1

Nouvelles fonctions interrupteurs intégrées pour la conversion d'énergie

Caramel, Christian 27 April 2007 (has links) (PDF)
Les systèmes de conversion de l'énergie électrique sont présents dans beaucoup de domaines de la vie quotidienne. On peut citer le secteur du transport, l'électronique grand public, la médecine, et la distribution de l'énergie. Une défaillance dans une application est le plus souvent ressentie comme étant liée à l'électronique. Adjoignons à cela des besoins en énergie grandissants et une évolution vers une plus grande mobilité, il devient aisé de déduire que les systèmes de conversion de l'énergie modernes doivent êtres plus compacts, plus fiables et plus performants. L'intégration en électronique de puissance est une réponse adéquate à ces problématiques tant elle vise à fiabiliser, à miniaturiser et à améliorer les performances des fonctions de conversion de l'énergie. Les travaux de recherche présentés dans cette thèse traitent de ma contribution à l'amélioration de la fiabilité et des performances d'un composant de puissance largement usité : l'Insulated Gate Bipolar Transistor. Pour cela l'association de deux IGBT aux caractéristiques différentes pour réaliser une architecture dite " faibles pertes " est présentée. Son concept est explicité, son intérêt exposé et son intégration monolithique détaillée. Dans un deuxième temps, une structure de protection monolithiquement intégrable contre les courts-circuits est dévoilée. Son fonctionnement et sa conception en vue de son intégration monolithique sont exposés.
2

Corrosion en eau supercitrique : Apport à la compréhension des mécanismes pour des alliages Fe-Ni-Cr de structure c.f.c

Payet, Mickaël 28 June 2011 (has links) (PDF)
L'eau supercritique peut être utilisée comme caloporteur à haute pression pour améliorer le rendement des centrales électriques. Pour un concept de réacteur nucléaire, la durée de vie des matériaux est un paramètre important en termes de sécurité. Par conséquent, les critères de sélection des matériaux pour un concept de réacteur à l'eau supercritique concernent les propriétés mécaniques à haute température pour une bonne tenue au fluage et à l'irradiation mais également une résistance à la corrosion généralisée et à la corrosion sous contrainte. Ce travail à pour objectif d'améliorer la compréhension des mécanismes de corrosion en eau supercritique à 600°C et 25 MPa pour des alliages c.f.c contenant du fer, du nickel et du chrome. Des essais de corrosion ont été réalisés sur des autoclaves échantillons d'alliages 316L et 690 en prenant en compte l'état de surface. Les couches d'oxydes formées ont été décrites en termes de morphologie, de composition et de structure, après caractérisations par microscopie électronique à balayage, par spectroscopie à décharge luminescente et par diffraction des rayons X. Si un comportement de type gazeux de l'eau supercritique est attendu dans les conditions d'essai, les résultats montrent une dissolution significative de certains éléments de l'alliage. Par conséquent, la corrosion en eau supercritique peut être considérée comme similaire à la corrosion aqueuse avec un effet de la température qui peut influencer la diffusion en phase solide par exemple. Pour l'alliage 690, la couche d'oxyde protectrice formée sur une surface polie est composée de chromine et surmontée d'un chromite ou d'un spinelle mixte de nickel et de fer. La double couche d'oxyde formée sur une surface de même finition pour l'alliage 316L semble moins protectrice. La couche externe de magnétite est poreuse et la couche interne riche en chrome est non homogène. Pour chaque alliage, l'étude des mécanismes de diffusion, grâce à des expériences utilisant des marqueurs ou des traceurs, révèle une croissance de la couche d'oxyde contrôlée par un processus anionique. Cependant, l'état de surface influence fortement les mécanismes de formation des couches d'oxyde. La comparaison des résultats sur l'acier suggère qu'il y a une concurrence entre l'oxydation du fer et celle du chrome. Une quantité suffisante de chrome est nécessaire pour former une fine couche d'oxyde protectrice. Les surfaces très déformées ou à microstructure à grains très fins conduisent à des fines couches d'oxyde de chrome, grâce à une forte densité de site de germination ou grâce aux courts-circuits de diffusion du chrome. L'état de surface est donc déterminant pour l'acier mais le même paramètre engendre des effets différents pour l'alliage à base de nickel. Les surfaces usinées deviennent sensibles à une oxydation interne du chrome, même si une fine couche d'oxyde continue et riche en chrome et manganèse se forme. Ce phénomène suggère une diffusion accélérée concurrentielle entre l'oxygène et le chrome. Pour conclure, ce travail propose un mécanisme de croissance de la couche d'oxyde dans chaque cas et discute des conditions favorables à la formation d'une couche d'oxyde protectrice riche en chrome dans l'optique d'une application au réacteur à eau supercritique.
3

Intégration des fonctions de protection avec les dispositifs IGBT

Legal, Julie 20 April 2010 (has links) (PDF)
La fiabilité et la disponibilité des systèmes de gestion de l'énergie sont les conditions de base pour la généralisation de solutions électriques dans de nombreuses applications. Les dispositifs de puissance doivent être performants non seulement en régime normal, mais aussi en régimes extrêmes, par exemple lors des courts-circuits. Pour cela, les interrupteurs de puissance sont associés de façon discrète à des systèmes de détection et de protection. Une solution pour améliorer la fiabilité des dispositifs consiste à intégrer monolithiquement, au sein d'une même puce, l'interrupteur et les fonctions de détection et de protection. Ces dispositifs intégrés exploitent les interactions électriques qui apparaissent dans la puce pour détecter la défaillance et ainsi la stopper. L'interrupteur de puissance est ainsi protégé et se remet en conduction une fois la défaillance corrigée. Les composants de puissance seront ainsi capables de se protéger lors d'une défaillance. L'objectif de cette thèse est de proposer des solutions d'intégration de fonctions de protection et de diagnostic rapprochées avec les dispositifs IGBT afin d'augmenter la fiabilité et la disponibilité des systèmes de puissance. Les fonctions de protection sur lesquelles nous nous sommes focalisés sont le miroir de courant ("Sense") et le capteur d'anode ("Capteur de Tension d'Anode") pour détecter les courts-circuits. Ces deux capteurs ont été étudiés à l'aide de simulation 2D puis réalisés technologiquement. Un circuit de détection et de protection des IGBT contre les courts-circuits, comprenant le capteur de tension d'anode intégré monolithiquement, est proposé et simulé. Les tests électriques des capteurs en mode statique permettent de mieux comprendre leur comportement. Enfin, l'interrupteur IGBT associé à ses fonctions de détection et de protection est testé de manière discrète dans un circuit de commutation en condition de court-circuit afin de valider le fonctionnement.
4

Etude de régulateurs linéaires et à découpage intégrés : Application à la téléphonie portable

Hamon, Cécile 27 September 2001 (has links) (PDF)
Un facteur clé des systèmes portables, tels que les téléphones mobiles, est l'autonomie de la batterie qui dépend essentiellement de la source d'énergie, mais aussi de la façon dont sont gérés la tension et le courant qu'elle délivre, facteurs relatifs au régulateur et à son rendement. Les autres critères sont bien sûr la compacité et le coût, d'où la nécessité d'intégrer ces régulateurs de tension. Le premier chapitre présente brièvement trois types de régulateurs, ainsi que les contraintes imposées par les composants externes et la technologie de fabrication. Après avoir expliqué l'utilité de passer à une réalisation en technologie CMOS, le deuxième chapitre décrit le schéma final d'un régulateur linéaire (LDO, Low Drop-out), puis détaille sa stabilité et sa protection contre les courts-circuits. Pour cela, nous expliquons dans les deux cas la méthode habituellement utilisée, nous montrons ses limites dans le cadre de notre application, puis nous développons la solution adoptée qui consiste en une compensation Miller s'adaptant au courant de sortie pour sa stabilité et en un asservissement du courant de sortie plus performant pour limiter le courant de court-circuit. Des mesures sur silicium ont permis de valider les simulations effectuées lors de cette conception. Les alimentations à découpage sont une alternative à ces régulateurs linéaires, et procurent la possibilité d'élever la tension de batterie, mais nécessitent des éléments inductifs difficilement intégrables. Une étude de comportement statique permet de déterminer les pertes et le rendement de la structure choisie pour répondre à notre cahier des charges. L'analyse de sa stabilité par sa fonction de transfert complète ce chapitre. Les systèmes à pompe de charges sont abordés de façon succincte. Egalement basés sur le principe du découpage, ils sont un compromis entre les deux précédents principes et permettent, moyennant des pertes supplémentaires, d'éviter l'utilisation des composants inductifs.
5

Détection des courts-circuits inter-spires dans les Générateurs Synchrones à Aimants Permanents : Méthodes basées modèles et filtre de Kalman étendu - Application à un canal de génération électrique en aéronautique

Aubert, Brice 31 March 2014 (has links) (PDF)
La mise en place d'un nouveau canal d'alimentation électrique incorporant un générateur à aimants permanents PMG (Permanent Magnet Generator) en remplacement de l'actuel canal de génération hydraulique est l'un des sujets de recherche en cours dans le secteur aéronautique. Le choix de cette solution est motivé par de nombreux avantages : réduction de masse, meilleure disponibilité du réseau hydraulique et maintenance plus aisée. Cependant, l'utilisation d'un PMG en tant que générateur électrique au sein d'un avion implique de nouvelles problématiques, notamment en ce qui concerne la sûreté de fonctionnement lors de défaillances internes au PMG. En effet, tant que le rotor est en rotation, la présence d'une excitation permanente due aux aimants entretient la présence du défaut même si le stator n'est plus alimenté, ce qui complexifie la mise en sécurité du PMG. Il est ainsi nécessaire de connaître précisément l'état de santé du PMG afin d'assurer une bonne continuité de service en évitant d'ordonner la mise en sécurité du PMG sur des défaillances externes au générateur. C'est pourquoi les travaux de cette thèse portent sur la détection des courts-circuits inter-spires dans les PMG, ces défauts ayant été identifiés comme les plus critiques pour ce type de machine. Compte tenu du contexte aéronautique, il a été choisi de travailler sur les méthodes de détection basées sur l'estimation de paramètres via un modèle mathématique de la machine en utilisant le Filtre de Kalman Etendu (FKE). En effet, s'il est correctement paramétré, le FKE permet d'obtenir une bonne dynamique de détection et s'avère être très robuste aux variations du réseau électrique (vitesse, déséquilibre, ...), critère important pour garantir un canal de génération fiable. Deux types de modèle mathématique sont présentés pour la construction d'un indicateur de défaut utilisant les estimations fournies par le FKE. Le premier est basé sur une représentation saine du PMG où l'indicateur de défaut est construit à partir de l'estimation de certains paramètres de la machine (résistance, inductance, constante de fem ou pulsation électrique). Le second modèle utilise une formulation d'un PMG défaillant qui permet d'estimer le pourcentage de spires en court-circuit. Après avoir comparé et validé expérimentalement le comportement des différents indicateurs sur un banc de test à puissance réduite, la mise en place d'un indicateur de court-circuit inter-spires au sein d'un réseau électrique aéronautique et son interaction avec les protections existantes sur avion sont étudiées dans la dernière partie de ce mémoire.
6

Corrosion en eau supercitrique : Apport à la compréhension des mécanismes pour des alliages Fe-Ni-Cr de structure c.f.c / Mechanism study of c.f.c Fe-Ni-Cr alloy corrosion in supercritical water

Payet, Mickaël 28 June 2011 (has links)
L’eau supercritique peut être utilisée comme caloporteur à haute pression pour améliorer le rendement des centrales électriques. Pour un concept de réacteur nucléaire, la durée de vie des matériaux est un paramètre important en termes de sécurité. Par conséquent, les critères de sélection des matériaux pour un concept de réacteur à l’eau supercritique concernent les propriétés mécaniques à haute température pour une bonne tenue au fluage et à l’irradiation mais également une résistance à la corrosion généralisée et à la corrosion sous contrainte. Ce travail à pour objectif d’améliorer la compréhension des mécanismes de corrosion en eau supercritique à 600°C et 25 MPa pour des alliages c.f.c contenant du fer, du nickel et du chrome. Des essais de corrosion ont été réalisés sur des autoclaves échantillons d’alliages 316L et 690 en prenant en compte l’état de surface. Les couches d’oxydes formées ont été décrites en termes de morphologie, de composition et de structure, après caractérisations par microscopie électronique à balayage, par spectroscopie à décharge luminescente et par diffraction des rayons X. Si un comportement de type gazeux de l’eau supercritique est attendu dans les conditions d’essai, les résultats montrent une dissolution significative de certains éléments de l’alliage. Par conséquent, la corrosion en eau supercritique peut être considérée comme similaire à la corrosion aqueuse avec un effet de la température qui peut influencer la diffusion en phase solide par exemple. Pour l’alliage 690, la couche d’oxyde protectrice formée sur une surface polie est composée de chromine et surmontée d’un chromite ou d’un spinelle mixte de nickel et de fer. La double couche d’oxyde formée sur une surface de même finition pour l’alliage 316L semble moins protectrice. La couche externe de magnétite est poreuse et la couche interne riche en chrome est non homogène. Pour chaque alliage, l’étude des mécanismes de diffusion, grâce à des expériences utilisant des marqueurs ou des traceurs, révèle une croissance de la couche d’oxyde contrôlée par un processus anionique. Cependant, l’état de surface influence fortement les mécanismes de formation des couches d’oxyde. La comparaison des résultats sur l’acier suggère qu’il y a une concurrence entre l’oxydation du fer et celle du chrome. Une quantité suffisante de chrome est nécessaire pour former une fine couche d’oxyde protectrice. Les surfaces très déformées ou à microstructure à grains très fins conduisent à des fines couches d’oxyde de chrome, grâce à une forte densité de site de germination ou grâce aux courts-circuits de diffusion du chrome. L’état de surface est donc déterminant pour l’acier mais le même paramètre engendre des effets différents pour l’alliage à base de nickel. Les surfaces usinées deviennent sensibles à une oxydation interne du chrome, même si une fine couche d’oxyde continue et riche en chrome et manganèse se forme. Ce phénomène suggère une diffusion accélérée concurrentielle entre l’oxygène et le chrome. Pour conclure, ce travail propose un mécanisme de croissance de la couche d’oxyde dans chaque cas et discute des conditions favorables à la formation d’une couche d’oxyde protectrice riche en chrome dans l’optique d’une application au réacteur à eau supercritique. / Supercritical water can be use as a high pressure coolant in order to improve the thermodynamic efficiency of power plants. For nuclear concept, lifetime is an important safety parameter for materials. Thus materials selection criteria concern high temperature yield stress, creep resistance, resistance to irradiation embrittlement and also to both uniform corrosion and stress corrosion cracking.This study aims for supplying a new insight on uniform corrosion mechanism of Fe-Ni-Cr f.c.c. alloys in deaerated supercritical water at 600°C and 25MPa. Corrosion tests were performed on 316L and 690 alloys as sample autoclaves taking into account the effect of surface finishes. Morphologies, compositions and crystallographic structure of the oxides were determined using FEG scanning electron microscopy, glow discharge spectroscopy and X-ray diffraction. If supercritical water is expected to have a gas-like behaviour in the test conditions, the results show a significant dissolution of the alloy species. Thus the corrosion in supercritical water can be considered similar to corrosion in under-critical water assuming the higher temperature and its effect on the solid state diffusion. For alloy 690, the protective oxide layer formed on polished surface consists of a chromia film topped with an iron and nickel mixed chromite or spinel. The double oxide layer formed on 316L steel seems less protective with an outer porous layer of magnetite and an inhomogeneous Cr-rich inner layer. For each alloy, the study of the inner protective scale growth mechanisms by marker or tracer experiments reveals that diffusion in the oxide scale is governed by an anionic process. However, surface finishes impact deeply the growth mechanisms. Comparisons between the results for the steel suggest that there is a competition between the oxidation of iron and chromium in supercritical water. Sufficient available chromium is required in order to form a thin oxide layer. Highly deformed or ultra fine microstructure surfaces lead to thin chromium rich oxide layers thanks to either diffusion short circuiting or increasing Cr oxide nucleation site. The nature of the surface is a determining factor in the steel instance. The same parameter breeds different effects for the Ni-based alloy. Machined surfaces lead to internal oxidation on alloy 690 even if a thin Cr and Mn rich oxide scale is formed. Competitive diffusion of oxygen and Cr species through the diffusion short circuit paths of the alloy is suggested. This work proposes oxide growth mechanisms for each case. Finally the conditions leading to the formation of chromium-rich protective oxide films in supercritical water are discussed.
7

Evaluation of DC supply protection for efficient energy delivery in low voltage applications / Évaluation de l'alimentation en courant continu pour une distribution d'énergie efficace dans les appareils domestiques

Ma, Thi Thuong Huyen 05 April 2018 (has links)
Actuellement, il y a une baisse du prix des ressources énergétiques distribuées, en particulier l'énergie solaire photovoltaïque, conduisant à la croissance significative de leur capacité d'installation dans de nombreux pays. D'autre part, les politiques encourageant l'efficacité énergétique ont favorisé le développement de charges DC dans les zones domestiques, telles que l'éclairage LED, les ordinateurs,, les téléphones, les téléviseurs, les moteurs DC efficaces et les véhicules électriques. Grace à ce changement, le système de distribution de microgrid DC devient plus attractive que le système de distribution à courant alternatif traditionnel. Les avantages principaux du microgrid DC sont l'efficacité énergétique plus élevée, plus facile à intégrer avec les sources d'énergie distribuées et le système de stockage. Alors que de nombreuses recherches se concentrent sur les stratégies de contrôle et la gestion de l'énergie dans le microgrid DC, sa protection reçoit une attention insuffisante et un manque de réglementation et d'expériences. La protection dans les réseaux DC est plus difficile que dans le réseau AC en raison de l'arc continu, de la valeur plus élevée du courant de courtcircuit et du taux de défaut de montée. En outre, dans les réseaux distribués à courant continu sont composés de nombreux dispositifs de commutation électroniques et semi-conducteurs, qui ne supportent le courant de défaut que quelques dizaines de microsecondes. Les disjoncteurs mécaniques, qui ont un temps de réponse de quelques dizaines de millisecondes, ne semblent pas satisfaire aux exigences de sécurité du microréseau à courant continu. L'absence d'un dispositif de protection efficace constitue un obstacle au développement du microgrid DC dans le système distribué. Cette thèse propose un disjoncteur DC auto-alimenté à courant continu utilisant normalement JFET SiC, qui offre un excellent dispositif de protection pour les microgrids DC grâce à son temps de réponse rapide et ses faibles pertes à l'état passant. La conception du disjoncteur DC à semi-conducteurs vise à répondre à deux objectifs: temps de réponse rapide et fiabilité. Les spécifications conçues et les énergies critiques qui entraînent la destruction du disjoncteur sont identifiées sur la base des résultats mesurés d'un JFET populaire dans le commerce. Un pilote de protection très rapide et fiable basé sur une topologie à convertisseur flyback avant est utilisé pour générer une tension négative suffisante pour tourner et maintenir le JFET SiC. Le convertisseur sera activé chaque fois que le disjoncteur détecte des défauts de court-circuit en détectant la tension de drain-source de JFET et crée une tension négative s'applique à la porte de JFET. Pour éviter une défaillance de la porte par surtension au niveau de la grille du JFET, la tension de sortie du convertisseur de retour vers l'avant est régulée à l'aide de la mesure coté primaire. Les résultats expérimentaux sur le prototype du disjoncteur DC ont validé les principes de fonctionnement proposés et ont confirmé que le disjoncteur DC à semi-conducteurs proposé peut interrompre le défaut en 3 μs. D'un autre côté, un modèle du JFET normalement activé dans l'environnement Matlab/Simulink est construit pour étudier les comportements du SSCB pendant une durée de court-circuit. L'accord entre la simulation et les résultats expérimentaux confirment que ce modèle JFET peut être utilisé pour simuler le fonctionnement d'un disjoncteur DC et dans l'étude du fonctionnement du microgrid DC pendant le processus de défaut et de compensation / Currently, there is a drop in the price of distributed energy resources, especially solar PVs, which leads to a significant growth of the installed capacities in many countries. On the other hand, policies encouraging energy efficiency have promoted the development of DC loads in domestic areas, such as LEDs lighting, computers, telephones, televisions, efficient DC motors and electric vehicles. Corresponding to these changes in sources and loads, DC microgrid distribution system becomes more attractive than the traditional AC distribution system. The main advantages of the DC microgrid are higher energy efficiency, easier in integrating with distributed energy sources and storage systems. While many studies concentrate on the control strategies and energy management in the DC microgrid, the protection still receives inadequate attention and lack of regulations and experiences. Protection in DC grids is more complex than AC grids due to the continuous arc, higher short circuit current value and fault rate of rising. Furthermore, the DC distributed grids are composed of many electronic and semiconductor switching devices, which only sustain the fault currents of some tens of microseconds. Mechanical circuit breakers, which have a response time in tens of milliseconds, seem not to meet the safety requirement of DC microgrids. The lack of effective protection devices is a barrier to the development of DC microgrids in the distributed systems. This thesis proposes a self-power solid state DC circuit breaker using normally-on SiC JFET, which offers a great protection device for DC microgrids due to its fast response time and low on-state losses. The design of the solid state DC circuit breaker aims to meet two objectives: fast response time and high reliability. The designed specifications and critical energies that result in the destruction of the circuit breaker are identified on the basis of the experiments of a commercial normally-on JFET. In addition, a very fast and reliable protection driver based on a forward-flyback converter topology is employed to generate a sufficient negative voltage to turn and hold off the SiC JFET. The converter will be activated whenever short-circuit faults are detected by sensing the drain-source voltage, then creating a negative voltage applied to the gate of JFET. To avoid gate failure by overvoltage at the gate of JFET, the output voltage of the forward-flyback converter is regulated using Primary Side Sensing technique. Experimental results validated the working principle of the proposed solid state DC circuit breaker with fault clearing time less than 3 μs. Additionally, a model of the normally-on JFET in Matlab/Simulink environment is built for exploring the behaviors of the solid-state DC circuit breaker during short-circuit faults. The agreement between the simulation and experimental results confirms that this JFET model can be appropriately used for the investigation of solid state DC circuit breaker operations and DC microgrids in general during fault evens and clearing fault processes
8

Détection des courts-circuits inter-spires dans les Générateurs Synchrones à Aimants Permanents : Méthodes basées modèles et filtre de Kalman étendu / Inter-turn Short-circuit detection on Permanent Magnet Synchronous Machines : Model based method with Extended Kalman Filter

Aubert, Brice 31 March 2014 (has links)
La mise en place d’un nouveau canal d’alimentation électrique incorporant un générateur à aimants permanents PMG (Permanent Magnet Generator) en remplacement de l’actuel canal de génération hydraulique est l’un des sujets de recherche en cours dans le secteur aéronautique. Le choix de cette solution est motivé par de nombreux avantages : réduction de masse, meilleure disponibilité du réseau hydraulique et maintenance plus aisée. Cependant, l’utilisation d’un PMG en tant que générateur électrique au sein d’un avion implique de nouvelles problématiques, notamment en ce qui concerne la sûreté de fonctionnement lors de défaillances internes au PMG. En effet, tant que le rotor est en rotation, la présence d’une excitation permanente due aux aimants entretient la présence du défaut même si le stator n’est plus alimenté, ce qui complexifie la mise en sécurité du PMG. Il est ainsi nécessaire de connaître précisément l’état de santé du PMG afin d’assurer une bonne continuité de service en évitant d’ordonner la mise en sécurité du PMG sur des défaillances externes au générateur. C’est pourquoi les travaux de cette thèse portent sur la détection des courts-circuits inter-spires dans les PMG, ces défauts ayant été identifiés comme les plus critiques pour ce type de machine. Compte tenu du contexte aéronautique, il a été choisi de travailler sur les méthodes de détection basées sur l’estimation de paramètres via un modèle mathématique de la machine en utilisant le Filtre de Kalman Etendu (FKE). En effet, s’il est correctement paramétré, le FKE permet d’obtenir une bonne dynamique de détection et s’avère être très robuste aux variations du réseau électrique (vitesse, déséquilibre, …), critère important pour garantir un canal de génération fiable. Deux types de modèle mathématique sont présentés pour la construction d’un indicateur de défaut utilisant les estimations fournies par le FKE. Le premier est basé sur une représentation saine du PMG où l’indicateur de défaut est construit à partir de l’estimation de certains paramètres de la machine (résistance, inductance, constante de fem ou pulsation électrique). Le second modèle utilise une formulation d’un PMG défaillant qui permet d’estimer le pourcentage de spires en court-circuit. Après avoir comparé et validé expérimentalement le comportement des différents indicateurs sur un banc de test à puissance réduite, la mise en place d’un indicateur de court-circuit inter-spires au sein d’un réseau électrique aéronautique et son interaction avec les protections existantes sur avion sont étudiées dans la dernière partie de ce mémoire. / The establishment of an electrical power supply channel including a Permanent Magnet Generator (PMG) to replace an hydraulic power channel is one of the current topics of research in the aeronautic field. This choice is motivated by several benefits : weight reduction, improvement of the hydraulic network avaibility and easier maintenance. However, the use of PMG as an electrical generator in an aircraft implies new issues, particularly as regards safety considerations when an internal fault occurs in the PMG. Indeed, as long as the rotor in rotating, the presence of the persistent excitation due to the magnets maintains the internal fault even if the stator is de-energized. This makes the safety procedure of PMG more complex. Therefore, it is necessary to precisely know the behavior of the PMG (healthy or faulty) to ensure the avaibility of this power supply channel in order to avoid triggering PMG safety procedure when an external fault occurs. Thus, this work deals with the on-line detection of inter-turn short-circuits in PMG, these faults have been identified as the most critical for this kind of machine Given the aeronautic context, it has been decided to work on detection methods based on parameter estimation via a mathematical model of the machine using the Extended Kalman Filter (EKF). Indeed, with an appropriate setting, the EKF provides a fast dynamic detection and can be very robust to variations in the electrical network (speed, unbalanced, ...) which is an important characteristic to ensure a reliable generation channel. Two types of mathematical model are presented for fault indicator construction using the estimations provided by the EKF. The first one is based on an healthy representation of the PMG where the fault indicator is built from the estimation of PMG electrical parameters (resistance, inductance, electromotive force constant or electrical rotational velocity). The second model uses a faulty PMG formulation to estimate the ratio of short-circuited turns. After the comparison and the experimental validation of the fault indicators behavior on a test bench at reduced power, the establishment of a inter-turn short-circuit indicator within an aircraft electrical system and its interaction with existing protections are studied in the last part of this thesis.
9

Surveillance et diagnostic des machines synchrones à aimants permanents : détection des courts-circuits par suivi paramétrique / Monitoring and diagnosis of permanent magnets synchronous motor : Detection of short-circuits by parameter monitoring

Khov, Makara 17 December 2009 (has links)
Ce travail de thèse traite du problème de surveillance en ligne de défaillances électriques dans les entrainements électriques à base de machines synchrones à aimants permanents (MSAP) par une méthode de suivi paramétrique. Les défauts de court-circuit entre spires au stator sont souvent critiques et doivent être détectés au plus tôt avec un bon taux de confiance afin d’informer un système superviseur de la présence d’une défaillance pour limiter les risques encourues par l’environnement matériel et humain situé autour de la machine en défaut. La méthode que nous proposons de mettre en œuvre pour la détection des courts-circuits statoriques est basée des techniques d’identifications récursives. Nous proposons d’identifier en ligne les paramètres d’un modèle diphasé électrique de l’actionneur synchrone et d’analyser les variations des paramètres identifiées lors de l’apparition d’un défaut. Pour assurer les performances des méthodes d’identification, il est souvent nécessaire de disposer d’un signal d’excitation additionnel pour assurer les bonnes performances des algorithmes. Ces signaux peuvent cependant perturber le fonctionnement normal de la machine et entrainer des pertes additionnelles. Dans ce contexte, nous proposons une approche par identification faisant appel à un modèle diphasé spécifique appelé « le repère de Park à courants orientés ». Ce repère permet, tout en réduisant la complexité du problème d’identification, d’obtenir des propriétés d’auto-excitation intéressantes et donc d’éviter l’utilisation d’une excitation additionnelle. Des simulations sont menées à l’aide d’un modèle fin de la machine permettant de reproduire des situations de défaillances de manière virtuelle et d’éprouver l’efficacité des algorithmes dans ces situations dégradées. Cette machine, pouvant fonctionner en générateur ou en moteur, est intégrée dans un environnement complet, incluant le cas échéant une alimentation, une charge mécanique et éventuellement une commande, ce qui permet également de tester les algorithmes pour des fonctionnements en boucle ouverte et en boucle fermée. Les résultats présentés permettent de valider les techniques proposées et montrent qu’elles permettent d’extraire automatiquement, à partir des variations des paramètres identifiés, un indicateur de défaut. Des résultats expérimentaux sont également présentés en fonctionnement générateur sur une machine spécialement re-bobinée pour permettre la réalisation de défaut statoriques. Les algorithmes sont implantés sur une cible de calcul numérique afin de démontrer la faisabilité temps réelle de la détection / This work deals with the on-line monitoring of electrical faults in permanent magnet synchronous machine (PMSM) by parameter monitoring method. The inter-turns short-circuits faults in stator are often critical and have to be detected as early as possible with a high confidence rate to inform the supervisor system of the fault presence in order to limit the risk for the material and human environment. The proposed method is focus on the detection of short-circuits in stator and based on recursive identification technique. The on-line parameter identification uses an electrical diphase model of the PMSM and the analysis of the estimated parameter variations is performed to detect the presence of stator faults. In a general way, to ensure the performance of identification algorithms, it is necessary to have additional excitation signals. Consequently, those signals could disturb the normal operation of the drive. To overcome this problem, a specific diphase model in currents oriented Park reference frame is introduced for identification process. By reducing the complexity of identification problem, this reference frame provides an interesting auto-excitation property that leads to avoid the utilisation of additional excitation signals. The simulations are performed using an accurate model of PMSM that allows reproducing the failure situation and prove the efficiency of algorithms in degraded situations. This machine, operating as generator or motor, is integrated in a complete environment, included a power supply, mechanical load and control process. The detection scheme is then tested in open and closed loop operation. The results obtained from the simulation process underline the ability of the proposed technique to detect a stator fault occurrence and show that a fault indicator can be extracted automatically from the variation of estimated parameters. Experimental results are also achieved. A PMSM, with a specific winding including additional connexion points for stator short-circuit realisation is used. The algorithms are implemented in a numerical calculator in order to demonstrate the feasibility of the real-time faults detection for a generator operation mode