• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 456
  • 59
  • 37
  • 31
  • 29
  • 29
  • 29
  • 15
  • 14
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 556
  • 206
  • 128
  • 68
  • 67
  • 62
  • 62
  • 58
  • 57
  • 52
  • 46
  • 45
  • 45
  • 43
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação da exposição ocupacional ao 222Rn no galpão da salvaguardas do IPEN / ASSESSMENT OF 222Rn OCCUPATIONAL EXPOSURE AT IPEN NUCLEAR MATERIALS STORAGE SITE

Lilian Saueia Caccuri 18 October 2007 (has links)
Neste trabalho foi avaliada a exposição ao 222Rn para os trabalhadores que executam atividades no galpão da Salvaguardas do ipen, por meio da estimativa da dose efetiva comprometida recebida por esses indivíduos. Para tanto foram determinadas as concentrações de 222Rn no interior do galpão da Salvaguardas pelo método de detecção passiva com detectores de traços nucleares do estado sólido (SSNTD). O detector utilizado foi o policarbonato Makrofol E de 1 cm2, inserido em uma câmara de difusão do tipo KFK. Foram monitorados 14 pontos no interior de galpão e um ponto externo durante um período total de 21 meses, trocando-se os detectores a cada três meses, entre Dezembro de 2004 e Setembro de 2006. As concentrações de 222Rn obtidas variaram entre 196 ± 9 e 2048 ± 81 Bq/m3. A dose efetiva comprometida devido à inalação de radônio no galpão da Salvaguardas do IPEN foi calculada, de acordo com os procedimentos da Comissão Internacional de Proteção Radiológica (ICRP) a partir da quantidade de 222Rn incorporada e de um fator de conversão de dose. Os resultados obtidos encontram-se abaixo do limite anual de 20 mSv/a, estabelecido pela ICRP 60, para indivíduos ocupacionalmente expostos. / In this study it was assessed the occupational exposure to 222Rn at ipen nuclear materials storage site through the committed effective dose received by workers exposed to this radionuclide. The radiation dose was calculated through the radon concentrations at nuclear materials storage site. Radon concentrations were determined by passive detection method with solid state nuclear detectors (SSNTD). The SSNTD used in this study was the policarbonate Makrofol E; each detector is a small square plastic of 1 cm2, placed into a diffusion chamber type KFK. It was monitored 14 points at nuclear materials storage site and one external point, over a period of 21 months, changing the detectors every three months, from December 2004 to September 2006. The 222Rn concentrations varied from 196 ± 9 e 2048 ± 81 Bq·m-3. The committed effective dose due to radon inhalation at IPEN nuclear materials storage site was obtained from radon activity incorporated and dose conversion factor, according to International Commission on Radiological Protection procedures. The effective committed dose received by workers is below 20 mSv·y-1. This value is suggested as an annual effective dose limit for occupational exposure by ICRP 60.
32

Irregularly sampled data in the design of a soft sensor system: some preliminary results

Griesing-Scheiwe, Fritjof 08 February 2019 (has links)
In modern industrial applications, sensors are an expensive part of installed systems. Nevertheless, many system variables cannot be measured sufficiently frequently or accurately. Thus, soft sensors have been developed to estimate those variables without the expense of additional hardware. The use of a soft sensor with a bias update term has shown to perform well for disturbed systems with time delays and multirate sampling times. In industrial application, the time delay and sampling times often vary. Yet, the case of variation of the time delay and sampling time in the bias update term has not been considered in previous publications. This thesis tests a soft sensor with bias update term in simulation and gives a modification yielding better performance. It is shown that the tested method gives unstable results. Hence, a more general method with a bias update term that considers all possible sampling times in each step is proposed, giving stable results in simulation. Furthermore, the stability of the general method is proven mathematically by building a state space representation and applying the Bauer-Premaratne-Dur´an theorem to the stability of switching systems. / Tesis
33

Fabricação e caracterização de sensor de pixel ativo com tecnologia NMOS de porta metalica / Fabrication and characterization of active pixel sensors using metal gate NMOS technology

Furtado, Andre Santos de Oliveira 15 August 2018 (has links)
Orientadores: Jose Alexandre Diniz, Davies William de Lima Monteiro / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-15T05:03:14Z (GMT). No. of bitstreams: 1 Furtado_AndreSantosdeOliveira_M.pdf: 1676950 bytes, checksum: 4a916b5f14986722791efe6f19d7618a (MD5) Previous issue date: 2009 / Resumo: Sensores de Pixel Ativo (APS) baseados em tecnologia nMOS simples e com alta razão de aspecto podem apresentar boa sensibilidade para fotodetecção e oferecer uma opção de baixo custo para circuitos de sensoreamento de imagens. Neste trabalho são apresentados o leiaute, fabricação e caracterização de fotodiodos, transitores e APSs construídos no Centro de Componentes Semicondutores (CCS). Todas as etapas do projeto foram realizadas no CCS, incluindo as máscaras litográficas, fabricadas em um processo óptico. Foi utilizado um processo nMOS de 5[j,m, de porta metálica, com uma camada de metal para interconexões e apenas quatro níveis de litografia. Os dispositivos apresentam resultados satisfatórios e compatíveis ao comportamento previsto em simulações SPICE, indicando que podem obter bom desempenho em circuitos para aplicações específicas, como sensores ópticos de posição e sensores de frente de onda, em diversas áreas, como astronomia, oftalmologia e microscopia de força atômica (AFM) / Abstract: Active Pixel Sensors (APS) based on a simple nMOS technology with high aspect ratio may present good sensitivity to photodetection and offer a low cost option for image sensing circuits. This work presents the layout, fabrication and characterization of photodiodes, transistors and APSs built at the Center for Semiconductor Components (CCS). All the process stages took place in CCS, including the manufacturing of the lithography masks through an optical process. The technology used was an nMOS, 5[j,m, metal gate, with a single metal layer for interconnections and only four lithography levels. The devices presented satisfactory results, compatible to the behavior predicted by SPICE simulations, suggesting a good performance in application specific circuits, such as optical position sensitive detectors and wavefront sensors, and in several fields, such as astronomy, ophthalmology and atomic force microscopy (AFM) / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica
34

Eletrodos impressos modificados com poli-histidina aplicados na construção de sensores eletroquímicos para crômio(VI) e fármacos /

Bergamini, Márcio Fernando. January 2007 (has links)
Orientador: Maria Valnice Boldrin Zanoni / Banca: Hideko Yamanaka / Banca: Orlando Fatibello Filho / Banca: Mauro Bertotti / Banca: Auro Atsushi Tanaka / Resumo: O presente trabalho investiga a aplicação de eletrodos impressos, de carbono (SPCE) e ouro (SPGE), na determinação de espécies de interesse farmacêutico, tais como, aurotiomalato, L-dopa e procaína, utilizando sistemas convencionais, com fluxo de solução e análise por injeção em fluxo, respectivamente. Após a otimização de todos os parâmetros voltamétricos e inerentes da técnica construí-se curvas analíticas para cada composto farmacêutico com respostas lineares entre concentrações de 1,4 x 10-6 a 1,5 x 10-4 mol L-1, 1,5 x 10-6 a 6,6 x 10-4 mol L-1 e 1,0 x 10-5 a 1,0 x 10-4 mol L-1 para o aurotiomalato, a L-dopa e a procaína, respectivamente. O método foi aplicado na determinação dessas espécies em formulações farmacêuticas. A construção e caracterização voltamétrica de. eletrodos de carbono impresso (SPCE) por filmes de poli-histidina (PH) foi também investigada com intuito de ampliar o nível de sensibilidade e seletividade dos métodos voltamétricos. Para isso, foram testados três diferentes procedimentos de para a construção dos eletrodos modificados: a adição direta de uma solução do polímero (SPCE/PH), a utilização de uma reação cruzada entre a poli-histidina e o glutaraldeído (SPCE/Glu-PH) e a eletropolimerização a partir do monômero histidina (SPCE/EPH). O comportamento voltamétrico dos eletrodos modificados mostrou-se fortemente dependente do procedimento de preparação dos filmes. Eletrodos SPCE/PH e SPCE/Glu-PH apresentaram uma alta eficiência na pré-concentração de ânions, como o ferricianeto. Não sendo observado nenhum efeito eletrocatalítico para a oxidação de ácido ascórbico com esses eletrodos. Já para o SPCE/EPH foi observado um baixo desempenho na pré-concentração de ânions, mas um pronunciado efeito eletrocatalítico para a oxidação de ácido ascórbico. A aderência e estabilidade das respostas obtidas...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present work investigated the application of screen-printed carbon (SPCE) and screen-printed gold electrodes (SPGE) in the determination of species of pharmaceutical interest, such as, aurothiomalate, L-dopa and procaine. The performance of all electrodes was tested in a conventional electrochemical system, and also in two electrochemical cells using amperometric detection. The first one was constructed to operate on hydrodynamic system and the second one to work on flow injection analysis (FIA) system. Analytical curves were obtained for all systems with linear relationship from peak current vs concentration from 1.4 x 10-6 to 1.5 x 10-4 mol L-1 for aurothiomalate; 1.5 x 10-6 to 6.6 x 10-4 mol L-1 for L-dopa and 1.0 x 10-5 to 1.0 x 10-4 mol L-1 for procaine, respectively. The method was tested in pharmaceutical compounds with good recovery. Screen-printed carbon electrodes (SPCE) can be easily modified with poly-histidine (PH) films using three different procedures: by direct addition of a poly-histidine solution on the electrode surface (SPCE/PH), using a cross-link reaction between poly-histidine and glutaraldehyde (SPCE/Glu-PH) and by electropolymerization of the histidine monomer (SPCE/EPH). The voltammetric behavior of the three modified electrodes was evaluated using potassium hexacyanoferrate(III) and ascorbic acid as model compounds. All modified electrode from stable films, but SPCE coated by deposition of PH and Glu-PH presented higher efficiency for pre concentration anions, while SPCE coated by electropolymerization of the monomer (EPH) presented pronounced electrocatalytic effect in the ascorbic acid oxidation. The resulting PH films presented good adherence and high stabilities and they were applied in the voltammetric analysis of isoniazide, pyrazinamide, aurothiomalate and chromium (VI). The best experimental condition for isoniazide and pyrazinamide...(Complete abstract click electronic access below) / Doutor
35

Estudo e desenvolvimento de sensores biomiméticos baseados em materiais carbonáceos modificados com ftalocianinacobalto (II) para detecção amperométrica de metribuzin /

Figueira, Eduardo Carneiro. January 2012 (has links)
Orientador: Maria Del Pilar Taboada Sotomayor / Banca: Iara Lucia Tescarollo Dias / Banca: Emerson Schwingel Ribeiro / Resumo: O presente trabalho está baseado na construção de sensores biomiméticos para monitoramento sensível e seletivo do agrotóxico metribuzin (MTZ). Para isto, eletrodos à base de pasta de carbono e nanotubos de carbono foram modificados com diversos complexos potenciais catalisadores biomiméticos das enzimas P450, que são enzimas que catalisam um grande número de reações incluindo os agrotóxicos. O complexo que apresentou perfil biomimético e melhores resultados na determinação amperométrica do metribuzin foi à ftalocianinacobalto (II) [CoPc]. Quando construídos sensores à base de pasta de carbono modificada com CoPc, os melhores resultados foram obtidos usando 15% (m/m) de complexo na preparação da pasta e realizando as medidas em tampão Britton-Robinson 0,08 mol L-1 (pH 2,0), aplicando potencial de -690 mV vs Ag|AgCl. Sob estas condições obteve-se uma faixa linear de resposta de 2,4 x 10-5 a 2,0 x 10-4 mol L-1, com uma boa sensibilidade e LOD e LOQ de 4,3 x 10-6 e 1,4 x 10-5 mol L-1, respectivamente. Estudos relacionados a elucidar a biomimeticidade do sensor, incluíram avaliação da influência da velocidade de varredura empregando voltametria cíclica, exploração do perfil hiperbólico da resposta do sensor e estudo de interferentes e de seletividade. A seguir, foi avaliada a influencia de nanotubos de carbono de paredes múltiplas (MWCNT) na preparação da pasta no intuito de tentar aumentar a detectabilidade do sensor modificado com ftalocianinacobalto (II). Entretanto, os resultados obtidos não foram àqueles esperados, devido principalmente, à grande quantidade de material aglutinante (Nujol® que é isolante) necessário para a obtenção da pasta. Assim, a seguir, foi realizada a avaliação de eletrodos impressos à base de grafite, contendo MWCNT a 0,3% e CoPc a 5%, 10% e 15% (m/m). Sob as condições de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work is based on the construction of biomimetic sensors for monitoring sensitive and selective pesticide metribuzin (MTZ). For this, the base electrodes of carbon paste and carbon nanotubes have been modified with various complex catalysts potential biomimetic of P450 enzymes, which are enzymes that catalyze a large number of reactions including pesticides. The complex profile that showed better results in biomimetic and amperometric determination of metribuzin was the ftalocianinacobalto (II) [CoPc]. When constructed sensors based on a modified carbon paste CoPc with the best results were obtained using 15% (m/ m) complex in the preparation of the folder and making the measurements in Britton-Robinson buffer 0,08 mol L-1 (pH 2,0), by applying potential to -690 mV vs Ag | AgCl. Under these conditions gave a linear response range of 2.4 x 10-5 to 2.0 x 10-4 mol L-1, and with good sensitivity and LOQ and LOD of 4,3 x 10-6 and 1 , 4 x 10-5 mol L-1, respectively. Related studies to elucidate the biomimeticidade sensor, included evaluation of the influence of scan rate using cyclic voltammetry, exploitation of hyperbolic profile of the sensor response and the study of interferences and selectivity. Next, we evaluated the influence of carbon nanotubes multi-walled (MWCNT) in the preparation of the folder in order to try to increase the detectability of the sensor modified with ftalocianinacobalto (II). However, the results were not those expected, mainly due to the large amount of binder material (Nujol ® which is an insulator) necessary for obtaining the paste. Thus, the following evaluation was made electrodes printed based on graphite containing MWCNT CoPc 0,3% and 5%, 10% and 15% (m / m). Under the above conditions optimized for the analysis carbon paste, the printed electrode that provided the best... (Complete abstract click electronic access below) / Mestre
36

Desenvolvimento de sistem biomimético para análise de 3,5,6-Tricloro-2-piridinol, o principal metabólito do clorpirifós /

Santos, André Luiz dos. January 2012 (has links)
Orientador: Maria Del Pilar Taboada Sotomayor / Banca: Marcos Roberto de Vasconcelos Lanza / Banca: Rosa Amália Fireman Dutra / Resumo: O presente trabalho está baseado no desenvolvimento de um sistema biomimético para monitoramento sensível e seletivo do metabólito TCP (3,5,6-tricloro-2-piridinol), proveniente do agrotóxico clorpitifós, o qual é mais solúvel que o próprio agrotóxico e cuja ocorrência em águas subterrâneas e superficiais é mais provável e perigosa. Foi construído um sensor biomimético com detecção voltamétrica por onda quadrada, os eletrodos, foram confeccionados à base de pasta de carbono modificada com o complexo cloro-5,10,15,20-tetraquis(pentafluorofenil)-21H,23H-porfirina ferro (III), o qual apresenta uma estrutura química semelhante à do sítio ativo da enzima P450. O sensor construído apresentou as melhores respostas em tampão fosfato 0,20 mol L-1 e pH 6,0, usando a voltametria de onda quadrada a 50 Hz, 150 mV de amplitude e 1,5 mV de E. Com os parâmetros otimizados o sensor apresentou limites de detecção e de quantificação de 1,9 e 5,2 μmol L-1, respectivamente. Estudos realizados para averiguar a biomimeticidade do sensor, incluíram: velocidade de varredura por voltametria cíclica, exploração do perfil hiperbólico da resposta no sensor e avaliação da seletividade. O sensor foi satisfatoriamente usado na análise em diversos tipos de amostras de interesse ambiental. Foram feitos testes de recuperação e nas amostras de solo, águas superficiais e subterrâneas obtendo recuperação de 91%, 107% e 96% respectivamente, mostrando que o sensor pode ser usado como método alternativo para quantificação de TCP em diferentes matrizes. O sensor também foi empregado no monitoramento da eficiência de polímeros de impressão molecular (MIP) para TCP. Buscando obter o polímero biomimético mais eficiente para o analito, foram usadas ferramentas computacionais que permitiram escolher o melhor monômero (acrilonitrila)... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work is based on developing a biomimetic system for sensitive and selective monitoring of the TCP (3,5,6-trichloro-2-pyridinol), the principal metabolite of the pesticide chlorpyrifos, which is more soluble than the pesticide and whose occurrence in groundwater and surface water is more likely and dangerous. For this, a biomimetic sensor was constructed and the square wave voltammetric was used for measurements. The electrodes were fabricated using carbon paste modified with the complex chloro-5,10,15,20-tetrakis-(pentafluorophenyl)-21H,23H-porphyrin iron(III), which has a chemical structure similar to the active site of the enzyme P450. The sensor presented the best responses in phosphate buffer 0.20 mol L-1 and pH 6.0, using the square wave voltammetry with 50 Hz, amplitude of potential of 150 mV and ΔE of 1.5 mV. With the optimized parameters the sensor showed limits of detection and quantification of 1.9 and 5.2 μmol L-1, respectively. Studies conducted to investigate the mimicking of the sensor, included evaluation of the influence on scan rate in the cyclic voltammetry, the verification of the hyperbolic profile of the sensor response and evaluation of selectivity. The sensor has been satisfactorily applied in the analysis of different samples of environmental interest. Recovery experiments in samples of soil, surface water, and groundwater showed values of 91%, 107% and 96% respectively, showing that the sensor can be used as an alternative method for the quantification of TCP in different matrices. The sensor was also used to monitor the efficiency of molecularly imprinted polymers (MIP) for TCP. In order to obtain the most efficient biomimetic polymer to this analyte were used computational tools that allowed select the best monomer (acrylonitrile). In order to verify the results obtained by the theoretical... (Complete abstract click electronic access below) / Mestre
37

Métodos inéditos de interrogação óptica e suas aplicações na medição de grandezas físicas

Kitano, Cláudio. January 2016 (has links)
Banca: Amílcar Careli César / Banca: Josemir Coelho Santos / Banca: Marco Isaías Alayo Chávez / Banca: Aparecido Augusto de Carvalho / Banca: Ricardo Tokio Higuti / Resumo: Neste Texto Sistematizado, o candidato a Livre Docente expõe os principais resultados alcançados em sua trajetória após o doutorado, em termos de atividades de ensino, extensão, administrativas e de pesquisa. Ênfase especial é destinada à análise crítica das atividades de pesquisa e orientação de dissertações e teses junto ao Programa de Pós-Graduação em Engenharia Elétrica - PPGEE, da FE-IS UNESP. O enfoque principal da pesquisa refere-se à proposição teórica e experimental de novas técnicas de detecção de fase óptica empregando-se interferometria laser, e suas aplicações na medição de deslocamentos microscópicos, na caracterização de atuadores piezoelétricos flextensionais e em medições de tensões elétricas elevadas. A motivação para a realização da pesquisa, a exposição dos desafios e as soluções propostas são discutidas. Inserções em outras áreas, que envolvam sensores e sistemas ópticos, bem como, a cooperação com grupos de pesquisas afins, internos e externos à FE-IS UNESP, são apresentadas. No final, discutem-se as pesquisas atuais e as perspectivas futuras
38

Estudo morfológico e de transporte eletrônico em nanoestruturas de ZnO para aplicações em sensor /

Silva, Ranilson Angelo da. January 2016 (has links)
Orientador: Marcelo Ornaghi Orlandi / Banca: Silvio Rainho Teixeira / Banca: Neftal Lenin Villarreal Carreño / Banca: José Roberto Siqueira Junior / Banca: Regina Célia Galvão Frem / Resumo: A eficiência dos materiais semicondutores óxidos metálicos utilizados em dispositivos sensores, depende fortemente de parâmetros morfológicos e estruturais. É de grande interesse que os materiais apresentem um elevado grau nos parâmetros de medidas que definem um bom sensor, como: sinal, sensibilidade, seletividade. Devido a isso, métodos de sínteses adequados têm grande influência no desempenho dos dispositivos, já que interferem diretamente na morfologia e estrutura dos materiais semicondutores. Através dessa perspectiva, nesse trabalho, morfologias do composto semicondutor óxido metálico ZnO foram superficialmente modificadas com o intuito de realizar melhorias para aplicações em sensores de gás e de radiação luminosa (fotocondução) na faixa do ultravioleta. Dois métodos de sínteses foram utilizados: i) evaporação térmica por redução carbotérmica e ii) hidrotermal assistido por micro-ondas, responsáveis por obter morfologias tipo tetrapés e estrelas multipontas, respectivamente. Processos de evaporação térmica por redução carbotérmica tem a grande vantagem de obter estruturas com morfologias unidimensionais, em contrapartida, o método hidrotermal assistido por micro-ondas pode sintetizar uma enorme gama de diferentes morfologias com a vantagem de ser um processo rápido e de baixos custos energéticos. Técnicas como microscopia eletrônica de varredura, microscopia eletrônica de transmissão, difração de raios-X, espectroscopia ultravioleta visível e infravermelho, foram utili... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
39

Evaluación experimental de una fuente de radiación mixta (neutrón-gamma) de Am-Be para la calibración de detectores dosimétricos de neutrones

Miranda Contreras, Héctor Benigno January 2018 (has links)
En el presente trabajo el campo de neutrones producido por una fuente de neutrones de 241Am-Be es evaluado experimentalmente, debido que actualmente en el Perú no existe un laboratorio de Calibración de neutrones que preste servicios de calibración de equipos y detectores de neutrones térmicos. Además se describe los instrumentos y equipos utilizados en el proceso de detección de neutrones térmicos. La evaluación experimental se realiza en etapas, se usa varios elementos moderadores tales como parafina borada, polietileno y Cadmio a su vez se termalizan en diferentes geometrías como se muestran en la figuras 14, 15, 19 y 20. Mediante diferentes métodos tales como hojuelas Au197, CR-39 y TLD se obtienen flujos y dosis provenientes de la fuente isotópica, además mediante una serie de cálculos experimentales y teóricos (MCNP-4b) se determinan las características de la fuente isotópica Am-Be y del espectro gamma obtenido de un detector semiconductor de GeHP se puede determinar la energía gamma promedio. Se procede a realizar pruebas de reproducibilidad con las diferentes técnicas para obtener un mayor grado de precisión en los datos. Esta evaluación permite obtener datos para futuras calibraciones de equipos y/o detectores tales como CR-39, TLD y BF3 para monitoreo de personal expuesto a fuentes de neutrones provenientes de reactores nucleares, aceleradores lineales y fuentes portátiles así como para el monitoreo ambiental en caso de riesgo radiológico. Además se pretende con esta evaluación diseñar, construir, estudiar materiales para el blindaje, un sistema de irradiación de neutrones guardando todos los sistemas de seguridad que pide la AEIA. / Trabajo de suficiencia profesional
40

O mercado brasileiro para os sensores imageadores digitais suborbitais

Mello, Emanuele Teles Ouriques de January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil. / Made available in DSpace on 2012-10-19T22:30:43Z (GMT). No. of bitstreams: 1 199029.pdf: 5501100 bytes, checksum: 12ea7317f53708ca935b71a0586000da (MD5) / : Este trabalho aborda a inserção dos novos sensores aerotransportáveis digitais no mercado brasileiro avaliando suas características e potenciais. A utilização da Fotogrametria apresenta diversas vantagens, entre as quais o rápido trabalho de campo, exigindo um mínimo de permanência com equipes pequenas. Os argumentos mais marcantes a favor das câmaras eletrônicas atuais não estão centrados na qualidade da imagem, mas sim no prazo e na praticidade. Com uma câmara sem filme, pode-se ver uma imagem em instantes, às vezes segundos após capturá-la, e até mesmo escolher o melhor ângulo para obtê-la. A grande vantagem reside exatamente em eliminar o longo processo de obtenção da imagem via filme; evita-se o processo da revelação, digitalização do filme e trabalhos de edição da imagem na tela para obter uma versão digital de alta qualidade. Avaliando a qualidade da imagem (resolução espacial) e as características técnicas de cada tipo de sensor digital, percebe-se que ainda há campo para aperfeiçoamentos no que diz respeito ao custo e a qualidade de imagem. Para determinar a predisposição do mercado brasileiro em absorver estas novas tecnologias, fez-se uma pesquisa sobre as características de alguns destes novos sensores (DMC2001, ADS40, CASI, Laserscanner) e relacionou-as com os produtos oriundos do sistema em uso, utilizado como exemplo para este artigo o Sistema completo da Zeiss. A partir deste conhecimento, realizam-se as considerações quanto à utilização de sensores imageadores aéreos digitais não orbitais no mercado brasileiro, propriamente dita, envolvendo suas vantagens e desvantagens, certificação dos produtos; a mudança de paradigma; os custos; as aplicações; os clientes entre outros.

Page generated in 0.0188 seconds