• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 26
  • 1
  • 1
  • Tagged with
  • 73
  • 73
  • 51
  • 20
  • 18
  • 16
  • 16
  • 13
  • 12
  • 12
  • 11
  • 11
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Correlation of corrosion and surface properties of NI-CR dental casting alloys before and after porcelain-fused-to-metal firing

Roach, Michael David. January 1999 (has links)
Thesis (M.S.)--Mississippi State University. Department of Agricultural and Biological Engineering. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
42

The accuracy of two die systems to replicate a master tooth a thesis submitted in partial fulfillment ... in denture prosthodontics ... /

Czerniawski, Benjamin J. January 1986 (has links)
Thesis (M.S.)--University of Michigan, 1986.
43

Estudo da dilatometria do titânio e das expansões de presa e térmica de revestimentos fosfatados

Ferreira, Anelise Rodolfo [UNESP] 30 November 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-11-30Bitstream added on 2014-06-13T20:18:33Z : No. of bitstreams: 1 ferreira_ar_me_arafo.pdf: 853886 bytes, checksum: ac8807532f1213d7b8e8c7e98c2c8cb4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O estudo avaliou a expansão térmica dos materiais metálicos titânio c.p. (RMI Company, Ohio, EUA), Co-Cr-Mo-W (Dentaurum, Pforzhem, Alemanha) e Ni-Cr (Dentaurum, Pforzhem, Alemanha) para estimar a contração de fundição do titânio e determinou a expansão de presa e térmica dos revestimentos fosfatados Rematitan Plus (Dentaurum, Pforzhem, Alemanha), específico para titânio e Rema Exakt (Dentaurum, Pforzhiem, Alemanha) e Castorit Super C (Dentaurum, Pforzhem, Alemanha). Cada concentração de líquido especial foi variada na proporção de (100%, 75% e 50%) de água destilada, com o objetivo de determinar em que concentração de líquido e em que temperatura a somatória da expansão de presa e térmica seriam suficientes para compensar a contração estimada. Para a dilatometria dos metais padrões de cera com 14 mm de altura e 7 mm de diâmetro foram obtidos a partir de um padrão metálico, em seguida, montados em base formadora de cadinho com o conduto de alimentação e incluídos com cada revestimento na concentração de 100%. Os padrões foram incluídos e aquecidos no forno EDG (EDG - Equipamentos, São Carlos, SP). O Ti c.p. foi fundido na máquina Discovery - Plasma (EDG - Equipamentos, São Carlos, SP), e as outras ligas a fundição ocorreu em máquina de fundição centrífuga convencional. Após o polimento, os corpos de prova foram analisados e a expansão térmica foi registrada no Dilatômetro DIL 409 (Netzch) em atmosfera de ar, numa taxa de aquecimento de 10ºC/min. O Ti c.p. foi aquecido até 1550ºC, o Co-Cr-Mo-W até 1160ºC e o Ni-Cr até 1090ºC. Para a medida da expansão de presa, os revestimentos foram misturados com líquido especial e vertidos no molde de silicone (Siqmol) com cavidade de 50 mm X 10 mm X 10 mm. Uma lâmina de vidro e o apalpador (Tesa)... / This study evaluated the thermal expansion of the metallic materials titanium c.p. (RMI Company, Ohio, USA), Co-Cr-Mo-W (Dentaurum, Pforzhem, Germany) and Ni-Cr-Mo (Dentaurum, Pforzhem, Germany) to estimate the casting shrinkage of titanium and determine the setting and thermal expansion of phosphate-bonded investment materials. This investment used were Rematitan Plus (Dentaurum, Pforzhem, Germany), specific for titanium, Rema Exakt (Dentaurum, Pforzhem, Germany) and Castorit Super C (Dentaurum, Pforzhem, Germany). Each concentration of special liquid/distilled/water was varied in which ratio by 100%, 75% and 50%. This aim of this study was to determine what liquid concentration and temperature the overall expansion could be enough to compensate the casting shrinkage. For the dilatometry of the metals, wax patterns (14 mm X 7 mm) were made, attached to sprue, mounted in and mounted on crucible formers and included in 100% of special liquid. The invested patterns were heated in a burnout EDG (EDE - São Carlos - Brazil). Ti c.p. was casting in the machine Discovery - Plasma (EDG - Equipments, São Carlos, SP), and the other alloys were casting in a conventional centrifugal casting machine. After polishing, the samples were analyzed and the thermal expansion was recorded in the equipment Dilatômetro DIL 409 (Netzch) in air's atmosphere, in a rate of heating of 10ºC/min. The Ti c.p. was heated up to 1550ºC, the Co-Cr-Mo-W up to 1160ºC and Ni-Cr-Mo up to 1090ºC. For measurement of the vertical setting expansion, those investments were mixed with special liquid and invested into silicone moulds of the metal pattern (50 mm x 10 mm x 10 mm). A glass plate and dial gauge were seated on the sample, and after two hours the setting expansion was measured (Se). The distance between the ends (De)...(Complete abstract, click electronic access below)
44

Photoelastic analysis of stress distribution around external hexagon and morse taper implants in different immediate loading systems = Análise fotoelástica da distribuição de tensões ao redor de implantes hexágono externo e cone Morse em diferentes sistemas de carga imediata / Análise fotoelástica da distribuição de tensões ao redor de implantes hexágono externo e cone Morse em diferentes sistemas de carga imediata

Odo, Caroline Hanada, 1987- 22 August 2018 (has links)
Orientador: Mauro Antônio de Arruda Nóbilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T01:43:18Z (GMT). No. of bitstreams: 1 Odo_CarolineHanada_M.pdf: 1232143 bytes, checksum: 6ae3560319ddd48973319b39e8cbe764 (MD5) Previous issue date: 2013 / Resumo: Dentre diversos fatores que determinam o sucesso da osseointegração e da reabilitação protética, a biomecânica se destaca como fator fundamental. Utilizando a técnica da fotoelasticidade, o objetivo neste estudo foi avaliar as tensões geradas ao redor de implantes cone morse e hexágono externo osseointegrados após carregamento distal em diferentes técnicas de carga imediata: barra distal, fundição e solda a Laser. Três infraestruturas similares (uma para cada técnica) foram confeccionadas, sobre uma matriz metálica simulando um arco mandibular edêntulo. Cinco implantes foram dispostos de maneira a simular a distribuição clínica para protocolo inferior convencional. Análogos de mini pilares foram fixados na matriz metálica e após procedimento de transferência e obtenção de modelo em gesso especial, foram confeccionadas as infraestruturas protéticas. Estas foram utilizadas em novo procedimento de transferência e posteriormente, instaladas em modelo fotoelástico confeccionado com resina epóxi flexível (GIV, Polipox Indústria e Comércio Ltda - São Paulo - SP - Brasil). Foi realizado um carregamento pontual de 4,9N na região de primeiro molar inferior direito e, posteriormente primeiro molar inferior esquerdo. Foram avaliados cinco pontos pré-determinados ao longo do implante e as imagens foram analisadas no programa Fringes® de maneira qualitativa e quantitativa através da verificação das ordens de franjas ao redor dos implantes osseointegrados. A média dos valores foi submetida à análise de variância para dados com dois fatores de estudo, seguidos pelo teste de Tukey para comparação entre as médias. Os resultados não apresentaram diferença significativa entre as infraestruturas, porém apresentou diferença significativa entre os tipos de conexões. A partir dos resultados obtidos conclui-se que não há diferença na distribuição de tensão entre as técnicas de obtenção de infraestruturas, porém quando observados os tipos de conexão, o implante Cone Morse apresentou melhores resultados em relação à distribuição de tensão / Abstract: The objective of this study was to evaluate the stresses generated around morse taper and external hexagon osseointegrated implants after distal loading in different immediate loading techniques: distal bar, casting and laser welding. Three similar infrastructures (one for each technique) were fabricated on a metal matrix simulating an edentulous mandible arch. Five implants were arranged to simulate the clinical distribution of conventional lower protocol. Analogs of the implants were fixed in a metal matrix and a transfer procedure was made. After obtaining a special plaster model, the prosthetic infrastructures were fabricated. These were used on a new transfer procedure and subsequently installed in a photoelastic model made with flexible epoxy resin (GIV Polipox Industry and Commerce Ltd - São Paulo - SP - Brazil). A load application of 4.9N was performed at the region of lower right first molar and subsequently lower left first molar. Five predetermined points along the implant were evaluated and the images were analyzed in Fringes ® program in qualitative and quantitative way by checking the orders of the fringes around the dental implants. The mean values were statistically analyzed using a 2-Way analysis of variance and Tukey test. The results showed no significant difference between the infrastructure obtaining techniques, but significant difference was seen between the types of connection. From the results obtained it is concluded that the Morse taper implant showed better results in terms of stress distribution / Mestrado / Protese Dental / Mestra em Clínica Odontológica
45

Análise da técnica de fundição rápida segundo a adaptação cervical de infra-estrutura de liga à base de Ni-Cr e expansões de presa e térmica de quatro revestimentos / Analysis of accelerated casting technique in accordance with marginal adaptation of Ni-Cr crown and curing expansion and thermal expansion of four investments

Yamaguti, Paulo Fukashi 10 September 2007 (has links)
Estudos recentes têm demonstrado que o aprimoramento dos revestimentos odontológicos para o uso da técnica de fundição rápida pode ser considerado uma realidade no seu uso diário no laboratório de prótese. Desta forma, obtêm-se peças metálicas fundidas em menor tempo, produz-se mais em pouco tempo e, diminuem-se os custos sem perda da qualidade. Mesmo assim, ainda há incógnitas sobre como estes revestimentos se expandem. Imagina-se que para obter a melhor adaptação cervical é necessária a maior expansão total do revestimento, mas alguns estudos têm demonstrado que outros fatores podem ser determinantes para obter a melhor adaptação cervical. O objetivo deste trabalho foi averiguar a adaptação cervical de infra-estruturas metálicas à base de Ni-Cr obtidas com quatro revestimentos odontológicos para a técnica de fundição rápida e analisar as expansões de presa e térmica dos mesmos. De cada revestimento foram obtidos 10 corpos de prova. Na análise da expansão de presa e térmica utilizou-se 3 corpos de prova de cada revestimento. Para a análise estatística, utilizou-se o ANOVA e o Teste de Tukey. Estas análises demonstraram que o uso do revestimento Heat Shock resultou na melhor adaptação cervical, seguido do Flash, Bellavest SH e Micro-Fine 1700. Na expansão de presa, no período de 15 minutos após a inclusão, nenhum dos revestimentos havia completado a sua total expansão. Na expansão térmica, dentro do forno no período de 20 minutos, todos os revestimentos apresentaram a expansão completada dentro de 15 minutos. Conclui-se que todos os revestimentos têm o potencial a oferecer peças fundidas com adaptação cervical adequada e que a obtenção da mesma não depende apenas da maior expansão total, mas também do comportamento da expansão de presa e da expansão térmica. Há também indícios de que a resistência à compressão do revestimento desempenha importância considerável. / With the improvement of dental investments for accelerated casting technique, recent studies have demonstrated that the procedure can be considered safe for daily use in the dental laboratory. Thus, cast pieces can be obtained in less time, the prosthetic work as a whole can be speed up and costs are cut with no quality compromise. Even though, there are still unanswered questions on how investments expand. It is thought that to reach the best cervical adaptation the greatest investment total expansion is needed, but some studies have demonstrated that other factors can be determining. The aim of this study was to verify the cervical adaptation of nickelchromium crowns cast using four dental investments for the accelerated casting technique and to analyze the curing and thermal expansion of such investments. For each investment, ten samples were obtained. For thermal expansion analysis three samples of each investment were used. For statistical purposes ANOVA and Tukey tests were used. The use of Heat Shock yielded the best results of cervical adaptation, followed by Flash, Bellavest SH and Micro-Fine 1700. For thermal expansion, 15 minutes after investment, none of the investments had reached their complete expansion. After 20 minutes inside the oven all investments had completed their expansion. It was concluded that all investments tested are suitable to offer cast pieces with adequate cervical adaptation. Adaptation depends not only of the greatest total expansion, but also of the curing and thermal expansion. There are indications that investment compression strength plays an important role on the technique.
46

O efeito da técnica de inclusão para fundição de titânio CP na fluidez, rusogidade, camada de reação e desajuste marginal /

Pieralini, Anelise Rodolfo Ferreira. January 2009 (has links)
Resumo: Esse estudo avaliou o efeito da tecnica de inclusao de revestimentos fosfatados nafluidez, rugosidade de superficie, camada de reacao (α-case) e adaptacao marginal de copings fundidos em Ti cp. Os padroes foram incluidos de forma convencional ou pela tecnica de inclusao experimental, na qual os padroes foram cobertos comRematitan Ultra - RU previamente a inclusao. Os revestimentos fosfatados estudados foram: Rematitan Plus (RP), Rema Exakt (RE), Castorit Super C (CA) e o revestimento a base de espinelio Rematitan Ultra (RU) foi o grupo controle. Sete grupos experimentais foram constituidos: G1: RU (controle); G2: RP; G3: RP e RU; G4: RE; G5: RE e RU; G6: CA; G7: CA e RU. Para fluidez foram feitos corpos-de-prova quadrados (15 mm X 15 mm X 0.3 mm) e a area (mm2) foi medida por um sistema analisador de imagens (n=8). Para a rugosidade de superficie as medidas (Ra) foram feitas em rugosimetro Mitutoyo (Mitutoyo SJ 400, Kanagawa, Japan) em corpos-de-prova quadrados (12 mm x 12 mm x 2 mm) n =8. A camada de reacao foi analisada por dureza Vickers, micro-analise por energia dispersiva (EDX), microscopia optica e a composicao dos revestimentos. Para dureza Vickers as medidas foram feitas em corpos-de-prova cilindricos (obtidos a partir dos sprues fundidos nos copos-de-prova para o teste de fluidez) em profundidades de 25, 50, 100, 150, 200 e 300Wm da superficie para o centro, em durometro Micromet 2100 (Buehler, Lake Bluff, Illinois, EUA) n= 8. Para a micro-analise por energia dispersiva (EDX) um equipamento EDX LINK ANALYTICAL, modelo QX 2000, com microscopio eletronico LEO (Zeiss - Germany) e detector OXFORD (Oxford Instrumentos de nano-analises Halifax Alta Rotacao WycombeBucks-HP12 3SE, UK) foram feitas em tres areas da camada de reacao (25 Wm, 75Wm e 150 Wm). Para a microscopia optica, as amostras foram polidas e limpas com solucao acida de Kroll por 20 segundos e observadas em Microscopio... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect investing technique with phosphate-bonded investment on the castability, surface of roughness, reaction layer (α-case) and marginal coping fit of CP titanium. For all analysis the specimen were coated with Rematitan Ultra - RU (experimental technique), previously to the inclusion (conventional technique) and invested into the phosphate-bonded investments: Rematitan Plus (RP), Rema Exakt (RE), Castorit Super C (CA). The seven groups studied were: G1: RU (control), G2: RP; G3: RP and RU; G4: RE; G5: RE and RU; G6: CA; G7: CA and RU. For castability, square patterns (15 mm X 15 mm X 0.3 mm) were made. The castability area (mm2) was measured by an image analysis system (n=8). The surface roughness was measured (Ra) with a rugosimeter Mitutoyo (Mitutoyo SJ 400, Kanagawa, Japan) in square resin patterns (12 mm x 12 mm x 2 mm) n =8. The reaction layer was analyzed by Vicker's hardness, Energy Dispersive X-ray microanalysis (EDX), optical microscopy and the investments composition were studied by X ray diffraction (XRD). The Vicker's hardness measurements were made sprue of castability test in cross - section at depths of 25, 50, 100, 150, 200 and 300Wm from the surface to the interior, using a durometer Micromet 2100 (Buehler, Lake Bluff, Illinois, EUA) n= 8. For Energy Dispersive X-ray microanalysis (EDX) was used an equipment EDX Link Analytical, model QX 2000, with Microscopy Electronic LEO (Zeiss - Germany) with detector Oxford (Oxford Instruments-Nano Analysis Halifax Road High WycombeBucks-HP12 3SE, UK) in three areas of reaction layer (25 Wm, 75Wm e 150 Wm). For the optical microscopy the samples were polished, cleaned and acid etched with the Kroll solution for 20 seconds and observed in an optical microscope Quimis (200 X) attached to an image analyzer Leika Qwin. For the study of the investments composition, samples with... (Complete abstract click electronic access below) / Orientador: Gelson Luís Adabo / Coorientador: Ricardo Faria Ribeiro / Banca: Sicknan Soares da Rocha / Banca: Renata Crisrina Silviera Ferracioli / Banca: João Neudenir Arioli Filho / Banca: Carlos Alberto dos Santos Cruz / Doutor
47

Análise da técnica de fundição rápida segundo a adaptação cervical de infra-estrutura de liga à base de Ni-Cr e expansões de presa e térmica de quatro revestimentos / Analysis of accelerated casting technique in accordance with marginal adaptation of Ni-Cr crown and curing expansion and thermal expansion of four investments

Paulo Fukashi Yamaguti 10 September 2007 (has links)
Estudos recentes têm demonstrado que o aprimoramento dos revestimentos odontológicos para o uso da técnica de fundição rápida pode ser considerado uma realidade no seu uso diário no laboratório de prótese. Desta forma, obtêm-se peças metálicas fundidas em menor tempo, produz-se mais em pouco tempo e, diminuem-se os custos sem perda da qualidade. Mesmo assim, ainda há incógnitas sobre como estes revestimentos se expandem. Imagina-se que para obter a melhor adaptação cervical é necessária a maior expansão total do revestimento, mas alguns estudos têm demonstrado que outros fatores podem ser determinantes para obter a melhor adaptação cervical. O objetivo deste trabalho foi averiguar a adaptação cervical de infra-estruturas metálicas à base de Ni-Cr obtidas com quatro revestimentos odontológicos para a técnica de fundição rápida e analisar as expansões de presa e térmica dos mesmos. De cada revestimento foram obtidos 10 corpos de prova. Na análise da expansão de presa e térmica utilizou-se 3 corpos de prova de cada revestimento. Para a análise estatística, utilizou-se o ANOVA e o Teste de Tukey. Estas análises demonstraram que o uso do revestimento Heat Shock resultou na melhor adaptação cervical, seguido do Flash, Bellavest SH e Micro-Fine 1700. Na expansão de presa, no período de 15 minutos após a inclusão, nenhum dos revestimentos havia completado a sua total expansão. Na expansão térmica, dentro do forno no período de 20 minutos, todos os revestimentos apresentaram a expansão completada dentro de 15 minutos. Conclui-se que todos os revestimentos têm o potencial a oferecer peças fundidas com adaptação cervical adequada e que a obtenção da mesma não depende apenas da maior expansão total, mas também do comportamento da expansão de presa e da expansão térmica. Há também indícios de que a resistência à compressão do revestimento desempenha importância considerável. / With the improvement of dental investments for accelerated casting technique, recent studies have demonstrated that the procedure can be considered safe for daily use in the dental laboratory. Thus, cast pieces can be obtained in less time, the prosthetic work as a whole can be speed up and costs are cut with no quality compromise. Even though, there are still unanswered questions on how investments expand. It is thought that to reach the best cervical adaptation the greatest investment total expansion is needed, but some studies have demonstrated that other factors can be determining. The aim of this study was to verify the cervical adaptation of nickelchromium crowns cast using four dental investments for the accelerated casting technique and to analyze the curing and thermal expansion of such investments. For each investment, ten samples were obtained. For thermal expansion analysis three samples of each investment were used. For statistical purposes ANOVA and Tukey tests were used. The use of Heat Shock yielded the best results of cervical adaptation, followed by Flash, Bellavest SH and Micro-Fine 1700. For thermal expansion, 15 minutes after investment, none of the investments had reached their complete expansion. After 20 minutes inside the oven all investments had completed their expansion. It was concluded that all investments tested are suitable to offer cast pieces with adequate cervical adaptation. Adaptation depends not only of the greatest total expansion, but also of the curing and thermal expansion. There are indications that investment compression strength plays an important role on the technique.
48

Comparação da adaptação cervical de estruturas metálicas para metalo-cerâmica obtidas através de técnica de fundição rápida e convencional, utilizando três revestimentos comerciais

Yamaguti, Paulo Fukashi [UNESP] January 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2002Bitstream added on 2014-06-13T19:58:25Z : No. of bitstreams: 1 yamaguti_pf_dr_araca.pdf: 1303704 bytes, checksum: c56df7e24d39dbb84e5211b463f57dd7 (MD5) / Rotineiramente, o processo de fundição odontológica envolve um tempo de espera de até três horas, porém, os novos revestimentos permitem que este seja realizado em aproximadamente 40 minutos, inclusive com ganho de qualidade. Um destes revestimentos é aglutinado por fosfato melhorado e outro é cerâmico. Pelo fato de não encontrarmos dados comparativos a respeito destes novos materiais, realizamos um estudo, verificando a sua eficácia frente à técnica de fundição rápida e a técnica de fundição convencional, comparando qual proporciona melhores resultados de adaptação cervical das estruturas metálicas obtidas. Utilizamos três revestimentos: Termocast (Polidental), Heat Shock (Polidental) e o Micro Fine 1700 (Talladium Inc.), que foram submetidos às duas técnicas propostas e cada grupo experimental foi composto por 5 corpos de prova. A verificação do desajuste cervical foi realizada através de um microscópio comparador digital. Cada corpo de prova foi medido em 4 pontos pré-determinados (V, L, M e D). A análise dos resultados demonstrou que a técnica de fundição rápida apresentou desempenho desfavorável, quando comparados com a técnica convencional para um mesmo revestimento, e a melhor adaptação; tanto na técnica de fundição convencional, como na rápida, foi a do revestimento cerâmico. Concluímos que a técnica de fundição rápida é viável para o revestimento cerâmico, mas é preciso obter resultados favoráveis também aos outros revestimentos, antes de se abandonar a técnica de fundição convencional. / Routinely, an up to three hours of waiting time is expected for dental casting process, however, new investments materials allow that this process may be performed in approximately forty minutes besides the improvement in the quality. One of the investments is agglutinated with improved phosphate and the other with ceramics. Due to the scarcity of comparative data regarding to these new materials, this study was performed to verify their behavior in accelerated and conventional casting techniques with the aim of finding out which material would provide better results of cervical fitting in the obtained metallic infra-structure. Three investments, Termocast (Polidental), Heat Shock (Polidental) and Micro Fine 1700 (Talladium, Inc.), were used, which were submitted to both casting techniques. Each experimental group was constituted by five specimens. The assessment of cervical fitting was performed by means of a comparator microscope. Each specimen was measured by using four pre-established points (V, L, M and D) as references. The results analysis showed that, for the same investment, accelerated casting technique presented worst fitting in comparison with the conventional technique, and best fitting, in both the conventional and accelerated techniques, was showed by ceramics investment. We conclude that the accelerated technique is viable for ceramic investment, but favorable results are needed with regard to other investments before the substitution of the conventional technique by the accelerated one.
49

"Estudo comparativo de dois métodos utilizados na fundição de titânio cp" / Comparative study of two cp Ti casting methods.

Rodrigues, Renata Cristina Silveira 29 April 2005 (has links)
Ao longo da última década, vários trabalhos têm destacado as vantagens do titânio e suas ligas e estudado a possibilidade de utilização para a confecção de estruturas metálicas de prótese parcial removível. Apesar das vantagens, o processo de fundição ainda apresenta problemas, limitando o uso do titânio. O objetivo deste estudo foi avaliar a influência de dois métodos de fundição, sobre microestrutura, microdureza, porosidade e força de retenção de grampos de PPR, fundidos em Co-Cr (controle) e titânio comercialmente puro (Ti cp). Foram utilizados os seguintes métodos: 1- arco voltaico (plasma) sob vácuo e pressão de argônio, com injeção do metal fundido por vácuo-pressão, e 2- indução sob vácuo e atmosfera de argônio, com injeção do metal fundido por centrifugação. Para análise da força de retenção foram confeccionadas estruturas metálicas com grampos circunferenciais sob retenção de 0,25; 0,50 e 0,75 mm, submetidas a ciclos de inserção/remoção simulando o uso por um período de 5 anos. Previamente ao ensaio de simulação, os corpos-de-prova foram radiografados em unidade laboratorial de raios X. Para o ensaio de microdureza Vickers e microestrutura foram confeccionados discos, com 5 mm de diâmetro e 2 mm de espessura, polidos metalograficamente. Os resultados mostraram que os métodos de fundição interferem nas características dos materiais estudados. As peças em titânio cp fundidas por plasma/vácuo-pressão apresentaram maior número de porosidades (50%) do que as fundidas por indução/centrifugação (16,66%). Para as peças fundidas em liga de Co-Cr, segundo a metodologia empregada, não foi possível observar a ocorrência de porosidades. As peças fundidas por plasma/vácuo-pressão apresentaram maior flexibilidade e as fundidas por indução/centrifugação apresentaram maior rigidez. Conseqüentemente, as forças de retenção foram, em geral, maiores para os corpos-de-prova obtidos por indução/centrifugação do que para aqueles obtidos por plasma/vácuo-pressão, com exceção da condição experimental de retenção 0,75 mm. Os corpos-de-prova fundidos por indução/centrifugação apresentaram, tanto para o Ti cp quanto para a liga de Co-Cr, maiores valores de microdureza Vickers do que os fundidos por plasma/vácuo-pressão. O Ti cp fundido pelo método de indução/centrifugação resultou em microestrutura de aspecto Widmanstätten, enquanto quando fundido pelo método de plasma/vácuo-pressão tem aspecto metalográfico tipo feather-like. Para a liga de Co-Cr, ambos os métodos resultaram em microestrutura dendrítica, mais fina para o método de plasma/vácuo-pressão. O Ti cp e a liga de Co-Cr, parecem ser afetados pela velocidade de resfriamento associada ao equipamento utilizado. Na análise química não foram detectadas alterações de composição dos materiais que indicassem contaminação resultante dos métodos de fundição utilizados. Assim, embora ainda apresentem problemas técnicos a serem resolvidos, ambos os métodos de fundição, indução/centrifugação e plasma/vácuo-pressão, permitem a obtenção de resultados satisfatórios na produção de estruturas metálicas de PPR em Ti cp. / Along the last decade, several jobs have been highlighting the advantages of titanium and titanium alloys and studied the possible utilization for removable partial dentures (RPD) metal frameworks confection. Although advantages, the cast process still presents problems, limiting the titanium use. The objective of this study was to evaluate the influence of two casting methods, on microstructure, microhardness, porosity and retention force of RPD clasps, casted in Co-Cr alloy (control) and commercially pure titanium (cp Ti). The cast methods used were: 1- voltaic arc (plasma) under vacuum and argon pressure, with molten metal injection by vacuum-pressure, and 2- induction under vacuum and argon atmosphere, with molten metal injection by centrifugation. For retention force analysis were made metal frameworks with circumferential clasps under retention of 0.25; 0.50 and 0.75 mm, submitted to insertion/removal cycles, simulating a 5 years use of a metal framework. Previously to the simulation test, the samples were radiographed in a laboratorial unit to verify the porosities occurrence. For Vickers microhardness test and microstructure analysis, disks with 5mm diameter and 2 mm thickness were made. The results showed that the casting methods interfere in the characteristics of studied materials. The cp Ti pieces casted by plasma/vacuum-pressure presents larger porosities number (50%) than that casted by induction/centrifugation (16.66%). For the pieces casted in Co-Cr alloy, according to the used methodology, wasn't possible to observe the occurrence of porosities. The pieces casted by plasma/vacuum-pressure presents larger flexibility and that casted by induction/centrifugation present larger rigidity. Consequently, the retention forces were, in general, larger for the samples obtained by induction/centrifugation than for those obtained by plasma/vacuum-pressure, except for the experimental condition with 0.75 mm retention. The samples casted by induction/centrifugation present, as for cp Ti as for Co-Cr alloy, larger Vickers microhardness values Vickers than that casted by plasma/vacuum-pressure. The cp Ti casted by induction/centrifugation method resulted in Widmanstätten microstructural aspect, while when casted by plasma/vacuum-pressure method has feather-like aspect. For Co-Cr alloy, both methods resulted in dendritic microstructure, finer for plasma/vacuum-pressure method. The cp Ti and Co-Cr alloy seem to be affected by the cooling rate associate to the used equipment. In the chemical analysis weren't detected materials composition alterations that indicate resultant contamination for the used casting methods. Thus, however still present technical problems to be solved, both casting methods, induction/centrifugation and plasma/vacuum-pressure, allow the obtainment of satisfactory results in the RPD metal frameworks production in cp Ti.
50

Linear expansion of dental stone after its final set and beyond two hours

Cid Galano, Marcos. January 2003 (has links)
Thesis (M.S.)--West Virginia University, 2003. / Title from document title page. Document formatted into pages; contains viii, 43 p. : ill. Vita. Includes abstract. Includes bibliographical references (p. 41-42).

Page generated in 0.0756 seconds