• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 385
  • 13
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 403
  • 207
  • 59
  • 44
  • 44
  • 40
  • 36
  • 36
  • 34
  • 34
  • 31
  • 30
  • 28
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Comparação entre métodos de inspeção não-destrutiva aplicados a peças compósitas laminadas sólidas estruturais aeronáuticas / Comparing nondestructive inspection methods applied to aeronautical grade solid structural composite laminated parts

Miranda, Marcos 27 June 2011 (has links)
Diversos métodos de ensaios não-destrutivos (Ultrasom, Radiografia, Termografia e Shearografia) foram empregados na inspeção de peças laminadas estruturais compósitas sólidas de matriz polimérica manufaturadas pela indústria aeronáutica. Concluiu-se que Ultrasom pulso-eco convencional de contato foi a técnica mais abrangente na indicação de descontinuidades (danos/defeitos de manufatura) considerando-se peças planas e curvas, não obstante tenha falhado na detecção de trincas longas e bem definidas localizada na alma de componentes co-curados. Radiografia convencional por filmes exibiu um potencial interessante como método alternativo, ou complementar ao de Ultrasom. Termografia infravermelha foi a técnica mais veloz na indicação de descontinuidades, sendo uma valiosa alternativa para um mapeamento rápido em inspeções preliminares seguidas pela aplicação de técnicas complementares. Shearografia realizada com equipamento da empresa Photonita detectou inclusões em peça plana compósita, porém a interpretação dos resultados obtidos em geometrias mais complexas se mostrou duvidosa. O uso de equipamento shearográfico da empresa Dantec indicou posições em regiões curvas que podem estar associadas à presença de defeitos/danos locais, porém uma confirmação cabal desta relação não foi efetivada. Evidências visuais da profusa presença de danos/defeitos de manufatura, além da existência de detalhes construtivos nas peças compósitas mais complexas, sugerem que estas descontinuidades podem ter sensibilizado, em maior ou menor extensão, os equipamentos END, juntamente com a eventual presença de delaminações/falhas de adesão nas respectivas peças avaliadas. / Several nondestructive methods (Ultrasonics, Radiography, Thermography and Shearography) were employed for inspection of structural polymer matrix composite laminated parts manufactured by aircraft industry. Is has been concluded that conventional pulse-echo contact Ultrasonics was the most comprehensive technique to indicate discontinuities (manufacture damages/defects) in flat and curved parts, although it has failed to detect long and well-defined cracks in co-cured components. Conventional film radiography exhibited good potential as alternative or complementary method to Ultrasonics. Infrared thermography was the fastest technique to indicate discontinuities, so that it is a valuable option for rapid mapping in preliminary inspection followed by the application of complementary techniques. Sherography by means of Photonita equipment detected inclusions in flat panels, but the interpretation of results from pieces with more complex geometries was dubious. A shearographic of the Dantec device indicated positions in curved regions which might possibly be associated to the presence of damages/defects, however this relationship could not be definitively established. Visual evidences of the profuse existence of manufacture damages/defects, besides constructive details in more complex composite parts, suggest that theses discontinuities might have affected to some extent the NDT equipments, along with the eventual presence of delaminations/lack of adhesion on the respective evaluated parts.
232

Estudo para a base técnica de um sistema de gerência de pavimentos para redes regionais de aeroportos.

Marcelo de Canossa Macedo 08 June 2005 (has links)
A presente pesquisa diz respeito a um estudo sobre a base técnica que pode compor um sistema de gerência de pavimentos aeroportuário, sob tráfego de aeronaves médias e leves em redes regionais, eventualmente com aviação regular. Para subsidiar os estudos, foi reunida uma abrangente base de dados constituída por informações sobre 212 aeroportos de quatro redes: dos Estados do Rio Grande do Sul, São Paulo e Texas (EUA), além de alguns aeroportos da INFRAERO e modelos empíricos existentes. Foi dada ênfase à identificação dos defeitos que predominam nesses pavimentos, à construção de modelos para previsão de desempenho e à identificação da interferência do tráfego e do clima no desempenho dos pavimentos. Por fim, é proposta uma formulação para um sistema de gerência adequado às necessidades dessas redes, tendo sido estruturado um protótipo de sistema. Resultados de simulações e da implementação preliminar desse protótipo na rede do Estado do Rio Grande do Sul são apresentados.As análises mostraram que os modelos que relacionam o pavement condition index, PCI, e a idade são suficientes para explicar o desempenho desses pavimentos. Contudo, as curvas que representam esses modelos podem resultar em índices que variam em até 50% , em determinada idade de serviço considerando uma mesma família de pavimentos. Os modelos lineares e polinomiais ajustados aos dados indicaram que, ao contrário do que se poderia esperar, a deterioração descrita pelo índice PCI ocorre com altas taxas nas idades iniciais da vida de serviço dos pavimentos. Foi demonstrado que as variáveis tráfego e clima podem interferir na construção de alguns modelos de previsão de desempenho, contudo sem apresentar uma correlação clara. O protótipo do sistema demonstrou capacidade de apresentar os resultados almejados no sentido de mostrar uma programação de investimentos que busque garantir um padrão requerido de serventia da rede, ainda que com restrições orçamentárias.
233

Proposta de um sistema de gerência para vias férreas brasileiras / Proposal for a management system for Brazilian railways

Ildefonso, Jesner Sereni 07 February 2013 (has links)
O sistema ferroviário brasileiro é constituído por uma malha de aproximadamente 30 mil quilômetros de ferrovias, nas quais percorrem mais de 2,9 mil locomotivas e 92 mil vagões, responsáveis pelo transporte de cerca 23% da carga do país; a matriz de transportes está distorcida, uma vez que nos países desenvolvidos esse modo responde por cerca de 40% da carga transportada. A manutenção de via permanente responde por 12% a 30% do custo de operação de uma via férrea e nas ferrovias brasileiras, esse gasto ficou em torno de 300 milhões de dólares no ano de 2000, evidenciando que simples melhorias no modo como as manutenções são realizadas, implicam em grande economia para o setor. Há basicamente três tipos de manutenções passíveis de serem executadas: manutenção corretiva, manutenção preventiva e manutenção preditiva. Com o uso da gerência de vias férreas é possível determinar qual manutenção é a mais apropriada e quando se deve executá-la, de forma a utilizar os recursos financeiros disponíveis da melhor forma possível. O foco desta pesquisa está no estudo da via férrea com relação à geometria e à condição estrutural dos elementos da superestrutura e, para isso, são propostos métodos de gerência e índices de qualidade para ambos os casos. / The Brazilian railway system consists of a network of approximately 30,000 kilometers, which runs a fleet of more than 2,900 locomotives and 92,000 wagons, transporting approximately 23% of the load of the country, while in developed countries this mode accounts for about 40% of the cargo. The track maintenance accounts for 12% to 30% of the cost of operating and the cost was around $ 300 million in 2000 at railroads in Brazil, showing that simple improvements in the way maintenance are performed, imply great savings for the industry. There are basically three types of maintenance that can be performed: corrective maintenance, preventive maintenance and predictive maintenance. Using the management of railways is possible to determine which is most appropriate maintenance and when to run it in order to use the available resources in the best way possible. The main goal of this research is to study the rail with respect to geometry and structural condition of the elements of the superstructure and to this are proposed methods for management and quality indexes for both cases.
234

Avaliação da influência do cromo e molibdênio na solidificação e formação de rechupes em ferros fundidos cinzentos. / Evaluation of the influence of chromium and molibdenum in the solidification and shrinkage defects in grey cast iron.

Stuewe, Luciana 02 October 2008 (has links)
Ferros fundidos cinzentos ligados com cromo e molibdênio são utilizados em cabeçotes de motor para se obter alta resistência à tração e à fadiga (com menores seções), maior resistência à temperaturas elevadas e maior estabilidade térmica. No presente trabalho é feita uma avaliação da influência da adição dos elementos de liga cromo e molibdênio na solidificação e na formação de rechupes em ferros fundidos cinzentos, através da fundição de corpos de prova com diferentes composições químicas, variando porcentagens de cromo e molibdênio comumente utilizadas em ferros fundidos cinzentos de alta resistência. Além da composição química, foi variada a porcentagem de inoculação nas ligas, através da adição de 0,2% e 0,6% do inoculante FeSi75. A simulação de fundição, utilizando o software para simulação do processo de fundição Magmasoft, foi aplicada para desenvolver um corpo de prova com tempo de solidificação similar ao de um cabeçote de motor. Depressões foram detectadas no topo dos corpos de prova, tendo sido caracterizadas como rechupes primários; microrechupes foram detectados no centro térmico, caracterizados por rechupes secundários. O volume das depressões foi medido, através de preenchimento com água. Os microrechupes foram avaliados de forma qualitativa através do ensaio de líquidos penetrantes e análise metalográfica. A avaliação da seqüência e morfologia de solidificação das fases formadas foi realizada através de análise térmica e, posteriormente, através de análises metalográficas. As temperaturas de reação eutética estável e metaestável foram calculadas através de software de termodinâmica computacional Thermocalc. A adição dos elementos de liga Cr e Mo em menores teores não causaram diferenças significativas no volume das depressões, tão pouco na presença de microrechupes. Porém adições combinadas de 0,4%, 0,6% e 1,0% de cromo e molibdênio apresentaram um aumento significativo no volume de depressão. Os resultados de simulação apresentaram resultados e curvas de solidificação similares às obtidas na prática industrial e maior tendência para a formação de rechupes primários com adições crescentes de cromo e molibdênio. Já em relação à tendência à formação de microrechupes somente adições combinadas de 0,6% e 1,0% apresentaram efeito significativo. Maiores porcentagens de adição de inoculantes aumentaram o volume tanto de depressões quanto de microrechupes, principalmente nas ligas contendo 1,0% de cromo e molibdênio. / Grey cast iron alloyed with chromium and molydnenum are used in cylinder heads to obtain high fatigue and ultimate strength (with less wall thickness), higher strength to elevated temperatures and higher thermal stability. This research presents an evaluation of the influence of chromium and molybdenum in solidification and shrinkage defects of grey cast iron alloys. The evaluation was made varying the percentages of chromium and molybdenum commonly used in high resistance grey cast iron alloys. Also the percentage of inoculation was varied with additions of 0,2% and 0,6% of the inoculant FeSi75. The foundry simulation, applying the software to simulate the foundry process MagmasoftÒ, was used to develop a test cast that should present the same solidification time of a cylinder head. Primary shrinkage defects were detected in the top of the test parts characterized as sinks and secondary shrinkage defects were detected in the hot spots, characterized as micro shrinkage porosity. Sinks volumes were measured by water filling. The micro shrinkage porosity was evaluated by liquid penetrant examination and metallographyc analysis. The solidification sequence and morphology of the phases were evaluated by thermal and metallographyc analysis. The stable and metastable eutectic reaction temperatures were calculated by ThermocalcÒ software. The compositions with less alloy additions did not present differences in the sinks or in the micro shrinkage porosity volumes. But combinations of 0,4%, 0,6% and 1,00 % of chromium and molybdenum presented a significant increase of sinks volumes. The simulation results presented similar results of solidification and cooling curves measured in the foundry and also presented the same tendency of primary shrinkage defects increase with additions of chromium and molydenum. Combinations of 0,6% and 1,00% of chromium and molybdenum presented an increase of micro shrinkage porosity volumes. Higher inoculant additions increased the volumes of both defects, mainly in combinations of 1,00% of chromium and molybdenum.
235

Visualização de informação de depuração: uma avaliação experimental / Visualization of debugging information: an empirical assessment

Silva, Fabio Pereira da 15 December 2017 (has links)
Depuração é a tarefa de localizar e corrigir defeitos em um programa. Apesar do esforço de pesquisa em depuração, especialmente nos últimos anos, ela ainda é realizada da mesma forma desde a década de 60, quando os primeiros depuradores simbólicos foram introduzidos. Localização de defeitos baseada em cobertura (LDC) é uma técnica de depuração promissora devido ao seu baixo custo de execução. LDC identifica os elementos mais suspeitos de um programa ao classificar linhas, métodos, classes e pacotes com maior valor de suspeição. Recentemente, ferramentas de visualização têm sido propostas para representar os valores de suspeição dos elementos de um programa. Entretanto, nenhuma delas foi introduzida em ambientes industriais e a utilização de depuradores simbólicos ainda é predominante. Nesta dissertação, foi avaliada a eficácia, a eficiência e a usabilidade de duas ferramentas de depuração, chamadas CodeForest e Jaguar, em ambientes reais. Jaguar apresenta os trechos mais suspeitos de um programa em uma lista ordenada por seus valores de suspeição. A CodeForest recebe informações de classes, métodos e blocos (conjunto de instruções executadas em sequência) suspeitos para construir uma floresta de cactus tridimensional representando o programa inspecionado. Na CodeForest, as classes são representadas como cactus, os métodos como galhos e os blocos como espinhos de um galho. Em ambas as ferramentas, os elementos do programa recebem cores que variam de acordo com o seu valor de suspeição. A questão básica respondida ao término deste trabalho é se as informações da depuração quando exibidas em uma metáfora visual melhoram a eficácia, a eficiência e a usabilidade na localização de defeitos. A eficácia e a eficiência foram avaliadas, respectivamente, pela capacidade da ferramenta direcionar o desenvolvedor ao método ou linha do defeito e o tempo necessário para localizá-los. A usabilidade das ferramentas foi avaliada por meio de um questionário baseado no modelo TAM (Technology Acceptance Model). Os resultados obtidos demonstram que a Jaguar foi mais eficaz, eficiente e com maior grau de usabilidade do que a CodeForest; entretanto, o tamanho do efeito estatístico é insignificante para a eficácia e eficiência e baixo para a usabilidade / Debugging is the task of locating and fixing defects in a program. Despite the research effort in debugging, especially in recent years, this task is still carried out in the same way since the 60s when the first symbolic debuggers were introduced. Spectrum-Based Fault Localization (SFL) is a promising debugging technique due to it is relative low execution cost. SFL pinpoints the most suspicious program elements by ranking lines, methods, classes and packages with greater suspicious values. Recently, visualization techniques have been proposed to represent the suspicious values of program elements. However, none of them have been introduced at industrial settings and the use of symbolic debuggers is still prevalent. This dissertation assessed the effectiveness, efficiency and usability of two debugging tools, called and CodeForest and Jaguar, in real environments. Jaguar presents the most suspicious elements of a program in a list sorted by suspicious values. CodeForest receives lists of suspicious classes, methods and blocks (set of statements executed in sequence) to build a three-dimensional cacti forest representing the program inspected. In CodeForest, classes are represented as cacti, methods as branches and blocks as thorns of a branch. In both tools, the program elements receive colors that vary according to the suspicious values. The basic question answered at the end of this research is whether debugging information when displayed as a visual metaphor improve the effectiveness, efficiency and usability during fault localization. The effectiveness and efficiency were assessed, respectively, by the tool\'s ability to direct the developer to the faulty method or line and the time spent to locate them. The tools\' usability was evaluated using the Technology Acceptance Model (TAM). The results show that Jaguar is more effective, efficient and presented greater usability than CodeForest; however, the statistical effect size is insignificant for effectiveness and efficiency and low for usability
236

Implantação iônica de oxigênio em silício

Cima, Carlos Alberto January 2001 (has links)
Foi estudada a produção de danos cristalográficos em silício por implantação de íons de oxigênio empregando-se doses na faixa de 1 x 1016 cm-2 a 4x 1017 cm-2 , energias entre 90 keV e 240 keV e temperaturas do substrato entre 25°C e 600°C. Os efeitos destas implantações sobre a estrutura cristalina foram determinados por espectroscopia de retroespalhamento de Rutherford (RBS), microscopia eletrônica de transmissão (TEM) e difração de Raios-X de alta resolução (HRXRD). O padrão de acumulação de danos sofre uma transição em ~200°C, com o deslocamento da região de máxima danificação da profundidade correspondente à maior deposição de energia por colisões nucleares para uma profundidade próxima ao alcance médio projetado dos íons. Abaixo de 200°C, a implantação iônica produz uma camada amorfa normalmente enterrada no substrato cristalino. Acima desta temperatura, não há formação de camada amorfa, mas observa-se a existência de duas regiões bem distintas. Na primeira delas, próxima da superfície, a densidade e a acumulação de danos são extremamente baixas mesmo para doses de oxigênio relativamente altas, ao passo que na segunda, centrada em torno do alcance projetado, detecta-se a presença de uma grande concentração de defeitos de natureza intersticial. Experimentos adicionais, utilizando íons de nitrogênio, neônio e magnésio em condições similares de dose, energia e temperatura, forneceram um quadro comparativo para a implantação de íons leves em alta temperatura. A produção de danos também é afetada pelas propriedades químicas dos íons, seja pela participação destes na formação de compostos, sob a forma de precipitados na matriz cristalina, seja pela sua associação a estruturas de defeitos. Verificou-se que a deformação mecânica da rede provocada pela implantação iônica depende da temperatura do substrato, energia, dose e da espécie química do íon implantado, podendo variar de uma deformação positiva de magnitude relativamente baixa, associada à expansão da distância interplanar, até um elevado valor de deformação negativa (de contração). A descrição das técnicas experimentais e dos dados obtidos numa extensa série de experiências constituem o núcleo deste trabalho científico. Os dois últimos capítulos, contudo, são devotados à análise dos resultados experimentais e à discussão das conclusões. / The production of damage in crystalline silicon by implantation of oxygen ions at elevated temperatures has been studied employing doses in the range of 1 x 1016 cm-2 to 4x1017 cm-2 • The ion energy was varied from 90 keV to 240 keV and the substrate temperature, held constant during the implantation, comprised the range from room temperature to 600°C. The effects of the implantation on the crystalline structure were monitored using three different experimental techniques : Rutherford backscattering spectrometry (RBS), transmission electron microscopy (TEM) and high resolution x-ray diffraction (HRXRD). The damage accumulation shows a transition around 200°C, since the region of maximum damage shifts from the maximum deposited energy depth to a depth near the mean projected range of the implanted ions. Below 200°C, the ion implantation creates a buried amorphous layer in the crystalline substrate. Above this temperature threshold, no amorphous layer is formed, but there are two distinct regions in the silicon samples. In the first one, dose to the surface, the damage accumulation is very low, even at relatively high oxygen doses. The second region, located around the mean projected range depth, is caracterized by a high concentration of interstitial type defect structures. Additional experiments, using nitrogen, neon and magnesium ions with implantation conditions similar to those of oxygen ions, provided a comparative picture of damage and strain accumulation by implantation with light mass ions at elevated temperatures. The damage production is affected by the chemical properties of the ions, which can participate in a variety of processes, such as the precipitation of compounds in the crystalline matrix and the formation of defective structures. The mechanical deformation dueto the ion implantation was found to be dependent on the substrate temperature, energy, dose and chemical species of the ion. The strain calculated values may vary from a relatively low positive deformation, associated with an increase in the distance between crystalline planes, to a high value of negative deformation (of contraction). The description of the data obtained in an extensive series of experiments constitutes the core of this scientific work. The last two chapters are devoted to the analysis of the experimental results and to the presentation of some conclusions.
237

Avaliação da vida à fadiga em materiais homogêneos e juntas soldadas incluindo efeitos de fechamento de trinca. / Fatigue life evaluation of homogeneous materials and welded joints including effects of crack closure.

Sarzosa Burgos, Diego Felipe 18 April 2012 (has links)
Esta tese investiga o efeito do fechamento de trinca sobre as previsões da vida à fadiga em materiais homogêneos e juntas soldadas. É apresentada uma metodologia para a simulação numérica do fenômeno de fechamento de trinca induzido por plasticidade utilizando o método dos elementos finitos. Ensaios laboratoriais de propagação de trinca por fadiga do aço ASTM A516 Gr. 70 à temperatura ambiente foram realizados usando corpos de prova típicos da mecânica da fratura nas condições soldada e homogênea. Estes resultados foram usados para validar a metodologia numérica do cálculo da carga de abertura de trinca. Comparações entre a vida de propagação experimental e as estimativas obtidas por meio da integração da lei de propagação, incluindo o efeito do fechamento de trinca, foram feitas usando vários critérios para o cálculo da carga de abertura. As análises numéricas permitem estimar a carga de abertura de trinca analisando a evolução do campo de tensões, deformações e deslocamentos na região próxima à trinca, que está influenciada pelo contato das faces da trinca. Menores níveis de proteção da trinca devido ao fechamento foram obtidos para o corpo com heterogeneidade mecânica quando comparado ao corpo homogêneo na modelagem numérica. Durante o ensaio de propagação o corpo homogêneo apresentou taxas de propagação de trinca relativamente menores quando comparadas ao espécime soldado. A não inclusão do efeito do fechamento de trinca resulta em previsões da vida à fadiga conservadoras em aproximadamente 20% para todos os casos estudados neste trabalho. Análises tridimensionais do fenômeno de fechamento de trinca revelam que o crescimento da trinca por fadiga no estagio II parece estar controlado pelo retardo que acontece na superfície do corpo de prova. Incluído o efeito do fechamento de trinca nas previsões, as estimativas da vida à fadiga foram bastante próximas das obtidas experimentalmente, com diferenças conservadoras entre 1% e 15% dependendo do método de cálculo da carga de abertura. Os resultados apresentados mostram que vidas à fadiga mais acuradas e, ainda, conservadoras são feitas incluindo o efeito do fechamento de trinca na metodologia de cálculo da vida remanescente de componentes estruturais. / This thesis investigates the effect of crack closure on fatigue life predictions in homogeneous material and welded joints. It presents a methodology for numerical simulation of the phenomenon of plasticity-induced crack closure by using the finite element method. Experimental tests of fatigue crack propagation on ASTM A516 Gr 70 steel at room temperature were performed using typical specimens of fracture mechanics in two conditions: welded and homogeneous; these results were used to validate the numerical methodology for calculating the crack opening load. Comparisons between experimental propagation life and estimations obtained by numerical integration of propagation law, including the effect of crack closure, have been made using various criteria to calculate the opening load .The numerical analyses allow to predict the opening load by analyzing the evolution of stresses, deformations and displacements fields in the region near the crack which is growing and is influenced by the contact of the crack flanks. Lower levels of protection due to crack closure were obtained for the specimen with mechanical heterogeneity when compared to the homogeneous specimen in the numerical analyses. During the test of fatigue crack propagation the homogeneous specimen had smaller crack growth rates when compared to the welded specimen. Fatigue life predictions without including the effect of crack closure result in conservative estimations around 20% for all studied cases. Three-dimensional analysis of the phenomenon of crack closure shows that the fatigue crack growth in stage II appears to be controlled by the delay that occurs on the specimen surface. Including the effect of crack closure in life predictions, the estimates of fatigue life were quite close to those obtained experimentally, with conservative differences between 1% and 15% depending on the method of opening load calculation. The results show that the fatigue life predictions can be made more accurate and yet remain conservative when the effect of crack closure is included on the methodology for calculating the remaining life of structural components.
238

Comparação da precisão e acurácia de medidas lineares com diferentes protocolos de tomografia computadorizada por feixe cônico / Comparison of accuracy and precision of linear measurements with different cone beam computed tomographic protocols

Kim, Jun Ho 25 May 2018 (has links)
Uma das complicações mais importantes relacionadas com o tratamento de implante dentário é a peri-implantite. Devido a limitação pela sobreposição de estruturas da técnica periapical, nos casos da perda óssea peri-implantar nas faces vestibulares e linguais ou palatais necessita-se de um exame capaz de prover imagens em 3 dimensões para o correto diagnóstico, sendo as imagens de tomografia computadorizada por feixe cônico (TCFC) as mais indicadas. O objetivo deste estudo foi avaliar a acurácia, especificidade, sensibilidade, concordância inter e intraobservadores e determinar a influência dos artefatos na detecção dos defeitos ósseos peri-implantares simulados em mandíbulas humanas edêndulas secas. Foram utilizados dois aparelhos de TCFC com diferentes protocolos de aquisição: i-CAT Gendex CB-500(120kVp, 5mA) e ORTHOPANTOMOGRAPH OP300(90kVp, 6.3mA). Foram instalados 24 implantes dentários cilíndricos e executados dezesseis defeitos somente nas faces vestibulares, com os comprimentos que variaram de 0,5mm a 15mm. Somente cortes sagitais foram utilizados para avaliação qualitativa e quantitativa dos defeitos foi realizada por meio de Image J. Os resultados do teste de concordância intra e inter-observadores tanto nas avaliações qualitativas e quantitativas foram predominantemente fracos. Os valores de Área Sob a Curva (ASC) variaram de 0.51 a 0.72 no i-CAT Gendex CB-500; e no ORTHOPANTOMOGRAPH OP300 variaram de 0.54 a 0.75, demonstrando desempenho diagnóstico ligeiramente superior. Nas imagens obtidas em aparelho com 120kVp (i-CAT Gendex CB-500) foram observados maior contraste em relação ao aparelho 90kVp (ORTHOPANTOMOGRAPH® OP300); em aparelho com o menor kVp (OP300) formaram mais artefatos e estes, degradaram a qualidade das imagens e influenciaram o desempenho diagnóstico das TCFCs na detecção e nas mensurações de perda óssea peri-implantar. Os protocolos de aquisições diferentes podem influenciar no aumento ou redução da formação dos artefatos. / One of the most important complications related to dental implant treatment is periimplantitis. Due to the structures overlapping inherited to periapical technique, in cases of buccal and lingual or palatal bone loss in peri-implantitis, the 3 dimensions observation exam like cone beam computed tomography(CBCT) is most indicated. The objective of this study was to evaluate the accuracy, specificity, sensitivity, interand intra-observer agreement and to determine the influence of the artifacts in the detection of the peri-implant bone defects simulated in human dry mandibles. The two CBCT devices with different acquisition protocols were used in this study: i-CAT Gendex CB-500 (120kVp, 5mA) and ORTHOPANTOMOGRAPH OP300 (90kVp, 6.3mA). Twenty-four cylindrical dental implants were placed and 16 defects were prepared only on buccal faces, the defect lengths ranged from 0.5mm to 15mm. For qualitative and quantitative assessment, only sagittal slices were evaluated by the observers, using Image J software. The results of intra and inter-observer agreement tests in both assessments were generally poor. The AUC values ranged from 0.51 to 0.72 on the i-CAT Gendex CB-500; and in the ORTHOPANTOMOGRAPH OP300 ranged from 0.54 to 0.75, showing slightly higher diagnostic performance. Higher contrast was observed in the 120 kVp device\'s images (i-CAT Gendex CB-500) when compared with the 90 kVp device\'s image (ORTHOPANTOMOGRAPH® OP300). The low kVp device (OP300), formed more artifacts which degraded the image quality and influenced the CBCT diagnostic performance in the detection and measurement of peri-implant bone loss. Different CBCT acquisition protocols may influence increasing or reducing artefact formation.
239

Avaliação das declarações de nascido vivo como fonte de informação sobre defeitos congênitos / Evaluation of the birth certificates as source of information on birth defects

Ana Lívia Geremias 24 November 2008 (has links)
Introdução: O Sistema de Informação sobre Nascidos Vivos (SINASC) é um instrumento importante para o monitoramento de defeitos congênitos (DC) ao nascer, porém há falhas de preenchimento dessa informação e possivelmente são registrados nas Declarações de Nascido Vivo (DN) os DC mais aparentes, o que pode subestimar a prevalência dos mesmos. A linkage de bancos de dados do SINASC e do SIM (Sistema de Informação de Mortalidade) permite recuperar as informações sobre DC registrados no SIM complementando os dados e fornecendo uma estimativa mais real da prevalência dos DC. Objetivo: Estimar a prevalência de DC em uma coorte de nascidos vivos (NV) vinculando-se os bancos de dados do SIM e do SINASC. Método: Estudo descritivo para avaliar as DN como fonte de informação sobre DC. A população de estudo são os NV hospitalares do 1º semestre de 2006 de mães residentes e ocorridos no Município de São Paulo no período de 01/01/2006 a 30/06/2006 e óbitos neonatais provenientes da coorte. As diferenças entre portadores e não portadores de DC foram testadas através do risco relativo, valor de p e IC 95%. Resultados: Os defeitos congênitos mais prevalentes segundo o SINASC foram: malformações congênitas e deformidades do aparelho osteomuscular (44,7%), malformação congênita do sistema nervoso (10,0%) e anomalias cromossômicas não classificadas em outra parte (8,6%). Através da linkage, houve uma recuperação de 48 casos (80,0%) de DC do aparelho circulatório, 11 casos (73,3%) de DC do aparelho respiratório e 5 casos (62,5%) de outros DC do aparelho digestivo. O SINASC fez 55,2% das notificações de DC e o SIM notificou 44,8%, mostrando-se importante para a recuperação dos dados de DC presentes na Declaração de Óbito (DO). A taxa de prevalência para os DC da coorte segundo o SINASC foi de 75,4/10.000 NV; com os dados corrigidos pelo SIM, essa taxa passou para 86,2/10.000 NV. As variáveis idade da mãe, idade gestacional, tipo de parto, Apgar, sexo e peso ao nascer mostraram-se associadas à presença de DC (p<0,001). Não foi encontrada associação entre anos de estudo, estado marital, paridade, filhos mortos anteriores, pré-natal, tipo de gravidez, raça/cor e a presença de DC. Conclusão: A complementação dos dados pelo SIM fornece um perfil diferente da prevalência de DC do que aquele que seria registrado apenas pelo SINASC, mostrando a importância do uso conjunto das duas fontes de dados. / Introduction: Live Birth Information System (SINASC) is an important instrument to monitor birth defects (BD) at the birth, however it has fulfilling imperfections of this information and they are probably registered in the Birth Certificates (BC) the BD more apparent, what can under estimate the prevalence of the some ones. The linkage of the data of SINASC and of SIM (Mortality Information System) allows the recovery of information about BD registered in SIM complementing the data and supplying a more real estimate of the prevalence of BD. Objective: Come with the prevalence of BD in a cohort of live birth (LB) associating the data base of SIM and the SINASC. Methods: Descriptive study to evaluate BD as source of information about BD. The population of study is the LB hospital of 1° semester of 2006 of resident mothers and that had happened in São Paulo city in the period from 01/01/2006 to 06/30/2006 and neonatal deaths from the cohort. The differences of carriers and not carrying of BD had been tested through the relative risk, p value and CI 95%. Results: According to SINASC the most prevalent birth defects were: birth defects and osteomuscular system deformity (44,7%), birth defects of nervous system (10,0%) and cromossomics anomalies not classified in another part (8,6%). Through linkage, it had a recovery of 48 cases (80,0%) of BD of circulatory system, 11 cases (73,3%) of BD of respiratory system and 5 cases (62,5%) of other BD of digestive system. SINASC made 55,2% of the notifications of BD and SIM notified 44,8%, showing its importance to recovery data of BD presents in Death Certificate (DC). The tax of prevalence for the BD of cohort according to SINASC was 75,4/10.000 LB; with all the data corrected by SIM, this tax changed for 86,2/10.000 LB. The variable age of mother, pregnancy age, birth type, Apgar, sex and weight at birth are associated to the presence of BD (p<0,001). Association between the years of study, marital status, parity, previous dead children, prenatal, pregnancy type, race and the presence of BD were not found. Conclusion: Data complementing by SIM supplies a different profile of prevalence of BD from those ones that would be registered only by SINASC showing the importance of the usage of two data sources.
240

Visualização de informação de depuração: uma avaliação experimental / Visualization of debugging information: an empirical assessment

Fabio Pereira da Silva 15 December 2017 (has links)
Depuração é a tarefa de localizar e corrigir defeitos em um programa. Apesar do esforço de pesquisa em depuração, especialmente nos últimos anos, ela ainda é realizada da mesma forma desde a década de 60, quando os primeiros depuradores simbólicos foram introduzidos. Localização de defeitos baseada em cobertura (LDC) é uma técnica de depuração promissora devido ao seu baixo custo de execução. LDC identifica os elementos mais suspeitos de um programa ao classificar linhas, métodos, classes e pacotes com maior valor de suspeição. Recentemente, ferramentas de visualização têm sido propostas para representar os valores de suspeição dos elementos de um programa. Entretanto, nenhuma delas foi introduzida em ambientes industriais e a utilização de depuradores simbólicos ainda é predominante. Nesta dissertação, foi avaliada a eficácia, a eficiência e a usabilidade de duas ferramentas de depuração, chamadas CodeForest e Jaguar, em ambientes reais. Jaguar apresenta os trechos mais suspeitos de um programa em uma lista ordenada por seus valores de suspeição. A CodeForest recebe informações de classes, métodos e blocos (conjunto de instruções executadas em sequência) suspeitos para construir uma floresta de cactus tridimensional representando o programa inspecionado. Na CodeForest, as classes são representadas como cactus, os métodos como galhos e os blocos como espinhos de um galho. Em ambas as ferramentas, os elementos do programa recebem cores que variam de acordo com o seu valor de suspeição. A questão básica respondida ao término deste trabalho é se as informações da depuração quando exibidas em uma metáfora visual melhoram a eficácia, a eficiência e a usabilidade na localização de defeitos. A eficácia e a eficiência foram avaliadas, respectivamente, pela capacidade da ferramenta direcionar o desenvolvedor ao método ou linha do defeito e o tempo necessário para localizá-los. A usabilidade das ferramentas foi avaliada por meio de um questionário baseado no modelo TAM (Technology Acceptance Model). Os resultados obtidos demonstram que a Jaguar foi mais eficaz, eficiente e com maior grau de usabilidade do que a CodeForest; entretanto, o tamanho do efeito estatístico é insignificante para a eficácia e eficiência e baixo para a usabilidade / Debugging is the task of locating and fixing defects in a program. Despite the research effort in debugging, especially in recent years, this task is still carried out in the same way since the 60s when the first symbolic debuggers were introduced. Spectrum-Based Fault Localization (SFL) is a promising debugging technique due to it is relative low execution cost. SFL pinpoints the most suspicious program elements by ranking lines, methods, classes and packages with greater suspicious values. Recently, visualization techniques have been proposed to represent the suspicious values of program elements. However, none of them have been introduced at industrial settings and the use of symbolic debuggers is still prevalent. This dissertation assessed the effectiveness, efficiency and usability of two debugging tools, called and CodeForest and Jaguar, in real environments. Jaguar presents the most suspicious elements of a program in a list sorted by suspicious values. CodeForest receives lists of suspicious classes, methods and blocks (set of statements executed in sequence) to build a three-dimensional cacti forest representing the program inspected. In CodeForest, classes are represented as cacti, methods as branches and blocks as thorns of a branch. In both tools, the program elements receive colors that vary according to the suspicious values. The basic question answered at the end of this research is whether debugging information when displayed as a visual metaphor improve the effectiveness, efficiency and usability during fault localization. The effectiveness and efficiency were assessed, respectively, by the tool\'s ability to direct the developer to the faulty method or line and the time spent to locate them. The tools\' usability was evaluated using the Technology Acceptance Model (TAM). The results show that Jaguar is more effective, efficient and presented greater usability than CodeForest; however, the statistical effect size is insignificant for effectiveness and efficiency and low for usability

Page generated in 0.0419 seconds