• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 37
  • 8
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 49
  • 49
  • 37
  • 36
  • 28
  • 22
  • 21
  • 20
  • 19
  • 19
  • 15
  • 15
  • 13
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

AVALIAÇÃO CLÍNICA E LABORATORIAL DE RESTAURAÇÕES COM RESINA BULK FILL INSERIDAS DE FORMA INCREMENTAL OU EM INCREMENTO ÚNICO / Clinical and laboratorial evaluation of bulk fill restorations placed in incremental or bulk filling

Costa, Thays Regina Ferreira da 18 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:21:59Z (GMT). No. of bitstreams: 1 Thays Regina Ferreira da Costa.pdf: 2858725 bytes, checksum: f9f6052000f0a266a63eb325bc5d7b68 (MD5) Previous issue date: 2016-02-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objectives: In the experiment 1, an in vitro study, the aim was to evaluate the microtensile bond strength (μTBS), nanoleakage (NL) and degree of conversion (DC) of different bulk-fill resin-based materials placed in bulk [BUL] or incrementally [INC] and in the experiment 2, a double blind randomized clinical trial, split mouth for each adhesive system, was conducted to compare the postoperative sensitivity of a bulk-fill resin-based material placed in BUL or INC in posterior composite resin restorations bonded with two different adhesive strategies (self-etch and etch-and-rinse). In the experiment 3, the objective was to describe the clinical steps involved in the placement of posterior composite resin restorations with bulk-fill resins. Materials and methods: In experiment 1, flat dentin surfaces of thirty extracted teeth were exposed and then were randomly assigned into 6 experimental conditions (n = 5). Composite buildups were constructed according to the combination of the main factors filling technique (BUL [single 4-mm thick layer] and INC [two 2-mm thick layers]) and composite resin (Filtek Bulk Fill Flow [FIL], 3M ESPE, Tetric N-Ceram Bulk Fill [TET], Ivoclar Vivadent and SureFil SDR Flow [SDR], Dentsply Caulk) with their respective conventional adhesive systems. Teeth were sectioned to obtain bonded sticks (0.8 mm2) to be tested in tension (0.5 mm/min) for μTBS. For NL, two bonded sticks from each tooth were placed in 50% silver nitrate and polished with SiC paper and then analyzed using scanning electron microscopy. For DC, three specimens per tooth were analyzed in micro-Raman spectroscopy. The mean μTBS (MPa) NL (%) and DC (%) data were submitted to a two-way ANOVA and Tukey´s test (α = 0.05). In experiment 2, a total of 236 posterior dental cavities with a cavity depth of at least 3 mm (72 participants) were randomly divided in four groups (n=59). Restorations were bonded either with the etch-and-rinse Tetric N-Bond (Ivoclar Vivadent) or with the self-etch Tetric N-Bond SE (Ivoclar Vivadent). The composite resin TET (Ivoclar-Vivadent) was placed either INC or in BUL techniques. Two experienced and calibrated examiners performed the evaluation of the restorations using the FDI criteria after one week of clinical service. Spontaneous postoperative sensitivity was assessed using a 0-4 and a 0-100 numerical rating scale (NRS), and a 0-10 visual analog scale (VAS) up to 48 h after the restorative procedure and one-week later. Results: In experiment 1, higher μTBS values (mean ± SD) were observed for FIL (57.5 ± 3.5) in the BUL technique when compared to other groups inserted in BUL (TET 52.6 ± 7.8; SDR 54.9 ± 4.3) or INC filling (FIL 51.8 ± 4.1; TET 47.9 ± 4.5; SDR 49.7 ± 3.8) - p > 0.05. No statistically significant difference was observed among the materials tested (p > 0.05). No significant difference was 9 detected in NL (FIL [7.6 ± 1.9 INC and 10.3 ± 2.3 BUL]; TET [10.9 ± 3.3 INC and 12.8 ± 4.0 BUL]) and DC (FIL [87.9 ± 7.0 INC and 85.6 ± 8.4 BUL]; TET [92.2 ± 3.4 INC and 83.3 ± 5.4 BUL]) between filling technique (p > 0.05). Higher NL values (13.0 ± 3.6 INC and 14.8 ± 2.5 BUL [p = 0.001]) and lower DC (49.7 ± 8.3 INC and 48.6 ± 4.0 BUL [p = 0.003]) were found when SDR was used. In experiment 2, neither the restorative technique nor the adhesive strategy affected the risk (p > 0.49) and intensity of spontaneous postoperative sensitivity (p > 0.38). The overall risk of postoperative sensitivity observed was 20.3% (95% CI 15.7 to 25.9) and occurred practically within the 48 h after the restorative procedure. Conclusions: The filling technique did not affect the μTBS, NL and DC of the bulk fill materials tested in this study. Clinically, the use of single increment of this new bulk-fill material, even in deep restorations, did not generate more postoperative sensitivity when compared to the incremental filling technique. / Objetivos: No experimento 1, um estudo in vitro, o objetivo foi avaliar a resistência de união (RU), nanoinfiltração (NI) e grau de conversão (GC) de diferentes resinas compostas bulk fill inseridas de forma incremental (INC) ou em incremento único (UNI) e no experimento 2, um ensaio clínico randomizado duplo-cego de boca dividida para cada sistema adesivo, foi comparar a sensibilidade pós-operatória em restaurações realizadas com resina bulk fill em dentes posteriores variando a técnica de inserção (UNI e INC) e a estratégia adesiva (convencional e autocondicionante). No experimento 3, o objetivo foi realizar um relato de caso clínico demonstrando os passos clínicos envolvidos na execução de restaurações posteriores com uma resina bulk fill. Material e métodos: No experimento 1, trinta terceiros molares tiveram sua dentina planificada e exposta, foram divididos aleatoriamente em seis condições experimentais (n=5) e restaurados de acordo com a combinação dos fatores: técnica de inserção (UNI [uma camada de 4 mm] ou INC [2 camadas de 2 mm cada]) e resina composta (Filtek Bulk Fill Flow [FIL], 3M ESPE, Tetric N-Ceram Bulk Fill [TET], Ivoclar Vivadent e SureFil SDR [SDR], Dentsply Caulk) com seus respectivos sistemas adesivos convencionais. Os dentes foram seccionados para obtenção de palitos (0,8 mm2) para serem testados em microtração (0,5 mm/min) para RU. Para NI, dois palitos de cada dente foram infiltrados com nitrato de prata amoniacal 50%, revelados, polidos com lixas de carbeto de silício com granulação crescente e avaliados em microscopia eletrônica de varredura. Para GC, três palitos por dente foram levados ao micro-Raman para análise do grau de conversão. As médias de RU (MPa), NI (%) e GC (%) foram submetidos a uma análise de variância de dois fatores e Teste de Tukey (α = 0,05). No experimento 2, setenta e dois participantes tiveram 236 cavidades com profundidade mínima de 3 mm randomicamente divididas em 4 grupos experimentais (n=59). Os sistemas adesivos utilizados foram o convencional Tetric N-Bond (Ivoclar Vivadent) ou o autocondicionante Tetric N-Bond SE (Ivoclar Vivavent). A resina composta utilizada foi TET (Ivoclar Vivadent), que foi inserida de forma INC ou UNI. Dois avaliadores experientes e calibrados avaliaram as restaurações utilizando os critérios da FDI uma semana após a inserção das restaurações. A sensibilidade pós-operatória imediata foi mensurada utilizando duas escalas numéricas, de 0-4 e de 0-100 e uma escala VAS de 0-10 até 48 horas após o procedimento restaurador e uma semana após. Resultados: No experimento 1, maiores valores de RU (média ± DP) foram observados para a FIL inserida na técnica UNI (57,5 ± 3,5) em comparação com os outros grupos: UNI (TET 52,6 ± 7,8; SDR 54,9 ± 4,3) ou INC (FIL 51,8 ± 4,1; TET 47,9 ± 4,5; SDR 49,7 ± 3,8) - p > 0,05. Não foi observada diferença estatisticamente 7 significante entre os materiais (p > 0,05). Para NI (%) (FIL [7,6 ± 1,9 INC e 10,3 ± 2,3 UNI]; TET [10,9 ± 3,3 INC e 12,8 ± 4,0 UNI]) e GC (%) (FIL [87,9 ± 7,0 INC e 85,6 ± 8,4 UNI]; TET [92,2 ± 3,4 INC e 83,3 ± 5,4 UNI]), não foram observadas diferenças entre as técnicas de inserção do material (p > 0,05). Maiores valores de NI (13,0 ± 3,6 INC e 14,8 ± 2,5 UNI [p = 0,001]) e menores valores de GC (49,7 ± 8,3 INC e 48,6 ± 4,0 UNI [p = 0,003]) foram encontrados para resina SDR. No experimento 2, nem a técnica de inserção e nem a estratégia adesiva alterou o risco de sensibilidade pós-operatória (p > 0,49) e a intensidade da sensibilidade (p > 0,38). O risco geral de sensibilidade pós-operatória observado foi de 20,3% (IC 95% 15,7 - 25,9) e ocorreu praticamente dentro das 48 horas após o procedimento restaurador. A técnica operatória mostrou-se simples e mais rápida de execução que a realizada de acordo com o protocolo de inserção incremental. Conclusões: A técnica de inserção não afeta a RU, NI e GC dos materiais utilizados no presente estudo. Clinicamente, o uso de resinas bulk fill inseridas em incremento único, mesmo em cavidades profundas, não aumenta a sensibilidade pós-operatória quando comparado com a inserção incremental, independentemente da estratégia adesiva utilizada.
42

AVALIAÇÃO CLÍNICA DA INFLUÊNCIA DO CAFÉ NA EFETIVIDADE DO CLAREAMENTO DENTAL / Clinical evaluation of the influence of coffee in the effectiveness of dental bleaching

Siqueira, Márcia Fernanda de Rezende 29 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:19Z (GMT). No. of bitstreams: 1 MARCIA FERNANDA DE REZENDE SIQUEIRA.pdf: 1854900 bytes, checksum: 25353ada2c457db2da3208c5e6d94257 (MD5) Previous issue date: 2012-02-29 / The objective of this clinical study was to evaluate whether exposure to coffee during the bleaching treatment with PC 16 (Whiteness Perfect, FGM,Joinville, Santa Catarina, Brazil) affects the degree of whitening and tooth sensitivity. We selected 40 patients with central incisors darker than A2, which were divided into 2 groups (n=20): GC - control group and GE - the experimental group. For the CG was no restriction of foods with dyes and the GE patients beyond the usual coffee intake in his diet made with black coffee rinses soluble Nescafé® Tradição (Nestlé), 4 times daily for 30 seconds. For both groups we used PC 16 for a period of 3 hours daily for 3 weeks. The color scale was assessed by spectrophotometer Easyshade and in the periods: initial, during the whitening (1 st, 2 nd and 3 rd week) and postbleaching (1 week and 1 month). Patients recorded their perceptions of sensitivity through the NRS scale (0-4) and VAS. For the color analysis was performed analysis of variance (ANOVA) with repeated measures on two factors (time vs. treatment groups), time being the repeated measure (=0.05). We carried out the Tukey test for contrast of means (=0.05). The tooth sensitivity was evaluated by Fisher's exact test and the intensity of tooth sensitivity was evaluated by Mann-Whitney test (=0.05) for both scales. There effectiveness of tooth whitening over time (p <0.001). For both groups was not statistical differences in absolute risk of sensitivity between the groups (p=1.0). Most patients had mild tooth sensitivity and no statistically significant difference was detected between groups for both the NRS scale (p=0.529) and for the VAS (p=0.258). It was concluded that dental bleaching is effective for the groups studied, which makes possible the consumption of coffee during the bleaching treatment. / O objetivo deste estudo clínico foi avaliar se a exposição ao café durante o tratamento clareador com PC 16% (Whiteness Perfect, FGM, Joinville, Santa Catarina, Brasil) afeta o grau de clareamento e a sensibilidade dental. Foram selecionados 40 pacientes com os incisivos centrais mais escuros que A2, os quais foram divididos em 2 grupos (n=20): GC - grupo controle e GE - grupo experimental. Para o GC houve restrição de alimentos com corantes e para o GE os pacientes, além da ingestão usual do café na sua dieta, realizaram bochecho com café preto solúvel Nescafé Tradição (Nestlé) 4 vezes ao dia, por 30 segundos. Para os dois grupos utilizou-se PC 16% pelo período de 3h diariamente, durante 3 semanas. A cor foi avaliada através da escala Vita Classical e espectrofotômetro Vita Easyshade, nos períodos: inicial, durante o clareamento dental (1ª, 2ª e 3ª semanas) e pós-clareamento (1 semana e 1 mês). Os pacientes registraram suas percepções de sensibilidade através da escala NRS (0-4) e VAS. Para a análise de cor foi efetuada ANOVA de dois fatores (grupos vs tempo de tratamento), sendo o tempo a medida repetida (=0,05). Foi realizado o teste de Tukey para o contraste das médias =0,05). A sensibilidade dental foi avaliada pelo teste exato de Fisher e a intensidade da sensibilidade dental foi avaliada pelo teste Mann-Whitney (=0,05) para ambas as escalas. Houve efetividade do clareamento dental ao longo do tempo (p<0,001). Para ambos os grupos não foi verificada diferença estatística no risco absoluto de sensibilidade entre os grupos (p=1,0). A maioria dos pacientes apresentou sensibilidade dental leve e não foi detectada diferença estatisticamente significante entre os grupos, tanto para a escala NRS (p=0,529) como para a VAS (p=0,258). Concluiu-se que o clareamento dental foi eficaz para os grupos avaliados, o que torna possível o consumo de café durante o tratamento clareador.
43

EFEITO DE DOIS ANTI-INFLAMATÓRIOS E UM ANTIOXIDANTE NA PREVENÇÃO DA SENSIBILIDADE CAUSADA PELO CLAREAMENTO DENTAL / Effect of two anti-inflammatories and one antioxidant to prevent bleaching-induced tooth sensitivity

Paula, Eloisa Andrade de 05 December 2013 (has links)
Made available in DSpace on 2017-07-24T19:22:32Z (GMT). No. of bitstreams: 1 Eloisa Andrade de Paula.pdf: 11594237 bytes, checksum: 25299b2f989c0877ee886949439d03c9 (MD5) Previous issue date: 2013-12-05 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The tooth bleaching has a long history of tooth sensitivity (TS). This study aimed to determine the effect of different drugs, administered perioperatively, on tooth sensitivity and the degree of tooth whitening after in-office bleaching. A triple-blind,parallel design, randomized clinical trial were conducted. In the first experiment, the participants received a placebo or 400 mg ibuprofen every 8 h while in the second experiment, they were given a placebo or 60 mg etoricoxib every 24 h. In the third experiment, they received a placebo or 500 mg ascorbic acid every 8 h. In all experiments, the first dose of the drug was administered 1 h before in-office bleaching and taken for a period 48 h. The 35% hydrogen peroxide gel (Whiteness HP Maxx, FGM) was used in three 15-min applications for three groups following the manufacturer's directions. The in-office bleaching agent was refreshed every 15 min.Two bleaching sessions, with a one-week interval, were performed on each patient. The shade evaluation were performed before and 30-days, after bleaching with a Vita Easy Shade spectrophotometer and a Vita Classical’s visual shade guide. The tooth sensitivity was recorded on three scales: the five-point verbal rating scale, the 101 points scale, and the visual analogue scale, of and in different time points up to 1 h, 24 h, 48h after bleaching. The % of patients that reported TS at least once during treatment were evaluated by Fisher`s exact and the intensity of tooth sensitivity with Mann-Whitney test. Tooth color changes were evaluated by repeated ANOVA measures and t-test. There were no significant differences in the % of patients with tooth sensitivity and color change between the groups. The lowest tooth sensitivity was observed in the 400 mg ibuprofen group only up to 1 h post bleaching. The perioperative use of ibuprofen, etoricoxib and ascorbic acid per oral route was not able to avoid bleaching-induced tooth sensitivity according to the posology and dose used in this study. However, the 400 mg ibuprofen was able to reduce the intensity of tooth sensitivity up to 1 h post bleaching. / As técnicas de clareamento dental em dentes vitalizados podem apresentar o inconveniente de causarem sensibilidade dental. Neste estudo foram realizados três experimentos com o objetivo de determinar o efeito de dois anti-inflamatórios e um antioxidante utilizados previamente e durante o procedimento de clareamento dental em consultório na sensibilidade dental e no grau de clareamento alcançado. Estes experimentos foram do tipo estudo clínico, randomizado, paralelo, controlado por placebo e triplo cego. No experimento 1, os participantes receberam placebo ou ibuprofeno 400 mg a cada 8 h. No experimento 2, os participantes receberam placebo ou etoricoxibe 60 mg a cada 24 h. No experimento 3, os participantes receberam placebo ou ácido ascórbico 500 mg a cada 8 h. Em todos os experimentos os medicamentos foram administrados 1 hora antes do início do tratamento clareador por um período total de 48 h. Em cada sessão de clareamento, o gel de peróxido de hidrogênio 35% (Whiteness HP Maxx, FGM) foi aplicado 3 vezes durante 15 minutos cada, de acordo com as instruções do fabricante e repetido depois de uma semana, seguindo o mesmo protocolo. As alterações de cor foram avaliadas antes e 30 dias após o tratamento clareador utilizando o espectrofotômetro Vita Easy Shade e a escala de cor Vita Clássica organizada por ordem de valor. Três escalas destinadas a avaliar a intensidade da dor (escala verbal de 5 pontos, escala numérica de 101 pontos e escala visual analógica) foram utilizadas para determinar o nível de sensibilidade imediatamente até 1 h, 24 h e 48 h após o tratamento de clareamento em consultório. A porcentagem de pacientes que relataram sensibilidade, ao menos uma vez durante o tratamento, e a intensidade da sensibilidade dental foram avaliadas pelo teste exato de Fischer e teste de Mann-Whitney, respectivamente. As alterações de cor dental foram determinadas por medidas repetidas ANOVA 1 critério e teste t. Não foram detectadas diferenças significativas no percentual de pacientes que apresentaram sensibilidade e nem na alteração de cor. Somente o medicamento ibuprofeno 400 mg apresentou redução da intensidade da sensibilidade na primeira hora após o tratamento clareador. Os medicamentos não foram capazes de prevenir e nem mesmo minimizar a sensibilidade dental quando administrados de acordo com a posologia e dose empregadas neste estudo.
44

Uso da dexametasona para prevenção da sensibilidade dental pós-clareamento em consultório: Estudo clínico randomizado, triplo cego, placebo-controlado / Use of dexamethasone for prevention of tooth sensitivity post-office bleaching: a randomized, triple blind, placebo-controlled clinical trial

Siqueira, Márcia Fernanda de Rezende 14 November 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:36Z (GMT). No. of bitstreams: 1 Marcia Rezende Siqueira.pdf: 2318467 bytes, checksum: aa953a2e63a73132eda862bf28e7254d (MD5) Previous issue date: 2014-11-14 / The main adverse effect of dental bleaching is tooth sensitivity (TS). This study aimed to determine the effect of dexamethasone on TS caused by in-office bleaching. A randomized, parallel design, placebo-controlled, triple-blind, clinical trial was selected on 63 health and young adults who received either a placebo (PG) and dexamethasone (DG). The drugs (8mg) were administered 1 hour prior dental bleaching and extra doses of 4 mg were administered every 6 hours for 48 hours. Two office bleaching sessions were conducted in three applications fifteen minutes from HP 35% (Whiteness HP Maxx, FGM, Joinville, SC, Brazil), for both groups in accordance with the manufacturer’s directions. The TS was recorded on two scales: VAS (0-10) and numeric rating scale NRS (0-4), in different time points. The color evaluation were performed before, one week after first and second session of dental bleaching and one month after dental bleaching with a visual shade guide Vitapan Classical (Vita Zahnfabrik, Bad Säckingen, Germany), Vita Bleachedguide 3D-Master (Vita Zahnfabrik), and spectrophotometer Vita Easyshade (Vita Zahnfabrik). Data were analyzed using the suitable statistical tests (α = 0.05). There was no statistically significant difference between groups for the absolute risk of TS (p = 0.894), and not to the intensity of TS (p > 0.05). The intensity of the TS was greater in periods during bleaching and 1 h post-bleaching with reducing the intensity of the TS over time. Dental bleaching was effective in both groups, with no statistically significant difference when the color of the scales was assessed by Vitapan Classical (p > 0.642), Bleachedguide Vita 3D-Master (p > 0.775) and the spectrophotometer Vita Easyshade (p > 0.582). The use of dexamethasone does not reduce the absolute risk or the intensity of TS during the dental office bleaching. / O efeito adverso mais comum do clareamento dental é a sensibilidade dental (SD). O objetivo desse estudo foi determinar o efeito da dexametasona na SD, advinda do clareamento dental em consultório. Trata-se de um estudo clínico randomizado, paralelo, placebo-controlado, triplo-cego onde foram selecionados 63 voluntários segundo os critérios de inclusão/exclusão, os quais foram aleatorizados em dois grupos: placebo (GP) e dexametasona (GD). Os medicamentos (8 mg) foram administrados 1 h antes do clareamento dental e doses suplementares de 4 mg a cada 6 h durante 48 h. Foram realizadas 2 sessões de clareamento em consultório, com 3 aplicações de 15 min do gel de H202 35% (Whiteness HP Maxx, FGM, Joinville, SC, Brasil), para ambos os grupos, de acordo com a recomendação do fabricante. A SD foi registrada pelos voluntários em duas escalas: VAS (0-10) e escala numérica analógica (NRS 0-4), nos seguintes períodos: durante o clareamento dental, até 1h, 24h e 48h pós-clareamento. A cor foi registrada inicialmente e 1 mês após o clareamento dental, com as escalas visuais Vitapan Classical (Vita Zahnfabrik, Bad Säckingen, Alemanha) e Vita Bleachedguide 3D-Master (Vita Zahnfabrik), e pelo sistema CIELab através do espectrofotômetro Vita Easyshade (Vita Zahnfabrik). Os dados obtidos foram analisados através de testes estatísticos apropriados (α = 0,05). Não houve diferença estatisticamente significante entre os grupos para o risco absoluto da SD (p = 0,894), e nem para a intensidade da SD (p > 0,05). A intensidade da SD foi maior nos períodos durante o clareamento e 1 h pós-clareamento, com redução da intensidade da SD ao longo do tempo. O clareamento dental foi efetivo para ambos os grupos, não havendo diferença estatisticamente significante quando a cor foi avaliada através das escalas Vitapan Classical (p > 0,642), Vita Bleachedguide 3D-Master (p > 0,775) e pelo espectrofotômetro Vita Easyshade (p > 0,582). O uso da dexametasona não reduz o risco absoluto e nem diminuiu a intensidade da SD durante o clareamento dental em consultório
45

Penetração do peróxido de hidrogênio em diferentes concentrações na câmara pulpar e o manejo da sensibilidade pós-operatória em clareamento dental

Parreiras, Sibelli Olivieri 27 October 2017 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2017-10-27T12:19:28Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tese Sibelli.pdf: 2029440 bytes, checksum: b214f3a9a9cf1dd6ccca621c7ae4fae6 (MD5) / Made available in DSpace on 2017-10-27T12:19:28Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tese Sibelli.pdf: 2029440 bytes, checksum: b214f3a9a9cf1dd6ccca621c7ae4fae6 (MD5) Previous issue date: 2017-10-27 / Os objetivos deste estudo foram 1) quantificar a concentração do peróxido de hidrogênio (PH) de géis clareadores com diferentes concentrações do mesmo fabricante, 2) quantificar a concentração de PH na câmara pulpar em dentes com aplicação prévia de agentes dessensibilizantes ao clareamento de consultório e 3) avaliar o efeito de um gel dessensibilizante experimental na sensibilidade pósoperatória de pacientes submetidos a clareamento de consultório. Para os estudos 1 e 2, a quantificação de PH na câmara pulpar foi realizada por meio do método espectrofotométrico com a enzima horseradish peroxidase. No estudo 1, foram divididos aleatoriamente 90 dentes em nove grupos (n = 10) e submetidos a diferentes concentrações de gel clareador de mesmo fabricante, simulando o procedimento clareador caseiro e de consultório. No estudo 2, 50 dentes foram selecionados e os diferentes agentes dessensibilizantes: Desensibilize KF 2%, Mi Paste e Desensibilize Nano-P foram aplicados previamente ao clareamento de consultório com PH 35%. No estudo 3, 42 pacientes com os caninos com cor A2 ou mais escuros foram selecionados e divididos aleatoriamente em dois grupos: placebo (controle negativo) e tratamento. Os pacientes do grupo tratamento foram submetidos ao gel experimental a base de nitrato de potássio 5% e glutaraldeído 5% por 10 min previamente ao clareamento de consultório com PH 35%. A sensibilidade dental foi avaliada imediatamente, após 1 h, 24 h e 48 h do clareamento e registradas pelos próprios pacientes por meio das escalas numéricas de 5 pontos e visual analógica. A cor foi avaliada através da escala Vita classical, Vita Bleachedguide e espectrofotômetro Vita Easyshade (Vita Zahnfabrik, Bad Sackingen, Alemanha), inicialmente, 1 semana após cada sessão e um mês depois do término do procedimento. Os dados dos experimentos 1 e 2 foram avaliados por análise de variância (ANOVA) e teste de tukey para o contraste das médias ( = 0,05). Para a análise do risco de sensibilidade dental no estudo 3, os dados foram analisados por meio do teste Mc Nemar e a mudança de cor por teste t de Student ( = 0,05). Foi observado que a quantidade de PH que alcançou a câmara pulpar no grupo clareamento de consultório foi significativamente maior em comparação aos clareamentos caseiro (p = 0,65). Enquanto que os protocolos caseiros apresentaram resultados similares. O uso de agentes dessensibilizantes previamente ao clareamento de consultório reduziu a passagem de PH para a câmara pulpar, de forma que os dessensibilizantes Mi Paste e Nano-P tiveram menor concentração de PH na câmara pulpar (p < 0,001). Foi também possível observar que o risco de sensibilidade dentária do grupo gel dessensibilizante [31,7% (95% IC 19,6 – 46,9)] e para o grupo controle [70,7 (95% IC 55,5 – 82,3%) foram estatisticamente significante (p < 0,0001). Pode-se concluir que fatores como concentração do gel clareador e o uso prévio de agentes dessensibilizantes interferem na difusão do PH, porém a utilização do gel experimental à base de nitrato de potássio 5% e glutaraldeído 5% foi eficaz na redução da sensibilidade pós-operatória em pacientes submetidos a clareamento de consultório. / The objectives of this study were: 1) to evaluate the diffusion of hydrogen peroxide (HP) of bleaching gels with different concentrations from the same manufacturer, 2) quantify the HP concentration in the pulp chamber in teeth with prior application of desensitizing agents and 3) evaluate the effect of an experimental desensitizing gel on the postoperative sensitivity of patients undergoing in-office tooth bleaching. For studies 1 and 2, the quantification of HP in the pulp chamber was performed using the spectrophotometric method with the horseradish peroxidase enzyme. In study 1, 90 teeth were randomly divided into nine groups (n = 10) and submitted to different concentrations of whitening gel from the same manufacturer, simulating the home and in-office whitening procedure. In study 2, 50 teeth were selected at the different desensitizing agents: Desensibilize KF 2%, Mi Paste and Desensibilize Nano-P were applied prior to the office bleaching. In study 3, 42 patients with canines with A2 or darker color were selected and randomly divided into two groups: placebo (negative control) and treatment. Patients in the treatment group were submitted to 5% potassium nitrate and 5% glutaraldehyde gel for 10 min prior to bleaching with 35% hydrogen peroxide. The dental sensitivity was evaluated immediately, after 1 h, 24 h and 48 h of the bleaching and registered by the patients themselves through the numerical scales of 5 points and visual analog. The color was evaluated through the Vita classical, Vita Bleachedguide and Vita Easyshade spectrophotometer (Vita Zahnfabrik, Bad Sackingen, Germany), initially, 1 week after each session and one month after the end of the procedure. Data from experiments 1 and 2 were evaluated by analysis of variance (ANOVA) and tukey test for the means contrast ( = 0.05). For the analysis of the risk of dental sensitivity in study 3, the data were analyzed using the Mc Nemar test and the color change by Student's t-test ( = 0.05). It was observed that the amount of HP that reached the pulp chamber in the office bleaching group was significantly higher compared to home bleaching (p = 0.65). The home protocols presented similar results. The use of desensitizing agents prior to the office bleaching reduced the passage of HP to the pulp chamber, so that the desensitizers Mi Paste and Nano-P had lower HP concentrations in the pulp chamber (p < 0.001). It was also possible to observe that the risk of tooth sensitivity of the desensitizing gel group [31.7% (95% CI 19.6 - 46.9)] and for the control group [70.7 (95% CI 55.5 - 82.3%) were statistically significant (p < 0.0001). It can be concluded that factors such as concentration of the bleaching gel and the previous use of desensitizing agents interfere in the diffusion of PH, but the use of the experimental gel based on 5% potassium nitrate and 5% glutaraldehyde was effective in reducing post-operative in patients undergoing in-office tooth bleaching.
46

Avaliação histológica e imuno-histoquímica do complexo dentino-pulpar em modelo de recessão gengival com diferentes formulações de biovidros nanoparticulados para a obliteração de túbulos dentinários – estudo em ratos

Dalmolin, Ana Cláudia 22 February 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-07-31T12:54:31Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Ana Cláudia Dalmolin.pdf: 4507654 bytes, checksum: 94b0e5d7e5b5768e1913e17076d5138e (MD5) / Made available in DSpace on 2018-07-31T12:54:31Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Ana Cláudia Dalmolin.pdf: 4507654 bytes, checksum: 94b0e5d7e5b5768e1913e17076d5138e (MD5) Previous issue date: 2018-02-22 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A hipersensibilidade dentinária cervical (HSDC) ocorre devido à exposição dentinária da região cervical por fatores como perda de minerais do esmalte ou da própria dentina, ou por recessão gengival. A exposição dos túbulos dentinários, conforme a teoria hidrodinâmica, facilita a transmissão de estímulos desde a superfície dentinária até a polpa. Os biovidros são biomateriais que inicialmente foram desenvolvidos para reparo e regeneração óssea, e que passaram a ser empregados também no tratamento da HSDC. Considerando a falta de compreensão quanto a condição pulpar, e a lacuna existente entre os biomateriais e a eficácia no tratamento, foi proposta a utilização de um modelo in vivo em ratos, em que, através da exposição dentinária cervical, pudesse demonstrar o processo neuroinflamatório no tecido pulpar, bem como testar e avaliar os efeitos de duas formulações de biovidros experimentais para a obliteração de túbulos dentinários. Desta forma, foram utilizados 29 ratos Wistar machos, os quais receberam cirurgias de indução de recessão gengival, com instalação de dispositivo de permanência temporária, assim promovendo a manutenção da condição de túbulos dentinários cervicais expostos. Prosseguiu-se com a aplicação dos tratamentos de acordo com os grupos de estudo: Naive (N) - sem recessão gengival e sem tratamento; Sham (S) – com recessão gengival e sem tratamento; Verniz cavitário (V) - recessão gengival e tratamento com verniz cavitário; Biosilicato® (BV-BS) - recessão gengival e tratamento com Biosilicato®; Biovidro de estrôncio (BV-Sr) - recessão gengival e tratamento com biovidro de estrôncio; Biovidro de potássio (BV-K) - recessão gengival e tratamento com biovidro de potássio. Os tratamentos foram aplicados sobre a superfície dentinária exposta dos primeiros molares superiores esquerdos, a cada 4 dias durante 28 dias, totalizando 7 aplicações. Realizou-se processamento histológico das hemimaxilas esquerda e direita, com posterior coloração de hematoxilina e eosina (HE) para avaliar alterações no complexo dentino-pulpar, além de coloração imunohistoquímica (IHQ) para identificação de substância P (SP). Os resultados apontaram que não houve diferenças significativas (p>0,05, teste de Kruskal-Wallis) entre os grupos, considerando os critérios para alterações dentino-pulpares; tampouco foram observadas diferenças na imuno-marcação para SP. Concluiu-se que não há alterações no complexo dentino-pulpar ou aumento de substância P em dentes com exposição radicular e túbulos expostos em ratos. Nas condições em que foram aplicados, os biovidros experimentais não são capazes de causar danos na polpa dental. No entanto, sugere-se a continuidade das pesquisas, com a avaliação de outros parâmetros no modelo animal para a melhor compreensão do mecanismo da HSDC. / Cervical dentin hypersensitivity (CDH) occurs due to dentin exposure of the teeth’s cervical region by factors such as loss in enamel or dentin minerals, or gingival recession. Dentin tubules exposure, according to the hydrodynamic theory, facilitates the transmission of stimuli from the dentin surface to the pulp. Bioactive glasses are biomaterials that were initially developed for bone repair and regeneration, but they could also be used for CDH treatment. There is no understanding about pulp conditions when dentin is exposed, neither about the efficacy of biomaterials used to CDH treatment. It was proposed an in vivo model of cervical dentin exposure in rats. This in vivo model demonstrates the pulp neuroinflammatory process and tests the efficacy of Biosilicate® and of two others experimental formulations of bioglasses in dentinal tubules obliteration. Thus, 29 male Wistar rats were submitted to exposure of the dentinal tubules, through gingival recession surgery. A temporary device was installed to keep the dentinal tubules exposure. Then, the treatments were applied over the exposed dentin surface of the upper left first molars every 4 days during a 28 days period, with the total of 7 applications. The treatments were applied according to the study groups: Naive (N) – no recession and no treatment; Sham (S) – recession but no treatment; Cavity varnish (V) – gingival recession and treatment with varnish; Biosilicate® (BV-BS) – gingival recession and treatment with Biosilicate®; Strontium bioglass (BV-Sr) – gingival recession and treatment with strontium bioglass; Potassium bioglass (BV-K) – gingival recession and treatment with potassium bioglass. The dentin-pulp complex changes and investigation of substance P (SP) were evaluated through hematoxylin and eosin (HE) and immunohistochemical (IHC) stainings after histological processing and paraffin sectioning of the left and right hemi-maxilae. The results showed that there were no significant differences (p>0.05, Kruskal-Wallis test) among the groups considering the conditions of the dentin-pulp complex. No differences were observed in immunostaining for SP. It was concluded that teeth with cervical root exposition and opened tubules in rats do not have changes in the dentinpulp complex or in the pattern of immunotracing for SP. Experimental bioactive glasses are not capable of causing damage to the dental pulp under the conditions in which it was applied. Nevertheless, new animal model studies could be conducted using others histological and immunohistochemical parameters in order to understand the mecanisms of the CDH.
47

Tratamento da hipersensibilidade dentinária com verniz de fluoreto de sódio a 5% terapia com laser de baixa intensidade e aplicação associada : estudo clínico, controlado, randomizado, duplo cego, boca dividida. /

Paixão, Aline Kataki. January 2018 (has links)
Orientador: Andrea Carvalho De Marco / Coorientador: Dimas Renó de Lima / Banca: Symone Cristina Teixeira / Banca: Cibelle Barbosa Lopes / Resumo: A hipersensibilidade dentinária é uma das complicações mais comuns entre os pacientes após o tratamento periodontal. Recentemente a terapia com o uso de laser de baixa intensidade foi introduzida como uma nova modalidade de tratamento e tem proporcionado resultados benéficos. Foi realizado um estudo clínico controlado, randômico, duplo-cego, de boca dividida com o objetivo de comparar a efetividade do uso do verniz tópico Fluoreto de sódio 5%, do Laser GaAlAs 780 nm e da combinação do Fluoreto de sódio 5% e o Laser GaAlAs 780 nm para o tratamento de hipersensibilidade dentinária. Os Grupos foram divididos em Grupo Controle (C), Grupo Fluoreto de sódio 5% (F), Grupo Laser GaAlAs 780 nm (LLLT), e o Grupo Fluoreto de sódio 5% + Laser GaAlAs 780 nm (F+LLLT). A aplicação do verniz foi realizada com pinceis do tipo "microbrush", e para cada elemento dental cinco pontos receberam a LLLT, com dose de 52,5 J/cm2 (70mW e 30 segundos) ou 2,1 J por ponto; 6 segundos por ponto. A hipersensibilidade primária foi registrada pela escala analógica visual (VAS: 0-10) para quantificar a dor subjetiva após estímulo com "spray de gelo" no baseline, e após o tratamento nos intervalos de 24 horas e 30 dias. Todos os dados foram analisados estatisticamente pela análise de variância ANOVA. Para cada um dos três tempos de avaliação foi efetuada uma comparação entre os 4 grupos (por meio da ANOVA oneway) com complementação pelos testes de Tukey e Bartlett a fim de verificar as diferenças estatísticas e... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Dentin hypersensitivity is one of the most common complications among patients after periodontal treatment. Recently the low level laser therapy has been introduced as a new treatment modality and has provided beneficial results. A split-mout, double-blind, randomized, controlled clinical trial was conducted with the aim of compare the effectiveness of the topical varnish 5% Sodium Fluoride, Laser GaAlAs 780 nm and the combination of 5% Sodium Fluoride and the Laser GaAlAs 780 nm for the treatment of dentin hipersensitivity. The groups were divided in Control Group (C), Sodium Fluoride at 5% Group (F), Laser Group GaAlAs 780 nm (LLLT), and Sodium Fluoride at 5% Group + GaAlAs Laser 780 nm (F + LLLT). The application of the varnish was realized with "microbrush", and for each dental element, five points was received LLLT. The dose was 52.5 J / cm2 (70mW and 30 seconds) or 2.1 J per point, 6 seconds per point. Primary hypersensitivity was be recorded by visual analogue scale (VAS: 0-10) to quantify subjective pain after the stimulus with "ice spray" at baseline, and after treatment at 24-hour and 30-day intervals. All data was analyzed statistically by analysis of variance ANOVA. For each of the three evaluation times a comparison was made between the 4 groups (through the oneway ANOVA) with complementation by the Tukey's and Bartlett's tests in order to verify the statistical differences between groups. The level of significance will be 5%. After statistical analysis the resul... (Complete abstract click electronic access below) / Mestre
48

Eficácia de um dentifrício contendo partículas clareadoras no tratamento da descoloração dentária: ensaio clínico randomizado

Sousa, Jossaria Pereira de 28 October 2013 (has links)
Made available in DSpace on 2015-05-14T12:56:03Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2131747 bytes, checksum: 29f26f35febbc01863dacd7a6d17e909 (MD5) Previous issue date: 2013-10-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this clinical trial was to evaluate the efficacy, safety and acceptability of whitening toothpaste containing blue covarine in the treatment of tooth discoloration. It is a parallel controlled double-blind randomized clinical trial which followed the guidelines published by CONSORT. Seventy-five subjects with shade mean C1 or darker for the six maxillary anterior teeth were randomized in three treatment groups (n= 25): G1- conventional fluoridated toothpaste, G2- whitening toothpaste containing a silica system and blue covarine, and G3- bleaching with 10% carbamide peroxide. Subjects from G1 and G2 were instructed to brush their teeth for 90 seconds, twice per day during 2 weeks. Subjects from G3 used 10% carbamide peroxide gel in a tray for 4h/night also for two weeks. Shade evaluations were done with a spectrophotometer (Vita Easyshade® Advance) at baseline, after first application and at 2 and 4 weeks. Subjects perception about tooth color appearance was assessed by a visual analog scale (VAS). Tooth sensitivity (TS) and gingival irritation (GI) were measured daily using a scale ranging from 1 (no sensitivity) to 5 (severe sensitivity) during three weeks, and the acceptability of products was measured with a questionnaire that included questions about subjects opinion regarding the treatment regimen. At all evaluations periods, there was not statistical difference between G1 and G2 groups considering the CIEL*a*b* color parameters (p> 0.3) or the tooth shade means (p> 0.7). At 2-week evaluation, &#916;E* value for G3 was statistically higher (9.2) than for G1 (2.3) and G2 (2.1) (p= 0.0001). G1 and G2 reported a major dissatisfaction with tooth color appearance than G3 (p= 0.0001).Tooth sensitivity and gingival irritation were reported by 12% of subjects from G2, while the same symptoms were perceived by 84% and 80% of G3. At first and second weeks of treatment, G2 experienced tooth sensitivity and gingival irritation similarly to G1 group and statistically lower than G3 (p< 0.01). It was observed a negative correlation between TS/GI and day of evaluation (r= -0.08 and r= -0.91) in G3. Within the limitations of this study, it could be concluded that the whitening toothpaste containing a silica system and blue covarine resulted in no significant changes on tooth color, as the conventional toothpaste. These groups did not show whitening effect as the group treated with 10% carbamide peroxide. However, all could be considered safe and acceptable to be used daily for a short term. / O objetivo do presente estudo foi avaliar a eficácia, segurança e aceitabilidade de um dentifrício branqueador contendo partículas azuis no tratamento da descoloração dentária. Trata-se de um ensaio clínico randomizado duplo-cego controlado e paralelo, cujo delineamento seguiu o guia publicado pelo CONSORT. Setenta e cinco participantes com média de cor C1 ou mais escura para os seis dentes ântero-superiores foram randomizados em três grupos de tratamento (n=25): G1- dentifrício fluoretado convencional, G2- dentifrício branqueador contendo um sistema de sílica e partículas azuis, e G3- clareamento dentário com peróxido de carbamida a 10%. Os participantes dos grupos G1 e G2 foram instruídos a escovarem seus dentes por 90 segundos, duas vezes ao dia durante duas semanas. Os participantes do grupo G3 usaram o gel clareador peróxido de carbamida a 10% em moldeira personalizada 4h/noite também por duas semanas. Avaliações de cor dentária foram realizadas por meio de espectrofotômetro digital (Vita Easyshade® Advance) nos tempos baseline, após primeira aplicação e com duas e quatro semanas. A percepção estética dos participantes quanto à aparência da cor dentária foi avaliada por meio de escala analógica visual (EAV). Sensibilidade dentinária (SD) e Irritação Gengival (IG) foram mensuradas usando uma escala que variou de 1 (nenhuma sensibilidade) a 5 (severa sensibilidade) durante três semanas, e a aceitabilidade dos produtos foi avaliada com um questionário o qual incluiu questões sobre a opinião dos participantes quanto aos regimes de tratamento propostos. Em todos os períodos de avaliação não houve diferença estatisticamente significante entre os grupos G1 e G2, considerando os parâmetros de cor do CIEL*a*B* (p> 0,3) e as medidas de cor da escala Vita (p>0,7). Na segunda semana de avaliação, o valor de &#916;E* para o G3 foi estatisticamente maior (9,2) do que para o G1 (2,3) ou para G2 (2.1) (p=0,0001). Sensibilidade dentinária e irritação foram reportadas por 12% dos participantes do G2, enquanto os mesmos sintomas foram percebidos por 84% e 80% do G3. Na primeira e segunda semana de tratamento, G2 apresentou sensibilidade gengival e irritação gengival similares ao grupo G1 e estatisticamente menores que o G3 (p< 0,01). Observou-se uma correlação negativa entre SD/IG e dia de avaliação (r= -0,08 e r= -0,91) no grupo G3. Dentro das limitações desse estudo, pôde-se concluir que o dentifrício branqueador contendo um sistema de sílica e partículas azuis resultou em nenhuma mudança significante na cor dentária, assim como o dentifrício convencional. Tais grupos não mostraram efeito clareador como o grupo tratado com peróxido de carbamida a 10%. Entretanto, todos foram considerados seguros e aceitáveis para serem utilizados diariamente em um curto período de tempo.
49

Avaliação de protocolos de clareamento através de ensaios clínicos randomizados, revisões sistemáticas e meta-análises / Evaluation of clinical protocols for dental bleaching through randomized clinical trials, systematic reviews and meta-analysis

Maran, Bianca Medeiros 08 June 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-07-24T17:00:57Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Biancamedeirosmaran.pdf: 3971508 bytes, checksum: 0188e5172bf200ce9a76e85bec1691c9 (MD5) / Made available in DSpace on 2018-07-24T17:00:57Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Biancamedeirosmaran.pdf: 3971508 bytes, checksum: 0188e5172bf200ce9a76e85bec1691c9 (MD5) Previous issue date: 2018-06-08 / Objetivos: Avaliar a eficácia e sensibilidade dental (SD) utilizando agentes dessensibilizantes incorporados ao gel no clareamento caseiro (1) e em consultório (2), no uso da ativação com luz no clareamento em consultório com alta e baixa concentração de peróxido de hidrogênio (3 e 4); no clareamento combinado (consultório e caseiro) vs. isolado (5), além de avaliar a conformidade dos estudos clínicos randomizados (ECRs) de clareamento com o CONSORT e o risco de viés desses estudos pela ferramenta Cochrane (6). Metodologias: Para este trabalho, foram feitos seis estudos: dois ECRs e quatro revisões sistemáticas (RSs), sendo que o estudo (4) foi uma RS de comparação mista de tratamentos (MTC). Os ECRs (1 e 2) foram triplo-cegos, boca-dividida e o tratamento clareador foi realizado em 120 pacientes livres de cárie, conforme critérios de inclusão e exclusão, sendo 60 em cada estudo. Os agentes dessensibilizantes incorporados ao gel foram, 3% de nitrato de potássio e 0,2% de fluoreto de sódio (1), e 5% de nitrato de potássio (2). No estudo (1) uma moldeira foi usada três horas diariamente por 21 dias, no estudo (2) foi feita uma aplicação única de 50 minutos em duas sessões com intervalo de sete dias entre elas. Foram avaliados o risco absoluto e a intensidade da SD por meio das escalas visual analógica 0-10 cm e de classificação numérica 0-4 durante três semanas no estudo (1) e durante e até 48 horas após cada sessão no estudo (2); a alteração de cor foi registrada utilizando as escalas de cor Vita Classical, Bleachedguide (ΔUEV) e espectrofotômetro Easyshade (ΔE*) antes, durante e após 30 dias do término de cada tratamento. O risco absoluto e a intensidade da SD foram avaliadas pelos testes de McNemar e Wilcoxon Signed Rank, respectivamente (α = 0,05), a eficácia do clareamento foi avaliada pelos testes de Wilcoxon Signed Rank (ΔUEV) e teste t para dados pareados (ΔE*) (α = 0,05). Nas RSs (3-6) foram feitas buscas por termos específicos sobre o tema em diferentes bases de dados e literatura cinzenta. O risco de viés foi avaliado usando a ferramenta de Colaboração Cochrane. Meta-análises foram conduzidas para mudança de cor (ΔE*, ΔSGU), risco e intensidade de SD, usando modelo de efeitos aleatórios. A heterogeneidade foi avaliada com o teste Q de Cochran e a estatística I2. A qualidade de evidência (GRADE) foi avaliada nos estudos (3) e (5). Resultados: No estudo (1), não houve diferenças entre os grupos na cor, no risco e intensidade da SD (p > 0,05), já no estudo (2) foram observadas diferenças apenas na redução da intensidade da SD para o grupo com agente dessensibilizante nas primeiras 24 horas (p < 0,01). Nas RSs após a busca dos estudos, restaram 21 (3), 28 (4), 11 (5), 185 (6) ECRs. Na RS (3) não houve diferença na cor e na SD (p > 0,05), e a qualidade de evidencia foi graduada como moderada para ΔE* e risco de SD, e muito baixa e baixa para ΔUEV e intensidade da SD, respectivamente. Na RS de MTC (4), não houve diferença na cor sem o uso da luz ou com diferentes fontes de luz usadas. Na RS (5) não houve diferença na cor no clareamento combinado vs. em consultório (p > 0,05) e não foram obtidos dados disponíveis para avaliação do risco e intensidade da SD; no clareamento combinado vs. caseiro não foram observadas diferenças para ΔE*, ΔSGU e risco de SD, porém, menor intensidade de SD foi detectada no clareamento caseiro isolado com diferença de média padronizada de 0,86 (IC 95% 0,31-1,41), e a qualidade de evidência foi graduada como moderada para alteração de cor em ΔE*, e baixa ou muito baixa para as demais análises. Na RS (6) na classificação de adesão ao CONSORT dos estudos, a média geral foi 16,7 ± 5,4 pontos (de 32 pontos no total) e apenas 7,6% foram julgados como baixo risco de viés. Conclusões: A incorporação dos agentes dessensibilizantes nos géis clareadores usados neste trabalho não afetou a cor e não reduziu a SD no clareamento caseiro (1), porém diminuiu a intensidade da SD no clareamento em consultório (2). O uso da ativação com luz no clareamento em consultório não melhorou a cor nem afetou a SD independente da concentração de peróxido de hidrogênio utilizada (3) e igualmente não afetou a cor no estudo (4). No clareamento combinado vs. isolado (5), baixa intensidade de SD foi encontrada no clareamento caseiro, quando este foi realizado isoladamente. E no estudo (6) concluiu-se que a adesão ao CONSORT em ECRs de diferentes técnicas de clareamento é baixa e possuem alto risco de viés. / To evaluate efficacy and tooth sensitivity (TS) through the use of desensitizing agents incorporated into the gel in the at-home (1) and in the in-office bleaching (2), in the use of light activation in the in-office bleaching with high and low hydrogen peroxide concentration (3 and 4); in combined (at-home and in-office) vs. isolated bleaching (5), in addition to assessing the conformity of the randomized clinical trials (RCTs) of bleaching with CONSORT and the risk of bias of these studies by the Cochrane tool (6). Methodologies: Six studies: two RCTs and four systematic reviews (SRs) were made for this work, the study (4) was a mixed-treatment comparison (MTC). The RCTs (1 and 2) were triple-blind, split-mouth and the bleaching treatment was performed on 120 caries-free patients, according to inclusion and exclusion criteria, of which 60 were in each study. The desensitizing agents incorporated into the gel were 3% potassium nitrate and 0.2% sodium fluoride (1), and 5% potassium nitrate in study (2). In study (1) a tray was used three hours daily for 21 days, in study (2) a single application of 50 minutes was made in two sessions with 7-days intervals between them. Were assessed the absolute risk and the intensity of TS using the 0-10 cm visual analog and 0-4 numerical rating scales for 21 days in the study (1) and during 48 hours after each study session (2); the color change was recorded using the Vita Classical, Bleachedguide (ΔSGU) and Easyshade spectrophotometer (ΔE*) color scales before, during and after 30 days of the end of each treatment. The absolute risk and intensity of TS were assessed by the McNemar and Wilcoxon Signed Rank tests, respectively (α = 0.05), the color change was assessed by Wilcoxon Signed Rank (ΔSGU) and t-test for paired data (ΔE*) (α = 0.05). In the SRs (3-6) were searched for specific terms about the topic on databases and grey literature. The risk of bias was assessed using the Cochrane Collaboration tool. Meta-analysis were conducted for color change (ΔE*, ΔSGU), risk and intensity of TS using random effects model. Heterogeneity was assessed with the Cochran Q test and the I2 statistic. The quality of evidence (GRADE) was evaluated in the studies (3) and (5). Results: In the study (1), there were no differences between groups in color, risk and intensity of SD (p > 0.05); in the study (2) differences were observed only in the reduction the intensity of TS for the group with desensitizing agent in the first 24 hours (p < 0.01). In the SRs after the search of the studies, there were 21 (3), 28 (4), 11 (5), 185 (6) RCTs. In SR (3) there were no differences in color and TS (p > 0.05), and the quality of evidence was graded as moderate for ΔE* and risk of TS, and very low and low for ΔSGU and intensity of TS, respectively. In MTC SR (4), there were no differences in color without the use of light or with different light sources used. In SR (5) there was no difference in color in the combined vs. in-office bleaching (p > 0.05), and no data were available to assess the risk and intensity of TS; in combined vs. at-home bleaching no differences were observed for ΔE*, ΔSGU and risk of TS; however, lower intensity of TS was detected in the sole at-home bleaching with a standardized mean difference of 0.86 (95% CI, 0.31-1.41); and the quality of evidence was graded as moderate for color change in ΔE*, and low or very low for the other analysis. In the SR (6) in the CONSORT classification of the studies, the general mean was 16.7 ± 5.4 points (out of 32 points in total) and only 7.6% were judged as low risk of bias. Conclusions: The incorporation of the desensitizing agents in the bleaching gels used in this study did not affect the color and did not reduce the TS in the at-home bleaching (1), but it decreased the intensity of TS in the in-office bleaching (2). The use of light activation in the in-office bleaching did not improve color or affect TS regardless of the concentration of hydrogen peroxide used (3) and also did not affect color in the study (4). In combined vs. isolated bleaching (5), low intensity of TS was found in sole at-home bleaching. And in the study (6) it was concluded that adherence to CONSORT in RCTs of different bleaching techniques is low and with high risk of bias.

Page generated in 0.1277 seconds