• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 65
  • 46
  • 38
  • 13
  • 7
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 218
  • 46
  • 32
  • 29
  • 22
  • 21
  • 19
  • 18
  • 18
  • 17
  • 16
  • 16
  • 15
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Založení stavby River Garden III v Praze / Foundation design of River Garden III in Prague

Malinský, Martin January 2015 (has links)
The topic of this master's thesis are the design of ensuring foundation pit and foundation of administrative building in Prague. In the vicinity of foundation pit is situated the river Vltava, which directly influences the ground water level at the job site. During construction, it is necessary to envisage the possibility of occurrence of the old building structures of docks.
202

Interakce plazmatu s kapalnou fází / Study of Plasma - Liquid Interactions

Němcová, Lucie January 2013 (has links)
Disertační práce se zabývá detailním studiem vlastností různých elektrických výbojů generovaných ve vodných roztocích. Tyto výboje se staly v posledním desetiletí velmi populárním tématem, a to zejména díky mnoha praktickým využitím jako například v biomedicíně, čištění odpadních vod, ekologii nebo nanoinženýrství. Studium je zaměřeno na generaci peroxidu vodíku, jakožto jednu z nejvýznamnějších částic generovaných právě elektrickými výboji v kapalinách. Pro první část této práce byla využita speciální výbojová komora zkonstruovaná na Fakultě chemické Vysokého Učení Technického v Brně. Komora byla rozdělena tenkou diafragmovou přepážkou na dvě poloviny, přičemž uvnitř přepážky se nacházela malá dírka. V každé části komory se nacházela jedna elektroda, a obě dvě části komory byly vyplněny kapalinou. Ze zdroje bylo do kapaliny aplikováno vysokofrekvenční napětí (1 a 2 kHz), které tak vlastně upravovalo roztok chloridu sodného (1.5 l). Bylo zjištěno, že tento druh napětí, v porovnání s DC, nezpůsobuje nežádoucí přehřívání roztoku (počáteční vodivost 100 - 800 S/cm) během jeho úpravy při zachování účinnosti produkce peroxidu. Experimentální aparatura pro druhou část práce byla sestavena na Gentské Univerzitě v Belgii. Stejnosměrný výboj byl generován v bublinách plynů (He, Ar, N2, vzduch) v prostředí vodných roztoků. Byla studována generace peroxidu vodíku a odbourávání organických barviv přítomných ve zkoumaném roztoku. Ke generaci peroxidu vodíku byl použit roztok NaH2PO4 . 2H2O (5 microS/cm, V= 750 ml), ke zkoumání rozkladu barviv byly použity roztoky organických barviv Direct Red 79 (20 mg/l) a Direct Blue 106 (20 mg/l, V= 750 ml). Minimální koncentrace peroxidu vodíku byla naměřena při aplikaci proudu 10 mA, zatímco maximální koncentrace peroxidu vodíku byla zaznamenána při použití proudu 30 mA. Rozklad organických barviv vykazoval stejné vlastnosti. Čím vyšší byla dodávaná energie, tím více barviva se odbouralo. Třetí část práce probíhala ve spolupráci s Queen's University of Belfast, Centrum for Plasma Physics, UK. K realizaci experimentů bylo využito vysokofrekvenčního plazmového skalpelu (Arthrocar). Bylo zjištěno, že hodnota koncentrace peroxidu vodíku dosahovala maxima v roztocích s nepatrným přídavkem alkoholu (0.25 %). Celkem byly studovány čtyři 0.15 M roztoky BaCl2, Na2CO3, KCl a NaCl (V= 20 ml), jejichž počáteční vodivost se pohybovala kolem 13 mS/cm. Z výsledků bylo patrné, že největší rozdíl hodnot pH byl zaznamenán u roztoků s přídavkem ethanolu. V optických emisních spektrech byly identifikovány především radikály OH, které jsou prekurzory peroxidu vodíku. Výsledky ukázaly, že plazma v takovémto roztoku je stále tvořeno, což může být považováno za první krok generace plazmatu v organických sloučeninách. Poslední část práce byla zaměřena na tzv. mikroplazmatický jet v přímém kontaktu s kapalnou fází. Tato experimentální práce byla realizována na pracovišti Nanotechnology & Integrated Bio-Engineering Centre (NIBEC), University of Ulster, UK během studijní stáže. Jako vodivé médium byl použit roztok trihydrátu kyseliny chlorozlatité s různou počáteční vodivostí. Zajímavým zjištěním je fakt, že při tomto druhu měření bylo generováno stabilní plazma i při velmi malém výbojovém proudu (0.05 a 0.2 mA), a tedy i peroxid vodíku vznikal při velmi malé vstupní energii, což může být považováno za velmi dobrý výsledek.
203

Activité électrique diaphragmatique au cours du sevrage ventilatoire après insuffisance respiratoire aigue / Diaphragm electrical activation during weaning from mechanical ventilation after acute respiratory failure

Rozé, Hadrien 12 December 2014 (has links)
Le contrôle de la ventilation procède d’une interaction complexe entre des efférences centrales à destination des groupes musculaires ventilatoires et des afférences ventilatoires provenant de mécano et de chémorécepteurs. Cette commande de la ventilation s’adapte en permanence aux besoins ventilatoires. L’activation électrique du diaphragme (EAdi) informe sur la commande ventilatoire, la charge des muscles respiratoires, la synchronie patient-ventilateur et l’efficacité de la ventilation des patients de réanimation. L’utilisation inadaptée d’un mode deventilation spontanée avec une sur ou sous-assistance peut entrainer des dysfonctions diaphragmatiques, des lésions alvéolaires et des asynchronies. La première étude a permis de cibler l’assistance du mode NAVA en fonction de l’EAdi enregistrée lors d’un échec de test de sevrage. Nous avons observé une augmentation quotidienne de cette EAdi au cours du sevrage jusqu’à l’extubation. La deuxième étude a montré que cette augmentation n’est pas associée à une modification de l’efficacité neuro-ventilatoire lors du test de sevrage, possiblement en rapport avec l’inhibition d’une sédation résiduelle. La troisième étude a montré l’importance de l’inhibition de cette sédation résiduelle par midazolam sur l’EAdi et le volume courant au début du sevrage ainsi que la corrélation qui existe entre les deux. Une dernière étude a montré l’absence d’augmentation du volume courant sous NAVA chez des patients transplantés pulmonaires aux poumons dénervés sans réflexe de Herring Breuer par rapport à un groupe contrôle. Par ailleurs le volume courant sous NAVA était corrélé à la capacité pulmonaire totale. Ces études ont montré l’intérêt du monitorage l’EAdi dans le sevrage. / The control of breathing results from a complex interaction involving differentrespiratory centers, which feed signals to a central control mechanism that, in turn, provides outputto the effector muscles. Afferent inputs arising from chemo- and mechanoreceptors, related to thephysical status of the respiratory system and to the activation of the respiratory muscles, modulatepermanently the respiratory command to adapt ventilation to the needs. Diaphragm electricalactivation provides information about respiratory drive, respiratory muscle loading, patientventilatorsynchrony and efficiency of breathing in critically ill patients. The use of inappropriatelevel of assist during spontaneous breathing with over or under assist might be harmful withdiaphragmatic dysfunction, alveolar injury and asynchrony. The first study settled NAVA modeaccording to the EAdi recorded during a failed spontaneous breathing trial (SBT). An unexpecteddaily increase of EAdi has been found during SBT until extubation. The second study did not findany increase of the neuroventilatory efficiency during weaning, possibly because of residualsedation. A third study described the inhibition of residual sedation on EAdi and tidal volume at thebeginning of the weaning, and the correlation between them. The last study did not find anyincrease of tidal volume under NAVA after lung transplantation, with denervated lung withoutHerring Breuer reflex, compared to a control group. Moreover tidal volume under NAVA wascorrelated to total lung capacity. These studies highlight the interest of EAdi monitoring duringweaning.
204

Modelování podzemních stěn pomocí časově závislého elasto-plastického materiálového modelu / Modelling of diaphragm walls using time-dependent elasto-plastic material model

Šindelářová, Daniela January 2022 (has links)
The goal of this thesis was the verification of the advanced time-dependent elasto-plastic material model for modeling diaphragm walls. Currently, this type of construction is solved usually with a combination of linear-elastic volume and plate elements. To express time-dependent behaviour, there are both, volume and plate, elements active in short-term conditions, then only volume elements in long-term conditions, while plate elements are deactivated. In this thesis, the Shotcrete material model, which can capture the time-dependent behaviour without combining two types of construction elements, is used. First, a theory of time-dependent behaviour is presented and a design of concrete structures by Eurocode 2 is discussed. Next, the Shotcrete material model is described, then used for modeling a biaxial test and calibration of compression and bending test. Following the gained knowledge, a real boundary value problem of deep excavation supported by diaphragm walls with the strut was solved. To calculate values of the internal forces and horizontal deformation in diaphragm walls, three types of material models are used.
205

Diafragmový výboj v roztocích organických barviv / Diaphragm discharge in organic dye solutions

Pajurková, Jana January 2010 (has links)
This Diploma thesis was focused on the degradation of dyes Saturn Red L4B (Direct Red 79) and Saturn Blue LB (Direct Blue 106) by DC diaphragm discharge (DC-DD). Supplied power was between 160 and 180 W. Conductivity and pH were changing at each electrode area during the DC diaphragm discharge, therefore the effect of pH and conductivity changes on the dye solution itself were examined. All samples were measured by UV-VIS spectrometer in the wavelength range of 300–800 nm. No significant dependence of dye absorption spectra on conductivity was observed, while pH significantly affected the absorption curves of dyes. Ageing of dye spectra showed significant changes of Saturn Red L4B. Next task was the comparison of dyes destruction efficiency by DC-DD, audiofrequency diaphragm discharge (AF-DD) and electrolysis. Dye decomposition by AF-DD was not observed at set conditions (voltage of 80–120 V, current of 2.2 A and frequency of 2 kHz). In the case of DC diaphragm discharge the electrolysis played an important role. Decomposition efficiency of the dyes by electrolysis was up to 15 %. The pumping effect in the DC diaphragm discharge was also investigated. Although the individual electrode areas were linked only by a small pinhole in a nonconductive barrier (the pinhole diameter of 0.3 mm), solutions of the anode and cathode compartment interacted with each other up to 10 %. Finally, the degradation products of Saturn Red L4B treated by DC-DD in two electrodes parts are also described. Decomposition products were determined by high performance liquid chromatography (HPLC) combined with the mass spectrometer.
206

Le mode de ventilation neurally adjusted ventilatory assist (NAVA) est faisable, bien toléré, et permet la synchronie entre le patient et le ventilateur pendant la ventilation non invasive aux soins intensifs pédiatriques : étude physiologique croisée

Ducharme-Crevier, Laurence 08 1900 (has links)
Introduction: La ventilation non invasive (VNI) est un outil utilisé en soins intensifs pédiatriques (SIP) pour soutenir la détresse respiratoire aigüe. Un échec survient dans près de 25% des cas et une mauvaise synchronisation patient-ventilateur est un des facteurs impliqués. Le mode de ventilation NAVA (neurally adjusted ventilatory assist) est asservi à la demande ventilatoire du patient. L’objectif de cette étude est d’évaluer la faisabilité et la tolérance des enfants à la VNI NAVA et l’impact de son usage sur la synchronie et la demande respiratoire. Méthode: Étude prospective, physiologique, croisée incluant 13 patients nécessitant une VNI dans les SIP de l’hôpital Ste-Justine entre octobre 2011 et mai 2013. Les patients ont été ventilés successivement en VNI conventionnelle (30 minutes), en VNI NAVA (60 minutes) et en VNI conventionnelle (30 minutes). L’activité électrique du diaphragme (AEdi) et la pression des voies aériennes supérieures ont été enregistrées pour évaluer la synchronie. Résultats: La VNI NAVA est faisable et bien tolérée chez tous les enfants. Un adolescent a demandé l’arrêt précoce de l’étude en raison d’anxiété reliée au masque sans fuite. Les délais inspiratoires et expiratoires étaient significativement plus courts en VNI NAVA comparativement aux périodes de VNI conventionnelle (p< 0.05). Les efforts inefficaces étaient moindres en VNI NAVA (résultats présentés en médiane et interquartiles) : 0% (0 - 0) en VNI NAVA vs 12% (4 - 20) en VNI conventionnelle initiale et 6% (2 - 22) en VNI conventionnelle finale (p< 0.01). Globalement, le temps passé en asynchronie a été réduit à 8% (6 - 10) en VNI NAVA, versus 27% (19 - 56) et 32% (21 - 38) en périodes de VNI conventionnelle initiale et finale, respectivement (p= 0.05). Aucune différence en termes de demande respiratoire n’a été observée. Conclusion: La VNI NAVA est faisable et bien tolérée chez les enfants avec détresse respiratoire aigüe et permet une meilleure synchronisation patient-ventilateur. De plus larges études sont nécessaires pour évaluer l’impact clinique de ces résultats. / Introduction: The need for intubation after noninvasive ventilation (NIV) failure is frequent in the pediatric intensive care unit (PICU). One reason is patient-ventilator asynchrony during NIV. Neurally adjusted ventilatory assist (NAVA) is a mode of ventilation controlled by the patient’s neural respiratory drive. The aim of this study was to assess the feasibility and tolerance of NIV-NAVA in children and to evaluate its impact on synchrony and respiratory effort. Methods: This prospective, physiologic, crossover study included 13 patients requiring NIV in the PICU of Sainte-Justine’s Hospital from October 2011 to May 2013. Patients were successively ventilated in conventional NIV as prescribed by the physician in charge (30 minutes), in NIV-NAVA (60 minutes), and again in conventional NIV (30 minutes). Electrical activity of the diaphragm (EAdi) and airway pressure were simultaneously recorded to assess patient-ventilator synchrony. Results: NIV-NAVA was feasible and well tolerated in all patients. One patient asked to stop the study early because of anxiety related to the leak-free facial mask. Inspiratory trigger dys-synchrony and cycling-off dys-synchrony were significantly shorter in NIV-NAVA versus initial and final conventional NIV periods (both p< 0.05). Wasted efforts were also decreased in NIV-NAVA (all values expressed as median and interquartile values): 0 (0 - 0) in NIV-NAVA versus 12% (4 - 20) and 6% (2 - 22) in initial and final conventional NIV, respectively (p< 0.01). As a whole, total time spent in asynchrony was reduced to 8% (6 - 10) in NIV-NAVA, versus 27% (19 - 56) and 32% (21 - 38) in initial and final conventional NIV, respectively (p= 0.05). No difference in term of respiratory effort was noted. Conclusion: NIV-NAVA is feasible and well tolerated in PICU patients and allows improved patient-ventilator synchronization. Larger controlled studies are warranted to evaluate the clinical impact of these findings.
207

La protéine IQGAP1 dans le podocyte : caractérisation et implications physiopathologiques / IQGAP1 protein in the podocyte : characterization and pathophysiology involvements

Rigothier, Claire 26 November 2012 (has links)
Le syndrome néphrotique idiopathique (SNI) se caractérise par un remodelage du cytosquelette des podocytes et par une réorganisation des complexes protéiques podocytaires dont le diaphragme de fente. Récemment, une protéine fondamentale dans le remodelage du cytosquelette a été identifiée au niveau des pédicelles : IQGAP1. Nous sommes partis de l’hypothèse selon laquelle IQGAP1 par ses propriétés et ses caractéristiques biologiques connues dans différents modèles cellulaires (protéine d’échafaudage, remodelage du cytosquelette, migration cellulaire) pourrait être fondamentale dans les modifications ultrastructurales observées au cours du SNI. Au cours de ce travail de thèse, nous avons analysé les caractéristiques de la protéine IQGAP1 dans les podocytes humains, son implication dans les fonctions podocytaires et dans la physiopathologie du SNI. Nous avons dans un premier temps caractérisé les propriétés de la protéine IQGAP1 au sein des podocytes et déterminé sa localisation cellulaire à l’interface entre le cytosquelette et les complexes protéiques apical et diaphragmatique. Nous avons démontré le rôle d’IQGAP1 dans la migration podocytaire et dans la perméabilité de la monocouche épithéliale. Ces phénomènes au cours du SNI étant modifiés, nous avons dans un second temps étudié l’implication d’IQGAP1 dans la physiopathologie du SNI à l’aide de différents modèles expérimentaux (aminonucléoside de puromycine, plasmas de patients présentant un SNI, podocytes mutés pour la PLCε1). Nous avons ainsi démontré la translocation nucléaire de la protéine IQGAP1, dépendante de la voie ERK et de la PLCε1 et son implication dans la survie cellulaire par son interaction avec la chromatine. Au cours du SNI expérimental, nous avons observé une modification des propriétés d’IQGAP1 : localisation, interactions, phosphorylation.Cette approche a permis de démontrer l’implication de la protéine IQGAP1 dans le SNI. Compte tenu de son rôle dans le remodelage du cytosquelette, IQGAP1 pourrait également être un facteur dans la genèse de différentes glomérulopathies. / Idiopathic nephrotic syndrome (INS) is characterized by the pedicel cytoskeleton remodelling and the disruption of the slit diaphragm complex. Recently, a pivotal protein involved in cytoskeleton remodelling has been identified in podocytes: IQGAP1.We hypothesized that IQGAP1 may be crucial in ultrastructure changes observed in INS through its biological properties and characteristics reported in different cell types (scaffold protein, cytoskeleton dynamism, cell migration). Thus, we analysed IQGAP1 characteristics in human podocytes, its involvement in podocyte functions and in the INS pathophysiology. We have characterized IQGAP1 podocyte characteristics and clarified its cell localisation between the cytoskeleton and the apical or diaphragmatic protein complexes Our work demonstrated the role of IQGAP1 in podocyte motility and in the permeability of epithelial monolayer. With respect to the modification of these phenomenons during INS, we have studied IQGAP1 involvement in INS pathophysiology with different experimental models (puromycine aminonucleoside, plasmas from patients suffering from INS, PLCε1 mutated podocytes). We have demonstrated IQGAP1 nuclear translocation, dependant to ERK signaling pathway and to PLCε1 and its involvement in cell survival through its interaction with the chromatin. In the experimental INS, we have observed a modification of IQGAP1 properties: localization, interactions, phosphorylation. This approach allowed us to show IQGAP1 involvement in INS. Through its role in cytoskeleton remodelling, IQGAP1 may be a factor in the development of different glomerulopathies.
208

Comparação da assincronia toracoabdominal ao repouso e ao exercício em pacientes com doença pulmonar obstrutiva crônica utilizando diferentes metodologias / Comparison of thoracoabdominal asynchrony at rest and during exercise in chronic obstructive pulmonary disease patients by applying different methodologies

Porras, Desiderio Cano 23 July 2014 (has links)
Pacientes portadores de doença pulmonar obstrutiva crônica (DPOC) podem apresentar assincronia toracoabdominal (ATA). Existem diversos métodos de estimativa da ATA, porém, não há um consenso sobre qual é o mais adequado. O objetivo deste estudo foi comparar dois métodos de estimativa da assincronia toracoabdominal e avaliar a ineficiência ventilatória em pacientes DPOC no repouso e durante o exercício. Foram avaliados 22 pacientes com DPOC (VEF1 40,2±10,5% predito) e 13 indivíduos controle (GC) pareados por idade, gênero e índice de massa corpórea. A cinemática toracoabdominal foi avaliada utilizando pletismografia optoeletrônica no repouso e durante o exercício leve e moderado (70% da carga máxima) no ciclo ergômetro. A ATA foi calculada entre a caixa torácica superior (CTS) e inferior (CTI) e o abdome (ABD) utilizando os métodos de ângulo de fase (AF) e relação de fase (RF). A ineficiência ventilatória foi calculada em cada compartimento como a diferença entre o volume máximo (VM) e o volume calculado (VC) de acordo com o ciclo respiratório (determinado pela soma de volume dos três compartimentos) dividida pelo volume máximo (VM-VC)/VM. Os pacientes com DPOC foram classificados como assíncronos (grupo AT) ou não assíncronos (grupo NA) utilizando como referência os valores do GC. Foi utilizado o teste qui-quadrado ou de Fisher para avaliar a discriminação de pacientes entre os métodos e o ANOVA de dois fatores para comparações entre os grupos. O nível de significância foi ajustado para 5%. O método AF determinou maior número de pacientes com ATA quando comparado com RF no repouso (respectivamente, 15 vs. 7) e no exercício leve (11 vs. 3) e moderado (14 vs. 8). Os valores de assincronia no grupo AT entre CTS-CTI e CTI-ABD foram maiores no repouso (AF: 35,7±45,4° e -42,2±42,5° e RF: 61,8±29,1° e -66,9±27,4°, respectivamente) e no exercício leve (AF: 53,3±35,6° e -55,8±40,4°; RF: 106,1±40,3° e - 124,8±17,2°) e moderado (AF: 61,6±55,1° e -75,9±44,8°; RF: 85,9±23,6° e -81,8±42,2°) quando comparados com os grupos NA (p < 0,05) e GC (p < 0,05). Na análise entre CTSABD não houve diferença entre os grupos. Observou-se que o grupo AT apresentou menor contribuição e maior ineficiência ventilatória da CTI em todos os momentos de avaliação e, durante o exercício moderado, menor volume corrente quando comparado com os grupos NA e GC. Os nossos resultados sugerem que o ângulo de fase apresenta maior detecção de ATA nos pacientes com DPOC. A presença de assincronia parece ocorrer principalmente na caixa torácica inferior e associada com menor contribuição e maior ineficiência ventilatória deste compartimento / Chronic obstructive pulmonary disease (COPD) patients can present thoracoabdominal asynchrony (TAA). There are several TAA estimation techniques, however, there is no consensus about which is the most appropriate. The aim of this study was to compare two thoracoabdominal asynchrony quantification techniques and to assess chest wall ventilatory inefficiency in COPD patients at rest and during exercise. We evaluated 22 COPD patients (FEV1 40,2±10,5% predicted) and 13 healthy controls (CG) matched by age, gender and body mass index. Thoracoabdominal kinematics was assessed via optoelectronic plethysmography at rest and during mild and moderate exercise (70 % maximum workload) in a cycle ergometer. TAA was calculated among upper (URC) and lower ribcage (LRC) and abdomen (ABD) by using the phase angle (PA) and phase relation (PR) approaches. Ventilatory Inefficiency was estimated in each compartment as the difference between the maximal volume (VM) and the volume (VC) calculated according to respiratory timing (sum of volume in the 3 compartments) divided by the maximal volume (VM-VC)/VM. COPD patients were classified as asynchronous (AT group) or not (NA group) by using as reference the values on the controls. Chi-square or Fisher\'s exact test was used for assessing the patients differentiation between the two TAA quantification approaches and two-way ANOVA was used to compare respiratory parameters among groups (CG, AT and NA). Statistical significance was set at 5% level. PA approach determined more patients as asynchronous when compared to RF at rest (respectively, 15 vs. 7) and during mild (11 vs. 3) and moderate (14 vs. 8) exercise. Asynchrony values in AT group among URC-LRC and LRC-ABD were greater at rest (respectively, 35.7±45.4° and -42.2±42.5° with PA and 61.8±29.1° and -66.9±27.4° with PR) and during mild (PA: 53.3±35.6° and -55.8±40.4°; PR: 106.1±40.3° and -124.8±17.2°) and moderate exercise (PA: 61.6±55.1° and - 75.9±44.8°; PR: 85.9±23.6° and -81.8±42.2°) when compared to NA (p < 0.05) and CG (p < 0.05). Analysis among URC-ABD presented no difference between groups. It was observed that AT group presented a smaller LRC contribution and greater ventilatory inefficiency during all assessing moments and, during moderate exercise, had a lower tidal volume when compared to NA and CG. Our results suggest that phase angle approach presents larger TAA detection in COPD patients. This asynchrony seems to occur mainly in the lower ribcage and be associated with decreased contribution and increased ventilatory inefficiency of this compartment
209

Évaluation du travail respiratoire dans l’insuffisance respiratoire aiguë de l’enfant

Mortamet, Guillaume 01 1900 (has links)
No description available.
210

Modélisation physique de l’impact du creusement d’un tunnel par tunnelier à front pressurisé sur des fondations profondes / Study of the impact of tunneling with an EPB TBM on the surrounding buildings

Bel, Justin 28 March 2018 (has links)
Le travail de thèse présenté dans ce mémoire vise à analyser et à comprendre les mécanismes mis en jeu au niveau de l’impact du creusement d’un tunnel par bouclier à front pressurisé sur des fondations profondes avoisinantes. Cette thèse a été réalisée dans le cadre du projet européen NeTTUN, au sein du Laboratoire de Tribologie et de Dynamique des Systèmes (LTDS) de l’ENTPE. L’approche phénoménologique conduite lors de ces travaux repose sur deux importantes campagnes expérimentales réalisées à l’aide d’un dispositif unique au plan international de modèle réduit 1g de tunnelier à pression de terre (échelle de l’ordre de 1/10eme). La forte originalité de ce dispositif est de pouvoir simuler de façon réaliste les principales étapes du processus tridimensionnel d’excavation mécanisé d’un tunnel. Dans le cadre de cette thèse, le dispositif existant de modèle réduit de tunnelier a dans un premier temps été reconfiguré afin de pouvoir répondre aux besoins du programme expérimental envisagé. Des modèles physiques de fondations profondes (pieux et groupes de pieux) et de barrières de protection ont été conçus dans le cadre des lois de similitude, fabriqués et instrumentés. Deux campagnes expérimentales d’envergure ont été réalisées en massif de sable sec : l’une concerne les effets du passage d’un tunnelier à front pressurisé sur des fondations profondes avoisinantes (pieux, groupe de pieux), l’autre traite de l’efficacité de barrières de protection (parois moulées) utilisées pour limiter ces effets. Différents paramètres qui influencent l’interaction tunnelier - sol - fondations ont été considérés comme la distance relative tunnel / fondation, la pression frontale de soutènement appliquée par le TBM sur le terrain ou encore la hauteur des barrières de protection. L’analyse phénoménologique menée à l’échelle du modèle concerne en particulier l’évolution des champs de contraintes et de déplacements dans le terrain autour du tunnelier, les déplacements relatifs sol - pieu et sol- barrière, la redistribution des efforts au sein des fondations. L’importante base de données et d’analyse ainsi constituée a été mise à profit pour la validation d’outils de modélisation numérique développés par l’Université de Rome au sein du projet NeTTUN. / The major goal presented in this thesis was to analyze and investigate the mechanisms, which are involved in the impact of the tunnels excavated thanks to an Earth Pressure Balanced Shield on nearby deep foundations. This thesis was realized in European project NeTTUN and the work had been done in the Laboratory of Tribology and Systems Dynamics (LTDS) of ENTPE. During these works, phenomenological approach was based on two important experimental campaigns carried out using a unique device at the international level of a 1g scale model of earth-pressure tunnel boring machine (scale of the order of 1 / 10). The state of the art of this device was to be able to simulate in possibly realistic way the main stages of the three-dimensional process of mechanized excavation of a tunnel. In the framework of this thesis, the existing model tunneling machine device was initially reconfigured in order to reach the expectations of the experimental program envisaged. Physical models of deep foundations (piles and groups of piles) and protective barriers were designed under the similitude laws, manufactured and instrumented. The two large-scale experimental campaigns have been carried out in a dry sand massif. The first one concerned the effects of the passage of a pressurized tunnel boring machine on nearby deep foundations (piles, group of piles), whereas another one dealed with the effectiveness of mitigation procedure (diaphragm walls) used to limit these effects. Different parameters that influenced on the tunneling: soil - foundation interaction considered as the relative tunnel / foundation distance, the frontal face pressure applied by the TBM in the field or the height of the protective barriers. The phenomenological analysis carried out at the scale of the model concerned in particular the evolution of the fields of stresses and displacements in the ground around the tunnel boring machine, relatives pile / soil and wall / soil displacements and the redistribution of stresses along the pile foundations. The large database and analysis constituted was used for the validation of numerical modeling tools developed by the University of Rome within the NeTTUN project.

Page generated in 0.0488 seconds