• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 701
  • 110
  • 21
  • 14
  • 14
  • 14
  • 14
  • 14
  • 12
  • 11
  • 9
  • 7
  • 7
  • 6
  • 2
  • Tagged with
  • 1013
  • 499
  • 276
  • 266
  • 237
  • 224
  • 216
  • 191
  • 179
  • 137
  • 126
  • 121
  • 114
  • 113
  • 111
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Molhabilidade da dentina erodida sob ação de dentifrícios dessensibilizantes / Eroded dentin wettability under effect of desensitizing dentifrices

Raísa Castelo Bessa Nogueira 10 January 2017 (has links)
Os dentifrícios dessensibilizantes que obliteram os túbulos dentinários atuam por meio do depósito de minerais na superfície e nos túbulos da dentina, o que pode provocar alteração nas propriedades de adesão da superfície dental, como a molhabilidade do substrato pelo adesivo. Assim, o objetivo do estudo foi avaliar o efeito do dentifrício dessensibilizante sobre a molhabilidade da dentina erodida e analisar a topografia da dentina tratada por meio da Microscopia Confocal a Laser antes e depois do condicionamento ácido. Oitenta fragmentos de dentina bovina (7mm X 7mm), foram planificados, polidos e imersos em 10mL de ácido cítrico (pH = 3,2) durante 2 horas. Os espécimes foram divididos aleatoriamente de acordo com o dentifrício utilizado: dentifrício sem ação dessensibilizante (fluoreto de sódio) - controle (D1); arginina 8% e carbonato de cálcio - Colgate® Sensitive Pró-Alívio (D2); fosfosilicato de cálcio e sódio - Novamin®-Sensodyne® Repair & Protect (D3); acetato de estrôncio 8% - Sensodyne® Rápido Alívio (D4) e tempo de simulação de escovação de 7 dias (T1) e 21 dias (T2). Os corpos de prova foram submetidos a ciclos de escovação mecânica de 3 e 9 minutos, equivalente a 7 e 21 dias de escovação, 3 vezes ao dia, respectivamente, com escova macia. O condicionamento da dentina foi realizado com ácido fosfórico 37% por 15 segundos. Uma gota do sistema adesivo Single Bond Universal (3M) foi depositada na superfície de cada espécime e o ângulo de contato entre a superfície da dentina e o sistema adesivo foi medido utilizando um Goniômetro. Doze novos corpos de prova (n = 3) foram escovados nas mesmas condições experimentais por 21 dias e a topografia da dentina foi observada com Microscópio Confocal a Laser, antes e após o condicionamento ácido das superfícies escovadas. Os dados foram submetidos a Análise de Variância (ANOVA) a dois fatores (p>0,05). Não houve diferença entre o ângulo de contato obtido na dentina erodida submetida à escovação com os dentifrícios dessensibilizantes. Os resultados demonstraram que o fator tempo foi estatisticamente significante (p<0,05) sob a variável molhabilidade, enquanto o fator tratamento isoladamente bem como a sua interação com o tempo não tiveram efeito estatisticamente significante na variável do estudo (p&ge; .05). Portanto, conclui-se que uso de dentifrícios dessensibilizantes não interfere na molhabilidade da dentina erodida após 7 e 21 dias de escovação e o fator tempo de escovação, isoladamente, determinou redução da molhabilidade após 21 dias. / Desensitizing dentifrices that occlude dentinal tubules act by mineral deposition on the surface and inside dentinal tubules, which may cause may cause changes in the adhesion properties of the dental surface, such as the substrate wettability by adhesive systems. The aim of this study was to evaluate the effect of desensitizing dentifrices on the wettability and topographic analysis of eroded dentin. Eighty fragments of bovine dentin (7mmX7mm) were planned, polished and immersed in 10mL of 0,3% citric acid (pH=3,2) during 2 hours. The specimens were randomly divided in eight groups according to the desensitizing agent: sodium fluoride - control (C); 8% arginine and calcium carbonate (DA1); sodium calcium phosphosilicate (DA2); and strontium acetate (DA3) and brushing time simulation (7 and 21 days). The specimens were submitted to mechanic brushing cycles of 3 and 9 minutes, equivalents to 7 and 21 days of brushing, three times a day, with a soft brush. Dentin etch with 37% phosphoric acid for 15 seconds and then washed for 30 seconds. A drop of 10&micro;L adhesive system Single Bond Universal (3M ESPE) were placed on each specimen surface and the contact angle between dentin surface and adhesive system were measured using a Goniometer. Twelve other specimens (n=3) were brushed under the same experimental conditions for 21 days and the dentin topography was observed with Confocal Laser Scanning Microscope, before and after etch of the brushed dentin surfaces. Data were summited to 2-way ANOVA analysis and the results presented that the time factor had a statistically significant effect (p <0.05) on the wettability variable, while the treatment factor alone and the interaction between treatment and time factors, had no statistically significant effect on the variable study (p &ge; 0.05). Therefore, the use of desensitizing dentifrices did not interfere with the wettability of etched dentin after 7 and 21 days of brushing. Brushing time factor, alone, determined reduction of wettability after 21 days.
242

Efeito de um gel à base de Cranberry sobre a dentina submetida à erosão dentária / Effect of Cranberrybased gel subjected to dentin of dental erosion

Joana Regina Dokko 25 October 2013 (has links)
Esta pesquisa teve como objetivo estudar in situ o efeito protetor de um gel à base de Cranberry aplicado sobre a dentina submetida à erosão. Este estudo duplo cego e cruzado constou de 2 fases com duração de 5 dias cada. Para tal, 10 voluntários utilizaram2 aparelhos palatinos (um em cada fase) com 4 blocos de dentina bovina divididos em 2 grupos. Na primeira fase estiveram presentes os grupos: G1 Ação da bebida ácida (Coca-cola®) sobre a dentina bovina sem nenhum tipo de tratamento prévio; G2 - Ação da bebida ácida sobre a dentina tratada com gel à base de Cranberry e na segunda fase foi testado os grupos: G3 Ação da bebida sobre a dentina tratada com gel de aplicação tópica sem nenhum princípio ativo; G4 - Ação da bebida ácida sobre a dentina tratada previamente com gel de Clorexidina. Cada aparelho foi imerso na bebida ácida, 3x/dia, durante 5 minutos por 5 dias. A porcentagem de perda de microdureza de superfície (%PDS) e a perfilometria foram as variáveis utilizadas para quantificar as alterações dadentina. A comparação dos grupos por meio da análise de variância de medidas repetidas seguido do teste de Fisher mostrou haver diferenças estatisticamente significativas entre os grupos para o desgaste (G1: 4,98 &#x3BC;m ± 1,36; G2: 3,29 &#x3BC;m ± 1,16; G3: 4,38 &#x3BC;m ± 1,19; G4: 3,32 &#x3BC;m ± 1,55) e não apresentou diferenças entre eles na %PDS (G1: 28,12 ± 5,71; G2: 24,92 ± 5,38; G3: 25,74 ± 9,15; G4: 29,83 ± 8,63).Assim, quanto ao desgaste não houve diferença estatisticamente significativa entre os grupos controle e placebo, também não houve uma diferença entre os grupos Cranberry e clorexidina. Porém, os grupos Cranberry e clorexidina apresentaram menores valores de desgaste em relação aos grupos Placebo e Controle (sem gel), sendo esta diferença estatisticamente significativa. Os resultados obtidos nesse estudo sugerem uma significativa eficácia dos géis ativos à base de Cranberry e de Clorexidina na prevenção do desgaste da dentina submetida à erosão dentária. / The aim of this study is to evaluate the in situ effect of a Cranberry gel over dentine submitted to a erosive challenge. This crossover doble-blinded study was performed in 2 phases of 5 days each. For that purpose, 10 volunteers wore 2 palatal devices (1 for each phase) with 4 dentin specimens divided into 2 groups: First Phase: G1 - Erosive challenge (Coca-cola®) over dentine without any previous treatment; G2 - Erosive challenge over dentine previously treated with Cranberry gel; and Second Phase: G3 - Erosive challenge over dentine previously treated with a gel withot any active principle; G4 - Erosive challenge over dentine previously treated with Clorexidine gel. Each device was immersed into the acid beverage, 3 times daily for 5 minutes during 5 days. The surface microhardness change percentage (%SMC) and profilometry were be used to quantify the dentin alteratons. The comparison between groups by repeated measures analysis of variance followed by Fisher\'s test showed statistically significant differences between groups for wear (G1: 4.98 ± 1.36 mM, G2: 3.29 ± 1 mM, 16, G3: 4.38 ± 1.19 mM; G4: 3.32 ± 1.55 mM) and showed no differences b in% SMH (G1: 28.12 ± 5.71; G2: 24.92 ± 5.38, G3: 25.74 ± 9.15; G4: 29,83 ± 8,63). So as to wear there was no statistically significant difference between the placebo and control groups.There was also no difference between Cranberry andchlorhexidine groups. However, Cranberry and chlorhexidine groups presented lower wear compared to placebo and control groups (without gel), and this difference was statistically significant. The results of this study suggest a significant efficacy of active gels based Cranberry and chlorhexidine in preventing wear of dentin subjected to dental erosion.
243

Resistência de união à dentina de sistemas adesivos irradiados com laser de diodo: estudo in vitro / Bond strength to dentin with adhesive systems irradiated with diode laser: in vitro study

Maenosono, Rafael Massunari 26 March 2013 (has links)
A irradiação LASER sobre os sistemas adesivos aplicados em dentina, antes de sua fotoativação, tem sido proposta para aumentar a resistência de união de restaurações adesivas. O objetivo foi avaliar o efeito da irradiação com LASER de Diodo (&#x3BB; = 970nm) sobre diferentes sistemas adesivos na resistência de união imediata à dentina. Oitenta molares humanos hígidos foram aleatoriamente distribuídos em 8 grupos (n=10) de acordo com o sistema adesivo: MP (Adper&#x2122; ScotchBond Multi-Purpose Plus - convencional não simplificado), SB (Adper&#x2122; SingleBond 2 - convencional simplificado), CSE (Clearfil&#x2122; SE Bond - autocondicionante não simplificado), EO (Adper&#x2122; EasyOne - autocondicionante simplificado); e respectivos grupos irradiados com LASER de Diodo (SiroLaser, Sirona Dental). Para avaliar a resistência de união foi realizado teste de microtração, obtendo-se valores em MPa, posteriormente analisados através de ANOVA a 2 critérios, seguido de Tukey para comparações individuais e múltiplos testes t (p<0,05) para comparações entre CONTROLE e LASER do mesmo sistema adesivo. Os valores de resistência de união ± desvio padrão para os grupos sem e com irradiação com LASER foram respectivamente: MP (40,10±10,95 / 35,82±7,17), SB (33,49±6,77 / 43,69±8,15), CSE (43,71±15,71 / 37,95±7,66) e EO (19,67±5,86 / 29,87±6,98). A irradiação com LASER de Diodo provocou um aumento da resistência de união obtida pelos sistemas adesivos SB e EO, mostrando-se uma técnica promissora na obtenção de uma adesão mais efetiva de sistemas adesivos simplificados ao substrato dentinário. / LASER irradiation on adhesive systems before it`s activation has been proposed to increase bond strength of composite restorations to dentin. The objective was to evaluate the effect of Diode LASER irradiation (&#x3BB; = 970nm) on different adhesive systems on immediate bond strength to dentin. Eighty healthy human molars were randomly distributed in 8 groups (n=10) according to the adhesive system: MP (Adper&#x2122; ScotchBond Multi-Purpose Plus, non simplified etch and rinse), SB (Adper&#x2122; SingleBond 2 simplified etch and rinse), CSE (Clearfil&#x2122;SE Bond non simplified self-etch), EO (Adper&#x2122; EasyOne simplified self-etch); and respective groups irradiated with Diode LASER (SiroLaser, Sirona Dental). Microtensile test was performed obtaining bond strength values in MPa whice were analyzed by two way ANOVA, followed by Tukey for individual comparisons and multiple t test (p<0.05) for evaluation of CONTROL and LASER groups with the same adhesive systems. Bond strength values ± standard deviation for groups without and with LASER irradiation were respectively: MP (40.10±10.95 / 35.82±7.17), SB (33.49±6.77 / 43.69±8.15), CSE (43.71±15.71 / 37.95±7.66) and EO (19.67±5.86 / 29.87±6.98). Irradiation with Diode LASER resulted in an increase of SB and EO bond strength values, being considered a promising technic to obtain an improved adhesion of simplified adhesive systems to dentin substrate.
244

Efeito da variação da densidade de energia da ponta e da frequência na resistência de união à dentina de sistema adesivo convencional irradiado com diferentes laseres de alta potência / Variation of the effect of the energy density of the fiber tip and frequency in bond strength to irradiated conventional dentin bonding system with different high-power LASERs

Cardia, Guilherme Saintive 15 September 2015 (has links)
O objetivo deste estudo foi comparar o efeito da irradiação de dois tipos de laser (laser Nd:YAG e de Diodo) sobre um sistema adesivo convencional de três passos, utilizando três diferentes densidades de energia da ponta, na resistência de união imediata e após 1 ano. Foram selecionados 70 dentes humanos e cada um teve sua coroa seccionada, expondo a superfície da dentina necessária para os procedimentos adesivos e restauradores. Após o preparo dos dentes, os mesmos foram aleatoriamente subdivididos em 7 grupos (n=10), sendo 6 grupos-teste e um grupo controle. Na sequência, foi aplicado o sistema adesivo Scotchbond&#x2122; Multi- Purpose Plus e, antes de sua fotoativação, em três grupos, o laser Nd:YAG foi utilizado com 3 diferentes densidades de energia (1 509,55 J/cm2, 2 254,77 J/cm2 e 3 127,38 J/cm2), o mesmo procedimento com as mesmas densidades foi realizado nos três demais grupos com o laser de Diodo. Após a irradiação seguida da fotoativação, os dentes foram restaurados com incrementos de resina composta Filtek&#x2122; Z250. Os dentes restaurados foram então imersos em água deionizada e mantidos em estufa a 37oC por um período de 7 dias. Após o armazenamento, os espécimes foram seccionados de modo que se obtivessem palitos com área transversal de aproximadamente 1mm2. De forma aleatória, estes palitos foram separados em 2 grupos: o primeiro submetido imediatamente a testes de microtração em uma máquina de ensaio universal INSTRON 3342 e segundo submetido ao mesmo processo após 1 ano de armazenamento. Os valores de resistência de união foram submetidos aos testes ANOVA e post hoc de Tukey, para que comparações individuais pudessem ser realizadas. Não houve diferença estatisticamente significante entre os lasers utilizados. Os grupos irradiados com ambos os lasers apresentaram resultados similares ao grupo controle, com exceção ao grupo que utilizou o laser de Diodo com menor densidade de energia da (GD3), no qual o resultado foi inferior ao grupo controle no momento imediato. Quedas significativas nos valores de resistência de união foram observadas, com exceção aos grupos que utilizaram o laser de Diodo (GD3 GD2) e o laser Nd:YAG (GNd3). Os diferentes lasers não apresentaram diferença entre si e não foram capazes de promover aumento na resistência e união imediata comparados ao grupo controle. Todos os grupos obtiveram quedas na resistência de união, mesmo em alguns grupos esta queda não sendo significativa. Alterações de alguns parâmetros ou até mesmo a utilização de outro tipo de LASER poderiam ajudar a definir o protocolo ideal para o uso efetivo deste sistema de tratamento adjunto. / The aim of this work was to compare the effect of the irradiation of two types of laser (Nd:YAG and diode laser) on a conventional three-step adhesive system, using three different energy densities of the fiber tip in bond strength immediately and after 1 year. 70 human teeth were selected, and each one had the crown sectioned, exposing the dentin surface for the adhesive and restorative procedures. After teeth preparation, they were randomly divided into 7 groups (n = 10), being 6 test-groups and one control group. Thus, the bonding system Scotchbond&#x2122; Multi-Purpose Plus was applied, and before light cured, the Nd:YAG laser was used in three groups, with three different energy densities of the fiber tip (1 - 509.55 J/cm2, 2 - 254.77 J/cm2 and 3 - 127.38 J/cm2), the same procedures with the same energy densities of the fiber tip were performed for the diode laser. After irradiation followed by light cured, the teeth were restored with composite resin increments (Filtek&#x2122; Z250). The restored teeth were immersed in deionized water and maintained in oven at 37oC for 7 days. After storage, the specimens were sectioned in order to obtain sticks with crosssectional area of approximately 1mm2. Randomly, these sticks were divided into 2 groups: the first one was submitted immediately to microtensile tests in a universal testing machine INSTRON 3342, and the second group was submitted to the same procedure after one year of storage. The bond strength values were submitted to ANOVA and Tukey post hoc tests for individual comparisons. There was no statistically significant difference between the laser s. Irradiated groups showed similar results to the control group, except for the group that used the diode laser with lower energy density of the fiber tip (GD3), in which the results were lower than the control group in the immediate moment. Significant reduction in the values of bond strength were observed, except for the groups that used the diode laser (GD3 - GD2), and the Nd:YAG laser (GNd3). Different lasers did not differ among themselves and were not able to promote an increase in resistance and immediate union compared to the control group. All groups had declines in bond strength, even in some this fall not significant groups. Changes in some parameters or even the use of another type of laser could help define the optimal protocol for the effective use of this adjunctive treatment system.
245

Capacidade de dissolução do hipoclorito de sódio e da clorexidina sobre biofilme oral formado \'in situ\' / Biofilm dissolution and cleaning ability of different irrigant solutions on intraorally infected dentin

Perochena, Aldo Enrique Del Carpio 18 April 2011 (has links)
O objetivo deste estudo foi avaliar o efeito do hipoclorito de sódio e a clorexidina sobre biofilme dental formado in situcom relação a: concentração do hipoclorito de sódio (1%, 2.5% e 5%) e clorexidina 2%, tempo de exposição à solução irrigadora (5, 15 e 30 minutos.), volumes das soluções (500 µl e 1 mL), espessura do biofilme e área de limpeza segundo analise morfométrica. Foram utilizados 120 blocos de dentina bovina esterilizada, colocados em um aparelho intraoral e utilizados por um voluntário durante 3 dias. Transcorrido o período experimental as amostras foram retiradas e coradas com 50 µl de laranja de acridina para determinar a espessura do biofilme pre irrigação por meio do Microscopio confocal de varredura laser (CLSM). Foram conformados 12 grupos experimentais com 10 blocos cada um e irrigados com NaOCl e clorexina. Dez amostras foram irrigadas com 500 µl (N=5) e 1mL (N=5) de NaOCl 1% por: 5 min (G1), 15 min (G2) e 30 min (G3). Dez amostras foram irrigadas com 500 µl (N=5) e 1mL (N=5) de NaOCl 2.5% por: 5 min (G4), 15 min (G5) e 30 min (G6). Dez amostras foram irrigadas com 500 µl (N=5) e 1mL (N=5) de NaOCl 5% por: 5 min (G7), 15 min (G8) e 30 min (G9). Dez amostras foram irrigadas com 500 l (N=5) e 1mL (N=5) de Clorexidina 2% por: 5 min (G10), 15 min (G11) e 30 min (G12). Para cada sub grupo experimental (N=5) se deixou um sexto bloco o qual foi irrigado com água destilada estéril para procedimentos de controle. Nos grupos de 15 e 30 minutos a solução de NaOCl e clorexidina foi renovada a cada 5 minutos. Os segmentos de dentina foram lavados com 200 µl de água destilada estéril para eliminar resíduos não aderidos e corados com 50 µl de Laranja de acridina para determinar a espessura do biofilme após irrigação por meio do CLSM. Foram encontrados altos valores de dissolução do biofilme e dentina limpa após contato com NaOCl a 5% durante 5 e 15 min. e com todos os grupos de NaOCl durante 30 min. O uso de Clorexidina a 2% não dissolveu o biofilme e nem aumentou a limpeza dentinária quando comparado com o NaOCl (P < 0.05). / Introduction: The aim of this study is to evaluate the biofilm dissolution and cleaning ability of different irrigant solutions on intraorally infected dentin. Methods: 120 bovine dentin specimens were infected intraorally using a removable orthodontic device. 30 samples were used for each irrigant solution; 2% Chlorhexidine, 1%, 2.5% and 5.25% of sodium hypochlorite (NaOCl). The solutions were used for 5, 15 and 30 minutes and 2 experimental volume 500µl and 1mL. The samples were stained using the acridine orange dye before and after the experiments and evaluated using a confocal microscope. The percentage of biofilm, isolated cells and no colonized dentin was measured using a grid system. Differences in the reduction or increase of the studied parameters was assessed using non-parametric methods ( P < 0.05). Results: The higher values of biofilm dissolution and clean dentin were found in the 30 minutes NaOCl groups and in the 5 and 15 minutes of 5.25% NaOCL. The use of 2% chlorhexidine solution does not improve the biofilm dissolution neither increases the cleaning of the dentin in comparison to the NaOCl solutions (P < 0.05). Conclusions: 2% chlorhexidine does not dissolve the biofilms. 30 minutes of sodium hypochlorite are necessary to have the higher values of biofilm dissolution and to increase the cleaning of the dentin independently of the concentration in comparison to the 5 min and 15 min contact time.
246

Lasers de Nd:YAG nos regimes de nano e de picossegundos em esmalte e em dentina-análises morfológica e química / Nd:YAG picosecond and nanosecond lasers in enamel and dentin: morphological and chemical analysis

Lizarelli, Rosane de Fátima Zanirato 31 August 2000 (has links)
Vários experimentos têm demonstrado que pulsos ultra curtos no domínio de subpicossegundos promovem uma combinação de efeitos termomecânicos que superam algumas das objeções ao uso de um laser como instrumento removedor. Usando os parâmetros apropriados de operação, lasers com pulsos ultra curtos podem se comportar melhor do que instrumentos convencionais, incluindo alguns dos lasers pulsados comercialmente já disponíveis na Odontologia. A exploração e otimização nos parâmetros dos lasers disponíveis podem promover a remoção de certas objeções ao amplo uso dos lasers. O uso de lasers de pulsos ultra-curtos para ablação de dentes previne o superaquecimento e é uma alternativa para a remoção mecânica de material; além de minimizar o volume desse material removido. Através de estudos morfológicos e químicos, são apresentadas as características de interação laser pulsado - tecido duro dental, com relação a sua largura de pulso - nano ou picossegundos. O objetivo principal é dar início a um novo sistema para ablação de esmalte e dentina humanos: o laser de Nd:YAG no regime de picossegundos. A eficiência da ablação com laser através de um regime de picossegundos minimiza a destruição do material adjacente devido a formação de plasma e ataque. Isso previne a geração excessiva de ondas de choque e promove uma considerável diminuição nos efeitos mecânicos. A diminuição das ondas de choque provavelmente também poderá reduzir a vibração e conseqüentemente a sensação de dor, se aplicado clinicamente. Apesar da baixa taxa de ablação, os resultados mostram a real possibilidade para usar um sistema laser comercial relativamente simples para pulsos em picossegundos que poderia promover a Dentística Operatória Puntual e Seletiva, em outras palavras, seria possível tratar apenas o tecido alterado com seletividade e sem remover tecido sadio ou mesmo promover danos aos tecidos ao redor. Na maioria dos experimentos aqui apresentados, o laser de pulso ultra-curtos apresentou aumento na proporção Ca/P, melhorando a resistência química da superfície irradiada. Além disso, os cortes precisos resultam em superfícies mais lisas, que é importante para prevenir a colonização do biofilme. Outros estudos in vitro são necessários, mudando os parâmetros de energia e simulando situações clínicas para propor o uso efetivo desse sistema in vivo, mas, de fato, o sistema laser em picossegundos pode melhorar a qualidade da Dentística Operatória num futuro breve. / In several already demonstrated experiments, ultrashort laser pulses on the subpicosecond range have been shown to produce a strong thermo-mechanical effect, in several different situations. Even been out side dentistry, the general aspects of subpicosecond pulses interaction with matter are of broad applications on can be used as general references. This strong thermo-mechanical effect has created objections toward the use of such lasers as a material removal too1. On the other hand, using the appropriated parameters of operation, ultra short laser pulses of subnanosecond duration could present better performance than conventional lasers operating at nanosecond regime in several aspects. Through chemical and morphological studies, they are presented the main features from interaction between pulsed laser and dental hard tissue, considering pulse width - nano or picosecond pulse. The main objective is starting to use a new system to ablate human enamel and dentin: Nd:YAG picosecond laser system. Efficient laser ablation in the picosecond regime minimizes destruction of adjacent material due to a plasma formation and etching. This avoids an excessive generation of shock waves and promotes a considerable decrease in mechanical effects. The decreasing of shock waves also reduces vibration and consequently the sensation of pain, if clinically used. Despite the small ablation rate, our results show the real possibility to use a relative simple commercial laser system for picosecond pulses to be use effectively in Dentistry. The real clinical use of a picosecond laser system could promote the Punctual and Selective Operative Dentistry, in other words, we could treat just the decayed tissue with selectivity without remove sound tissue or even promote damage to tissues around. Besides, the precise cuts maybe give us a smoother surface, which is important to prevent biofilm colonization. We need to evaluate more in vitro studies, changing parameters and simulating clinical situations to propose the effective use of this system in vivo, but in fact, we believe that the picosecond laser system can improve the quality of Operative Dentistry in a brief future.
247

Contribuição do glutaraldeído como componente de sistemas adesivos dentinários / Influence of glutaraldehyde priming on bond strengths of an experimental adhesive system applied to wet and dry dentin

Cilli, Renato 10 August 2007 (has links)
Neste trabalho foram testadas as seguintes hipóteses nulas: 1) Não há diferença entre os valores de resistência de união entre resina restauradora e dentina quando uma solução aquosa de glutaraldeído é aplicada como primer dentinário antes do emprego do agente adesivo; 2) Não há diferença entre os valores de resistência de união, quando a aplicação do mesmo sistema adesivo se dá em condições de dentina úmida ou seca. Dentes humanos foram selecionados, e tiveram sua porção oclusal desgastada, expondo a parte média da dentina coronária para adesão. Quatro grupos foram formados, variando-se a aplicação ou não do primer de glutaraldeído e a condição de umidade dentinária: úmida ou seca. Após aplicação e fotopolimerização do sistema adesivo experimental, foram confeccionados blocos resina composta de 4mm de altura sobre a superfície oclusal e os dentes foram preparados para o teste de microtração para a avaliação da resistência de união. Os resultados obtidos foram submetidos à análise de variância a um critério e teste de Tukey (\'alfa\'\'=0,05). A aplicação do primer de glutaraldeído aumentou significativamente os resultados de resistência de união. Não houve diferença estatística entre o mesmo sistema experimental se aplicado em dentina seca ou úmida. A hipótese 1 não se confirma e aceita-se a hipótese 2. / This work tested the following null hypothesis: 1) There is no difference between resin-dentin bond strengths when a glutaraldehyde primer solution is applied onto demineralized dentin during adhesive bonding. 2) There is no difference between resin-dentin bond strengths when the same experimental adhesives systems are applied whether in dry or wet demineralized dentin conditions. Human, extracted upper third molars were selected. The oclusal surfaces were ground flat, and midcoronal dentin was exposed for bonding. Four groups of six teeth were formed. Two groups were designated for dry dentin technique and two for the wet one. After application and photopolymerization of the bonding system, a 4 mm-high resin core build-up was fabricated over the adhesive layer. Specimens were then prepared for microtensile bond test for bond strengths evaluation. The obtained data were submitted to ANOVA and Tukey test (\'alpha\'=0.05). Glutaraldehyde primer application significantly improved resin-dentin bond strength. No significant difference was observed when the same experimental adhesive system was applied whether in dry or wet dentin conditions. Such results require to reject the first null hypothesis and accept the second one.
248

Ação do laser de Nd:YAG intracanal sobre endotoxinas na dentina radicular / Root canal Nd:YAG laser action on endotoxins in the radicular dentin

Archilla, Jose Ricardo de Freitas 16 August 2007 (has links)
As endotoxinas são responsáveis por importantes reações sistêmicas e locais, podendo comprometer o sucesso do tratamento endodôntico. O hidróxido de cálcio, mesmo com limitações, mostra-se como opção única efetiva entre as soluções irrigadoras e as medicações intracanal na redução das endotoxinas nos túbulos dentinários. O experimento realizado avaliou a eficiência do laser de Nd:YAG frente à uma endotoxina inoculada no canal radicular pela utilização de duas cinemáticas de irradiação. Após um período de incubação, confirmada a passagem da endotoxina inoculada no canal radicular através da dentina e do cemento radicular, a irradiação foi realizada ou com cinemática oscilatória ou com cinemática helicoidal, para posterior leitura e comparação com os grupos controle. Os parâmetros utilizados na irradiação com o laser de Nd:YAG de comprimento de onda de 1064 nm foram: 100mJ, 15 Hz, 1,5 W, diâmetro do núcleo da fibra 320 ?m, fluência do pulso 124 J/cm2, largura do pulso 120 ?s e intervalo de relaxação térmica 30 s. Os dados foram comparados pelo método ANOVA, complementado pelo teste de Tukey. As concentrações de endotoxina nos espécimes dos grupos irradiados (helicoidal e oscilatório) foram similares. Além disso, elas também foram similares às dos espécimes controle negativo e significantemente menores (p=0,0271) que as do controle positivo, que não sofreram irradiação. A irradiação com laser de Nd: YAG, nas condições deste experimento é efetiva na inativação da endotoxina da dentina radicular. / The endotoxins are responsible for important systemic and local reactions that could compromise the endodontic success. The calcium hydroxide even with limitations is the only effective option among the irrigant solutions and intracanal medications on the endotoxin reduction in the dentinal tubules. This experiment evaluated the Nd:YAG laser efficacy regarding the inoculated endotoxin in the root canal with two cinematic irradiation procedures. The irradiation was accomplished using an oscillatory and helicoidal technique after an incubation period where the passage of the inoculated endotoxin inside the root canal through dentin and cement was confirmed. Following this the analysis and comparison among the groups was performed. The Nd:YAG laser (?=1064 nm) irradiation, used parameters were: 100mJ, 15 Hz, 1,5 W, core fiber diameter of 320 ?m, pulse fluency of 124 J/cm2, pulse width of 120 ?s and relaxation time interval of 30 s. The data were statistically compared by ANOVA complemented by the Tukey\'s test (p<=0,005). The endotoxin concentration at the irradiated samples, regardless the techniques applied were similar. Moreover these concentrations were also similar to those of negative controls and significantly smaller than those of positive controls that were not irratiated (p=0,0271). The Nd:YAG laser irradiation under this experiment conditions was effective on the root canal endotoxin inactivation.
249

Alteração de temperatura na dentina durante o procedimento restaurador com resina composta variando as fontes fotopolimerizadoras / Temperature alteration in dentin according to the photopolymerization source during composite-resin restorations

Cristiane Savaris 26 January 2009 (has links)
O objetivo deste estudo foi avaliar a influência do tipo de fonte luminosa e da espessura do remanescente dental no aumento de temperatura na câmara pulpar durante a fotopolimerização de uma resina composta. Métodos: Utilizaram-se 96 fragmentos (6x7 mm) obtidos a partir das superfícies vestibulares de incisivos bovinos que foram divididos em 2 grupos e 4 subgrupos (n=12), de acordo com a fonte de luz (LED e luz halógena) e da espessura de remanescente dental (3,5 mm; 3,0 mm; 2,0 mm e 1,0 mm). Foram preparadas cavidades de classe I (3x2 mm), deixando a espessura dos respectivos remanescentes dentais, e restauradas com uma resina composta. A variação de temperatura foi captada por termopares posicionados na dentina do teto da câmara pulpar durante a fotopolimerização (20s) do agente adesivo e de cada incremento de resina composta. Foi considerado o maior valor de temperatura registrado durante todo o procedimento restaurador e também durante a fotopolimerização de cada incremento de resina composta. Os dados foram analisados usando ANOVA e Teste de Fisher (&alpha;=5%). Resultados: O LED promoveu maiores (p<0,05) valores de temperatura do que a luz halógena; os valores mais baixos de temperatura foram (p<0,05) para 3,5 mm de espessura e os maiores para os remanescentes de 1 mm de espessura de remanescente dental; não houve diferença significativa (p>0,05) entre as espessuras de 2,0 mm e 3,0 mm. O aumento de temperatura não foi significativo entre a luz LED e halógena durante a fotopolimerização do agente adesivo, no entanto, os valores registrados no decurso de cada compósito incremento fotopolimerizado foram estatisticamente superiores para a fonte de luz LED. Conclusões: o aumento de temperatura foi dependente do tipo de fonte de luz, da espessura do remanescente dental e do número de sucessivas fotoativações. / Objective: to evaluate the influence of the type of light source and the thickness of remaining dentin on temperature rise in the roof of the pulp chamber during photopolymerization of a composite resin. Methods: 96 tooth fragments (6x7mm) obtained from buccal surfaces of bovine incisors were randomly divided into 2 groups and 4 subgroups (n=12) according to the light source (LED and halogen light) and the thickness of remaining tooth structure (3.5mm, 3.0mm, 2.0mm and 1.0mm). Class I cavities (3x2mm) were prepared, leaving the respective thickness of remaining tooth structure, and restored with a composite resin. Temperature rises were obtained by thermocouples positioned in dentin in the roof of the pulp chamber during photopolymerization (20s) of the adhesive agent and each composite resin increment. It was considered the highest temperature rise registered during the whole restorative procedure and also during photopolymerization of each composite resin increment. Data were analyzed using ANOVA and Fishers Test (&alpha;=5%). Results: LED promoted higher (p<0.05) temperature values than halogen light; temperature values were the lowest (p<0.05) for 3.5- mm-thick remaining and the highest for 1-mm-thick remaining; there was no difference (p>0.05) between thicknesses of 2mm and 3mm. Mean temperature rises were not significant between LED and halogen light during adhesive photopolymerization, however, values registered during each composite increment photopolymerization were statistically superior for LED unit. Conclusions: temperature rise was dependent on the type of light source, on the thickness of remaining tooth structure, and on the number of successive photoactivations.
250

Estudo in vitro do efeito da clorexidina e do etanol na dentina em diferentes condições do substrato dentinário e tempos de armazenagem : Study in vitro the effect of chlorhexidine and ethanol on dentin in different conditions of the dentin substrate and storage times / Study in vitro the effect of chlorhexidine and ethanol on dentin in different conditions of the dentin substrate and storage times

Costa, Ana Rosa, 1977- 05 October 2018 (has links)
Orientador: Regina Maria Puppin Rontani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-10-05T18:49:21Z (GMT). No. of bitstreams: 1 Correr_AnaRosaCosta_D.pdf: 3218831 bytes, checksum: f30505368b581fed81781723b234fbd9 (MD5) Previous issue date: 2013 / Resumo: O propósito deste estudo foi avaliar a influencia de diferentes tipos de substrato (Capitulo 1) e tratamento com etanol 100% (Capitulo 2) ou digluconato de clorexidina a 2% (CHX) (Capitulo 3) na resistência e longevidade da união compósito/dentina, apos diferentes períodos de armazenagem. Os dentes humanos hígidos foram divididos em 3 grupos, de acordo com o substrato dentinario: (Sd) dentina hígida, (Ci) dentina infectada (manutenção da carie) e (Ca) dentina afetada (remoção parcial de carie). As superfícies oclusais de terceiros molares hígidos foram removidas com disco diamantado dupla face sob refrigeração, a fim de expor a superfície plana dentinaria hígida, a qual foi submetida ao desenvolvimento da lesão de carie artificial com S. mutans. Brocas esféricas foram usadas para remover parcialmente o tecido cariado pigmentado, ate que permanecesse apenas a dentina levemente corada (Ca). Em seguida, os dentes foram novamente subdivididos, de acordo com o tratamento da superfície: Grupo Controle (Ct) - nenhum tratamento (Capitulo 1); Ct e (Et) - aplicação de etanol 100% (Capitulo 2); e, Ct e (CHX) - aplicação de digluconato de clorexidina a 2% (Capitulo 3). O substrato foi condicionado com acido fosfórico a 35% por 15 s, lavado por 30 s e seco com leve jato de ar. CHX ou Et foram aplicados apos o condicionamento acido. O sistema adesivo Adper Single Bond 2 (3M ESPE) foi aplicado de acordo com as recomendações do fabricante e fotoativado por 20 s com a fonte de aparelho de luz XL 2500. Sobre a superfície de união foram inseridos incrementos de 2 mm do compósito Z350 (3M ESPE), polimerizados usando a fonte de luz XL 2500 por 40 s, ate confeccionar um bloco com 6 mm de altura. As amostras foram armazenadas em água destilada a 37o C por 24 horas. Apos, os dentes foram seccionados perpendicularmente a área de união, de modo a obter palitos com área de secção transversal de 1mm2. Os palitos foram armazenadas em três períodos: 24 horas, 6 meses e 1 ano. Em seguida, as amostras foram submetidas ao ensaio de resistência de união a microtração usando a maquina de ensaio EZ test (EZS, Shimadzu) a velocidade de 0,5 mm/minuto. Os dados foram submetidos a Analise de Variância e ao teste de Tukey HSD (?=0,05). A união em Sd mostrou valores de resistência de união significativamente maior quando comparado a Ca e Ci. As amostras armazenadas nos períodos de 6 meses e 1 ano resultou na diminuição da resistência de união, independente do tipo de substrato e/ou tratamento. O etanol não foi efetivo em melhorar a resistência de união para os três substratos de dentina avaliados. A clorexidina não influenciou na resistência de união nos períodos de armazenagem avaliados, independente dos substratos / Abstract: The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate (CHX) and 100% ethanol wet-bonding (Et) on the degradation of the adhesive system bond strength in sound or artificial caries-affected/infected dentin after different storage times under microtensile test (_TBS). The sound teeth were divided into 3 groups, according to dentin substrates: sound dentin, caries-infected dentin (maintained of caries) and caries-affected dentin (partial removal of caries). Non-carious human third molars had their occlusal enamel removed with a slow speed diamond saw, under copious water-cooling to expose a flat-surfaced sound dentin, which was submitted to the microbiological challenge (S. mutans) for the development of artificial caries. Spherical drill was used to remove soft pigmented carious tissue till hard and slightly pigmented dentin remains (Ca). After, the teeth will be assigned into 3 subgroups according to surface treatment: water wet- bonding (Ct) (Chapter 1); Ct and 100% ethanol application (Et) (Chapter 2); and, Ct and chlorhexidine digluconate 2% application (CHX) (Chapter 3). The substrate will was etched with 35% phosphoric acid gel for 15 s, rinsed for 30 s with tap water and dried with oil/water-free air. The CHX or Et was applied for 60 s, just after etching with 35% phosphoric acid gel. The adhesive system Adper Single Bond 2 (3M ESPE) was applied according to the manufacturer's instruction and polymerized for 10 s by a light-curing unit XL 2500. The bonded surfaces were coupled with a composite resin Filtek Z350 (3M ESPE) applied in 2 mm increments and polymerized using a curing unit XL 2500 (3M ESPE) for 40 s for each increment and to build 6 mm thick block. The restored teeth were stored in distilled water at 37o C for 24 h. After this period, the restored teeth were longitudinally sectioned across the bonded interface to produce a series of 1.0mm2 beams. The specimens were then submitted to three storage periods: 24 hours, 6 months, or 1 year. Afterwards, the storage periods, the specimens were submitted to a microtensile bond strength (_TBS) using EZ test machine (EZS, Shimadzu) at a crosshead speed of 0.5 mm/min until failure. Data were submitted to ANOVA and Tukey's HSD test (?=0.05). The bonding with sound dentin showed _TBS values significant higher when compared to caries-affected and caries-infected dentin. The 6 months and 1 year storage periods resulted in decreased bond strengths for all dentin conditions and/or treatment. The ethanol was not effective to improve the _TBS for the three dentin substrates evaluated. The CHX did not affect the 24- hour, 6 and 12 months _TBS, independent of the tested dentin substrates / Doutorado / Materiais Dentarios / Doutora em Materiais Dentários

Page generated in 0.0445 seconds