• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 217
  • 84
  • 21
  • 8
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 383
  • 383
  • 206
  • 154
  • 154
  • 130
  • 119
  • 64
  • 61
  • 54
  • 51
  • 51
  • 49
  • 46
  • 44
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Estimação de demanda em tempo real para sistemas de distribuição radiais / Real time load estimation for radial distribution systems

Julio Augusto Druzina Massignan 01 August 2016 (has links)
Para implantação de diversas funções de controle e operação em tempo real em Sistemas de Distribuição (SDs), como, por exemplo, restabelecimento de energia, é necessário um procedimento para representar a carga em tempo real. Ou seja, uma metodologia que possibilite a estimação em tempo real das demandas dos transformadores de distribuição que em geral não são monitoradas de forma direta. Para esse fim propõe-se, neste trabalho, um Estimador de Demanda em Tempo Real (EDTR) baseado em: informações off-line (consumo mensal dos consumidores e curvas de carga típicas); um algoritmo computacionalmente eficiente para cálculo de fluxo de potência baseado na estrutura de dados denominada Representação Nó-Profundidade (RNP); e nas poucas medidas disponíveis em tempo real nos SDs. O EDTR proposto opera em dois estágios: (1) Estimação Off-line das Demandas; e (2) Refinamento em Tempo Real das Demandas, executados em instantes diferentes (um de maneira off-line e outro em tempo real), de forma a prover uma estimativa das demandas dos transformadores de distribuição. Considerando somente as informações off-line, o EDTR proposto permite a estimação das demandas dos transformadores de distribuição com uma medida da incerteza da estimativa. Através do processamento das medidas disponíveis em tempo real, via um algoritmo eficiente para cálculo de fluxo de potência, o EDTR proposto permite o refinamento das estimativas off-line. Neste trabalho serão apresentados resultados de diversas simulações computacionais demonstrando a eficiência do EDTR proposto. Alguns parâmetros são avaliados quanto à influência nas estimativas do EDTR proposto, como a presença de erros grosseiros nas medidas disponíveis em tempo real e alimentadores somente com medidas de magnitude de corrente. Além disto, destaca-se a influência da qualidade das estimativas iniciais obtidas pelo Estágio (1), e a importância das hipóteses estatísticas utilizadas nesse estágio para o processo de estimação. Apresenta-se, ainda, a aplicação do EDTR proposto em um SD real brasileiro. Um teste de validação foi realizado através de uma campanha de medição em um alimentador real, que consistiu na instalação de medidores de demanda em três transformadores de distribuição para aferir a qualidade das estimativas obtidas pelo EDTR proposto. Finalmente, o EDTR proposto é aplicado em um SD real de larga escala, para aferir o desempenho computacional da metodologia implantada e as dificuldades de implantação. Vale ressaltar que sua implantação é condizente com ferramentas consolidadas nos Centros de Operação da Distribuição, como o uso do processo de agregação de cargas e o cálculo de fluxo de potência, e poucas rotinas precisam ser adicionadas para integração do EDTR. / Several real time control and operation applications for Distribution Systems (DS), such as, service restoration, require a procedure for real time load modeling. That is, a methodology for real time estimation of the distribution transformers loading which are generally not monitored. For this purpose, in this dissertation, a Real Time Load Estimator (RTLE) is proposed based on: off-line information (monthly consumption and typical load curves); a computationally efficient algorithm for power flow calculation based on the data structure called Node-Depth Encoding; and on the few available real time measurements on the distribution system. The proposed RTLE operates in two stages: (1) Off-line Load Estimation and (2) Real Time Load Refinement, performed in different moments (one off-line and the other in real time), providing the distribution transformers load estimates. Using only the offline information, the proposed RTLE allows the estimation of the loads of the distribution transformers with a measure of uncertainty. By processing the available real time measurements, using an efficient power flow calculation algorithm, the proposed RTLE refines these off-line estimates. This dissertation presents several simulations showing the efficiency of the proposed RTLE. Some parameters are evaluated and their influence on the RTLE load estimates, such as gross errors in the available real time measurements and feeders with only current magnitude measurements. Besides, it is emphasized the influence of the initial load estimates obtained from Stage (1), and the importance of the statistical hypothesis used in this stage in the load estimation process. Also, this work presents the application of the proposed RTLE in a real Brazilian DS. A validation test was performed through in-field verification in a real distribution feeder, which was executed via load meters installation in three distribution transformers to evaluate the quality of the load estimates provided by the RTLE. Finally, the proposed RTLE was tested in a real large scale DS to evaluate its computational performance and the difficult level of its implementation. It is noteworthy that its implementation is straightforward with other Distribution Operation Center tools, such as load aggregation and load flow calculation, and few routines must be added for integrating the RTLE.
232

A detecção e a localização de faltas de alta impedância em sistemas de distribuição utilizando transformadas wavelets e redes neurais artificiais / Detection and location of high impedance faults in distribution systems using wavelets transforms and artificial neural networks

Rodrigo Zempulski Fanucchi 01 September 2014 (has links)
A ocorrência de faltas em sistemas elétricos de distribuição de energia é algo indesejável, porém, inerente ao mesmo devido a sua topologia normalmente aérea. Entre essas faltas, destacam-se as de alta impedância devido às características de corrente de baixa magnitude que surgem quando de sua ocorrência. No presente trabalho, um método baseado em três módulos é apresentado para a detecção e localização de faltas de alta impedância (FAI). No Módulo 1, é realizado um monitoramento contínuo dos sinais de corrente de forma a detectar a ocorrência de uma descontinuidade que pode estar vinculada a ocorrência de uma FAI. Caso haja essa detecção, o Módulo 2 é ativado de forma a analisar se o evento é realmente uma FAI. Por último, depois de detectada a FAI, o Módulo 3 é inicializado e a localização da falta, estimada. Para possibilitar a análise do método proposto e validar os resultados obtidos, um sistema de distribuição real, em conjunto com todas as etapas do sistema de aquisição de dados, foi modelado no software ATP/EMTP. Essa modelagem foi validada a partir de dados reais obtidos quando da ocorrência em campo de um curto-circuito bifásico. Vale ressaltar que um estudo de caso referente à importância da detecção e localização de um evento relacionado a uma FAI em uma concessionária de energia foi também analisado no início do trabalho de forma a mostrar o possível impacto da localização de FAIs nos indicadores de qualidade de serviço na mesma. Pelos resultados observados, a abordagem como um todo se mostra promissora e passível de aplicação no sistema real simulado e avaliado. / The occurrence of faults in overhead distribution networks is undesirable but common based on its topology. Among these events, High Impedance Faults (HIF) is one of the most important due to the fact that it has a small magnitude current. In this dissertation, a modular three-phase method is presented to enable HIF´s detection and location in a distribution system. In the Module 1, the phase currents are monitored in order to detect a discontinuity that can be associated with a HIF´s occurrence. If the Module 1 detected a discontinuity, the Module 2 is initiated and it analyses if the event can be classified as a HIF. Finally, if the Module 2 returns the event as a HIF, the Module 3 is initiated and the possible location of the HIF is estimated. To enable analysis of the proposed method and to validate the results, a real-based distribution system and the acquisition system of a digital relay were modeled in ATP/EMTP software. In order to validate the model, a simulated twophase fault were compared with the data obtained in a real event occurred in the analyzed distribution system. In order to present the importance of detecting and locating a HIF to a distribution utility, a case study was developed in the beginning of its work. Its importance is based on the improvement of the service quality indicators. Based on the results, the proposed method seems to be promising and applicable in a real distribution system.
233

Metodologia para restabelecimento de energia em sistemas de distribuição considerando reguladores de tensão, bancos de capacitores e as características operacionais de vários tipos de chaves seccionadoras / Methodology for service restoration in distribution systems considering voltage regulators, capacitors banks and operating characteristics of various types of sectionalizing switches

Jullian Cezar Zan 20 November 2015 (has links)
Esta dissertação tem por objetivo o desenvolvimento, e implantação em computador, de uma metodologia para tratamento do problema de restabelecimento de energia em sistemas de distribuição de grande porte (com milhares de linhas, barras de carga e chaves seccionadoras), que permita a obtenção de Planos de Restabelecimento de Energia (PREs) adequados considerando a existência de reguladores de tensão, bancos de capacitores e de diferentes tipos de chaves seccionadoras. A metodologia proposta deverá considerar as características de operação de diferentes tipos de chaves seccionadoras (existência de telecomando, possibilidade de abertura com carga e/ou em curto circuito, etc.) para obtenção de PREs. Vale lembrar que usualmente as metodologias desenvolvidas para obtenção de PREs consideram a existência apenas de chaves automáticas e não automáticas, não considerando outras características de funcionamento das chaves seccionadoras. Tendo em vista que o problema a ser tratado é combinatório, com múltiplos objetivos e restrições, a metodologia proposta será baseada em Algoritmos Evolutivos, em técnicas de otimização multi-objetivo e na estrutura de dados denominada Representação Nó-Profundidade (RNP). A RNP será utilizada para representar computacionalmente, de forma eficiente, a topologia elétrica dos sistemas de distribuição. Para validar a metodologia proposta serão realizadas simulações computacionais com sistemas de distribuição reais de grande porte. / This dissertation aims to develop a methodology to provide adequate Energy Restoration Plans (ERPs) in contingency situations to large-scale distribution systems (with thousands of lines, load buses and sectionalizing switches), considering the existence of voltage regulators, capacitors banks and different types of sectionalizing switches. The proposed methodology considers the operational characteristics of different types of sectionalizing switches (existence of remote control, possibility of open-load and/or short-circuit, etc.) for the purpose of obtaining ERPs. Usually the developed methodologies consider only the existence of remotely controlled and manually controlled switches, excluding other operational characteristics of the sectionalizing switches. As the service restoration problem is combinatory with multiple objectives and constraints, the proposed methodology is based on Evolutionary Algorithms, multiobjective optimization techniques and on the data structure named Node-Depth Encoding. The Node-Depth Encoding is used to computationally represent, in an efficient way, the topology of the distribution systems. The proposed methodology is validated through computational simulations performed in real large-scale distribution systems.
234

Sistema de monitoramento para estimação de estado harmônico trifásico para sistemas de distribuição utilizando decomposição em valores singulares / Monitoring system for three-phase harmonic state estimation for distribution systems using singular values decomposition

Jáder Fernando Dias Breda 12 July 2017 (has links)
Este trabalho tem como objetivo o desenvolvimento de uma metodologia de monitoramento a partir da alocação de medidores voltada para a estimação de estado harmônico trifásica em sistemas de distribuição de energia elétrica desequilibrados. O algoritmo de estimação de estado harmônico desenvolvido tem como entrada os fasores de tensão e de corrente em pontos pré-definidos de medição sobre os alimentadores em análise. Para a alocação dos medidores, verificou-se a necessidade de a mesma ser realizada e direcionada para este problema, e um algoritmo de otimização em específico foi desenvolvido utilizando algoritmos genéticos. Para a estimação de estado harmônico, a técnica de Decomposição em Valores Singulares foi utilizada, por ser adequada a sistemas não completamente observáveis. Em relação às simulações, cargas não lineares (ou perturbadoras) foram conectadas ao longo dos alimentadores testes do IEEE de 13, 34 e 37 barras, considerando configuração trifásica assimétrica para as linhas e cargas desbalanceadas. Todas as simulações computacionais foram realizadas dispondo do programa DIgSILENT PowerFactory. Os resultados satisfatórios encontrados denotam que o desempenho do estimador desenvolvido é dependente dos pontos de medição pré-definidos a partir da alocação dos medidores realizada. Pela metodologia implementada e aplicada, o algoritmo de estimação de estado harmônico veio a corretamente calcular todas as variáveis de estado e, consequentemente, os sistemas testes em análise tornaram-se completamente observáveis para todas as fases e ordens harmônicas caracterizadas. / This research aims for the development of a monitoring methodology through the allo-cation of meters in order to perform a three-phase harmonic state estimation in unbalanced distribution systems. The harmonic state estimation algorithm developed has voltage and current phasors as inputs at predefined measurement points on the feeders about analysis. For an allocation of the meters, there was a need for it to be performed and directed to this problem, and a specific optimization algorithm was developed using Genetic Algorithms. For a harmonic state estimation, the Singular Value Decomposition technique was made, because it is suitable for systems that are not completely observable. Regarding the simulations, the non-linear (or disturbing) loads were connected along the test feeders of the IEEE of 13, 34 and 37 bus, considering the three-phase asymmetric configuration for lines and loads. All computational simulations were performed in the DIgSILENT PowerFactory software. The satisfactory results found note that the performance of the developed estimator depends on the pre-defined measurement points from the allocation of the realized meters. By the applied methodology, the harmonic state estimation algorithm came to correctly calculate all the state variables and, consequently, the test systems about analysis became fully observable for all phases and harmonic orders characterized.
235

Modelo estocástico parametrizável para o estudo de faltas de alta impedância em sistemas de distribuição de energia elétrica / Parameterizable stochastic model for high impedance fault study on electrical distribution systems

Luiz Henrique Pessôa da Costa Trondoli 22 March 2017 (has links)
As Faltas de Alta Impedância (FAI) causadas pelo rompimento de um condutor da rede primária podem trazer risco à segurança pessoal e ao patrimônio. A detecção deste defeito se faz, portanto, necessária. Não há na literatura um método que estabeleça a solução definitiva para este problema. Ainda, os estudos, quando não baseados em sinais reais, utilizam, por vezes, modelos determinísticos ou que não representam por completo as características geradas pelo defeito. Por este motivo, este trabalho propõe um modelo de falta de alta impedância que visa representar, com elevado detalhamento, a natureza do evento. O modelo desenvolvido é parametrizável para que possa representar as características dos sinais de falta e suas variações, inclusive as não determinísticas, as quais se referenciam na literatura, reproduzindo o comportamento típico de uma falta de alta impedância. O programa de simulação computacional empregado para este fim foi o ATPDraw. Para a validação do sinal gerado pelo modelo, além da comparação visual com sinais de falta reais, foi elaborado um algoritmo de detecção de FAI, o qual busca por características do fenômeno já conceituadas na literatura, com o propósito de analisar o sinal da corrente de falta gerado pelo modelo quando inserido em um sistema de distribuição de energia elétrica. Foi observada a progressão temporal do fenômeno, desde o rompimento do condutor até a formação dos arcos voltaicos. Do sinal de falta, em síntese, foram observadas características como: assimetria, variação de assimetria, ocorrência de buildup, presença e variação dos componentes harmônicos e inter-harmônicos. A observação dessa variedade de características é necessária na detecção de FAI e é coerente com o modelo proposto, já que este é o único presente na literatura capaz de reproduzi-las simultaneamente. Dos casos de falta simulados, todos foram detectados pelo algoritmo de detecção, indicando que os sinais de falta de alta impedância produzidos pelo modelo possuem as características que ele foi projetado para gerar. / High Impedance Faults (HIF) caused by primary conductor rupture can pose personal safety risk and danger to property. Detection of this event is, therefore, required. There is no proposed method in the literature that establishes a decisive solution to this problem. Studies, when not based on real signals, sometimes use deterministic models or models that do not entirely represent the event\'s characteristics. For this reason, this research proposes a high impedance fault model that intend to represent, with high level of details, the nature of this event. The developed model is parametrizable so it can represent fault signal characteristic and its variations, reproducing the typical high impedance fault behavior. The software ATPDraw was used for this purpose. For model\'s behavior and signal validation, in addition to visual comparison with real HIF signals, a detection algorithm was developed, which searches for HIF characteristics presented on literature, with the intent of analyzing the fault current signal generated by the model when inserted on an electrical distribution system. The temporal progression of the event was observed from the conductor rupture until electric arc ignition. From the fault current, characteristics such as: asymmetry, asymmetry variation, buildup, presence and variation of harmonic and inter-harmonic frequencies were analyzed. The evaluation of this variety of characteristics is needed for HIF detection and it only makes sense because the proposed model is the only one presented in literature capable of reproducing of all them simultaneously. All detection tests resulted in positive identification, confirming that the proposed HIF model possesses the intended characteristics.
236

Avaliação dos impactos de elevados níveis de penetração da geração fotovoltaica no desempenho de sistemas de distribuição de energia elétrica em regime permanente / Assessment of the steady state performance of the impacts of high penetration levels of photovoltaic generation in distribution systems

Juliana Aramizu Paludo 14 February 2014 (has links)
O emprego de geradores fotovoltaicos (FV) conectados ao sistema de distribuição de energia elétrica tem apresentado um crescimento significativo na última década. No Brasil, sua existência ainda é reduzida, entretanto a previsão é que esta aumente nos próximos anos em função das novas regulamentações estabelecidas pelas concessionárias de energia, com apoio da Agência Nacional de Energia Elétrica. O estudo das consequências trazidas pela conexão massiva de geradores FV possibilita o planejamento correto de operação do sistema de distribuição, evitando assim, a degradação da qualidade da energia elétrica fornecida aos consumidores. Dentro desse contexto, este trabalho possui como objetivo a análise da influência que um elevado nível de penetração de sistemas FV possui em um sistema de distribuição de energia elétrica. Durante as análises, foram considerados diversos geradores FV distribuídos aleatoriamente em dois sistemas de distribuição teste bastante distintos. O programa de simulação computacional empregado foi o OpenDSS. Os estudos consideraram situações de regime permanente e foram feitas abordagens empregando variações temporais, com o propósito de avaliar o comportamento e a interação entre os perfis de carga e geração FV. Os resultados mostraram a importância de considerar as variações temporais de demanda e de geração, e apontaram que o perfil de tensão em regime permanente, nível de desbalanço de tensão, perdas técnicas, regulação da tensão e desconexão dos geradores são fatores importantes que devem ser avaliados em estudos deste tipo. Além disso, mostrou-se que possíveis impactos negativos decorrentes da introdução massiva de geradores fotovoltaicos podem ser mitigados utilizando as soluções propostas ao final deste trabalho. / The employment of photovoltaic (PV) generators connected to the grid has increased significantly in the past decade. In Brazil, there are a few PV systems nowadays, but this scenario tends to change since new regulations have been established by the utilities with support of the Brazilian Electrical Energy Agency. The study of the effects caused by high penetration levels of PV generators enables the correct operation of the distribution networks and prevents the degradation of power quality provided to the consumers. In this context, the purpose of this research is to analyze the consequences caused by high-penetration levels of PV systems in distribution networks. Several distributed PV generators are considered and located randomly in two distinct distribution test feeders. The studies were carried out by using the software OpenDSS. The analysis focused on steady state studies and typical daily load and PV generation curves have been considered to evaluate the behavior and the interaction between loads and PV generation. The results have shown the importance of considering such load and power variation, and pointed out that voltage profile, voltage unbalance level, technical losses, voltage regulation and generators disconnection are important issues to be studied in situations like the ones analyzed in this work. Furthermore, possible negative impacts caused by high PV penetration levels can be mitigated by employing the potential solutions proposed in this dissertation.
237

Estudo de reativos em sistemas de distribuição de energia elétrica / Reactive power study in energy distribution systems

Fillipe Matos de Vasconcelos 22 March 2012 (has links)
Este trabalho tem o objetivo de utilizar métodos de otimização não linear a fim de desenvolver uma metodologia eficiente para alocação de bancos de capacitores visando a eliminar violações de tensão em redes de distribuição. A aplicação de capacitores em paralelo a sistemas elétricos de potência é comumente empregada com o intuito de se obter melhor controle do fluxo de potência, gerenciamento do perfil de tensão, correção do fator de potência e minimização de perdas. Tendo em vista estes benefícios, a metodologia deste trabalho se dará por meio da resolução de um problema de programação não linear associada com a aproximação linear da relação potência reativa versus tensão para determinar o número, a localização e o dimensionamento dos bancos capacitores ao longo das linhas de distribuição. Desta forma, pretende-se minimizar a injeção de reativos e reduzir as perdas ativas totais de modo que todas as restrições de operação e de carga sejam atendidas. Os resultados são avaliados pelo programa GAMS (General Algebraic Modeling System), pelo MATLAB TM (Matrix Laboratory) e por um programa elaborado em Fortran, sendo possível analisar e descrever as contribuições alcançadas pelo presente trabalho, considerando que este é um tema de grande relevância para a operação e planejamento da expansão dos sistemas elétricos de potência. / This work aims to use nonlinear optimization methods to develop an efficient methodology for capacitor banks allocation to eliminate voltage violations in distribution networks. The application of capacitors in parallel to the electric power systems are commonly employed in order to have better control of power flow, voltage profile management, power factor correction and loss minimization. To achieve these benefits, the methodology of this work will be done through the resolution of a nonlinear programming problem associated with the linear approach of Voltage Variations versus Reactive Power Variation, calculating the number, location and optimal design of capacitor banks along distribution lines. Thus, it looks forward to minimize reactive power injection and reduce losses subject to meeting the operating and the loading constraints. The results are evaluated by the program GAMS TM (General Algebraic Modeling System), by Matlab TM (Matrix Laboratory) and by a program written in FORTRAN TM, being able to analyze and describe the contributions achieved by this work, considering it is a topic of great relevance to the operation and expansion planning of electric power systems.
238

Algoritmo evolutivo computacionalmente eficiente para reconfiguração de sistemas de distribuição / Evolutionary algorithm computationally efficient for distribution system reconfiguration

Augusto Cesar dos Santos 24 April 2009 (has links)
O restabelecimento de energia em sistemas de distribuição de energia elétrica radiais geralmente envolve a reconfiguração de redes para restaurar eletricidade à(s) área(s) fora de serviço. As principais técnicas para restabelecimento de energia em sistemas de distribuição de grande porte têm sido os algoritmos evolutivos (AEs). Após a falta ter sido identificada e a zona em falta ter sido isolada do sistema, o algoritmo deve encontrar soluções em que: 1) supra com energia o maior número de consumidores possível, 2) minimize o número de operações de chaveamentos, 3) não viole restrições operacionais do sistema, 4) reduza o total de perdas resistivas, 5) a configuração da rede seja radial e, 6) obtenha tal solução em tempo real. Este projeto emprega uma nova estrutura de dados para manipular grafos produzindo exclusivamente configurações radiais e conexas, chamada representação nó-profundidade (RNP), garantindo que todas as soluções potenciais geradas pelo algoritmo satisfaçam os itens (1) e (5). Além disso, propõe-se um AE utilizando a RNP capaz de encontrar planos de restabelecimento adequados para sistemas de distribuição de larga-escala, com milhares de chaves e barras, em tempo real. / Energy restoration in radial distribution systems usually involves the network reconfiguration to restore the electricity to the out-of-service areas. The main approaches for energy restoration in large-scale distribution systems have been the evolutionary algorithms (EAs). After a fault has been identified and isolated, the algorithm must find solutions that: 1) supply energy to the larger number of consumers, 2) reduce the number of switching operations, 3) respect operational constraints of the system, 4) reduce the amount of power losses, 5) generate exclusively radial configurations and 6) find solutions in real time. This work uses a new data structure, called node-depth encoding (NDE), to manipulate graphs producing exclusively radial and connected configurations, and guaranteeing that all potential solutions generated by the algorithm satisfy items (1) and (5). Moreover, we propose an EA using the NDE that is capable of finding adequate restoration plans in real time for large-scale distribution systems, with thousands of switches and buses.
239

Reconfiguração ótima de sistemas de distribuição de energia elétrica baseado no comportamento de colônias de formigas / Optimal reconfiguration of the electric power distribution systems using a modified ant colony system algorithm

Fernando Silva Pereira 26 February 2010 (has links)
O objetivo deste trabalho é apresentar uma nova abordagem para obtenção de configurações para sistemas de distribuição de energia elétrica com o intuito de minimizar o valor de perdas ativas sem violar as restrições operacionais. Para isso, considera-se que os sistemas de distribuição estão operando em regime permanente e que suas fases estão equilibradas e simétricas, podendo o sistema ser representado por um diagrama unifilar. A reconfiguração é feita de forma a redistribuir os fluxos de corrente nas linhas, transferindo cargas entre os alimentadores e melhorando o perfil de tensão ao longo do sistema. O problema de reconfiguração do sistema pode ser formulado como um problema de programação não-linear inteiro misto. Devido à explosão combinatorial inerente a este tipo de problema, a resolução do mesmo por técnicas de otimização clássicas torna-se pouco atraente, dando espaço para técnicas heurísticas e metaheurísticas. Essas outras, mesmo não garantindo o ótimo global, são capazes de encontrar boas soluções em um espaço de tempo relativamente curto. Para a resolução do problema de reconfiguração, utilizou-se uma nova metodologia baseada no comportamento de colônias de formigas em busca de alimento na natureza. Nesta, formigas artificiais (agentes) exploram o meio ambiente (sistema de distribuição) e trocam informações para tentar encontrar a topologia que apresente os menores valores de perdas ativas. Para o cálculo das perdas, este trabalho também apresenta uma nova abordagem para resolução do problema de fluxo de potência (FP) em sistemas de distribuição radial. O fluxo de potência é uma ferramenta básica utilizada pelos centros de controle para determinar os estados e condições operacionais desses sistemas de potência. Basicamente, as metodologias empregadas para o cálculo do fluxo de potência são baseadas nos métodos clássicos de Newton ou Gauss. Mas em sistemas de distribuição de energia, devido a particularidades inerentes a estes, como a alta relação entre resistência e reatância das linhas (r/x) e a operação radial, estes métodos apresentam problemas de convergência e se tornam ineficientes na maioria das vezes. A abordagem consiste na associação dos métodos da função penalidade e de Newton. O mal-condicionamento da matriz Jacobiana de Newton é resolvido pela associação com o método da função penalidade. São apresentados testes realizados em sistemas de 5 barras, 16 barras, 33 barras, 69 barras e 136 barras para avaliar a potencialidade das técnicas propostas. Os resultados são considerados bons ou muito bons quando comparado com as técnicas existentes atualmente. / The objective of this work is to present a novel methodology for obtaining new configurations of the distribution system in order to minimize the active power losses without violating operational constraints. For this, it is considered that any distribution system is operating in a steady state and that it is balanced, therefore it can be represented by a one-line diagram. The reconfiguration is done in order to redistribute de current flows on the distribution power lines, transferring loads among the feeders and improving the voltage profile along the system. Such problem can be formulated as a mixed integer nonlinear programming problem. Due to its inherent combinatorial characteristic and since its solution by classic optimization techniques is not appealing, heuristic and metaheuristic techniques are thus better suited for its solution. Although these latter do not guarantee a global optimum, they are able to find good solutions in a relatively short time. The solution of the reconfiguration problem in this approach makes use of a novel methodology based on ant colony behavior, when these search for victuals in nature. In this technique, the artificial ants (agents) explore the environment (distribution system) and exchange information among them in order to find the topology that provides the smallest active losses. For the active losses calculation, this work also presents a novel approach for the solution of the power flow problem for radial distribution systems. The solution of the power flow problem is used by system operators in order to determine the state and operational conditions of power systems. Basically, the most common techniques used in the power flow solution are based on either Newton\'s or Gauss\' approaches. However, due to particular characteristics of distribution systems such as the high ratio of r/x and the radial topology, these methods present convergence problems and are not efficient in most of the cases. Thus, this novel technique consists in associating Newton\'s and the penalty function approaches. The matter of the ill-conditioned Jacobian matrix in Newton\'s method is overcome with the penalty function method. Some tests performed in different systems are then presented in order to assess the effectiveness of both proposed techniques.
240

Computação em nuvem no contexto das smart grids: uma aplicação para auxílio à localização de faltas em sistemas de distribuição / Cloud computing in the smart grids context: an application to aid fault location in distribution systems

Jeovane Vicente de Sousa 21 September 2018 (has links)
A computação em nuvem tem sido vislumbrada como a principal tecnologia capaz de integrar e gerenciar os diversos sistemas envolvidos em uma Smart Grid. Nesse sentido, esta pesquisa tem por objetivo desenvolver uma infraestrutura de computação em nuvem capaz de armazenar e manipular dados em sistemas de distribuição. Analisando a infraestrutura das principais aplicações que utilizam computação em nuvem nesse contexto, foi proposta uma arquitetura com serviços essenciais, que pode ser estendida, para abrigar serviços e aplicações voltadas aos sistemas de distribuição inteligentes. A partir dessa proposta, uma infraestrutura de computação em nuvem foi implementada, utilizando ferramentas open source. Essa infraestrutura permitiu o desenvolvimento de uma nova aplicação para auxílio à localização de faltas, utilizando mineração de dados sobre os dados provenientes de smart meters, que é capaz de reduzir o problema da múltipla estimação nos sistemas de distribuição radial, auxiliando na definição do ramal faltoso. Para isso, uma versão otimizada da ferramenta de mineração de dados DAMICORE (Data Mining of Code Repositories) foi implementada estendendo os serviços básicos da arquitetura proposta. A aplicação desenvolvida foi avaliada utilizando centenas de simulações de falta sujeitas ao problema da múltipla estimação, aplicadas ao longo de um alimentador de testes, sendo capaz de reduzir mais de 80% das extensões de falta susceptíveis ao problema da múltipla estimação. Os resultados apresentados mostraram que a arquitetura proposta e a infraestrutura de computação em nuvem desenvolvida são capazes de suportar novas aplicações para os sistemas de distribuição inteligentes contribuindo para o desenvolvimento das smart grids e para a difusão da computação em nuvem nesse contexto. Como contribuição adicional, a aplicação em nuvem desenvolvida permitirá reduzir a múltipla estimação na localização de faltas em sistemas de distribuição. / Cloud computing has been envisioned as the main technology capable to integrate and manage many systems on a Smart Grid. Thus, this research aims to develop a cloud computing infrastructure to store and manipulate smart distribution system data. By analyzing the infrastructure of the main applications using cloud computing for smart distribution systems, an extensible architecture with essential services was proposed to host smart distribution systems services and applications. Based on this proposition, a cloud computing platform was developed using open source tools. A new application to reduce multiple estimation for fault location in radial distribution systems using datamining techniques over smart meter data was implemented using this infrastructure. An optimized version of the datamining tool known as DAMICORE (Data Mining of Code Repositories) was implemented as an extension to the proposed architecture basic services. The new cloud application was tested using hundreds of fault simulations through a test feeder, being able to reduce the line extensions with multiple estimation by more than 80% in the simulated fault cases. The results show that the proposed cloud computing architecture and infrastructure enable new smart distribution systems applications, contributing to the development of smart grids and diffusion of cloud computing in this context. As an additional contribution, the cloud application developed will help to reduce the multiple estimation for fault locations in distribution systems.

Page generated in 0.1068 seconds