• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 3
  • 3
  • Tagged with
  • 39
  • 17
  • 14
  • 14
  • 13
  • 12
  • 10
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Gestion des risques de contamination et leur détection en animalerie axénique

Lebeuf, Maria 26 May 2021 (has links)
L'usage d'animaux axéniques comme modèles a augmenté exponentiellement dans les dernières années en recherche expérimentale. Afin de conserver leur statut axénique, les animaux doivent être contenus dans des isolateurs traditionnels ou des isolateurs au niveau de la cage, incluant la cage scellée à pression positive de Tecniplast : l'Isocage. Cependant, le moyen le plus efficace de confirmer leur statut axénique des animaux reste incertain, particulier pour les isolateurs au niveau de la cage, comportant un plus grand risque de contamination que l'isolateur traditionnel en raison de leur contact plus fréquent avec l'environnement extérieur. Ce projet de maîtrise a pour buts de gérer le risque de contamination associé à l'Isocage en optimisant la désinfection par immersion et en déterminant l'efficacité des mesures de précautions axéniques, puis finalement de déterminer l'efficacité des mesures de détection à démontrer la présence de contaminants en cages axéniques Les travaux d'optimisation de la désinfection par immersion a permis de déterminer la charge microbienne résiduelle retrouvée à la surface des Isocages entre deux changements de cage, d'évaluer l'efficacité sporicide de deux désinfectants, et finalement de déterminer le temps optimal de désinfection pour l'immersion des cages axéniques lors d'un changement de cage selon la concentration du désinfectant utilisé. L'efficacité de mesures de précaution axéniques a été confirmée en comparant les flores microbiennes retrouvées à la surface de cages contenues dans des locaux axéniques et non axéniques. L'efficacité des mesures de détection à démontrer la présence de contaminants en Isocage a été déterminée en développant, validant et optimisant trois différentes méthodes, puis en testant in situ leur efficacité à détecter des contaminants artificiellement introduits dans des cages axéniques. Cet ouvrage constitue un apport important au domaine puisqu'il est l'un des premiers à aborder la gestion des risques et l'efficacité des méthodes de détection lors d'utilisation de l'Isocage et du bassin d'immersion annexé à la station de biosécurité avec des animaux axéniques. / The use of axenic animals as models have increased exponentially in recent years in experimental research. In order to maintain their axenic status, animals must be contained in traditional isolators or isolators at the cage level, which includes Tecniplast's sealed positive pressure Isocage. However, the most effective way to confirm animal axenic status remains uncertain, especially for cage-level isolators, which carry a greater risk of contamination than the traditional isolator due to their most frenquent contact with outer environment. This Master's project aims were to manage the risk of contamination associated with Isocage by optimizing disinfection by immersion and determining the effectiveness of axenic precautionary measures; then finally to determine the effectiveness of the detection measures to demonstrate the presence of microbial contaminants in axenic Isocages. The optimization of disinfection by immersion made it possible to determine the residual microbial load found on the surface of Isocages between two cage changes, to evaluate the sporicidal efficiency of two disinfectants, and finally to determine the optimal disinfection time for the immersion of the axenic cages during a change of cage depending on the concentration of disinfectants used. The effectiveness of axenic precautionary measures has been confirmed by comparing the microbial flora found on the surface of cages contained in axenic and non-axenic rooms. The effectiveness of detection measures to demonstrate the presence of contaminants in Isocage has been determined by developing, validating and optimizing three different methods, then by testing in situ their effectiveness to detect contaminants artificially introduced into axenic cages. This work constitutes an important contribution to the field since it is one of the first to discuss risk management and the effectiveness of detection methods when using Isocage and the immersion basin attached to the biosecurity station with axenic animals.
2

Caractérisation de la toxicocinétique des trihalométhanes et des acides chloroacétiques administrés sous forme de mélanges chez le rat

St-Pierre, Annie January 2004 (has links)
Thèse numérisée par la Direction des bibliothèques de l'Université de Montréal.
3

Sous-produits de la désinfection dans l'eau potable des petits réseaux municipaux: variabilité spatio-temporelle, modélisation et stratégies de suivi

Guilherme, Stéphanie 20 April 2018 (has links)
Les trihalométhanes (THM) et les acides haloacétiques (AHA) constituent les seules familles réglementées de sous-produits de la désinfection (SPD). Les SPD sont des composés issus de la réaction de la matière organique naturelle présente dans l’eau et du désinfectant lors du traitement de l’eau potable. La plupart de ces composés ne sont pas réglementés, même si plusieurs études ont montré que certains SPD peuvent présenter un risque toxicologique plus important que les THM et les AHA. De nos jours, très peu d’informations sont disponibles sur l’occurrence des SPD non-réglementés dans l’eau potable, en particulier dans les petits réseaux municipaux. Paradoxalement, les petits réseaux approvisionnés en eau de surface ont souvent des difficultés à mettre en place des traitements adéquats pour enlever les précurseurs de SPD dans l’eau soumise à la désinfection. L’eau potable des petits réseaux est ainsi plus vulnérable aux SPD et leur suivi y est d’autant plus important. Cette thèse s’est donc consacrée à améliorer les connaissances sur l’occurrence des SPD (et en particulier, les SPD non-réglementés) dans les petits réseaux de distribution d’eau potable, en étudiant notamment leur évolution spatiale et temporelle. Pour ce faire, deux campagnes d’échantillonnage ont été réalisées sur deux ans (entre 2010 et 2012) dans 25 petits réseaux du Québec et de Terre-Neuve-et-Labrador. Les THM, les AHA et trois autres familles de SPD non-réglementés, à savoir les haloacétonitriles, les halonitrométhanes et les haloacétones, ont été étudiés. Les résultats obtenus ont permis de mieux comprendre leur patron de variabilité spatio-temporelle, de modéliser leur présence et de développer un outil d’aide à la décision pour la mise en place d’une stratégie de suivi des SPD réglementés et non-réglementés. / Trihalomethanes (THMs) and haloacetic acids (HAAs) constitute the only regulated disinfection by-products (DBPs) in various countries. DBPs are compounds formed during drinking water treatment, from the reaction between natural organic matter and the disinfectant. Most DBPs are not regulated, even if they may have more pronounced toxicological effects than regulated ones. There is currently very little information about the occurrence of non-regulated DBPs, particularly in small water systems (SWS). Paradoxically, in many cases, SWS supplied by surface waters lack adequate treatment processes to remove DBP precursors in water subjected to the disinfection process. Their tap water may be more vulnerable to the presence of DBPs. This thesis is dedicated to improving the knowledge of the occurrence of DBPs (especially non-regulated DBPs) in SWS by studying their spatial and temporal variability. To do that, two sampling programs were carried out in 25 SWS during two years (between 2010 and 2012) in Canada. Small systems in the provinces of Newfoundland & Labrador and Quebec were considered. The following DBPs were measured during the study: THMs, HAAs, haloacetonitriles, haloketones and halonitromethanes. The obtained results contribute to a better understanding of the DBP spatio-temporal variation patterns, to establishing models to evaluate their levels and to developing decision-making schemes for simultaneously monitoring various families of DBPs, including non-regulated DBPs.
4

Synthèse et évaluation des activités antimicrobiennes de nouveaux dérivés 3,20-bis (pollyaminostéroïdiens). Applications en thérapeutique humaine / Synthesis of new 3,20-bis (polyaminosteroid) derivatives and evaluation of their antimicrobial activities. Application in human therapeutics

Djouhri Bouktab, Lamia 15 December 2011 (has links)
Les dérivés aminostéroïdiens analogues de la squalamine ont été largement étudiés pour leur large spectre d’activité sur les bactéries et les champignons multirésistants. Nous avons réalisé la synthèse de nouveaux dérivés aminostéroïdiens et présentant de nombreuses charges positives liées à la présence de groupements azotés, les 3,20-bis(polyaminostéroïdes) analogues de la squalamine. Une étude de la relation structure-activité a démontré l’importance des charges positives induites par la présence d’atomes d’azote dans les chaines carbonées portées par le motif cholestane. Nous avons mis en évidence les mécanismes d’action mis en oeuvre vis-à-vis des bactéries Gram positive et Gram négative. L’étude des activités antifongiques démontre que la squalamine et le dérivé aminostéroïdien DAS-1 possèdent de bonnes activités sur diverses souches de levures impliquées dans de nombreuses fongémies, avec des CMIs variant de 1 à 16 μg/mL. Nous avons étudié les applications potentielles de ces dérivés et démontré que ces dérivés en formulation de pommades à 1% de squalamine et de dérivé 3.20-bis(polyaminostéroïdien) étaient capables de réduire efficacement la colonisation cutanée à S. aureus sur un modèle animal. Il a été démontré que ces dérivés bis(polyaminostéroïdiens) sont également très actifs vis-à-vis de bactérie et de champignons multirésistants isolés des patients mucoviscidosiques. Nous avons testé leur activité en tant qu’agent désinfectant de matériel médical et plus particulièrement les nébuliseurs. La formation de cachets hydrosolubles à base de squalamine, nous a permis de développer un modèle de désinfection simple, rapide et peu onéreux des nébuliseurs contaminés. / Aminosterol derivatives analogues of squalamine possess a broad spectrum activity against multidrug resistant bacteria and fungi. We synthesized a new series of 3,20-bis(polyaminosteroïd) analogues involving a titanium reductive amination possessing numerous positives charges due to the presence of nitrogen groups. The study of relation structure-activity demonstrates that the nature of the amino group attached to the sterol plays a crucial role on antimicrobial activity of these compounds. We had also determined the mechanism of action of bis(polyaminosteroïd) on Gram negative and Gram positive bacteria. The study of antifungal activity of squalamine and aminosterol derivative ASD-1 show a good activity against various yeast responsible of fungal infections, minimal inhibitrice concentration ranging from 1 to 16 μg/mL. We studied a potential application of these compounds in human therapeutic. We evaluated squalamine and related parent-derived ointments (1%) as potential new compounds for S. aureus decolonization in a new mouse model. Using this model we found that squalamine ointment (1%) was able to reduce efficiently S. aureus colonization. Squalamine and bis(polyaminosteroïd) derivatives were actives against multidrug resistant bacteria and fungi isolated from cystic fibrosis patients. We investigated the potential use of squalamine compound in vitro in a nebulizer disinfection model. A formulation of squalamine disinfecting soluble tablets at 2.5 % (W/W) was developed and successfully applied for rapid nebulizer disinfection.
5

Intéraction de bactériophages avec des surfaces colonisées par des biofilms d'eau potable et évaluation de protocoles de nettoyage / Interaction of bacteriophages with surfaces colonised with drinking water biofilm and evaluation of cleaning protocols efficiency

Pelleïeux, Sandra 18 June 2013 (has links)
Bien que les microorganismes pathogènes soient rarement détectés au sein de réseaux de distribution d'eau potable, ils peuvent constituer un danger pour la santé humaine en cas de contamination accidentelle. Le devenir des virus entériques au sein d'un système de distribution d'eau est largement méconnu, alors que de telles informations sont nécessaires pour améliorer les procédures de prise en charge en cas d'incidents. Dans ce contexte, trois bactériophages ARN F-spécifiques, MS2, GA et Q[bêta], ont été utilisés comme modèles des virus entériques pathogènes, dans des conditions expérimentales mimant un système de distribution d'eau. Ce travail visait d'une part à comparer l'accumulation des phages sur des surfaces en polyéthylène haute densité (PEHD) colonisées ou non par des biofilms d'eau potable et d'autre part à évaluer, sur les bactériophages adhérés, l'efficacité de protocoles de nettoyage basés sur une chloration ainsi qu'une augmentation des contraintes hydrodynamiques. En résumé, les différentes vitesses d'eau étudiées n'ont pas conduit à des différences significatives dans l'accumulation des bactéries et des phages sur les surfaces, mais ont toutefois abouti à des concentrations surfaciques en phages significativement supérieures à celles observées en conditions hydrostatiques. Quelles que soient les conditions expérimentales (vitesses d'eau à la surface, présence ou absence d'un biofilm), le bactériophage MS2 présente systématiquement les plus faibles concentrations sur les surfaces. La séquence d'adhésion des trois bactériophages sur biofilms est en accord avec leur séquence d'hydrophobicité. Le protocole de chloration (4 à 5 mg Cl2.L-1) évalué dans cette étude peut être ponctuellement appliqué en cas de contamination de l'eau. Après 60 minutes de chloration, l'abattement est de 0,7 log10 pour les bactéries et il est compris entre 2 et 3 log10 pour les phages adsorbés sur les surfaces, alors qu'aucun phage infectieux n'est plus détecté dans l'eau dès 5 minutes de chloration. Ces résultats soulignent l'effet protecteur du biofilm, même jeune. Enfin, la chloration apparaît être plus efficace que l'augmentation des contraintes hydrodynamiques pour éliminer les bactériophages adhérés aux surfaces / Although pathogens remain widely uncommon in water distribution networks, they may constitute a real threat for human health when accidentally introduced in the system. There is a lack of knowledge about virus behaviour into water distribution systems whereas such information is critical for a better viral risk management. In this context, three F-specific RNA bacteriophages -MS2, GA and Qbeta- were used as models, in experimental conditions mimicking water distribution systems. The purpose of the present work was at first to compare the viral accumulation of bacteriophages on high-density polyethylene (HDPE) colonised or not with drinking water biofilms. The second objective was to evaluate, on phages adsorbed in the biofilm, the efficiency of a cleaning protocol, based on chlorination and increase in the hydrodynamic strengths. To sum up, the water velocities tested in this work had little influence on both the bacterial and virus accumulation on surfaces, but applying a water flow led to an increase in the number of adsorbed phages in comparison with hydrostatic conditions. Whatever the conditions (water velocity, colonisation or not with a biofilm) MS2 phage was found to be the less adherent one. On HDPE colonised with a two-month old biofilm, the adhesion sequence was consistent with the sequence of hydrophobicity of the phages. The chlorination protocol tested in our study (4 to 5 mg CL2/L) can be applied punctually in distribution networks. After 60 minutes of chlorination the log-reduction was about 0.7 log10 for bacteria and between 2 and 3 log10 for bacteriophages, while no more infectious phages were detected in water after 5 minutes. Those results highlight that even two-month-old biofilms provide to viruses a protection against disinfection protocol. At last, the chlorination appears to be more efficient to inactivate viruses adsorbed on surfaces than an increase in the water flow velocity
6

Etude du traitement de désinfection des eaux de refroidissement par le couplage H2O2/UV : Application à une tour aéroréfrigérante

Putois, Tamara 10 October 2012 (has links) (PDF)
Les légionelles sont un enjeu de santé publique majeur car ces bactéries sont responsables des cas de légionellose, parfois mortels. Les tours aéroréfrigérantes (TAR) peuvent être incriminées car pouvant potentiellement émettre des aérosols contaminés. Un traitement de désinfection de ces eaux est donc nécessaire. Cependant les techniques actuelles conduisent très souvent à des injections importantes de réactifs induisant des rejets écotoxiques dans l'environnement qu'il est nécessaire de limiter. L'application du traitement d'oxydation avancée H2O2/UV - considéré comme innovant pour ce domaine et dont l'impact environnemental est limité (décomposition du peroxyde d'hydrogène en eau et oxygène, peu de production de composés toxiques) - a prouvé son efficacité de désinfection à la fois au sein d'un pilote de laboratoire sur une eau reconstituée, chargée en microorganismes et matière organique, mais aussi lors du traitement de l'eau d'une TAR du secteur tertiaire. Les ultraviolets ont été appliqués de manière continue (10 à 22 J.cm-2 sur le pilote ; 2 à 7 J.cm-2 sur la TAR) avec le maintien d'un résiduel constant en peroxyde d'hydrogène (10 à 50 mg.L-1 sur le pilote ; 3 à 10 mg.L-1 sur la TAR). Sur le pilote de laboratoire, le traitement H2O2/UV a montré une efficacité supérieure à l'application des UV ou du peroxyde d'hydrogène seul. Des abattements plus importants sur les paramètres microbiologiques de l'eau et des biofilms (ATP, bactéries cultivables et totales) et une modification profonde de la matière organique (minéralisation) ont pu être observés. Il a ainsi été conservé les avantages de chaque technique (désinfection reconnue des UV et action bactéricide de H2O2), tout en limitant leurs inconvénients (absence de rémanence des UV, fortes concentrations nécessaires en H2O2) grâce à la génération de radicaux hydroxyles pouvant agir sur les microorganismes et la matière organique. L'étude sur une TAR a confirmé ces résultats et a montré de bonnes performances de désinfection en comparaison avec celles obtenues pour le dioxyde de chlore. Cependant, lors les phases d'optimisation des essais, une adaptation des bactéries au peroxyde d'hydrogène a été observée indiquant la nécessité d'un contrôle régulier de cet oxydant afin de maintenir un résiduel conséquent et d'éviter la mise en place d'une dérive du système. De plus, il a été montré que le traitement n'a eu qu'une faible action sur les produits de conditionnement de l'eau (antitartre, anticorrosion). Une rapide évaluation économique a permis de placer le couplage H2O2/UV dans le même ordre de grandeur que les traitements habituels.
7

Étude des cibles bactériennes du procédé photocatalytique : devenir des bioaérosols dans les filtres photocatalytiques / Study of the potential bacerial targets of photocatalysis : analysis of the behaviour of microorganisms within photocatalytic filters

Pigeot-Rémy, Stéphanie 07 February 2012 (has links)
La qualité de l’air que nous respirons à l’intérieur des espaces clos est devenue une préoccupation environnementale majeure. Il est aujourd’hui avéré que la présence de microorganismes dans l’air intérieur peut avoir des conséquences néfastes sur la santé humaine. Les systèmes de ventilation, lorsqu’ils sont mal entretenus, peuvent être eux-mêmes la source de bioaérosols suite à la contamination de leurs filtres. Afin de pallier ce problème, des filtres photocatalytiques ont été développés et testés dans des centrales de traitement d’air (CTA). Ce projet de thèse s’intéresse donc au devenir des microorganismes aérosolisés dans des filtres photocatalytiques. La première étape a consisté à étudier les mécanismes de dégradation par photochimie et photocatalyse d’une bactérie modèle, Escherichia coli (E. coli), en suspension dans l’eau sous irradiation UV-A ou UV-C. Ces deux traitements sont plus efficaces sous UV-C et engendrent des dommages oxydatifs au niveau de la membrane externe et des acides nucléiques bactériens. Le dosage de sous-produits chimiques permet de conclure que la photocatalyse UV-C est plus efficace pour dégrader irréversiblement les bactéries. La seconde étape a été consacrée à l’étude de l’inactivation de spores d’Aspergillus niger et de bactéries E. coli dans les filtres Ahlstrom. Nos résultats confirment l’intérêt d’utiliser des filtres photocatalytiques dans les CTA en comparaison avec les filtres non photocatalytiques. L’utilisation de filtres à haute efficacité, afin d’optimiser le temps de contact entre les microorganismes et le dépôt de dioxyde de titane, permet d’augmenter l’efficacité de dégradation du procédé photocatalytique / Indoor Air Quality (IAQ) has become of particular concern from an environmental and health and safety point of view. It is now proven that the presence of microorganisms in indoor air can have hazardous consequences on human health. HVAC systems, when poorly maintained, can themselves become source of bioaerosols when their filters are contaminated. To tackle this issue, photocatalytic filters have been developed and tested within HVAC systems. The aim of this PhD thesis is to look at the behaviour of microorganisms aerosolized through photocatalytic filters. The first step consisted of analysing the photochemistry and photocatalysis degradation mechanisms of a model bacterium, Escherichia coli (E. coli), in suspension in water under UV-A or UV-C radiation. These two treatments were proven to be more efficient under UV-C radiation and led to oxidative damages to outer membrane and nucleic acids. The measurement of chemical by-products allowed us to conclude that UV-C photocatalysis is more effective in damaging bacteria in an irreversible manner. The second step focused on the analysis of the inactivation of Aspergillus niger spores and E. coli bacteria within Ahlstrom filters. Our results confirm the benefits of using photocatalytic filters in HVAC systems instead of non-photocatalytic filters. The use of high efficiency filters to optimise the contact between the microorganisms and the titanium dioxide deposit, allows an increase in the damaging efficiency of the photocatalytic process
8

Etude de facteurs biotiques et abiotiques qui contrôlent l'implantation des biofilms de Pseudomonas aeruginosa dans les réseaux de distribution d'eau thermale / Study of biotic and abiotic factors that control the implementation of Pseudomonas aeruginosa biofilms in thermal water distribution networks

Pessereau, Coline 04 November 2015 (has links)
Les eaux minérales naturelles se distinguent de l’eau potable par leur contenu en sels minéraux et en éléments traces. Leur utilisation à des fins thérapeutiques s’effectue sous contrôle médical dans des établissements thermaux. La gestion des réseaux de distribution ainsi que la qualité microbiologique de l’eau font l’objet de réglementations. Malgré la mise en place de procédures spécifiques, les établissements thermaux sont régulièrement confrontés à des contaminations microbiologiques majoritairement dues à P. aeruginosa. Ce pathogène opportuniste possède d’importantes capacités d’adaptation, de résistance et de persistance dans l’environnement, notamment sous forme de biofilms. L’objectif de ces travaux de thèse est d’apporter des éléments de compréhension sur le comportement de P. aeruginosa dans les réseaux de distribution d’eau minérale naturelle et de valider l’efficacité de produits de traitement. L’influence de la composition minérale de 3 eaux sur les capacités à former du biofilm de 9 souches de P. aeruginosa d’origines diverses a pu être démontrée. Il apparait que les quantités de biofilms produites au bout de 24 h sont moins importantes pour la minéralisation forte. La modulation de la production de facteurs de virulence en fonction de la qualité de l’eau est corrélée à l’action spécifique de certains ions et à la biodisponibilité du fer. En conditions de minéralisation forte il a été montré que les matériaux organiques favorisent la formation de biofilm de P. aeruginosa tandis que les matériaux métalliques ont tendance à la défavoriser. L’efficacité d’une séquence de traitement de postes de soins a pu être validée sur un modèle de biofilm âgé de 24 h et sur tous les matériaux. / Natural mineral waters are distinguished from drinking water bytheir content in minerals and trace elements. Their use for therapeuticpurposes under medical control is performed in spas. Management ofdistribution networks and the microbiological quality of water are subjectto regulations. Despite the establishment of specific procedures, spas areregularly confronted with microbiological contamination mainly due to P.aeruginosa. This opportunistic pathogen has substantial adaptive capacity,resistance and persistence in the environment, under biofilm.The aim of this thesis work is to bring understanding on the P.aeruginosa behaviour in the natural mineral water distribution networksand validate the effectiveness of treatment products.The influence of the mineral composition of 3 waters on biofilmformation capacity of 9 P. aeruginosa strains of various origins could bedemonstrated. It appears that the amount of biofilm produced after 24 hare less important for the strong mineralization. Modulation of theproduction of virulence factors depending on the water quality iscorrelated to the specific action of certain ions and iron bioavailability. Inhigh mineralization conditions it has been shown that organic materialspromote biofilm formation of P. aeruginosa while metallic materials tendto disadvantage it. The efficiency of a treatment sequence of a patient pointof use has been validated on the 24 h biofilm model and on all materials.
9

Étude de la performance d'un système de désinfection de la solution nutritive par ozonisation sur les aspects microbiologiques et agronomiques d'une culture de tomate de serre

Laplante, Marc André 12 April 2018 (has links)
La performance d'un système de désinfection de la solution nutritive par ozonisation sur les aspects microbiologiques et agronomiques a été déterminée pour une culture de tomate de serre. Des doses d'ozone de 3,5, 5,3 et 14,1 ppm ont été appliquées à la solution nutritive et les résultats furent insatisfaisants. Ces mauvais résultats pourraient s'expliquer par un contact insuffisant entre les molécules d'ozone et les microorganismes dans le système spécifique installé dans le cadre de ce projet. L'ajout de peroxyde et/ou de chlore a permis d'améliorer la désinfection de façon importante. Le chlore a procuré les meilleurs résultats avec une élimination de plus de 92 % des bactéries tandis que le peroxyde a amélioré la désinfection d'environ 30 à 40 %. La meilleure désinfection a été obtenue par l'injection d'ozone (9 ppm) et de chlore (8 ppm). Le traitement combinant l'ozone à 9 ppm et le chlore à 8 ppm a été appliqué pour une culture complète de tomate. La désinfection a été quasi parfaite (plus de 99 % pour les bactéries et 100 % pour les champignons) avec ces doses. Nous avons, en outre, mesuré l'effet des traitements de désinfection et du recyclage sur la composition minérale des solutions nutritives et la productivité des cultures. La croissance et le développement, la qualité et le rendement d'une culture de tomate n'ont pas été affectés par la désinfection à l'ozone et au chlore ainsi que par le recyclage des solutions nutritives.
10

Développement d'une démarche pour améliorer la désinfection secondaire et la qualité de l'eau potable au Nunavik : projet pilote à Kangiqsualujjuaq

Garcia Sanchez, Cristian Ruben 14 September 2022 (has links)
La population des villages du Nunavik, au nord du Québec, a généralement accès à l'eau potable municipale à partir de réservoirs domestiques. L'eau brute, qui vient généralement d'une source de surface, est amenée à l'usine de traitement municipale pour être traitée avec des rayons ultraviolets et du chlore, puis distribuée à la communauté par des camions citernes. Une campagne d'échantillonnage de l'eau réalisée en 2019 dans trois villages du Nunavik a mis en évidence que la désinfection par chloration n'est pas suffisante pour assurer une protection adéquate pendant la distribution et le stockage domestique de l'eau. L'objectif de ce mémoire de maîtrise a été de développer une stratégie pour améliorer la désinfection secondaire de l'eau par chloration au Nunavik, en utilisant comme étude de cas le village de Kangiqsualujjuaq. Pour ce faire, un portrait de la qualité de l'eau entre la source et les robinets a été dressé, avec une emphase sur le chlore résiduel et les sous-produits de désinfection. Avec ce portrait, une démarche a été mise au point pour identifier les quantités adéquates de chlore permettant d'obtenir des concentrations de désinfectant résiduel répondant aux standards internationaux, tout en limitant la génération de sous-produits de désinfection. Ces doses adéquates ont été obtenues à l'aide simulations de chloration en laboratoire réalisées avec des eaux de la communauté collectées en 2020 et en 2021. Avec les informations obtenues sur le terrain et dans les expériences de laboratoire, une base de données d'aide à la décision a été développée pour permettre aux responsables de la communauté de faire des choix éclairés quant à l'application du chlore pour la désinfection secondaire de l'eau. / The inhabitants of the villages of Nunavik, in northern Quebec, have generally access to municipal water stored in their domestic tanks. Municipal drinking water is commonly produced in a treatment plant supplied by a surface source, where ultraviolet light and chlorination are applied. Treated water is then distributed to the community by tanker trucks. A water sampling campaign conducted in 2019 in three Nunavik villages highlighted that secondary disinfection by chlorination is not sufficient to ensure adequate protection during water distribution and storage. The objective of this project was to develop a strategy to improve the secondary disinfection by chlorination, using the village of Kangiqsualujjuaq as case study. A profile of the water quality from source to tap was drawn up, with an emphasis on residual chlorine and disinfection by-products. Based on this portrait, a strategy was implemented to identify adequate chlorine doses to achieve disinfectant residual concentrations that meet international standards, while limiting the generation of disinfection by-products. These adequate doses were obtained using laboratory simulations of chlorination performed with community waters collected in 2020 and 2021. Based on the collected information, a decision support database was developed to allow community managers to make informed choices about the application of chlorine for secondary disinfection of water.

Page generated in 0.1162 seconds