• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 701
  • 110
  • 21
  • 14
  • 14
  • 14
  • 14
  • 14
  • 12
  • 11
  • 9
  • 7
  • 7
  • 6
  • 2
  • Tagged with
  • 1013
  • 499
  • 276
  • 266
  • 237
  • 224
  • 216
  • 191
  • 179
  • 137
  • 126
  • 121
  • 114
  • 113
  • 111
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Resistência de união ao microcisalhamento de sistemas adesivos distintos em substrato dentinário normal e hipermineralizado artificialmente /

Kubo, Cinthia Sawamura. January 2013 (has links)
Orientador: Edson Alves de Campos / Banca: Marcelo Ferrarezi de Andrade / Banca: Cristina Magnani Felício / Resumo: O objetivo deste trabalho foi avaliar a resistência de união ao microcisalhamento de diferentes sistemas adesivos autocondicionantes de dois passos e passo único, com graus de acidez distintos, em substrato dentinário normal e hipermineralizado artificialmente. Sessenta e cinco (n = 65) incisivos bovinos hígidos foram selecionados, sendo cinqüenta e sete (n = 57) para o teste de resistência de união ao microcisalhamento e oito (n = 8) para a observação da interface adesiva em microscopia eletrônica de varredura (MEV). Os dentes tiveram suas raízes removidas com o auxílio de um motor elétrico e disco diamantado. As coroas tiveram sua superfície vestibular desgastada com o objetivo de expor a superfície dentinária plana, sendo os dentes divididos aleatoriamente em dois diferentes grupos, de acordo com o tipo de dentina: normal (N/ n = 28) e hipermineralizada artificialmente (H/ n = 29). O conjunto H recebeu tratamento para hipermineralização e um espécime foi selecionado aleatoriamente para observação em MEV para a confirmação do procedimento de hipermineralização. Cada coroa foi incluída em um cilindro de PVC com o auxílio de resina acrílica autopolimerizável. Cada grupo foi dividido em 4 subgrupos de acordo com o sistema adesivo autocondicionante empregado: Clearfil SE Bond (n=7) - suave de dois passos, Adhese (n = 7) - moderado de dois passos, Adper Easy One (n = 7) - suave de passo único, Optibond All in One (n = 7) - moderado de passo único. Sobre essa superfície foram inseridos e fotopolimerizados cilindros de resina composta (FiltekTM Z350 XT - 3M ESPE). Após período de armazenagem de 24 horas em ambiente úmido a 37°C (± 1°C), foram realizados os testes de microcisalhamento em máquina de ensaios mecânicos com velocidade de 0,5 mm/min até à fratura dos espécimes. A fim de verificar a presença de interface e/ou a aparência de tags de resina, um... / Abstract: The aim of this study was to evaluate the microshear bond strength of different self-etching two-step and all-in-one adhesive systems, with different acid concentrations to sound and artificially hypermineralized dentin. Sixty-five (n = 65) healthy bovine incisors were selected, fifty-seven (n = 57) to test the microshear bond strength and eight (n = 8) to observe the presence of adhesive interface with scanning electron microscopy (SEM). Teeth have roots removed using an electric motor and diamond disc. Vestibular surface were ground flat to expose a flat dentin surface, the teeth were divided randomly into two different groups according the type of dentin: sound (N / n = 28) or artificially hypermineralized (H / n = 29). The set H received hypermineralizing treatment and a specimen was selected randomly to observe the procedure with SEM. Each crown was included in a PVC cylinder using acrylic resin. Each group was divided into 4 subgroups according to dentin adhesive systems: Clearfil SE Bond (n = 7) - mild two steps, AdheSE (n = 7) - moderate two steps, Adper Easy One (n = 7) - mild all-in-one, Optibond All in One (n = 7) - moderate all-in-one. Then were inserted and cured resin cylinders (Filtek Z350 XT - 3M ESPE) at the surface. After 24 hours storage at 37 ° C (± 1°C), for humid environment, microshear was taked using mechanical testing machine with 0.5 mm/min speed until fracture of the specimens. For analysis the presence of an interface and/or appearance of resin tags, a specimen of each group was prepare for evaluating the adhesive interface with SEM. Bond strengths data were subjected to ANOVA and Bonferroni (p<0.05) test. The bond strength values were Clearfil = 15.65 ± 6.18, AdheSE = 14.71 ± 10.36, Easy One = 21.92 ± 6.40, OptiBond = 28.43 ± 6.55 to sound dentin and Clearfil = 20.96 ± 8.06, AdheSE = 17.23 ± 5.16, Easy One = 31.79 ± 8.31, OptiBond = 23.29 ± 3.66 to... / Mestre
282

Citotoxidade direta e transdentinária de sistemas adesivos com diferentes graus de hidrofilia sobre células odontoblastóides

Bianchi, Luciana [UNESP] 19 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-19Bitstream added on 2014-06-13T19:56:38Z : No. of bitstreams: 1 bianchi_l_me_arafo.pdf: 1440402 bytes, checksum: e46b54f688f969e58ca558c0a1176228 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo geral desse trabalho, dividido em dois experimentos (capítulos 1 e 2), foi avaliar a citotoxicidade de sistemas adesivos experimentais (SAEs), com diferentes graus de hidrofilia, e do etanol como solução de solvatação da dentina, sobre células odontoblastóides. No capítulo 1, discos de papel filtro esterilizados foram impregnados com 10 μL de cada SAE (n=22): R1, R2, R3, R4 e R5 (em ordem crescente de hidrofilia), seguido de fotoativação. Os discos foram individualmente imersos em meio de cultura DMEM para obtenção de extratos (DMEM + componentes liberados dos SAEs), os quais foram posteriormente aplicados sobre células MDPC-­‐23 em cultura. Discos não impregnados (R0) serviram como controle. Foram avaliados o metabolismo celular (teste de MTT), a expressão de proteína total (PT) e a atividade de fosfatase alcalina (FA), além do tipo de morte celular (citometria de fluxo) e grau de conversão monomérica (FTIR) dos SAEs. Os dados de cada variável resposta do estudo foram analisados por testes de Kruskal-­‐Wallis e Mann-­‐Whitney (α=0,05). Considerando R0 como 100%, foi observada redução do metabolismo celular de 36,4%, 3,1%, 0,2%, 21,5% e 65,7%, respectivamente para R1, R2, R3, R4 e R5. Apenas R1 e R5 diferiram estatisticamente do controle. Para PT, R1, R4 e R5 tiveram expressão estatisticamente inferior ao controle, enquanto que a atividade de FA foi significativamente reduzida por R1 e R5. Esses mesmos SAEs juntamente com R4 induziram as maiores porcentagens de morte... / The overall aim of this study, divided into two experiments, was to evaluate the cytotoxicity of experimental adhesive systems (EAS) with different hydrophilicity, and ethanol as a dentin solvation solution, on odontoblast-­‐like cells. In the first experiment, sterilized filter paper discs were impregnated with 10 μL of each EAS: R1, R2, R3, R4 and R5 (in increasing rank of hydrophilicity), followed by light activation. The paper discs were individually immersed in DMEM culture medium for obtaining the extracts (DMEM + released components of EAS), which were applied on MDPC-­‐23 cells in culture. Non-­‐impregnated paper discs (R0) were used as control. Cell metabolism (MTT assay), total protein expression (TP) and alkaline phosphatase activity (ALP) were assessed, in addition to the type of cell death (flow cytometry) and the degree of monomer conversion (FTIR). Data for each response variable were submitted to Kruskal-­‐Wallis and Mann-­‐Whitney tests (α=0.05). Compared to the control (100%), cell metabolism was decreased by 36.4%, 3.1%, 0.2%, 21.5% and 65.7% for R1, R2, R3, R4 and R5, respectively. However, only R1 and R5 differed from the control. R1, R4 and R5 decreased the expression of TP compared to the control, whereas only R1 and R5 significantly reduced the activity of ALP. The later EAS plus R4 caused the highest percentages of cell death by necrosis. A higher percentage of monomer conversion was detected as a function of the hydrophilicity. According to the experimental conditions, it could be... (Complete abstract click electronic access below)
283

Avaliação da resistência de união em dentina de um adesivo de frasco único quando utilizado diferentes fontes de ativação

Kreidler, Martín Antúnez de Mayolo [UNESP] 14 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-14Bitstream added on 2014-06-13T20:51:31Z : No. of bitstreams: 1 kreidler_mam_me_arafo.pdf: 1061515 bytes, checksum: 8631de69ed2363b4ba75419b58ee0e3b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito deste estudo foi avaliar através do teste de microtração e da análise do padrão de fratura, o efeito da luz halógena e LED, na ativação de um adesivo de frasco único. Superfícies dentinárias planas foram criadas em 16 dentes terceiros molares hígidos. Os dentes foram aleatoriamente divididos em 4 grupos: Grupo G1 - Aparelho de luz halógena - KM-200R®; Grupo G2 - Aparelho LED - Ultraled®; Grupo G3 - Aparelho LED - UltraLume®LED5 e Grupo G4 - Aparelho LED - Biolux Single V®. O procedimento restaurador foi realizado utilizando o adesivo Single Bond® e a resina composta InTen-S®. Após as restaurações, os dentes foram armazenados em água destilada e estufa a 37ºC por 24h. A seguir, os mesmos foram cortados, resultando em espécimes com área de aproximadamente 1 mm2, que foram selecionados e submetidos ao teste de microtração para posterior observação do padrão de fratura no microscópio digital. Os resultados, submetidos a análise estatística mostram que o grupo G2 teve média de resistência de união significativamente menor que os demais grupos, que foram semelhantes entre si. Quanto ao tipo de fratura, houve diferença significativa entre os grupos G1 e G2 e entre os grupos G2 e G4. Entre os outros grupos não houve evidência de diferenças significativas. As falhas de união foram predominantemente do tipo adesivas. Conclui-se que os aparelhos LEDs de segunda e terceira geração utilizados nesta pesquisa podem ser utilizados como uma alternativa viável à luz halógena. / The purpose of this study was to evaluate the effect of halogen light and LED on dentin tensile bond strength and fracture mode analysis. Flat dentin surfaces were created on 16 intact human third molars. The teeth were randomly divided in 4 groups: Group G1 - halogen - KM -200R®; Group G2 - LED - Ultraled®; Group G3 - LED - UltraLume LED5® and Group G4 - LED - Biolux Single V®. The restoration procedure used Single Bond® adhesive and InTen-S® composite resin. The teeth were placed in distilled water and stored at 37ºC for 24 hours. Then, they were cut on serial sections to obtain 1 mm2 area. The samples were submitted to micro tensile test and after words, the fractures were analysed with a digital microscope. The statistical analysis showed that all in all groups, except Group G2, which had a significant smaller tensile bond strength ratio. The fracture mode analysis showed that there were significant difference when comparing groups G1 / G2, and G2 / G4. There is no evidence of relevant differences among the other groups. Adhesive fracture was the most common fracture mode. As a conclusion, second and third LED generation used in this research could be use as an alternative to the conventional halogen lamp. Keyword: Dentin-bonding agents; tensile strength.
284

Resistência de união ao microcisalhamento de sistemas adesivos distintos em substrato dentinário normal e hipermineralizado artificialmente

Kubo, Cinthia Sawamura [UNESP] 23 September 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-09-23Bitstream added on 2014-06-13T19:51:21Z : No. of bitstreams: 1 000735144.pdf: 2073236 bytes, checksum: 613ef7d6b680f1fe13f367e82696ff5c (MD5) / O objetivo deste trabalho foi avaliar a resistência de união ao microcisalhamento de diferentes sistemas adesivos autocondicionantes de dois passos e passo único, com graus de acidez distintos, em substrato dentinário normal e hipermineralizado artificialmente. Sessenta e cinco (n = 65) incisivos bovinos hígidos foram selecionados, sendo cinqüenta e sete (n = 57) para o teste de resistência de união ao microcisalhamento e oito (n = 8) para a observação da interface adesiva em microscopia eletrônica de varredura (MEV). Os dentes tiveram suas raízes removidas com o auxílio de um motor elétrico e disco diamantado. As coroas tiveram sua superfície vestibular desgastada com o objetivo de expor a superfície dentinária plana, sendo os dentes divididos aleatoriamente em dois diferentes grupos, de acordo com o tipo de dentina: normal (N/ n = 28) e hipermineralizada artificialmente (H/ n = 29). O conjunto H recebeu tratamento para hipermineralização e um espécime foi selecionado aleatoriamente para observação em MEV para a confirmação do procedimento de hipermineralização. Cada coroa foi incluída em um cilindro de PVC com o auxílio de resina acrílica autopolimerizável. Cada grupo foi dividido em 4 subgrupos de acordo com o sistema adesivo autocondicionante empregado: Clearfil SE Bond (n=7) – suave de dois passos, Adhese (n = 7) – moderado de dois passos, Adper Easy One (n = 7) – suave de passo único, Optibond All in One (n = 7) – moderado de passo único. Sobre essa superfície foram inseridos e fotopolimerizados cilindros de resina composta (FiltekTM Z350 XT - 3M ESPE). Após período de armazenagem de 24 horas em ambiente úmido a 37°C (± 1°C), foram realizados os testes de microcisalhamento em máquina de ensaios mecânicos com velocidade de 0,5 mm/min até à fratura dos espécimes. A fim de verificar a presença de interface e/ou a aparência de tags de resina, um... / The aim of this study was to evaluate the microshear bond strength of different self-etching two-step and all-in-one adhesive systems, with different acid concentrations to sound and artificially hypermineralized dentin. Sixty-five (n = 65) healthy bovine incisors were selected, fifty-seven (n = 57) to test the microshear bond strength and eight (n = 8) to observe the presence of adhesive interface with scanning electron microscopy (SEM). Teeth have roots removed using an electric motor and diamond disc. Vestibular surface were ground flat to expose a flat dentin surface, the teeth were divided randomly into two different groups according the type of dentin: sound (N / n = 28) or artificially hypermineralized (H / n = 29). The set H received hypermineralizing treatment and a specimen was selected randomly to observe the procedure with SEM. Each crown was included in a PVC cylinder using acrylic resin. Each group was divided into 4 subgroups according to dentin adhesive systems: Clearfil SE Bond (n = 7) - mild two steps, AdheSE (n = 7) - moderate two steps, Adper Easy One (n = 7) - mild all-in-one, Optibond All in One (n = 7) - moderate all-in-one. Then were inserted and cured resin cylinders (Filtek Z350 XT - 3M ESPE) at the surface. After 24 hours storage at 37 ° C (± 1°C), for humid environment, microshear was taked using mechanical testing machine with 0.5 mm/min speed until fracture of the specimens. For analysis the presence of an interface and/or appearance of resin tags, a specimen of each group was prepare for evaluating the adhesive interface with SEM. Bond strengths data were subjected to ANOVA and Bonferroni (p<0.05) test. The bond strength values were Clearfil = 15.65 ± 6.18, AdheSE = 14.71 ± 10.36, Easy One = 21.92 ± 6.40, OptiBond = 28.43 ± 6.55 to sound dentin and Clearfil = 20.96 ± 8.06, AdheSE = 17.23 ± 5.16, Easy One = 31.79 ± 8.31, OptiBond = 23.29 ± 3.66 to...
285

Influência de soluções de armazenamento, métodos de esterilização e suas associações sobre a microdureza dentinária radicular em dentes humanos: estudo in vitro

Aivazoglou, Marcos Uyeda [UNESP] 20 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-20Bitstream added on 2014-06-13T20:52:11Z : No. of bitstreams: 1 aivazoglou_mu_me_sjc.pdf: 824575 bytes, checksum: 4e12578b1bcd3f46a9498806051844fd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a ação das soluções de armazenamento: água destilada (G1), solução de timol a 0,05%(G2), formalina a 10%(G3), e hipoclorito de sódio a 1%(G4), bem como os métodos de esterilização por autoclave (A) e radiação gama (B), e as associações dos dois fatores, sobre a microdureza da dentina radicular de terceiros molares extraídos. Os dados obtidos foram submetidos aos testes t de Student, ANOVA a 2 e 3 fatores, e teste de Tukey, todos com α=0,05. Quanto ao armazenamento, o G1(nos dois períodos avaliados) foi o único grupo que não alterou significantemente a microdureza, sendo seguido pelos grupos G2 e G3 (7 dias), G2 e G3 (28 dias), e G4 (7 e 28 dias), tendo estes dois últimos subgrupos apresentado as maiores perdas de microdureza. Na análise da esterilização isoladamente, não houve diferença significante para os 2 métodos quando comparadas as microdurezas iniciais e após a esterilização (autoclave: p=0,144; raios gama: p=0,827), apesar da esterilização por autoclave ter induzido diferenças significantes no grupo armazenado por 28 dias em água destilada. Entretanto, estudada a interação de todos os fatores, encontraram-se diferenças significantes quanto à solução empregada, método de esterilização e interações entre eles (p<0,05). Com base nos dados analisados pôde-se concluir que o armazenamento em água destilada não alterou a microdureza dentinária radicular, e sua associação à esterilização por radiação gama foi o melhor método para o armazenamento e esterilização de dentes, no que diz respeito às influências sobre a variável estudada, sendo indicados para dentes extraídos a serem utilizados em pesquisa. / The aim of this study was to evaluate the effect of storage solutions: distilled water (G1), 0.05% thymol solution (G2), 10% formalin (G3), and 1% sodium hypochlorite (G4); sterilization methods- steam autoclaving (A) and gamma irradiation (B)- and the associations between the two factors on the root dentin microhardness of extracted human third molars. Data were subjected to student’s t test for dependent samples, Two and Three-way ANOVA, and Tukey’s test (α = 0.05 for all tests). Regarding storage, only the G1 (in both periods) did not alter the dentin microhardnes significantly. In the analysis of sterilization methods, there were significant differences on the solution employed, storage time and sterilization method (p <0.05). Based on the results, it was concluded that the storage in distilled water did not change the root dentin microhardness, and association of this storage solution with sterilization by Gamma radiation did not produce alterations by means of the studied variable, thus consisting in the best methods regarding storage and sterilization of teeth to be used in research.
286

Análise in vitro da progressão de lesões de erosão em dentina após irradiação com laser de Nd:YAG e flúor através de tomografia por coerência óptica (OCT) / In vitro analysis of erosion progression in dentine lesions after laser irradiation of Nd:YAG and fluoride using optical coherence tomogragry (OCT)

MORAES, MARCIA C.D. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:42Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:00Z (GMT). No. of bitstreams: 1 17899.pdf: 5286933 bytes, checksum: dc9e220ef9d434b0d99604645076246a (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP; Faculdade de Odontologia, Universidade de São Paulo, São Paulo
287

Irradiacao de dentina cervical radicular com laser de Nd:YAG - Estudo in vitro e microscopia eletronica de varredura

BRITTO, CYNTHIA T.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:43Z (GMT). No. of bitstreams: 1 10194.pdf: 3183980 bytes, checksum: 06ee82fcc1fa34f2eae8829e2a7b8c03 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo
288

Análise da influência do calor residual na adesão dentinária após a irradiação com o laser de Er, Cr:YSGG

BARROS, JULIANA de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:28Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:37Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP; Faculdade de Odontologia, Universidade de Sao Paulo, Sao Paulo
289

Influência da irradiação do laser de Er:YAG na adesão da resina composta à dentina, após o clareamento dental com o laser de diodo

SERIKAKU, ANA L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:56Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:58Z (GMT). No. of bitstreams: 1 12802.pdf: 3001679 bytes, checksum: ffc3fbe0d67bf135d7db2b397308dc14 (MD5) / Dissertação (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de São Paulo, São Paulo
290

Estudo in vitro da alteracao da temperatura durante a aplicacao do Er:YAG laser intracanal

BRANDAO, REDSON V. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:04Z (GMT). No. of bitstreams: 1 07501.pdf: 4082320 bytes, checksum: 50a98dfc3e7126d5b1c09ad2c2bcd7df (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo

Page generated in 0.0756 seconds