• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 621
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 649
  • 649
  • 423
  • 393
  • 350
  • 342
  • 196
  • 180
  • 101
  • 91
  • 73
  • 72
  • 68
  • 61
  • 59
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Separação dos enantiomeros do anestesico cetamina por cromatografia continua em leito movel simulado

Santos, Marco Antonio Garcia dos 20 March 2004 (has links)
Orientador: Cesar Costapinto Santana / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-03T21:25:30Z (GMT). No. of bitstreams: 1 Santos_MarcoAntonioGarciados_D.pdf: 4577065 bytes, checksum: 520c5362b49bf8229cc803bff6a92202 (MD5) Previous issue date: 2004 / Resumo: A grande maioria dos fármacos recentemente desenvolvidos provém de uma rota sintética que geralmente forma uma mistura racêmica, na qual dois isômeros quase idênticos denominados enantiômeros convivem na proporção de 50% cada um. Esses isômeros interagem de forma diferente com os receptores biológicos dos organismos, apresentando por isso diferentes atividades quando empregados como fármacos. Este fato, hoje em dia plenamente reconhecido, tem forçado a indústria farmacêutica a comercializar os enantiômeros puros em lugar da mistura racêmica, sempre que o composto em questão apresentar quiralidade. Isto tem intensificado a busca por novos e melhores métodos de separação enantiomérica. O leito móvel simulado (LMS) é um processo cromatográfico contínuo que tem sido aplicado com este fim, desde 1992. O processo consiste em simular o movimento do leito de adsorvente, de forma contracorrente ao movimento do líquido, através da troca periódica das posições das correntes de entrada e saída. Ao contrário dos sistemas tradicionais de cromatografia líquida de alta eficiência (CLAE), o processo LMS é operado de forma contínua, sem prejuízo da pureza das correntes de saída. Estas consistem no extrato, rica no componente mais fortemente adsorvido, e no refinado, rica no componente mais fracamente adsorvido, sendo o processo particularmente adequado a separações binárias, como é o caso da separação de racêmicos. O presente trabalho teve por objetivo a separação enantiomérica do anestésico cetamina num sistema LMS em escala semipreparativa, empregando como fase estacionária o acetato de celulose microcristalino e como fase móvel e sol vente o etanol anidro. As atividades iniciais envolveram o empacotamento das colunas, sua posterior caracterização com determinação das isotermas lineares de adsorção dos enantiômeros através de um sistema de análise de CLAE, e a calibração dos analisadores das correntes, que consistiam em um espectrofotômetro UV MS e um polarimetro. Em seguida, procedeu-se à realização de corridas experimentais sob 6 condições diferentes, nas quais a variável estudada consistiu na taxa de alimentação de racêmico em gldia, numa tentativa de estabelecer os limites de aplicação das isotermas lineares, válidas somente para sistemas com baixas concentraçõe. As correntes de saída foram analisadas através dos medidores em linha à unidade (UVNIS e polarímetro ligados em série) e através do sistema de CLAE, contendo uma coluna de análise empacotada com a mesma fase estacionária empregada no LMS. Os resultados obtidos mostraram que as condições com as três menores taxas de alimentação de racêmico apresentaram elevados valores de pureza para o refinado (> 99,5%) e valores satisfatórios para o extrato (> 95%), enquanto que nas outras três corridas com os maiores valores de taxa de alimentação a pureza do refinado mostrou-se insuficiente (entre 60 e 70%) e a do extrato continuou satisfatória (> 92%). Desta forma ficou estabelecido o limite máximo da taxa de alimentação abaixo do qual as isotermas lineares são aplicáveis, e foi evidenciada a necessidade de determinação das isotermas não-lineares, válidas para sistemas concentrados. Esse estudo poderá ser efetuado em trabalhos futuros que poderão aumentar a produtividade da separação da cetamina no sistema LMS até níveis aceitáveis industrialmente / abstract: The great majority of the pharmaceuticals recently developed arise from a synthetic route which generally forms a racemic mixture, in which two almost identical isomers named enantiomers are together in the proportion of 50% each. These isomers interact by different manners with the biological receptors of living organisms and therefore present different activities when employed as pharmaceuticals. Due to this fact, fully recognized today, the pharmaceutical industry has been forced to market pure enantiomers instead of the racemic mixture whenever a chiral compound is involved. This has risen the search for new and improved methods of enantioseparation. The simulated moving bed (SMB) is a chromatographic process that has been employed with this aim, since 1992. The process consists in simulating the countercurrent movement of the adsorbent bed by switching the positions of the inlet and outlet streams. Unlike the traditional HPLC (High Performance Liquid Chromatography) systems, the 5MB process operates continuously, without lowering the purity of the outlet streams. It produces two outlet streams, one rich in the more adsorbable component (extract stream), and the other rich in the less adsorbable one (raffinate stream), and is particularly adequate for binary separations, such as the case of racemates. The present work investigated the enantioseparation of the anesthetic ketamin in a 5MB system at semipreparative-scale, employing microcrystaline cellulose triacetate as stationary phase and ethanol as mobile phase. The initial activities of the thesis work were the packing of the columns, their characterization through determination of linear adsorption isotherms for the enantiomers employing a HPLC system of analysis, and the calibration ofthe stream analyzers, which consisted ofa spectrophotometric WNIS meter and a polarimeter. Experimental runs under 6 different conditions were carried out, in which the variable studied was the racemate throughput in grams/day, in an attempt to establish the limits of application of the linear isotherms, which are valid only for systems with low solute concentrations. The output streams were analyzed by the on-line meters (W NIS and polarimeter connected in series) and by the HPLC system, containing an analytical column packed with the same stationary phase employed in the 5MB. The results obtained showed that the three conditions with the lowest racemate throughputs presented very good purity values for the raffinate (> 99.5%) and satisfactory values for the extract stream (> 95%), whereas in the other three runs with the highest throughputs, the raffinate purity was insufficient (between 60 and 70%) and the extract purity remained satisfactory (> 92%). These results have established the upper limit of throughput below which the linear isotherms are applicable, and the need of determining the non-linear isotherms, valid for concentrate systems, became evident. This study can be carried out in future works which can improve the productivity of ketamin enantioseparation in the 5MB system up to acceptable levels in industry / Doutorado / Doutor em Engenharia Química
42

Estudo de bioequivalencia de duas formulações de diclofenaco em voluntarios sadios

Silva, Lara Cristina 31 May 1999 (has links)
Orientador: Gilberto de Nucci / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-25T10:39:51Z (GMT). No. of bitstreams: 1 Silva_LaraCristina_M.pdf: 2182987 bytes, checksum: 2bdcb2030921ff01f4e2f4a70fd6f42a (MD5) Previous issue date: 1999 / Resumo: O resumo poderá ser visualizado no texto completo da tese digital / Abstract: The abstract is available with the full electronic digital document / Mestrado / Farmacologia / Mestre em Farmacologia
43

Aprimoramento da metodologia para determinação de carotenoides em alimentos

Kimura, Mieko 25 July 2018 (has links)
Orientador: Delia Rodriguez-Amaya / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-25T23:15:57Z (GMT). No. of bitstreams: 1 Kimura_Mieko_D.pdf: 17703920 bytes, checksum: 25a02fd1a3ce56562c993c7459615650 (MD5) Previous issue date: 2000 / Resumo: Devido à grande importância que os carotenóides representam em várias áreas do conhecimento, é consenso mundial que uma maior disponibilidade de dados confiáveis sobre a sua composição em alimentos é necessária. No entanto, a determinação de carotenóides não é uma tarefa simples e apesar dos avanços na instrumentação analítica, discrepâncias nos resultados quantitativos podem ser encontrados na literatura internacional. Assim, o aprimoramento da metodologia para determinação de carotenóides continua prioritário e é o grande objetivo de muitos pesquisadores no mundo inteiro. Atualmente, a cromatografia líquida de alta eficiência (CLAE) é a técnica preferida para a determinação de carotenóides devido ao menor tempo envolvido na análise, reutilização da coluna, menor exposição à luz e oxigênio e melhor capacidade de separação, principalmente dos componentes minoritários. Entretanto, esta técnica está sujeita a varias fontes de erros como: incompatibilidade entre solvente de injeção e fase móvel, identificação equivocada, indisponibilidade, impureza e instabilidade dos padrões de carotenóides, quantificação de picos altamente sobrepostos, baixa recuperação da coluna cromatográfica, erros na preparação das soluções padrões e procedimento de calibração e erros de cálculo. Ilustrações dos possíveis erros na quantificação de carotenóides por CLAE são apresentados e discutidos no capítulo 1. Para se obter uma identificação e quantificação correta é imprescindível que uma boa resolução dos componentes durante a separação cromatográfica seja alcançada. A cromatografia clássica foi considerada por muito tempo, mais arte que ciência, uma vez que o seu êxito dependia largamente da habilidade e experiência do analista. A introdução da CLAE e os avanços na fabricação de colunas tornaram a cromatografia moderna mais ciência, mas que ainda depende da habilidade do analista para escolher adequadamente a combinação coluna e fase móvel. Os vários parâmetros que devem ser considerados para se chegar às combinações apropriadas são discutidos no capítulo 2. As melhores condições dependem do objetivo da análise, isto é, determinação da composição total ou apenas dos carotenóides principais, e da composição de cada tipo de amostra. Ilustrações de várias combinações para quatro tipos de amostras são apresentadas ¿Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital. / Abstract: Not informed. / Doutorado / Doutor em Ciência de Alimentos
44

Analise por cromatografia liquida de alta eficiencia de compostos peralogenados do tipo CxBRyCLz (x = 1 ou 2; Y + Z = 4 ou 6)

Leone, Priscila de Almeida 15 July 2018 (has links)
Orientador : Carol Hollingworth Collins / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-15T01:59:53Z (GMT). No. of bitstreams: 1 Leone_PrisciladeAlmeida_M.pdf: 5214338 bytes, checksum: 707f797ee6fcbee27c197d9beda5f685 (MD5) Previous issue date: 1988 / Mestrado
45

Tratamento termico na imobilização de fases estacionarias para cromatografia liquida de alta eficiencia / Thermal treatment for the immobilization of stationary phases for high performance liquid chromatography

Vigna, Camila Rosa Moraes 07 March 2004 (has links)
Orientador: Carol Hollingworth Collins / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-04T04:16:32Z (GMT). No. of bitstreams: 1 Vigna_CamilaRosaMoraes_M.pdf: 3265030 bytes, checksum: cfba60975ab2867d42279c2358e8e067 (MD5) Previous issue date: 2004 / Mestrado / Quimica Analitica / Mestre em Química
46

Desenvolvimento de metodologia analítica para determinação de folatos em alimentos

Paiva, Emmanuela Prado de 31 January 2012 (has links)
Made available in DSpace on 2014-06-12T23:04:26Z (GMT). No. of bitstreams: 2 arquivo9587_1.pdf: 3117616 bytes, checksum: 149954eac9b67ed47b28898dbdb58267 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2012 / Vitamina B9 é constituída por um grupo de compostos com características químicas similares denominadas folatos. Sua principal função é atuar como cofatores ou coenzimas na transferência de unidades de carbono para síntese de ácidos nucleicos. Sua ausência na dieta humana pode desencadear distúrbios distintos, a exemplo dos distúrbios de formação do tubo neural. Tendo em vista a gravidade das doenças associadas, tem aumentado à necessidade do controle dos valores declarados nos rótulos de alimentos e tabelas de composição e, consequentemente, o desenvolvimento de metodologias analíticas seletivas e apropriadas a matrizes de diferente composição química. A cromatografia líquida de alta eficiência tem se destacado como método analítico mais utilizado para este fim, pois apresenta resultados eficientes para diferentes formas de folatos. Entretanto, a maioria dos protocolos de estudo de extração de folatos exige o uso de enzimas, soluções extratoras em diferente pH, controle de temperatura e tempo de exposição na etapa de extração. Essas condições têm gerado resultados contraditórios, o que motivou este estudo a desenvolver um protocolo analítico simplificado para as etapas de identificação, extração e quantificação. Com soluções padrão contendo seis formas de folatos foi possível desenvolver um método cromatográfico em eluíção isocrática com tempo de eluíção dos padrões de 15 minutos em detector de arranjo de diodo. Foram testadas três colunas com diferentes dimensões recheadas com octadesilsilano em mais de dez combinações de fases móveis alcançando-se Rs, α e k compatíveis com um protocolo capaz de ser executado em matrizes alimentares e explicado através da teoria de ácido-base Lewis. Este método foi testado em espinafre e utilizado para o estudo do protocolo de extração, através de estudo piloto isolando fatores, a saber: uso de enzimas, concentração molar da solução extratora, agentes desproteinizante, antioxidantes, temperatura e tempo de exposição e o espinafre usado como modelo de estudo fracionado em liquor e fibra. De posse dos elementos principais foi desenhado um planejamento fatorial 24 objetivando verificar a melhor condição de extração, e posteriormente o método desenvolvido foi testado em seis matrizes alimentícias de origem vegetal. Para a etapa de extração, as condições de tempo e temperatura exercem influência sobre as condições de extração, e as condições mais brandas de exposição podem garantir uma maior extratibilidade. Ademais o fracionamento da matriz potencializou a extração do 5-metil-tetraidrofolato na fração liquor
47

Estudo da Fotoestabilidade de Vitaminas em Formulações para Nutrição Parenteral Pediátrica

AZEVEDO FILHO, Clayton Anderson de 17 December 2012 (has links)
Submitted by Heitor Rapela Medeiros (heitor.rapela@ufpe.br) on 2015-03-03T18:44:22Z No. of bitstreams: 2 AzevedoFilhoCA_Tese_2012.pdf: 4376283 bytes, checksum: 86e9722ae8d9ae768d8b18c7ae14170a (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-03T18:44:22Z (GMT). No. of bitstreams: 2 AzevedoFilhoCA_Tese_2012.pdf: 4376283 bytes, checksum: 86e9722ae8d9ae768d8b18c7ae14170a (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-12-17 / FACEPE, CAPES, PROPESQ/UFPE e CNPq / Formulações de nutrição parenteral (NP) são soluções ou emulsões, estéreis e apirogênicas, compostas por carboidratos, aminoácidos, lipídeos, eletrólitos e elementos traços. Essas preparações são geralmente suplementadas com vitaminas antes do começo da terapia, sendo administrado de forma contínua por um período de 12 a 18h/dia. As vitaminas são usadas para atender as necessidades diárias e suprir deficiências, principalmente em neonatos, muito embora sejam instáveis e tenham na degradação química a mais comum causa da perda destes componentes nas bolsas de NP. Fatores tais como a luz, temperatura e duração do tempo de estocagem podem levar à degradação das vitaminas. Vários autores relatam a fotossensibilidade das vitaminas, em especial as vitaminas A, E, C, B2 e B6, que são nutrientes imprescindíveis no crescimento e na regulação das diferentes funções fisiológicas. Atualmente, pouco se relata sobre a fotoestabilidade das vitaminas principalmente em condições controladas de exposição à radiação UV. O Núcleo de Pesquisas em Nutrição Parenteral (NP)2 da Universidade Federal de Pernambuco (Brasil) desenvolveu uma câmara de fotoestabilidade a fim de estudar o efeito da radiação UV (UVA e UVB) sobre os componentes das formulações de nutrição parenteral. Esta câmara está qualificada e atende aos requisitos do Quality Guideline (Q1B) opção 2 de acordo com o International Conference on Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH). Um novo procedimento de quantificação de vitaminas lipossolúveis e hidrossolúveis extraídas de formulações de NP foi desenvolvido por cromatografia líquida de alta eficiência (CLAE). As vitaminas hidrossolúveis extraídas foram separadas em uma coluna SB C18 (150 mm x 4.6 mm, 3.5 μm) em uma única corrida em eluição gradiente de fase móvel consistindo de tampão fosfato 0.05 mol.L-1 pH 4.75 (solvente A) e metanol (solvente B). As vitaminas lipossolúveis foram separadas na mesma coluna em uma única corrida aplicando eluição isocrática com metanol como fase móvel. Repetibilidade e precisão intermediária do método foi determinado a partir das extrações (em triplicata) em dois dias diferentes no mesmo nível de concentração. As variabilidades das concentrações em dois dias aleatórios foram de CV (%) = 0.32 a 11.54% para vitaminas lipossolúveis e CV (%) = 0.73 a 10.60% para vitaminas hidrossolúveis. O presente método é adequado para a análise quantitativa de 9 vitaminas em formulações de NP: (vitamina A (retinol e palmitato de retinila), vitamina D3 (colecalciferol), vitamina E (DL-α-tocoferol e acetato de DL-α-tocoferol), vitamina B2 (riboflavina), vitamina B6 (piridoxina), vitamina C (ácido ascórbico) e vitamina B3 (niacinamida). Os experimentos de fotodegradação foram realizados em formulações contidas em tubos de vidro e em bolsas plásticas. Intensidade de luz UV de uma Unidade de Terapia Intensiva Neonatal de um hospital público em Recife (Brasil) foram monitorados diariamente e a dose de radiação UV foi determinada e simulada em uma câmara de fotoestabilidade. Um período de 10h de dose UV na Unidade Neonatal determinada foi equivalente a 15,67 min de exposição UV na câmara de fotoestabilidade. A fotodegradação das vitaminas nas formulações de NP neonatal (contidas em bolsas de EVAC e em frascos de vidro) foi monitorada por um período de 0–60 min. A determinação simultânea de 7 vitaminas presentes nessas misturas de NP foi realizada e o perfil fotodegradativo de cada uma delas foi discutido.
48

Composição de carotenoides de produtos de maracuja, manga e açai

Silva, Sandra Regina da 31 July 2018 (has links)
Orientador: Adriana Zerlotti Mercadante / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-31T19:36:36Z (GMT). No. of bitstreams: 1 Silva_SandraReginada_D.pdf: 29343911 bytes, checksum: 865db1d94cca7ffdd5f0bf50c9178d50 (MD5) Previous issue date: 2002 / Resumo: Neste trabalho determinou-se a composição de carotenóides e o valor de vitamina A de maracujá-amarelo in natura, de diferentes produtos comerciais de maracujá (polpa congelada, sucos pasteurizado e concentrado congelado açucarado, bebidas à base de suco e soja e à base de suco e iogurte) e de polpa congelada de açaí. Os carotenóides pró-vitamínicos A de produtos comerciais de manga (polpa congelada, sucos pronto para beber, pasteurizado e concentrado congelado) foram investigados. Todas as 99 amostras foram adquiridas em Campinas, São Paulo. Em todas as amostras os carotenóides foram extraídos com acetona e após transferência para éter de petróleo/éter etílico, o extrato foi saponificado. Os carotenóides foram separados em cromatógrafo líquido de alta eficiência equipado com detector de arranjo de diodos e coluna C18 e como fases móveis acetonitri/almetanol/acetato de etila nas proporções de 75:15:1O para maracujá e açaí e de metanollacetato de etila, 90:10 para os produtos de manga. Em todas as amostras de maracujá e em seus produtos foram encontrados os seguintes carotenóides: beta-criptoxantina, prolicopeno, 'dzeta'-caroteno, cis-'dzeta'-caroteno, all-trans-'dzeta'-caroteno, e 13-cis-beta-caroteno, além de outros carotenóides minoritários. ... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital. / Abstract: In this work the carotenoid composition and vitamin A value of fresh yellow passion fruit, different commercial products of passion fruit (frozen pulp, pasteurized, ready-to-drink and sweetened concentrated frozen juices, and soft drinks made with soy and yogurt), and of frozen pulp of açaí were determined. The provitamin A carotenoids from many mango commercial products (frozen pulp, ready-to-drink, pasteurized and sweetened concentrated frozen juices) were investigated. All 99 samples were acquired in Campinas, São Paulo. The carotenoids trom ali samples were extracted with acetone, transterred to petroleum ether/diethyl ether and saponified. The carotenoids were separated by high performance liquid chromatography equipped with diode array detector and 'C IND. 18' column with the following mobile phases acetonitrile/methanollethyl acetate (75: 15:10) for passion fruit and açaí, and methanollethyl acetate (90:10) for mango products. In all samples of fresh passion fruit and its different products the following carotenoids were found: beta-cryptoxathin, prolycopene, cis 'dzeta'-carotene, 'dzeta'-carotene, all-trans-beta-carotene, 13-cis-beta-carotene, and other minor carotenoids. ... Note: The complete abstract is available with the full electronic digital thesis or dissertations. / Doutorado / Doutor em Ciência de Alimentos
49

Estudo fitoquimico de Lonchocarpus latifolius (Willd) DC leguminosae - isolamento, determinação estrutural, atividade biologica e analise sazonal

Nogueira, Marisa Alves 23 July 2018 (has links)
Orientador: Eva Gonçalves Magalhães / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-23T22:13:34Z (GMT). No. of bitstreams: 1 Nogueira_MarisaAlves_D.pdf: 6389081 bytes, checksum: d3bb25f95973a5732c9744c32926d0ad (MD5) Previous issue date: 1998 / Doutorado
50

Desenvolvimento de fases estacionarias C-8 sorvidos e imobilizadas para CLAE a partir de silica zirconizada

Melo, Lucio Flavio Costa 24 July 2018 (has links)
Orientador: Isabel Cristina Sales Fontes Jardim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-24T01:41:50Z (GMT). No. of bitstreams: 1 Melo_LucioFlavioCosta_M.pdf: 2630353 bytes, checksum: 4c2f798e472fbf4b2cd2f1232b1b89b0 (MD5) Previous issue date: 1998 / Mestrado

Page generated in 0.0611 seconds