• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 232
  • 17
  • 12
  • 12
  • 12
  • 12
  • 11
  • 7
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 267
  • 267
  • 220
  • 218
  • 79
  • 76
  • 74
  • 74
  • 64
  • 60
  • 57
  • 54
  • 34
  • 34
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Avaliação da resistência ao cisalhamento e da durabilidade de união entre sistemas para reparo em metalocerâmicas e titânio

Haneda, Isabella Gagliardi [UNESP] 25 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-25Bitstream added on 2014-06-13T19:05:05Z : No. of bitstreams: 1 haneda_ig_dr_arafo.pdf: 1539372 bytes, checksum: 1d44db42b17bfb741258df69baa7591c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O reparo de restaurações metalocerâmicas fraturadas é uma opção de tratamento que possibilita o aumento da longevidade da restauração, preservando a estrutura dental, além de ser uma alternativa rápida e de menor custo. Entretanto, o estabelecimento de uma união forte e estável entre material reparador e substrato da restauração fraturada é essencial para o sucesso do reparo. Levando-se em consideração a grande utilidade dos reparos quando corretamente indicados e a possibilidade de um aprimoramento dos mesmos com esses novos sistemas, conforme prometem os fabricantes, foi propósito deste estudo avaliar, em titânio comercialmente puro, a resistência ao cisalhamento de quatro sistemas comerciais de reparo para metalocerâmicas e da variação de um destes, bem como a durabilidade de união após armazenamento em água. Foram confeccionados discos (9 × 3 mm) em titânio comercialmente puro. Estes foram incluídos em anel de PVC com resina acrílica e suas superfícies regularizadas com lixas de carbeto de silício de diferentes granulações (120, 220 e 320) em politriz. Os espécimes receberam um dos seguintes tratamentos (n=10): 1) Epricord, 2) Bistite II DC, 3) Cojet, 4) Scotchbond Multi Uso Plus (grupo Controle), e 5) uma variação do grupo Controle, na qual foram empregadas partículas de sílica do sistema Cojet Sand em substituição às de óxido de alumínio. Os espécimes foram armazenados em água destilada a 37ºC por 24 horas, termociclados (5.000 ciclos - 5º e 55ºC) e, então, armazenados nas mesmas condições descritas anteriormente, por um período adicional de 24 horas ou 6 meses. O ensaio de cisalhamento foi realizado em máquina de ensaios Material Test System 810 com velocidade de 0,5 mm/minuto. O modo da fratura foi avaliado em lupa estereoscópica (30x). Às 24 horas, as médias... / Repair is a good alternative treatment that can increase clinical longevity of the failed restoration, preserving tooth structure, with the advantages of less chair time and lower cost. However, the clinical success of repair depends on establishing a strong and longterm durable bond between the repair material and the metal surface of the failed restoration. Considering the great benefit of intra-oral repairs and the possibility of improvement with the use of new available repair systems, the purpose of the present study was to evaluate shear bond strength of different repair systems to commercially pure titanium (CP Ti) and bond durability after long-term water storage. One-hundred disk specimens of cast CP Ti (9 × 3 mm) were embedded in a PVC ring and their bonding surfaces were smoothed with silicon carbide papers (120, 220, and 320 grit) using a polisher. Specimens were divided into 5 groups of 20, which received one of the following repair systems: 1) Epricord, 2) Bistite II DC 3) Cojet, 4) Scotchbond Multipurpose Plus (control Group), and 5) Cojet Sand plus Scotchbond Multipurpose Plus (variation of the control Group). The specimens were stored in distilled water for 24 hours at 37ºC, thermal cycled (5,000 cycles – 5º to 55ºC) and then stored in distilled water at 37o C for either 24 hours or 6 months. Shear bond tests were performed in a mechanical testing machine with a crosshead speed of 0.5 mm/minute. Each specimen was examined under a stereoscopic lens with ×30 magnification. At 24 hours, the mean values (MPa) for the groups 1 to 5 were respectively 13,00 + 2,04c, 8,10 + 1,16d, 18,34 + 2,16b, 13,41 + 1,42c, e 22,73 + 1,42a. After 6 months, the mean (MPa) of each... (Complete abstract click electronic access below)
102

Influência do tipo de pilar de resistência mecânica pré-ciclagem, quantidade de toque retido e desajuste vertical pré e pós-ciclagem, com análise estrutural em MEV

Butignon, Luís Eduardo [UNESP] 20 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-20Bitstream added on 2014-06-13T19:05:07Z : No. of bitstreams: 1 butignon_le_dr_arafo.pdf: 1153386 bytes, checksum: 16702ac969f619bac97fc05d42b19652 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Problemática: De ocorrência clínica comum, o afrouxamento dos parafusos que compõe uma prótese sobre implante é uma complicação que traz transtornos tanto para o profissional quanto para o paciente. Entre os fatores que interferem na estabilidade da união parafusada destaca-se a pré-carga gerada durante o torque do parafuso, as formas como as forças se dissipam através do conjunto implante/pilar/parafuso e as características dos componentes utilizados. Proposição: O objetivo deste estudo foi analisar comparativamente três tipos de pilares sobre implantes, quanto a resistência mecânica previamente ao ensaio de carga cíclica; a porcentagem de torque retido na união parafusada e os níveis de desajuste vertical entre o pilar e o implante antes e após ciclagem; e alterações estruturais na base de assentamento dos pilares através de microscopia eletrônica de varredura (MEV). Material e método: Quarenta e cinco implantes, com conexão tipo hexágono externo foram incluídos em cilindros de PVC utilizando-se resina epóxica com módulo de elasticidade semelhante à estrutura óssea. Os grupos foram estabelecidos de acordo com o tipo de pilar utilizado (n=15): Titânio (pré-fabricado), Ouro (com cinta metálica pré-fabricada e sobre fundido) e Zircônia (pré-fabricado). Cinco pilares de cada grupo foram submetidos a teste de resistência estática para estabelecimento do valor da força a ser utilizada no ensaio de carga cíclica. Os outros 10 pilares de cada grupo foram fixados sobre os respectivos implantes através de parafuso de titânio, sob torque e retorque de 32 Ncm (pilares metálicos) e 20 Ncm (pilar de zircônia). Os corpos de prova foram submetidos à aferição do torque retido (précarga) e dos níveis de desajuste vertical... / Purpose: The aim of this study was to evaluate comparatively three type of abutment in regard to mechanical resistance before cyclic loading, the maintenance of the applied torque and vertical misfit in abutment/implant interface before and after cyclic loading, and damage surface by SEM. Material and Method: Forty five external hex implants were embedded in an epoxy resin and received your respective abutments, randomly divided in three experimental groups (n=15): (A) machined titanium (Ti) abutments; (B) premachined gold (Au) abutments and (C) machined zirconia (ZrO2) abutments. For all groups, only one type of screw was used. The abutment screws were tightened according to the manufacture’s recommended torque. Initially, a static bending test was performed using 5 specimens of each group to determine the load applied in the cyclic loading test. Thus, 10 specimens of each group were used to measure the reverse torque value (preload) of the abutment screw and vertical gap between the abutments and implant, before and after loading. The tests were performed according to ISO norm 14801. A cyclic loading (0,5 x 106 cycles; 15 Hz) between 11 - 211 N was applied at an angle of 30 degrees to the long axis of the implants. Group means were compared using ANOVA and Tukey test. Result: The mechanical strength test showed that the UFL mean for Au abutments was significantly higher than the mean of the other abutments (p<0.001). The analysis of reverse torque (preload) before cyclic loading showed no significant differences among abutment groups. After cyclic loading the lowest decrease in preload was observed in group Ti, whereas the highest was observed in group ZrO2, with significant differences between them. The group Au showed an intermediate decrease, with no significant difference to the other groups. In relation to the vertical misfit... (Complete abstract click electronic access below)
103

Movimentação dos dentes artificiais em próteses totais com diferentes profundidades de palato

Vedovatto, Eduardo [UNESP] 25 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-25Bitstream added on 2014-06-13T19:24:19Z : No. of bitstreams: 1 vedovatto_e_dr_araca.pdf: 365938 bytes, checksum: bd1dd616abe7c6a4bce474ab109acd1f (MD5) / Demonstração do problema: alterações oclusais sempre ocorrem durante o processamento de próteses totais, entretanto, o deslocamento do dente no sentido ocluso-cervical e sua relação com a profundidade do palato ainda não foi totalmente evidenciada. Objetivos: esse estudo investigou a movimentação dos segundos molares superiores em próteses totais processadas com resina acrílica, com diferentes profundidades de palato e com diferentes materiais de inclusão. Métodos: vinte e oito próteses totais superiores idênticas foram confeccionadas sobre o modelo com palato raso e vinte e oito próteses sobre o modelo com palato profundo. Essas próteses foram divididas em quatro grupos com 14 unidades de acordo com o tipo de palato e o tipo de material de inclusão (gesso ou silicone). Foram demarcados pontos na face distal dos segundos molares e no modelo como referência para a mensuração do deslocamento dos dentes. O deslocamento vertical, horizontal e angular foi verificado através das imagens das próteses com o programa AutoCad em dois momentos: antes da inclusão em mufla e depois da demuflagem (sem a separação do modelo). Os valores foram submetidos ao tratamento estatístico de Kolmogorov- Smirnov e ANOVA com o Tukey e Fisher post hoc test a 5% de significância. Resultados: Os resultados não mostraram diferença estatística significante entre os grupos nos deslocamentos angular (p=0,674) e horizontal (p=0,856). Entretanto, no sentido cervico-oclusal, foi observada diferença entre os grupos (p=0,012) apontando maiores alterações para aqueles cuja inclusão foi realizada com o silicone (E3=0,047 e E2=0,044 cm)em relação ao gesso (E1 = 0,027 e C= 0,026cm). Os grupos com diferentes profundidades de palato não apresentaram diferença estatística significante entre si. Conclusão: esse estudo pôde concluir que o tipo de palato... / Statment of the problem: occlusal changes always occur during the complete dentures, however, the cervical-occlusal displacement of the tooth and its relationship with the plate depth has not yet been well clarified. Purpose: This study investigated the movement of the second molars in complete dentures processed with different palate depths and different materials for inclusion. Methods: Twenty-eight complete maxillary dentures were made on cast with shallow palate and twenty-eight on the cast with deep palate. These grafts were divided into four groups with 14 units according to the type of palate and the type of material for inclusion (gypsum or silicone). Points were marked on the distal face of second molars and in the model for measuring the displacement of the teeth. The vertical displacement, horizontal and angular was verified by the images of the prosthesis with the AutoCad program on two occasions: before inclusion and after deflasking (without the separation of the cast). The values were submitted to statistical Kolmogorov-Smirnov test and ANOVA with Tukey's and Fisher's post hoc test at 5% significance. Results: The results showed no statistically significant difference between groups in the angular displacement (p = 0674) and horizontal (p = 0856). However, the cervical-occlusal direction (vertical displacement), difference was observed between the groups (p = 0012) indicating major changes to those whose inclusion was performed with silicone (E3 = 0047 and E2 = 0044cm) on gypsum (E1 = 0027 and C = 0026cm). The groups with different depths of the palate showed no statistically significant difference between them. Conclusion: This study could conclude that the type of palate did not influence the movement of the second molars, as the method of inclusion of a significant influence on the vertical displacement of the teeth. Clinical... (Complete abstract click electronic access below)
104

Reação exotérmica e expansões de presa e térmica de revestimentos frente às técnicas de fundição convencional e rápida

Marchiori, André Vinícius [UNESP] 21 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-21Bitstream added on 2014-06-13T18:46:02Z : No. of bitstreams: 1 marchiori_av_dr_araca.pdf: 563641 bytes, checksum: e27a189557b1c36e9ca0161390fd734d (MD5) / Os protocolos estabelecidos numa técnica de fundição objetivam compensar a contração de solidificação da liga metálica e obter estruturas metálicas fundida com adequada adaptação cervical. A técnica de fundição rápida tem demonstrado ser uma alternativa, mas há dúvidas sobre como os revestimentos se expandem. Este estudo comparou as expansões de presa, térmica e total de três revestimentos odontológicos perante os procedimentos realizados em técnicas de fundição convencional e rápida. Na primeira parte desse estudo, determinaram-se as curvas das expansões resultantes da reação exotérmica de presa (n=5/revestimentoXtécnica), juntamente com as curvas de temperaturas que permitiram determinar o pico da exotermia e o intervalo médio requerido por cada revestimento para atingí-lo e; na segunda parte, aferiu-se a expansão térmica (n=3/revestimento). Para a análise estatística, utilizou-se o ANOVA e o Teste de Tukey (p<0,05). O maior valor médio de temperatura durante a presa foi determinado para o revestimento Micro Fine 1700 (88oC), que não diferiu estatisticamente do Heat Shock (80,3oC) e o menor, para o All Therm (67oC). O Micro Fine 1700 foi o que atingiu seu pico máximo de temperatura mais precocemente (5,8min), seguido pelo Heat Shock (16,4min) e o All Therm (18,8min), sendo todos diferentes entre si (p<0,05). Pôde-se constatar que os três revestimentos avaliados atingiram seus respectivos picos de temperatura num tempo menor ou igual a 20 minutos. Quanto à expansão de presa, para os revestimentos fosfatados foi muito menor no tempo de 20 minutos (tempo de espera para presa na técnica de fundição rápida) em comparação ao que se obteve com 60 minutos; o que não ocorreu, estatisticamente, para o revestimento cerâmico Micro Fine 1700. Só o revestimento cerâmico Micro Fine 1700 apresentou sua expansão de presa estabilizada aos 20 minutos. / The protocols established in casting techniques aimed to compensate the solidification contraction of metallic alloy and to get casting metallic structures with accurate marginal fit. The accelerated casting technique has demonstrated to be an alternative, but some doubts regarding investment expansion remains. This study compared the curves of temperatures resultant setting expansion and expansions of setting, thermal and total of three dental investments before the conventional and accelerated casting techniques. In the first part of this study, the curves of the resultant expansion of the setting exothermic reaction (n=5/investment) were determined, together with the curves of temperatures. Based on theses temperatures curves either the maximum exothermic setting reaction temperature, and the mean time interval required for each investment were calculated. In the second part, thermal expansion (n=3/investmentXtechnique) was analyzed. ANOVA and Tukey Test were used as a statistic analysis at 5% level of significance. Micro Fine 1700 investment showed the highest temperature values during the setting (88oC), and did not differ significantly from the Heat Shock (80.3oC) (p>.05). All Therm exhibited lower values (67oC) that differed from the two other investments (p<.05). Micro Fine 1700 reached the maximum exothermic setting reaction temperature first (5.8min), followed by Heat Shock (16.4min) and All Therm (18.8min) (p<.05). It can be evidenced that the three investments had reached their temperature peak until 20 minutes. The setting expansions of the phosphate bonded investments were very lower in the time of 20 minutes (wait time for setting in the accelerated casting technique) in comparison to 60 minutes. However, this difference did not occur to Micro Fine 1700 ceramic investment (p>.05). Analyzing thermal expansion, only Heat Shock showed statistic difference regarding technique factor.
105

Determinantes contextuais da necessidade de prótese total em idosos : uma análise multinível

Giordani, Jessye Melgarejo do Amaral January 2009 (has links)
Introdução: Tem sido demonstrado que fatores sociais, econômicos e do ambiente podem influenciar as condições de saúde bucal do indivíduo, principalmente para grupos vulneráveis como os idosos. O envelhecimento populacional desafia a habilidade de produzir políticas de saúde que respondam às necessidades das pessoas idosas. De acordo com o Inquérito Nacional de Saúde Bucal (SB Brasil), em 2003, cada idoso com idade entre 65 a 74 anos já havia perdido quase 26 dentes e mais da metade dessa população necessitava algum tipo de prótese. O objetivo do presente estudo foi avaliar a influência de aspectos sócio-demográficos e de serviços odontológicos contextuais na necessidade de prótese total em idosos. Metodologia: Este é um estudo epidemiológico transversal de base populacional de caráter multinível com dois níveis de análise, individual e contextual (municipal). Os dados do nível individual foram obtidos através de exames clínicos bucais (critérios da OMS) e entrevistas estruturadas conduzidos nos domicílios, a partir do banco de dados do SB Brasil e os do nível contextual a partir do Programa das Nações Unidas para o Desenvolvimento (2000) para os 250 municípios brasileiros participantes do inquérito. A população do estudo eram 5.349 indivíduos de 65 a 74 anos. O desfecho foi necessidade de prótese total em pelo menos uma das arcadas, constatada através de exame bucal em idosos desdentados, que não estavam usando prótese total no momento do exame. As exposições em nível contextual incluíam dados socioeconômicos, demográficos e de serviços odontológicos. Resultados: A prevalência de necessidade de prótese total para a faixa etária de 65 a 74 anos foi igual a 27,4%, (IC95%: 26,2-28,6). Após a análise ajustada, a chance de possuir necessidade de prótese total era menor nos residentes da Região Sul (OR 0,67; IC95%: 0,48-0,94); e maior nos municípios com menos de 3,6 anos de estudo (OR 1,57; IC95%: 1,09-2,27) quando comparados com aqueles residentes no Norte e com escolaridade maior que 6 anos. Quanto a variável de serviço odontológico, a chance de possuir necessidade de prótese total foi menor nos municípios onde havia mais de vinte mil habitantes para cada CD (OR 0,71; IC95%: 0,52-0,97) quando comparados com aqueles onde havia de 2 a 10 mil habitantes por CD. Conclusão: Aspectos contextuais apresentaram um efeito importante independentemente das variáveis individuais. Espera-se que o estudo tenha contribuído para que formuladores de políticas públicas de saúde bucal possam identificar municípios prioritários atuando com maior equidade visando a atenção integral e melhoria da qualidade de vida desta população. / Introduction: Where an individual lives and the characteristics of the social groups to which they belong may be an important determinant of its oral health, specially in elderly people. It poses challenges to health and social policy-makers due to the changing burden of chronic diseases and the marked inequalities in oral health status and access to dental care of this population. The National oral health survey (SBBrasil) showed that each people aged 65 to 74 years in 2003 had already lost 26 teeth and more than the half of this population needed some type of dental prosthesis. The objective of the present study was to assess the influence contextual variables on dentures need in older adults. Methodology: This is cross-sectional population based study in two levels: individual and contextual (town). Individual data was obtained by clinical examinations (WHO criteria) and structured interviews with 5,349 65-74- year-old individuals in 250 towns. Data sources from individual level was the SBBrasil and from contextual level was Program of United Nations for the Development. The outcome was denture need in at least one dental arch. This was assessed in edentulous elders not using dentures during the examination and interview. Contextual exposures included demographic, socioeconomic and dental care variables. Results: The prevalence of denture need was 27.4%, (CI95%: 26.2-28.6). After adjustment for individual level variables, the odds for denture need was higher in elders living in cities with low level of education and compared to those with high (OR 1.57; CI95%: 1.09-2.27) and lower in those with low per capita numbers of dental surgeons per inhabitant (OR 0.71; CI95%: 0.52-0.97). Conclusion: Regardless individual factors, contextual variables showed an independent effect on denture need in the population studied. The study may help policy makers to identify the cities in most need and reduce inequalities in dental care for this age group.
106

Comportamento sob fadiga de restaurações cerâmicas ultrafinas cimentadas adesivamente em preparos correspondentes aos dentes posteriores /

Abu-Izze, Fernanda de Oliveira. January 2017 (has links)
Orientador: Marco Antonio Bottino / Coorientadora: Lilian Costa Anami / Banca: Lafayette Nogueira Junior / Banca: Alberto Alvarenga de Oliveira / Resumo: A fim de investigar a vida em fadiga, modos de falha e distribuição de tensões de restaurações ultrafinas parciais, tipo tabletop, em diferentes cerâmicas, sessenta preparos padronizados foram confeccionados em resina epóxi G10 e foram cimentadas adesivamente restaurações cerâmicas de silicato de lítio reforçado com zircônia (ZLS, Vita Suprinity- Vita Zahnfabrik), ou restaurações de cerâmica híbrida (PIC, Vita Enamic- Vita Zahnfabrik), em 0,5 ou 1 mm de espessura. O mesmo protocolo de ciclagem foi aplicado para todos os espécimes, que consistiu em 5.000 ciclos a 200 N, seguidos de 450 N ciclos até a fratura dos espécimes ou a suspensão do teste após 1,5 x 106 ciclos. A carga axial foi realizada com uma freqüência de 4 Hz no equipamento Biocycle V2 (Biopdi, São Carlos, SP), com amostras imersas em água. A presença de falhas e/ou fraturas foi verificada a cada 2,5 x 105 ciclos e a análise de sobrevivência foi realizada com o número de ciclos em que cada espécime falhou. Os espécimes foram avaliados usando estereomicroscópio e microscopia eletrônica de varredura (MEV). Após a tabulação de dados, foram realizados Kaplan-Meier e Mantel-Cox (Teste Log Rank), seguindo de comparação múltipla aos pares, todos com nível de significância de 5% e análise de Weibull. Através da análise tridimensional de elementos finitos, a distribuição de tensões máximas principais (TMP) nas tabletop oclusais posteriores foram avaliados comparando diferentes tipos de substrato (G10, esmalte/dentina, esma... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To investigate the fatigue life, failure modes and stress distribution of partial ultrafine restorations for posterior teeth in different ceramics, sixty standard tabletop preparations in epoxy resin G10 received lithium silicate based zirconia reinforced (ZLS, Vita Suprinity- Vita Zahnfabrik), or hybrid ceramic (PIC, Vita Enamic- Vita Zahnfabrik), restorations in .5 or 1 mm thickness bonded using resin cement. The same cycling protocol was applied for all specimens that consisted of 5.000 cycles at 200 N followed by 450 N cycles until the specimens' fracture or the suspension of the test after 1.5 x 106 cycles. Axial load was carried out with a 4 Hz frequency in Biocycle V2 equipment (Biopdi, São Carlos, SP), with samples immersed in water. Presence of cracks and/or fractures was checked with every 2,5 x 105 cycles and the survival analysis was performed using the number of cycles in which each specimen failed. All specimens were evaluated using stereomicroscope and scanning electron microscopy (SEM). After data tabulation, Kaplan-Meier and Mantel-Cox (Log Rank test) analysis were performed, followed by multiple pairwise comparison, all with a significance level of 5%, and Weibull analysis. Through tridimensional finite element analysis, stresses distribution and maximum principal stresses in the posterior occlusal veneers were evaluated comparing different types of substrate (G10, enamel/dentin, enamel), thicknesses and ceramic materials. Zirconium-reinforced lithium silica... (Complete abstract click electronic access below) / Mestre
107

Avaliação da alteração linear de fundições com liga de níquel-cromo, obtidas por meio de dois revestimentos fosfatados de diferentes composições

Goshi, Carlos Magno [UNESP] 06 July 2000 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:25:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-07-06. Added 1 bitstream(s) on 2018-07-27T18:29:52Z : No. of bitstreams: 1 000126006.pdf: 1396022 bytes, checksum: 696526f54981b91d3365782e5f5af3bc (MD5) / Este trabalho avaliou a alteração linear de fundições com liga de níquel-cromo (Verabond II) obtidas com dois revestimentos fosfatados, sendo um com carga refratária à base de cerâmica granulada (Microfine 1700) que permite a introdução do anel após a presa diretamente em um forno pré-aquecido (750°C) e outro à base de cristobalita (Bellavest-T) de procedimento convencional. Quarenta padrões de cera (Bredent life-color-wachs) foram obtidos por meio de moldagem direta de uma matriz de aço inoxidável. Vinte padrões de cera foram incluídos com Microfine 1700 e vinte com Bellavest-T. Com o auxílio de um projetor de perfil com precisão de 0,001mm, mediu-se a distância entre dois pontos pré-estabelecidos na matriz. A mesma distância foi medida posteriormente na peça metálica reproduzida em liga de níquel-cromo, obtendo-se assim, as medidas das possíveis alterações dimensionais. Os resultados evidenciaram que a média da alteração linear das fundições com os dois revestimentos em relação à matriz, através do Test T de Student foi significante estatisticamente em nível de 5% para o Bellavest-T e em nível de 1% para o Microfine 1700. As conclusões foram as seguintes: a) os dois revestimentos não conseguiram compensar a contração da liga metálica e da cera no processo de fundição; b) a média das distâncias das fundições obtidas com revestimento Microfine 1700, apesar de apresentarem-se menores que a matriz e as fundições com o revestimento Bellavest-T, revelaram medidas mais constantes / This study evatuated the linear alteration of castings with NiCr alloy (Verabond II) obtained with two phosphate-bonded investments, one with granuled ceramic refractory load (Microfine 1700), which allows the introduction of the ring after setting directly in a pre-heated oven (750ºC); and another one, cristobalite-based (Bellavest-T) for conventional procedure. Forty wax patterns (Bredent life - color wachs, regular type II) were obtained through the direct molding of a stainless steel plate. Twenty wax patterns were invested in Microfine 1700 and twenty in Bellavest-T. A profile projector (0.001mm precision) measured the distance between 2 pre-established points in the matrix. The same distance was measured on the wax patterns and on the NiCr specimens produced, hereby obtaining the measure of the possible dimensional alterations of the materials. The results showed significance between the 2 investments (Bellavest-T, 5% and Microfine 1700, 1%) as compared to the matrix, through the Student's t test. The conclusions were: a) the two investments could not compensate the contraction of the alloy and wax in the casting process; b) the mean distance of the castings obtained with Microfine 1700, despite the fact of being smaller than the matrix and than the castings of Bellavest-T, showed more constant dimensions
108

Avaliação biomecânica de próteses unitárias sobre implantes de hexágono interno em maxila anterior com diferentes tipos de ancoragem óssea e comprimentos de implantes. Estudo pelo método dos elementos finitos 3-D. /

Cruz, Ronaldo Silva. January 2017 (has links)
Orientador: Fellippo Ramos Verri / Banca: Eduardo Piza Pellizzer / Banca: Joel Ferreira Santiago Junior / Resumo: Proposição: A proposta dessa pesquisa foi avaliar a distribuição de tensões em próteses unitárias implantossuportadas de hexágono interno (HI) na região maxilar anterior, variando a técnica de ancoragem óssea (Convencional (C), Bicorticalização (B) e Bicorticalização com elevação do assoalho nasal (BEAN) e as direções de carregamento (0°, 30° e 60°) por análise tridimensional (3D) de elementos finitos. Material e métodos: Três modelos tridimensionais foram simulados com ajuda dos programas Invesalius, Rhinoceros 3D 4.0 e SolidWorks 2011. Cada modelo possuía um bloco ósseo da região anterior do maxilar (osso tipo III) com 10m de altura padrão com um implante (4×8,5 mm (C), 4x10mm (B) e 4x11,5mm (BEAN), suportando uma coroa cimentada metal free. Os modelos foram processados pelos programas FEMAP v.11.0 e NEiNastran 11, utilizando uma força de 178 N em diferentes inclinações (0°, 30°, 60°). Os resultados foram plotados em mapas de tensão de von Mises (TvM), tensão máxima principal (TMxP), Microstrain (με) e Tendência de deslocamento (TD). Resultados: Análise de TvM mostrou aumento da concentração de tensão com o aumento da inclinação da força para os implantes, parafusos de fixação e abutments, com padrão similar de distribuição para os modelos testados. Sob análise de TMxP e με, o tecido ósseo apresentou maiores concentrações de tensões de tração sob cargas oblíquas (30° e 60°) ao redor do pescoço do implante na técnica convencional. Análise de deslocamento mostrou aumento... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: CRUZ, R. S. Biomechanical evaluation of unitary prostheses on implants of internal hexagon in anterior maxilla with different types of bone anchorage and implant lengths. Study by the finite element method 3- D. 2017. Dissertation (Masters in Dental Science, Biomaterials concentration area) - Faculty of Dentistry of Araçatuba, Paulista State University, Araçatuba 2017. Proposition: The purpose of this research was to evaluate the stress distribution of single crowns supported by internal hexagon (HI) implants in the anterior region of the maxilla, varying the bone anchoring technique (conventional (C), bicorticalization (B) and bicorticalization with nasal floor elevation (BNFE) at loading directions (0°, 30° and 60°) by three-dimensional (3D) finite elemento analysis. Material and methods: Three 3D models were designed with aid of Invesalius, Rhinoceros 3D 4.0 and SolidWorks 2011 software. Each model contained a bone block of the premaxillary área (type III bone) with 10m of standard height with one implant (4×8, 5mm (C), 4x10mm (B) and 4x11.5mm (BNFE)), supporting a cemented metal free crown. The models were processed by the FEMAP v.11.0 and NEiNastran 11 using load of 178 N at different inclinations (0°, 30°, 60°). Von Mises (TvM), maximum principal stress (TMxP), microstrain (με) and displacement maps (D) were plotted to results analysis. Results: Analysis of TvM showed increased of stress concentration with increasing load inclination for implants, fixation screws and abtments, with similar pattern of distribution for the tested models. Under TMxP and με analysis, bone tissue showed higher traction stress concentrations under oblique loads (30 ° and 60 °) around the implant neck for the conventional technique. Displacement analysis showed increase of inclination tendency similar for all models ... (Complete abstract electronic access below) / Mestre
109

Efeito de película de carbono tipo diamante nas propriedades mecânicas e de superfície da resina acrílica termopolimerizável

Silva, Pâmela Lopes Pedro da 29 April 2016 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-03-21T13:58:51Z No. of bitstreams: 1 arquivototal.pdf: 3342969 bytes, checksum: b7fd55c2ef970e109a7383e9f2aec090 (MD5) / Made available in DSpace on 2017-03-21T13:58:51Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 3342969 bytes, checksum: b7fd55c2ef970e109a7383e9f2aec090 (MD5) Previous issue date: 2016-04-29 / Introduction: The acrylic resin is used in dentistry for making dentures, orthodontic appliances and myo-relaxants splints; however, it has some limitations, such as low strength and high surface roughness. The diamond-like carbon (DLC) is a metastable form of amorphous carbon that can improve the resistance of various materials when applied as a film. Objective: To evaluate the effect of the DLC film application on the mechanical properties and surface of the acrylic resin thermally activated by power microwave (RAAT) (Vipi Wave). Materials and methods: Bodies of the test piece (flexural strength: 64 mm long x 10 mm wide x 3 mm; wear resistance: 4 mm diameter x 20 mm height, roughness: 10 mm diameter x 4 mm height) were obtained from the inclusion of replicas fiberglass flasks and polymerized according to the manufacturer. The deposition of films occurred by PECVD (Deposition Chemical Steam Assisted Plasma) with a thickness of 250 nm. They were divided into groups Gc (control) and Gt (treated) and underwent flexural strength test (n=18) in mechanical testing machine Instron (speed: 5 mm/min); wear resistance (n=18) biaxial Instron testing machine (load: 200 N, amplitude: 15 and frequency: 1,6 Hz) and analysis of the topography and surface roughness (Ra) by optical profilometry (n=18), with 5 objective measures of 20 X. the mean values were subjected to statistical tests of Mann-Whitney and t test to check the differences between the groups (p<0.05). Results: Gt showed higher roughness (0,108 ± 0,01 μm) than Gc (0,038 ± 0,01 μm), p<0,0001. There was no statistically significant difference (p=0,606) between Gt (103,3 MPa, IQ 97,67 ± 110,32) and Gc (105,3 MPa, IQ 98,95 ± 109,06) for resistance to flexion. There was no statistically significant difference between the groups in terms of straightness (Gt: 0,006 ± 0,0059 mm and Gc: 0,005 ± 0,0052 mm, p=0,774) and the depth of the indentations (Gt: 29,974 ± 8,69 μm and Gc : 28,169 ± 5,71 μm, p=0,610) after wear. Conclusion: The application of the DLC film on the surface of RAAT influenced the surface roughness having no effect on the flexural strength and wear. / Introdução: A resina acrílica é utilizada na Odontologia para confecção de próteses dentárias, aparelhos ortodônticos e placas mio-relaxantes; porém, apresenta algumas limitações, como baixa resistência e alta rugosidade de superfície. O carbono tipo diamante (DLC) é uma forma metaestável de carbono amorfo que pode melhorar a resistência de vários materiais quando aplicado como uma película. Objetivo: Avaliar o efeito da aplicação de película de DLC nas propriedades mecânicas e de superfície da resina acrílica ativada termicamente por energia de micro-ondas (RAAT) (Vipi Wave). Materiais e métodos: Corpos-de-prova (resistência à flexão: 64 mm comprimento x 10 mm largura x 3 mm altura; resistência ao desgaste: 4 mm diâmetro x 20 mm altura; rugosidade: 10 mm diâmetro x 4 mm altura) foram obtidos a partir da inclusão de réplicas em muflas de fibra de vidro e polimerizadas segundo o fabricante. A deposição dos filmes ocorreu por PECVD (Deposição Química a Vapor Assistida por Plasma), com espessura de 250 nm. Os mesmos foram divididos nos grupos Gc (controle) e Gt (tratado) e passaram por ensaio de resistência à flexão (n=18) em máquina de ensaios mecânicos Instron (velocidade: 5 mm/min); resistência ao desgaste (n=18) em máquina de ensaio biaxial Instron (carga: 200 N, amplitude: 15° e frequencia: 1,6 Hz) e análise da topografia e rugosidade superficiais (Ra) por meio de perfilometria ótica (n=18), com 5 medidas em objetiva de 20 X. Os valores médios foram submetidos aos testes estatísticos de Mann-Whitney e teste t para verificar as diferenças entre os grupos (p<0,05). Resultados: Gt apresentou maior rugosidade (0,108 ± 0,01 μm) do que Gc (0,038 ± 0,01 μm), com p<0,0001. Não foi encontrada diferença estatisticamente significante (p=0,606) entre Gt (103,3 MPa; IQ 97,67 ± 110,32) e Gc (105,3 MPa; IQ 98,95 ± 109,06) em relação à resistência à flexão. Não foi encontrada diferença estatisticamente significante entre os grupos quanto à retilineidade (Gt: 0,006 ± 0,0059 mm e Gc: 0,005 ± 0,0052 mm, p=0,774) e profundidade das edentações (Gt: 29,974 ± 8,69 μm e Gc: 28,169 ± 5,71 μm, p=0,610) após o desgaste. Conclusão: A aplicação da película de DLC na superfície da RAAT influenciou a rugosidade superficial não tendo efeito na resistência à flexão e ao desgaste.
110

Comportamento sob fadiga de restaurações cerâmicas ultrafinas cimentadas adesivamente em preparos correspondentes aos dentes posteriores / Fatigue behavior of ultrafine tabletop posterior ceramic restorations adhesively cemented

Abu-Izze, Fernanda de Oliveira 01 December 2017 (has links)
Submitted by FERNANDA DE OLIVEIRA ABU-IZZE null (fefeizze@hotmail.com) on 2018-03-12T22:56:56Z No. of bitstreams: 1 12.01.18 biblio correção final.pdf: 10328694 bytes, checksum: 640b2d0c989c903e0216bd6a154400e4 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-03-20T20:51:39Z (GMT) No. of bitstreams: 1 abu_izze_fo_me_sjc.pdf: 10328694 bytes, checksum: 640b2d0c989c903e0216bd6a154400e4 (MD5) / Made available in DSpace on 2018-03-20T20:51:39Z (GMT). No. of bitstreams: 1 abu_izze_fo_me_sjc.pdf: 10328694 bytes, checksum: 640b2d0c989c903e0216bd6a154400e4 (MD5) Previous issue date: 2017-12-01 / A fim de investigar a vida em fadiga, modos de falha e distribuição de tensões de restaurações ultrafinas parciais, tipo tabletop, em diferentes cerâmicas, sessenta preparos padronizados foram confeccionados em resina epóxi G10 e foram cimentadas adesivamente restaurações cerâmicas de silicato de lítio reforçado com zircônia (ZLS, Vita Suprinity- Vita Zahnfabrik), ou restaurações de cerâmica híbrida (PIC, Vita Enamic- Vita Zahnfabrik), em 0,5 ou 1 mm de espessura. O mesmo protocolo de ciclagem foi aplicado para todos os espécimes, que consistiu em 5.000 ciclos a 200 N, seguidos de 450 N ciclos até a fratura dos espécimes ou a suspensão do teste após 1,5 x 106 ciclos. A carga axial foi realizada com uma freqüência de 4 Hz no equipamento Biocycle V2 (Biopdi, São Carlos, SP), com amostras imersas em água. A presença de falhas e/ou fraturas foi verificada a cada 2,5 x 105 ciclos e a análise de sobrevivência foi realizada com o número de ciclos em que cada espécime falhou. Os espécimes foram avaliados usando estereomicroscópio e microscopia eletrônica de varredura (MEV). Após a tabulação de dados, foram realizados Kaplan-Meier e Mantel-Cox (Teste Log Rank), seguindo de comparação múltipla aos pares, todos com nível de significância de 5% e análise de Weibull. Através da análise tridimensional de elementos finitos, a distribuição de tensões máximas principais (TMP) nas tabletop oclusais posteriores foram avaliados comparando diferentes tipos de substrato (G10, esmalte/dentina, esmalte), espessuras e materiais cerâmicos. As restaurações de silicato de lítio reforçadas com zircônia com 0,5 mm de espessura (ZLS.5) apresentaram menor resistência à fadiga em comparação com restaurações cerâmicas híbridas de 1,0mm (PIC1), e ambas foram similares a outras restaurações (PIC.5 e ZLS1); X2 = 11,2; df = 3; p = 0,0107 <0,05). Os grupos ZLS apresentaram defeitos aleatórios que culminaram com a fratura, ao passo que os grupos PIC apresentaram defeitos que aumentaram com a fadiga mecânica após algum tempo sob ciclagem. As imagens do estereomicroscópio mostram falhas radiais observadas devido à translucidez do material, não houve danos causados pelo aplicador de carga. A distribuição de TMP foi semelhante para os diferentes tipos de substrato, mas o maior módulo de elasticidade mostrou uma concentração de tensão ligeiramente menor. É favorável o uso de PIC em espessura delgada, com resistência à fadiga semelhante à restaurações de ZLS mais espessas. / To investigate the fatigue life, failure modes and stress distribution of partial ultrafine restorations for posterior teeth in different ceramics, sixty standard tabletop preparations in epoxy resin G10 received lithium silicate based zirconia reinforced (ZLS, Vita Suprinity- Vita Zahnfabrik), or hybrid ceramic (PIC, Vita Enamic- Vita Zahnfabrik), restorations in .5 or 1 mm thickness bonded using resin cement. The same cycling protocol was applied for all specimens that consisted of 5.000 cycles at 200 N followed by 450 N cycles until the specimens’ fracture or the suspension of the test after 1.5 x 106 cycles. Axial load was carried out with a 4 Hz frequency in Biocycle V2 equipment (Biopdi, São Carlos, SP), with samples immersed in water. Presence of cracks and/or fractures was checked with every 2,5 x 105 cycles and the survival analysis was performed using the number of cycles in which each specimen failed. All specimens were evaluated using stereomicroscope and scanning electron microscopy (SEM). After data tabulation, Kaplan-Meier and Mantel-Cox (Log Rank test) analysis were performed, followed by multiple pairwise comparison, all with a significance level of 5%, and Weibull analysis. Through tridimensional finite element analysis, stresses distribution and maximum principal stresses in the posterior occlusal veneers were evaluated comparing different types of substrate (G10, enamel/dentin, enamel), thicknesses and ceramic materials. Zirconium-reinforced lithium silicate restorations with 0.5 mm thickness (ZLS.5) showed lower fatigue strength compared to 1.0 mm hybrid ceramic restorations (PIC1), and both were similar to other restorations (PIC.5 and ZLS1) (Log-Rank test, X2 = 11.2; df = 3; p = 0.0107<0.05). ZLS groups presented random defects that culminated with the fracture, whereas PIC groups presented defects that increased with the mechanical fatigue after some time under cycling. Stereomicroscope images show radial cracks observed due to the translucency of the material, there was no damage caused by applicator. TMP distribution was similar for the different substrate types, but the highest modulus of elasticity showed slightly lower stress concentration. PIC is favorable to be used in thin thickness with similar fatigue strength to thicker ZLS restorations.

Page generated in 0.0691 seconds