• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 53
  • 13
  • 13
  • 13
  • 13
  • 12
  • 6
  • 2
  • 1
  • Tagged with
  • 140
  • 140
  • 41
  • 34
  • 34
  • 26
  • 25
  • 24
  • 22
  • 18
  • 17
  • 16
  • 15
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação do brilho, rugosidade e integridade da superfície de cerâmicas odontológicas após o polimento, abrasão por escovação e repolimento das superfícies / Evaluation of surface gloss, roughness and integrity of dental ceramics after polishing, mechanical toothbrushing and repolishing

Ursi, Wagner José Silva 02 March 2011 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T15:22:38Z (GMT). No. of bitstreams: 1 Ursi_WagnerJoseSilva_D.pdf: 1229988 bytes, checksum: 2fcbeb63eb27770fcbe7f8c7c3ecdd07 (MD5) Previous issue date: 2011 / Resumo: O objetivo neste estudo foi avaliar a influência de sistemas de polimento, da escovação mecânica e do repolimento sobre o brilho, rugosidade e morfologia da superfície de materiais cerâmicos. Três cerâmicas foram avaliadas: IPS Eris (Ivoclar Vivadent), Vita VM7 (VITA Zahnfabrik) e Cercon CS (Degudent). Trinta amostras cilíndricas padronizadas de cada material foram confeccionadas e aleatoriamente divididas em 3 grupos (n=10) sendo que cada grupo foi submetido a um dos três procedimentos de polimento (taça de borracha; disco de feltro+pasta diamantada; taça de borracha + disco de feltro + pasta diamantada). Após o polimento, o brilho da superfície polida foi mensurado com medidor de brilho (ZGM 1120 Glossmeter - Zehntner) e a rugosidade avaliada através de rugosímetro (Surfcorder SE1700 - Kosaka Lab.). As amostras foram submetidas a 30.000 ciclos mecânicos de escovação, utilizando solução de dentifrício e água deionizada. Após a escovação, as mensurações de brilho e rugosidade foram repetidas. Em seguida, as amostras foram submetidas novamente aos procedimentos de polimento, e o brilho e a rugosidade avaliados novamente. Inicialmente foi realizada análise exploratória dos dados pelo aplicativo GUIDED DATA ANALYSIS do SAS (SAS, 2008). A seguir, os dados foram analisados, segundo o conceito de medidas repetidas no tempo, empregando o procedimento PROC MIXED e teste de Tukey-Kramer. Adicionalmente, amostras polidas, escovadas e repolidas foram examinadas em microscopia eletrônica de varredura (5600LV - Jeol) para avaliação qualitativa da integridade da superfície. Com base nos resultados encontrados, pode-se concluir que a superfície dos materiais cerâmicos foi resistente aos efeitos da escovação mecânica dentro das variáveis utilizadas, e que, o uso da pasta diamantada e disco de feltro, embora tenha se mostrado eficiente na diminuição da rugosidade de superfície (Ra) para a maioria das cerâmicas avaliadas, não foi capaz de alterar os valores originais de brilho superficial. / Abstract: The purpose of this in vitro study was to evaluate the influence of polishing systems, mechanical toothbrushing and repolishing on surface gloss, roughness and morphology of dental ceramics. Three ceramic systems were evaluated: IPS Eris (Ivoclar Vivadent), Vita VM7 (VITA Zahnfabrik) and Cercon CS (Degudent). Thirty standardized cylindrical specimens of each material were fabricated and ramdomly divided in three groups (n=10), each group being submitted to one of the three polishing protocols (rubber cup; felt disc + diamond polishing paste; rubber cup + felt disc + diamond polishing paste). After polishing, surface optical gloss was determined using a gloss meter (ZGM 1120 Glossmeter - Zehntner) and surface roughness was measured with a surface profilometer ( Surfcorder SE 1700 -Kosaka Lab.). All specimens were submitted to 30,000 strokes at 2 Hz, with a dentifrice-water slurry. After mechanical toothbrushing, gloss and roughness measurements were evaluated again. Specimens were then repolished and submitted to gloss and roughness evaluations once more. Data were submitted to PROC MIXED and Tukey-Kramer tests. Aditionaly, randomly assigned specimens were evaluated for qualitative surface integrity under scanning electron microscopy (5600 LV-Jeol). Based on the results and the limitations of this in vitro study, it could be concluded that the surface of the ceramic materials tested was resistant to simulated toothbrushing challenge, and, the use of felt disc and diamond polishing paste, showed to be efficient in reducing surface roughness (Ra) for the majority of the tested ceramics, although unable to alter original surface gloss values. / Doutorado / Materiais Dentarios
112

Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p. / The influence of the veneering application and Spark erosion on the misfit level of implant-supported frameworks

Nakaoka, Marcia Mika 22 June 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:46:50Z (GMT). No. of bitstreams: 1 Nakaoka_MarciaMika_D.pdf: 1091285 bytes, checksum: 76d1bd5bef1fb0bee757a9f929be3f3a (MD5) Previous issue date: 2007 / Resumo: As distorções oriundas das técnicas de aplicação de revestimentos estéticos sobre infra-estruturas metálicas de próteses fixas podem resultar em margens cervicais desadaptadas. Dessa forma, este trabalho propôs-se a avaliar o efeito do tipo de revestimento estético, da simulação dos ciclos de cocção da cerâmica, e da aplicação da eletroerosão, sobre o desajuste de infra-estruturas implanto-suportadas fundidas em titânio comercialmente puro (Ti c.p.). Foi utilizada uma matriz metálica contendo 5 pilares intermediários do tipo Microunit. Sobre ela, foram enceradas 40 infra-estruturas, posteriormente fundidas em Ti c.p. (Tritan, Dentaurum, Alemanha). Para cada infraestrutura foi confeccionado um index, com 5 análogos parafusados em cada infra-estrutura. Esse conjunto foi posicionado em microscópio para a mensuração dos desajustes antes da aplicação dos revestimentos estéticos, com a finalidade de avaliar apenas desajuste provocado pela aplicação dos revestimentos estéticos e pelo ciclo de cocção da cerâmica. As infra-estruturas foram separadas, aleatoriamente: G1: resina acrílica ativada termicamente (Clássico, Clássico Artigos Odontológicos Ltda., São Paulo, Brasil); G2: resina fotopolimerizável (Versyo.com, Heraeus Kulzer, Brasil); G3: cerâmica (Triceram, Dentaurum J. P. Winkelstroeter KG ¿ Pforzheim - Alemanha); G4: simulação dos ciclos de cocção da cerâmica. Novamente, após a aplicação dos revestimentos estéticos, foi realizada a avaliação do desajuste marginal sobre o index. Procedeu-se o processo de eletroerosão (Tel Med Technologies, Port Huron, Michigan, EUA). As leituras de desajuste foram realizadas após o aperto com 10 Ncm em um único parafuso, correspondente ao implante A. Através desse procedimento, verificou-se a adaptação dos componentes C e E. O procedimento foi repetido com o outro implante mais distal (E), para mensuração nos implantes A e C. As leituras foram realizadas utilizando microscópio mensurador, com aumento de 120X e precisão de 0,5µm (Micro Vision ¿ Leika, Wetzlar, Alemanha), antes e após aplicação dos revestimentos estéticos, e após o processo de eletroerosão. Os resultados obtidos foram submetidos à Análise de Variância e ao teste de Tukey (p<0,05). Os valores de desajuste marginal das infra-estruturas antes da aplicação dos revestimentos estéticos não apresentaram diferença estatística significante entre si: G1: 29,81 'mu' (+ 10,66); G2: 35,30 'mu' (+ 12,15); G3: 44,75 'mu'(+ 13,73); G4: 38,57 'mu' (+ 16,94). A aplicação dos revestimentos estéticos e a simulação dos ciclos de cocção da cerâmica aumentaram significantemente os valores médios de desajuste marginal para todos os grupos: G1: 221,70 'mu' (+14,11); G2: 81,91 'mu' (+15,71); G3: 233,99 'mu' (+39,18); e G4: 119,75 'mu' (+38,08). Os grupos G1 e G3 não apresentaram diferença estatisticamente significante entre si, mas apresentaram diferença quando comparados aos G2 e G4. Após o processo de eletroerosão, apenas para o grupo G3: 161,16 µm (+36,59 ) a média de desajuste marginal apresentou-se com valor significamente menor. As médias de desajuste marginal para os grupos G1: 198,68 mu' (+34,19); G2: 62,03 'mu' (+17,73) e G4: 87,98 'mu' (+39,32) foram numericamente menores, porém, sem diferença estatística. Como ocorrido anteriormente, os grupos G1 e G3 não apresentaram diferença estatística significante, mas ambos apresentaram diferença quando comparados aos grupos G2 e G4. A partir dos resultados obtidos no presente estudo, conclui-se que os revestimentos estéticos em resina acrílica ativada termicamente e em cerâmica produziram os maiores valores de desajuste marginal para próteses implanto-retidas, enquanto a resina fotopolimerizável, os menores. A aplicação de cerâmica nas infra-estruturas produziu maiores valores de desajuste marginal quando comparado à simples simulação dos ciclos de cocção. O processo de eletroerosão mostrou-se eficaz na redução dos desajustes marginais apenas para o grupo com aplicação da cerâmica / Abstract: The demand for a passive fit of frameworks for osseointegrated endousseous implants abutments is well known, because the tightening of an inaccurate framework to the abutments can transmit stress to the bone-metal interface. The purpose of the present study was to evaluate the influence of the veneering application and porcelain firing cycle on the misfit level of implant-supported frameworks. Forty Ti c.p. (Tritan, Dentaurum, Germany) alloy frameworks were fabricated from a metallic index containing 5 Branemark type multi unit abutments. Analogs of the abutments were positioned to the framework, to construct an index for each framework. This index allowed the observation of the marginal gaps caused by the application of the veneering material. The frameworks were grouped (n=10): 1) heat acrylic resin (Clássico, Clássico, São Paulo, Brazil); 2) light polymerized resin (Versyo.com, Heraeus Kulzer, Brazil); 3) porcelain application (Triceram, Dentaurum - Germany); 4) simulation of porcelain firing cycle. Marginal refinement with spark erosion was conducted on specific equipment (Tel Med Technologies, U.S.A.). The marginal gap was obtained before and after the veneering materials and the spark erosion procedure, following the single screw test protocol (using a tightening force of 10 Ncm). A traveling microscope (STN ¿ Olympus Optical Co. Ltd Japan (120X) was used, tightening 10N in the titanium screw of the extremity distal implant, measuring the gaps at the central and distal implants. Data were subject Analysis of Variance followed by Tukey test (5%). Marginal gap mean values of the frameworks before the veneering application were not significantly different: G1: 29.81 'mu' (+ 10.66); G2: 35.30 'mu' (+ 12.15); G3: 44.75 'mu' (+13.73); G4: 38.57 'mu' (+ 16.94). The application veneering materials and the simulation of porcelain firing cycle increased significantly the misfit mean values of all groups: G1: 221.70 'mu' (+14.11); G2: 81.91 'mu' (+15.71); G3: 233.99 'mu' (+39.18); e G4: 119.75 'mu' (+38.08). There were no significant differences between G1 and G3, but they were significantly different from both G2 and G3. After the spark erosion process, marginal gap mean value decreased significantly only G3 group: 161.16 µm (+36.59). G1: 198.68 'mu' (+34.19); G2: 62.03 'mu' (+17.73) and G4: 87.98 'mu' (+39.32) groups decreased the marginal gap mean values, but not significantly after the spark erosion procedure. As occurred after the application of veneering materials, G1 and G3 groups did not show significant difference, but they both were significantly different from G2 and G4 groups. It can be concluded that heat cured acrylic resin and porcelain produced the highest mean values of marginal gaps, while light cured acrylic resin, the lowest. The application of porcelain produced higher misfit values than the simulation of porcelain firing cycles. After the spark erosion process, marginal gap mean value decreased significantly only porcelain application grou / Doutorado / Protese Dental / Mestre em Clínica Odontológica
113

Efeito do envelhecimento por ciclagem mecânica sobre a resistência à flexão de cerâmicas odontológicas / Effect of aging by mechanical cycling on the flexural strength of dental ceramics

Karen Akemi Fukushima 22 July 2011 (has links)
Os objetivos deste trabalho foram: 1) avaliar o efeito do envelhecimento por ciclagem mecânica (1 milhão de ciclos a uma freqüência de 2 Hz) sobre a resistência à flexão biaxial de três materiais cerâmicos utilizados para a construção infra-estruturas de próteses parciais fixas: a) uma zircônia tetragonal policristalina estabilizada por ítria (Y-TZP); b) uma alumina policristalina (AL) e c) um compósito de alumina e zircônia infiltrado por vidro (ICZ) e 2) determinar a influência da tensão gerada durante a ciclagem sobre a degradação da resistência das cerâmicas estudadas, já que para cada material a ciclagem foi realizada com dois níveis diferentes de tensão. Material e método: Espécimes em forma de disco (12 mm x 2 mm e 12 mm x 1 mm) foram confeccionados conforme as recomendações dos fabricantes. A resistência à flexão desses materiais foi determinada por meio do ensaio de flexão biaxial. Para o grupo controle de todos os materiais estudados (espécimes de 1 mm de espessura), foi realizada estatística de Weibull para determinação da resistência característica (0) e módulo de Weibull (m). Após o envelhecimento por ciclagem mecânica, realizado para todos os materiais nas duas espessuras, os espécimes foram fraturados e os valores obtidos foram comparados com seus respectivos grupos controle. Resultados: O valor de m foi estatisticamente semelhante para todos os materiais, o ICZ (12,2) apresentou o maior valor comparado ao do Y-TZP (9,0) e do AL (8,4). Os valores de resistência característica, 0, apresentaram diferenças significantes para todos os materiais, 828 MPa para a Y-TZP, 405,8 MPa para a AL e 328 MPa para o ICZ. Não houve diferenças estatisticamente significantes entre as resistências medidas para os grupos controle e ciclado para nenhum dos materiais nas duas espessuras avaliadas. Conclusão: O envelhecimento por ciclagem mecânica não causou alterações significativas nos valores de resistência à flexão de nenhuma das cerâmicas testadas. O aumento no nível de tensão aplicada na ciclagem mecânica não gerou um aumento na degradação da resistência dos materiais estudados. / The objectives of this study were: 1) To evaluate the effect of aging by mechanical cycling (1 million cycles at a frequency of 2 Hz) on the biaxial flexural strength of three dental ceramics used as framework materials for fixed partial dentures (FPDs): a) yttria partially stabilized zirconia tetragonal polycrystals (Y-TZP), b) alumina polycrystals (AL) and c) alumina-based zirconia-reinforced glass infiltrated ceramic (ICZ) and 2) determine the influence of stress level generated during mechanical cycling on the flexural strength degradation of the studied ceramics. Materials and Methods: Disc-shaped specimens (12 mm x 2 mm and 12 mm x 1 mm) were prepared according to manufacturer\'s recommendations. The flexural strength of these materials was determined by biaxial flexure test for the control group of all materials. The Weibull statistics was performed to determine the characteristic strength (0) and Weibull modulus (m). After mechanical aging, the specimens were fractured and the values obtained were compared with their respective control groups. Results: No statistically significant differences were founded between the strength obtained for the control and cycled groups for any of the materials in the two thicknesses tested. The m value was similar for all materials, ICZ (12.2) which showed the highest value, followed by the Y-TZP (9) and AL (8.4). The values for characteristic strength (0) showed significant differences for all materials, 828 MPa for Y-TZP, 405.8 MPa for AL and 328 MPa for ICZ. Conclusion: Aging by mechanical cycling did not cause significant changes in the values of flexural strength for all the ceramics tested. The increase in the stress level during cyclic loading did not cause an increase in the strength degradation of the materials studied.
114

Influência do tipo de sistema de infra-estrutura na adaptação e microinfiltração de coroas totais cerâmicas / Influence of the type of framework system in the adaptation and microleakage of all-ceramic crowns

Maria Tereza Moura de Oliveira Cavalcanti 04 April 2008 (has links)
Os objetivos deste trabalho foram: a quantificação da microinfiltração e desadaptação antes e após cimentação de coroas totais cerâmicas, com quatro tipos de sistemas de infra-estrutura e a correlação entre desadaptação e microinfiltração. Após aprovação pelo Comitê de Ética da FOUSP, 40 terceiros molares humanos receberam coroais totais cerâmicas, sendo: 2 cerâmicas infiltradas por vidro (In-Ceram alumina Slip-Cast (S) e o bIoco In-Ceram Alumina CA-12 (CA)) e 2 cerâmicas de alumina policristalina (Procera/Nobel Biocare (P) e o bloco In-Ceram Al-20, CEREC In-Lab (CE)), (n=10). O espaço entre coroa e dente foi medido antes e depois da cimentação das coroas. Foram submetidos à ciclagem mecânica (100.000 ciclos, 8 Kgf, 4 Hz), térmica (700 ciclos, 5/55ºC por minuto), submersos em azul de metileno 0,5% por 4 horas e seccionados nos sentidos mésio/distal e vestíbulo/lingual. As imagens foram obtidas em estereomicroscópio (20X) e os dados de desadaptação foram submetidos à ANOVA (e Tukey). Os escores da microinfiltração foram submetidos à análise da concordância dos avaliadores e Kruskal-Wallis. Não houve diferenças significantes entre os sistemas cerâmicos (S= 38, P= 49, CA= 48 e CE= 39?m). O fator \"região\" da linha de cimentação apresentou diferenças estatísticas. A desadaptação foi maior na parede pulpar (60 ?m), seguida dos ângulos axio-pulpar e gengivo-axial (57 e 48 ?m, respectivamente). As paredes axiais e margens foram os locais de menor desadaptação (27 e 26 ?m, respectivamente). Houve diferença estatística entre as duas técnicas de medida, antes e após a cimentação (46 e 41?m, respectivamente). Houve diferença estatisticamente significante entre os quatro tipos de sistemas cerâmicos avaliados quanto à microinfiltração, onde S e CE apresentaram maiores níveis de infiltração, seguidos de P e CA. Não houve correlação entre microinfiltração e desadaptação. Concluiu-se que os quatro sistemas cerâmicos avaliados produziram coroas totais com linha de cimentação dentro dos limites clinicamente aceitáveis. / The objectives of this study were to quantify the microleakage and the loss of marginal adaptation before and after cementation of all-ceramic crowns, with four types of infrastructure systems, and to compare these parameters. After approval by the Committee on Ethics in Research of Dental School of University of São Paulo, 40 human third molars received all-ceramic crowns, 2 glass-infiltrated ceramics (In-Ceram alumina Slip-Cast (S) and the block In-Ceram Alumina CA-12 (CA) ) and 2 polycrystalline alumina ceramics (Procera / Nobel Biocare (P) and the block Ceram In-Al-20, CEREC In-Lab (EC) (n = 10). The gap between ceramic dental prosthesis and tooth was measured before and after cementation of the crowns. They were subjected to mechanical load cycling (100,000 cycles, 8 Kgf, 4 Hz), thermocycling (700 cycles, 5 / 55 ° C per minute), immersed in 0.5% methylene blue dye for 4 hours and then sectioned in the mesial / distal and buccal / lingual aspects. The images were obtained in stereomicroscope (20X) and the marginal fit data were evaluated by ANOVA (and Tukey test). The microleakage values were analyzed by the correlation analysis of examiners and the Kruskal-Wallis test. There were no significant differences between the ceramic systems (S = 38, P = 49, CA = 50 and CE = 39 ? m). The factor \"region\" of the cementation line has presented statistical differences. The loss of adaptation was higher on the pulpal wall (61 ? m), followed by gingival-axial (49 ? m) and axial-pulpal (58 ? m) angles. The axial walls and margins were the sites of the smallest displacement (27 and 26 ?m, respectively). There was statistical difference between the two techniques of measurement, before and after cementation (47 and 41 ?m, respectively). Statistically significant difference among the four types of ceramic systems was detected for microleakage, whereas S and CE showed higher levels of infiltration, followed by P and CA. However, no correlation was found between microleakage and loss of marginal adaptation. It was concluded that the four systems produced all-ceramic crowns with the line of cementation within clinically acceptable limits.
115

Comportamento mecânico de cerâmicas utilizadas na confecção de próteses parciais fixas / Mechanical behavior of ceramic materials used for fixed partial dentures

Marcia Borba 23 June 2010 (has links)
Objetivos: determinar a resistência à flexão em três pontos (f), módulo de Weibull (m), coeficiente de susceptibilidade ao crescimento subcrítico de trinca (n) e tenacidade à fratura (KIC) de três cerâmicas usadas para confecção de infraestrutura (IE) de próteses parciais fixas (PPFs) (YZ- zircônia tetragonal parcialmente estabilizada por óxido de ítrio; IZ- cerâmica a base de alumina infiltrada por vidro e reforçada com zircônia; AL alumina policristalina) e duas porcelanas (VM7 e VM9); avaliar o efeito da configuração (uma, duas ou três camadas) nos valores de f e modo de fratura dos corpos-de-prova (CP); avaliar a influência do material de IE, do tamanho dos conectores e da ciclagem mecânica (CM) na carga de fratura (CF) e distribuição de tensões de PPFs; relacionar o comportamento mecânico dos materiais cerâmicos testados na configuração de barra e de PPF. Material e Método: Foram produzidos três tipos de CP em forma de barra (2mm x 4mm x 16mm): monolítico, duas camadas e três camadas. As IE das PPFs foram confeccionadas utilizando o sistema CAD-CAM e recobertas com porcelana. Os ensaios de f foram realizados em saliva artificial a 37ºC. Os valores de m e n foram determinados pela análise de Weibull e ensaio de fadiga dinâmica, respectivamente. As PPFs foram carregadas no centro do pôntico até a fratura. Oito PPFs de cada grupo foram submetidas a CM com freqüência de 2 Hz e carga de 140 N durante 106 ciclos e, posteriormente, ensaiadas até a fratura. A distribuição de tensões nas PPFs foi avaliada com análise de elementos finitos (AEF). Os princípios da fractografia foram utilizados para determinar o padrão de fratura e os valores de KIC. Os dados de f e CF foram analisados estatisticamente com Kruskal-Wallis e Tukey (95%). Resultados: A YZ obteve o maior valor de f (860 MPa) seguida dos materiais IZ (411 MPa) e AL (474 MPa) que não apresentaram diferença estatística. Os menores valores de f foram encontrados para as porcelanas (65 MPa). Os valores de m foram semelhantes para os materiais, com exceção dos grupos IZ e VM7, que apresentaram diferença significante. Os maiores valores de n foram encontrados para as cerâmicas YZ (76) e AL (72), seguidos pela IZ (54) e pelas porcelanas (40). A YZ apresentou o maior valor de KIC. O material submetido à tensão de tração durante o ensaio determinou o valor de f das estruturas. As PPFs de YZ com conector de 16mm2 suportaram os maiores valores de CF. Houve influência significativa do tamanho de conector para o material YZ. A CM não influenciou os valores de CF das PPFs. O padrão de distribuição de tensões foi semelhante entre as PPFs. Foi observada uma boa relação entre os valores de tensão de fratura dos materiais de IE em forma de barra e de PPF. Foram encontradas diferenças no modo de falha dos CP em forma de barra e de PPF. Conclusão: a YZ apresentou o melhor comportamento mecânico tanto na configuração de barra como de PPF. / Objectives: to determine the flexural strength (f), Weibull modulus (m), slow crack growth coefficient (n) and fracture toughness (KIC) of three ceramics used as framework materials for fixed partial dentures (FPDs) (YZ- yttria partially stabilized zirconia tetragonal polycrystals; IZ- alumina-based zirconia-reinforced glass infiltrated ceramic; AL alumina polycrystals) and two veneering porcelains (VM7 and VM9); to evaluate the effect of the specimen design (one, two or three layers) in the f and fracture mode; to evaluate the influence of the framework material, connector size and mechanical cycling (MC) in the fracture load (FL) and stress distribution of FPDs; to relate the mechanical behavior of the ceramic materials tested using bar-shaped specimens and FPDs. Materials and Methods: Bar-shaped specimens (2mm x 4mm x 16mm) were produced in three different designs: monolithic, bilayer and trilayer. FPD frameworks were built using CAD-CAM system and veneered with porcelain. Specimens were tested for three point bending in 37ºC artificial saliva. Weibull analysis and dynamic fatigue testing were used to determine m and n values, respectively. FPDs were tested with a load applied in the middle of the pontic. Eight FPDs of each group were subjected to MC using a frequency of 2Hz and load of 140N for 106 cycles and were subsequently loaded to failure. Stress distribution for FPDs was evaluated using finite element analysis (FEA). Fractography principles were used to determine the fracture mode and KIC values. f and FL data were analyzed using Kruskal-Wallis and Tukey (95%). Results: YZ had the highest f value (860 MPa) followed by IZ (411 MPa) and AL (474 MPa). Lower f values were observed for the porcelains (65 MPa). Except for IZ and VM7, m values were similar among the ceramic materials. Higher n values were found for YZ (76) and AL (72), followed by IZ (54) and the veneering materials (40). YZ presented the highest KIC value. The f values were influenced by the material subjected to tensile stress during testing. YZ FPDs with 16mm2 connector showed higher FL values. There was significant influence of the connector size on the FL values for YZ material. MC had no influence in the FL values for the FPDs. The stress distribution was similar for all FPDs. Considering the framework material, there was a good agreement between the fracture strength values obtained for bar-shaped specimens and FPDs. Different fracture modes were observed for bar-shaped specimens and FPDs. Conclusion: YZ presented the best mechanical performance in both bar-shaped and FPD specimen configuration.
116

Cerâmicas dentárias à base de ZrO2, aditivadas com biovidro: processamento, caracterização estrutural e mecânica / Dental ceramics to the base of ZrO2 enriched with bioglass: Processing, Structural and Mechanics Characterization

Luiz de Araujo Bicalho 06 November 2009 (has links)
Neste trabalho, foi desenvolvida e caracterizada a cerâmica à base de zircônia tetragonal aditivada com biovidro para aplicações em implantes ou próteses. Essa zircônia (Y-TZP) tem conteúdo de 3% em mol de Y2O3, com objetivo de estabilizar a fase metaestável tetragonal, a qual possui características de conferir características tenacificantes ao material. O Biovidro utilizado como aditivo de sinterização, e, supressor de interstícios foi de composição (em peso) 52,75% CaOP2O5, 30% SiO2 e 17,25% MgO.Na preparação do Biovidro os pós foram moídos, misturados e peneirados a 63 um. Misturas contendo pós de Y-TZP e Biovidros foram preparadas nas propoções (em peso) de 0, 3, 5 e 10%. As misturas destes pós foram moídas e homogeneizadas em meio úmido, utilizando moinho planetário e, em seguida, secadas, desaglomeradas e peneiradas a 63 um. Foram feitos estudos sobre o comportamento dos compactados durante a sinterização, utilizando dilatometria. As misturas foram compactadas por prensagem uniaxial à frio e submetidas à sinterização em 1300ºC, a uma taxa de aquecimento de 10ºC/min, patamar de 120 min e taxa de resfriamento de 5ºC/min. As amostras sinterizadas depois de retificadas, foram cortadas em hastes nas dimensões (mm) 3x4x45, seguindo as especificações ditadas pela norma DIN EM 843-1 (ASTM C 1161-90) e polidas. Os corpos de prova tiveram analisada a densidade relativa, identificação das fases por difração de raios X, e microestrutura por microscopia eletrônica de varredura (MEV), determinando-se o tamanho e a morfologia (razão de aspecto) média dos grãos. A dureza e a tenacidade à fratura, desses corpos sinterizados, foram avaliados utilizando método de identação Vickers. Quanto à resistência mecânica foram aplicados ensaios de flexão estática e de fadiga, utilizando dispositivo de flexão em 4 pontos. Os resultados indicaram que as amostras com maiores teores de biovidro (10%), apresentam baixa densidade relativa, enquanto as amostras com 3 e 5% possuem alta densificação, sendo indicadas para aplicações estruturais. Esses resultados são relacionados ao aumento da quantidade de fase monoclínica das amostras com 10%, o que gera microtrincamento e, consequente aumento da porosidade. Esse efeito interfere diretamente nas propriedades mecânicas, as quais indicam que amostras com 3 e 5% de biovidro possuem dureza próxima a 1150 HV, tenacidade à fratura de 6,1 a 6,3 MPam1/2, e resistência a flexão de 360 a 450 MPa. Esses resultados são superiores aos relatados a zircônica monolítica (sem adição de biovidro) e, ao material aditivado com 10% de biovidro, os quais apresentaram resultados sensivelmente inferiores da ordem de 900 HV, tenacidade máxima de 4 a 5 MPam1/2 e resistência a fratura média de 125MPa (Y-TZP) e 300MPa (Y-TZP-10% biovidro). Os resultados dos testes de fadiga indicaram que as amostras sofrem grande espalhamento de valores, os quais são inerentes das características microestruturais do material. Estas se devem principalmente ao espalhamento heterogêneo dos vidros (fase líquida) pela matriz de ZrO2 durante o processo de sinterização, promovendo regiões com diferentes quantidades de fase intergranular, o que ocasiona formação de campos com diferentes concentrações de tensão, que são, possivelmente, responsáveis pelo aparecimento das trincas e, seu respectivo crescimento subcrítico durante os testes de fadiga. Com a diminuição da tensão aplicada nos testes de fadiga, foi encontrado que o limite de resistência a fadiga destes materiais está na ordem de 220 MPa, para ambas as composições com 3 e 5% de Biovidro. / Not avaliable.
117

Degradação da resistência de cerâmicas odontológicas após ciclagem mecânica / Resistance degradation of dental ceramics after cyclic loading

Erick de Lima 23 September 2013 (has links)
Os objetivos deste trabalho foram: 1) avaliar o efeito do envelhecimento por ciclagem mecânica (3 milhões de ciclos a uma freqüência de 1 Hz) na resistência à flexão de quatro materiais cerâmicos utilizadas na confecção de próteses parciais fixas livre de metal: a) uma zircônia tetragonal policristalina estabilizada por ítria (Y-TZP); b) uma alumina policristalina (AL); c) compósito de alumina infiltrado por vidro (ICA) e d) um compósito de alumina e zircônia infiltrado por vidro (ICZ) e, 2) determinar o efeito da ciclagem mecânica no conteúdo de fase monoclínica de duas cerâmicas odontológicas contendo zircônia: a) zircônia tetragonal policristalina estabilizada por ítria e b) compósito de alumina e zircônia infiltrado por vidro. Material e método: Discos cerâmicos (12 mm x 1 mm) foram confeccionados conforme as recomendações dos fabricantes e testados em resistência à flexão biaxial. O grupo controle (sem ciclagem) de todos os materiais estudados foi submetido à estatística de Weibull para determinação da resistência característica (0) e módulo de Weibull (m). Os grupos envelhecidos mecanicamente foram fraturados em flexão biaxial e os valores obtidos foram comparados com seus respectivos grupos controle. A análise de difração de raios X (DRX) foi realizada para verificar do conteúdo de zircônia monoclínica. Resultados: Os valores médios de resistência à flexão apresentaram diferença estatisticamente significante para ambos os compósitos estudados, sendo que ICA apresentou diminuição no valor médio de resistência após a ciclagem mecânica (controle: 309,5 MPa; ciclado: 257,1 MPa) e ICZ, por outro lado, mostrou aumento da resistência após aplicação do protocolo de envelhecimento (controle: 315,6 MPa; ciclado: 359,1 MPa). As médias obtidas para materiais policristalinos foram semelhantes entre seus respectivos grupos ciclado e controle, com valores de 786,1 MPa (controle) e 841,7 MPa (ciclado) para Y-TZP e 383,5 MPa (controle) e 405,4 MPa (ciclado) para AL. Nos padrões de DRX das superfícies polidas de amostras de Y-TZP e ICZ dos grupos controle e ciclado foram observados apenas picos de difração correspondentes à fase da zircônia tetragonal. Conclusão: apenas o compósito ICA apresentou diminuição significativa nos valores de resistência à flexão após a aplicação do protocolo de ciclagem. Os outros materiais testados não sofreram degradação significativa da resistência mostrando, portanto, um melhor desempenho mecânico após uma simulação de três anos de utilização clínica. A ciclagem não causou aumento no conteúdo de zircônia monoclina nos materiais Y-TZP e ICZ / The objectives of this study were: 1) To evaluate the effect of aging by mechanical cycling (3 million cycles at a frequency of 1 Hz) on the biaxial flexural strength of four dental ceramics used as framework for the manufacture of metal free fixed partial dentures: a) yttria partially stabilized zirconia tetragonal polycrystals (Y-TZP), b) alumina polycrystals (AL), c) alumina glass infiltrated ceramic (ICA) and d) alumina-based zirconia-reinforced glass infiltrated ceramic (ICZ); and 2) to determine the effect of mechanical cycling on the monoclinic zirconia content of two dental ceramics: a) yttria partially stabilized zirconia tetragonal polycrystals (Y-TZP) and b) alumina-based zirconia-reinforced glass infiltrated ceramic. Materials and Methods: Disc-shaped specimens (12 mm x 1 mm) were prepared according to manufacturer\'s recommendations and tested in biaxial flexure strength. The control group (no cycling) of all materials studied was subjected to Weibull statistics to determine the characteristic strength (0) and Weibull modulus (m). After mechanical aging, the specimens were fractured and the values obtained were compared with their respective control groups. The X-ray diffraction (XRD) analysis was performed to analyze the monoclinic zirconia content. Results: The mean values of flexural strength showed statistically significant differences for both composites studied, being that the ICA showed a decrease in the average value of resistance after mechanical cycling (control: 309.5 MPa; cycled: 257.1 MPa) and ICZ, on the other hand, showed increase in the resistance after application of the cycling protocol (control: 315.6 MPa; cycled 359.1 MPa). The means obtained for polycrystalline materials were similar between the respective groups cycled and control, with values of 786.1 MPa (control) and 841.7 MPa (cycled) for Y-TZP and 383.5 MPa (control) and 405.4 MPa (cycled) for AL. In the XRD patterns of the polished surfaces of Y-TZP and ICZ samples both cycled and control groups were observed only diffraction peaks corresponding to the tetragonal phase of zirconia. Conclusion: Only the composite ICA showed significant decrease in flexural strength values after applying the cycling protocol. The other materials tested did not suffer significant degradation resistance showing great mechanical performance after a simulated three years of clinical use. The mechanical cycling did not cause increase in the content of monoclinic zirconia in Y-TZP and ICZ.
118

Efeito do envelhecimento por ciclagem mecânica ou ciclagem em autoclave na resistência à flexão de cerâmicas odontológicas / Mechanical and autoclave cycling effect on flexural strength of dental ceramics

Cristina Yuri Okada 29 January 2010 (has links)
Os objetivos deste trabalho foram: a) realizar a análise microestrutural de cerâmicas odontológicas e relacioná-la aos valores de resistência à flexão obtidos, b) avaliar o efeito de dois tipos de envelhecimento (ciclagem mecânica e ciclagem em autoclave) sobre a resistência à flexão desses materiais e c) avaliar se a configuração do espécime (discos versus barras) é capaz de alterar o efeito da ciclagem mecânica sobre a resistência à flexão. Cinco materiais foram utilizados: zircônia tetragonal policristalina estabilizada por ítrio (YZ), alumina policristalina (AL), alumina infiltrada por vidro/reforçada por zircônia (ICZ) e duas porcelanas (VM7 e VM9). Espécimes em forma de barra (2 x 4 x 16 mm) e disco (12 mm x 2 mm) foram confeccionados conforme as recomendações dos fabricantes. A densidade foi determinada pelo método de Arquimedes, as constantes elásticas foram determinadas pelo método do pulso-eco ultrassônico. Microscopia óptica e eletrônica de varredura foram utilizadas para determinar a fração e tamanho médio de poros e partículas e a análise de EDS para a realização de análise química dos microconstituintes. O efeito do envelhecimento por ciclagem mecânica (YZ, AL e ICZ: 80 N por 105 ciclos e VM7 e VM9: 45 N por 104 ciclos, a 2 Hz) ou por ciclagem em autoclave a 134°C, pressão de 2,2 kgf/cm2 durante 5h, foi avaliado nos espécimes em forma de barra e comparados com um grupo controle, não ciclado. O efeito do envelhecimento por ciclagem mecânica foi comparado entre os espécimes em forma de barra e disco para as porcelanas estudadas. Houve diferenças significativas entre os valores de resistência em função do material, causadas pelas diferenças em sua microestrutura, sendo que as porcelanas apresentam baixos valores de resistência (VM7: 69,4 MPa e VM9: 64,7 MPa), enquanto que a AL e a ICZ apresentaram valores intermediários (462,8 MPa e 408,6 MPa, respectivamente) e a YZ apresentou o maior valor de resistência à flexão (869 MPa). Após a ciclagem mecânica, somente o material AL apresentou redução estatisticamente significativa da resistência à flexão (389,2 MPa). A ciclagem em autoclave não resultou em degradação significativa da resistência de nenhum dos materiais testados. A configuração do espécime (barra ou disco) não alterou o efeito da ciclagem mecânica sobre a resistência das porcelanas testadas (nenhum material apresentou queda da resistência após ciclagem). Entretanto, nos espécimes em forma de disco a resistência à flexão da VM7 foi significativamente maior que a da VM9 (69,6 MPa e 57,6 MPa, respectivamente), enquanto que nos espécimes em forma de barra não houve diferença estatística entre os valores de resistência das duas porcelanas (VM7: 61,1 MPa e VM9: 68,8 MPa). / The aims of this study were: to perform a microestrutural analysis of dental ceramics and correlate the results with the flexural strength obtained; to evaluate two aging process (mechanical cycling and autoclave cycling) on the flexural strength of the materials and to evaluate the specimen configuration (bar or disc) on the flexural strength of mechanical cycling aged specimens. The five ceramics tested were: yttria-stabilized zirconia (YZ), polycrystalline alumina (AL), glass-infiltrated alumina/zirconia reinforced (ICZ) and two dental porcelains (VM7 and VM9). Bars (2 x 4 x 16 mm) and discs (12 mm x 2 mm) were produced according to the manufactures instructions. Density was obtained by Arquimedes method and the elastics constants were obtained by ultrasonic pulse-echo method. Optical and Scanning Electron Microscope were used to determine the fraction and size of both pores and particles while the chemical composition was obtained by EDS. Aging effect on flexural strength after mechanical or autoclave cycling was evaluated on bar specimens and compared to a control group, which was not cycled. The specimen configurations (bars or discs) were compared after mechanical cycling for porcelains. Microestrutural differences between material resulted on flexural strength values statistically different, porcelains presented lower values of flexural strength (VM7: 69,4 MPa and VM9: 64,7 MPa), while AL and ICZ presented intermediate flexural strength (462,8 MPa and 408,6 MPa, respectively) and YZ presented the highest flexural strength (869 MPa). Only AL presented a significant lower flexural strength after mechanical cycling (389,2 MPa). Autoclave cycling did not influence the flexural strength of the studied materials. Also, the specimen configuration did not influence the flexural strength values before or after mechanical cycling. It should be noted that disc specimens of VM7 presented significantly higher flexural strength values than VM9 (69,6 MPa and 57,6 MPa, respectively), however for bar specimens no statistical difference was noted between the mean strength of both porcelains (VM7: 61,1 MPa and VM9: 68,8 MPa).
119

Influencia do metodo de fotoativação e materiais restauradores indiretos sobre o grau de conversão e dureza Knoop de um cimento resinoso dual / The influence of light curing and indirect restorative materials on conversion degree and Knoop hardness of dual-cured resin cement

Komori, Paula Carolina de Paiva 12 September 2008 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T10:14:46Z (GMT). No. of bitstreams: 1 Komori_PaulaCarolinadePaiva_D.pdf: 603004 bytes, checksum: 11e75b4ee3e84d165caa74d684ffbe94 (MD5) Previous issue date: 2008 / Resumo: Os cimentos resinosos têm sido amplamente utilizados devido à capacidade de união ao dente e a prótese fixa e ao sucesso estético. Os cimentos resinosos apresentam ativação química, física ou dupla ativação. Para esses cimentos, quanto maior o grau de polimerização melhores serão suas propriedades. Entretanto, em diversas situações clínicas a polimerização é afetada pela distância da ponta da unidade fotoativadora em relação ao cimento, pela presença de restaurações indiretas ou estrutura dentária. Assim, este estudo avaliou a polimerização de um cimento resinoso de dupla ativação RelyX ARC (RLX), sob diferentes condições. No primeiro estudo para simular uma restauração indireta foram confeccionados discos com 1,4mm de espessura e 8mm de diâmetro das cerâmicas Empress 2 (EMP) e Empress Esthetic (EST), Duceram Plus (DUC) e resina composta Z250 (Z250). Amostras do RLX com 0,8mm de espessura e 5mm de diâmetro, foram fotoativadas diretamente e indiretamente sob o anteparo, com os aparelhos de fotoativação com lâmpada halógena (QTH - 800mW/cm2) e por diodo emissor de luz (LED - 1100mW/cm2). A potência (mW) das fontes de luz foram medidas com um potenciômetro (Ophir) e o espectro da luz emitida foi registrado com espectrômetro (USB 2000), com e sem a presença do anteparo. No segundo estudo as amostras do cimento foram fotoativadas diretamente com QTH ou LED, recebendo diferentes densidades de energia (10, 20, e 30J/cm2). O grau de polimerização do RLX foi mensurado com a porcentagem do grau de conversão pelo método FT-Raman (CD) e dureza Knoop (KHN). Os resultados obtidos CD (%) e KHN foram submetidos à Análise de Variância e teste de Tukey (5%). De acordo com os resultados destes estudos foi possível concluir que o CD e a KHN podem ser influenciadas pelo tipo de aparelho fotoativador, densidade de energia, assim como, pela presença de restaurações indiretas. / Abstract: The resin cements have been widely used because it provide link between prosthesis and tooth structure and esthetic success. Resin cements are available in chemical-cured, light-cured or dual-cured mode. For this type of cements higher polymerization reflects in improvement on properties. However in many clinical situations polymerization is affected by indirect restoration, tooth or distance of light-curing unit tip to cement. This study evaluated the polymerization of dual-cured resin cement RelyX ARC (RLX) in different simulated clinical conditions. The first study simulated indirect restoration with disks of 1.4mm in thickness and 8mm in diameter of Empress 2 (EMP), Empress Esthetic (EST), Duceram Plus (DUC) ceramics, and resin composite Z250 (Z250). Specimens of RLX with 0.8mm in thickness and 5mm in diameter were light-cured directly and indirectly through restorative materials with quartz-tungsten-halogen (QTH 800mW/cm2) or light-emitting diode (LED 1100mW/cm2). The output power energy (mW) emitted by each light-curing unit was measured with the digital power meter (Ophir) and the spectral output emitted by each unit was registered using a spectrometer (USB 2000), directly and through the disks. In the second study, RLX specimens were lightcured directly with QTH or LED with 10, 20 e 30J/cm2 energy densities. The degree of polymerization achieved by RLX was analyzed by conversion degree (CD) using a FT-Raman Spectrometer and Knoop hardness test (KHN). Data of CD (%) and Knoop hardness (KHN) were submitted to Analysis of Variance and to Tukey's test (5%). According to the results of these studies were unable to conclude that CD and KHN can be influenced by the lightcuring units, light energy density and also by the presence of indirect restorations. / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
120

Resistência ao micro-cisalhamento de cimentos resinosos fotoativados através de diferentes espessuras de cerâmica = Micro-shear bond strength of resin cements photoactivated through different ceramic thickness / Micro-shear bond strength of resin cements photoactivated through different ceramic thickness

Barrientos Nava, Juan Rene, 1972- 04 June 2015 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T14:20:39Z (GMT). No. of bitstreams: 1 BarrientosNava_JuanRene_M.pdf: 979069 bytes, checksum: 74108d8d78e414edaddbf2d5747d4ee6 (MD5) Previous issue date: 2015 / Resumo: O objetivo neste estudo foi avaliar a resistência da união ao cisalhamento de cimentos resinosos fotoativados através de diferentes espessuras de cerâmica e o modo de fratura. Foram utilizados os cimentos resinosos RelyX U200 (3M ESPE) e Variolink II (Ivoclar-Vivadent). Sessenta discos de cerâmica IPS Empress Esthetic (Ivoclar-Vivadent) com 12mm de diâmetro foram separados em grupos (n=10) segundo a espessura (0,7; 1,4 e 2,0mm). A superfície dos discos foi condicionada com ácido hidrofluorídrico a 10% por 60s, lavada e seca com jato de ar por 60s. A seguir foi feita aplicação de agente silano por 60s. Uma matriz de elastômero com forma de disco com 15mm de diâmetro e 0,5mm de espessura com quatro orifícios de 1,5mm de diâmetro foi usada para delimitar a área de adesão na cerâmica. A manipulação dos cimentos resinosos foi de acordo com as instruções dos fabricantes, o material inserido nos orifícios da matriz, recoberto com tira de poliéster e lâmina de microscópio com pressão digital. A fotoativação foi realizada através do disco de cerâmica com Ultra Lume LED 5 (Ultradent) com potência de 1200 mW/cm² por 60s. Após armazenagem por 24h em água destilada a 37ºC, os corpos-de-prova foram avaliados com lupa estereoscópica para descartar aqueles com imperfeições. O teste de resistência ao cisalhamento foi conduzido em máquina de Ensaio Universal Instron (Canton, MA, USA), com velocidade de 1 mm/min e com célula de carga de 50Kg até fratura e os valores de resistência da união calculados em MPa. O modo de fratura foi analisado com lupa estereoscópica (LABOMED, Barueri, SP), com aumento de 10 vezes. Os resultados foram submetidos à análise de variância de dois fatores e teste de Tukey (5%). Os modos de fratura foram considerados em função da predominância das falhas sendo a falha coesiva em cerâmica a que prevaleceu. Os resultados mostraram que a interação entre os fatores espessura da cerâmica e cimento, e o fator espessura não foram significantes (p=0,541 e p=0,643, respectivamente), enquanto o fator cimento foi significativo (p=0,009). Pode-se concluir que o cimento Variolink II apresentou resistência de união significantemente maior que a do cimento RelyX U200 / Abstract: The aim of this study was to evaluate the bond shear strength of resin cements photoactivated through different thicknesses of ceramics and the failure mode. RelyX U200 (3M ESPE) and Variolink II (Ivoclar Vivadent) resin cements were used. Sixty ceramic discs of Esthetic IPS Empress (Ivoclar-Vivadent) with 12mm diameter were divided into groups (n=10) according to their thickness (0.7; 1.4 and 2.0mm). The grounded surface was etched with 10% hydrofluoric acid for 60 seconds, rinsed and dried with compressed air for 60s. The following silane application was made for 60s. An elastomeric matrix having 15mm in diameter and 0.5mm in thickness with four holes (1.5mm in diameter) was used to define the adhesion area in the ceramic. The manipulation of the resin cements was carried out according to the manufacturers¿ instructions and inserted into the holes of the elastomer matrix, covered with plastic strip and finger pressed with a microscope slide. Light curing through ceramic was Ultra Lume LED 5 (Ultradent) with power 1200mW/cm² for 60s. After storage for 24h in distilled water at 37ºC, all resin cylinders were checked under magnification. The shear strength test was conducted in a Instron Universal Testing Machine, at cross-head speed of 1mm/min with load of 50Kg until fracture. The bond strength values were calculated (MPa). The fracture mode was analyzed using stereoscopic lens 10x (LABOMED, Barueri, SP). The results were submitted to two-way ANOVA and the means compared by Tukey¿s test (5%). Cohesive failure mode within ceramic was predominant. The results showed that the interaction between the factors and cement thickness, and the thickness factor were not statistically significant (p=0.541 and p=0.643, respectively). The cement factor was significant (p=0.009). In conclusion, the Variolink II showed significantly higher bond strength value than the RelyX U200 cement / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários

Page generated in 0.0769 seconds