• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 133
  • 39
  • 24
  • 2
  • Tagged with
  • 196
  • 79
  • 71
  • 50
  • 33
  • 32
  • 26
  • 26
  • 25
  • 23
  • 22
  • 22
  • 20
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Caractérisation de matrices de détecteurs sensibles à l'infrarouge pour intégration dans un spectromètre par tranformation de Fourier imageur

Kretschmer, Erik 12 April 2018 (has links)
La conception d'instruments de mesure optique complexes comme des spectromètres par transformation de Fonder nécessite l'intégration de plusieurs sous-systèmes jouant tous un rôle critique dans les performances de l'ensemble. Ce mémoire fait d'abord un survol de l'intégration des systèmes lors de la conception d'un spectromètre par transformation de Fourier imageur avec une emphase particulière sur l'intégration du détecteur dans l'instrument. Une présentation des méthodes habituelles de caractérisation des performances des détecteurs sensibles à la lumière infrarouge; est ensuite effectuée puis une nouvelle méthode est proposée. Cette nouvelle approche de caractérisation de responsivité de détecteurs est dérivée; des techniques utilisées habituellement. Une étude de la théorie sous-jacente à cette méthode de caractérisation de responsivité est faite et les hypothèses requises sont présentées. Par la suite, une étude des performances de bruit des détecteurs est effectuée; et une méthode d'analyse expérimentale qui vise principalement à évaluer le bruit de grenaille de photodétecteur est analysée.
72

Technologies pour la reconnaissance et l'acquisition d'images des débris spatiaux avec HiCIBaS-II (T.R.A.S.H.)

Watanabe-Brouillette, Koichi 30 May 2024 (has links)
Les objets spatiaux en basse orbite dont les satellites et les débris spatiaux représentent une menace croissante; leur vitesse relative fait que même les plus petits représentent un potentiel danger pour les infrastructures spatiales. Alors que les instruments optiques et radars permettent une bonne couverture des débris de grande taille (> 1 m), la population de débris spatiaux proche du centimètre est mal représentée dans les catalogues. Le suivi de ces objets implique l'utilisation d'un imageur fixe sur des observatoires ou des satellites à la recherche d'objets en mouvement, mais cette solution est coûteuse et le temps d'accessibilité est limité selon le nombre de projets. Une alternative est d'utiliser les ballons stratosphériques pour l'observation du ciel avec un détecteur capable d'effectuer des acquisitions rapides, empêchant ainsi le signal faible de l'objet d'être noyé dans le signal du bruit de fond. Ce projet de recherche se concentre sur l'observation de cette population de débris, en utilisant une caméra *Electron Multiplying Charge Coupled Device*, Hnü512 de Nüvü Caméras, avec sa capacité de comptage de photons et une fréquence d'acquisition rapide, dans le domaine du visible sur un ballon stratosphérique à 35-40 km d'altitude. Le lancement du ballon stratosphérique a été effectué le 22 août 2023 à la base de lancement de l'Agence Spatiale Canadienne, à Timmins, Ontario. Ce document présente les différentes phases de la conception d'une charge utile et une analyse d'une séquence d'empilement d'un objet en mouvement sur 113 acquisitions avec un champ de vue de 2,347°, un temps d'exposition de 4,5 ms et un gain EM de 2500. De plus, ce projet est en collaboration avec le projet HiCIBaS-II, un télescope pour l'observation directe d'exoplanète par imagerie à haut contraste embarqué sur un ballon. Ce travail contribue à l'effort global sur la connaissance de la situation spatiale en évaluant l'impact de l'inclusion de l'imagerie optique embarquée dans les systèmes de détection sur ballon. / Low-orbit space objects represent a growing threat ; their relative speed means that even the smallest objects are a potential danger to space infrastructures. While optical and radar instruments provide good coverage of large debris objects (> 1 m), the near-centimeter space debris population is poorly represented in catalogs. Tracking these objects involves searching for moving objects using a fixed imager on observatories or satellites, but this solution is costly and time is limited by the number of astronomical projects. An alternative is to use stratospheric balloons for sky observation, with a detector capable of making short exposures, thus preventing the object's weak signal from being drowned out by the background signal. This research project focuses on observing this debris population, using an Electron Multiplying Charge Coupled Device camera, Hnü512 from Nüvü Cameras, with its photon-counting capability and fast frame rate, in the visible range on a stratospheric balloon at 35-40 km altitude. The stratospheric balloon was launched on August 22, 2023 from the Canadian Space Agency's launch pad in Timmins, Ontario. This document presents the various phases involved in designing a payload and an analysis of a stacking sequence of a moving object over 113 acquisitions with a field of view of 2.347°, an exposure time of 4.5 ms and an EM gain of 2500. In addition, this project is in collaboration with the HiCIBaS-II project, a balloon-borne telescope for direct observation of exoplanets using high-contrast imaging. This work contributes to the global effort on space situational awareness by assessing the impact of including onboard optical imaging in balloon-based detection systems.
73

Étude des propriétés optiques et électriques dans les verres P₂O₅-Na₂O-Nb₂O₅ en vue de leur intégration dans des systèmes de détection de gaz à haute température

Landry, Annie-Kim 24 April 2018 (has links)
L’incorporation d’oxyde de niobium, un métal de transition à valence multiple, dans des verres de phosphates permettrait leur intégration dans des systèmes de détection de gaz à haute température puisqu’ils présentent des propriétés optiques et électriques modulables en fonction de la température et de l’atmosphère. Dans le cadre de cette maîtrise, les verres (60-x)P₂O₅-xNa₂O-40Nb₂O₅ où x = 23, 27, 30 et 33 %mol ont été étudiés afin d’évaluer l’influence de la composition et de la température sur l’état d’oxydation du niobium. Sous forme d’oxyde, le niobium se retrouve généralement dans un état d’oxydation Nb(V) de forme Nb₂O₅, un composé incolore. Lorsque l’oxyde de niobium est réduit partiellement, il se retrouve sous forme NbO₂ d’état d’oxydation Nb(IV) qui présente une coloration bleu-noir. Les verres ont été traités thermiquement sous air et sous atmosphère partielle d’hydrogène (90Ar/10H₂) entre 450 et 630 °C. Les propriétés optiques ont été mesurées par spectrophotométrie UV-visible et permettent d’observer une large bande d’absorption dans le domaine du visible jusqu’au proche infrarouge suite aux traitements thermiques réducteurs. Une analyse de Résonance Paramagnétique Électronique (RPE) permet de révéler la présence d’espèces Nb⁴⁺ responsables de la coloration bleu-noir des verres. Les analyses Raman démontrent que le niobium se retrouve en sites octaédriques NbO₆ pour toutes les compositions et qu’une diminution de la concentration en ions Na⁺ permet d’augmenter le nombre d’oxygènes pontants et favorise ainsi la réduction du niobium. De plus, les verres présentent une conductivité électrique mixte ionique-électronique entre 10⁻¹⁰ et 10⁻³ S·cm⁻¹ sur une gamme de températures entre 25 et 575 °C. La conductivité ionique est due à la mobilité des ions Na⁺ dans le réseau vitreux et est plus importante lorsque la concentration de ce porteur de charge augmente. La conductivité électronique est due à la présence d’espèces Nb⁵⁺ et Nb⁴⁺. La coloration bleu foncé des verres ainsi que la conductivité électronique peuvent être expliquées par des phénomènes de transfert de charge soit respectivement le transfert de charge d’intervalence et le saut de petit polaron. Finalement, des analyses DRX, DSC, de densité, d’indice de réfraction et d’analyse thermogravimétrique (ATG) ont aussi été effectuées sur ces verres. / The incorporation of niobium oxide, a mixed valency transition metal, in phosphate glasses would allow their integration in high temperature gas detection systems because they have optical and electrical properties that can be modulated according to the temperature and the atmosphere. In this study, the glasses (60-x)P₂O₅-xNa₂O-40Nb₂O₅ where x = 23, 27, 30 and 33 mol% were studied to evaluate the influence of the composition and the temperature on the oxidation state of niobium. In the oxide form, niobium is generally found in an oxidation state Nb(V) of composition Nb₂O₅, a colorless compound. When the niobium oxide is reduced, it is found in NbO2 composition with Nb(IV) oxidation state, which exhibits a dark-blue coloration. The glasses were heat-treated in air and hydrogenated atmosphere (90Ar/10H₂) between 450 and 630 °C. The transmittance properties were measured by UV-visible spectrophotometry resulting in a broad absorption band in the visible range up to the near-infrared following reductive thermal treatments. Electron paramagnetic resonance analysis revealed the presence of Nb⁴⁺ species responsible for the dark-blue coloration of glasses. Raman analyzes show that niobium is found in octahedral sites NbO₆ for all the compositions and a decrease in Na⁺ ions makes it possible to increase the number of bridging oxygens and thus favors the reduction of niobium. In addition, the glasses have a mixed electrical ion-electron conductivity between 10⁻¹⁰ and 10⁻³ S·cm⁻¹ over a temperature range between 25 and 575 °C. The ionic conductivity is due to the mobility of the Na⁺ ions in the vitreous lattice and is more important when the concentration of this charge carrier increases. Electronic conductivity is due to the presence of Nb⁵⁺ and Nb⁴⁺ species. The dark-blue coloration of the glasses and the electronic conductivity can be explained by interatomic charge transfer phenomenons, respectively know as intervalence charge transfer and the small polaron hopping. Moreover, XRD, DSC, density, refractive index and TGA analyzes were also performed on theses glasses.
74

Development of luminescent bolometers and light detectors for neutrinoless double beta decay search / Développement de bolomètres luminescents et détecteurs de lumière pour la recherche de la double désintégration bêta sans émission de neutrinos

Tenconi, Margherita 28 September 2015 (has links)
L'étude de la double désintégration bêta sans neutrinos joue un rôle important dans plusieurs questions en physique des particules et cosmologie. Ce processus nucléaire hypothétique viole la conservation du nombre leptonique par deux unités et jusqu'à présent il est le seule moyen pratique pour dévoiler la nature du neutrino : sa détection implique forcement que neutrino et antineutrino sont la même particule. En outre, le taux de décroissance est sensible à la masse efficace de Majorana du neutrino, du coup à l'échelle absolue des valeurs propres de la masse et leur hiérarchie. La marque expérimentale de la DDB0ν est un pic monochromatique dans le spectre énergétique de la somme des deux électrons émis. Le but des expériences de prochaine génération est une sensibilité sur la masse efficace du neutrino de l'ordre de dizaines de meV, c'est-à-dire demi-vies de l'ordre de 10²⁷-10²⁸ années : en pratique, il s'agit de construire des sources de quelques centaines de kg d'isotope candidat, au moins, et les sonder par des détecteurs très efficients, tout en gardant le bruit de fond dans la région énergétique d'intérêt au niveau d'un coup/tonne/an. Les bolomètres luminescents sont une technique prometteuse vu leur excellentes résolutions énergétiques, haute efficacité de détection, ample choix pour les matériaux et extensibilité modulaire à grande échelle; de plus, grâce à la détection simultanée de chaleur et lumière produites par l'interaction des particules, il est possible de discriminer les contaminations α, dangereuse source de bruit aux énergies d'intérêt pour plusieurs noyaux candidats à la DDB0ν. Cette thèse a été effectuée dans le contexte de l'expérience LUMINEU : une expérience pilote qui a pour but la construction d'une expérience de prochaine génération basée sur les bolomètres scintillants en molybdate de zinc, pour l'étude de l'isotope candidat ¹⁰⁰Mo. En vue de la construction d'une expérience à grande échelle, il est nécessaire d'effectuer des caractérisations systématiques pour s'assurer des performances et de la reproductibilité des détecteurs et leurs composantes. La disponibilité d'installations expérimentales en surface, facilement accessibles, est souhaitable pour des tests routiniers : j'ai mené la plupart des expériences au CSNSM, où j'ai aussi travaillé à l'installation d'un nouvel cryostat à dilution basé sur la technologie du Pulse-Tube. Une partie de ma thèse a concerné l'étude de détecteurs bolométriques de lumière aux absorbeurs en germanium et thermomètres NTD (thermistors Neutron Transmutation Doped) : une structure standard pour LUMINEU a été établie et on a mesuré les performances des bolomètres telles que sensibilité, résolution énergétique, bruit de base et reproductibilité. Les résultats sont satisfaisants en vue d'un emploi dans une expérience avec bolomètres scintillants, bien que la configuration soit très sensible à la microphonie. En outre, j'ai testé avec succès des détecteurs bolométriques de lumière exploitants l'effet Neganov-Luke, qui augmente le rapport signal-bruit au niveau compatible avec la détection de la lumière Cherenkov pour la discrimination des événements. Une autre partie a vu la caractérisation des bolomètres scintillants en molybdate de zinc avec masse allant jusqu'à environ 300 g : couplés aux capteurs de lumière susmentionnés et lus par thermistors NTD, ils ont été refroidis en surface au CSNSM et en endroit souterrain à Modane, dans l'installation de l'expérience EDELWEISS pour la Matière Noire. Grâce à la détection simultanée de lumière et chaleur, les interactions des particules β/γ sont séparées des contaminations α. Les résultats démontrent que la caractérisation de bolomètres massifs, presque la taille cible des détecteurs finaux, est possible même en surface, en dépit du rayonnement cosmique. En outre, ces tests ont permis d'optimiser la compatibilité de l'installation de Modane avec les exigences des bolomètres scintillants pour la recherche de la DDB0ν. / Neutrinoless Double Beta Decay (0νDBD) is regarded as an important key in the decryption of some hot astroparticle and cosmological enigmas: it violates lepton number by two units and it is currently the only known practical way to shed light on the neutrino nature, being possible only in case of a Majorana neutrino, identical to its antiparticle. Moreover, the 0νDBD rate is sensitive to the effective neutrino mass, so it would be useful to define the absolute neutrino mass scale and hierarchy. The experimental footprint of 0νDBD is a monochromatic peak in the sum energy spectrum of the two emitted electrons. Next-generation experiments aim at reaching a sensitivity on the effective neutrino mass of the order of ten meV, corresponding to half lives in the range 10²⁷-10²⁸ years: this means to be able to gather, at least, a few hundred kilograms of 0νDBD candidate isotope source and to efficiently scrutinize it with very sensitive detectors. Meanwhile, background levels in the energy region of interest of the 0νDBD signal should be lowered to less than one count/ton/y. Cryogenic luminescent bolometers are a promising technique for 0νDBD search, as they feature excellent energy resolutions, high detection efficiency, flexibility in the material choice and easy scalability to large modular experiments; furthermore, the simultaneous read-out of heat and light signals produced by particle interactions provides an active discrimination method against the dangerous α contaminations, populating the 0νDBD energy region of several interesting candidate isotopes. The work presented in this dissertation was carried out in the context of the LUMINEU project: a pilot experiment focused on zinc molybdate scintillating bolometers, to define the strategies for the construction of a next-generation experiment based on the 0νDBD candidate ¹⁰⁰Mo. In view of the construction of a large 0νDBD experiment, involving hundreds of modules, systematic cryogenic measurements have to be performed to ensure good performance and reproducibility of the detectors and their components. Aboveground facilities are preferred for routinary tests because of their easier accessibility: most of the tests were carried out at CSNSM, where I also worked on the setup of a new cryogenic apparatus, based on the Pulse-Tube technology. One part of my thesis work saw the study of bolometric light detectors based on germanium absorbers and Neutron Transmutation Doped (NTD) thermometers: a proper design was developed in view of LUMINEU and the devices were characterized in terms of sensitivity, energy resolution, baseline noise and reproducibility. The results are compatible with a 0νDBD search final experiment, though this detector configuration is very sensitive to vibrational noise. In addition, the feasibility of bolometric light detectors based on NTD thermometers and Neganov-Luke amplification was investigated, demonstrating that this technique can actually boost the signal-to-noise gain to a level compatible with event discrimination based on Cherenkov light detection. Another part of my work dealt with the test of scintillating zinc molybdate bolometers of mass up to ~300 g, coupled to the aforementioned light detectors and operated both in the aboveground facilities at CSNSM and underground at Modane, in the cryostat of the EDELWEISS Dark Matter search experiment. Good event discrimination capability was achieved: thanks to double read-out of heat and light, it is possible to identify α particles, the threatening background for 0νDBD interests, against β/γ interactions. The results proved the possibility to pre-characterize aboveground detectors of mass close to the one of a final experiment module, despite the high cosmic rays rates. Besides, the measurements opened the way to the mutual compatibility of the underground setup, conceived for another kind of experiment, and LUMINEU 0νDBD search detectors.
75

Développement de détecteur gazeux à micropistes pour le trajectographe de l'expérience CMS et mesures de rapports d'embranchement de désintégrations hadroniques du méson B dans l'expérience BaBar

Zghiche, A. 22 January 2007 (has links) (PDF)
Les détecteurs gazeux à micropistes (MSGC) ont fait l'objet d'un vaste programme de recherche et développement dans le but de les qualifier pour équiper le trajectographe de l'expérience Compact Muon Solenoid (CMS) installée sur l'un des 4 points d'interaction du collisionneur proton proton de 14 TeV: le Large Hadron Collider (LHC) en construction au CERN. Les points étudiés les plus critiques pour que les MSGC et leurs variantes telles que les grilles de multiplication d'électrons (GEM) fonctionnent dans l'environnement difficile du LHC sont: la tenue aux flux de particules très ionisantes, le vieillissement dû aux radiations ainsi que la rapidité du signal pour un déclenchement à 40 MHz. Les paramètres importants pour l'optimisation du gain de ces détecteurs sont le mélange de gaz, la résistivité des substrats qui constituent le support des détecteurs et le métal des pistes. L'étude de ces paramètres a permis de définir le détecteur gazeux qui assure une stabilité de fonctionnement avec un gain constant pendant dix ans de collisions LHC. Il se compose de deux étages de multiplication d'électrons dans le gaz (amplification), associant un détecteur MSGC à un détecteur GEM. <br /> L'expérience BaBar, installée sur l'anneau PEP II à SLAC, a été conçue pour étudier la violation de CP dans le système des mésons B. Les premières collisions e+ e- ont été enregistrées en mai 1999. En août 2006, la luminosité intégrée enregistrée par l'expérience s'élevait à plus de 390 fb-1 dont 350 fb-1 à la résonance Y(4S) correspondant à plus de 385 millions de désintégrations e+ e- -> Y(4S)->BB. Dès les conférences de l'été 2001, la collaboration BaBar avait pu présenter la première observation significative de la violation de CP dans le secteur des B. Avec l'accumulation des données, la précision statistique de cette mesure s'est améliorée de plus qu'un facteur 4 et la précision systématique de près d'un facteur 3. Le grand nombre de désintégrations BB permet aussi de construire un échantillon de données où un premier méson B est totalement reconstruit. Les paramètres du second B sont alors calculés à partir de ceux des faisceaux et du premier B. Grâce à cet échantillon, la détermination du nombre de charme moyen (le nombre de quarks c produits dans les désintégrations des mésons B) avec les mesures inclusives des désintégrations des mésons B- et B0 en mésons D et Ds et baryons charmés Λc a pu être effectuée séparément pour les mésons B chargés et neutres en s'affranchissant d'un grand nombre d'hypothèses ainsi que des erreurs systématiques qui en découlent. Avec le même échantillon de données, la mesure des rapports d'embranchement des modes B- ->D0(* , **)pi - et B 0->D+(* , **)pi- a été effectuée avec une méthode originale dans BaBar, celle de la masse manquante. Dans le système du second B, les rapports d'embranchement ont été mesurés en calculant la masse manquante au pi -, qui est le module du quadrivecteur impulsion manquant (les quadrivecteurs impulsion du Y(4S), du premier méson B et du pi- étant déterminés). Ceci a permis d'améliorer la précision de la mesure en réduisant la contribution des incertitudes systématiques. Cette mesure ainsi que la mesure du taux de charme permettent respectivement de contraindre l'hypothèse de la factorisation dans les calculs de la Heavy Quark Effective Theory (HQET), et les paramètres de la chromodynamique quantique (QCD), tels que le rapport des masses des quarks et l'échelle de renormalisation.
76

Installation et mise en oeuvre d'un détecteur de rayons X à pixels hybrides sur un diffractomètre de laboratoire : applications aux études de densité électronique et aux expériences de cristallographie résolues en temps / Installation and commissioning of a hybrid pixels X-ray detector on a laboratory diffractometer : Applications to electron density studies and time-resolved crystallography

Wenger, Emmanuel 29 May 2015 (has links)
Par rapport aux détecteurs de rayons X couramment utilisés pour la cristallographie, les détecteurs à pixels hybrides apportent des avantages majeurs qui proviennent principalement de l’utilisation d'une chaîne de comptage propre à chaque pixel permettant de compter les photons individuellement et très rapidement. Les principales innovations de ces détecteurs sont les suivantes : (1) Suppression quasi totale du bruit ; (2) Obturateur électronique ultra rapide (de l'ordre de 100 ns) ; (3) Vitesse d'acquisition de 500 images par seconde. Ces avantages déjà mis à profit depuis une petite dizaine d’années sur les lignes synchrotron, sont également très prometteurs pour les diffractomètres de laboratoire. L’objet de la thèse a été de développer un diffractomètre expérimental de laboratoire équipé d’un détecteur à pixels hybrides, XPAD, et de réaliser les premières mesures de diffraction sur monocristal. Ces mesures ont permis de déterminer les corrections et calibrations du détecteur nécessaires pour les mesures sur monocristaux. Conjointement, les méthodes et techniques de traitement des images pour intégrer les intensités de diffraction ont été étudiées. L’intérêt du très faible bruit du détecteur pour l’étude de modèles de densité électronique a été démontré ; le prototype avec le détecteur XPAD a donné de meilleurs résultats que les diffractomètres usuels. Une deuxième application a consisté à utiliser les qualités de vitesse du détecteur pixel pour la mise en œuvre de mesures résolues en temps à l’échelle de la milliseconde. Des mesures sous champs électrique commuté ont permis de montrer le potentiel de ce type de détecteur dans ce domaine de recherche / Compared to X-ray detectors commonly used for crystallography, hybrid pixels detectors provide major advantages primarily due to the use of a counting system proper to each pixel allowing for very fast and individual photon counting. The main innovations of these detectors are: (1) Almost total suppression of noise ; (2) Ultra-fast electronic shutter (about 100 ns) ; (3) Acquisition rate of 500 images per second. These advantages have already been exploited over the past ten years on synchrotron beam lines and are also very promising for laboratory diffractometers. The thesis work was to realize a prototype laboratory diffractometer equipped with such a detector, XPAD, and to achieve single crystal X-ray diffraction measurements. The necessary corrections and calibrations of the detector required for diffraction measurements on single crystals were determined. The methods and image processing techniques to integrate the diffraction intensities were studied. Benefits of the very low noise of the detector for electron density models study were demonstrated; the prototype diffractometer equipped with an XPAD detector gave better results than conventional diffractometers. A second type of application was to use the pixel detector for the implementation of time-resolved diffraction measurements at millisecond timescale. Measurements under switched electric fields have shown the potential of this type of detector in this area of research
77

Efficacité de détection en tomographie d'émission par positrons: une approche par intelligence artificielle

Michaud, Jean-Baptiste January 2014 (has links)
En Tomographie d'Émission par Positrons (TEP), la course à la résolution spatiale nécessite des détecteurs de plus en plus petits, produisant plus de diffusion Compton avec un impact négatif sur l’efficacité de détection du scanner. Plusieurs phénomènes physiques liés à cette diffusion Compton entachent tout traitement des coïncidences multiples d'une erreur difficile à borner et à compenser, tandis que le nombre élevé de combinaisons de détecteurs complexifie exponentiellement le problème. Cette thèse évalue si les réseaux de neurones constituent une alternative aux solutions existantes, problématiques parce que statistiquement incertaines ou complexes à mettre en œuvre. La thèse réalise une preuve de concept pour traiter les coïncidences triples et les inclure dans le processus de reconstruction, augmentant l'efficacité avec un minimum d'impact sur la qualité des images. L'atteinte des objectifs est validée via différents critères de performance comme le gain d'efficacité, la qualité de l'image et le taux de succès du calcul de la ligne de réponse (LOR), mesurés en priorité sur des données réelles. Des études paramétriques montrent le comportement général de la solution : un réseau entraîné avec une source générique démontre pour le taux d'identification de la LOR une bonne indépendance à la résolution en énergie ainsi qu'à la géométrie des détecteurs, du scanner et de la source, pourvu que l'on ait prétraité au maximum les données pour simplifier la tâche du réseau. Cette indépendance, qui n'existe en général pas dans les solutions existantes, laisse présager d'un meilleur potentiel de généralisation à d'autres scanners. Pour les données réelles du scanner LabPET[indice supérieur TM], la méthode atteint un gain d'efficacité aux alentours de 50%, présente une dégradation de résolution acceptable et réussit à recouvrer le contraste de manière similaire aux images de référence, en plus de fonctionner en temps réel. Enfin, plusieurs améliorations sont anticipées.
78

Etude de nanojonctions Josephson à haute température critique en vue d'applications térahertz

Wolf, Thomas 10 December 2010 (has links) (PDF)
Nous avons développé une nouvelle technique de fabrication de jonctions Josephson à haute température critique réalisées par implantation ionique. Ces jonctions ont été caractérisées électriquement et modélisées par une simulation des équations quasi-classiques d'Usadel. Après développement d'un circuit de couplage dans les gammes 4-8 GHz et dans la gamme des quelques centaines de GHz, des mesures de mélange micro-onde ont été réalisées. Les résultats ont fait apparaître un terme non-linéaire d'amplitude importante absent des équations du modèle RSJ (« resistively-shunted junctions »). Une théorique basée sur la non-linéarité de la résistance normale des jonctions fabriquées par irradiation a été formulée et comparée avec les expériences. Elle permet d'ouvrir des perspectives intéressantes concernant les applications de détection micro-onde de ce type de jonctions Josephson.
79

Etude de la structure de noyaux riches en neutrons à l'aide de nouvelles sondes

Sauvan, E. 31 October 2000 (has links) (PDF)
Le cadre de ce travail est l'étude de la structure de noyaux légers riches en neutrons par différentes méthodes expérimentales et théoriques.<br /><br />Nous présentons tout d'abord une étude complète des réactions de perte d'un neutron effectuée sur les noyaux de $^{12-15}$B, $^{14-18}$C, $^{17-21}$N, $^{19-23}$O et $^{22-25}$F avec la mesure des distributions en moment parallèle et transverse et des sections efficaces sur cibles de C et de Ta.<br />Un modèle de type Glauber et de dissociation coulombienne, couplé à des calculs de modèle en couches, ainsi q'un nouveau modèle utilisant l'approximation soudaine pour le calcul des distributions transverses, ont été développés.<br />Les résultats de ces calculs sont en très bon accord avec les données, ce qui nous a permis de proposer des spins-parités pour les noyaux de $^{15}$B, $^{17}$C, $^{19-21}$N, $^{21,23}$O et $^{23-25}$F et de conclure quant à l'emploi de telles réactions comme outil spectroscopique.<br /><br />Les distributions en moment des alphas et la section efficace suivant la dissociation de l'$^6$He sur une cible de proton ont été mesurées. Les observations concordent avec des prédictions théoriques montrant la sensibilité de ces distributions à la structure du continuum de l'$^6$He.<br /><br />Enfin, pour le première fois, nous avons réalisé une expérience de capture radiative d'un proton sur l'$^6$He à 40 MeV/nucléon. La capture sur l'$^6$He avec formation du $^7$Li a été observée avec une section efficace de 35 $\pm$ 2 $\mu$b et la distribution angulaire des photons mesurée. Des coïncidences triples ($^6$Li, photons de 30 MeV et de 3.5 MeV) et doubles ($^4$He, photons de 27 MeV) ont aussi été observés. Elles peuvent être interprétées comme des captures du proton sur des sous-systèmes de l'$^6$He ($^5$He et $^4$He), ou comme des captures sur l'$^6$He avec formation de résonances du $^7$Li. De faibles indications expérimentales ainsi que l'observation d'un petit nombre de coïncidences deutons et photons de 22 MeV vont dans le sens de la première hypothèse.
80

Mesures des rayons cosmiques entre le GeV et le PeV par les expériences AMS et CREAM

Brinet, Mariane 21 November 2007 (has links) (PDF)
Les expériences AMS et CREAM, toutes deux dédiées à la détection des rayons cosmiques, sont différentes dans leur mode de fonctionnement, mais complémentaires à de nombreux égards. Elles ont une architecture très similaire, relativement proche de celle des détecteurs de physique des particules utilisés dans les accélérateurs. Toutes deux comportent un imageur Cherenkov. Ils permettent de déterminer la charge, et le cas échéant la vélocité (pour AMS), des particules qui traversent le détecteur, avec une très bonne résolution pour des noyaux d'atomes allant de l'hydrogène au Fer.<br /><br />Dans l'élaboration et la construction de tels instruments, deux composants majeurs doivent faire l'objet d'attention et d'études particulières : d'une part le matériau radiateur utilisé pour générer les photons Cherenkov - dans le cas d'AMS et de CREAM, il s'agit d'aérogel de silice - et d'autre part les photomultiplicateurs, cellules de détection des photons ainsi produits. C'est la connaissance précise de son indice de réfraction qui détermine les performances des imageurs Cherenkov. Une étude complète a donc été consacrée à la mesure précise de l'indice de réfraction des tuiles d'aérogel qui composent le plan radiateur aussi bien du compteur d'AMS que de celui de CREAM. <br />Ce sont ces études, et en particulier l'élaboration de méthodes de détermination de l'indice et leurs adaptations au fur et à mesure des conclusions obtenues, qui font l'objet principal de ce document. <br /><br />Le premier chapitre aborde quelques-uns des enjeux de la physique des rayons cosmiques concernés par les mesures aussi bien d'AMS que de CREAM. Les quelques pages de ce chapitre ne font pas la liste complète de tous les apports des expériences AMS et CREAM à la physique des rayons cosmiques, loin de là, mais ne font qu'en dévoiler certains aspects, en guise de prélude aux pages plus techniques qui suivent, consacrées exclusivement à de l'instrumentation. Le second chapitre, après une brève introduction du détecteur AMS et des spécificités de son imageur Cherenkov (RICH, pour Ring Imaging CHerenkov), détaille les méthodes utilisées pour cartographier l'indice de réfraction du plan d'aérogel. La caractérisation de l'aérogel du sous-détecteur CHERCAM (CHERenkov CAMera) de l'expérience CREAM, dont l'entière construction a été réalisée entre 2005 et 2006, est exposée dans le chapitre trois. Enfin une dernière partie présente rapidement certains aspects des travaux de simulation et de préparation à l'analyse de données, et trace les perspectives à court et moyen terme.

Page generated in 0.1011 seconds