• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 62
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 62
  • 43
  • 35
  • 34
  • 28
  • 28
  • 12
  • 12
  • 11
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Valores de referência e confiabilidade de testes clínicos para avaliação funcional lombopélvica / Reference values and reliability for tests of lumbopelvic functional assessment

Oliveira, Isadora Orlando de 16 September 2016 (has links)
Introdução: Força, resistência e atividade muscular são uma área importante de pesquisa e avaliação contribuindo para um melhor entendimento de aspectos musculoesqueléticos de mecanismos de dor e lesão. No entanto, a utilização de testes que avaliem a região lombopélvica ainda é controversa, pois apesar de muitos testes clínicos estarem disponíveis na literatura, ainda não estão estabelecidos quais os mais confiáveis na prática clínica. Objetivos: Estabelecer valores de referência, determinar confiabilidade intra e interexaminador e as medidas de erro de um conjunto de testes clínicos que avaliam a região lombopélvica em indivíduos assintomáticos de diferentes gêneros, faixas etárias e níveis de atividade física. Materiais e Métodos: Para os valores de referência, 152 indivíduos (79 homens, 73 mulheres) estratificados por gênero, faixa etária e nível de atividade física realizaram um conjunto de nove testes clínicos: força isométrica máxima de abdutores, extensores, flexores e rotadores laterais de quadril, resistência nas posições de ponte lateral, ponte frontal, flexores e extensores lombares e atividade muscular da região lombopélvica. Para a confiabilidade, 33 indivíduos foram avaliados por dois examinadores em um intervalo de 3 a 7 dias, onde realizaram aleatoriamente o mesmo conjunto de testes. As medidas de confiabilidade foram avaliadas pelo Coeficiente de Correlação Interclasse (CCI2,1) e as medidas de erro definidas pelo Erro Padrão da Medida (EPM) e pela Mínima Mudança Detectável (MMD). Resultados: Foram observadas diferenças significativas (p<0.05) nos testes clínicos para as variáveis: gênero, faixa etária e nível de atividade física e estabelecidos valores de referência para cada grupo. Todos os testes apresentaram valores de confiabilidade excelente com CCI (IC 95%) maior que 0.8 para as confiabilidades intra e interexaminador; os valores da MMD foram superiores à média do EPM em todos os testes. Conclusão: Os resultados do presente estudo apontam valores de referência que contribuem com o estabelecimento de referências para auxiliar na tomada de decisões clínicas. Além disso, este conjunto de 10 testes apresentou confiabilidade intra e interexaminador bem como valores de EPM e MMD, confirmando a possibilidade de seu uso na prática clínica. / Background: The assessment of the lumbopelvic region is useful for many musculoskeletal dysfunctions. Several clinical tests are commonly used to assess this region, however, reference values for clinical assessments and results concerning method, reliability and error measurements of these tests have not been reported. Objectives: To establish reference values and to determine intra and interrater reliability, standard error of measurement (SEM) and minimum detectable change (MDC) of a set of clinical tests used for assessing the lumbopelvic region in asymptomatic volunteers of different gender, age groups and physical activity levels. Methods: For reference values, 152 subjects (79 men, 73 women) divided by gender, age group and physical activity levels, performed nine clinical tests: Maximum voluntary isometric strength of hip abductors, extensors, flexors and lateral rotators, transversus abdominis(TrA) muscle activity (using a Pressure Biofeedback Unit), prone and side bridges, trunk flexor and extensor endurance tests. To measure reliability, 33 individuals performed the same set of tests, in random order within a week period. Intrarater and interrater analysis were assessed using the Intraclass Correlation Coefficient (ICC) and the error measurements were defined by using the SEM and the MDC. Results: Reference values were established for each group and our results showed significant (p<0.05) differences concerning gender, age group and physical activity levels in clinical tests. In general, strength differences were related to gender and physical activity levels and endurance results could be related to interactions between gender, age group and physical activity levels. All tests presented good reliability indices with an ICC (95%CI) higher than 0.8 for the intrarater and interrater reliability; MDC values were greater than mean of SEM in all tests, confirming its usage for clinical practice assessments. Conclusion: Reference values are necessary to help clinicians in the evaluation of subjects and these results can contribute for clinical practice in providing clinical training targets. Also, this set of tests presented good intra and interrater reliability measures of strength, endurance and TrA muscle activity test as well as SEM and MDC values, confirming its use for assessing the lumbopelvic region.
22

Desempenho e emissões de motor agrícola ciclo diesel utilizando diferentes combustíveis / Performance and emissions for agricultural cycle diesel engine using different fuel's

Perin, Gismael Francisco 25 July 2014 (has links)
The behavior of the agricultural cycle diesel engine when changes the fuel type and operating mode, must be known so that we can identify the best fuel resulting in better performance at lower emissions. However, when using particular type of fuel, with or without blends, the motor parameters such as torque, power and consumption, and emissions of gases changes. Therefore, the aim of this work was to verify the influence of the types of fuels for performance parameters of the agricultural cycle diesel engines and the emissions generated by burning fossil fuels. For this first experiment was conducted to determine the ideal number of repetitions and the warming s time the engine to perform the experiments proposed by objectives. Eighteen repeticions were conducted in 3 groups corresponding to warm times of 20, 60 and 100 minutes. To identify whether there was a significant difference between the warming s time was conducted the analysis of variance and the minimum number of repetitions required was identified by a lower rate of coefficient of variation. The experimental performance of the engine with different fuels was performed using 11 fuel (Diesel S10, S500 diesel, biodiesel and its blends [5%, 10%, 15%, 20%, 50% and 100% concentration of biodiesel in diesel]). Outcome variables were assessed torque, power consumption and time specific consumption. Analysis of variance was performed and, if present difference, the data were subjected to the mean comparison test (Tukey p ≥ 0.05) and linear regression analysis. Emissions of O2, CO2, NO2, NO, CO and HC were analyzed. The fuels used were the same performance experiment with the same blends. The emissions test followed the methodology laid down in the NBR ISO 8174-4:2012, which indicates 8 modes of operation of the engine in three rotations. Analysis of variance was performed and, if present difference, the data were subjected to the mean comparison test (Tukey p � 0.05) and linear regression analysis. The results report that four were the number of repetitions for the test performance and that 20 minutes was the time of warming the engine. Both the type of fuel and the operating mode significantly alter the performance and emissions. There was a reduction of the maximum torque and maximum power and increased consumption and minimum specific consumption with increase of biodiesel in the blend. Emissions of NO2 and O2 increased with higher concentration of biodiesel in the blend. Emissions of CO2, opacity, NO, CO and HC were decreased as increasing the amount of biodiesel in the blend with mineral diesel. In all variables, except O2, there was a reduction in emissions decreased when the load applied in engine. The fuel reduced emissions and maintained performance, compared with commercial diesel fuel was Diesel S10 with 20% biodiesel. / O comportamento dos motores agrícolas ciclo Diesel quando altera-se o tipo de combústivel e o modo de operação, deve ser conhecido para que se possa identificar qual o melhor combustível que resulte em melhor desempenho e menor emissão de poluentes. Entretanto, quando se utiliza determinado tipo de combustível, com ou sem misturas, os parâmetros do motor como torque, potência e consumo, e as emissões de gases se alteram de maneira diferenciada. Portanto, o objetivo deste trabalho foi verificar a influência dos tipos de combustíveis nos parâmetros de desempenho dos motores agrícolas ciclo Diesel e nas emissões de gases gerados pela queima destes combustíveis. Para isto, primeiramente foi realizado um experimento para determinar o número de repetições ideal e o tempo de aquecimento do motor para realizar os experimentos propostos pelos objetivos. Foram realizados 18 repetições separadas em 3 grupos, correspondentes aos tempos de aquecimento de 20, 60 e 100 minutos. Para identificar se houve diferença significativa entre os tempos de aquecimento foi realizado a análise da variância e o número de repetições mínimo necessário foi identificado pelo menor índice de coeficiente de variação. O experimento de desempenho do motor com diferentes combustíveis foi realizado utilizando 11 combustíveis, (Diesel S10, diesel S500, biodiesel e suas misturas [5%, 10%, 15%, 20%, 50% e 100% de concentração de biodiesel no diesel]). As variáveis respostas avaliadas foram torque, potência, consumo horário e consumo específico. Foi realizado a análise da variância e, caso apresentasse diferença, os dados foram submetidos ao teste de comparação de médias (Tukey p� 0,05) e análise de regressão linear. Ainda foram analisadas as emissões de O2, CO2, opacidade, NO2, NO, CO e HC. Os combustíveis utilizados foram os mesmos do experimento de desempenho, com as mesmas misturas. O ensaio de emissões seguiu a metodologia prevista na Norma NBR ISO 8174-4:2012, que indica 8 modos de operação do motor em três rotações. Foi realizado a análise da variância e, caso apresentasse diferença, os dados foram submetidos ao teste de comparação de médias (Tukey p≥ 0,05) e análise de regressão linear. Os resultados informam que quatro foram o número de repetições para o ensaio de desempenho do motor e que 20 minutos foi o tempo de aquecimento do motor. Tanto o tipo de combustível quanto o modo de operação alteraram significativamente o desempenho e as emissões. Houve redução do torque máximo e da potência máxima e aumento do consumo horário e específico mínimo com incremento de biodiesel na mistura. As emissões de NO2 e O2 aumentaram com a maior concentração de biodiesel na mistura. Já as emissões de CO2, opacidade, NO, CO e HC reduziram conforme foi aumentado o teor de biodiesel na mistura com diesel mineral. Em todas as variáveis analisadas, com exceção do O2, ocorreu redução das emissões quando se diminuiu a carga aplicada no motor. O combustível que reduziu as emissões e manteve o desempenho, comparativamente com o diesel comercial, foi o Diesel S10 com 20% de biodiesel.
23

Desenvolvimento de um sistema de controle de dinamômetro para testes de motores de combustão interna / Development of a dynamometer control system of tests for internal combustion engines

Haical, Rafael da Cruz January 2009 (has links)
Este trabalho aborda o desenvolvimento de um sistema de controle em malha fechada de torque e velocidade de rotação para testes de motores de combustão interna em uma bancada que possui um dinamômetro de correntes de Foucault. É apresentada uma revisão bibliográfica que abrange a fundamentação teórica básica sobre dinamômetro, alguns dos principais testes realizados em motores de combustão interna e técnicas de controle e instrumentação que estão sendo desenvolvidas por pesquisadores sobre o tema de controle de dinamômetro para testes de motores de combustão interna. O projeto surgiu com a necessidade do Laboratório de Motores da UFRGS realizar vários testes em motores a combustão tendo uma maior confiabilidade e rapidez para aquisição dos resultados. Este sistema está baseado num microcontrolador da família Atmega onde foram implementados os algoritmos de um controlador PID e um proporcional, que controlam respectivamente, os níveis de corrente contínua aplicadas no dinamômetro e o percentual de abertura da borboleta do motor combustão através de um motor de passo. A etapa de controle é executada no microcontrolador e uma interface gráfica foi implementada em Labview. Esta interface gráfica faz a leitura via porta serial dos dados do microcontrolador e traça suas curvas as salvando em arquivo, também se pode visualizar os sinais das temperaturas do motor e dinamômetro e nível de combustível do reservatório. A validação do controle desenvolvido foi comprovada através da verificação da convergência dos sinais para os valores de referência desejados. O controle propiciou também uma diminuição dos tempos para obtenção das respostas desejadas em comparação com o sistema anterior de controle manual. / This paper describes the development of a torque and rotation speed closed loop control system for internal combustion engine tests in a bench using a Foucault current dynamometer. A bibliographical review that encompasses basic dynamometer theoretical concepts, some of the most important tests applied to internal combustion engines, and control and instrumentation techniques currently under development on dynamometer testing for internal combustion engines is presented. This project needs to perform tests in combustion engines which would produce more dependable and faster results. The system herein developed is based on an Atmega-type microcontroller where algorithms of both a PID and a proportion controller, controlling respectively the levels of direct current applied through the dynamometer coils and the opening of an internal combustion engine throttle body by means of a step motor, were implemented. The control stage was done in the microcontroller and a graphic interface for a personal computer was created in Labview. This graphic interface facilitates the microcontroller data reading and traces its curves, saving them in a file; also, the engine and dynamometer temperature signals and the tank fuel level can be visualized. The validation of this control has been proved by the signal convergence check for desired reference values. Furthermore, the control has enabled a reduction in ideal answer time attainment as compared to the previous manual system.
24

Proposta de uma protocolo para avaliação da estabilidade vertebral a partir das propriedades passivas e ativas dos músculos extensores do tronco em individuos assintomáticos / Fernanda Maria Cercal Eduardo ; orientadora, Auristela Duarte de Lima Moser

Eduardo, Fernanda Maria Cercal January 2013 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2013 / Bibliografia: f. 100-112 / A atividades funcionais de um individuo e por isso o sistema de estabilização do corpo humano vem sendo amplamente estudado e várias teorias sendo descritas. Porém. de acordo com a literatura estudada, não existe ainda um método que avalie a estabilidade / joint stability is a prerequisite for the functional activities of an individual and therefore the stabilization system of the human body has been widely studied and several theories have being described. However, according to literature, there is still a
25

Função dos músculos abdutores e rotadores laterais do quadril no tratamento da síndrome da dor femoropatelar

Nakagawa, Theresa Helissa 29 February 2008 (has links)
Made available in DSpace on 2016-06-02T20:19:07Z (GMT). No. of bitstreams: 1 1779.pdf: 2726948 bytes, checksum: c8ab58197e37415b4dea31e8c0db1a77 (MD5) Previous issue date: 2008-02-29 / Financiadora de Estudos e Projetos / Contexto: A síndrome da dor femoropatelar (SDFP) é uma dos problemas mais comuns do joelho na população atlética. Recentemente, fatores proximais, incluindo a fraqueza e o pobre controle motor dos músculos do quadril, têm sido apontados como fatores contribuintes para o desenvolvimento da SDFP. Contudo, nenhum estudo avaliou a função excêntrica dos músculos do quadril em sujeitos com a SDFP. Objetivo: Comparar a função excêntrica dos músculos do quadril entre mulheres com a SDFP e mulheres sadias. Delineamento experimental: Estudo transversal. Ambiente: Laboratório de Musculoesquelética. Pacientes ou outros participantes: Foram estudados dois grupos: um grupo de mulheres com a SDFP (n=10) e um grupo de mulheres sem história de lesão ou cirurgia em membros inferiores (n=10). Metodologia: O pico de torque isocinético excêntrico de abdução, adução, rotação lateral e medial de quadril foi coletado e expresso como uma porcentagem da massa corporal (Nm/Kg x 100). Também foram avaliadas as razões dos torques de adução/abdução e rotação medial/rotação lateral do quadril. A atividade eletromiográfica do glúteo médio foi coletada durante a contração excêntrica de abdução do quadril e expressa como uma porcentagem da contração isométrica voluntária máxima. Resultados: Os indivíduos com a SDFP apresentaram diminuição significativa do pico de torque excêntrico de abdução (p= 0,008) e adução (p= 0,008) do quadril quando comparados aos indivíduos sadios. Não foi encontrada nenhuma diferença no pico de torque excêntrico de rotação lateral (p= 0,96) ou medial (p= 0,51) entre os grupos. A razão do torque de adução/ abdução do quadril foi significativamente maior no grupo com SDFP (p= 0,03), porém a razão do torque de rotação medial/ lateral não apresentou diferença ente os grupos SDFP e controle (p= 0,47). A atividade eletromiográfica do glúteo médio durante a avaliação da abdução excêntrica não apresentou diferença entre os grupos (p= 0,96). Conclusões: Mulheres com a SDFP demonstraram redução do pico de torque excêntrico de abdução e adução do quadril e aumento da razão do torque de adução/abdução do quadril quando comparadas às mulheres do grupo controle. Assim, os clínicos devem considerar os exercícios de fortalecimento excêntrico de abdução do quadril no desenvolvimento dos programas de reabilitação para mulheres com a SDFP.
26

Desenvolvimento de um sistema de controle de dinamômetro para testes de motores de combustão interna / Development of a dynamometer control system of tests for internal combustion engines

Haical, Rafael da Cruz January 2009 (has links)
Este trabalho aborda o desenvolvimento de um sistema de controle em malha fechada de torque e velocidade de rotação para testes de motores de combustão interna em uma bancada que possui um dinamômetro de correntes de Foucault. É apresentada uma revisão bibliográfica que abrange a fundamentação teórica básica sobre dinamômetro, alguns dos principais testes realizados em motores de combustão interna e técnicas de controle e instrumentação que estão sendo desenvolvidas por pesquisadores sobre o tema de controle de dinamômetro para testes de motores de combustão interna. O projeto surgiu com a necessidade do Laboratório de Motores da UFRGS realizar vários testes em motores a combustão tendo uma maior confiabilidade e rapidez para aquisição dos resultados. Este sistema está baseado num microcontrolador da família Atmega onde foram implementados os algoritmos de um controlador PID e um proporcional, que controlam respectivamente, os níveis de corrente contínua aplicadas no dinamômetro e o percentual de abertura da borboleta do motor combustão através de um motor de passo. A etapa de controle é executada no microcontrolador e uma interface gráfica foi implementada em Labview. Esta interface gráfica faz a leitura via porta serial dos dados do microcontrolador e traça suas curvas as salvando em arquivo, também se pode visualizar os sinais das temperaturas do motor e dinamômetro e nível de combustível do reservatório. A validação do controle desenvolvido foi comprovada através da verificação da convergência dos sinais para os valores de referência desejados. O controle propiciou também uma diminuição dos tempos para obtenção das respostas desejadas em comparação com o sistema anterior de controle manual. / This paper describes the development of a torque and rotation speed closed loop control system for internal combustion engine tests in a bench using a Foucault current dynamometer. A bibliographical review that encompasses basic dynamometer theoretical concepts, some of the most important tests applied to internal combustion engines, and control and instrumentation techniques currently under development on dynamometer testing for internal combustion engines is presented. This project needs to perform tests in combustion engines which would produce more dependable and faster results. The system herein developed is based on an Atmega-type microcontroller where algorithms of both a PID and a proportion controller, controlling respectively the levels of direct current applied through the dynamometer coils and the opening of an internal combustion engine throttle body by means of a step motor, were implemented. The control stage was done in the microcontroller and a graphic interface for a personal computer was created in Labview. This graphic interface facilitates the microcontroller data reading and traces its curves, saving them in a file; also, the engine and dynamometer temperature signals and the tank fuel level can be visualized. The validation of this control has been proved by the signal convergence check for desired reference values. Furthermore, the control has enabled a reduction in ideal answer time attainment as compared to the previous manual system.
27

Desenvolvimento de um sistema de controle de dinamômetro para testes de motores de combustão interna / Development of a dynamometer control system of tests for internal combustion engines

Haical, Rafael da Cruz January 2009 (has links)
Este trabalho aborda o desenvolvimento de um sistema de controle em malha fechada de torque e velocidade de rotação para testes de motores de combustão interna em uma bancada que possui um dinamômetro de correntes de Foucault. É apresentada uma revisão bibliográfica que abrange a fundamentação teórica básica sobre dinamômetro, alguns dos principais testes realizados em motores de combustão interna e técnicas de controle e instrumentação que estão sendo desenvolvidas por pesquisadores sobre o tema de controle de dinamômetro para testes de motores de combustão interna. O projeto surgiu com a necessidade do Laboratório de Motores da UFRGS realizar vários testes em motores a combustão tendo uma maior confiabilidade e rapidez para aquisição dos resultados. Este sistema está baseado num microcontrolador da família Atmega onde foram implementados os algoritmos de um controlador PID e um proporcional, que controlam respectivamente, os níveis de corrente contínua aplicadas no dinamômetro e o percentual de abertura da borboleta do motor combustão através de um motor de passo. A etapa de controle é executada no microcontrolador e uma interface gráfica foi implementada em Labview. Esta interface gráfica faz a leitura via porta serial dos dados do microcontrolador e traça suas curvas as salvando em arquivo, também se pode visualizar os sinais das temperaturas do motor e dinamômetro e nível de combustível do reservatório. A validação do controle desenvolvido foi comprovada através da verificação da convergência dos sinais para os valores de referência desejados. O controle propiciou também uma diminuição dos tempos para obtenção das respostas desejadas em comparação com o sistema anterior de controle manual. / This paper describes the development of a torque and rotation speed closed loop control system for internal combustion engine tests in a bench using a Foucault current dynamometer. A bibliographical review that encompasses basic dynamometer theoretical concepts, some of the most important tests applied to internal combustion engines, and control and instrumentation techniques currently under development on dynamometer testing for internal combustion engines is presented. This project needs to perform tests in combustion engines which would produce more dependable and faster results. The system herein developed is based on an Atmega-type microcontroller where algorithms of both a PID and a proportion controller, controlling respectively the levels of direct current applied through the dynamometer coils and the opening of an internal combustion engine throttle body by means of a step motor, were implemented. The control stage was done in the microcontroller and a graphic interface for a personal computer was created in Labview. This graphic interface facilitates the microcontroller data reading and traces its curves, saving them in a file; also, the engine and dynamometer temperature signals and the tank fuel level can be visualized. The validation of this control has been proved by the signal convergence check for desired reference values. Furthermore, the control has enabled a reduction in ideal answer time attainment as compared to the previous manual system.
28

Avaliação da força de preensão digital em trabalhadores de enfermagem / Assessment of digital grip strength in nursing professionals

Cheila Maíra Lelis 18 December 2014 (has links)
Objetivo: O presente estudo pretendeu avaliar a força de preensão digital em trabalhadores de enfermagem a fim de determinar as médias desta força e correlacionar com os fatores pessoais e ocupacionais Métodos: Estudo descritivo, correlacional, quantitativo, realizado em um hospital de ensino de Ribeirão Preto. Os sujeitos foram categorizados por meio de um questionário que abordou características pessoais e profissionais; para a mensuração da força de preensão digital foi utilizado um dinamômetro hidráulico Preston Pinch Gauge® (North Coast Medical - Estados Unidos), por meio deste foram realizadas três mensurações consecutivas para cada medida de força e utilizou-se a média destas pinças para as análises. As coletas de dados foram realizadas em 2013, este estudo recebeu a aprovação de Comitê de Ética e Pesquisa. Compuseram a amostra 41 profissionais de enfermagem do sexo feminino, que trabalhavam no período matutino. Foram realizados testes estatísticos e o nível de significância considerado foi ? = 0, 05; o programa utilizado nas análises foi a IBM SPSS (Statistical Package for Social Science) versão 22.0. Resultados: As trabalhadoras encontravam-se na faixa etária entre 21 e 60 anos; 56,1% eram casadas e 58,5% possuíam filhos; com relação ao nível de escolaridade 43,9% tinham ensino médio completo.No que diz respeito ao vínculo empregatício atual na enfermagem, 56,1% faziam seis horas semanais e 68,3% horas extras neste vinculo; 7,3% possuíam outro vínculo na área da enfermagem, porém sem realizar horas extras. Já se afastaram do trabalho por motivo de doença 63,4%; referiram sentir dor no dedo da mão 26,8%; 95,1% das trabalhadoras realizavam atividades domésticas em sua própria casa; 70,7% não praticavam atividade física; 58,5% possuíam algum tipo de atividade de lazer, foram observadas ainda doenças osteomusculares (27,3%). Os valores da médias gerais da pinças foram: 3,64 (kgf) polpa-a-polpa,3,85 (kgf), trípode; 6,08(kgf) lateral.Conclusão: Mesmo que não se tenha identificado uma porcentagem alta em relação a carga horária de trabalho associada as horas extras e o duplo vínculo, as variáveis independentes identificadas, influenciaram o desempenho dos testes de preensão de pinça, consequentemente, na diminuição bilateral das forças de preensão das pinças digitais estudadas. Entre as categorias profissionais e as médias de pinça houve correlação positiva e significativa, destacando pinças polpa-a-polpa (mão dominante). A força de preensão digital pode ser um indicador para determinar a função da mão e poder ser usada para indicar o grau de disfunção da extremidade superior acometida, não se pode afirmar que existam alterações relacionadas aos membros superiores das trabalhadoras de enfermagem, mesmo tendo em vista que a literatura infere que muitas das patologias associadas ao membro superior têm como alguns de seus sintomas iniciais a diminuição da força de pinças, fraqueza e dor nos dedos. Seria necessário agregar aos dados avaliados de preensão de digitais mais avaliações, como as clinicas, motoras e sensitivas. Diante do incipiente número de investigações relacionadas à força de preensão digital entre estas trabalhadoras, este estudo pretendeu contribuir na prevenção do desenvolvimento de disfunções ocupacionais, com a sugestão de inserção desta avaliação nos exames médicos admissionais, periódicos, de retorno ao trabalho e demissionais / Objective: This study aimed to evaluate the digital grip strength of nursing staff in order to determine the averages of this strength and correlate it to personal and occupational factors. Methods: Descriptive, co-relational, quantitative study carried out at a teaching hospital in Ribeirão Preto. Subjects were categorised by means of a questionnaire which addressed personal and professional characteristics; for the measurement of digital grip strength the hydraulic dynamometer Preston Pinch Gauge® (North Coast Medical - the United States) was used, with which three consecutive readings were made for each strength measurement and the mean of the pinches was used for the analysis. Data collection was performed in 2013 and this study was approved by the Research and Ethics Committee. 41 female nursing staff members composed the samples, all of whom worked in the morning. Statistical tests were made and the significance level considered was ? = 0.05; the program used for the analysis was IBM SPSS (Statistical Package for Social Science) version 22.0. Results: The workers were aged between 21 and 60 years; 56.1% were married and 58.5% had children; regarding the level of education 43.9% were high- school graduates. Concerning the current nursing employment relationship 56.1% worked six hours per week and 68.3% overtime in such relationship; 7.3% had other nursing labour bonds although not working overtime. 63.4% were away from work due to health complications; 26.8% indicated to suffer from finger pain; 95.1% of the workers performed household chores in their own houses; 70.7% did not do any physical activity; 58.5% had some kind of leisure activity, and osteomuscular conditions were still observed (27.3%). General mean values found were: 3.64 (kgf) pulp to pulp, 3.85 (kgf) three points and 6.08 (kgf) lateral pinch. Conclusion: Although there was not an identification of a higher percentage related to the working hours associated to overtime and double labour bond, the independent variables identified affected the pinch grip test performance, consequently reducing bilaterally the digital pinch grip strengths analysed. There was positive and significant correlation between the professional categories and the pinch means, highlighting pulp to pulp pinch(dominant hand). Digital grip strength can be an indicator to determine hand function and can be used to demonstrate the level of dysfunction of the affected upper limb ends, but it cannot be stated that there are alterations related to the upper limbs of nursing staff, even considering that the literature infers that many pathologies associated to the upper limbs present the reduction of pinch strength and finger weakness and pain as some of their initial symptoms. It would be necessary to add more evaluations to the already analysed data on digital grip, such as clinical, motor and sensitive evaluations. Before the incipient number of investigations related to the digital grip force among these workers, this study intended to contribute to the prevention of the development of occupational dysfunctions, suggesting the further introduction of this evaluation to admission, periodic, return to work and discharge medical examinations
29

Correlação da classificação funcional de atletas de basquete em cadeira de rodas com análise isocinética dos flexores, extensores e limites de estabilidade do tronco / Correlation of Wheelchair basketball functional classification system with Isokinetic analysis of trunk muscle strength and limits of stability

Sileno da Silva Santos 26 November 2013 (has links)
INTRODUÇÃO. A força muscular e o equilíbrio do tronco são os aspectos mais importantes para a determinação da classificação funcional de atletas de basquetebol em cadeira de rodas. O objetivo deste estudo foi analisar e correlacionar a força muscular e os limites de estabilidade do tronco de acordo com a classificação funcional para atletas de basquetebol em cadeira de rodas. MÉTODOS. Quarenta e dois atletas, com classificação funcional homologada pela federação paulista da modalidade, distribuídos nas quatro classes do Basquetebol em Cadeira de Rodas (Classe 1 n= 11; Classe 2 n=11; Classe 3 n= 9; Classe 4 n=11) com média de idade de 28,3±7.4 (16-46) anos, do sexo masculino tiveram a força muscular e equilíbrio de tronco avaliados. A força do tronco foi avaliada nos músculos extensores e flexores utilizando o dinamômetro isocinético Biodex® de forma isométrica com 15 º de amplitude. Os atletas realizaram uma série de 10 repetições com 15 segundos de descanso entre cada repetição. O equilíbrio do tronco foi avaliado no equipamento Balance Master® e o teste utilizado foi o de Limites de Estabilidade (LOS) de forma adaptada. Os atletas, sentados em um banco, realizaram movimentos voluntários do tronco em oito direções no plano frontal e lateral. Os movimentos foram feitos no sentido horário, ao redor de um perímetro, visualizado pelo paciente em um monitor e que representa o limite de 100% de deslocamento dado pelo equipamento. RESULTADOS. Considerando a distribuição dos atletas nas classes, houve diferença significativa na comparação dos índices de força muscular e equilíbrio entre as classes 1x3; 1x4 e 2x4. Houve correlação negativa (moderada) entre a força muscular do tronco em flexão e o DM (r=-.68, p=.02. Houve correlação positiva (forte) na classe 3 da força muscular do tronco em extensão e o DM (r=.92 p=0,001). CONCLUSÃO. A força muscular isométrica de flexão e extensão do tronco e os índices de equilíbrios de VD e DM nas direções anterior, posterior aumentam progressivamente com as classes e apresentam maiores diferenças na comparação entre as classes 1 e 3 e 1 e 4 e 2 e 4. Não houve correlação entre a força muscular isométrica dos flexores e extensores do tronco e os limites de estabilidade de acordo com a classificação funcional do BCR / BACKGROUND. Trunk muscle strength and balance are very important in defining the class of wheelchair basketball (WCB) athletes. This study aims to correlate and analyze trunk muscle strength and balance among high-performance Brazilian WCB athletes with their functional classification. METHODS. Forty-two male athletes of mean age 28.3±7.4 years (16-46) were divided into four groups based on WCB classes as follow: class 1 n=11; class 2 n=11; class 3 n=9; and class 4 n=11. The athletes performed a set of 10 repetitions of trunk flexion and extension with 15 seconds of rest between each repetition using the BiodexR isokinetic dynamometer in isometric form, with amplitude 15° to evaluate trunk muscle strength. In order to evaluate trunk balance, using the Balance Master® equipment and the Limits of Stability test (LOS), the athletes made voluntary trunk movements in eight directions (clockwise) in the frontal and lateral planes while seated on a bench. During the test, the athletes could view the movements on a monitor that represented the 100% displacement limit given by the equipment. RESULTS. There were significant differences in comparisons of trunk muscle strength and LOS in the classes 1vs.3, 1vs.4 and 2 vs.4. There was moderate negative correlation between trunk muscle strength in flexion and maximum excursion (r=-0.68; p=0.02). There was a strong positive correlation in class 3 between trunk muscle strength in extension and maximum excursion (r=0.92;p= 0.001). CONCLUSION. There was no correlation of isometric trunk muscle strength in flexion and extension and LOS indices, according to the functional classification of the WCB athletes
30

Estimativa do desempenho de tratores agrícolas em campo e pista a partir do ensaio dinamométrico / Estimate of the performance of agricultural tractors in field and track from dynamometric tests

Russini, Alexandre 22 March 2012 (has links)
The agricultural tractor allows to move and to pull machines and implements used during the execution of the activities to field. One of the largest problem refers to the acting of the tractor, the reason of a lot of questions between farmers and manufacturing companies. The perfomance determination is a much complex task, mainly when realized in field level, because the variables that should be analyzed are countless, inside of an extremely wide context. The solution found by a lot of researchers was the standardization through testings realized in concrete track, what shows unreliable results about the perfomance of the tractor in the field, besides they can be expensives. The aim of this work was to previse, through dynamometrics tests, the perfomance of an agricultural tractor of wheels in track and in the field, without appeal to the direct tests. The experiment was conducted in Federal University of Santa Maria, submitting a instrumented tractor to dynamic tests of traction in a paved surface and in the field, besides static tests, using an electric dynamometer with Foucault current. Through the use of equations, already conceptualized, was possible to create a interrelation between the following variables: torque and power of the engine, resistance to the rollover, wheel slipping, relation between the transmission relation and the tires dimensions, providing a way to estimate the power developed in the traction bar and the fuel consumption, with subsequent comparison with the dynamic tests. It was found by the correlation analysis, using obtained and estimated values, that there was a high correlation coefficient between the power traction observed in the track and in the field, relative to the estimated power (0.99 and 0.98) respectively.The equations estimating the fuel consumption presented a high adjustment for 90%, obtaining variation between the field treatments and the track in order to 1,19% and 2,09% respectively. Therefore, the estimate of the tractor performance can be made with high accuracy, just doing the dynamometric tests in laboratory, substituting the dynamic tests of field and track. / O trator agrícola permite movimentar e tracionar máquinas e implementos utilizados durante a realização das atividades a campo. Um dos maiores problemas refere-se ao desempenho do trator, razão de muitos questionamentos entre agricultores e empresas fabricantes. A determinação do desempenho é uma tarefa bastante complexa, principalmente quando realizada em nível de campo, pois inúmeras são as variáveis que devem ser analisadas, dentro de um contexto extremamente amplo. A solução encontrada por inúmeros pesquisadores foi a padronização através de ensaios realizados em pista de concreto, o que remete a resultados pouco precisos referindo-se ao comportamento do trator a campo, além de serem dispendiosos. O objetivo deste trabalho foi prever através de ensaios dinamométricos, o desempenho de um trator agrícola de rodas em pista e a campo, sem recorrer aos ensaios diretos. O experimento foi conduzido na Universidade Federal de Santa Maria, submetendo um trator instrumentado a ensaios dinâmicos de tração em superfície pavimentada e campo, além de ensaios estáticos, utilizando um dinamômetro elétrico de corrente de Foucault. Através do uso de equações, já conceituadas, pôde-se realizar a inter-relação das seguintes variáveis: torque e potência do motor, resistência ao rolamento, patinamento, relação de transmissão e dimensões dos pneus, obtendo-se uma estimativa da potência desenvolvida na barra de tração e consumo de combustível, com posterior comparação aos ensaios dinâmicos. Verificou-se através da análise de correlação, utilizando os valores obtidos e estimados, que houve um elevado coeficiente de correlação entre a potência de tração observada no campo e pista em relação à potência estimada, (0,99 e 0,98) respectivamente. As equações de estimativa do consumo de combustível apresentaram um ajuste superior a 90%, obtendo variação entre os tratamentos de campo e pista na ordem de 1,19% e 2,09% respectivamente. Portanto, a estimativa do desempenho de um trator pode ser feita com elevada exatidão, realizando-se o ensaio dinamométrico em laboratório, substituindo desta forma, os ensaios dinâmicos de campo e pista.

Page generated in 0.4323 seconds