• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 58
  • 6
  • 1
  • Tagged with
  • 66
  • 66
  • 53
  • 32
  • 30
  • 16
  • 11
  • 11
  • 10
  • 10
  • 8
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da estabilidade da aplicação de um híbrido experimental em diferentes concentrações sobre a dentina sensível - in vitro / Evaluation of the stability of application of an experimental hybrid on the sensitive dentin in differents concentrations - in vitro

Oliveira, Tatiane Alexandre de 08 November 2016 (has links)
O objetivo deste estudo foi avaliar, in vitro, quantitativamente e qualitativamente, a estabilidade de um híbrido experimental em duas concentrações diferentes (concentrado e diluído) aplicado sobre a simulação de uma dentina sensível. Dentes molares humanos foram selecionados e tiveram suas coroas seccionadas abaixo do sulco oclusal de forma a obter espécimes de discos de dentina que foram planificados e polidos até atingirem a espessura de 1,0 milímetro. Os espécimes foram divididos em 4 grupos (n=9) de acordo com os tratamentos de superfície propostos: saliva artificial (SAL), adesivo dentinário autocondicionante (AD), híbrido experimental concentrado (TC) e híbrido experimental diluído na proporção de 1:3 (TD). Dois métodos foram empregados para avaliar a estabilidade: condutância hidráulica (permeabilidade dentinária) e microscopia eletrônica de varredura. Foi realizada a leitura da permeabilidade dentinária em 6 tempos experimentais: Mínima (sem tratamento), Máxima (com túbulos abertos), Tratamento (após aplicação dos respectivos tratamentos), Erosão (após 5 minutos de imersão em ácido cítrico 0,05M pH 3,8), Escovação (após escovação de 3900 ciclos) e Erosão Pós (repetição da erosão após o processo de escovação). A microscopia eletrônica de varredura foi realizada em espécimes de dentina com área central de aplicação dos tratamentos e tecido natural nas laterais para evidenciar as características da película aplicada. As leituras foram feitas após a aplicação dos tratamentos, após a erosão, após a escovação e após a erosão pós escovação, para todos os 4 tratamentos propostos. O teste de análise de variância (ANOVA) de Medidas Repetidas com 2 fatores de variação foi aplicado juntamente com o teste de comparações múltiplas pareadas (Tukey). Para permeabilidade dentinária todos os tratamentos reduziram a condutância hidráulica (Lp) em relação à Máxima. TC e TD apresentaram os menores valores (24% e 15%) respectivamente. O TD continuou apresentando valores semelhantes estatisticamente após a Erosão (36%), sendo estatisticamente semelhante ao TC (55%).. No tempo Escovação o TD apresentou Lp estatisticamente semelhante aos tempos Tratamento e Erosão. Todos os grupos apresentaram-se estatisticamente semelhantes entre os tratamentos nos tempos Escovação e Erosão Pós. A análise das MEVs evidencia túbulos dentinários com conteúdo no seu interior nos grupos TC e TD, mantendo-se durante todos os tempos experimentais. O AD apresentou uma película evidente, que começou a se destacar e exibir falhas a partir do tempo Erosão. Conclui-se que o TD apresentou o melhor comportamento sendo capaz de diminuir a permeabilidade dentinária, formando uma película fina, transparente, imperceptível, capaz de vedar (totalmente ou parcialmente) e penetrar dentro dos túbulos dentinários, resistindo aos desafios erosivos e abrasivos. / The aim of this study was to evaluate, in vitro, quantitatively and qualitatively, the stability of an experimental hybrid with two different concentrations (concentrated and diluted) applied at a simulation of a sensitive dentin. Human molar teeth were selected and their crowns were sectioned below the occlusal groove in order to obtain specimens of dentine disks that were ground flat and polished to achieve a thickness of 1.0 millimeter. The specimens were divided into 4 groups (n = 9) in accordance with proposed surface treatments: Artificial saliva (SAL) dentinal self-etching adhesive (AD), concentrated experimental hybrid (TC) and experimental hybrid diluted in the ratio 1: 3 (TD). Two methods were used to assess the stability: hydraulic conductance (dentin permeability) and scanning electron microscopy. The dentin permeability in 6 experimental times was carried out: Minimum (no treatment), Maximum (with open tubules), treatment (after application of their treatments), erosion (after 5 minutes of immersion in citric acid 0.05M pH 3, 8), brushing (brushing after 3900 cycles) and Post erosion (erosion was repeated after brushing). The scanning electron microscopy was performed on dentin specimens with a central area of application of treatments and natural tissues on the sides to show the film characteristics applied. Readings were made after application of treatments, after erosion, after brushing and after erosion after brushing, for all 4 treatments proposed. The analysis of variance (ANOVA) for repeated measures with two variation factors was applied with the multiple comparisons paired test (Tukey). For dentin all treatments reduced hydraulic conductance (Lp) in relation to Maximum. TC and TD showed the lowest values (24% and 15%) respectively. The TD continued to show statistically similar values after erosion (36%), being statistically similar to TC (55%). In brushing time the TD Lp was statistically similar to Treatment and erosion times. All groups were statistically similar between treatments in brushing and Post Erosion times. The analysis of SEM shows dentinal tubules with content inside on the TC and TD groups, remaining during all experimental period. AD presented a clear film, which began to stand out and show failure from erosion time. It follows that the TD had better behavior being able to decrease permeability of dentin by forming a thin film transparent, imperceptible, capable of sealing (fully or partially) and penetrate within the dentine tubules, resisting the erosive and abrasive challenges.
22

Análise quantitativa e qualitativa da condutividade hidráulica da dentina após tratamento com diferentes agentes dessensibilizantes. Estudo in vitro / Quantitative and qualitative analysis of the dentin hydraulic conductance after treatment with different desensitizing agents. In vitro study

Dantas, Luciana Mascarenhas 26 May 2011 (has links)
O tratamento das lesões cervicais não cariosas hipersensíveis com agentes dessensibilizantes pode ser uma opção prática e eficaz devido, principalmente, à capacidade desses produtos de obliterarem os túbulos dentinários expostos. Portanto, o objetivo deste estudo foi analisar, in vitro, o efeito quantitativo e qualitativo de cinco agentes dessensibilizantes em relação ao seu potencial de obstrução dos túbulos dentinários. Para a análise quantitativa, foram utilizados testes de condutividade hidráulica da dentina em diferentes condições experimentais. Os ensaios foram realizados na seguinte sequência experimental: na presença de smear layer (PMin); após condicionamento com ácido fosfórico a 37%, por 15 segundos (PMax); após a aplicação dos agentes dessensibilizantes e após o desafio com ácido cítrico a 6%, por um minuto. Para isso, foram selecionados 50 terceiros molares humanos hígidos não irrompidos, a partir dos quais foram confeccionados discos de dentina com espessura de 0,80 ± 1,00 mm e divididos em 5 grupos (n=10) de acordo com os diferentes agentes dessensibilizantes: Grupo 1 (Sensiactive); Grupo 2 (Sensitive Pro-Alívio); Grupo 3 (Flúor gel);Grupo 4 (Desensibilize Nano-P); e Grupo 5 (Enamel Pro@ Varnish). As medidas de condutividade hidráulica dentinária (Lp) foram analisadas através do teste ANOVA a dois critérios (p<0,05) para se determinar as diferenças intra e intergrupos. As diferenças individuais foram determinadas pelo teste Tukey, também a um nível de significância de 5%. Já a análise qualitativa foi realizada através da observação de imagens feitas através do microscópio confocal a laser (MCL). Nesse caso, foram selecionados 18 terceiros molares humanos hígidos não irrompidos, sendo que a preparação e armazenamento dos discos para as condições experimentais seguiram os mesmos passos descritos para os experimentos de condutividade hidráulica. Os espécimes foram divididos em 6 grupos, n=3, conforme os materiais experimentais estudados, e os discos divididos ao meio de modo a permitir a realização de duas fases do experimento no mesmo disco. Um grupo de discos, metade com smear layer e a outra metade condicionada com ácido fosfórico, foi utilizado como controle. Entendendo que a smear layer e o condicionamento ácido conferem padrões de superfície dentinária conhecidos, os demais grupos foram observados, apenas, com relação aos efeitos dos 5 materiais experimentais e do desafio ácido, realizados sobre a dentina condicionada. Os resultados mostraram que os agentes dessensibilizantes produziram alguma redução na Lp, exceto os Grupos 3 e 5, os quais não mostraram valores de condutividade estatisticamente diferentes da PMax. Com relação ao efeito obstrutivo pós-desafio ácido, o resultado variou entre os diferentes grupos experimentais. Apenas o Grupo 1 foi capaz de manter a mesma Lp da fase pós-tratamento. Os demais produtos apresentaram baixa resistência ao desafio ácido e resultados semelhantes entre si. A confrontação dos resultados de Lp com as imagens em MCL mostra diferentes padrões de precipitação de partículas e sugere que a deposição de cristais na superfície da dentina e no interior dos túbulos não garante o bloqueio do movimento de fluido através dos túbulos dentinários. / The treatment of hypersensitive non carious cervical lesions with desensitizing agents may be a practical and effective alternative, mainly due to the ability of these products to obliterate the exposed dentinal tubules. Therefore, the aim of this study was to investigate, in vitro, the quantitative and qualitative effect of five desensitizing agents in relation to their ability to obstruct dentinal tubules. The quantitative analysis was based on dentin hydraulic conductance tests achieved under different experimental conditions. The tests were performed in the following experimental sequence: in the presence of smear layer (PMin); after a 15-second acid etching (37% phosphoric acid- PMax); after the application of the desensitizing agents; and after a 1-minute acid challenge (6% citric acid). Fifty sound not erupted extracted human third molars were randomly selected and, from them, 0.08±1.00 mm-thickness dentine discs were obtained for distribution into 5 groups (n=10), according to the different desensitizing agents: Group 1 (Sensiactive); Group 2 (Sensitive Pro-Relief); Group 3 (Fluoride gel); Group 4 (Desensibilize Nano-P) and Group 5 (Enamel Pro@ Varnish). Dentin hydraulic conductance measures (Lp) were analyzed by two-way ANOVA (p<0.05) to determine intra and intergroup differences. Individual differences were determined by Tukey test, also at a significance level of 5%. The qualitative analysis was performed by observing images obtained from specimens via laser scanning confocal microscopy (LSCM). Here, 18 sound not erupted extracted human third molars were randomly selected and specimens preparation and storage for each experimental condition followed the same steps described for the experiments regarding dentin hydraulic conductance tests. Specimens were divided into 6 groups (n=3), according to studied materials, and each dentin disc was dimidiate to allow performing of the two phases of the experiment on the same disk. A group of discs, in which one half of each specimen showed smear layer and the other half had been acid-etched (37% phosphoric acid), acted as the control. Understanding that the presence of smear layer and that acidetching provide known dentinal patterns, other groups were observed only with respect to the effects of the 5 experimental materials and of the acid challenge, performed on conditioned dentin. Results showed that the desensitizing agents produced some reduction in Lp, except for Groups 3 and 5, which showed no statistically different conductance values of PMax. Regarding the post-acid challenge obstructive effect, results varied among different experimental groups. Only Group 1 was able to keep the same Lp of the post-treatment phase. Other products offered low resistance to acid challenge and showed similar results among them. Comparison of quantitative (Lp) and qualitative (LSCM) analyses shows different particles precipitation patterns and suggests that the deposition of crystals on the surface and into the dentinal tubules does not block fluid movement through the tubules.
23

Efeito citotóxico transdentinário do peróxido de hidrogênio em diferentes concentrações sobre células de linhagem odontoblástica MDPC-23 /

Huck, Cláudia. January 2005 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Marcelo Ferrarezi de Andrade / Banca: José Carlos Pereira / Resumo: O objetivo da presente pesquisa foi avaliar in vitro os efeitos citotóxicos de diferentes concentrações de um agente clareador de ativação dual à base de peróxido de hidrogênio, sobre células de linhagem odontoblástica MDPC-23. Para isso, 50 discos de dentina com 0,5mm de espessura, obtidos de dentes terceiros molares humanos íntegros, foram tratados com EDTA 0,5 M, pH 7,4 por 1 minuto, sendo a condutância hidráulica (Lp; æL/mm2/min/cm H2O) determinada para cada um deles. Estes discos foram distribuídos em 5 grupos de acordo com os valores de permeabilidade. Os discos de dentina adaptados a um dispositivo metálico foram autoclavados, posicionados de maneira invertida (superfície pulpar dos discos voltados para cima) em recipientes plásticos de 24 compartimentos ("wells"). Então, 5 x 104 células MDPC-23/cm2 foram semeadas em cada compartimento. Após 72 horas de incubação na temperatura de 37º C, 5% de CO2 e 95% de ar, os dispositivos com os discos foram invertidos nos compartimentos, de tal maneira que os materiais experimentais pudessem ser aplicados (2 trocas de 15 minutos cada) sobre a superfície oclusal dos discos, caracterizando os 164 seguintes grupos experimentais: G1: H2O2 7,5%; G2: H2O2 20%; G3: H2O2 35%; e G4: gel base (sem o H2O2). No grupo controle (G5) os discos não foram tratados. Após esta etapa do experimento, o metabolismo das células MDPC-23 que permaneceram aderidas à superfície pulpar dos discos de dentina foi avaliado pela técnica de MTT. A morfologia das células e dentina tratada com os agentes experimentais foram avaliadas em microscopia eletrônica de varredura. A análise estatística de Kruskal-Wallis demonstrou que as três concentrações do agente clareador à base de H2O2 causaram intenso efeito citotóxico sobre as células MDPC-23. As concentrações de 7,5%, 20% e 35% de H2O2 aplicadas sobre os discos de dentina com 0,5mm... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this in vitro study was evaluate the transdentinal effects of an experimental bleaching agent with different concentration of hydrogen peroxide on the immortalized odontoblast-cell line MDPC-23. Fifty dentin disks, 0.5mm thick, cut from extracted non-carious permanent third human molar were conditioned for 1 minute with 0.5M EDTA, pH 7.4 and the hydraulic conductance (Lp; æL/mm2/min/cm H2O) was determined. The dentin discs were adapted to a metallic device which were sterilized and placed in wells of 24-well dishes (the pulpal surface of the discs remained in up position). Then, the cells were plated (5 x 104 cells/cm2) on the pulpal surface of the discs and incubated for 72 hours at 37oC, with 5% CO2 and 95% air. The metallic devices with the adapted dentin discs were inverted into the wells in such way that the experimental bleaching agents were applied on the oclusal surface of the discs for 30 minutes (2 changes of 15 minutes). The different concentration of H2O2 present in the bleaching agent gave rise to the following experimental groups: G1: 7.5% H2O2; G2: 20% H2O2; G3: 35% H2O2; and G4: 0% H2O2. In control group the dentin discs were not 167 submitted to treatment. The metabolism of MDPC-23 cells which remained attached to the pulpal surface of the discs was evaluated by the methyltetrazolium assay (MTT) and the cell and dentin morphology was assessed under scanning electron microscope (SEM). The statistical analysis of Kruskal-Wallis determined that the experimental bleaching agent caused an intense cytotoxic effects on the MDPC-23 cells. This experimental agent containing H2O2 at 7.5%; 20%; and 35% concentration decreased the cell metabolism by 62.65%; 62.28%; and 65.69%, respectively. The complementary statistical test of Mann-Withney demonstrated no difference between groups 1 and 2. The bleaching agent with... (Complete abstract, click electronic address below). / Mestre
24

Cytotoxicity and dentin permeability of carbamide peroxide and hydrogen peroxide vital bleaching materials, in vitro a thesis submitted in partial fulfillment ... Master of Science in Endodontics ... /

Fat, John C. January 1991 (has links)
Thesis (M.S.)--University of Michigan, 1991.
25

Efeito da associação de fosfato de cálcio, laser Nd:YAG e adesivo na permeabilidade dentinária e na resistência de união / Effect of the association of calcium phosphate, Nd:YAG laser and adhesive on dentin permeability and bond strength

Benitez Sellan, Pablo Lenin 11 December 2017 (has links)
Submitted by PABLO LENIN BENITEZ SELLAN null (drpablobens@gmail.com) on 2017-12-14T18:23:53Z No. of bitstreams: 1 Dissertação Pablo Benitez Mestrado Dentistica.pdf: 11665620 bytes, checksum: 383da8829341bad52fdb34ed88ead959 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2017-12-18T15:13:01Z (GMT) No. of bitstreams: 1 benitezsellan_pl_me_sjc.pdf: 11665620 bytes, checksum: 383da8829341bad52fdb34ed88ead959 (MD5) / Made available in DSpace on 2017-12-18T15:13:01Z (GMT). No. of bitstreams: 1 benitezsellan_pl_me_sjc.pdf: 11665620 bytes, checksum: 383da8829341bad52fdb34ed88ead959 (MD5) Previous issue date: 2017-12-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar in vitro o efeito do tratamento com a associação de fosfato de cálcio, laser de Nd:YAG e sistema adesivo na permeabilidade dentinária e na resistência de união. Foram utilizados 60 discos de dentina com aproximadamente 6 mm de diâmetro e 1,5 mm de altura, obtidos de molares humanos hígidos. Os espécimes foram divididos em dois grupos de acordo com a prévia aplicação ou não do fosfato de cálcio (TeethMate Desensitizer - Kuraray Notitake Dental Inc.). Cada grupo foi dividido em três subgrupos conforme o tratamento realizado (n=10): A- Adesivo (Single Bond Universal - 3M-ESPE), AL- Adesivo + Laser (Nd: YAG 60 mJ) , LAL- Laser + Adesivo + Laser. A permeabilidade foi mensurada em três momentos: com smear layer presente (inicial), após a abertura dos túbulos (máxima) e depois do tratamento (final). O percentual da permeabilidade inicial e final foi calculada em relação a permeabilidade máxima. Após a fotopolimerização do adesivo foi aplicado uma camada de 3 mm com a resina composta Filtek Z350 XT (3M-ESPE) com técnica incremental. Os espécimes foram submetidos a 5000 ciclos térmicos e 120.000 ciclos mecânicos, e posteriormente foi utilizado o teste de microtração. Adicionalmente foram observados em microscopia eletrônica de varredura (MEV) e microscopia confocal de varredura a laser (MCVL). Os grupos foram analisados pelo teste da analise de variância (ANOVA), teste t pareado e teste Tukey, adotando o nível de significância de 5%. Não foram observadas diferenças significativas entre os grupos na permeabilidade inicial (p=0,48) e após o tratamento (p=0,70). O percentual de permeabilidade após o tratamento foram (A: 42,11; AL: 39,09; LAL: 35,78; FA: 40,38; FAL: 34,23; FLAL: 30,25). O teste t pareado mostrou que o tratamento LAL promoveu uma redução significativa da permeabilidade em relação à inicial, tendo o fosfato de cálcio sido (p=30,25) ou não aplicado (p=35,78). Os tratamentos tiveram diferenças significativas na resistência de união, foi observado que os grupos FAL(31,53MPa), FLAL(31,37MPa) e AL(29,72MPa) apresentaram as maiores médias, que diferiram estatisticamente dos grupos restaurados só com Adesivo. Os demais grupos não apresentaram diferenças significantes (A: 24,34MPa; FA: 26,40MPa; LAL: 29,68MPa). Podemos concluir que o laser Nd:YAG aplicado antes e depois do sistema adesivo (Com e sem Fosfato de Cálcio), influenciou na redução da permeabilidade dentinária e os diferentes tratamentos na dentina influenciam significativamente a resistência de união entre a dentina e a resina, os grupos FAL, FLAL e AL apresentaram os melhores resultados. A correlação entre os parâmetros não teve influencia. / The objective of this study was to evaluate in vitro effect the association of calcium phosphate, Nd:YAG laser and adhesive system on dentin permeability and bond strength. Sixty dentin discs, approximately 6 mm in diameter and 1,5 mm high, were obtained from healthy human molars. The specimens were divided into two groups according to the prior application of calcium phosphate (TeethMate Desensitizer - Kuraray Noritake Dental Inc.). Each group was divided into three subgroups according to the treatment performed: A-Adhesive (Single Bond Universal - 3M-ESPE), AL- Adhesive + Laser (Nd: YAG 60 mJ) and LAL- Laser + Adhesive + Laser. The dentin permeability was measured in three moments: with smear layer present (initial), after opened tubules (maximum) and after treatment (final). The percentage of the initial and final permeability was calculated in relation to the maximum permeability. After adhesive photopolymerization, was applied the composite resin Filtek Z350 XT (3M-ESPE) with incremental technique. The specimens were cycled to 5000 thermal cycles and 120,000 mechanical cycles, and microtensile bond strength test was applied. Additionally they were observed in scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). The groups were analyzed by ANOVA, paired t test and Tukey test (5%). No significant differences were observed between the groups on initial permeability (p=0.48) and after treatment (p=0.70). Permeability percentage after treatment was (A: 42.11, AL: 39.09, LAL: 35.78, FA: 40.38, FAL: 34.23, FLAL: 30.25). The paired t-test showed that LAL treatment promoted a significant reduction of the permeability in relation to the initial one, with calcium phosphate (p=30.25) or not applied (p=35.78). The treatments had significant differences in bond strength; FAL (31,53 MPa), FLAL (31,37 MPa) and AL (29,72 MPa) groups presented the highest averages, which differed statistically from the groups restored with only Adhesive. The other groups did not present statistically significant differences (A: 24.34 MPa, AF: 26.40 MPa, LAL: 29.68 MPa). It can be concluded that when the Nd:YAG laser was applied before and after the adhesive system (with and without Calcium Phosphate), it influenced the reduction of dentin permeability and the different treatments in dentin significantly influenced the bond strength between dentin and resin , the groups AL, LAL with application of Phosphate and AL without the use of Phosphate showed the best results. The correlation between the parameters had no influence.
26

Avaliação do Clinpro XT® na redução da permeabilidade da dentina radicular e resistência a desafios ácidos, na obliteração de túbulos dentinários e rugosidade superficial da dentina / Clinpro XT® evaluation in reducing the permeability of root dentin and resistance to acids challenges, the obliteration of dentinal tubules and surface roughness of dentin

Terenzi, Mayara [UNESP] 23 March 2016 (has links)
Submitted by MAYARA TERENZI null (mayara_terenzi@hotmail.com) on 2016-05-01T13:15:46Z No. of bitstreams: 3 Dissertação de Mestrado - Mayara Terenzi.pdf: 1718757 bytes, checksum: 20f87c0423de8d0417680da47944a37f (MD5) Anexo A.pdf: 90620 bytes, checksum: 7670a876bb4321d72791935fcb19bfe4 (MD5) Anexo B.tif: 7046482 bytes, checksum: ba852948774319d877a6088b781b43b7 (MD5) / Rejected by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: Foram submetidos 2 arquivos PDF’s e 1 arquivo TIF, a dissertação/tese deve estar em um único arquivo, inclusive os apêndices e anexos e deve estar no formato PDF. Lembramos que o arquivo PDF não deve estar protegido. Corrija estas informações e realize uma nova submissão contendo o arquivo correto. Agradecemos a compreensão. on 2016-05-04T13:37:28Z (GMT) / Submitted by MAYARA TERENZI null (mayara_terenzi@hotmail.com) on 2016-05-10T17:37:12Z No. of bitstreams: 1 Dissertação Mayara 100516.pdf: 8045470 bytes, checksum: 53ac4e21e2f77379964f4bc5b09e8f7a (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-05-12T19:23:37Z (GMT) No. of bitstreams: 1 terenzi_m_me_arafo.pdf: 8045470 bytes, checksum: 53ac4e21e2f77379964f4bc5b09e8f7a (MD5) / Made available in DSpace on 2016-05-12T19:23:37Z (GMT). No. of bitstreams: 1 terenzi_m_me_arafo.pdf: 8045470 bytes, checksum: 53ac4e21e2f77379964f4bc5b09e8f7a (MD5) Previous issue date: 2016-03-23 / O completo entendimento e tratamentos eficazes e definitivos para a hipersensibilidade dentinária, ainda não estão estabelecidos. O grande desafio está em encontrar uma substância que elimine efetivamente a sensação dolorosa não permitindo sua recidiva. O objetivo deste estudo in vitro foi determinar a eficácia do Clinpro XT® na redução da permeabilidade dentinária e avaliar a resistência deste produto a desafios ácidos. O grau de obliteração dos túbulos dentinários e a rugosidade superficial após aplicação do produto, também foram avaliados. Foram utilizados 65 terceiros molares humanos íntegros para a preparação de 65 amostras que foram ligadas a um sistema de pressão hidráulico para mensurar a permeabilidade dentinária após os seguintes passos: (1) preparação da amostra; (2) tratamento com ácido fosfórico a 37% durante 30 segundos; (3) aplicação do Clinpro XT®; (4) primeiro; (5) segundo e (6) terceiro desafios ácidos, respectivamente. As amostras foram divididas aleatoriamente em 5 grupos (n = 13) de acordo com as diferentes soluções ácidas: refrigerante a base de cola, suco natural de limão, vinagre de vinho, vinho branco e energético. 10 terceiros molares adicionais foram utilizados para a preparação de 20 amostras para análise do grau de obliteração dos túbulos dentinários, através da microscopia eletrônica de varredura, e, rugosidade superficial, através de um rugosímetro. Pode-se concluir que Clinpro XT® foi eficaz na redução da permeabilidade dentinária e esse efeito se manteve após três desafios com diferentes substâncias ácidas. Além disso, o produto testado foi capaz de promover a obliteração dos túbulos dentinários e a redução da rugosidade superficial. / The complete understanding and effective and definitive treatment for dentin hypersensitivity are not yet established. The challenge is to find a substance that effectively eliminates the painful sensation not allowing their recurrence. The purpose of this in vitro study was to determine the efficacy of Clinpro XT® in reducing dentin and evaluate the strength of the product acid challenges. The obliteration of the dentinal tubules, and surface roughness after application of the product, were also evaluated. 65 intact human third molars were used for the preparation of 65 samples were bound to a hydraulic pressure system to measure the dentin after the following steps: (1) sample preparation; (2) treatment with 37% phosphoric acid for 30 seconds; (3) application of Clinpro XT®; (4) first; (5) and second (6) third challenges acids, respectively. The samples were randomly divided into 5 groups (n = 13) according to the different acid solutions: refrigerant cola, natural lemon juice, wine vinegar, white wine and energy drink. 10 thirds additional molars were used to prepare 20 samples for analysis of the degree of obliteration of the dentinal tubules, by scanning electron microscopy, and surface roughness, using a roughness. It can be concluded that Clinpro XT® was effective in reducing dentinal permeability and this effect was maintained after three challenges with different acids. Furthermore, the test product is capable of promoting the obliteration of the dentinal tubules and reduce surface roughness.
27

Avaliação da resistência de união à tração e espessura de camada híbrida : influência de sistemas adesivos e condições de substrato dentinário

Susin, Alexandre Henrique [UNESP] 08 October 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-10-08Bitstream added on 2014-06-13T19:01:43Z : No. of bitstreams: 1 susin_ah_dr_arafo.pdf: 3155550 bytes, checksum: 3c18f1511d8950d04d4fb3ead12080d0 (MD5) / O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de união à tração (RUT) e espessura de camada híbrida (ECH), em diferentes condições de substrato dentinário (úmido, S1; desidratado, S2 e reumedecido, S3), proporcionado pelos sistemas adesivos de 4ª geração, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply e One Coat Bond (OCB) - Coltène-Whaledent, e os sistemas adesivos de 5ª geração (autocondicionantes), Clearfil SE Bond (CSEB) - Kuraray e One Up Bond F (OUBF) - Tokuyama. Foram utilizados 180 dentes seccionados na altura do 1/3 médio da coroa, originando duas partes cada um: remanescente dental (utilizado no teste de resistência de união à tração) e fragmento oclusal (utilizado na mensuração de camada híbrida). Para cada um dos 18 grupos foram realizadas 10 repetições em cada um dos dois testes, perfazendo um total de 360 amostras. O teste de RUT, foi realizado na Máquina de Ensaios Mecânicos MTS-810, em velocidade de 2 mm / min., e a ECH, foi mensurada à partir de fotografias obtidas em microscopia eletrônica de varredura (Microscópio Eletrônico JSM 330 A), com o software Image Tool 2.00. No teste de RUT, o desempenho dos sistemas adesivos foi melhor em S1 e, dentre eles, o CSEB foi o que apresentou a maior média, 23,01 MPa, enquanto que a menor, foi apresentada pelo OUBF, 15,69 MPa. Os sistemas adesivos de 4ª geração apresentaram médias intermediárias, às quais não foi possível encontrar diferenças estatisticamente significantes. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2.1, 17,45 MPa e OCB, 19,92 MPa). As menores médias de RUT dos sistemas adesivos de 4ª geração, foram constatadas em S2, apresentando a menor média para o SB, 6,64 MPa, enquanto que os sistemas autocondicionantes, apresentaram menores variações de RUT entre os... . / The aim of this work was to perform the evaluation of the tensile bond strength (TBS) and the thickness of the hybrid layer (THL), in different conditions of dentinal substrate (moist, S1; dehydrated, S2 and remoistened, S3), provided by the fourth generation adhesive systems, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply and One Coat Bond (OCB) - Coltène-Whaledent, and the fifth generation adhesive systems (self-etching), Clearfil SE Bond (CSEB) - Kuraray and One Up Bond F - Tokuyama. One hundred and eighty teeth bisected in the 1/3 crown mean level were used, originating two parts each: dental remnant (used in the tensile bond strength testing) and occlusal fragment (used in the hybrid layer measurement). For each of the 18 groups, 10 repetitions were performed for both tests, in a total of 360 samples. The TBS test was performed in a Mechanic Testing Machine MTS-810, in speed 2 mm/ min, and the THL was measured from photographs obtained in scanning electron microscopy (Electron Microscope JSM 330 A), using a software Image Tool 2.00. During the TBS test, the performance of the adhesive systems was better in S1 and, among themselves, CSEB presented the higher average, 23,01 MPa, while the lower average was presented by OUBF, 15,69 MPa. The fourth generation adhesive systems presented intermediate averages, those which did not revealed statistically significant differences. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2,1, 17,45 MPa and OCB, 19,92 MPa). The lower averages of the fourth generation adhesive systems in TBS were verified in S2, presenting the lower average for SB, 6,64 MPa, while the self-etching systems presented lower TBS variations among the different substrates. In the THL results, lower variability was verified among the average results obtained, being the higher average presented by SBMU, 4,80 æm... (Complete abstract, click electronic address below).
28

Avaliação da resistência de união à tração e espessura de camada híbrida : influência de sistemas adesivos e condições de substrato dentinário /

Susin, Alexandre Henrique January 2002 (has links)
Orientador : Osmir Batista de Oliveira Júnior / Banca: José Roberto Cury Saad / Banca: Maria Salete Machado Cândido / Banca: Edson Alves de Campos / Banca: Denise Pedrini / Resumo: O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de união à tração (RUT) e espessura de camada híbrida (ECH), em diferentes condições de substrato dentinário (úmido, S1; desidratado, S2 e reumedecido, S3), proporcionado pelos sistemas adesivos de 4ª geração, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply e One Coat Bond (OCB) - Coltène-Whaledent, e os sistemas adesivos de 5ª geração (autocondicionantes), Clearfil SE Bond (CSEB) - Kuraray e One Up Bond F (OUBF) - Tokuyama. Foram utilizados 180 dentes seccionados na altura do 1/3 médio da coroa, originando duas partes cada um: remanescente dental (utilizado no teste de resistência de união à tração) e fragmento oclusal (utilizado na mensuração de camada híbrida). Para cada um dos 18 grupos foram realizadas 10 repetições em cada um dos dois testes, perfazendo um total de 360 amostras. O teste de RUT, foi realizado na Máquina de Ensaios Mecânicos MTS-810, em velocidade de 2 mm / min., e a ECH, foi mensurada à partir de fotografias obtidas em microscopia eletrônica de varredura (Microscópio Eletrônico JSM 330 A), com o software Image Tool 2.00. No teste de RUT, o desempenho dos sistemas adesivos foi melhor em S1 e, dentre eles, o CSEB foi o que apresentou a maior média, 23,01 MPa, enquanto que a menor, foi apresentada pelo OUBF, 15,69 MPa. Os sistemas adesivos de 4ª geração apresentaram médias intermediárias, às quais não foi possível encontrar diferenças estatisticamente significantes. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2.1, 17,45 MPa e OCB, 19,92 MPa). As menores médias de RUT dos sistemas adesivos de 4ª geração, foram constatadas em S2, apresentando a menor média para o SB, 6,64 MPa, enquanto que os sistemas autocondicionantes, apresentaram menores variações de RUT entre os... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this work was to perform the evaluation of the tensile bond strength (TBS) and the thickness of the hybrid layer (THL), in different conditions of dentinal substrate (moist, S1; dehydrated, S2 and remoistened, S3), provided by the fourth generation adhesive systems, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply and One Coat Bond (OCB) - Coltène-Whaledent, and the fifth generation adhesive systems (self-etching), Clearfil SE Bond (CSEB) - Kuraray and One Up Bond F - Tokuyama. One hundred and eighty teeth bisected in the 1/3 crown mean level were used, originating two parts each: dental remnant (used in the tensile bond strength testing) and occlusal fragment (used in the hybrid layer measurement). For each of the 18 groups, 10 repetitions were performed for both tests, in a total of 360 samples. The TBS test was performed in a Mechanic Testing Machine MTS-810, in speed 2 mm/ min, and the THL was measured from photographs obtained in scanning electron microscopy (Electron Microscope JSM 330 A), using a software Image Tool 2.00. During the TBS test, the performance of the adhesive systems was better in S1 and, among themselves, CSEB presented the higher average, 23,01 MPa, while the lower average was presented by OUBF, 15,69 MPa. The fourth generation adhesive systems presented intermediate averages, those which did not revealed statistically significant differences. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2,1, 17,45 MPa and OCB, 19,92 MPa). The lower averages of the fourth generation adhesive systems in TBS were verified in S2, presenting the lower average for SB, 6,64 MPa, while the self-etching systems presented lower TBS variations among the different substrates. In the THL results, lower variability was verified among the average results obtained, being the higher average presented by SBMU, 4,80 æm... (Complete abstract, click electronic address below). / Doutor
29

Influência dos tratamentos dessensibilizantes associados ao laser de diodo na permeabilidade dentinária / Influence of desensitizing treatments associated with diode laser on dentin permeability.

Júlia Olien Sanches 10 January 2013 (has links)
Objetivo: Este estudo avaliou o efeito dos agentes dessensibilizantes associados ou não ao laser de diodo na permeabilidade dentinária e na morfologia da superfície. Materiais e Métodos: Para este estudo, 104 espécimes de dentina radicular bovina foram divididos aleatoriamente em 4 grupos e 2 subgrupos (n=13): G1A= nenhum tratamento (controle), G1B= laser de diodo, G2A= Oxagel, G2B= laser de diodo + Oxagel, G3A= Mi Paste, G3B= laser de diodo + Mi Paste, G4A= Sensitive Pró-Alívio dessensibilizante, G4B= laser de diodo + Sensitive Pró-Alívio dessensibilizante. Para análise da permeabilidade, 10 espécimes de cada grupo foram imersos em ácido clorídrico a 1% durante 20 segundos, 3 vezes, com intervalo de 2 horas entre as imersões, para exposição dos túbulos dentinários. A aplicação dos agentes dessensibilizantes foi feita de acordo com as instruções do fabricante e a irradiação com o laser de diodo foi feita no modo contato, comprimento de onda de 970 nm +/- 10 nm, potência máxima de 7 W CW, frequência de 10 Hz, durante 25 segundos. Em seguida, os espécimes foram submetidos à coloração histoquímica e seccionados para serem analisados quanto à permeabilidade por meio de microscopia óptica (MO). A permeabilidade dentinária foi dada pela porcentagem de penetração do corante em relação à área total do espécime seccionado. Os espécimes remanescentes (n = 3) foram utilizados para análise microscópica da superfície que foi dividida em duas áreas (controle e tratada). A exposição dos túbulos dentinários e a aplicação dos tratamentos foram realizadas da forma já descrita e, na sequência, os espécimes foram avaliados em microscopia eletrônica de varredura (MEV). Os valores obtidos de permeabilidade foram analisados através da ANOVA. Resultados: Nenhuma diferença estatística significante foi observada entre os tratamentos. Na microscopia eletrônica de varredura, foi observada uma ligeira diferença entre a área tratada e a área controle, exceto no grupo 4B. Comparando os grupos A e B (sem e associado ao laser, respectivamente), nenhuma mudança significativa foi notada na superfície dentinária. Conclusão: A aplicação dos agentes dessensibilizantes associados ou não ao laser diodo não influenciou na permeabilidade dentinária radicular e na morfologia da superfície dentinária. / Objective: This study evaluated the effect of desensitizing agents associated or not with laser diode on dentin permeability and surface morphology. Materials and Methods: For this study, 104 bovine root dentin specimens were randomly divided into 4 groups and 2 subgroups (n = 13): G1A = no treatment (control), G1B= diode laser, G2A= Oxagel, G2B= diode laser + Oxagel, G3A= Mi Paste, G3B= diode laser + Mi Paste, G4A= Sensitive Pro-Relief desensitizing, G4B= diode laser + Sensitive Pro-Relief desensitizing. For permeability analysis , 10 specimens were immersed in 1% hydrochloric acid for 20 seconds, three times, with an interval of 2 hours between them, to expose the dentinal tubules. The application of desensitizing agents was performed according to the manufacturers instructions and the irradiation with the laser diode was made on contact mode, wavelength of 970 nm +/- 10 nm, maximum output 7 W CW, 10 Hz, for 25 seconds. After that, the specimens were imaged in an optical microscope (OM) and permeability was measured in the digitized images as the percentage of cooper ions penetration over the total area. The remaining specimens (n = 3) were used for surface microscopic analysis and they were divided in two areas (control and treated). The dentinal tubules exposure and the treatments application were performed as previously described and then analysed in scanning electron microscopy (SEM). The permeability values were analyzed using ANOVA. Results: No statistical significant difference among the treatments was observed. For scanning electron microscopy, there was a slight difference between the treated and control area, except for group 4B. Comparing groups A and B (without and associated with laser, respectively), no significant change was verified on the dentin surface. Conclusion: The application of desensitizing agents associated or not with diode laser did not affect the root dentin permeability and the dentin surface morphology.
30

Atividade antibacteriana de sistemas adesivos dentinários autocondicionantes sobre bactérias cariogênicas

Gondim, Juliana Oliveira [UNESP] 30 November 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-11-30Bitstream added on 2014-06-13T19:56:38Z : No. of bitstreams: 1 gondim_jo_me_arafo.pdf: 487270 bytes, checksum: 789b8f434824d723680740b007e8975b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A incorporação de agentes antibacterianos aos sistemas adesivos dentinários autocondicionantes tem sido proposta com o intuito de eliminar bactérias residuais presentes na dentina, prevenindo, assim, a recorrência de cárie. O presente trabalho teve como objetivo avaliar a atividade antibacteriana dos sistemas adesivos dentinários autocondicionantes: Clearfil Protect Bond (CPB), Clearfil SE Bond (CSEB), Xeno III (XIII) e Clearfil Tri-S Bond (C3SB), com e sem fotoativação, sobre bactérias cariogênicas, bem como a influência da dentina humana na atividade antibacteriana destes sistemas adesivos, utilizando o método de difusão em ágar. A solução de digluconato de clorexidina a 0,2% foi utilizada como controle positivo. O componente adesivo do CPB e do CSEB, o líquido A do XIII e o C3SB não apresentaram atividade antibacteriana quando aplicados sobre discos de papel. O conjunto primer e adesivo do CPB não fotoativado promoveu a maior inibição contra S. mutans (p<0,05), enquanto que com a fotoativação, não houve diferença entre esses componentes juntos e o primer isoladamente. Para o L. acidophillus, o primer do CPB apresentou a maior atividade antibacteriana nas duas condições de fotoativação (p<0,05). Quando os materiais foram aplicados sobre discos de dentina, somente a CHX promoveu efeito inibitório, o qual foi de menor intensidade do que quando aplicada sobre discos de papel (p<0,05). A CHX apresentou maior atividade antibacteriana sobre S. mutans quando comparado com L. acidophillus (p<0,05). Pode-se observar que a fotoativação reduziu significantemente a 18 atividade antibacteriana dos sistemas adesivos autocondicionantes, que a presença do MDPB no sistema adesivo dentinário é importante para a atividade antibacteriana sobre bactérias cariogênicas, e que a dentina atua como barreira de proteção eliminando ou reduzindo a ação antibacteriana de materiais odontológicos. / The incorporation of antibacterial agents in self-etching dentin bonding systems has been introduced in attempts to eliminate dentin residual bacteria, preventing secondary caries. Therefore, the aim of this study was to evaluate the antibacterial activity of cured and uncured self-etching dentin bonding systems Clearfil Protect Bond (CPB), Clearfil SE Bond (CSEB), Xeno III (XIII) and Clearfil Tri-S Bond (C3SB), against S. mutans and L. acidophillus, by the agar disc-diffusion test, as well as to evaluate the influence of human dentin on their antibacterial activity. A 0.2% aqueous solution of chlorhexidine (CHX) was used as a positive control. CPB and CSEB bond component, liquid A of Xeno III and C3SB did not show any antibacterial activity when applied onto paper discs. The primer and bond set of uncured CPB presented the strongest inhibitory activity against S. mutans (p<0.05), however after light-activation, no difference was observed between these components together and when primer was applied individually. Independently of light-activation conditions, CPB primer showed the strongest antibacterial activity against L. acidophillus (p>0.05). When the materials were applied onto dentin discs, only CHX presented inhibitory activity, which was less intense than when it was applied onto paper discs (p<0.05). CHX showed stronger antibacterial activity against S. mutans than against L. acidophillus (p<0.05). In conclusion, light-activation significantly reduced the antibacterial activity, the presence of MDPB in adhesive systems is important to the inhibitory effect against cariogênico 20 bacteria, and the dentin acted as a protection barrier reducing or inhibiting the antibacterial activity of dental materials.

Page generated in 0.1017 seconds