• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 2
  • Tagged with
  • 11
  • 11
  • 7
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo de algumas variaveis de processamento na resistencia mecanica a flexao de refratarios de SiC ligado a Sisub(3)Nsub(4)

MATSUDA, SIGUERU O. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:23Z (GMT). No. of bitstreams: 1 06908.pdf: 2703320 bytes, checksum: 38c6007057a454b93e257e7f851f366a (MD5) / Dissertacao [Mestrado] / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
2

Efeito do envelhecimento por ciclagem mecânica ou ciclagem em autoclave na resistência à flexão de cerâmicas odontológicas / Mechanical and autoclave cycling effect on flexural strength of dental ceramics

Okada, Cristina Yuri 29 January 2010 (has links)
Os objetivos deste trabalho foram: a) realizar a análise microestrutural de cerâmicas odontológicas e relacioná-la aos valores de resistência à flexão obtidos, b) avaliar o efeito de dois tipos de envelhecimento (ciclagem mecânica e ciclagem em autoclave) sobre a resistência à flexão desses materiais e c) avaliar se a configuração do espécime (discos versus barras) é capaz de alterar o efeito da ciclagem mecânica sobre a resistência à flexão. Cinco materiais foram utilizados: zircônia tetragonal policristalina estabilizada por ítrio (YZ), alumina policristalina (AL), alumina infiltrada por vidro/reforçada por zircônia (ICZ) e duas porcelanas (VM7 e VM9). Espécimes em forma de barra (2 x 4 x 16 mm) e disco (12 mm x 2 mm) foram confeccionados conforme as recomendações dos fabricantes. A densidade foi determinada pelo método de Arquimedes, as constantes elásticas foram determinadas pelo método do pulso-eco ultrassônico. Microscopia óptica e eletrônica de varredura foram utilizadas para determinar a fração e tamanho médio de poros e partículas e a análise de EDS para a realização de análise química dos microconstituintes. O efeito do envelhecimento por ciclagem mecânica (YZ, AL e ICZ: 80 N por 105 ciclos e VM7 e VM9: 45 N por 104 ciclos, a 2 Hz) ou por ciclagem em autoclave a 134°C, pressão de 2,2 kgf/cm2 durante 5h, foi avaliado nos espécimes em forma de barra e comparados com um grupo controle, não ciclado. O efeito do envelhecimento por ciclagem mecânica foi comparado entre os espécimes em forma de barra e disco para as porcelanas estudadas. Houve diferenças significativas entre os valores de resistência em função do material, causadas pelas diferenças em sua microestrutura, sendo que as porcelanas apresentam baixos valores de resistência (VM7: 69,4 MPa e VM9: 64,7 MPa), enquanto que a AL e a ICZ apresentaram valores intermediários (462,8 MPa e 408,6 MPa, respectivamente) e a YZ apresentou o maior valor de resistência à flexão (869 MPa). Após a ciclagem mecânica, somente o material AL apresentou redução estatisticamente significativa da resistência à flexão (389,2 MPa). A ciclagem em autoclave não resultou em degradação significativa da resistência de nenhum dos materiais testados. A configuração do espécime (barra ou disco) não alterou o efeito da ciclagem mecânica sobre a resistência das porcelanas testadas (nenhum material apresentou queda da resistência após ciclagem). Entretanto, nos espécimes em forma de disco a resistência à flexão da VM7 foi significativamente maior que a da VM9 (69,6 MPa e 57,6 MPa, respectivamente), enquanto que nos espécimes em forma de barra não houve diferença estatística entre os valores de resistência das duas porcelanas (VM7: 61,1 MPa e VM9: 68,8 MPa). / The aims of this study were: to perform a microestrutural analysis of dental ceramics and correlate the results with the flexural strength obtained; to evaluate two aging process (mechanical cycling and autoclave cycling) on the flexural strength of the materials and to evaluate the specimen configuration (bar or disc) on the flexural strength of mechanical cycling aged specimens. The five ceramics tested were: yttria-stabilized zirconia (YZ), polycrystalline alumina (AL), glass-infiltrated alumina/zirconia reinforced (ICZ) and two dental porcelains (VM7 and VM9). Bars (2 x 4 x 16 mm) and discs (12 mm x 2 mm) were produced according to the manufactures instructions. Density was obtained by Arquimedes method and the elastics constants were obtained by ultrasonic pulse-echo method. Optical and Scanning Electron Microscope were used to determine the fraction and size of both pores and particles while the chemical composition was obtained by EDS. Aging effect on flexural strength after mechanical or autoclave cycling was evaluated on bar specimens and compared to a control group, which was not cycled. The specimen configurations (bars or discs) were compared after mechanical cycling for porcelains. Microestrutural differences between material resulted on flexural strength values statistically different, porcelains presented lower values of flexural strength (VM7: 69,4 MPa and VM9: 64,7 MPa), while AL and ICZ presented intermediate flexural strength (462,8 MPa and 408,6 MPa, respectively) and YZ presented the highest flexural strength (869 MPa). Only AL presented a significant lower flexural strength after mechanical cycling (389,2 MPa). Autoclave cycling did not influence the flexural strength of the studied materials. Also, the specimen configuration did not influence the flexural strength values before or after mechanical cycling. It should be noted that disc specimens of VM7 presented significantly higher flexural strength values than VM9 (69,6 MPa and 57,6 MPa, respectively), however for bar specimens no statistical difference was noted between the mean strength of both porcelains (VM7: 61,1 MPa and VM9: 68,8 MPa).
3

"Estudo das resinas acrílicas para bases de próteses totais com relação à resistência flexural, e à quantidade de monômero residual superficial" / Study of acrylic resin for complete denture considering flexural strength and quantity of superficial residual mono mer

Paes Junior, Tarcisio José de Arruda 16 June 2005 (has links)
O objetivo deste trabalho foi o de avaliar a resistência à flexão e a quantidade de monômero residual superficial em resinas acrílicas para bases de próteses totais. Para tanto foram confeccionados corpos-de-prova nas dimensões de 2.5mm x 10mm x 65mm, utilizados em ambas as análises. Padronizou-se o processo de inclusão no qual foram empregadas muflas plásticas reforçadas por fibras de vidro. Sete grupos foram constituídos, de acordo com o tipo de processamento empregado na polimerização das resinas: Ac (Acron-MC) e Vw (Vipi-Wave) de ativação por energia de microondas; Lt (Lucitone 550 – grupo controle) e Vc (Vipi-Cril), resinas de ativação térmica convencional em banho de água aquecida no ciclo longo; Qc (QC-20), uma resina de ativação térmica em ciclo rápido e, dois grupos cuja resina era a mesma de ativação química (Vipi-Flash), processada em duas condições – à temperatura ambiente (Vf1) e, por aquecimento adicional em banho de água (Vf2). Os resultados mostraram diferenças estatisticamente significantes, onde o grupo Ac obteve as maiores médias para resistência flexural e os menores níveis de monômero liberado em relação às demais resinas. Os grupos Qc e Vf1 evidenciaram os piores resultados para ambos os testes, e a princípio, pareceu haver uma relação de causa e efeito entre, os elevados níveis de monômero residual encontrado nestes grupos, e a baixa resistência flexural observada. Verificou-se ainda que a imersão em água aquecida por 30min, da resina de ativação química, propiciou um ganho em qualidade do material para as características avaliadas. / The purpose of this work was the evaluation of flexural strength and quantity of superficial residual monomer in acrylic resin for complete denture. To perform both analyses it was developed specimens with a dimension of 2.5mm x 10mm x 65mm. The inclusion process was standardized by the use of plastic flasks reinforced with fiberglass. Seven groups were constituted in accordance with the type of resin polymerization process: Ac (Acron-MC) and Vw (Vipi-Wave) activated by microwave energy; Lt (Lucitone 550 – control group) and Vc (Vipi-Cril), conventional water bath curing cycles of heat activated acrylic resin; Qc (QC-20), fast cycle thermal activation; and two groups of self cured resin (Vipi-Flash), processed in two distinguished conditions: ambient temperature (Vf1) and additional heating in water bath (Vf2). The results have shown statistical significant differences. The Ac group had the highest mean to flexural resistance and the least level of released monomer in comparison with others resins. The Qc and Vf1 groups had the worst results for both tests. The initial conclusions showed a cause-effect relation between higher levels of residual monomer and lower flexural strength to this group. Additionally, it was verified that the immersion for 30 minutes of self cured resin in heated water gave an improvement of material quality to evaluated characteristics.
4

"Estudo das resinas acrílicas para bases de próteses totais com relação à resistência flexural, e à quantidade de monômero residual superficial" / Study of acrylic resin for complete denture considering flexural strength and quantity of superficial residual mono mer

Tarcisio José de Arruda Paes Junior 16 June 2005 (has links)
O objetivo deste trabalho foi o de avaliar a resistência à flexão e a quantidade de monômero residual superficial em resinas acrílicas para bases de próteses totais. Para tanto foram confeccionados corpos-de-prova nas dimensões de 2.5mm x 10mm x 65mm, utilizados em ambas as análises. Padronizou-se o processo de inclusão no qual foram empregadas muflas plásticas reforçadas por fibras de vidro. Sete grupos foram constituídos, de acordo com o tipo de processamento empregado na polimerização das resinas: Ac (Acron-MC) e Vw (Vipi-Wave) de ativação por energia de microondas; Lt (Lucitone 550 – grupo controle) e Vc (Vipi-Cril), resinas de ativação térmica convencional em banho de água aquecida no ciclo longo; Qc (QC-20), uma resina de ativação térmica em ciclo rápido e, dois grupos cuja resina era a mesma de ativação química (Vipi-Flash), processada em duas condições – à temperatura ambiente (Vf1) e, por aquecimento adicional em banho de água (Vf2). Os resultados mostraram diferenças estatisticamente significantes, onde o grupo Ac obteve as maiores médias para resistência flexural e os menores níveis de monômero liberado em relação às demais resinas. Os grupos Qc e Vf1 evidenciaram os piores resultados para ambos os testes, e a princípio, pareceu haver uma relação de causa e efeito entre, os elevados níveis de monômero residual encontrado nestes grupos, e a baixa resistência flexural observada. Verificou-se ainda que a imersão em água aquecida por 30min, da resina de ativação química, propiciou um ganho em qualidade do material para as características avaliadas. / The purpose of this work was the evaluation of flexural strength and quantity of superficial residual monomer in acrylic resin for complete denture. To perform both analyses it was developed specimens with a dimension of 2.5mm x 10mm x 65mm. The inclusion process was standardized by the use of plastic flasks reinforced with fiberglass. Seven groups were constituted in accordance with the type of resin polymerization process: Ac (Acron-MC) and Vw (Vipi-Wave) activated by microwave energy; Lt (Lucitone 550 – control group) and Vc (Vipi-Cril), conventional water bath curing cycles of heat activated acrylic resin; Qc (QC-20), fast cycle thermal activation; and two groups of self cured resin (Vipi-Flash), processed in two distinguished conditions: ambient temperature (Vf1) and additional heating in water bath (Vf2). The results have shown statistical significant differences. The Ac group had the highest mean to flexural resistance and the least level of released monomer in comparison with others resins. The Qc and Vf1 groups had the worst results for both tests. The initial conclusions showed a cause-effect relation between higher levels of residual monomer and lower flexural strength to this group. Additionally, it was verified that the immersion for 30 minutes of self cured resin in heated water gave an improvement of material quality to evaluated characteristics.
5

Efeito do envelhecimento por ciclagem mecânica ou ciclagem em autoclave na resistência à flexão de cerâmicas odontológicas / Mechanical and autoclave cycling effect on flexural strength of dental ceramics

Cristina Yuri Okada 29 January 2010 (has links)
Os objetivos deste trabalho foram: a) realizar a análise microestrutural de cerâmicas odontológicas e relacioná-la aos valores de resistência à flexão obtidos, b) avaliar o efeito de dois tipos de envelhecimento (ciclagem mecânica e ciclagem em autoclave) sobre a resistência à flexão desses materiais e c) avaliar se a configuração do espécime (discos versus barras) é capaz de alterar o efeito da ciclagem mecânica sobre a resistência à flexão. Cinco materiais foram utilizados: zircônia tetragonal policristalina estabilizada por ítrio (YZ), alumina policristalina (AL), alumina infiltrada por vidro/reforçada por zircônia (ICZ) e duas porcelanas (VM7 e VM9). Espécimes em forma de barra (2 x 4 x 16 mm) e disco (12 mm x 2 mm) foram confeccionados conforme as recomendações dos fabricantes. A densidade foi determinada pelo método de Arquimedes, as constantes elásticas foram determinadas pelo método do pulso-eco ultrassônico. Microscopia óptica e eletrônica de varredura foram utilizadas para determinar a fração e tamanho médio de poros e partículas e a análise de EDS para a realização de análise química dos microconstituintes. O efeito do envelhecimento por ciclagem mecânica (YZ, AL e ICZ: 80 N por 105 ciclos e VM7 e VM9: 45 N por 104 ciclos, a 2 Hz) ou por ciclagem em autoclave a 134°C, pressão de 2,2 kgf/cm2 durante 5h, foi avaliado nos espécimes em forma de barra e comparados com um grupo controle, não ciclado. O efeito do envelhecimento por ciclagem mecânica foi comparado entre os espécimes em forma de barra e disco para as porcelanas estudadas. Houve diferenças significativas entre os valores de resistência em função do material, causadas pelas diferenças em sua microestrutura, sendo que as porcelanas apresentam baixos valores de resistência (VM7: 69,4 MPa e VM9: 64,7 MPa), enquanto que a AL e a ICZ apresentaram valores intermediários (462,8 MPa e 408,6 MPa, respectivamente) e a YZ apresentou o maior valor de resistência à flexão (869 MPa). Após a ciclagem mecânica, somente o material AL apresentou redução estatisticamente significativa da resistência à flexão (389,2 MPa). A ciclagem em autoclave não resultou em degradação significativa da resistência de nenhum dos materiais testados. A configuração do espécime (barra ou disco) não alterou o efeito da ciclagem mecânica sobre a resistência das porcelanas testadas (nenhum material apresentou queda da resistência após ciclagem). Entretanto, nos espécimes em forma de disco a resistência à flexão da VM7 foi significativamente maior que a da VM9 (69,6 MPa e 57,6 MPa, respectivamente), enquanto que nos espécimes em forma de barra não houve diferença estatística entre os valores de resistência das duas porcelanas (VM7: 61,1 MPa e VM9: 68,8 MPa). / The aims of this study were: to perform a microestrutural analysis of dental ceramics and correlate the results with the flexural strength obtained; to evaluate two aging process (mechanical cycling and autoclave cycling) on the flexural strength of the materials and to evaluate the specimen configuration (bar or disc) on the flexural strength of mechanical cycling aged specimens. The five ceramics tested were: yttria-stabilized zirconia (YZ), polycrystalline alumina (AL), glass-infiltrated alumina/zirconia reinforced (ICZ) and two dental porcelains (VM7 and VM9). Bars (2 x 4 x 16 mm) and discs (12 mm x 2 mm) were produced according to the manufactures instructions. Density was obtained by Arquimedes method and the elastics constants were obtained by ultrasonic pulse-echo method. Optical and Scanning Electron Microscope were used to determine the fraction and size of both pores and particles while the chemical composition was obtained by EDS. Aging effect on flexural strength after mechanical or autoclave cycling was evaluated on bar specimens and compared to a control group, which was not cycled. The specimen configurations (bars or discs) were compared after mechanical cycling for porcelains. Microestrutural differences between material resulted on flexural strength values statistically different, porcelains presented lower values of flexural strength (VM7: 69,4 MPa and VM9: 64,7 MPa), while AL and ICZ presented intermediate flexural strength (462,8 MPa and 408,6 MPa, respectively) and YZ presented the highest flexural strength (869 MPa). Only AL presented a significant lower flexural strength after mechanical cycling (389,2 MPa). Autoclave cycling did not influence the flexural strength of the studied materials. Also, the specimen configuration did not influence the flexural strength values before or after mechanical cycling. It should be noted that disc specimens of VM7 presented significantly higher flexural strength values than VM9 (69,6 MPa and 57,6 MPa, respectively), however for bar specimens no statistical difference was noted between the mean strength of both porcelains (VM7: 61,1 MPa and VM9: 68,8 MPa).
6

Desenvolvimento de um sistema de protecao antioxidante para o composito carbono-carbono

CAIRO, CARLOS A.A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:02Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:48Z (GMT). No. of bitstreams: 1 06176.pdf: 9306804 bytes, checksum: c8d5e9d8cf888b1ed0725717af3c2309 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
7

Influência do método experimental na resistência flexural de materiais restauradores: ensaio mecânico, análise por elementos finitos e fractografia

Pains, Marcos Barbosa 21 December 2011 (has links)
Besides the differences in chemical composition, which has a direct influence on the mechanical properties of restorative materials, the various methods of evaluation have generated different results that make it difficult any comparison among their properties. The aim of this study was to determine and compare the flexural strength (FS) of four restorative materials and the influence of the measurement method in such property. Twelve groups (n=15) were obtained and each tested material (Filtek Z350, Epricord, Super Porcelain EX-3 and IPS Empress 2) was submitted to three mechanical tests to assess their FS. For three and four-point bending tests rectangular beams (25x2x2 mm) was used and disc-shaped (12x1,2 mm) was used in the biaxial test. Specimens were submitted to load at the 1 mm/min speed in an EMIC machine, the analysis of stress distribution was performed by 3D finite element analysis and fracture site was visually evaluated. Mean values of FS were obtained from the fracture load of the samples and subjected to statistical analysis. Two-way ANOVA and Tukey's test indicated significant differences between the materials with higher values for IPS Empress 2 (a), followed by Filtek Z350 (b) in all methods, followed by Super Porcelain EX-3 (c) and Epricord (d) in two of three tests. Three-point bending and biaxial tests showed significantly higher values (A), while the four-point bending test was inferior (B). Fracture modes observed correlated with the finite element analysis. Results indicated reliability of all methods, supported by reasonably low coefficients of variation and the highest values of the materials further strengthened in its composition. However, due to lower sensitivity, lower reproducibility (higher coefficient of variation) and greater difficulty of implementation, the four-point bending test seems to be less suitable. / Além das diferenças na composição química, que tem influência direta nas propriedades mecânicas dos materiais restauradores, os diversos métodos de avaliação têm gerado diferentes resultados que dificultam qualquer comparação entre as propriedades dos materiais. O objetivo desse trabalho foi determinar e comparar a resistência flexural (RF) de quatro materiais restauradores e a influência do método na mensuração. Foram obtidos 12 grupos (n=15) sendo que cada material (Filtek Z350, Epricord, Super Porcelain EX-3, e IPS Empress 2) foi submetido a três ensaios de avaliação da RF. Para os ensaios de três e quatro pontos foram obtidas amostras em forma de barras retangulares (25x2x2 mm) e para o biaxial, amostras em forma de disco (12x1,2 mm). Os ensaios foram realizados em máquina EMIC à velocidade de 1 mm/min, a análise da distribuição de tensões foi realizada por elementos finitos em 3D e o local da fratura foi visualmente avaliado. Os valores médios de RF foram obtidos a partir da carga de fratura das amostras e submetidos à análise estatística. Two way ANOVA e teste de Tukey indicaram diferenças significativas entre os materiais com maiores valores para o IPS Empress 2 (a), seguido da resina Filtek Z350 (b) em todos os métodos, seguidos de Super Porcelain EX-3 (c) e Epricord (d) em dois dos três ensaios. Os ensaios de três pontos e biaxial apresentaram valores significativamente maiores (A), enquanto que o de quatro pontos apresentou resultados inferiores (B). Os padrões de fratura observados estão correlacionados com a análise de elementos finitos. Os resultados indicaram confiabilidade de todos os métodos, suportada pelos coeficientes de variação razoavelmente baixos e pelos maiores valores dos materiais mais reforçados em sua composição. Porém, devido a menor sensibilidade, menor reprodutibilidade (maior coeficiente de variação) e maior dificuldade de execução, o ensaio flexural de quatro pontos parece ser o menor indicado. / Mestre em Odontologia
8

Studium odolnosti lepené spáry dřeva proti vyšším teplotám / Study of durability of wood glue bonds against increased temperature

Kučera, Vít January 2017 (has links)
In this time are for design of wooden elements available simplified procedures for fire modeling which defines ČSN EN 1991-1-2. But it is not experimentally tested the impact of adhesive on the final value of fire resistance of laminated panels. This diploma thesis solves basic normative practices that could explain the durability of glue bond against increased temperatures. in the practical part will be undertaken to experimentally assess the impact of various kinds of adhesive-based (epoxy, formaldehyde, PUR and EPI) on the glued bond durability against increased temperature. Glued joints that will be subjected to gradual temperature exposure in order to assemble the dependence of the temperature influence on the final strength of the joint according to the type of adhesive.
9

\"Avaliação da resistência flexural, microinfiltração e grau de conversão de uma resina composta fotoativada com luz halógena e laser de argônio\" / Evaluation of the flexural strenght, microleakage and degree of convertion of a composite resin photocured with argon laser and halogen lamp.

Lloret, Patricia Ramos 13 February 2007 (has links)
Nesta pesquisa foi avaliado a resistência flexural, a microinfiltração e o grau de conversão de uma resina composta micro-híbrida fotoativada por laser de argônio e luz halógena. Para o teste de resistência flexural e grau de conversão foram preparadas cinco amostras de 25 X 2 X 2mm de acordo com a norma ISO 4049. Os parâmetros de fotoativação utilizados em todas as etapas do trabalho foram: luz halógena (500mW/cm2) por 20 segudos, laser de argônio (250mW) por 10 e 20 segundos. As amostras foram lixadas com a seqüência de granulações 500, 800, 1000, 1200, 2500 e 4000. Os espécimes eram armazenados em água destilada, em recipiente escuro, em estufa a 37ºC por 24 horas e eram submetidos ao ensaio de resistência flexural (Máquina de Ensaios Mecânicos - Modelo 4411 ? Instron) em velocidade de 1mm/min. Para o estudo da microinfiltração foram utilizados dentes incisivos bovinos (n=20), As cavidades eram preparadas com brocas Carbide #330 com 4mm (altura) X 3mm (largura) X 2mm (profundidade). Os dentes eram então restaurados, e recebiam acabamento e polimento e em seguida eram armazenados em água destilada, em estufa a 37ºC por 24 horas. As amostras foram submetidas ao processo de termociclagem (500 ciclos de 30 segundos - 6ºC e 60ºC). Após a termociclagem, os ápices dos dentes eram selados com IRM e adesivo a base de cianoacrilato e imersos em fucsina básica a 0,5% por 24 horas, em estufa a 37ºC. A análise do grau de conversão foi feita com o Espectrômetro FT-Raman RFS 100/S (Bruker). Para o teste de resistência flexural foi realizado o teste de análise de variância, que mostrou não haver diferença estatisticamente significante entre as fontes fotoativadoras estudadas (p>0,05). A microinfiltração das margens oclusais (em esmalte) e gengivais (em dentina) dos três grupos foram analisadas separadamente por meio do teste de Mann-Whitney. Houve diferença estatisticamente significante ao nível de 5% entre esmalte e dentina, sendo que em todos os grupos a microinfiltração em dentina foi maior que em esmalte. O teste nãoparamétrico Kruskall-Wallis foi utilizado separadamente nas comparações entre as fontes para as análises do grau de microinfiltração em esmalte e dentina. Não houve diferença estatisticamente significante em ambas as comparações, sendo o valor de H= 0,1283 para esmalte e de H=2,3083 para em dentina. Para a análise do grau de conversão foi realizada a análise de variância (ANOVA) entre os grupos. Não houve diferença estatisticamente significante entre as fontes. Diante dos resultados obtidos, pode-se afirmar que o laser de argônio apresentou qualidade de fotoativação semelhante à da luz halógena e que nenhuma fonte ativadora estudada foi capaz de evitar a microinfiltração. / In the research was evaluated the flexural strength, the microleakage and the degree of conversion of a micro-hybrid composite resin photocured with argon laser and halogen lamp. For both flexural test and degree of conversion analysis five bar samples of composite resin (25 X 2 X 2mm) were prepared and polymerized following the ISO 4049. The light cured unit halogen was used with 500mW/cm2 for 20 seconds and the argon laser with 250mW for 10 and 20 seconds. After curing, samples were removed from the molds, polished using silicon carbide paper up to 4000 grit-number and stored in distilled water in dark environment at 37oC for 24 hours. The flexural property was quantified by a three-point loading test (Model 4411, Instron Corp., Canton, MA) with a cross-head speed of 1,0mm/min. To microleakage test sixty bovine incisors were used to prepare standardized class V cavities that were restored and polished. The specimens were stored in water for 24 hours at 37oC and thermocycled 500 times between water baths kept at 5 oC and 55 oC. After thermocycling, specimens were immersed in a aqueous solution of basic fuchsin for 24 hours. Longitudinal sections of each restoration were obtained and examined with a stereomicroscope for qualitive evaluation of microleakage. FTRaman RFS 100/S spectrometer (Bruker) was used to analyse the degree of conversion. The ANOVA test showed that there were no statistically significant difference of the flexural setrength between the photo-activation types evaluated in the flexural study. Microleakage data was statistically analysed by Mann-Whitney and Kruskall-Wallis tests. Enamel margins resulted in statistical lower degree of leakage than dentin margins. There was no statistically significant difference between the three types of photo-curing studied. The ANOVA test also showed that there were no statistically significant difference of the degree of conversion between the studied groups. According to the methodology used in this research it was concluded that the argon laser is a posible alternative for photocuring, providing the same quality of polymerization as do the halogen lamp. None of the photocured units tested in this study completely eliminated microleakage.
10

\"Avaliação da resistência flexural, microinfiltração e grau de conversão de uma resina composta fotoativada com luz halógena e laser de argônio\" / Evaluation of the flexural strenght, microleakage and degree of convertion of a composite resin photocured with argon laser and halogen lamp.

Patricia Ramos Lloret 13 February 2007 (has links)
Nesta pesquisa foi avaliado a resistência flexural, a microinfiltração e o grau de conversão de uma resina composta micro-híbrida fotoativada por laser de argônio e luz halógena. Para o teste de resistência flexural e grau de conversão foram preparadas cinco amostras de 25 X 2 X 2mm de acordo com a norma ISO 4049. Os parâmetros de fotoativação utilizados em todas as etapas do trabalho foram: luz halógena (500mW/cm2) por 20 segudos, laser de argônio (250mW) por 10 e 20 segundos. As amostras foram lixadas com a seqüência de granulações 500, 800, 1000, 1200, 2500 e 4000. Os espécimes eram armazenados em água destilada, em recipiente escuro, em estufa a 37ºC por 24 horas e eram submetidos ao ensaio de resistência flexural (Máquina de Ensaios Mecânicos - Modelo 4411 ? Instron) em velocidade de 1mm/min. Para o estudo da microinfiltração foram utilizados dentes incisivos bovinos (n=20), As cavidades eram preparadas com brocas Carbide #330 com 4mm (altura) X 3mm (largura) X 2mm (profundidade). Os dentes eram então restaurados, e recebiam acabamento e polimento e em seguida eram armazenados em água destilada, em estufa a 37ºC por 24 horas. As amostras foram submetidas ao processo de termociclagem (500 ciclos de 30 segundos - 6ºC e 60ºC). Após a termociclagem, os ápices dos dentes eram selados com IRM e adesivo a base de cianoacrilato e imersos em fucsina básica a 0,5% por 24 horas, em estufa a 37ºC. A análise do grau de conversão foi feita com o Espectrômetro FT-Raman RFS 100/S (Bruker). Para o teste de resistência flexural foi realizado o teste de análise de variância, que mostrou não haver diferença estatisticamente significante entre as fontes fotoativadoras estudadas (p>0,05). A microinfiltração das margens oclusais (em esmalte) e gengivais (em dentina) dos três grupos foram analisadas separadamente por meio do teste de Mann-Whitney. Houve diferença estatisticamente significante ao nível de 5% entre esmalte e dentina, sendo que em todos os grupos a microinfiltração em dentina foi maior que em esmalte. O teste nãoparamétrico Kruskall-Wallis foi utilizado separadamente nas comparações entre as fontes para as análises do grau de microinfiltração em esmalte e dentina. Não houve diferença estatisticamente significante em ambas as comparações, sendo o valor de H= 0,1283 para esmalte e de H=2,3083 para em dentina. Para a análise do grau de conversão foi realizada a análise de variância (ANOVA) entre os grupos. Não houve diferença estatisticamente significante entre as fontes. Diante dos resultados obtidos, pode-se afirmar que o laser de argônio apresentou qualidade de fotoativação semelhante à da luz halógena e que nenhuma fonte ativadora estudada foi capaz de evitar a microinfiltração. / In the research was evaluated the flexural strength, the microleakage and the degree of conversion of a micro-hybrid composite resin photocured with argon laser and halogen lamp. For both flexural test and degree of conversion analysis five bar samples of composite resin (25 X 2 X 2mm) were prepared and polymerized following the ISO 4049. The light cured unit halogen was used with 500mW/cm2 for 20 seconds and the argon laser with 250mW for 10 and 20 seconds. After curing, samples were removed from the molds, polished using silicon carbide paper up to 4000 grit-number and stored in distilled water in dark environment at 37oC for 24 hours. The flexural property was quantified by a three-point loading test (Model 4411, Instron Corp., Canton, MA) with a cross-head speed of 1,0mm/min. To microleakage test sixty bovine incisors were used to prepare standardized class V cavities that were restored and polished. The specimens were stored in water for 24 hours at 37oC and thermocycled 500 times between water baths kept at 5 oC and 55 oC. After thermocycling, specimens were immersed in a aqueous solution of basic fuchsin for 24 hours. Longitudinal sections of each restoration were obtained and examined with a stereomicroscope for qualitive evaluation of microleakage. FTRaman RFS 100/S spectrometer (Bruker) was used to analyse the degree of conversion. The ANOVA test showed that there were no statistically significant difference of the flexural setrength between the photo-activation types evaluated in the flexural study. Microleakage data was statistically analysed by Mann-Whitney and Kruskall-Wallis tests. Enamel margins resulted in statistical lower degree of leakage than dentin margins. There was no statistically significant difference between the three types of photo-curing studied. The ANOVA test also showed that there were no statistically significant difference of the degree of conversion between the studied groups. According to the methodology used in this research it was concluded that the argon laser is a posible alternative for photocuring, providing the same quality of polymerization as do the halogen lamp. None of the photocured units tested in this study completely eliminated microleakage.

Page generated in 0.0495 seconds