• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • 31
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 79
  • 79
  • 79
  • 26
  • 24
  • 24
  • 13
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Comparação da resistência de união de diferentes superfícies dentinárias na obtenção dos espécimes para microtração / Effect of different dentin surfaces on the microtensile bond strength values

Maria Angelica Silverio Agulhari 18 May 2015 (has links)
Com intuito de aumentar a longevidade das restaurações, diversos sistemas adesivos são disponibilizados no mercado e, com isso, muitos estudos são conduzidos, dentre eles, a resistência de união desses sistemas. A maioria dos trabalhos utiliza o teste de microtração. Este teste permite a avaliação de diferentes superfícies, gerando variedade nos resultados obtidos e dificultando a comparação de dados. Este estudo teve como objetivo comparar os valores de resistência de união para as diferentes superfícies de dentina utilizadas em testes de microtração (dentina planificada e dentina de paredes cavitárias, com túbulos dentinários dispostos predominantemente paralelos ou perpendiculares à interface adesiva). Foram utilizados 80 terceiros molares humanos, divididos aleatoriamente em 4 grupos e 2 subgrupos, de acordo com a superfície dentinária de obtenção dos espécimes e do sistema adesivo utilizado: G1 (PO) planificação da face oclusal (baixo fator C); G2 (PV) planificação da face vestibular (baixo fator C); G3 (CP) face pulpar de preparo cavitário oclusal (alto fator C); G4 (CV) face vestibular de preparo oclusal (alto fator C). Dois diferentes sistemas adesivos foram utilizados: convencional de 3 passos Adper Scotchbond Multi-Purpose (3M ESPE) e o autocondicionante de 2 passos Clearfil SE Bond (kuraray), resultando em 8 subgrupos (n=10): POSMp; POCf; PVSMp; PVCf; CPSMp; CPCf; CVSMp; CVCf. A resina composta (Filtek Z250 A3) foi inserida em dois incrementos horizontais. Após 48 horas, os dentes foram seccionados com disco diamantado para a obtenção dos palitos com área de seção transversal de ±0,8mm. Uma fatia de cada subgrupo foi separada para análise em MEV. Os espécimes foram fixados ao dispositivo de microtração tipo Bencor multi T adaptado à máquina de ensaios universal Instron. Uma força de tração com velocidade de 0,5 mm/min utilizando uma célula de carga de 500N foi aplicada. As superfícies fraturadas foram analisadas em Esteromicroscópio LeicaMZ6 para identificar e classificar o tipo de fratura. Os resultados foram submetidos ao teste ANOVA a 2 critérios e ao teste de Tukey com nível de significância de 5%, para cada tipo de adesivo. Os valores médios (MPa±dp) foram: POSMp: 44.51±9.28; PVSMp: 56.75±6.58; CPSMp: 27.88±5.71;CVSMp: 32.54±6.11; POCf: 48.34±8.09; PVCf: 52.51±10.18; CPCf: 23.06±5.93; CVCf: 31.35±4.03. Houve diferença estatisticamente significante para o tipo de preparo (p<0.01 para ambos adesivos) e para a orientação dos túbulos dentinários (p<0,001 para o Scotchbond Multipurpose e p=0.012 para o Clearfil SE Bond).. Concluiu-se, portanto, que os espécimes obtidos a partir de cavidades apresentaram redução nos valores de resistência de união e a orientação paralela dos túbulos em relação à interface adesiva aumentou os valores de resistência de união à microtação. / Microtensile test is usually used to evaluate bond strength values and can be affected by several factors resulting in a diversity of values which makes it difficult to compare data. Flat surfaces dentin are used in most studies. However, specimens from a tooth cavity preparation can be a more realistic model. The aim of this study was to compare &#x3BC;TBS values of dentin flat surfaces (low C factor) and dentin from cavity preparations (high C fator) and its relation with the direction of the dentin tubules. Eighty extracted caries-free human molars were assigned into 4 groups: OF (occlusal flat surface specimens low C factor); BF (buccal flat surface specimens low C factor); PC (pulp surface of cavity preparations specimens high C factor) and BC (buccal surface of cavity preparations specimens high C factor). Each group was divided into 2 subgroups according to the adhesive system Adper Scotchbond Multi-Purpose (3M ESPE) or Clearfil SE Bond (Kuraray), resulting in 8 groups (n=10): OFSMp; OFCf; BFSMp; BFCf; PCSMp; PCCf; BCSMp and BCCf. Two horizontal increments of Filtek Z250 resin were used to restore the teeth. After 48 hours storage, the specimens were sectioned into 0.8 mm beams with diamond disc for microtensile test and submitted to a tensile force in a Universal Testing Machine (Instron) at 0.5mm/min. One slice of each subgroup was randomly selected for MEV. Mean values (MPa±sd) were OFSMp: 44.51±9.28; BFSMp: 56.75±6.58; PCSMp: 27.88±5.71; BCSMp: 32.54±6.11; OFCf: 48.34±8.09; BFCf: 52.51±10.18; PCCf: 23.06±5.93; BCCf: 31.35±4.03. Data were statistically analyzed by two-way ANOVA and Tukeys test (p<0.05) for each adhesive. The adhesive failures were predominant in all groups. It can be concluded that the microtensile bond strength was influenced by the type of dentin surface and tubules orientation. The specimens obtained from cavity preparations showed reduced &#x3BC;TBS (p<0.01). Parallel tubules orientation showed a statistically significant increase of &#x3BC;TBS (p<0.001 for Scotchbond Multipurpose and p=0.012 for Clearfil SE Bond).
62

Avaliação in vitro da microinfiltração marginal e análise da fenda marginal cervical através da microscopia eletrônica de varredura, em restaurações de classe V de resina composta. Efeito dos sistemas adesivos e técnica de preparo cavitário

Orbegoso Flores, Victor Humberto [UNESP] 07 May 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-05-07Bitstream added on 2014-06-13T19:41:17Z : No. of bitstreams: 1 orbegosoflores_vh_dr_arafo.pdf: 838219 bytes, checksum: 839e8fda83a571e900cce3e586d69abb (MD5) / O objetivo deste trabalho foi avaliar a formação de fendas marginais cervicais através da microscopia eletrônica de varredura, assim como, a microinfiltração marginal em preparos de classe V. foram utilizadas duas técnicas de preparo: P1 utilizando fresa carbide no 245 e P2 que utilizou o jato de ar abrasivo Mach 4.0 (80psi de pressão, 27 æm de tamanho de partícula). O tamanho das cavidades foi padronizado com 1,5 mm de profundidade, 2,0 mm de altura e 3,0 mm de largura. Os materiais utilizados foram: G1 -Optibond solo Plus, G2 - Prime & BondNT e G3 - Scotchbond Multiuso Plus (grupo controle), a resina composta Point 4 utilizada para restaurar as cavidades foi padronizada para todas as restaurações. Foram utilizados 42 dentes molares hígidos divididos em 3 grupos de 14 cada, utilizando a face vestibular e lingual sendo que os preparos mostraram a margem oclusal em esmalte e a margem cervical em cemento/dentina. Após as restaurações serem confeccionadas foram armazenadas em água deionizada durante 24 horas, para posteriormente realizar os procedimentos de acabamento e polimento, a seguir os dentes foram isolados com araldite e esmalte para unha e submetidos a testes de ciclagem térmico (400 ciclos)e imediatamente imersos numa solução de nitrato de prata, durante 2 horas, removidos, lavados e colocados numa solução fotoreveladora durante 16 horas. Nessas condições os dentes foram limpos e seccionados no sentido mésio/distal obtendo duas metades as quais por sua vez foram seccionadas no sentido vestíbulo lingual dividindo as restaurações pela metade. Assim, uma metade da restauração foi avaliada através da lupa esteroscópica para observar a microinfiltração e a outra metade preparada e metalizada para ser avaliada através da microscopia eletrônica de varredura. A análise estatística aplicada aos resultados permite concluir que... . / The aim of this study was to evaluate the formation of cervical gap with SEM, and the marginal microleakage in cavities class V. There were used two techniques for the preparations: P1 using a carbide # 245 and P2 using abrasive air Mach 4.0 (80 psi of preasure, 27nm measurement of the particle). The measurements of the cavities were standardized in 1.5mm of deepness, 2,0mm of highness and 3,0mm of lengthiness. The materials used were: G1 Optibond Solo Plus, G2 Prime & Bond NT and G3 Scotchbond Multiuso Plus (control group), it was used the composite Point 4 as the restorative material for all cavities. Forty-two healthy molars, divided in three groups of 14 each one, were used. Cavities were prepared in the buccal and lingual faces, its occlusal margin was in enamel and its cervical margin was in dentin/cement. After that finishing and polishing was made. Teeth were isolated with analdite and nail varnish and thermocycled (400 times). The preparations were dyed with silver nitrate for two hours. Preparations were stored in a photo developing solution for 16 hours. After that time teeth were cleaned and cut (buccal/lingual) Half of the preparation was observed in a stereoscopic microscope and the other half in a SEM. Results: 1.Preparations with abrasive air had a bigger gap; 2.Adhesive systems do not eliminate the formation of gaps; 3.Best results were found in the group prepared with bur and the adhesive Optibond Solo Plus, with a cervical gap 0,84nm, and in the other hand Scotchbond Multiuso Plus showed marginal gaps of 6,36nm; 4.In the occlusal margin Optibond Solo Plus had more microleakage tha Scotchbond Multiuso Plus and Prime & Bond NT.; 5. In the cervical margin, Optibond Solo Plus had good behavior controlling the marginal microleakage, compared with Scotchbond Multiuso Plus and Prime & Bond that had similar leakage between... (Complete abstract, click electronic address below).
63

Efetividade de corte das pontas do sistema CVDentUS : estudo in vitro /

Lima, Luciana Monti. January 2003 (has links)
Orientador: Lourdes Aparecida Martins dos Santos-Pinto / Banca: Evaldo José Corat / Banca: Celso Luiz de Angelis Porto / Resumo: A tecnologia CVD (Chemical Vapor Deposition) aplicada à confecção de pontas odontológicas diamantadas possibilitou aderência do diamante à haste metálica suficiente para suportar o efeito do ultra-som, surgindo então uma técnica alternativa para corte de tecido dentário. O objetivo deste estudo in vitro foi avaliar a efetividade dos corte realizados com as pontas CVD cilíndrica e esférica para ultra-som (pontas CVDentUSÒ), em esmalte e dentina de dentes permanentes, variando-se o sentido de movimento (frontal e lateral). Foram utilizados 40 terceiros molares, num total de 80 preparos cavitários confeccionados por meio de um dispositivo padronizador. Os cortes foram realizados com 30 movimentos consecutivos da ponta sobre a superfície dentária, correspondendo a 27 segundos de utilização das pontas CVDentUSÒ. A profundidade e largura dos preparos cavitários foram analisadas em microscopia eletrônica de varredura e medidas por meio de uma análise cefalométrica modificada no programa Radiocef 4.0 (Radiocef Memory Ltda). A análise estatística pelo teste não paramétrico de Kruskal-Wallis ao nível de significância de 5% mostrou que as maiores médias de largura e profundidade foram observadas nos preparos de dentina, sendo a ponta esférica responsável por cavidades mais profundas e a cilíndrica por cavidades mais largas, não havendo influência dos sentidos de movimento da ponta. / Abstract: The CVD (Chemical Vapor Deposition) technology applied in dental diamond burs manufacture allowed to the diamond to have enough adherence to the metallic stem supporting the ultrasound effect. This technique is bringing back an alternative method to cut dental tissue. The aim of this in vitro study was to evaluate the cutting effectiveness of cylindrical and round CVD-coated diamond burs for ultrasound (CVDentUSÒ system), in enamel and dentine of permanent teeth, changing the movement sense (frontal and lateral). Forty third molars were used, in a total of 80 cavity preparations made using a standard device. The cuts were made with 30 consecutive movements of the bur on the dental surface, corresponding to 27 seconds of CVDentUSÒ tips use. The depth and width of the cavity preparations were analyzed by scanning electronic microscopy and the measures were made using a modified cefalometric analysis in a Radiocef 4.0 program (Radiocef Memory Ltda). The statistical analysis applying Kruskal-Wallis non-parametric test, at 5% significance level, showed that the largest width and depth averages were observed in dentine cavities, being the round bur responsible for deeper cavities and the cylindrical for wider cavities. The movement senses had no influence on cavity size. / Mestre
64

Eficiência na remoção de tecido desmineralizado com laser Er:YAG e sua influência na permeabilidade da dentina / Influence of Er:YAG laser in removing demineralized substrate and dentin permeability

Carmen Victoria Torres Toro 19 April 2011 (has links)
O objetivo deste estudo foi avaliar a influência do laser Er:YAG na remoção de dentina desmineralizada e sua permeabilidade no tecido remanescente. 30 fragmentos de dentina coronária a partir de 30 molares foram isolados com esmalte cosmético e cera, deixando uma área exposta de dentina de 9mm2. Para a obtenção das lesões de cárie os espécimes foram imersos durante 20 dias em solução desmineralizante (pH 4,6 a 37°C). Depois, os corpos de prova foram aleatoriamente divididos em 3 grupos (n=10) para a remoção da lesão: G1 - laser Er:YAG, (200 mJ/6Hz); G2 - broca; G3 - cureta. Em seguida, os espécimes foram imersos em uma solução aquosa de sulfato de Cu a 10% e em uma solução alcoólica de ácido rubiânico a 1% por 30 minutos, e mantidos em recipientes fechados com bolinha de algodão embebida com amônia por 7 dias. Posteriormente, foram seccionados, polidos, desidratados, clareados e colocados em laminas de vidro para sua analise por meio de microscópio ótico. As medidas de penetração do íon de cobre na dentina remanescente foram medidas em &mu;m. Os dados foram analisados pelo teste Kruskal-Wallis e correlação de Pearson. Pode-se observar que o laser promoveu um tecido mais permeável em comparação aos demais grupos (G1-17,6&mu;m; G2-6,6&mu;m; G3-5,5&mu;m), contudo não houve diferença estatística entre eles na capacidade de remoção do tecido desmineralizado (G1-10,6&mu;m; G2-8,4&mu;m; G3-11&mu;m). A correlação entre a dentina remanescente desmineralizada e permeabilidade dentinária, foi moderada para os metodos convencionais e alta para o laser Er:YAG. Conclui-se que o laser Er:YAG promoveu maior permeabilidade da dentina, estando correlacionada com a remoção do tecido desmineralizado. / The aim of this study was to evaluate the efficiency of Er:YAG laser in the removing of demineralized dentin and permeability of the remaining dentin. 30 dentin fragments obtained from 30 molars were isolated with enamel cosmetic and wax, leaving a dentin exposed area of 9mm², which was submitted to demineralization. For obtaining the lesions, the specimens were immersed during 20 days in a demineralized solution (pH4.6 at 37°C). The samples were randomly divided into 3 groups (n=10) for the removal of the demineralized lesion: G1- Er:YAG laser, (200mJ/6Hz); G2- bur; G3- curette. Later, the specimens were immersed in 10% aqueous solution of copper sulfate and 1% alcoholic solution of rubeanic acid for 30 minutes and it kept in closed jars with ammonium-embedded cotton pellets for 7 days. Then, they were sectioned, polished, dehydrated, cleared and mounted on glass slides for examination under optical microscopy. The percentages of copper ion infiltration in dentin were quantified in &mu;m. Data were analyzed by Kruskal-Wallis test and Pearson\'s correlation. The analyze revealed that the laser promoted more permeable tissue than other groups (G1-17.6&mu;m; G2-6.6&mu;m; G3-5.5&mu;m), but there was no statistical difference between them in terms of their capacity of removing the demineralized tissue (G1-10.6&mu;m; G2-8.4&mu;m; G3-11&mu;m). The correlation between remaining demineralized dentin and dentin permeability was moderated for the conventional methods and high for the Er:YAG laser. It can be concluded by the present study that he Er:YAG laser promoted higher dentin permeability, being correlated with the removal of the demineralized dentin.
65

Efeito de retenções adicionais na microinfiltração e formação de microfendas na margem gengival de restaurações de classe II extensas, feitas com resina composta: avaliação antes e após ciclagem mecânica / Effect of additional retention in microleakage and gap formation in gingival margin of class II resin restorations: evaluation before and after mechanical cycling

Sérgio Kiyoshi Ishikiriama 11 October 2006 (has links)
Este estudo laboratorial comparou a microinfiltração marginal e formação de microfendas em restaurações de classe II extensas, feitas com resina composta com margens situadas em dentina/cemento, utilizando diferentes tipos de retenções adicionais na caixa proximal. Cavidades padronizadas MOD extensas foram confeccionadas em 40 terceiros molares humanos, os quais foram divididos em 4 grupos de acordo com a retenção adicional confeccionada na caixa proximal: (G1) sem retenção adicional - controle; (G2) canaletas verticais nas paredes vestibular e lingual; (G3) orifícios na parede gengival e (G4) canaleta horizontal na parede gengival. Todos os grupos foram restaurados pela técnica incremental, com sistema adesivo (Prime Bond NT - Dentsply) e resina composta híbrida (QuiXfil - Dentsply). Todos os dentes restaurados foram imersos em corante com aplicação simultânea de cargas contínuas (forças variando entre 1kg e 17kg). Moldagens da margem gengival restaurada foram realizadas antes e após a ciclagem mecânica e réplicas de resina epóxica foram obtidas e analisadas em microscópio eletrônica de varredura para avaliação das microfendas marginais. Após as moldagens, todos os dentes foram seccionados para análise da microinfiltração marginal. Todas as micrografias da margem gengival e imagens dos cortes seccionados foram analisados quantitativamente no programa Image Tools (UTHSCSA). Os valores para microinfiltração foram submetidos a análise de variância e teste de Tukey (p< ou = 0,05). As extensões das fendas antes e após a ciclagem mecânica foram comparadas pelo teste \'t\'\' de Student. Também foi realizada uma análise de correlação entre a extensão das microfendas e microinfiltração marginal (teste de correlação de Pearson). Todos os grupos com retenção adicional (G2=11,59, G3=7,11 e G4=1,57) apresentaram microfendas significantemente menos extensas que o grupo controle sem retenção (G1=42,43) (p< ou = 0.05). Resultados similares foram obtidos para a análise de microinfiltração (G1= 82,84; G2=64,73; G3=45,42; G4=3,09), com diferenças significantes entre todos os grupos (p< ou = 0,05). Todos os grupos apresentaram aumento na extensão das fendas após a aplicação de cargas contínuas, com exceção do grupo da canaleta horizontal (grupo 4). Este tipo de retenção adicional apresentou os melhores resultados em ambos os parâmetros. Os resultados mostraram uma tendência a correlação entre os dois parâmetros estudados. Segundo os resultados, as retenções adicionais podem melhorar a adaptação marginal e minimizar a microinfiltração em restaurações de classe II extensas, feitas com resina composta. / This in vitro study compared marginal leakage and gap formation in resin composite class II cavities with gingival margin in cementum, using 3 different additional retention in proximal box. Standardized large MOD cavities, with gingival margins in cementum, were prepared in forty extracted human molars and divided into 4 groups according to the retention in proximal box: (G1) no retention; (G2) vertical grooves in buccal and lingual walls; (G3) pins in gingival wall; and (G4) horizontal grooves in gingival wall. All groups were restored with the incremental technique, using hybrid resin composite (QuiXfil - Dentsply) and bonding agent (Prime Bond NT - Dentsply). All restored teeth were immersed in dye with simultaneous mechanical loading (alternated loading between 1kg and 17kg). Impressions of gingival margins were made before and after mechanical loading and epoxic resin replicas were evaluated in scanning electron microscope for gap formation. After the impressions, all teeth were seccioned for microleakage evaluation. All SEM photomicrographs and seccioned teeth images were analysed with Image Tools (UTHSCSA) software for a quantitative analysis of both parameters. Microleakage data were evaluated by ANOVA and Tukey\'s test. Gap extension before and after mechanical loading were evaluated by Student\'s t test. A correlation analysis was made between gap extension and microleakage (Pearson\'s correlation test). All groups with additional retention (G2=11,59, G3=7,11 e G4=1,57) showed fewer gap formation than control group (G1=42,43) (p< or = 0.05). Similar results were found for microleakage tests (G1= 82,84; G2=64,73; G3=45,42; G4=3,09), with significant differences between all groups (p< or = 0,05). All groups presented an increase in gap extension after loading, with exception to group with gingival retention grooves (G4). This group (G4) showed the best results in both parameters (p< or = 0.05).The results showed a tendency for correlation between the parameters. According the results, additional retention may improve marginal adaptation and minimize leakage in large class II resin composite restorations.
66

Avaliação da incidência de micro trincas dentinárias após instrumentação reciprocante e rotatória /

Melo, Allana Agnes Pereira de. January 2019 (has links)
Orientador: Eduardo Galera da Silva / Banca: Claudio Hideki Kubo / Banca: Rodrigo Máximo de Araújo / Resumo: Para que o tratamento endodôntico tenha sucesso, buscam-se meios de realizar uma limpeza eficiente e modelagem adequada do canal radicular. No entanto, na prática clínica, alguns problemas podem ser encontrados durante a instrumentação, sendo um deles a formação de micro trincas e linhas de fratura, que podem evoluir após o estresse causado pelas forças oclusais e resultar em uma fratura completa da raiz. O presente estudo teve por objetivo avaliar a incidência de micro trincas dentinárias em 48 incisivos inferiores humanos extraídos, utilizando estereomicroscópio e Tomografia Computadorizada de Feixe Cônico (TCFC), após o preparo do canal radicular com o sistema ProDesign S (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brasil) em movimento rotatório e reciprocante, o sistema ProDesign R (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brasil) em movimento reciprocante e o sistema Reciproc (VDW, Munich, Germany) em movimento reciprocante. Além disso, buscouse analisar a superfície dos instrumentos quando sem uso, após o primeiro uso, e sucessivamente até o terceiro uso, através de estereomicroscópio e microscopia eletrônica de varredura. Os resultados foram submetidos à análise estatística por meio da Prova de Friedman. Houve formação de micro trincas dentinárias em todos os grupos avaliados em Estereomicroscópio após o preparo do canal radicular utilizando o sistema ProDesign S em movimento rotatório e reciprocante, o sistema ProDesign R em movimento reciprocant... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: So that the endodontic treatment is successful, means to achieve an efficient cleaning and proper modeling of root canal are sought. However, in clinical practice, some problems may be encountered during the instrumentation, one of them being the formation of micro cracks and lines of fracture, which may evolve after the stress caused by occlusal forces and result in a complete root fracture. The objective of this study is to evaluate the incidence of dentin micro cracks in 48 extracted human incisors using stereomicroscope and cone beam computed tomography (TCFC), after the root canal preparation with ProDesign S system (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil), in rotatory and reciprocating movement, ProDesign R system (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil) in reciprocating movement and Reciproc system (VDW, Munich, Germany) in reciprocating movement. In addition, it was aimed to analyze the instruments surface when without use, after first use, and successively until the third use, through a stereomicroscope and scanning electron microscopy. The results will be subjected to statistical analysis by means of the Friedman test. Dentin micro cracks were formed in all groups evaluated in a stereomicroscope after root canal preparation using the ProDesign S system in rotating and reciprocating motion, the ProDesign R system in reciprocating motion and the Reciproc system in reciprocating motion; but without statistically significant dif... (Complete abstract click electronic access below) / Mestre
67

Influência da irradiação com laser de Er:YAG na resistência ácida dos tecidos dentais / Influence of irradiation with Er:YAG laser on acid resistance of dental tissues

Sousa, Daniela Thomazatti Chimello de 07 March 2008 (has links)
A irradiação dos substratos dentais com laser de Er:YAG, utilizando parâmetros subablativos ou ablativos, gera um efeito térmico nas camadas mais superficiais dos tecidos, podendo levar a alterações morfológicas, estruturais e químicas. A resistência ácida dos tecidos dentais tem sido relacionada às alterações induzidas pela irradiação. Os objetivos do presente estudo foram: 1) Revisar criticamente as alterações induzidas pela irradiação com laser de Er:YAG, sua influência na resistência ácida dos tecidos dentais, e as variáveis de resposta empregadas nessas pesquisas; 2) Avaliar a microdureza do esmalte adjacente a preparos cavitários realizados com laser de Er:YAG, restaurados com resina composta e submetidos a um modelo intra-bucal de desafio cariogênico; 3) Analisar, por meio de microscopia de luz polarizada, as alterações no esmalte ao redor de preparos cavitários confeccionados com laser de Er:YAG e restaurados, após desafio cariogênico in situ, através de medidas quantitativas da área desmineralizada e largura da zona de inibição, e da análise qualitativa da ocorrência de trincas e de escores atribuídos à desmineralização e zona de inibição. A correlação entre os dados quantitativos e seus respectivos escores também foi avaliada. Baseado nos estudos realizados, foi possível concluir que a revisão crítica das alterações induzidas pelo laser de Er:YAG e dos resultados relacionados à resistência ácida dos tecidos dentais permitiu melhor entendimento da real influência da irradiação na perda mineral dos substratos. As variáveis de resposta utilizadas refletem o estágio atual das pesquisas. De modo geral, a análise do esmalte adjacente a restaurações submetidas a desafio carigênico in situ mostrou que a técnica de preparo cavitário com laser de Er:YAG foi semelhante àquela com turbina de alta-rotação, com relação à microdureza e às alterações analisadas em microscopia de luz polarizada. Os escores relacionados à zona de inibição sugeriram menor desmineralização nas margens das cavidades preparadas com laser. A correlação entre os dados quantitativos e qualitativos sugeriu que a análise por escores pode ser considerada uma alternativa viável às variáveis de resposta quantitativas, para análise de lesões de cárie ao redor de restaurações, através de microscopia de luz polarizada. / The irradiation of dental substrates with Er:YAG laser, using sub-ablative or ablative parameters, generates a thermal effect in the most superficial layers, which might lead to morphological, structural and chemical changes. Acid resistance of dental tissues has been related to the laser-induced alterations. The aims of the present study were: 1) Critically review the Er:YAG laser-induced changes, their influence on tooth acid resistance, and the response variables used in these researches; 2) Assess the microhardness of enamel adjacent to Er:YAG laser-prepared cavities, which was filled with composite resin and submitted to an intra-oral model of cariogenic challenge; 3) Analyze, by means of polarized light microscopy, the alterations in enamel around restored Er:YAG laser-prepared cavities, after cariogenic challenge in situ, by the quantitative measurement of demineralized area and inhibition zone width, and the qualitative analysis of cracks occurrence and scores attributed to demineralization and inhibition zone. The correlation between the quantitative data and their respective scores was also evaluated. Based on the conducted studies, it was feasible to conclude that the critical review of the Er:YAG laser-induced alterations and the results related to tooth acid resistance allowed a better understanding of the real influence of laser irradiation on tooth mineral loss. The response variables used reflects the current stage of researches. Generally, the analysis of enamel adjacent to restorations submitted to cariogenic challenge in situ showed that cavity preparation technique with Er:YAG laser was similar to that with high-speed handpiece, with regard to microhardness, and alterations analyzed by means of polarized light microscopy. The scores related to inhibition zone suggested less demineralization at the margins of laser-prepared cavities. The correlation between the quantitative and qualitative data suggested that the analysis by scores could be considered a viable alternative to the quantitative response variables, when assessing caries lesion around restorations, by means of polarized light microscopy.
68

Influência da irradiação com laser de Er:YAG na resistência ácida dos tecidos dentais / Influence of irradiation with Er:YAG laser on acid resistance of dental tissues

Daniela Thomazatti Chimello de Sousa 07 March 2008 (has links)
A irradiação dos substratos dentais com laser de Er:YAG, utilizando parâmetros subablativos ou ablativos, gera um efeito térmico nas camadas mais superficiais dos tecidos, podendo levar a alterações morfológicas, estruturais e químicas. A resistência ácida dos tecidos dentais tem sido relacionada às alterações induzidas pela irradiação. Os objetivos do presente estudo foram: 1) Revisar criticamente as alterações induzidas pela irradiação com laser de Er:YAG, sua influência na resistência ácida dos tecidos dentais, e as variáveis de resposta empregadas nessas pesquisas; 2) Avaliar a microdureza do esmalte adjacente a preparos cavitários realizados com laser de Er:YAG, restaurados com resina composta e submetidos a um modelo intra-bucal de desafio cariogênico; 3) Analisar, por meio de microscopia de luz polarizada, as alterações no esmalte ao redor de preparos cavitários confeccionados com laser de Er:YAG e restaurados, após desafio cariogênico in situ, através de medidas quantitativas da área desmineralizada e largura da zona de inibição, e da análise qualitativa da ocorrência de trincas e de escores atribuídos à desmineralização e zona de inibição. A correlação entre os dados quantitativos e seus respectivos escores também foi avaliada. Baseado nos estudos realizados, foi possível concluir que a revisão crítica das alterações induzidas pelo laser de Er:YAG e dos resultados relacionados à resistência ácida dos tecidos dentais permitiu melhor entendimento da real influência da irradiação na perda mineral dos substratos. As variáveis de resposta utilizadas refletem o estágio atual das pesquisas. De modo geral, a análise do esmalte adjacente a restaurações submetidas a desafio carigênico in situ mostrou que a técnica de preparo cavitário com laser de Er:YAG foi semelhante àquela com turbina de alta-rotação, com relação à microdureza e às alterações analisadas em microscopia de luz polarizada. Os escores relacionados à zona de inibição sugeriram menor desmineralização nas margens das cavidades preparadas com laser. A correlação entre os dados quantitativos e qualitativos sugeriu que a análise por escores pode ser considerada uma alternativa viável às variáveis de resposta quantitativas, para análise de lesões de cárie ao redor de restaurações, através de microscopia de luz polarizada. / The irradiation of dental substrates with Er:YAG laser, using sub-ablative or ablative parameters, generates a thermal effect in the most superficial layers, which might lead to morphological, structural and chemical changes. Acid resistance of dental tissues has been related to the laser-induced alterations. The aims of the present study were: 1) Critically review the Er:YAG laser-induced changes, their influence on tooth acid resistance, and the response variables used in these researches; 2) Assess the microhardness of enamel adjacent to Er:YAG laser-prepared cavities, which was filled with composite resin and submitted to an intra-oral model of cariogenic challenge; 3) Analyze, by means of polarized light microscopy, the alterations in enamel around restored Er:YAG laser-prepared cavities, after cariogenic challenge in situ, by the quantitative measurement of demineralized area and inhibition zone width, and the qualitative analysis of cracks occurrence and scores attributed to demineralization and inhibition zone. The correlation between the quantitative data and their respective scores was also evaluated. Based on the conducted studies, it was feasible to conclude that the critical review of the Er:YAG laser-induced alterations and the results related to tooth acid resistance allowed a better understanding of the real influence of laser irradiation on tooth mineral loss. The response variables used reflects the current stage of researches. Generally, the analysis of enamel adjacent to restorations submitted to cariogenic challenge in situ showed that cavity preparation technique with Er:YAG laser was similar to that with high-speed handpiece, with regard to microhardness, and alterations analyzed by means of polarized light microscopy. The scores related to inhibition zone suggested less demineralization at the margins of laser-prepared cavities. The correlation between the quantitative and qualitative data suggested that the analysis by scores could be considered a viable alternative to the quantitative response variables, when assessing caries lesion around restorations, by means of polarized light microscopy.
69

Efeito da base de cimento de ionômero de vidro modificado por resina e técnicas de inserção de resina composta na interface dentina/restauração adesiva / Effect of resin-modified-glass-ionomer linning and composite placement on adhesive interface

Azevedo, Larissa Marinho 06 May 2011 (has links)
Este estudo teve como objetivo avaliar o efeito da base de cimento de ionômero de vidro modificado por resina (CIVMR) e das técnicas de inserção incremental de resina composta na interface de parede circundante de restauração adesiva à dentina. Foram confeccionadas cavidades com 4,5mm X 3mm X 5mm em 52 molares humanos extraídos divididos em 4 grupos: Grupo 1 (controle): Sistema Adesivo (Adper Single Bond) + Resina Composta (Filtek Z250) com inserção em 2 incrementos horizontais (Fator C = 5); Grupo 2: Sistema Adesivo (Adper Single Bond) + Resina Composta (Filtek Z250) em 4 incrementos oblíquos (Fator C=2); Grupo 3: Base de CIVMR (Vitrebond) + Sistema Adesivo (Adper Single Bond) + Resina Composta (Filtek Z250) em 2 incrementos horizontais (Fator C = 5) e Grupo 4: Base de CIVMR (Vitrebond) + Sistema Adesivo (Adper Single Bond) + Resina Composta (Filtek Z250) em 4 incrementos oblíquos (Fator C = 2). Após a restauração, os dentes permaneceram em água deionizada em estufa a 37ºC por 24 horas. Depois foram seccionados em uma máquina de cortes com disco de diamante em espessura de 0,8mm no sentido vestíbulolingual. Uma fatia de cada dente foi separada aleatoriamente para análise em Microscópio Confocal para verificação e mensuração de fendas internas na interface dentina/resina composta. As demais fatias foram seccionadas para a confecção de palitos (0,8mm X 0,8mm) que foram submetidos a testes de microtração em uma máquina de ensaios universal EMIC. Os resultados de resistência de união foram submetidos à análise de variância a dois critério ANOVA a 5% e ao teste de Fisher para as variáveis de presença de fendas internas. Não houve diferença estatisticamente significante entre os quatro grupos (p>0,05) com relação à resistência adesiva. Quanto à presença de fendas internas, foi evidenciada sua presença nos grupos 1, 3 e 4, sem diferença estatisticamente significante entre os grupos testados (p>0,05). Conclui-se, portanto, que o uso da base de cimento de ionômero de vidro modificado por resina e das técnicas de inserção incremental de resina composta não influenciam a resistência adesiva e presença de fendas da resina composta à dentina. / The aim of this study was to evaluate the effect of resin-modified-glassionomer linning and incremental technique on the bond strength of the composite restoration interface. Methods: Cavities were made (4.5mm X 3mm X 5mm) in 52 extracted human molars, divided into 4 groups: Group 1 (control) no linning + two horizontal increments (C Factor = 5); Group 2: no linning + four oblique increments (C Factor = 2); Group 3: RMGIC linning (Vitrebond) + two horizontal increments; and Group 4: RMGIC linning (Vitrebond) + four oblique increments. All teeth were restored with Adper Single Bond and Filtek Z250 and stored in deionized water at 37ºC for 24 hours before sectioned into 0.8 mm sticks (bucco-lingually). One slice of each tooth was randomly selected for confocal microscopy for analysis of the interface resin/dentin. The other slices were sectionated in sticks (mesio-distally) for microtensile test in a Universal Testing Machine (EMIC) at 0.5mm/min. The data were analyzed by Two-way ANOVA (5%) and Fishers test for variables of presence of gap. No statistical difference on adhesive strength among groups (G1 14.55 ± 4.228 MPa, G2 17.25 ± 7.31 MPa, G3 12.81 ± 4.97 MPa and G4 13.39 ± 4.115 MPa). No significant statistical difference was observed regarding the presence of gap at the interface dentin/resin among groups (p>0.05). It can be concluded, that resin-modified glass-ionomer cement linning and resin composite techniques showed no effect on the adhesive interface to dentin.
70

Avaliação da ponta de diamante CVC (Chemical Vapor Deposition) associada ao aparelho de ultra-som

Lima, Luciana Monti [UNESP] 25 April 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-04-25Bitstream added on 2014-06-13T20:44:35Z : No. of bitstreams: 1 lima_lm_dr_arafo.pdf: 12608826 bytes, checksum: 6a6a6f942941a1dbbddbe92d7ac3a87e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentre os instrumentos de corte alternativos aos rotatórios de baixa e alta rotação que foram introduzidos na Odontologia, o uso do ultra-som associado à ponta de diamante CVD (Chemical Vapor Deposition) vem apresentando desempenho positivo, especialmente em relação à preservação da estrutura dentária e à satisfação dos pacientes. Diante de uma tecnologia ainda pouco explorada, o objetivo deste estudo foi avaliar a efetividade da ponta de diamante CVD em ultra-som, buscando evidências científicas que suportem a sua utilização no tratamento odontológico, por meio de 3 artigos seqüenciais. Estes artigos abordaram as implicações desta nova técnica de preparo cavitário na efetividade de corte de esmalte e dentina, na resistência de união por microtração e microinfiltração de restaurações de resina composta e na resposta do complexo dentino-pulpar de dentes humanos, tendo como grupo controle a ponta diamantada convencional associada à turbina de alta rotação. Os resultados evidenciaram que os preparos cavitários em esmalte e dentina confeccionados com ponta de diamante CVD em ultra-som foram mais conservadores do que os preparos com a ponta diamantada em alta rotação. As restaurações em resina composta confeccionadas após o preparo cavitário com a ponta de diamante CVD em ultrasom apresentaram valores de resistência de união significantemente maiores, no entanto, a microinfiltração nas margens em esmalte e dentina não foram diferentes entre os instrumentos de corte. Além disso, não foram observadas características de inflamação nas respostas pulpares após a utilização de ambos os instrumentos de corte, apenas uma discreta a moderada desorganização celular. / The CVD (Chemical Vapor Deposition) diamond tip coupled in ultrasound device by means of a specific connector has been an alternative to conventional diamond bur in high-speed. Besides the few scientific evidences, this new technology has been used in dental offices with good results, especially regarding the preservation of dental tissues and patient’s satisfaction. The aim of this study was to evaluate the effectiveness of the CVD diamond tip in ultrasound on dental treatment, through 3 sequential articles. These articles evaluated the implications of this new cavity preparation technique in enamel and dentin cutting effectiveness, in microtensile bond strength and microleakage of composite resin restorations, and in dentin-pulp complex response of human teeth, having the high-speed conventional diamond bur as control group. The results showed that the cavity preparations made by CVD diamond tip in enamel and dentin were more conservative than those prepared by conventional diamond bur. The resin composite restorations placed after cavity preparation with CVD diamond tip in ultrasound showed significantly higher bond strength values, however, the microleakage in enamel and dentin margins were similar for both cutting instruments. Besides, pulp response for both instruments did not show inflammatory characteristics, only a discrete or moderate cellular disorganization.

Page generated in 0.1184 seconds