmico sem dissolução dos eletrodos. A caracterização química, morfológica e eletroquímica destes filmes poliméricos demonstrou que não há sensíveis diferenças em relação aos mesmos filmes obtidos sobre eletrodos inertes e que é preservada uma das funções na cadeia polimérica. Os filmes de naftilaminas substituídas oferecem uma barreira parcial contra a corrosão do aço carbono e quando polimerizado o 1,5-diaminonafttaleno juntamente com a anilina forma-se o compósito Poli 1,5-diaminonaftaleno/Polianilina que passiva anódicamente o Fe em meio sulfato pH 4. É apresentada também a síntese química do poli 5-amino 1-naftol, que se mostra passivante anódico do aço inox SS 430 em ácido sulfúrico aquoso 1M.
213

Contribuição ao estudo da carbonatação em concretos e argamassas compostos com adição de sílica ativa

Kulakowski, Marlova Piva January 2002 (has links)
As adições pozolânicas vêm sendo adicionadas ao concreto com o objetivo de melhorar as características de resistência mecânica e de durabilidade. Entre estas adições encontra-se a sílica ativa, resíduo oriundo da produção de ligas a base de silício. A sílica ativa apresenta como características alta reatividade, tamanho reduzido das partículas e alta superfície específica, agindo no concreto de duas maneiras: transformando o Ca(OH)2 em C-S-H e densificando a matriz de cimento. Apresenta como efeitos benéficos o aumento da resistência mecânica e redução da penetração de íons cloreto e água. Contudo, em função do consumo de Ca(OH)2, o pH da fase líquida dos poros é reduzido, o que pode prejudicar o comportamento do concreto em relação à carbonatação, existindo uma polêmica em torno do assunto. Desta forma, o presente trabalho teve por objetivo estudar aspectos de porosidade e aspectos químicos do comportamento da sílica ativa, em concretos e argamassas, em relação à carbonatação. Para tanto empregou-se relações água/aglomerante entre 0,35 e 0,80 e teores de adição de sílica ativa, em relação à massa de cimento, até 20%. Os resultados indicam um comportamento distinto das adições conforme a relação água/aglomerante Até o limite de 0,45-0,50, a carbonatação nestes materiais é regida pela porosidade e o consumo de Ca(OH)2 não apresenta efeitos significativos na carbonatação e, a partir deste limite, o consumo de Ca(OH)2 passa a ser significativo. Paralelamente, foi estudada resistência à compressão e absorção de água. A relação entre profundidade de carbonatação com estas propriedades apresenta uma correlação direta apenas para os concretos sem adição.
214

Estudo da capacidade de proteção de alguns tipos de cimentos nacionais, em relação à corrosão de armaduras sob a ação de íons cloreto

Tessari, Ricardo January 2001 (has links)
O concreto normalmente oferece um alto grau de proteção contra a corrosão ao aço, devido à formação de uma fina película protetora na sua superfície, causada pela alta alcalinidade do concreto. Entretanto, essa película pode ser rompida tanto pela diminuição do pH da solução dos poros do concreto (por carbonatação, por exemplo) ou pela penetração de íons agressivos (como cloretos, por exemplo) até a superfície do aço. O presente trabalho tem por objetivo comparar o desempenho de concretos feitos com diferentes tipos de cimento Portland normalizados no Brasil frente à ação de íons cloreto provenientes de fontes externas. O programa experimental foi realizado com cinco diferentes tipos de cimento (CPII-E, CPII-F, CPIV, CPV ARI e CPV ARI-RS), com e sem adições, e cinco relações água/aglomerante (0,30; 0,35; 0,45; 0,60 e 0,80) em ensaios acelerados de despassivação por cloretos, por meio de ciclos de imersão e secagem dos corpos-de-prova em solução contendo 3,5% de cloreto de sódio. O método de Potencial de Eletrodo foi utilizado para monitorar a corrosão ao longo do tempo. Paralelamente foram realizados ensaios de resistência à compressão do concreto aos 28 dias, de perda de massa da armadura e de teor de cloretos livres no cobrimento da armadura. Os resultados obtidos mostraram que a escolha do tipo de cimento tem influência tanto na resistência à compressão simples quanto na resistência à corrosão das armaduras, verificada através dos ensaios de potencial de eletrodo, de perda de massa gravimétrica da armadura e de teor de cloretos livres. No entanto não houve um tipo de cimento que apresentasse os melhores resultados para todos os tipos de ensaio. / Concrete usually provides a high level of protection against steel corrosion, due to the formation of a fine protecting film on its surface, caused by concrete alkalinity. However, this film can be torn both as a result of the decrease in the pH of the solution of the concrete pores (by carbonation, for example) or as a result of the penetration of aggressive ions (such as chlorides, for example) up to the surface of the steel. The present work has the objective of comparing the performance of concrete made with different kinds of Portland cement regulated in Brazil before the action of chloride ions derived from external sources. The experimental program was performed with five different types of cement (CPII-E, CPII-F, CPIV, CPV ARI and CPV ARI-RS), with and without additions, and five water/agglomerative relations (0.30; 0.35; 0.45; 0.60 and 0.80) in acceleration assays of inactivation by chlorides, by means of immersion cycles and drying of proof bodies in a solution contained 3.5% of sodium chloride. The method of Electrode Potential was used to monitor corrosion over time. Concomitantly, resistance tests were performed as to the compression of the concrete at 28 days, from the loss of mass of the armature and content of free chlorides in the armature coating. The results obtained showed that the selection of the kind of cement has an impact both on the simple compression resistance and on the resistance to armature corrosion, verified through tests of electrode potential, of armature gravimetric mass loss and free chloride content. However, there was not a kind of cement presenting the best results for all types of assay.
215

Caracterização polifásica de micro-organismos isolados de superfícies metálicas na Usina Hidrelétrica de Tucuruí, Pará, Brasil

Poitevin, Carolina Gracia January 2014 (has links)
Orientadora : Profª Drª Patricia do Rocio Dalzoto / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências Biológicas, Programa de Pós-Graduação em Microbiologia, Parasitologia e Patologia Básica. Defesa: Curitiba, 28/03/2014 / Inclui referências / Área de concentração: Microbiologia / Resumo: A corrosão influenciada por micro-organismos (CIM) é a mudança do potencial eletroquímico na interface metal/solução, causado pela produção de metabólitos de bactérias e fungos que crescem aderidos a superfícies metálicas na forma de biofilmes. O conhecimento da microbiota dos biofilmes permite a escolha do melhor antimicrobiano a ser utilizado para reduzir os efeitos da CIM. A abordagem polifásica, que consiste na associação de técnicas morfológicas, químicas e genéticas, é interessante para uma correta caracterização de micro-organismos. A espectroscopia no infravermelho aparece como uma opção para a identificação de fungos e bactérias devido à rapidez na execução e ao menor custo, quando comparado com as demais técnicas. O objetivo deste trabalho foi o isolamento e a identificação polifásica de micro-organismos presentes em corpos de prova metálicos instalados na Usina Hidrelétrica de Tucuruí (PA), e a avaliação do melhor biocida a ser utilizado para o controle da formação de biofilmes. As coletas foram feitas a cada dois meses entre 2011 e 2012, e os micro-organismos identificados por macro e micromorfologia, bioquimismo e biologia molecular. Os antimicrobianos Orobor, MXD-100 (MaxClean®), hidróxido de sódio, extrato de aroeira (Schinus terebinthifolius) e extrato de erva-mate (Ilex paraguariensis) foram testados quanto a sua eficiência. Os dados foram analisados por ANOVA (p<0,01) seguido por teste de Scott-Knott para comparação das médias (p<0,05). Foram isoladas 358 bactérias aeróbias ou anaeróbias facultativas, pertencentes em sua maioria aos gêneros Bacillus, Citrobacter, Shigella, Pseudomonas, Enterobacter e Acinetobacter. Foi verificada a presença de bactérias redutoras de sulfato e bactérias oxidantes de ferro, além do isolamento de 94 fungos, com predomínio dos gêneros Penicillium e Aspergillus. Os antimicrobianos MXD-100 1 ppm e 3 ppm, Orobor 10 mL/L e NaOH pH 14 foram os mais eficientes no controle, reduzindo em aproximadamente 35% o crescimento bacteriano e fúngico. A espectroscopia no infravermelho foi testada para classificação microbiana, e se mostrou eficiente na identificação de fungos filamentosos, mas novas metodologias devem ser testadas para a identificação bacteriana. A caracterização de micro-organismos encontrados nos corpos de prova metálicos mostra a biodiversidade da região e está relacionada ao processo de biocorrosão, possibilitando o desenvolvimento de novas estratégias de controle. Palavras chave: Biofilme, biocorrosão, biocida e NIRS. / Abstract: Microbially Influenced Corrosion (MIC) is the change of electrochemical potential at the interface metal/solution, caused by metabolites produced by bacteria and fungi growing in metallic surfaces as biofilms. The knowledge of biofilms’ microbiota allow us to choose the best biocide to reduce the effects of MIC. Polyphasic approach, consisting in associate morphological, chemical and genetical techniques, is interesting for the correct characterization of micro-organisms. Infrared spectroscopy shows up as an option to identify fungi and bacteria because of faster response and lower costs, when compared with other techniques. The aim of this work were the isolation and the polyphasic identification of micro-organisms present in metallic coupons installed in Tucuruí’s Power Plant (PA), and the evaluation of the best biocide to be used for the control of biofilm formation. Samples were collected every two months during 2011 and 2012, and micro-organisms were identified by macro and micromorphology, biochemical assays and molecular tools. The efficiency of biocides Orobor, MXD-100 (MaxClean®), sodium hydroxide, Schinus terebinthifolius extract and Ilex paraguariensis extract were tested. Data were analyzed by ANOVA (p<0.01) followed by Scott-Knott test for comparison of means (p<0.05). It was isolated 358 aerobic or facultative anaerobic bacteria, belonging mostly to the genera Bacillus, Citrobacter, Shigella, Pseudomonas, Enterobacter and Acinetobacter. Sulfate-reducing and iron-oxidizing bacteria were also found, in addition of isolation of 94 fungi, with prevalence of the genera Penicillium and Aspergillus. MXD-100 1 ppm and 3 ppm, Orobor 10 mL/L and NaOH pH 14 were the most efficient biocides, reducing approximately 35% of bacteria and fungi. Infrared spectroscopy was tested for micro-organisms classification, and it was efficient to identify filamentous fungi, but new methodologies need to be tested to bacterial identification. The characterization of micro-organisms found on metal surfaces highlights the biodiversity of the region and can be related to the process of biocorrosion, enabling the development of new strategies for its control. Key words: Biofilm, biocorrosion, biocide and NIRS.
216

Estudo da resistência ao desgaste e à corrosão de revestimentos metálico-cerâmicos aplicados na liga AA7050 mediante aspersão térmica oxicombustível de alta velocidade (HVOF) /

Magnani, Marina. January 2008 (has links)
Resumo: Nesse trabalho, para melhorar a resistência à corrosão e ao desgaste das ligas de alumínio AA7050, foram obtidos revestimentos metálico-cerâmicos por aspersão térmica em alta velocidade (HVOF). As propriedades estruturais, de resistência ao desgaste e à corrosão da liga AA7050 e dos revestimentos de WC-Co, Cr3C2-NiCr e WC-Co foram estudadas por medidas eletroquímicas em NaCl 3,5% e medidas de desgaste. Os revestimentos foram caracterizados por microscopia óptica (OM), microscopia eletrônica de varredura (SEM) e difratometria de raios X (XRD). As resistências ao desgaste por abrasão e fricção foram estudadas por ensaios de Rubber Wheel e Ball On Disk. Os estudos eletroquímicos foram conduzidos por medidas de potencial de circuito aberto, espectroscopia de impedância eletroquímica e curvas de polarização. Estudou-se também a influência da temperatura da chama da pistola, nas mesmas condições de preparação dos revestimentos, aplicada sobre a liga de alumínio usando técnicas eletroquímicas e análises microscópicas: OM; SEM e microscopia eletrônica de transmissão (TEM). Os revestimentos foram aspergidos sem e com um sistema de refrigeração usando nitrogênio líquido e sob diferentes condições de aspersão (condições padrão, aumentando o fluxo de oxigênio e de ar comprimido). As diferenças encontradas nos revestimentos foram relacionadas com a variação desses parâmetros de aspersão térmica. Quanto à resistência ao desgaste não se observou diferenças significativas para os revestimentos e todos apresentaram velocidades de desgaste cerca de 10 vezes menores do que a liga AA7050. Já em relação à corrosão, os revestimentos de Cr3C2-NiCr apresentam maiores resistências que os revestimentos de WC-Co (Cr). A refrigeração do substrato durante a aspersão térmica melhorou significativamente a resistência a corrosão dos revestimentos em meio de NaCl 3,5%. / Abstract: In this work, HVOF (high velocity oxygen fuel) technique was used to apply metallic-ceramic coatings on an AA7050 aluminum alloy to improve its corrosion and wear resistance. Structural, wear and corrosion resistance properties of the AA7050 aluminum alloy and WC-Co, Cr3C2-NiCr and WC-Co metallic-ceramic coatings were studied using electrochemical and wear measurements. The morphology and microstructure of the coatings were characterized using optical (OM) and scanning electron microscopy (SEM), and X-ray diffraction (XRD). The friction coefficient and abrasive wear resistance of the coatings were measured using Rubber Wheel and Ball on Disk tests. The electrochemical studies were conducted using open-circuit potential (EOC) measurements, electrochemical impedance spectroscopy (EIS) and polarization curves. The influence of the flame of the gun at the same condition used for coatings preparation, on AA7050 aluminum alloy was also studied using electrochemical measurements and OM, SEM and TEM-transmission electron microscopy analysis. The metallic-ceramic coatings were sprayed on AA7050 alloy using or not a liquid nitrogen cooling prototype system. The coatings were sprayed using different thermal spray conditions (standard conditions, increasing the oxygen flux and increasing the carrier gas flux). Differences among coated samples were mainly related with the variation of the thermal spray parameters used during the spray process. No significant differences were observed in the wear resistance for all the coatings studied, and all of them showed a wear rate around 10 times lower than the aluminum alloy. The Cr3C2-NiCr coating showed higher corrosion resistance than WC-Co (Cr) coatings. The refrigeration of the substrate with liquid nitrogen during the thermal spray process increased the corrosion resistance of the coatings in NaCl 3.5%. / Orientador: Assis Vicente Benedetti / Coorientador: Cecílio Sadao Fugiwara / Banca: Antonio Tallarico Vicente Adorno / Banca: Isolda Costa / Banca: Carlos Roberto Camello Lima / Banca: Zeki Naal / Doutor
217

Validação do método de queda de potencial para medição do comprimento de trinca em corpos de prova tipo SENB com trinca curta em ensaios de propagação de trinca por fadiga

Diehl Neto, Bruno January 2014 (has links)
Os ensaios de propagação de trinca por fadiga em meios corrosivos apresentam um desafio para os laboratórios, onde os métodos de medição mais utilizados (e.g. Medidor de Propagação de Trinca e Clip Gauge) para a medição do comprimento da trinca, se deterioram. O método de Queda de Potencial (QP) pode ser uma alternativa viável e de boa precisão para este propósito, porém deve ser demonstrado que o laboratório tem capacidade de obter elevada precisão e acurácia através do método. Este trabalho tem o objetivo principal de avaliar uma metodologia para a determinação do comprimento de trinca curta durante ensaios de fadiga para caracterização das propriedades de materiais utilizados como dutos de coleta na indústria do petróleo em ambientes corrosivos. Os demais objetivos são: · Consolidar o método de QP para o monitoramento do comprimento da trinca em Corpo de Prova (CP) tipo SENB com trinca curta; · Apresentar as curvas ao ar de propagação de trinca da/dN x ΔK obtidas em ensaios nos materiais 13Cr5Ni2Mo, 25Cr7Ni e API 5L X60; · Identificar melhorias no procedimento dos ensaios para elevar a precisão e acurácia das curvas de taxa de propagação de trinca. Foram realizados ensaios de propagação de trinca em três aços diferentes, isto é, inoxidáveis Supermartensítico e superdúplex e Aço Carbono, sendo registrados os dados do Medidor de Propagação de Trinca (gabarito) e da técnica de QP (método a ser avaliado). Foram validadas as equações necessárias para determinar o tamanho de trinca do CP em função da diferença de potencial transversalmente à trinca com o Medidor de Propagação de Trinca e foram apresentadas as curvas ao ar de taxa de propagação de trinca x ΔK dos materiais estudados. Foi observada uma forte correlação entre os dois métodos de medição de trinca. Acreditamos que as pequenas diferenças observadas nos valores de tamanho de trinca entre as duas técnicas se devem, principalmente à: · Efeito de tunelamento na frente da trinca, já que cada método mede a trinca em diferentes regiões do CP; · Imprecisões na distância do ponto na soldagem dos fios do multímetro (que mede o potencial para técnica de QP) à trinca. As curvas de propagação de trinca foram similares à curva de dois estágios para aços da norma BS 7910 (R ≥ 0,5) na maior parte da curva. Entretanto, em ΔK próximos a 15 MPa.m1/2 (faixa inicial de ΔK aplicado), os aços apresentaram taxas de propagação significativamente inferiores à curva da norma. Foram indicados possíveis motivos para os desvios da curva e sugeridas melhorias nos procedimentos dos ensaios para elevar a precisão e acurácia na obtenção das curvas da/dN x ΔK. / Fatigue crack growth rate (FCGR) tests in corrosive environments are a challenge for laboratories, where the most used techniques (e.g. Clip Gage and Crack Propagation Sensor) for crack size measurements, deteriorate. Potential Drop (PD) technique is a high precision viable alternative, however, it must be demonstrated that the laboratory has capacity to obtain high precision and accuracy through the method. This study has the main objective of evaluate a methodology to determine the short crack size during fatigue tests to properties chacacterization of materials used as oil gathering pipes in the oil and gas industry in corrosivive environment. The other objectives are: · Consolidate the PD technique for crack size monitoring in short crack SENB specimen configurations; · Introduce the 13Cr5Ni2Mo, 25Cr7Ni and API 5L X60 crack propagation rate curves (da/dN x ΔK) tested in air; · Identify test procedures improvements to enhance precision and accuracy of FGCR test curves. FCGR tests were performed in three different steels, i.e. Supermartensitic, Superduplex and Carbon Steel, where Crack Propagation Sensor (template) and PD technique (evaluated method) data were registered. Equations to determine specimen crack size in function of the potential difference measured transversally to the crack were validated with the Crack Propagation Sensor and FCGR curves in air for the studied materials were presented. A strong correlation between both crack size measurement techniques was observed. It is believed that small differences in measured crack size between techniques are mainly due to: · The tunneling effect in the crack front, both methods measuring the crack in different specimen regions · The imprecisions in the distance of the welding point of the multimeter wires used in PD to the crack. The FCGR curves behavior were similar to the two stage curve in air (R ≥ 0.5) from BS 7910 standard for the most of the curve. However, when ΔK was close to 15 MPa.m1/2 (initial applied ΔK range), the steels presented significantly lower propagation rate compared to the standard curve. It was pointed out possible reasons for this deviation and tests procedures improvements were suggested in order to increase FCGR test precision and accuracy.
218

Tinta inteligente na proteção anódica de aço carbono

Silva, Rodrigo Sanchotene January 2016 (has links)
A proteção anódica de metais tem como característica a formação de óxidos protetores insolúveis na superfície, o que resulta na passivação do metal, e consequentemente na desaceleração do processo corrosivo. O uso de polímeros intrinsecamente condutores (PIC), como a polianilina (PAni), tem-se apresentado como alternativa de revestimentos ou componente de revestimentos com propriedades anticorrosivas, devido às suas propriedades eletroquímicas de formação de par redox em interfaces metal/revestimento/eletrólito, que podem induzir o efeito de proteção anódica em metais passiváveis. Devido à dificuldade de dissolução da PAni em solventes para a formação de filmes poliméricos, foi formulado neste estudo um binder, formado pela mistura de PAni no estado oxidado e desdopado, com o plastificante não dopante 4-cloro-3-metilfenol e solvente, que foi adicionado à três tintas e uma resina comercial pelo método de moagem ou dispersão em alta rotação na concentração de 1%. As tintas produzidas foram caracterizadas por métodos físico-químicos e morfológicos que apresentaram resultados que indicam um revestimento em que a PAni está em parte na forma de resina e outra parte dispersa como pigmento, com a preservação das principais funções e características desejáveis da PAni para aplicação como revestimento anticorrosivo. Os ensaios eletroquímicos realizados com a exposição dos revestimentos aplicados sobre aço carbono em meio em que esse é passivável, ofereceram respostas que indicam que é possível a passivação e/ou manutenção da passivação do metal de interesse, fazendo com que este se comporte de forma mais nobre, a partir do uso de PAni EB na forma de binder. Estes resultados representam a ação da proteção anódica sem a necessidade da aplicação de uma corrente externa. / The anodic protection of metals has as a characteristic the formation of protective insoluble oxides on the surface, which results in the passivation of the metal, and consequently in the deceleration of the corrosive process. The use of intrinsically conductive polymers (ICP), such as polyaniline (PAni), has been presented as an alternative coatings or coating component with anticorrosive properties, due to its electrochemical properties of redox pair formation in metal/coating/electrolyte interfaces, which can induce the anodic protection effect on passivable metals. Due to the difficulty of dissolving PAni in solvents for the formation of polymerics films, it was formulated in this study a binder, formed by a mixture of PAni in the oxidized and desdoped state, with the plasticizer non-doping 4-chloro-3-methylphenol and solvent, which was added to the three paints and a commercial resin by high speed milling or dispersing method in concentation of 1%. The paints produced were characterized by physico-chemical and morphological methods that showed results indicating a coating in which the PAni is partly in the form of resin and the other part dispersed as a pigment, keeping the main functions and desirable characteristics of PAni for application as an anticorrosive coating. The electrochemical tests carried out with the exposition of the coatings applied on carbon steel, in a medium in which it is passivable, offered answers that indicate that it is possible to induce and keep the passivation of the metal substrate, so that it behaves in a way more noble, from the use of PAni EB in the form of binder. These results represent the action of the anodic protection without the necessity of an external current application.
219

Estudo da corrosão localizada do magnésio puro e da liga AZ91 HP em soluções contendo cloreto

Weber, Cristina Rejane January 2000 (has links)
A proposta deste trabalho foi analisar e comparar 1) a resistência à corrosão localizada do magnésio puro (Mg, 99,9+%) e 2) da liga de magnésio industrialmente mais usada, AZ91 HP, na presença de íons cloretos. Especial atenção foi dada ao desprendimento de hidrogênio, associado a este processo corrosivo, tanto dentro como fora dos pites. Complementarmente, analisou-se um caso prático da corrosão localizada da liga AZ91 HP, o qual é apresentado como apêndice, verificada em carcaças de motoserra. Para estas análises foram realizados testes eletroquímicos em soluções de NaCI com diferentes concentrações e valores de pH, verificando-se a influência destes parâmetros e da preparação da superfície (lixada ou polida), neste processo de corrosão localizada, tanto no magnésio puro, como com elementos de liga A morfologia do ataque corrosivo, em condições estacionárias (galvanostáticas) com tempo controlado e após varredura potenciodinâmica foram analisadas em Microscópio Eletrônico de Varredura (MEV). No entanto, devido ao acúmulo de produtos de corrosão na cavidade do pite, verificou-se apenas a sua forma macroscópica impedindo uma visão mais detalhada do interior do pite. Nos testes potenciodinâmicos, observou-se também o filme de óxido formado sobre a superfície do metal. Foram realizados, testes volumétricos de determinação da corrente de redução do hidrogênio tanto para o Mg puro quanto para a liga AZ91 HP. Procedeu-se assim, entre Mg e AZ91 HP, a uma comparação da fração de corrente utilizada na redução do hidrogênio e na dissolução do magnésio, expressa através da constante "K". Foi encontrado para "K" valores em torno de 1 para o Mg puro e em torno de O, 12 para a liga AZ91 HP, para uma concentração 1M de NaCI.Para o caso de corrosão em serviço, foi verificado a existência de corrosão por pite, devido à presença de cloretos (Cr) na superfície da liga. Como o sódio não foi encontrado, isto indica uma contaminação por cloreto de magnésio (MgCI2), que provém eventualmente dos fluxos protetores utilizados na fusão da peça. O Mg e MgCI2 líquidos, tem densidade semelhante, a qual facilita o arraste, mas sua decantação posterior na superfície das peças provoca intensa corrosão localizada pelo cloreto quando a umidade for absorvida. / The purpose of this work was to compare the corrosion behavior of pure magnesium (99.9+%) and its industrialy most used alloy, "AZ91 HP", in the presence of chloride íons, which cause pitting corrosion. Moreover, the rate of hydrogen evolution (inside and outside the pits) acompanying this corrosion process, was determined. In addition, a practical case of corrosion of the alloy "AZ91 HP" in chloride was analysed. For these analysis electrochemical tests were accomplished in NaCI solutions of different concentrations and pH values. For both materiais the influence on corrosion behaviour and pitting potential of chloride concentration, pH, surface quality (sanded or polished) and composition was analysed. The corrosion morphology of galvanostatic and potentiodynamic tested samples was observed in Scanning Electron Microscope. However, due to the great amount of corrosion products in the pit cavity, only the macroscopic form of the attack can be verified not allowing a detailed vision of the inside of the pit. In the potentiodynamic tests, the oxide film formed on the surface of the metal could also be observed Volumetric tests for the determination of the H2 evolution current were performed, for pure Mg and for the alloy AZ91 HP, allowing a comparison between these materiais, referring to the value of the constant "K''. This constant is the ratio between the cathodic current of hydrogen evolution and the anodic current of Mg dissolution inside the pits. Values about 1 for pure Mg and about 0.12 for the alloy AZ91 HP in 1M NaCI solutions were determined.The case of corrosion of AZ91 HP in service was identified as localized corrosion attack due to the presence of chloride on the alloy's surface. Since sodium was not detected, this indicates a contamination by magnesium chloride originating from the protective flow used to cover the molten metal. Due to their similar density the MgCI2 flux is easily mingled with the liquid Mg, during the pouring of the mold. Suceeding decantation of MgCI2 to the surface, will cause intense chloride attack when humidity is absorbed.
220

Influência do teor de água na corrosão por pites do alumínio em soluções de ácido fórmico-água e etanol-água contendo cloreto

Darsie, Francis Regina Farret January 1999 (has links)
A proposta do presente trabalho é a análise da influência da atividade da água nos eletrólitos no processo de corrosão por pite do alumínio puro. A importância do estudo da atividade de água é dada pelo fato desta atuar diretamente na solubilidade de sais, na condutividade dos eletrólitos e na formação de óxidos protetores. Portanto , a concentração de H2O altera as propriedades do eletrólito no interior do pite e, conseqüentemente, a cinética do ataque localizado do alumínio também pode ser alterada. Para esta análise foram realizados testes potenciodinâmicos e galvanostáticos utilizando soluções nas quais a atividade de água foi reduzida pela adição de álcool etílico ou de ácido fórmico. Além destes testes, foram feitas medidas de condutividade e de solubilidade de NaCl nos eletrólitos. As amostras ensaiadas foram observadas em microscópio eletrônico de varredura, para a análise da morfologia da corrosão. Em todo o intervalo de concentrações de H2O estudado foi constatada a corrosão por pites cristalográficos. Verificou-se que a atividade de água influi marcantemente no potencial de pite e, também, na morfologia deste tipo de ataque. / The aim of the present work was to analyze the influence of the activity of water in the electrolyte on the pitting corrosion of pure aluminum. The water activity study is important, due to the fact that water acts directly on the solubility of salts, conductivity and oxide film formation. The H20 concentration changes the properties of pit electrolyte and so the kinetic of localized aluminum dissolution could be also altered. For this analysis potentiodynarnic and galvanostatic tests were accomplished using solutions, in which the activity of water was reduced by the addition of ethyl alcohol or of formic acid. Besides these tests, the conductivity and the solubility of NaCl in the electrolytes were determined. The corroded samples were observed in scanning electron microscope. For all studied water concentrations, the samples corroded by the formation of crystallographic pits. It was verified that the activity of water has a significant influence on the pit potential and also on the morphology of this corrosion type.

Page generated in 0.0307 seconds