• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 62
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 62
  • 43
  • 35
  • 34
  • 28
  • 28
  • 12
  • 12
  • 11
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo da musculatura flexora de dedos a partir da análise das curvas força-tempo / Study of the flexor muscles of fingers from the analysis of the force-time curves

Gorla, Júlia Andreza 01 November 2018 (has links)
Introdução - A análise da força de preensão manual durante a força realizada ao longo do tempo fornece dados referentes ao funcionamento biomecânico dos grupos musculares, com destaque à influência da musculatura flexora profunda e superficial dos dedos, bem como traz informações pertinentes ao desempenho funcional para atividades cotidianas. Objetivos - Analisar as curvas força-tempo da preensão palmar sob os aspectos de seus parâmetros discretos e de sua característica temporal. Identificar a influência da musculatura flexora profunda de dedos na preensão palmar. Método - Os voluntários realizaram o teste de esforço isométrico máximo utilizando o dinamômetro Jamar® e o transdutor de força computadorizado com duas empunhaduras, uma que permitia a ação do músculo flexor superficial de dedos e outra que a bloqueava. Foram analisadas as curvas força-tempo geradas de 9 indivíduos tanto em seus parâmetros discretos como em suas características temporais. Resultados - A força máxima média obtida com o Jamar® na Posição 1, sem distinção entre os sexos, (30,76 Kgf) aproximou-se dos valores da média nacional para mulheres (30,4 Kgf). Tanto no teste com o Jamar® como com o transdutor de força, os valores discretos foram maiores na Posição 1 (Fmáx Jamar®: 30,76/25,14 kgf; Fmáx transdutor: 22,16/17,37 kgf; Tmáx: 1,41/1,54 seg; Finf: 7,06/5,80 kgf). A fase de manutenção da força, equivalente a força de resistência, teve menor decréscimo nos testes realizados na Posição 2 (-1,02/-0,61). Além disso, os valores obtidos entre os dinamômetros mostram que o Jamar® superestima os valores de força máxima. Conclusões - Os dados apontam que há diferença na capacidade de manutenção da força, para a qual a ação do músculo flexor profundo dos dedos mostrou-se mais eficaz do que quando em conjunto com o flexor superficial dos dedos, tendo assim, grande importância funcional para a execução das atividades de vida diária. Evidencia-se que a análise da força por meio de suas características temporais fornece maior elucidação do desempenho muscular durante a força de preensão do que testes dinamométricos pontuais. / Introduction - The analysis of the manual grip force along time presents the biomechanical movement of muscle groups data, with emphasis on the deep and superficial flexor musculature of the fingers, as well as provides relevant information for the functional performance of daily activities. Objectives - To analyze the force-time curves of the palmar grip under the aspects of its discrete parameters and its temporal characteristic. Either, to identify the the influence of the flexor muscles of fingers in the palmar grip. Method - The volunteers performed the maximum isometric effort test using the Jamar® dynamometer and the computerized force transducer with two grips, one that allowed the action of the flexor superficial finger muscle, and another that blocks it. The force-time curves generated from 9 individuals were analyzed in both their discrete parameters and their temporal characteristics. Results - The medium of maximum strength obtained with Jamar® at Position 1, without distinction between gender, (30.76 Kgf) approached the national average for women (30.4 Kgf). In both the Jamar® and the force transducer tests, the discrete values were higher in Position 1 (Fmax Jamar®: 30.76 / 25.14 kgf; Fmax transducer: 22.16 / 17.37 kgf; Tmax: 1.41 / 1.54 sec; Finf: 7.06 / 5.80 kgf). The strength maintenance phase, equivalent to the resistive force, had a smaller decrease in the tests performed in Position 2 (-1.02 / -0.61). In addition, the values obtained between the dynamometers show that the Jamar® overestimates the maximum force values. Conclusions - The data points that there is a difference between the action of the flexor profound muscle group of the fingers and the flexor superficial one in the capacity of maintaining the force, showing that the profound group is more effective than combined with the superficial flexor, thus, the first one has great functional importance for performing activities of daily life. It evidences that the analysis of force on its temporary characteristics is more elucidative of the muscular performance during the grip force than the punctual dynamometric tests.
32

O treinamento por meio de realidade virtual melhora a funcionalidade dos músculos do assoalho pélvico de mulheres na pós-menopausa? Estudo controlado randomizado

MARTINHO, Natalia Miguel 12 March 2014 (has links)
Introdução e objetivos: O treinamento dos músculos do assoalho pélvico (TMAP) tem sido valorizado como meio de prevenir e tratar as disfunções uroginecológicas. Neste contexto, a realidade virtual parece ser uma ferramenta interessante na prevenção e tratamento de tais disfunções, por sua capacidade de simular atividades realizadas no mundo real, promovendo treinamento muscular de forma global e lúdica, que pode ser adequada de acordo com a condição desejada. Diante do exposto, o objetivo deste estudo foi investigar o efeito do TMAP por meio da realidade virtual sobre a funcionalidade dos músculos do assoalho pélvico (MAP), quando comparado a um protocolo de TMAP por meio de cinesioterapia. Material e Métodos: Participaram do estudo 47 mulheres com idade a partir de 50 anos e em fase de pós-menopausa, divididas de forma randomizada em dois grupos: (G1) TMAP por meio de cinesioterapia (n=20) e (G2) TMAP por meio de realidade virtual (n=27). As participantes foram avaliadas antes e cinco semanas após a realização dos protocolos, quanto à funcionalidade dos MAP: força muscular do assoalho pélvico (por meio de palpação digital e dinamometria vaginal), presença de prolapsos dos órgãos pélvicos (por meio do Pelvic Organ Prolapse Quantification), sintomas miccionais, sexuais e qualidade de vida (por meio de instrumentos validados). Resultados: Verificou-se melhora significativa (p<0,05) da força muscular, com concomitante melhora dos prolapsos de parede anterior e dos sintomas miccionais, em ambos os grupos. A qualidade de vida apresentou melhora significativa na maioria dos domínios em ambos os grupos; enquanto que a função sexual demonstrou melhora no escore total e no domínio lubrificação apenas no grupo de TMAP por meio de cinesioterapia. Conclusão: O TMAP por meio da realidade virtual se equipara ao TMAP por meio de cinesioterapia quanto à melhora da força dos músculos do assoalho pélvico, dos sintomas miccionais, dos prolapsos de parede anterior e da maioria dos domínios de qualidade de vida, demonstrando ser efetivo para mulheres na pós menopausa. / Introduction and aims: The pelvic floor muscle training (PFMT) has been highly valued as means to prevent and treat urogynecological dysfunction. At this context, virtual reality seems to be an interesting tool in prevent and treat such disorders, by its ability to simulate real-world activities, promote globally muscle training and playful activities, which can be tailored to the desired condition. Given the above, the aim of this study was to investigate the effect of PFMT through virtual reality on the functionality of the pelvic floor muscles (PFM), when compared to a PFMT through kinesiotherapy protocol. Materials and Methods: The study included 47 women aged over 50 years and in post-menopausal period divided randomly into two groups: (G1) PFMT through kinesiotherapy (n=20) and (G2) PFMT through virtual reality (n=27). Participants were assessed before and five weeks after to the implementation of protocols as the functionality of PFM: PFM strength (by digital palpation and vaginal dynamometry), presence of pelvic organ prolapse (using Pelvic Organ Prolapse Quantification), voiding and sexual symptoms and quality of life (by validated instruments). Results: There was significant improvement (p<0,05) in muscle strength, with concomitant improvement in anterior wall prolapse and urinary symptoms in both groups. Quality of life improved significantly in most areas in both groups; whereas sexual function, improved in total score and in the lubrication, only at PFMT through kinesiotherapy group. Conclusion: PFMT through virtual reality equates to PFMT through kinesiotherapy regarding the improvement of pelvic floor muscle strength, voiding symptoms, anterior wall prolapse and quality of life; proving to be effective for postmenopausal women. / Programa Institucional de Bolsas de Pós-Graduação - PIB-PÓS
33

Força de preensão manual e força máxima de mordida em indivíduos dentados e desdentados totais /

Jabr, Camila Luiz. January 2019 (has links)
Orientador: João Neudenir Arioli Filho / Resumo: A mensuração da força de mordida permite a avaliação da funcionalidade e da atividade do sistema estomatognático, sendo esta uma variável de grande importância para o cirurgião-dentista no estabelecimento do correto plano de tratamento e prognóstico das reabilitações orais. Os dinamômetros para medida de força manual são preditores de força global e apresentam acessibilidade técnica e financeira. O objetivo deste estudo foi estimar a correlação entre a força de preensão manual (FP) média e força máxima de mordida (FM) de indivíduos jovens dentados (G1), adultos dentados (G2) e desdentados totais usuários de próteses totais bimaxilares (G3) do sexo feminino. Após preencher o termo de consentimento livre e esclarecido, os participantes foram submetidos ao teste de mensuração da FP com o auxílio do dispositivo eletrônico digital na mão dominante e não dominante, um total de três mensurações para cada mão, para obtenção da média das mesmas. Posteriormente, através de um gnatodinamômetro digital, foi mensurada a FM na região de molar sendo considerada a média de três mensurações de cada lado. Foram calculados o Coeficiente de Correlação de Pearson (r) e Análise de Variância multivariada (MANOVA). Para comparação das médias, pós-teste de Tukey e de Games-Howell, a nível de significância de 5%. Observou-se uma correlação de moderada a forte entre as variáveis para todos os grupos: G1, G2 e G3 (r=0,838; 0,707; 0,643; respectivamente) e uma diferença significativa entre as médias de F... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The measurement of bite force allows the evaluation of the functionality and activity of the stomatognathic system, being a variable of great importance for the dentistry professionals in the establishment of the correct treatment plan for oral rehabilitations. Dynamometers for manual force measurement are predictors of global strength and have technical and financial accessibility. The aim of this study was to estimate the correlation between the average handgrip force (HF) and maximum bite force (BF) of young dentate (G1), dentate adults (G2) and female total edentulous users of bimaxillary total dentures (G3). After signed the consent form, the participants were submitted to the HF measurement test using the digital electronic device on both hands, three measurements for each hand, to obtain the average of the same ones. Subsequently, through a digital gnatodynamometer, BF was measured in the molar region and the average of three measurements on each side was considered. The Pearson Correlation Coefficient (r) and the Multivariate Analysis of Variance (MANOVA) were calculated. In order to compare the obtained average data, post-tests of Tukey and Games-Howell have been performed at a significance level of 5%. A moderate to strong correlation was observed among the variables for all groups: G1, G2 and G3 (r=0.838, 0.707, and 0.643, respectively) and a significant difference among the average BF data being G1>G2>G3 (p<0.05). Regarding the average of HF, G3 statistically diff... (Complete abstract click electronic access below) / Mestre
34

Desenvolvimento de um dinamômetro biomédico ergonômico com comunicação com dispositivos móveis /

Paulo, Danilo Pazian. January 2017 (has links)
Orientador: Aparecido Augusto de Carvalho / Resumo: Dinamômetros biomédicos são equipamentos utilizados para medir forças exercidas pelas mãos. Com o uso deste tipo de equipamento, é possível realizar avaliações biomecânicas das mãos de pacientes que após cirurgias, acidentes ou patologias osteomioarticulares, tiveram redução na sua capacidade de exercer forças com as mãos. O objetivo deste trabalho foi a implementação de um dinamômetro biomédico ergonômico, de fácil utilização, com capacidade de comunicação com diferentes tipos de dispositivos móveis, como smartphones e tablets. O projeto realizado se constitui no aprimoramento de duas versões anteriores de dinamômetros implementadas no Laboratório de Instrumentação Eletrônica e Engenharia Biomédica da UNESP –Campus de Ilha Solteira. Testes em voluntários utilizando o dinamômetro desenvolvido e um dinamômetro comercial da marca SAEHAN, e posterior análise estatística dos dados revelam uma excelente confiabilidade intra-examinador para o dinamômetro desenvolvido, com coeficiente de correlação intraclasse médio de 0,95 entre os diferentes grupos analisados, e de 0,98 para o dinamômetro SAEHAN. A análise estatística revela também uma excelente confiabilidade concorrente para as medidas realizadas pelo dinamômetro desenvolvido em relação às do dinamômetro SAEHAN, sendo de 0,93 para mãos dominantes e 0,92 para mãos não dominantes. Assim, o dinamômetro desenvolvido é confiável, válido e comparável com o dinamômetro SAEHAN quando adotados os mesmos procedimentos de exame de preensão... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Biomedical dynamometers are equipment used to measure forces exerted by the hands. Using this type of equipment, it is possible to perform biomechanical evaluations of the hands of patients that after surgery, accidents or diseases have had a reduction in the ability to exert force with their hands. The objective of this work was the implementation of an ergonomic biomedical dynamometer, easy to use, with ability to communicate with different types of mobile devices such as smartphones and tablets. The project carried out constitutes the improvement of two previous dynamometers versions implemented in the Electronic Instrumentation and Biomedical Engineering Laboratory at UNESP - Ilha Solteira. Volunteer tests using the developed dynamometer and a commercial SAEHAN dynamometer, and subsequent statistical analysis of the data revealed an excellent intra-examiner reliability for the developed dynamometer, a mean of 0,95 among different groups analyzed, and a mean of 0,98 for the SAEHAN dynamometer. The statistical analysis also revealed an excellent concurrent reliability for the measurements performed by the dynamometer developed in relation to those of the SAEHAN dynamometer, being 0,93 for dominant hands and 0,92 for non-dominant hands. Thus, the developed dynamometer is reliable, valid and comparable with the SAEHAN dynamometer when the same grip strength examination procedures were adopted. / Mestre
35

Efeitos do treinamento de estabilização funcional em mulheres saudáveis e com dor femoropatelar

Baldon, Rodrigo de Marche 25 April 2014 (has links)
Made available in DSpace on 2016-06-02T20:18:23Z (GMT). No. of bitstreams: 1 6052.pdf: 12537865 bytes, checksum: bf9fb0a86817f7ba88a928051b616139 (MD5) Previous issue date: 2014-04-25 / Financiadora de Estudos e Projetos / Hip and trunk strengthening exercises have been included in preventive programs and treatment protocols for patellofemoral pain (PFP). It is believed that the strengthening of these muscles might change the lower limb movement pattern during functional activities, reducing the patellofemoral stress. However, there is limited evidence about the clinical and biomechanical effects of the treatment focused on hip and trunk muscle strengthening and lower limb and trunk movement control, named functional stabilization training (FST). Thus, the objectives of this thesis were to verify the effects of the FST in healthy females, to compare the effects of the FST to the standard treatment (ST) in females with PFP, and to determine the muscle function mechanism(s) by which the FST leads to kinematic changes in the frontal plane. The 3D kinematics was assessed during the single-leg squat using a camera system and an electromagnetic tracking system. The hip and knee isokinetic torque was assessed with an isokinetic dynamometer and trunk muscle resistance was evaluated by way of sustained static postures. The functional performance was evaluated using the single-leg triple hop test, the timed 6-m single-leg hop test, and the Lower Extremity Functional Scale. The pain intensity was assessed with a 10cm visual analogue scale and the Global Rating of Change Scale was used to measure perceived improvement. The results of this thesis demonstrated that the healthy females and the patients with PFP performing the FST decreased the movement excursion of contralateral pelvis depression, hip adduction and knee abduction. Moreover, the patients performing the FST also decreased ipsilateral trunk inclination and increased pelvis anteversion and flexion. The FST was also effective in increasing hip and knee torque and functional performance in healthy females and in the patients with PFP as well as the trunk muscle endurance in PFP patients. The patients who performed the FST also showed less knee pain intensity and greater perceived improvement when compared to the patients who performed the ST. Finally, the strengthening of the gluteus muscles was associated with improvement of lower limb and trunk kinematics in the frontal plane. Therefore, the results of this thesis show that the FST causes significant lower limb biomechanical effects in healthy females and in patients with PFP. Moreover, the FST causes greater clinical improvements in patients with PFP when compared to the ST. / A inclusão de exercícios de fortalecimento dos músculos do quadril e tronco nos programa de prevenção e tratamento de pacientes com dor femoropatelar (DFP) tem sido recomendada. Acredita-se que o aumento da força desses músculos altere o padrão de movimento do membro inferior durante as atividades funcionais, reduzindo o estresse femoropatelar. Entretanto, há escassez de informações referentes aos efeitos clínicos e biomecânicos de um treinamento composto por esses exercícios associado com a utilização de recursos educacionais para a correção do alinhamento do membro inferior, denominado treinamento de estabilização funcional (TEF). Assim, os objetivos dessa tese foram: verificar os efeitos do TEF em mulheres saudáveis, comparar os efeitos do tratamento convencional com o TEF em mulheres com DFP e verificar as variáveis mediadoras das alterações cinemáticas do membro inferior e tronco no plano frontal resultantes da participação no TEF. A avaliação cinemática do membro inferior e tronco foi realizada durante o agachamento unipodal por meio da utilização de um sistema de câmeras e de rastreamento eletromagnético. O torque do quadril e joelho foi avaliado por um dinamômetro isocinético e a resistência dos músculos do tronco mensurada através da manutenção de posturas estáticas. O rendimento funcional foi verificado através dos testes de salto triplo unipodal, salto unipodal de 6 metros cronometrado e da aplicação do questionário Lower Extremity Functional Scale. A intensidade de dor no joelho foi verificada através de uma escala visual analógica e a percepção de melhora subjetiva das pacientes foi verificada pelo Global Rating of Chang Scale. Os resultados dessa tese demonstraram que o TEF reduziu a excursão de movimento de depressão contralateral da pelve, adução do quadril e abdução do joelho nas mulheres saudáveis e com DFP. Ainda, o TEF reduziu a inclinação ipsilateral do tronco e aumentou a anteversão da pelve e flexão do quadril em mulheres com DFP. O TEF também foi efetivo para aumentar o torque do quadril e joelho e a capacidade funcional das mulheres saudáveis e com DFP, assim como, a resistência dos músculos do tronco em pacientes com DFP. As pacientes que realizaram o TEF apresentaram menor intensidade de dor no joelho e maior percepção global de melhora clínica ao término da intervenção. Finalmente, foi observado que o aumento da força dos músculos glúteos foi associado com a melhora do alinhamento dinâmico do membro inferior e tronco no plano frontal. Assim, os resultados dessa tese demonstraram que o TEF é capaz de promover efeitos biomecânicos significativos no membro inferior de mulheres saudáveis e com DFP, além de gerar melhoras clínicas mais acentuadas em pacientes com DFP quando comparado ao tratamento convencional.
36

Análise da atividade elétrica e do torque da musculatura abdutora do ombro em sujeitos hemiparéticos crônicos

Avila, Mariana Arias 03 March 2010 (has links)
Made available in DSpace on 2016-06-02T20:19:13Z (GMT). No. of bitstreams: 1 2835.pdf: 1223404 bytes, checksum: 1a4c5a1d26182639b1c7ac48176b30fe (MD5) Previous issue date: 2010-03-03 / Financiadora de Estudos e Projetos / Background: There is still a lack of evidence of how electromyographic (EMG) patterns deficits of muscle activation are related to the shoulder abduction movement in people with chronic hemiparesis. Objective: Analyze EMG patterns and isokinetic muscle performance of shoulder abduction motion in subjects with chronic hemiparesis. Design: Cross-sectional trial. Methods: Twenty five subjects with chronic hemiparesis and twenty five healthy subjects underwent EMG activity and isokinetic shoulder abduction assessments. EMG onset time and RMS were compared between limbs (intra-group) and between groups (inter-group) for trapezius and deltoid muscles. Isokinetic peak torque, total work, average power and acceleration time were also compared intra- and inter-groups. Results: The paretic side showed an opposed onset activation pattern in shoulder abduction, along with a lower RMS for both muscles. The non-paretic side showed a delay in both muscles activation and a lower RMS for the trapezius, compared to the control group. Both sides of the group with hemiparesis presented a significantly lower isokinetic performance compared to the control group. Conclusions: Trapezius and middle deltoid muscles activation, as well as torque, speed and endurance are altered in both paretic and non-paretic shoulders in subjects with chronic hemiparesis. The non-paretic limb is less affected than the paretic one. These facts should be taken into account in the rehabilitation program after stroke. / Contextualização: Ainda há ausência de evidência na literatura de como déficits em padrões eletromiográficos (EMG) de ativação muscular estão relacionados ao movimento de abdução do ombro em sujeitos com hemiparesia crônica. Objetivo: Analisar os padrões EMG e o desempenho muscular isocinético do movimento de abdução do ombro em sujeitos hemiparéticos crônicos. Delineamento experimental: Ensaio transversal. Métodos: Vinte e cinco sujeitos hemiparéticos crônicos e vinte e cinco sujeitos saudáveis foram submetidos a uma avaliação da atividade EMG na abdução isocinética do ombro. O tempo de início da ativação muscular e a Root Mean Square (RMS) foram comparadas entre os membros (intragrupo) e entre grupos (inter-grupo) para os músculos trapézio e deltóide. O pico de torque, o trabalho total, a potência media e o tempo de aceleração, variáveis isocinéticas, também foram comparadas intra- e inter-grupos. Resultados: O lado parético mostrou uma inversão do padrão de ativação muscular e uma menor RMS para ambos os músculos comparado com o lado não-parético e o grupo controle. O lado não-parético mostrou um atraso no início da ativação tanto do deltóide quanto do trapézio, além de uma menor RMS para o trapézio, comparado com o grupo controle. Ambos os lados do grupo hemiparético mostraram um menor desempenho isocinético, comparados ao grupo controle. Conclusões: A ativação muscular do trapézio e do deltóide, bem como o torque, a velocidade e a resistência muscular estão alterados em ambos os ombros dos lados parético e não-parético no movimento de abdução do ombro. O lado não-parético é menos afetado do que o parético. Estes fatos devem ser levados em conta em um programa de reabilitação após um Acidente Vascular Encefálico.
37

Pacote de gelo e imersão em água gelada afetam o desempenho muscular e a atividade eletromiográfica

Vieira, Amilton 30 March 2012 (has links)
Made available in DSpace on 2016-06-02T19:22:55Z (GMT). No. of bitstreams: 1 4273.pdf: 640166 bytes, checksum: 0c9fc1f3e1c6ddb8472d73914461506a (MD5) Previous issue date: 2012-03-30 / Universidade Federal de Sao Carlos / Although tissue cooling is widely used in the treatment of musculoskeletal disorders there is still controversy about its effects on muscular performance. It is important to study this issue since cooling is also combined with exercise. Objective. To compare the effects of ice pack and cold water immersion on the muscular performance parameters of plantar flexors and electromyography (EMG) activity of the triceps surae. Design. Subjects were randomly assigned treatment with either ice pack (n=20) or cold water immersion (n=21). Independent variables were cold modality (ice pack or cold water immersion), muscle action (isometric and concentric isokinetic, angular velocity of isokinetic test (60 and 120°/s) and measurement time (pre- and post-cooling). Dependent variables were skin temperature, muscular performance and EMG activity. Methods. The sample included 41 healthy men with a mean age of 22.15 (SD=2.89). In each group one of the two cold modalities was applied to the calf region for 20 minutes. Skin temperature, plantar flexors muscular performance parameters and EMG activity of the triceps surae were measured before and after cooling. Results. Ice pack increased isometric peak torque. Both cold modalities reduced EMG activity in both muscles during isometric contraction. Both cold modalities reduced peak torque and total work during isokinetic contraction at both velocities. Ice pack was more effective at reducing EMG activity in isokinetic contractions. Limitations. The examiner was not blinded regarding treatment group and the population included only young healthy participants. Conclusions. Ice pack and cold water immersion showed similar effects on muscular performance, which depends on the muscle action performed. Cooling decreased isokinetic performance and the ice pack increased isometric torque. The results suggest that caution is required when performing activities after cooling, especially tasks involving maximal isokinetic contractions. / Embora o resfriamento tecidual seja amplamente utilizado no tratamento de lesões músculo esqueléticas há ainda controvérsias sobre seus efeitos no desempenho muscular. Estudar esse aspecto é importante uma vez que o resfriamento também é utilizado associado a exercícios físicos. Objetivo: Comparar os efeitos do pacote de gelo e da imersão em água gelada sobre parâmetros do desempenho muscular dos flexores plantares e atividade eletromiográfica (EMG) do tríceps sural. Desenho: Foi realizado um estudo experimental com distribuição aleatória dos participantes em dois grupos de intervenção, pacote de gelo (n=20) e imersão em água gelada (n=21). As variáveis independentes foram grupo experimental (pacote de gelo ou imersão em água gelada), tipo de contração (isométrica ou isocinética concêntrica), velocidade angular do teste isocinético (60 e 120°/s) e tempo de mensuração (pré- e pós-resfriamento). Variáveis dependentes foram temperatura da pele, parâmetros de desempenho muscular e atividade EMG. Métodos: Quarenta e um homens saudáveis, com média de idade (DP) de 22,15 (2,89) anos participaram do estudo. Cada grupo recebeu uma das duas modalidades de resfriamento, aplicada sobre a região da panturrilha por 20 minutos. A temperatura da pele e parâmetros do desempenho muscular dos flexores plantares e da atividade EMG dos músculos sóleo e gastrocnêmio medial e lateral foram avaliados antes e imediatamente após o resfriamento. Resultados: O pacote de gelo causou aumento no pico de torque isométrico. A atividade EMG foi reduzida em ambos os músculos sóleo e gastrocnêmio pelas duas modalidades de resfriamento durante a contração isométrica. As duas modalidades de resfriamento reduziram o pico de torque e trabalho total na contração isocinética em ambas as velocidades avaliadas. De modo geral, o pacote de gelo foi mais efetivo para reduzir a atividade EMG na contração isocinética. Conclusões: O pacote de gelo e a imersão em água gelada mostram efeitos similares sobre o desempenho muscular, o qual é dependente a ação muscular realizada. O resfriamento muscular diminui o desempenho durante a contração isocinético e o pacote de gelo aumenta o torque isométrico. Os resultados sugerem cautela quando forem realizadas atividades dinâmicas após o resfriamento, especialmente durante contrações isocinéticas máximas.
38

Desempenho e a expressão gênica do músculo esquelético humano sob treinamento físico de força e fotoestimulado por laser de baixa intensidade

Ferraresi, Cleber 27 August 2010 (has links)
Made available in DSpace on 2016-08-17T18:39:33Z (GMT). No. of bitstreams: 1 3200.pdf: 3588148 bytes, checksum: 58c00865da17881f2dd08836efbd8f2f (MD5) Previous issue date: 2010-08-27 / Universidade Federal de Minas Gerais / Contexto e Objetivos: Com base na especificidade do treinamento e das formas de sua avaliação, os ganhos de desempenho muscular dos exercícios em cadeia cinética fechada (CCF) podem não serem transferidos com a mesma proporção para outra atividade física em cadeia cinética aberta (CCA). Assim, nossos objetivos foram quantificar a transferência dos ganhos de desempenho muscular de um programa de treinamento físico de força em CCF (leg press), para a atividade de extensão do joelho (CCA) em dinamometria isocinética. Também identificar as correlações entre a 1 repetição máxima em leg press (1RMleg) e o desempenho muscular em dinamometria isocinética (DMDI) para predizê-los por meio de regressões lineares. Desenho do estudo/Materiais e métodos: Participaram 20 sujeitos do gênero masculino; clinicamente saudáveis; com padrão de atividade física iniciante ou moderada. Os sujeitos foram alocados aleatoriamente em dois grupos distintos: grupo controle (GC) e grupo treinamento (GT), o qual foi submetido a um programa de treinamento físico de força por 12 semanas em leg press. Testes de 1RMleg e DMDI avaliaram o desempenho muscular do quadríceps femoral e isquiotibiais dos grupos GT e GC no início e final da pesquisa. Testes de correlações produto-momento de Pearson e regressões lineares estabeleceram, respectivamente, as correlações e as predições da 1RMleg e DMDI. Resultados: O programa de treinamento aumentou a 1RMleg em 26% (p<0,001) mas não transferiu significativamente (p>0,05) esse ganho para o DMDI. As correlações variaram de moderadas a fortes entre 1RMleg e o DMDI. As predições variaram de 15% a 46% para o DMDI e foi de 67% para a 1RMleg. Conclusão: Apesar de identificadas correlações moderadas a fortes entre as atividades em CCF e CCA, os ganhos de desempenho muscular nas atividades de CCF podem não serem transferidos para outra atividade realizada em CCA.
39

Estudo biomecânico da preensão manual em atletas de diferentes modalidades esportivas / Biomechanic study of handgrip in athletes of different sportive modalities

Silva, Affonso Celso Kulevicz 31 August 2006 (has links)
Made available in DSpace on 2016-12-06T17:07:12Z (GMT). No. of bitstreams: 1 DISSERTACAO-Affonso Celso Kulevicz da Silva.pdf: 4394417 bytes, checksum: dd5b9db49311f3dcab96792448947fa2 (MD5) Previous issue date: 2006-08-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Handgrip can be decisive for certain sports in specific situations. This work constitutes an analysis of handgrip biomechanic variables in tests for maintaining continuous isometric and maximum interval strength in athletes that use this movement in their sport and in non-athletes. The intention is to compare the differences in characteristics among the groups, between dominant hand (DH) and non-dominant hand (NDH) in each test, in a way that identifies parameters that supply quantitative information concerning performance and training methodology, in the different kinds of sports. Participants in the study included fifty male subjects: 29 athletes that practice aikido (AI), jujutsu (JJ), judo (JU) and rowing (RO), and 21 non-athletes. The test for continuous handgrip (CT) consisted of maintaining maximum isometric force for 2 minutes, and the interval test (IT), maximum muscle contractions every 1 second (1Hz) for 4 minutes. The analysis was of maximum strength, strength measured at determined moments, final strength, percentage of normalized strength decrease and stabilization point of the strength curve. The highest levels of strength were observed in the JJ group, regardless of which test was carried out. In the tests comparing the different sports, significant statistical differences had the variables of: Fmax, F15s, F30s (DH, CT); F6s, F9s, F12s, F15s, F30s, F60s, F90s, F114,330s, F150s, F180, F210s (DH, IT) and Fmax, F3s, F6s, F9s, F12s, F15s, F180s, F210s (NDH, IT) between the NA and JJ, as well as the variables Fmax, F3s, F6s, F9s, F12s, F15s (NDH, CT) among NA, AI and JJ. In addition, significant statistical differences were observed between DH and NDH having the variables: F6s, F9s, F12s, F15s (CT, JJ); F3s, F6s, F9s, F12s, F15s, F30s, %F9s, %F30s, %F60s (CT, JU); %F9s (CT, RO); Fmax, F3s, F6s, F9s, F12s, F90, Ffinal (CT, AI); F3s, F6s, F9s, F12s, F15s, F30s, F60s, %F6s, %F9s, %F12s, %F15s, %F30s, Pestab. (IT, JJ); F114,330s, F150s, F180s, F210s, Ffinal, %F3s, %F6s, %F9s, Pestab (IT, JU); F210s, Ffinal, (IT, RO). Comparing the NA group to all the athletes in just one group (AA) significant statistical differences were found in all the strength variables for DH (regardless of the type of test) and with the variables: Fmax., F3s, F6s, F9s, F12s, F15s e F30s (NDH, CT); Fmax., F3s, F6s, F9s, F12s, F15s, F30s, F60s e F90s (NDH, IT); %F6s, %F9s, %F12s, %F15s, %F30s, %F60s (DH, CT); %F3s, %F6s (NDH, CT), %F90s, %F150s, %F180s (DH, IT); %F210s (NDH, IT). These two groups showed differences between DH and NDH with the variables: Fmax., F3s, F6s, F9s, F12s, F15s, F30s, F60s, %F9s, %F12s, %F15s, %F30s, %F60s (CT, AA); %Ftotal, Fmax, F3s, F6s, F9s, F12s, F15s, Ffinal (CT, NA); Fmax., F3s, F6s, F9s, F12s, F15s, F30s, F60s, F90s, F114,330s, F150s, F180s, F210s, Ffinal, %F3s, %F6s, %F9s, %F12s, %F15s (IT, AA); Fmax., F3s, F6s, F9s, F12s, F15s, F30s, F60s, %F114,330s, %F150s (IT, NA). The suitability for the interval muscular contraction was demonstrated by the athletes superior performance in strength. The difference found between the athletes hands in both tests indicates the necessity for work with muscular compensation. Strength decrease values can determine the time of muscular fatigue in handgrip and be part of the athlete s competition strategy. / A força de preensão manual pode ser determinante em situações específicas de certas modalidades esportivas. O presente trabalho consistiu em analisar variáveis biomecânicas da preensão manual em testes de manutenção da força isométrica contínua e intervalar máximas, em atletas que utilizam este movimento na prática esportiva e em indivíduos não atletas. Pretendeu se comparar as diferenças nas características entre os grupos, entre mão dominante (MD) e não dominante (MND) e em cada teste, de forma a identificar parâmetros que fornecessem informações quantitativas em relação ao desempenho e metodologia de treino, nas diferentes modalidades esportivas. Cinqüenta sujeitos do sexo masculino, 29 atletas das modalidades de aikidô (AI), jiu-jitsu (JJ), judô (JU) e remo (RE) e 21 não atletas (NA) participaram do estudo. O teste de preensão contínuo (TC) consistiu na manutenção da força isométrica máxima durante 2 minutos, e o teste intervalar (TI), na realização de contrações musculares máximas a cada 1 segundo (1Hz), durante 4 minutos. Analisaram-se: força máxima; força medida em instantes determinados, força final, percentual do decréscimo normalizado da força e ponto de estabilização da curva de força. Os maiores valores de força foram observados no grupo JJ, independentemente do teste realizado. Nos testes de comparação entre grupos de diferentes modalidades esportivas, foram encontradas diferenças estatisticamente significativas nas variáveis: Fmáx, F15s, F30s (MD, TC); F6s, F9s, F12s, F15s, F30s, F60s, F90s, F114,330s, F150s, F180, F210s (MD, TI) e Fmáx, F3s, F6s, F9s, F12s, F15s, F180s, F210s (MND, TI) entre os NA e JJ, bem como nas variáveis Fmáx., F3s, F6s, F9s, F12s, F15s (MND, TC) entre NA, AI e JJ. Adicionalmente, observaram se diferenças estatisticamente significativas entre MD e MND nas variáveis: F6s, F9s, F12s, F15s (TC, JJ); F3s, F6s, F9s, F12s, F15s, F30s, %F9s, %F30s, %F60s (TC, JU); %F9s (TC, RE); Fmáx, F3s, F6s, F9s, F12s, F90, Ffinal (TC, AI); F3s, F6s, F9s, F12s, F15s, F30s, F60s, %F6s, %F9s, %F12s, %F15s, %F30s, Pestab. (TI, JJ); F114,330s, F150s, F180s, F210s, Ffinal, %F3s, %F6s, %F9s, Pestab (TI, JU); F210s, Ffinal, (TI, RE). Comparando-se o grupo NA e todos os atletas juntos em um grupo (AT) foram encontradas diferenças estatisticamente significativas em todas as variáveis de força para a MD (independentemente do tipo de teste) e nas variáveis: Fmáx., F3s, F6s, F9s, F12s, F15s e F30s (MND, TC); Fmáx., F3s, F6s, F9s, F12s, F15s, F30s, F60s e F90s (MND, TI); %F6s, %F9s, %F12s, %F15s, %F30s, %F60s (MD, TC); %F3s, %F6s (MND, TC), %F90s, %F150s, %F180s (MD, TI); %F210s (MND, TI). Nestes dois grupos, constataram-se diferenças entre MD e MND nas variáveis: Fmáx., F3s, F6s, F9s, F12s, F15s, F30s, F60s, %F9s, %F12s, %F15s, %F30s, %F60s (TC, AT); %Ftotal, Fmáx, F3s, F6s, F9s, F12s, F15s, Ffinal (TC, NA); Fmáx., F3s, F6s, F9s, F12s, F15s, F30s, F60s, F90s, F114,330s, F150s, F180s, F210s, Ffinal, %F3s, %F6s, %F9s, %F12s, %F15s (TI, AT); Fmáx., F3s, F6s, F9s, F12s, F15s, F30s, F60s, %F114,330s, %F150s (TI, NA). Foi observado um melhor desempenho de força dos atletas na contração muscular intervalar, mostrando ser mais adequada aos esportes avaliados. As diferenças encontradas entre mãos nos atletas em ambos os testes indicam ser necessário um trabalho de compensação muscular. Os valores de decréscimo de força podem determinar o tempo de fadiga muscular na preensão e fazer parte da estratégia de competição dos atletas
40

Desenvolvimento de um dinamômetro biomédico ergonômico com comunicação com dispositivos móveis / Development of an ergonomic biomedical dynamometer with communication with mobile devices

Paulo, Danilo Pazian [UNESP] 12 May 2017 (has links)
Submitted by DANILO PAZIAN PAULO (danilo.ifsp.bgi@gmail.com) on 2017-07-10T16:09:54Z No. of bitstreams: 1 Versão Final V1.pdf: 6668672 bytes, checksum: d517c07a2f6f08350724000e0f4d4b64 (MD5) / Approved for entry into archive by Monique Sasaki (sayumi_sasaki@hotmail.com) on 2017-07-13T20:30:48Z (GMT) No. of bitstreams: 1 paulo_dp_me_ilha.pdf: 6668672 bytes, checksum: d517c07a2f6f08350724000e0f4d4b64 (MD5) / Made available in DSpace on 2017-07-13T20:30:48Z (GMT). No. of bitstreams: 1 paulo_dp_me_ilha.pdf: 6668672 bytes, checksum: d517c07a2f6f08350724000e0f4d4b64 (MD5) Previous issue date: 2017-05-12 / Dinamômetros biomédicos são equipamentos utilizados para medir forças exercidas pelas mãos. Com o uso deste tipo de equipamento, é possível realizar avaliações biomecânicas das mãos de pacientes que após cirurgias, acidentes ou patologias osteomioarticulares, tiveram redução na sua capacidade de exercer forças com as mãos. O objetivo deste trabalho foi a implementação de um dinamômetro biomédico ergonômico, de fácil utilização, com capacidade de comunicação com diferentes tipos de dispositivos móveis, como smartphones e tablets. O projeto realizado se constitui no aprimoramento de duas versões anteriores de dinamômetros implementadas no Laboratório de Instrumentação Eletrônica e Engenharia Biomédica da UNESP –Campus de Ilha Solteira. Testes em voluntários utilizando o dinamômetro desenvolvido e um dinamômetro comercial da marca SAEHAN, e posterior análise estatística dos dados revelam uma excelente confiabilidade intra-examinador para o dinamômetro desenvolvido, com coeficiente de correlação intraclasse médio de 0,95 entre os diferentes grupos analisados, e de 0,98 para o dinamômetro SAEHAN. A análise estatística revela também uma excelente confiabilidade concorrente para as medidas realizadas pelo dinamômetro desenvolvido em relação às do dinamômetro SAEHAN, sendo de 0,93 para mãos dominantes e 0,92 para mãos não dominantes. Assim, o dinamômetro desenvolvido é confiável, válido e comparável com o dinamômetro SAEHAN quando adotados os mesmos procedimentos de exame de preensão palmar. / Biomedical dynamometers are equipment used to measure forces exerted by the hands. Using this type of equipment, it is possible to perform biomechanical evaluations of the hands of patients that after surgery, accidents or diseases have had a reduction in the ability to exert force with their hands. The objective of this work was the implementation of an ergonomic biomedical dynamometer, easy to use, with ability to communicate with different types of mobile devices such as smartphones and tablets. The project carried out constitutes the improvement of two previous dynamometers versions implemented in the Electronic Instrumentation and Biomedical Engineering Laboratory at UNESP - Ilha Solteira. Volunteer tests using the developed dynamometer and a commercial SAEHAN dynamometer, and subsequent statistical analysis of the data revealed an excellent intra-examiner reliability for the developed dynamometer, a mean of 0,95 among different groups analyzed, and a mean of 0,98 for the SAEHAN dynamometer. The statistical analysis also revealed an excellent concurrent reliability for the measurements performed by the dynamometer developed in relation to those of the SAEHAN dynamometer, being 0,93 for dominant hands and 0,92 for non-dominant hands. Thus, the developed dynamometer is reliable, valid and comparable with the SAEHAN dynamometer when the same grip strength examination procedures were adopted.

Page generated in 0.4412 seconds