• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 133
  • 39
  • 24
  • 2
  • Tagged with
  • 196
  • 79
  • 71
  • 50
  • 33
  • 32
  • 26
  • 26
  • 25
  • 23
  • 22
  • 22
  • 20
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Algorithmes numériques en temps réel appliqués à l'identification de cristaux et à la mesure de l'estampe du temps scanner TEP/TDM tout-numérique à base de photodiodes à avalanche

Semmaoui, Hichman January 2009 (has links)
La tomographie d'émission par positrons (TEP) est devenue un outil important dans les diagnostics de la médecine nucléaire. Avec le développement et l'utilisation de différents radiotraceurs qui permettent de visualiser les processus métaboliques et les structures organiques par des procédés non invasifs, les caméras TEP cliniques sont largement utilisées et fournissent une résolution spatiale et temporelle suffisante pour les diagnostics humains. De plus, la recherche en pharmacologie et en médecine sont d'autres champs d'applications en développement. En effet, par l'utilisation de la TEP dans les expérimentations avec des petits animaux, l'efficacité de nouveaux médicaments peut être facilement vérifiée. Cependant, le problème avec les tomographes TEP pour petits animaux est la nécessité d'une résolution spatiale et temporelle beaucoup plus grande que celle pour les examens cliniques sur les humains. Ceci requiert de nouveaux concepts de détecteurs et de traitement de signal dans le développement des systèmes TEP dédiés pour les petits animaux. En outre, ces concepts sont complémentés, pour résoudre ce problème, par la fusion d'une image morphologique (tomodensitométrie-TDM) à une image métabolique (TEP). Le LabPET[exposant TM], un scanner TEP dont l'aspect bimodal TEP/TDM est en développement. Ce scanner, dédié aux petits animaux, est développé à l'Université de Sherbrooke. Il utilise des photodiodes à avalanche (PDA) connectées individuellement à des scintillateurs et combinés à de nouveaux algorithmes numériques. Ce scanner vise à répondre aux besoins relatifs à la résolution spatiale et temporelle de l'imagerie TEP pour petits animaux. Dans cette thèse, de nouveaux algorithmes sont développés et testés afin d'augmenter la résolution spatiale et temporelle du LabPET. L'augmentation de la résolution spatiale est basée sur des algorithmes d'identification de cristaux, excités, au sein d'un détecteur multicristaux. Tandis que, l'augmentation de la résolution temporelle est basée sur un concept de déconvolution utilisant le résultat de l'identification de cristaux.
112

Regulation of power amplifiers under VSWR conditions in CMOS 65nm for 60GHz applications

Gorisse, Jean 15 November 2010 (has links) (PDF)
Avec l'apparition d'applications grand-public, comme le Wireless-HD, les fréquences millimétriques nécessitent l'utilisation de technologies CMOS faible coût. Cependant, avant d'être commercialisés, les transmetteurs mmW doivent être suffisamment résistants notamment à la désadaptation d'impédance entre l'amplificateur de puissance (AP) et l'antenne qui peut résulter d'un obstacle dans le champ proche de l'antenne. Une telle désadaptation d'impédance se traduit par l'apparition d'ondes stationnaires qui peuvent engendrer des dommages irrémédiables sur l'AP. Cette thèse propose une architecture innovante de régulation qui vise à protéger l'AP de telles dégradations tout en optimisant ses performances. La désadaptation d'impédance peut être évaluée en intégrant plusieurs détecteurs de puissance entre l'AP et l'antenne. Une boucle de régulation numérique peut ensuite établir une stratégie d'optimisation des performances de l'AP. Cette thèse s'intéresse particulièrement aux circuits de détection de puissance qui captent la désadaptation d'impédance de l'antenne. Réalisé en technologie CMOS 65nm de STMicroelectronics, le détecteur de puissance présente 25dB de dynamique à 60GHz et est capable de détecter jusqu'à 3 :1 de TOS. Ces détecteurs de puissance ont ensuite été intégrés dans un second circuit avec un AP et des convertisseurs (CAN & CNA). Une boucle de régulation agissant sur le gain de l'AP permet ainsi de garder une puissance de sortie constante quelle que soit l'impédance d'antenne tandis qu'une seconde boucle protège l'AP de la destruction. Cette thèse couvre également deux projets développés en parallèle de l'architecture de régulation de TOS. D'abord est proposée une nouvelle architecture de convertisseur analogique numérique logarithmique, basée sur l'architecture d'amplificateur logarithmique à compression progressive. Ensuite, une co-simulation sous ADS d'un AP RF/mmW avec sa boucle de régulation numérique permet de simuler l'AP à TOS régulé.
113

Réalisation de jonctions ultra-minces par recuit laser : application aux détecteurs UV

Larmande, Yannick 23 November 2010 (has links) (PDF)
Depuis les années 1970, la taille des composants n'a cessé de diminuer. La réalisation de jonctions ultra-minces et fortement dopées est devenue un point clef dans la réduction des dispositifs microélectroniques. Les techniques de production doivent évoluer afin de répondre aux spécifications drastiques, en termes de taille des zones dopées et de leurs propriétés électriques, des prochains noeuds technologiques. Dans ce travail de thèse nous avons étudié le procédé d'activation au laser de dopants implantés par immersion plasma. Le laser à excimère utilisé (ArF) est absorbé dans moins de 10 nm de silicium, ce qui va permettre un recuit local. De plus, la courte durée d'impulsion va assurer un faible budget thermique, limitant la diffusion des dopants. En associant cette technique à l'implantation ionique par immersion plasma, dont l'intérêt est de pouvoir travailler à de très basses tensions d'accélération (quelques dizaines d'eV), nous pouvons réaliser des jonctions avec un fort taux d'activation sans diffusion. Après avoir présenté les différentes techniques de dopage pouvant être utilisées, nous avons décrit les dispositifs expérimentaux de traitement et de caractérisation utilisés. Des simulations ont permis de comprendre le rôle des paramètres laser sur le profil de température du silicium en surface. Après avoir choisi le laser le plus adapté parmi les lasers ArF, KrF et XeCl (respectivement : 193 nm - 15 ns, 248 nm - 35 ns, 308 nm - 50 ns), nous avons observé l'effet du nombre de tirs et de la mise en forme de faisceau afin d'optimiser le procédé. Pour terminer, des inhomogénéités dues aux bords de faisceau ont été mises en évidence et étudiées afin d'en limiter l'effet.
114

Analyse et modélisation de la réponse des détecteurs du projet PICASSO pour la recherche de la matière sombre

Plante, Arthur 11 1900 (has links)
Les mesures cosmologiques les plus récentes ont montré la présence d’un type de matière exotique constituant 85% de la masse de l’univers. Ce type de matière non baryonique serait formé de particules neutres, non relativistes, massives et interagissant faiblement avec la matière baryonique. L’ensemble des candidats est regroupé sous le nom générique WIMP (Weakly Interactive Massive Particles). L’expérience PICASSO (Projet d’Identification des CAndidats Supersymétriques de la matière SOmbre) est une expérience utilisant des détecteurs à seuil d’énergie contenant des gouttelettes surchauffées constituées de C4F10. Cette technique de détection est basée sur le principe de la chambre à bulles. Le projet PICASSO a pour but de détecter directement une particule de matière sombre. Le principe de détection est qu’une particule de matière sombre interagissant avec le liquide actif engendre un recul nucléaire du 19F. L’énergie de recul serait suffisante pour engendrer une transition de phase accompagnée d’un signal acoustique enregistrée par des senseurs piézoélectriques. Dans le cadre de ce mémoire, une simulation du taux de comptage de l’étalonnage des détecteurs PICASSO soumis à des neutrons monoénergétiques a été effectuée en utilisant la théorie de Seitz qui décrit les critères pour qu’une transition de phase ait lieu pour un liquide en état de surchauffe. De plus, un modèle calculant le signal acoustique émis lors d’une transition de phase engendré par différents types de radiations a été créé permettant de caractériser la discrimination entre différents bruits de fond en fonction de l’énergie de seuil. Finalement, un outil d’analyse, la localisation des évènements, a été utilisé pour appliquer des coupures sur le volume dans le but d’améliorer la discrimination alpha-neutron. / The latest cosmological measurement showed the presence of a type of exotic matter constituing of 85% mass-energy of the universe. This type of non-baryonic matter would consist of neutral, non-relativistic, massives particules which are weakly interacting with normal matter. All the candidates are grouped under the generic name of WIMPs (Weakly Interactive Massive Particles). The PICASSO project (Project In CAnada to Search for Supersymmtric Objects) is an experiment using superheated liquid C4F10 as target material. The detection principle is a variant of the bubble chamber technique and the experiment ins installed in the SNOLAB underground laboratory in Sudbury (Ontario). The goal of this project is to make a direct measurement of a dark matter particle. The detection principle is that a dark matter particule interacting with the active liquid produces a nuclear recoil of 19F. The energy deposition of the recoiling fluorine nucleus triggers a phase transition accompagnied by an acoustic signal recorded by piezoelectrics sensors. In this work, the simulation of the count rate of PICASSO detectors subjected to monoenergetic neutron beam was performed using the theory of Seitz which describes particle induced phase transitions in supherheated liquids. which describes the criteria for a phase transition to occur in a superheated liquid. In addition, a model calculating the acoustic signal emitted during a phase transition caused by different types of radiation has been developped which allowed the characterisation of the discrimination between different kind of background events as a function of threshold energy. Finally, an acoustic signal analysis tools, the localisation of events, was used to apply fiducial cuts to the detectors in order to improve the alpha-neutron discrimination.
115

Nouvelles chaînes d'instrumentation intégrées multivoies pour l'astrophysique / New integrated multi-channel instrumentation for astrophysics

Bouyjou, Florent 05 December 2011 (has links)
L'exploration du système solaire et l'étude de l'univers lointain sont encore sources de découvertes et de mystère pour la communauté scientifique et pour l’humanité en général. Ces observations sont actuellement principalement basées sur la mesure d’ions et de particules in-situ qui constituent ces milieux. Les instruments d’observation intègrent des détecteurs spatiaux, utilisés pour convertir l'énergie des particules en charges électriques mesurables. Ces derniers sont étroitement liés à leur électronique analogique ou Analog-Front-End (AFE) et cette combinaison forme des chaines astrophysiques de détection appelées « sensor heads ». Depuis quelques années, la volonté d’améliorer les résolutions spatiale et spectrale des détecteurs nécessite la conception d’une électronique intégrée multivoies. Ainsi, une électronique spatiale de type Application Specific Integrated Circuit (ASIC) doit être développée. Cela permet d’une part de s’adapter au mieux à chaque détecteur pour en optimiser les performances ; et d’autre part de bénéficier des multiples avantages inhérents à l’utilisation d’une technologie CMOS : diminuer les dimensions et les temps de transit des signaux, intégration multifonctions, réduction des coûts pour une fabrication de masse et effets parasites étudiés et bien connus. Cependant les contraintes spatiales exigent une qualification draconienne du circuit. En effet, ces environnent radiatifs peuvent endommager les systèmes électroniques embarqués à bord des missions spatiales. Grâce à la réduction des dimensions, il ne semble plus opportun aujourd’hui d’utiliser des technologies dédiées au spatial (type SOI ou biCMOS spécifiques) mais plutôt de mettre en œuvre des techniques de durcissement par design (RHBD) sur des technologies standards qui sont moins onéreuses et plus performantes. L’objectif de cette thèse est la conception de nouvelles chaînes d’instrumentations intégrées multivoies pour le spatial. Ce travail, co-financé par le CNES et le CNRS, s’est inscrit dans le cadre d’un projet soutenu par le Réseau Thématique de Recherche Avancée Sciences et Technologies pour l’Aéronautique et l’Espace (RTRA STAE) entre 2008 et 2011, intitulé CASA (Chaines AStrophysiques et leur instrumentation Associée). Au cours de cette thèse nous avons conçu 2 ASICs associés à 2 types de détecteurs spatiaux bien distincts. Le premier permet de compter les électrons en sortie d’une microchannel plate (MCP) tandis que le deuxième permet de quantifier le niveau d’énergie perdu par les e- en pénétrant dans un SC. L’étude de ces différents détecteurs doit d’abord être faite afin de les modéliser pour une parfaite adéquation avec leur électronique de détection. Ensuite, une optimisation des chaînes de conversion en vitesse, bruit et consommation est réalisée. Enfin, une méthodologie de savoir faire au niveau du traitement des informations doit être développée pour pérenniser l’expérience emmagasinée durant ces travaux. / The solar system exploration and study of the distant universe are still sources of discovery and mystery to the scientific community and for humanity in general. These observations are currently mainly based on the measurement of ions and particles in-situ forming these environments. The observation instruments incorporate spatial sensors, used to convert particles energy into electrical charges measurable. These are closely related to their electronic analog or Analog-Front-End (AFE) and the combination form chains astrophysical detection called "sensor heads". In recent years, the desire to improve the spatial and spectral resolution detectors requires the design of a multichannel integrated electronics. Thus, a spatial-type electronic Application Specific Integrated Circuit (ASIC) should be developed. This allows one hand to best adapt to each detector to optimize performance, and on the other hand to benefit from multiples advantages inherent in the use of CMOS technology: reducing the size and transit time signals, multi-function integration, cost reduction for mass production and interference effects studied and well known. However, the spatial constraints require a drastic qualification of the circuit. Indeed, the surrounding radiation can damage electronic systems on board the space missions. By reducing the size, it seems more appropriate today to use technologies for the space (or BiCMOS SOI specific) but rather to implement hardening design techniques (RHBD) on standard technologies that are less expensive and more efficient. The objective of this thesis is the design of new integrated multi-channel instrumentation for space. This work, co-funded by CNES and CNRS, has registered as part of a project supported by the Advanced Research Thematic Network Science and Technology for Aeronautics and Space (RTRA STAE) between 2008 and 2011, called CASA (Channels Astrophysics and their associated instrumentation). In this thesis we have designed two ASICs associated with two types of distinct space detectors. The first is used to count the electrons at the output of a MicroChannel Plate (MCP) and the second quantifies the amount of energy lost by e- by entering in a SC. The study of these different sensors must first be made to model them for a perfect match with their detection electronics. Then the chain optimization in conversion speed, noise and consumption is achieved. Finally, a methodology of knowledge in the processing of information must be developed to sustain the experience stored in this work.
116

Méthodes statistiques de reconstruction tomographique spectrale pour des systèmes à détection spectrométrique de rayons X / Spectral CT statistical reconstruction methods for X-ray photon-counting detectors system

Rodesch, Pierre-Antoine 09 October 2018 (has links)
La tomographie à rayons X est une technologie d’imagerie en trois dimensions. Elle se base sur la transmission de rayons X à travers l’objet d’étude. Elle est non destructive mais néanmoins irradiante. Cette technique de visualisation est utilisée principalement dans trois domaines : le diagnostic médical, le contrôle non destructif (détection de défauts dans des pièces industrielles de haute performance) et la sécurité (contrôles aéroportuaires des bagages). Les récentes avancées technologiques dans le domaine des détecteurs spectrométriques de rayons X ouvrent des perspectives d’amélioration de cette technique d’imagerie dans ses divers domaines d’application. Nous avons développé une nouvelle méthode reconstruction statistique appelée MLTR-ONE-STEP qui permet de reconstruire la variabilité énergétique du coefficient linéaire d’atténuation de l’objet étudié. Cette approche est dite « one-step » car elle reconstruit directement le volume final à partir des mesures brutes issues de détecteurs spectrométriques.Les phénomènes physiques au sein du détecteur provoquent une distorsion énergétique du spectre d’atténuation qui a été prise en compte lors de la reconstruction. La méthode utilisée s’inscrit dans le cadre bayésien et maximise la log-vraisemblance du modèle tout en prenant en compte de l’a priori spatial sur le volume reconstruit. L’objectif de la méthode est l’amélioration de la qualité de l’image finale (réduction des artefacts et niveau de bruit) et la quantification des matériaux présents. Nous avons étudié dans le cadre de données simulées l’influence des paramètres de régularisation sur la reconstruction. En pratique, le détecteur de rayon X étudié classe les photons incidents en 64 canaux. Ils sont ensuite regroupés en un nombre de canaux plus faible (2 à 25) et l’influence de ce regroupement a été étudiée. La reconstruction MLTR-ONE-STEP a ensuite été testée sur des données expérimentales regroupées en 12 canaux. / X-ray spectral tomography is a 3D visualization technique. It is based on the transmission of X-rays through object matter. It is a non-destructive technology but which irradiates the studied object/patient. X-ray tomography is mainly used in three areas: medical diagnosis, non-destructive testing (detection of defects in industry devices) and airport security (luggage screening). New technological breakthroughs in X-ray photon-counting detectors provide new perspective for improving this technique in each application field. We have developed a new reconstruction method named MLTR-ONE-STEP which enables the obtention of energetic variability of the scanned object linear attenuation coefficient. This approach belongs to the “One-Step” class because it directly reconstructs the final images from raw photon-counting detector data.Physical effects inside the detector are causing spectral distortion of the energetic spectrum. This distortion is taken into account in our reconstruction through a Detector Response Matrix. The developed reconstruction method maximizes the poissonian likelihood of the measurements with a spatial regularization Tukey term. The objectives of spectral tomography are the improvement of the image quality compared to standard tomography and the quantification of materials inside the object. We have studied the influence of regularization parameters on the final result. In practice, photon-counting detector measurements are in practice sorted in 64 energy bins. Bins are then merged in a smaller number (from 2 to 25). The influence of this binning was studied on simulated data. The MLTR-ONE-STEP was then tested on real experimental data in order to prove the feasibility of such a “One-Step” reconstruction method.
117

Développement et réalisation d'un circuit de microélectronique pour le détecteur spatial de rayons cosmiques JEM-EUSO / Development and design of a microelectronic circuit for space-borne JEM-EUSO cosmic rays detector

Ahmad, Salleh 29 November 2012 (has links)
Extreme Universe Space Observatory on Japanese Experiment Module (JEM-EUSO) est conçu comme l’expérience de rayons cosmiques de prochaine génération pour observer les particules hautement énergétiques au-dessus de 10²⁰ eV. Le projet est mené par RIKEN et soutenu par une collaboration de plus de 200 membres provenant de 13 pays. Cet observatoire, sous la forme d'un télescope fluorescent, sera arrimé à la Station Spatiale internationale (ISS) pour un lancement prévu en 2017. En observant les gerbes atmosphériques produites dans la troposphère, à une altitude de 400 km, cet observatoire de rayons cosmique offrira une grande surface de détection, qui est au moins 100 fois supérieur que le plus grand détecteur de rayons cosmiques jamais construit. La surface focale de JEM-EUSO sera équipée d'environ 5000 unités de photomultiplicateur multianode 8x8 pixels (MAPMT). Un circuit intégré (ASIC), connu sous le nom SPACIROC, a été proposé pour la lecture du MAPMT. Cet ASIC de 64 voies propose des fonctionnalités comme le comptage de photons, la mesure des charges et le transfert de données à haute vitesse. Par-dessus tout, cet ASIC doit peu consommé afin de respecter la contrainte de puissance de JEM-EUSO. Réalisé en utilisant la technologie AMS Silicium-Germanium (SiGe) 0,35 µm, cet ASIC intègre 64 canaux de comptage de photons rapides (Photon Counting). La résolution de temps pour le comptage de photons est de 30 ns, ce qui permettra d’atteindre la valeur maximale comptage qui est de l'ordre de 10⁷ photons / s. Le système de mesure de charge est basé sur le Time-Over-Threshold qui offre 8 canaux de mesure. Chaque canal de mesure est une somme des 8 pixels du MAPMT et il est prévu que ce système est capable de mesurer jusqu'à 200 pC. La partie numérique fonctionne en continu et gère la conversion des données de chaque voie des blocs de Photon Counting et Time-Over-Threshold. Les données numériques sont transmises par l'intermédiaire de liaisons parallèles dédiées et ces opérations sont effectuées pendant une fenêtre de communication ou « Gate Time Unit » (GTU) de fréquence 400 kHz. Le taux de transfert des données d’ASIC avoisine les 200 Mbps ou 576 bits / GTU. La dissipation de puissance est strictement inférieure à 1 mW par canal ou 64 mW pour l'ASIC. Le premier prototype de SPACIROC a été envoyé pour fabrication en Mars 2010 au Centre Multi Projet (CMP). Des puces nues et packagés ont été reçues en Octobre 2010, ce qui a débuté la phase de caractérisation de cet ASIC. Après une phase de test réussie, des puces SPACIROC ont été intégrés dans l'électronique frontale d'un instrument pour détecter les sursauts gamma - Ultra Fast Flash Observatoire (UFFO) qui va être lancé en 2013. Vers la fin de l'année 2012, des cartes électroniques frontales conçues autour des puces SPACIROC ont été fabriqués pour le projet EUSO-Balloon. Ce projet de vol en ballon stratosphérique à une altitude de 40 km servira comme le démonstrateur technologique et l'ingénierie d'un instrument miniaturisé JEM-EUSO. La deuxième génération de cet ASIC a été envoyée à la fonderie en Décembre 2011. Ce second prototype, SPACIROC2, a été testé à partir de mai 2012. Les principales améliorations sont les suivantes: la consommation d'énergie a été revue à la baisse, ainsi que l'amélioration de la résolution temporelle de Photon Counting et l'extension de la gamme dynamique pour le module Time-Over-Threshold. Les mesures en cours ont montré que SPACIROC2 présente un bon comportement général et apporte des améliorations par rapport à son prédécesseur. / Extreme Universe Space Observatory on Japanese Experiment Module (JEM-EUSO) is conceived as the next generation cosmic rays experiment for observing the highly energetic particles above 5.10¹⁹ eV. The project is lead by RIKEN and supported by an active collaboration of more than 200 members from 13 countries. This observatory, in the shape of a wide field-of-view UV telescope, will be attached to the International Space Station (ISS) for a planned launch in 2017. Observing the Air Showers generated in troposphere from an altitude of 400 km, this space based cosmic rays experiment will offer a very large instantaneous detection surface, which is at least 100 times bigger than the largest land based cosmic rays observatory. The detection surface of JEM-EUSO will be equipped with around 5000 units of 8x8 pixels Multianode Photomultiplier (MAPMT). A radiation hardened mixed signal application-specific integrated circuit (ASIC), known as SPACIROC, has been proposed for reading out the MAPMT. This ASIC features 64-channel analog inputs, fast photon counting capabilities, charge measurements and high-speed data transfer. Above all, the power dissipation of this ASIC is required to be very low in order to comply with the strict power budget of JEM-EUSO. By taking the advantages of high speed AMS 0.35 µm Silicon-Germanium (SiGe) process, this ASIC integrates 64 fast Photon Counting channels. The photon counting time resolution is 30 ns, which allows the theoretical counting rate in the order of 10⁷ photons/s. The charge measurement system is based on Time-Over-Threshold which offers 8 measurement channels. Each measurement channel is composed of 8 pixels of the MAPMT and it is expected that this system will measure up to 200 pC. The digital part is then required to operate continuously and handles data conversion of each Photon Counting and Time-Over-Threshold channel. For the first version of this ASIC, one channel measurement channel for the dynode is also available. The digital data are transmitted via dedicated parallel communication links and within the defined Gate Time Unit (GTU) of 400 kHz frequency. The ASIC data output rate is in the vicinity of 200 Mbps or 576 bits/GTU. The power dissipation is kept strictly below 1 mW per channel or 64 mW for the ASIC. The first prototype of SPACIROC was sent for tapeout in March 2010 through Centre Multi Projet (CMP) prototyping services. The packaged ASICs and bare dies have been received in October 2010 which marked the characterization phase of this chip. After successful testing phase, SPACIROC chips were integrated into the front-end electronics of an instrument pathfinder for detecting the gamma ray bursts – Ultra Fast Flash Observatory (UFFO) which is foreseen to be launched in 2013. Towards the end of 2012, front-end board designed around SPACIROC chips have been fabricated for the EUSO-Balloon project. This balloon borne project will serve as a technical and engineering demonstrator of a fully miniaturized JEM-EUSO instrument which will be flown to the stratosphere at the altitude of 40 km. The second tapeout of this ASIC was done in December 2011. This second prototype, SPACIROC2, was tested from May 2012. The main improvements are as follows: lower power consumption due to better power management, enhancement in Photon Counting time resolution and extension the Time-Over-Threshold maximum input rate. The ongoing tests have shown that SPACIROC2 exhibits a good overall behavior and improvement compared to its predecessor.
118

Encapsulation couche mince des dispositifs photovoltaïquesorganiques / Thin film encapsulation of organic photovoltaic devices

Broha, Vincent 31 January 2019 (has links)
L’oxygène et l’eau présents dans l’atmosphère sont des acteurs important dans la dégradationdes matériaux contenus dans les dispositifs opto-électroniques organiques. Dans le but d’améliorerla stabilité et la durée de vie de ces dispositifs, ces dispositifs sont encapsulés avec desmatériaux barrière aux gaz par lamination ou par l’utilisation de couches minces. Cette dernière,notamment utilisée pour les OLED, permet de fournir des barrières aux gaz performantes parle dépôt de couches inorganiques denses directement sur les dispositifs. Cependant, elles sontassujetties aux défauts des surfaces sur lesquelles elle sont déposées.L’objectif de ces travaux est de développer une couche de planarisation afin d’homogénéiserla surface des dispositifs photovoltaïques organiques (OPV) et de réduire la rugosité dans lebut d’obtenir une protection barrières aux gaz améliorée, conférée par le dépôt subséquent decouches denses inorganiques selon divers moyens (voie liquide et gazeuse).Dans un premier temps, des couches de planarisation ont été développées à partir de 6 copolymèresp(VDF-HFP). Ces derniers ont été caractérisés afin d’améliorer nos connaissances sur cesmatériaux.Grâce à une étude de solubilité, des encres à différentes concentrations dans l’acétate d’éthyleont été réalisées. Ces dernières ont été étudiées par des mesures rhéologiques et de tension desurface permettant de mieux appréhender leur étalement, et les états de surface obtenus sur dessubstrats PET et sur les dispositifs OPV. Ces recherches ont été complétées par un contrôlede la topographie et par conséquent de la planarisation des dispositifs OPV par microscopieconfocale.Pour finir, l’étude des performances barrière des structures d’encapsulations hybrides (organiqueinorganique)ont dévoilé une bonne compatibilité lorsque la rugosité de la couche de planarisationest très faible. Ces résultats sont confirmés par des mesures barrières aux gaz et des tests devieillissement accélérés des dispositifs OPV encapsulés en enceinte climatique qui permettentd’illustrer l’intérêt de l’encre planarisante développée.Ce travail a été réalisé au laboratoire LMPO au CEA/LITEN en collaboration avec l’industrielArkema dans le but de fournir des technologies d’encapsulations performantes. / Oxygen and water present in the atmosphere are important actors of the degradation of materialscontained in optoelectronic devices. In order to increase the stability and the lifetime ofOPV, the devices are encapsulated with gas-barrier materials by lamination encapsulation orthin film encapsulation. These latter, espacially used in OLED technology, provides high performancegas barriers by depositing dense inorganic layers directly onto the devices. However,they are subject to the defects of the surfaces on which they are deposited.The purpose of this study is to develop a planarinzing layer in order to homogenize the surfaceof organic photovoltaic devices (OPV) and to reduce the roughness with the aim to obtain animproved gas barrier protection, conferred by the subsequent deposition of dense inorganic layersby various ways (liquid and gaseous routes).In a first step, the planarization layers were developed from six p(VDF-HFP) co-polymers. Thesehave been characterized to improve our knowledge on those materials.Through a solubility study, inks at different concentrations in ethyl acetate were made. Thelatter were studied by rheological measurements and surface tension to understand better theirspread, and the surface conditions obtained on PET substrates and OPV devices. Those researchswere completed with a topography control and consequently the planarization of OPVdevices by confocal microscopy.Finally, the study of the barrier performance of hybrid encapsulation structures (organic-inorganic)revealed a good compatibility when the rugosity of the planarization layer is very low. Theseresults are confirmed by permeation measurements and accelerated aging tests of OPV devicesencapsulated in climatic chambers that illustrate the interest of the planarized ink developed.This work has been performed in the LMPO Laboratory at CEA/LITEN in collaboration withthe chemical company Arkema in order to be able to provide performant encapsulation technologies.
119

Détecteurs spectrométriques pour la mammographie et traitement associés / Signal processing methods for energy sensitive mammography exams

Pavia, Yoann 23 May 2017 (has links)
Nous avons étudié l’utilisation de détecteurs spectrométriques, qui émergent dans le domaine de l’imagerie médicale, pour leur application à la mammographie. Ces détecteurs permettent de discriminer l’énergie des photons reçus, ce qui apporte une information supplémentaire à l’imagerie d’atténuation traditionnelle. Ainsi, il est possible d’utiliser des techniques de décomposition en base de deux matériaux, notamment pour déterminer la densité glandulaire dans le sein, qui correspond au pourcentage de tissus glandulaires, et qui est un facteur de risque pour le développement d’un cancer, à partir d’une seule irradiation. Jusqu’alors, il était possible d’utiliser cette méthode à partir de deux expositions à deux énergies distinctes. Dans certains cas, une nouvelle tendance consiste à pratiquer des mammographies avec injection d’un produit de constratse iodé, mais cela nécessite également au moins deux irradiations. Nous avons donc proposé d’estimer la densité du sein et la concentration d’iode simultanément, à partir d’une seule irradiation, à une dose 0,93 mGy, en appliquant des méthodes de décomposition en base de trois matériaux. Premièrement, des méthodes polynomiales ont été adaptées pour être comptibles avec l’information spectrale provenant de 3 canaux d’énergies. Ensuite, nous avons montré qu’une deuxième approche, capable de prendre en compte une information spectrale plus fine, basée sur la maximisation de la vraisemblance entre un spectre mesuré et des spectres de références, était capable d’atteindre de meilleurs résultats. Enfin, nous avons développé une méthode capable de prendre en compte la compression du sein en mammographie pour améliorer les résultats obtenus par la méthode de maximum de vraisemblance. / Energy sensitive X-ray detectors are emerging in the field of medical imaging. We have investigated the use of this new type of X-ray detectos for their application to mammography exams. These detectors are able to discriminate the energy of received photons, which provides additional information to a standard mammography image only composed of the total attenuation signal. Thus, these detectors allow the use of basis material decomposition techniques, from a single x-ray exposure, and permit to determine the breast density, which corresponds to the percentage of glandular tissues in the breast. Breast density is known for being a risk factor for the development of breast cancers. Without energy sensitive X-ray detectors, this method requires two X-ray exposures at different energies. Contrast enhanced mammography is also developing but it requires the use an iodinated contrast media and at least two irradiations. Hence, we proposed to take benefit of energy-sensitive detectors to simultaneously estimate the breast density and the iodine concentration, using a single X-ray exposure at a mean glandular dose of 0.93 mGy. This approach is based on three basis material decomposition methods. First, different polynomial methods have been adapted to comply with spectral information from 3 energy channels. Then, we showed that a second approach, based on the maximisation of the likelihood between a measured spectrum and reference spectra, was able take into consideration finer spectral information and achieved better results. Finally, we have developed a method that can take into consideration the thickness of the compressed breast during a mammography exam to improve the results obtained by the maximum likelihood method.
120

Depletion of CMOS pixel sensors : studies, characterization, and applications / Désertion de capteurs à pixels CMOS : étude, caractérisations et applications

Heymes, Julian 17 July 2018 (has links)
Une architecture de capteurs à pixels CMOS permettant la désertion du volume sensible par polarisation via la face avant du circuit est étudiée à travers la caractérisation en laboratoire d’un capteur prototype. Les performances de collection de charge confirment la désertion d‘une grande partie de l’épaisseur sensible. De plus, le bruit de lecture restant modeste, le capteur présente une excellente résolution en énergie pour les photons en dessous de 20 keV à des températures positives. Ces résultats soulignent l’intérêt de cette architecture pour la spectroscopie des rayons X mous et pour la trajectométrie des particules chargées en milieu très radiatif. La profondeur sur laquelle le capteur est déserté est prédite par un modèle analytique simplifié et par des calculs par éléments finis. Une méthode d’évaluation de cette profondeur par mesure indirecte est proposée. Les mesures corroborent les prédictions concernant un substrat fin, très résistif, qui est intégralement déserté et un substrat moins résistif et mesurant 40 micromètres, qui est partiellement déserté sur 18 micromètres mais détecte correctement sur la totalité de l’épaisseur. Deux développements de capteurs destinés à l’imagerie X et à la neuro-imagerie intracérébrale sur des rats éveillés et libres de leurs mouvements sont présentés. / An architecture of CMOS pixel sensor allowing the depletion of the sensitive volume through frontside biasing is studied through the characterization in laboratory of a prototype. The charge collection performances confirm the depletion of a large part of the sensitive thickness. In addition, with a modest noise level, the sensor features an excellent energy resolution for photons below 20 keV at positive temperatures. These results demonstrate that such sensors are suited for soft X-ray spectroscopy and for charged particle tracking in highly radiative environment. A simplified analytical model and finite elements calculus are used to predict the depletion depth reached. An indirect measurement method to evaluate this depth is proposed. Measurements confirm predictions for a thin highly resistive epitaxial layer, which is fully depleted, and a 40micrometers thick bulk less resistive substrate, for which depletion reached 18 micrometers but which still offers correct detection over its full depth. Two sensor designs dedicated to X-ray imaging and in-brain neuroimaging on awake and freely moving rats are presented.

Page generated in 0.0544 seconds