61 |
Tratamento de varizes gástricas: mola e cianoacrilato versus cianoacrilato-estudo prospectivo randomizado / Treatment of gastric varices: coil plus cyanoacrylate versus cyanoacrylate alone. A randomized and prospective studyLôbo, Maíra Ribeiro de Almeida 24 March 2017 (has links)
A obliteração com cianoacrilato ainda é a técnica recomendada para tratamento das varizes gástricas, apesar do risco de embolia pulmonar. O tratamento ecoguiado com mola e cianoacrilato é uma alternativa recente, idealizado com o principal objetivo de diminuir a incidência de embolia. O presente estudo tem como objetivo comparar prospectivamente as duas técnicas quanto a incidência de complicações e a eficácia. Foram tratados pacientes com varizes gástricas pseudotumorais dos tipos GOV2 ou IGV1, em profilaxia primária ou secundária, sem tratamento endoscópico ou radiológico prévio. Os pacientes foram randomizados em dois grupos: grupo I - terapia ecoguiada com injeção de mola e cianoacrilato; grupo II - injeção não ecoguiada de cianoacrilato apenas. Tomografias computadorizadas para pesquisa de embolia foram realizadas em todos pacientes após o procedimento. Ecoendoscopia controle foi realizada com 1, 4 e 10 meses. O estudo foi realizado entre outubro de 2013 e novembro de 2016. O tempo médio de seguimento foi de 9,9 meses (1-26 meses). Foram avaliados 32 pacientes com idades entre 20 e 75 anos (média de 53,5 anos). Dezenove (59,4%) pacientes eram do sexo feminino. As etiologias da hipertensão portal mais encontradas foram a cirrose criptogênica, 7 (21,9%) e a hepatite C, 7 (21,9%). Vinte e cinco (78,1%) eram Child A e 7 (21,9%) Child B. Dezessete (53,1%) pacientes já tinham sangrado e 19 (59,4%) já haviam sido submetidos a tratamento endoscópico prévio de varizes esofágicas. Não houve diferença significante entre os dois grupos nas características acima citadas. Quanto aos achados endoscópicos e ecoendoscópicos, no grupo I, 13 (81,2%) pacientes apresentavam varizes gástricas do tipo GOV2 e 3 (18,8%) do tipo IGV1, números iguais aos achados no grupo II . O tamanho médio da variz gástrica foi de 3,62 cm ( ± 1,13) no grupo I e de 3,06 cm (± 0,88) no grupo II (p=0,131). A trombose imediata do vaso foi total em 6 (37,5%) pacientes no grupo I e em 8 (50%) pacientes no grupo II (p=0,476). No retorno em 30 dias, 11 (73,3%) pacientes no grupo I apresentavam ausência de fluxo no vaso tratado e 12 (75%) no grupo II (p=1). Quatro (26,7% e 25%) pacientes em cada grupo necessitaram de uma segunda sessão de tratamento em 30 dias (p=1). Após 4 meses, foi observada a trombose total do vaso tratado em 15 (100%) pacientes no grupo I e em 12 (80%) pacientes no grupo II (p=0,224). Dois (6,7%) pacientes foram a óbito no grupo II, sendo um decorrente de hemorragia digestiva alta e outro de sepse de foco indeterminado. No grupo I, 8 (50%) pacientes tiveram complicações precoces, sendo 4 (25%) casos de embolia pulmonar. No grupo II, 10 (62,5%) apresentaram complicações, com 8 (50%) casos de embolia . Não houve diferença significativa entre os dois grupos quanto ao índice de embolia pulmonar (p=0,144). Todos os pacientes que apresentaram embolia foram assintomáticos. Avaliando separadamente os pacientes com embolia pulmonar, não se observou diferença significante quanto ao grau de disfunção hepática, tipo da variz gástrica, número de sessões necessárias para a erradicação e a quantidade de ampolas de cianoacrilato utilizadas. Entretanto, o tamanho das varizes foi significativamente maior nos pacientes que tiveram embolia (3,85 cm ± 1,08) do que nos que não apresentaram essa complicação (3,04 cm ±0,9) (p=0,029). No grupo II, varizes maiores que 2,5 cm cursaram com maior incidência de embolia, com área sob a curva ROC de 0,836. O custo da injeção da mola com cianoacrilato foi significativamente maior que o do cianoacrilato (p < 0,001). Apesar da maior incidência de embolia no grupo I, não se observou significância estatística na comparação entre os dois grupos. A eficácia das duas técnicas se mostrou semelhante / In order to treat gastric varices, endoscopic obliteration using cyanoacrylate remains as the recommended technique, despite pulmonary embolism risk. EUS-guided coil treatment with cyanoacrylate is a recent alternative, designed with the main objective to decrease embolism incidence. This study aims at comparing these techniques regarding complication incidence and efficacy prospectively. Patients diagnosed with GOV2- or IGV1-pseudotumoral gastric varices were treated in primary or secondary prophylaxis, and no previous endoscopic or radiologic treatment. Patients were randomized into two groups: group I - EUS-guided coiling and cyanoacrylate injection treatment and group II - non EUS-guided cyanoacrylate injection alone treatment. Computed tomography was performed to identify embolism in all patients post-procedure. Control EUS examinations were performed at months 1, 4, and 10. This study was conducted from October 2013 to November 2016. Mean follow-up time was 9.9 months (1-26 months). Among the total of 32 patients aged 20 to 75 years old (mean age: 53.5 years) evaluated, 19 (59.4%) were female. Mostly found portal hypertension etiology was cryptogenic cirrhosis, in 7 (21.9%) patients, and hepatitis C virus, in 7 (21.9%). Twenty-five (78.1%) patients were categorized Child A and 7 (21.9%), Child B. Seventeen (53.1%) patients already presented with bleeding and 19 (59.4%) already underwent previous endoscopic esophageal variceal treatment. No significant difference between the two groups across the characteristics previously mentioned was found. Regarding endoscopic and ultrasound findings, in group I, 13 (81.2%) patients presented GOV2 gastric varices and 3 (18.8%), IGV1; whereas in group II, these same results were observed. Gastric variceal mean size was 3.62 cm (±1.13) in group I and 3.06 cm (±0.88) in group II (p=0.131). Immediate vessel thrombosis was found to be total in 6 (37.5%) patients from group I and in 8 (50%) from group II (p=0.476). At 30-day return visit, no flow in the treated vessel was verified in 11 (73.3%) patients from group I and 12 (75%) from group II (p=1). Four (26.7% and 25%) patients from both groups required second treatment session within 30 days (p=1). After 4 months, total thrombosis in the treated vessel was observed in 15 (100%) patients from group I and 12 (80%) from group II (p=0.224). Two (6.7%) group-II patients died: one from upper gastric hemorrhage and other from sepsis of undetermined focus. In group I, 8 (50%) patients presented early complications, 4 (25%) of them were cases of pulmonary embolism. In group II, 10 (62.5%) presented complications with 8 embolism cases. No significant difference between groups regarding pulmonary embolism index (p=0.144) was found. All embolism patients were asymptomatic. In a separate evaluation of pulmonary embolism patients, no significant difference was observed related to liver dysfunction degree, gastric varix type, number of sessions required for obliteration, and quantity of cyanoacrylate vials used. Nonetheless, variceal size was significantly higher in patients with embolism (3.85 cm ± 1.08) than in those with no such complication (3.04 cm ± 0.9) (p=0.029). In group II, varices larger than 2.5 cm evolved with higher incidence of embolism and the area under the ROC curve was found to be 0.836. Cost of coil injection with cyanoacrylate was significantly higher compared to cyanoacrylate alone (p < 0.001). Despite higher incidence of embolism in group I, no statistical significance in the comparison between groups was verified. Efficacy of both techniques was found to be similar
|
62 |
Applications of optical coherence tomography imaging in the assessment of glaucoma. / CUHK electronic theses & dissertations collectionJanuary 2006 (has links)
Although the current OCT imaging system was designed to examine the retinal structures, a novel application in imaging the anterior chamber angle was studied in section 3.7. OCT was demonstrated to be clinically useful for visualization of the different patterns of angle configurations in different forms of angle closure glaucoma. / In section 3.5, RNFL measurement by OCT was cross-validated by another nerve fiber analyzer, scanning laser polarimetry (SLP). While both OCT and SLP demonstrated comparable diagnostic performance for glaucoma detection and high correlation in the respective RNFL measurements, OCT was found to provide a closer estimation of RNFL thickness with reference to the reported histological measurements. In section 3.6, the structural-functional relationship between RNFL thickness and visual sensitivity was evaluated and compared between OCT and SLP. The relationships were found to be dependent on the choice of the perimetry scale, the type of RNFL measuring devices and the characteristics of the studied subjects. It was concluded that regression analysis of the structural-functional profile could provide important information in the assessment of the trend and pattern of glaucoma progression. / In summary, optical coherence tomography was shown to be useful in the diagnosis of glaucoma and in the evaluation of the trend and pattern of disease progression. / Objectives. The research project was designed to investigate the applications of optical coherence tomography in the assessment of glaucoma. The goals are to identify sensitive and specific anatomic markers, and analytical method for detection of glaucomatous changes, to evaluate the intricate structural-functional relationships in glaucoma with regression analysis and to assess the potential application of optical coherence tomography imaging system in visualization of the anterior chamber angle with a view to obtain OCT data to help understanding the pathophysiology of different forms of angle-closure glaucoma. / Sections 3.1 to 3.3 were designed to identify the most sensitive and specific diagnostic marker(s) for glaucoma detection. Peripapillary retinal nerve fiber layer (RNFL), macular thickness, optic nerve head parameters measured with different reference planes, and a novel anatomic marker - macular nerve fiber layer were investigated. The averaged peripapillary RNFL thickness measured with a high resolution scan (512 scan point) was found to have the best discriminating power for detection of glaucoma. It also has the strongest correlation with visual function. To examine if utilization of the complete data profile of peripapillary RNFL could further improve diagnostic sensitivity, a novel approach with the use of neural network trained to recognize RNFL pattern was studied in section 3.4. It was concluded that neural network analysis could enhance the diagnostic performance for glaucoma detection. / Summary. Glaucoma is a progressive optic neuropathy characterized by the loss of retinal ganglion cells resulting in constriction of visual field and loss of vision as the disease progresses. Since structural damage in glaucoma occurs well before any detectable loss in visual function, clinical examination of the optic nerve head and its nerve fiber layer is crucial in establishing the diagnosis, monitoring the progression and initiating treatment before irreversible damage takes place. The present research project is composed of 7 coherent studies (sections 3.1 to 3.7), aiming to investigate the clinical applications of optical coherence tomography (OCT), an advanced imaging device for detailed examination of optic nerve head and nerve fiber layer, in the assessment of glaucoma. / Leung Kai-shun. / "June 2006." / Adviser: Chi Pui Pang. / Source: Dissertation Abstracts International, Volume: 67-11, Section: B, page: 6323. / Thesis (M.D.)--Chinese University of Hong Kong, 2006. / Includes bibliographical references (p. 212-227). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Electronic reproduction. [Ann Arbor, MI] : ProQuest Information and Learning, [200-] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / School code: 1307.
|
63 |
Incontinência urinária em mulheres submetidas a estudo urodinâmico: variáveis associadas.Silva, Juliana Cristina Pereira da 19 February 2016 (has links)
Submitted by Fabíola Silva (fabiola.silva@famerp.br) on 2017-07-04T12:59:07Z
No. of bitstreams: 1
julianacristinapdasilva_dissert.pdf: 6143362 bytes, checksum: 40d299f2c23885568637781644986d64 (MD5) / Made available in DSpace on 2017-07-04T12:59:07Z (GMT). No. of bitstreams: 1
julianacristinapdasilva_dissert.pdf: 6143362 bytes, checksum: 40d299f2c23885568637781644986d64 (MD5)
Previous issue date: 2016-02-19 / Introduction: Urinary Incontinence (UI) is a common symptom at some stages of a
woman's life. It has an important negative impact on women's daily activities and can
adversely affect their quality of life. Objective: To investigate the profile of women
with urinary incontinence (UI) seen at an urological treatment center, according to the
type of UI present. Methods: This descriptive, exploratory, quantitative study was
conducted with 150 women with UI who had undergone urodynamic study at an
urological treatment center in Sao Jose do Rio Preto, SP, Brazil. The research
methodology followed for this research was based on the collection of primary and
secondary data, which were analyzed using univariate and multivariate analysis of
variance. Results: Most women were white (119-79.33%), overweight (68-45.33%),
homemakers (58-38.7%), and menopausal (80-53.3%); drank coffee (124-82.67%); did
not perform any physical activity (98-65.33%); and had urethral hypermobility (UH)
((91-60.67%). One hundred and forty-two women had gone through childbirth. There
were 331 deliveries, of which 54.98% were cesarean sections. We found a statistically
significant association between weight change and type of UI (p = 0.024); menopause
(p=0.001) and intrinsic sphincter deficiency (ISD) and detrusor instability (DI);
gynecological surgery and ISD and DI (p = 0.014); hysterectomy and all types of UI (p
= 0.040); and performance of physical activity and mixed UI (p = 0.014). Conclusion:
The obtained data suggest that the prevention and control of UI include measures such
as weight loss (decrease in BMI), exercise, pelvic floor-strengthening exercises and
improved care at primary healthcare level. This subject offers a fertile field for
investigation regarding diagnosis, treatment and new inter-and multiprofessional care
delivery models that improve the quality of life of women with UI. / Introdução: A Incontinência Urinária (IU) é um sintoma comum em algumas fases da
vida da mulher, com impacto negativo em suas atividades diárias e também
comprometendo sua qualidade de vida. Objetivo: Analisar o perfil de mulheres com
incontinência urinária (IU) atendidas em um serviço de urodinâmica, segundo o tipo de
IU que apresentam. Método Estudo descritivo, exploratório, quantitativo, realizado por
meio de coleta de dados primários e secundários de 150 mulheres que realizaram
elucidação da IU por meio de estudo urodinâmico em Centro de Diagnóstico e
Tratamento Urológico da cidade de São José do Rio Preto SP. Os dados foram
analisados por meio de técnicas de estatística uni e multivariada. Resultados: Entre as
mulheres avaliadas, a maioria era: branca (119 – 79,33%), com sobrepeso (68 –
45,33%), do lar (58 – 38,67%), na menopausa (80 – 53,33%), ingeriam café (124 –
82,67%), não faziam atividade física (98 – 65,33%) e apresentavam hipermobilidade
uretral (HU) (91 – 60,67%), Encontrou-se associação estatística significante entre
mudança de peso e HU(p=0,024), menopausa e deficiência esfincteriana intrínseca
(DEI) e instabilidade detrusora (ID) (P=0,001); ocorrência de cirurgia ginecológica com
DEI e ID (p=0,014), histerectomia e todos os tipos de IU (p=0,040) e realização de
atividade física com IU mista (p=0,014). Os dados sobre antecedentes obstétricos
mostraram que 142 mulheres passaram pelo processo da parturição, resultando em 331
partos, a maioria cesarianas (54,98%), Conclusão: O perfil analisado sugere que as
medidas de prevenção e controle da IU urinária seria uma diminuição do IMC, a prática
de atividade física, o desenvolvimento de exercícios para o fortalecimento do assoalho
pélvico e maior cuidado em nível de atenção básica de saúde. Também que é um amplo
campo de investigação nos aspectos de diagnóstico, terapêutica e outras diretrizes
assistenciais multi e interprofissionais, que contribuam para a melhoria da qualidade de
vida das mulheres afetadas.
|
64 |
Avaliacao dos criterios de qualidade de imagem e estudo das doses em um departamento de mamografia / Evaluation of the image quality criteria and study of doses in a mammography departmentALCANTARA, MARCELA C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:46Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
65 |
Modelo para determinacao de espessuras de barreiras protetoras em salas para radiologia diagnosticaCOSTA, PAULO R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:26Z (GMT). No. of bitstreams: 1
06634.pdf: 17873720 bytes, checksum: 7d4caa5b4a8bbc0193c8ee1522743f57 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
66 |
Determinacao das dimensoes do ponto focal de tubos de raios X utilizando um sensor CCD e o metodo das funcoes de transferenciasNERSISSIAN, DENISE Y. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:15Z (GMT). No. of bitstreams: 1
10189.pdf: 7945514 bytes, checksum: fc959ff6c97125fc66c813f5c29a3647 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
67 |
Conjuntos de reativos liofilizados de compostos diaminoditiolicos para marcacao com tecnecio-99m .Estudo farmacocinetico e elaboracao de modelos compartimentalizados dos respectivos complexosARAUJO, ELAINE B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:37Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:27Z (GMT). No. of bitstreams: 1
06044.pdf: 6865948 bytes, checksum: a08cf9df31bad7efc0884ad8cc855442 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
68 |
Desenvolvimento de método para separação química de gálio-67 pela técnica de difusão térmica / Development of method to chemical separation of gallium-67 by thermal diffusion techniqueMARTINS, PATRICIA de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:06Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
69 |
Contaminação microbiana de carcaças de frangos obtidas em dois sistemas de abate e avaliação de um protocolo de Reação em Cadeia de Polimerase (PCR) para detecção de Salmonella spp. / Microbiological control in chicken carcasses from two slaughter systems and evaluation of a Polymerase Chain Reaction (PCR) methodology for Salmonella spp. detectionMatias, Beatriz Garbelotti 19 December 2008 (has links)
Made available in DSpace on 2015-03-26T13:46:39Z (GMT). No. of bitstreams: 1
texto completo.pdf: 662232 bytes, checksum: af7e8ce650eb7e98bfec292cda8d020b (MD5)
Previous issue date: 2008-12-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The quality control in food industries is a global requirement, and in chicken slaughtering is conducted primarily through monitoring of hygiene indicator microorganisms and pathogens in specific processing steps. This need requires the development and application of rapid and reliable methods to be used in quality control. This study evaluated the differences in the microbiological contamination of chicken carcasses obtained at different processing steps from two distinct slaughterhouses (Ab1, classified as large-scale, and Ab2, small-scale). Still, a PCR methodology for detection of Salmonella spp. was compared to the conventional method (CM). Surface samples of chicken carcasses were collected in the following sequential steps: A) immediately before evisceration, B) after evisceration, C) after showering and D) after a cooling tank (chiller). All samples were tested for microbiological hygiene indicators (mesophilic aerobes - MA, total coliforms - TC, thermotolerant coliforms - TTC and Escherichia coli - EC) and Salmonella spp. In addition, Salmonella spp. was detected by PCR directly from the sample (PCR-S), from the pre-enrichment broth immediately after inoculation (PCR-PE) and from pre- enrichment broth after incubation (PCR-PEI). No significant differences were observed between the frequencies of Salmonella spp. obtained at different steps in Ab1 and Ab2 (P > 0.05). Ab2 showed higher levels of microbiological contamination in different steps of processing when compared to Ab1, for MA (in B and D steps), TC and TTC (D step) and EC (all steps) (P < 0.05). Regarding PCR, PCR-PEI showed higher sensitivity when compared to PCR-S and PCR-PE, despite the absence of significant difference when compared to the CM (P > 0.05). The results indicate the significance of different processing steps during slaughter in the microbiological contamination of chicken carcasses, and the necessity of development and evaluation of alternative methods for Salmonella spp. detection. / O controle de qualidade em indústrias alimentícias é uma exigência mundial, e em abatedouros de aves é conduzido basicamente pelo monitoramento de microrganismos indicadores de higiene e patógenos em pontos específicos da linha de processamento. Essa necessidade demanda o desenvolvimento e aplicação de metodologias rápidas e confiáveis a fim de serem utilizadas no controle de qualidade. Neste estudo foram avaliadas as diferenças na contaminação microbiana em carcaças de frangos obtidas em diferentes etapas do processamento em dois abatedouros (Ab1, classificados como de grande porte e Ab2, de pequeno porte). Ainda, uma metodologia de reação em cadeia da polimerase (PCR) para detecção de Salmonella spp. foi comparada com a metodologia convencional (MC). Amostras superficiais de carcaças de frangos foram coletadas nas seguintes etapas: A) imediatamente antes da evisceração, B) após a evisceração, C) após o chuveiro, e D) após o tanque de resfriamento (chiller). Todas as amostras coletadas foram submetidas à pesquisa de bactérias indicadoras de higiene (aeróbios mesófilos - AM, coliformes totais - CT, coliformes termotolerantes - CTT e Escherichia coli - EC) e Salmonella spp. A pesquisa de Salmonella spp. por PCR foi realizada diretamente das amostras (PCR-A), do caldo do pré- enriquecimento recém-semeado (PCR-PE) e do caldo de pré- enriquecimento após incubação (PCR-PEI). Não foram observadas diferenças significativas entre as freqüências de Salmonella spp. obtidas pela MC em diferentes etapas do processamento em Ab1 e Ab2 (P > 0,05). Verificou-se maior contaminação em Ab2 em relação a Ab1 por AM (nas etapas B e D), CT e CTT (etapa D) e EC (todas as etapas) (P < 0,05). Em relação à metodologia de PCR avaliada, verificou-se maior sensibilidade da PCR-PEI em relação às demais variações (PCRA e PCR-PE), porém não se constatou diferença significativa com a MC (P > 0,05). Os resultados obtidos indicam a importância de diferentes etapas do processamento na contaminação microbiana de carcaças de frangos em diferentes sistemas de abate e a necessidade de avaliação de metodologias alternativas a serem utilizadas na pesquisa de Salmonella spp.
|
70 |
Avaliacao dos criterios de qualidade de imagem e estudo das doses em um departamento de mamografia / Evaluation of the image quality criteria and study of doses in a mammography departmentALCANTARA, MARCELA C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:46Z (GMT). No. of bitstreams: 0 / Os critérios de qualidade de imagem mamógrafica publicados pela European Commission foram implementados em três mamógrafos de um mesmo departamento de radiologia de um hospital na cidade de São Paulo. Dentre os mamógrafos dois apresentam o sistema tela-filme e um deles apresenta o sistema digital indireto. Durante o período de coleta de dados, foi observada a necessidade de realizar um estudo sobre índice de rejeição de imagem em cada mamógrafo. Portanto, este estudo foi realizado e, em seguida, foram feitas comparações, entre os mamógrafos, do índice de rejeição de imagem e da porcentagem de imagens que atendiam a cada critério de qualidade de imagem. Paralelamente a esses estudos, foi realizado o estudo das doses na entrada da pele e glandular média. Essas doses foram estimadas, baseando-se em diferentes metodologias apresentadas por diferentes grupos de estudiosos, para todas as combinações anodo-filtro apresentadas pelo equipamento. Para estimar a dose na entrada da pele pelo método publicado no guia da ANVISA e a dose glandular média pelo método de Wu, foi desenvolvido um manequim no formato bem próximo ao de uma mama, em diferentes espessuras de PMMA. Por fim, associou-se a qualidade da imagem com a dose recebida pela paciente. O equipamento digital apresentou melhores resultados na avaliação dos critérios de qualidade, menor índice de rejeição de imagem e menores valores de dose glandular média e na entrada da pele em todos os métodos estudados. Porém não é suficiente, pois não atende às pacientes que possuem mamas grandes. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
Page generated in 0.0385 seconds