• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • 28
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 94
  • 94
  • 84
  • 25
  • 24
  • 23
  • 21
  • 21
  • 20
  • 19
  • 18
  • 16
  • 16
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estimativa da retenção de água no solo a partir do uso de equipamentos não convencionais, redes neurais artificiais e funções de pedotransferência / Water retention soil estimate using nonconventional equipment, artificial neural networks and pedotransfer functions

Angelotti Netto, Antonio 06 September 2007 (has links)
O desenvolvimento econômico e o aumento da produtividade agrícola intensificaram o uso de produtos químicos nas lavouras. Quando se pretende quantificar o impacto ambiental de tal uso é necessário empregar modelos que descrevam o fluxo de água e solutos na região não saturada do solo. Para esse fim, um dos parâmetros mais eficazes é conhecer a retenção de água no solo. O objetivo deste trabalho foi desenvolver funções de pedotransferência (FPTs) que estimassem a partir de análise em redes neurais artificiais (RNAs) a retenção de água nos solos da microbacia hidrográfica do ribeirão Canchim, município de São Carlos, SP. Os atributos físicos, textura (argila, silte e areia), densidade e resistência à penetração dos solos: LVAd, LVe, LVdf e NVef, manejados com e sem cobertura vegetal e sob mata foram determinados com equipamentos não convencionais na Embrapa Instrumentação Agropecuária em São Carlos, SP. Esses parâmetros foram utilizados como variáveis de entrada nas duas redes neurais artificiais. Foram obtidas, ainda, as curvas de retenção de água no solo por meio da câmara de pressão de Richards e da tomografia computadorizada, além da porosidade total e da condutividade hidráulica não saturada. O analisador granulométrico de solos e o penetrômetro associado a TDR possibilitaram a obtenção de um grande número de dados. Os atributos físicos dos solos apresentaram grande variabilidade em função da constituição granulométrica e manejos adotados. As RNAs foram eficientes no desenvolvimento de FPTs capazes de estimar a retenção de água com base em propriedades básicas de solo obtidas em grande número. / Economic development and increasing agricultural productivity have intensified the use of chemical products in farming. The quantification environmental impact of these products requires the use of models that describe the flow of water and solutes in the unsaturated region of the soil. For this purpose, one of the most effective parameters belong to the water retention curve of the soil. The purpose of this work was to develop pedotransfer functions (PTFs) to estimate the retention of water by soils of the hydrographic microbasin of the Canchim river, in the municipality of São Carlos, state of São Paulo, Brazil, based on artificial neural networks (ANNs). The physical attributes, granulometry (clay, silt and sand), density and resistance to penetration of LVAd, LVe, LVdf and NVef soils, managed with and without vegetal cover and under forest, were determined using nonconventional equipment at Embrapa Instrumentação Agropecuária in São Carlos, SP. These parameters were used as input variables for two artificial neural networks. The soils\' water retention curves were also obtained using a Richards pressure chamber and computed tomography, as well as their total porosity and unsaturated hydraulic conductivity. A soil granulometric analyzer and a penetrometer allied to TDR provided a large number of data. The soils\' physical attributes displayed a wide variability as a function of their granulometric constitution and adopted managements. The ANNs were effective in developing PTFs able to estimate the water retention based on the large number of basic soil properties.
82

Desenvolvimento de uma sonda TDR helicoidal para uso em conjunto com o ensaio CPT / Developing a coil TDR probe to use together with the CPT test

Guerrero Doria, Katerin 21 August 2015 (has links)
A reflectometria no domínio do tempo permite estimar o teor de umidade de um meio através da sua correlação com a constante dielétrica. Uma sonda helicoidal TDR, que pode ser cravada em conjunto outros ensaios de penetração in situ para a estimativa do teor de umidade em diversas profundidades, tem aplicação interessante para a investigação geotécnica do subsolo. No presente trabalho, uma sonda TDR foi adaptada e utilizada em conjunto ao ensaio CPT para caracterização de um perfil de solo arenoso não saturado que ocorre na região de Bauru (SP). A calibração dessa sonda foi feita em laboratório especificamente para esse solo. As equações de calibração que mostraram os melhores resultados foram definidas correlacionando a constante dielétrica, condutividade elétrica aparente e a massa específica seca com o teor de umidade. Com o intuito de melhorar a acurácia na determinação do teor de umidade em campo e eliminar possíveis interferências no registro da onda eletromagnética, foram efetuadas modificações em algumas características do projeto original dessa sonda. Tais modificações consistiram em separar os eletrodos condutores e as partes metálicas da sonda, e eliminar o cabo coaxial de extensão, conectando a sonda diretamente a um cabo coaxial de 12 m de comprimento. Tais mudanças levaram a uma melhoria significativa na determinação do perfil de teor de umidade do local estudado. Os valores de teor de umidade de campo determinados usando o TDR ao longo de 8 m de profundidade foram comparados com os valores de referência obtidos de amostras deformadas retiradas com trado mecânico. O erro médio na estimativa do perfil de teor de umidade gravimétrico utilizando a sonda TDR helicoidal foi de 1.61%, na última campanha de ensaios realizados. Os resultados dessa pesquisa indicam que esta ferramenta é adequada para estimar do perfil de teor de umidade para uso em conjunto com o ensaio CPT. / The time domain reflectometry allows estimating the moisture content of a medium by means of its correlation with the dielectric constant. A coil TDR probe, which can be driven into the ground together with others in situ penetration tests, can be used to estimate the moisture content at different depths. It is an interesting approach for geotechnical site characterization. In this work, a coil TDR probe was adapted and used in combination with the CPT test for the site characterization of an unsaturated sandy soil profile which occurs in the region of Bauru (SP). The probe calibration was performed in laboratory specifically for that soil. The calibration equation, which presented the best results, were defined correlating the dielectric constant, electrical conductivity and dry density with the moisture content. In order to improve the accuracy for determining the water content in the field and to eliminate possible interference on the electromagnetic wave registration, modifications were made in some characteristics of the original design of this probe. Such modifications consisted in separating the conductive electrodes from the metal parts of the probe, and eliminating the coaxial extension cable, connecting the probe directly to a coaxial cable 12 m long. Such changes have led to a significant improvement in the determination of the moisture content profile of the studied site. The moisture content values determined in situ by using the TDR along 8 m depth were compared with reference values obtained from disturbed soil samples collected using mechanical augers. The root mean square error of the gravimetric water content profile using the TDR coil probe was 1.61% in the last test campaign. The results of this research indicate that this tool is suitable to estimate the gravimetric moisture content together with the CPT test.
83

Capteurs de corrosion à fibre optique pour la surveillance répartie d’ouvrages en béton armé / Distributed corrosion sensing in reinforced concrete structures by optical fiber sensing

Ali Alvarez, Shamyr Sadat 19 September 2016 (has links)
La corrosion des armatures de renforcement des structures en béton représente un enjeu socio-économique majeur. Sa détection et le suivi de son évolution constituent un défi pour la recherche appliquée. Les techniques standards non destructives de détection de corrosion mettent en œuvre des procédés indirects tels la mesure d’impédance, de potentiels, ou par ultrasons. Leurs capacités d’auscultation sont limitées dans l’espace (notamment en profondeur), leur coût reste élevé dans un contexte de maintenance périodique et elles conduisent à des paramètres d’interprétation complexe. Des progrès sont nécessaires dans la détection et l’analyse fiable de la progression des processus de corrosion. Dans ce travail, nous présentons une nouvelle méthode pour détecter la corrosion et le suivi de son évolution, basée sur l’observation directe des changements intervenant à l’interface fer-béton par Capteur à Fibre Optique (CFO). L'attaque par corrosion de la surface de l'armature dépend de plusieurs paramètres électrochimiques (température, pH, carbonatation, présence de chlorures, contamination biologique, etc.). Deux comportements mécaniques à l'interface fer-béton sont distingués. Dans le premier cas (carbonatation), le produit d'oxydation du métal reste à l'interface et augmente la pression interne, pouvant conduire à la fissuration de la couche de béton extérieure. Dans le second cas (piqures), les ions métalliques sont évacués hors de la structure avec comme conséquence une réduction de section des barres d'armature (affaiblissement du renforcement). Un CFO innovant est proposé dans le but de localiser et quantifier les deux types de corrosion précités. Le principe consiste à observer l’impact direct de la corrosion sur l’état de déformation d’une fibre optique préalablement précontrainte par construction. Deux procédés métrologiques sont étudiés : Bragg et réflectométrie fréquentielle (Optical Frequency-Domain Reflectometry - OFDR). Des tests de corrosion accélérée montrent la faisabilité du procédé. Une procédure de fabrication simplifiée et à coût optimisé est proposée pour la surveillance in situ et répartie des structures de génie civil, dans une perspective future de maintenance conditionnée. / Corrosion of reinforced bars (rebars) in concrete structures remains a major issue in civil engineering works, being its detection and evolution a challenge for the applied research. Usual non-destructive corrosion detection methods involve impedance, potential or ultra-sonic indirect measurements of complex interpretation. Besides, they are restricted to near-surface examinations and the maintenance cost is still high (scheduled maintenance). Many efforts remain to be done to survey the onset and progression of corrosion processes in a reliable way. In this work, we present a new methodology to detect the onset of corrosion and to monitor its evolution, based on the direct observation of rebar–concrete interface changes by the use of an Optical Fiber Sensor (OFS). The corrosion attack over rebar surface depends on several physical, chemical and electrochemical parameters (temperature, pH, presence of chlorides/CO2, biological contamination, etc.). Two types of mechanical behavior and described. In the first case (carbonation), metal oxidation products stay at the interface and increase internal pressure, potentially leading to a crack of the external concrete layer. In the second case (pitting), metal ions are evacuated out of the structure, leading to a reduction of the rebar section (structural weakness). An innovative sensor design is proposed with the purpose of localizing and quantifying the amount of both corrosion types. The basic principle consists in measuring the impact of corrosion over the state of strain of a prestressed optical fiber. Two metrological techniques are used: Fiber Bragg Grating (FBG) and Optical Frequency-Domain Reflectometry (OFDR). Accelerated corrosion tests were performed in electrolytic solutions for both kinds of corrosion types (pitting and carbonation) and provide a proof-of-concept for the technique. A low-cost, simplified manufacturing procedure is proposed with the aim to provide distributed and in situ Structural Health Monitoring (SHM), suitable for future Condition-Based Maintenance (CBM) of civil engineering concrete structures.
84

Contribution à l'étude de solutions non destructives pour la détection et la localisation de défauts électriques dans les structures électroniques 3D / Contribution to the study of non-destructive solutions for the detection and the localization of electrical defects in 3 D electronic structure

Courjault, Nicolas 17 June 2016 (has links)
L'objectif de la thèse fut d'étudier plusieurs techniques d'analyse de défaillance (Microscopie magnétique, Thermographie à détection synchrone, Tomographie à Rayons X, Réflectométrie Temporelle) sur leur propriété de localisation de défaut électrique (Court-circuit, circuit ouvert, ouvert résistif, etc.) sur des systèmes et composants électroniques 3D. Des possibilités d'évolution de ces techniques sont suggérées afin de permettre d'assurer la localisation des défauts dans ces nouveaux composants électroniques. Ceci passe notamment par la mise en place d'analyses magnétiques sur des échantillons inclinés ainsi que par l'introduction d'une imagerie de phase, et d'amplitude magnétique. Ce travail a également permis de proposer le couplage d'informations obtenues par microscopie magnétique et tomographique à rayons X dont l'ensemble serait piloté par simulation magnétique 3D. / The thesis purpose was to explore several failure analysis techniques (Magnetic microscopy, Lock-in Thermography, X-rays Tomography, Time Domain Reflectometry) on their capabilities to localize the electrical defect (Short circuit, open circuit, resistive open, etc.) on 3D electronic component and system. Assessment possibilities of these techniques are suggested in order to ensure the defect localization in these new components. In particular, implementations of magnetic analysis in tilted sample as well as introduction of phase and amplitude magnetic images have been realized. This work also proposes to couple information obtain from magnetic microscopy to X-rays Tomography where the all system would be driven by 3D magnetic simulation
85

Desenvolvimento de uma sonda TDR helicoidal para uso em conjunto com o ensaio CPT / Developing a coil TDR probe to use together with the CPT test

Katerin Guerrero Doria 21 August 2015 (has links)
A reflectometria no domínio do tempo permite estimar o teor de umidade de um meio através da sua correlação com a constante dielétrica. Uma sonda helicoidal TDR, que pode ser cravada em conjunto outros ensaios de penetração in situ para a estimativa do teor de umidade em diversas profundidades, tem aplicação interessante para a investigação geotécnica do subsolo. No presente trabalho, uma sonda TDR foi adaptada e utilizada em conjunto ao ensaio CPT para caracterização de um perfil de solo arenoso não saturado que ocorre na região de Bauru (SP). A calibração dessa sonda foi feita em laboratório especificamente para esse solo. As equações de calibração que mostraram os melhores resultados foram definidas correlacionando a constante dielétrica, condutividade elétrica aparente e a massa específica seca com o teor de umidade. Com o intuito de melhorar a acurácia na determinação do teor de umidade em campo e eliminar possíveis interferências no registro da onda eletromagnética, foram efetuadas modificações em algumas características do projeto original dessa sonda. Tais modificações consistiram em separar os eletrodos condutores e as partes metálicas da sonda, e eliminar o cabo coaxial de extensão, conectando a sonda diretamente a um cabo coaxial de 12 m de comprimento. Tais mudanças levaram a uma melhoria significativa na determinação do perfil de teor de umidade do local estudado. Os valores de teor de umidade de campo determinados usando o TDR ao longo de 8 m de profundidade foram comparados com os valores de referência obtidos de amostras deformadas retiradas com trado mecânico. O erro médio na estimativa do perfil de teor de umidade gravimétrico utilizando a sonda TDR helicoidal foi de 1.61%, na última campanha de ensaios realizados. Os resultados dessa pesquisa indicam que esta ferramenta é adequada para estimar do perfil de teor de umidade para uso em conjunto com o ensaio CPT. / The time domain reflectometry allows estimating the moisture content of a medium by means of its correlation with the dielectric constant. A coil TDR probe, which can be driven into the ground together with others in situ penetration tests, can be used to estimate the moisture content at different depths. It is an interesting approach for geotechnical site characterization. In this work, a coil TDR probe was adapted and used in combination with the CPT test for the site characterization of an unsaturated sandy soil profile which occurs in the region of Bauru (SP). The probe calibration was performed in laboratory specifically for that soil. The calibration equation, which presented the best results, were defined correlating the dielectric constant, electrical conductivity and dry density with the moisture content. In order to improve the accuracy for determining the water content in the field and to eliminate possible interference on the electromagnetic wave registration, modifications were made in some characteristics of the original design of this probe. Such modifications consisted in separating the conductive electrodes from the metal parts of the probe, and eliminating the coaxial extension cable, connecting the probe directly to a coaxial cable 12 m long. Such changes have led to a significant improvement in the determination of the moisture content profile of the studied site. The moisture content values determined in situ by using the TDR along 8 m depth were compared with reference values obtained from disturbed soil samples collected using mechanical augers. The root mean square error of the gravimetric water content profile using the TDR coil probe was 1.61% in the last test campaign. The results of this research indicate that this tool is suitable to estimate the gravimetric moisture content together with the CPT test.
86

Estimativa da retenção de água no solo a partir do uso de equipamentos não convencionais, redes neurais artificiais e funções de pedotransferência / Water retention soil estimate using nonconventional equipment, artificial neural networks and pedotransfer functions

Antonio Angelotti Netto 06 September 2007 (has links)
O desenvolvimento econômico e o aumento da produtividade agrícola intensificaram o uso de produtos químicos nas lavouras. Quando se pretende quantificar o impacto ambiental de tal uso é necessário empregar modelos que descrevam o fluxo de água e solutos na região não saturada do solo. Para esse fim, um dos parâmetros mais eficazes é conhecer a retenção de água no solo. O objetivo deste trabalho foi desenvolver funções de pedotransferência (FPTs) que estimassem a partir de análise em redes neurais artificiais (RNAs) a retenção de água nos solos da microbacia hidrográfica do ribeirão Canchim, município de São Carlos, SP. Os atributos físicos, textura (argila, silte e areia), densidade e resistência à penetração dos solos: LVAd, LVe, LVdf e NVef, manejados com e sem cobertura vegetal e sob mata foram determinados com equipamentos não convencionais na Embrapa Instrumentação Agropecuária em São Carlos, SP. Esses parâmetros foram utilizados como variáveis de entrada nas duas redes neurais artificiais. Foram obtidas, ainda, as curvas de retenção de água no solo por meio da câmara de pressão de Richards e da tomografia computadorizada, além da porosidade total e da condutividade hidráulica não saturada. O analisador granulométrico de solos e o penetrômetro associado a TDR possibilitaram a obtenção de um grande número de dados. Os atributos físicos dos solos apresentaram grande variabilidade em função da constituição granulométrica e manejos adotados. As RNAs foram eficientes no desenvolvimento de FPTs capazes de estimar a retenção de água com base em propriedades básicas de solo obtidas em grande número. / Economic development and increasing agricultural productivity have intensified the use of chemical products in farming. The quantification environmental impact of these products requires the use of models that describe the flow of water and solutes in the unsaturated region of the soil. For this purpose, one of the most effective parameters belong to the water retention curve of the soil. The purpose of this work was to develop pedotransfer functions (PTFs) to estimate the retention of water by soils of the hydrographic microbasin of the Canchim river, in the municipality of São Carlos, state of São Paulo, Brazil, based on artificial neural networks (ANNs). The physical attributes, granulometry (clay, silt and sand), density and resistance to penetration of LVAd, LVe, LVdf and NVef soils, managed with and without vegetal cover and under forest, were determined using nonconventional equipment at Embrapa Instrumentação Agropecuária in São Carlos, SP. These parameters were used as input variables for two artificial neural networks. The soils\' water retention curves were also obtained using a Richards pressure chamber and computed tomography, as well as their total porosity and unsaturated hydraulic conductivity. A soil granulometric analyzer and a penetrometer allied to TDR provided a large number of data. The soils\' physical attributes displayed a wide variability as a function of their granulometric constitution and adopted managements. The ANNs were effective in developing PTFs able to estimate the water retention based on the large number of basic soil properties.
87

Aplicação da reflectometria no domínio do tempo (TDR) na estimativa da condutividade elétrica da solução do solo e de concentrações de nitrato, potássio e cloreto em coluna de solo não saturado / Applying Time domain reflectometry (TDR) on estimating electrical conductivity and nitrate, potassium and chloride concentrations under unsaturated soil columns conditions

Isaac de Matos Ponciano 17 January 2012 (has links)
Devido à importância do monitoramento da composição iônica da solução do solo, no que diz respeito ao meio ambiente e ao manejo da fertirrigação, associada às limitações práticas dos métodos tradicionais de sua determinação é crescente a procura por um método confiável que possibilite o monitoramento desta composição em tempo real e em curtos intervalos de tempo. Neste sentido a TDR tem sido uma alternativa viável. O presente trabalho objetivou, pelo uso da TDR, avaliar o desempenho de sete modelos na determinação da CEw; relacioná-los com a concentração dos íons potássio nitrato e cloreto avaliando os modelos em determinar a concentração dos íons; e por fim monitorar e determinar a concentração destes íons na água lixiviada em coluna de solo não saturado. O trabalho foi divido em dois experimentos, no primeiro os modelos foram calibrados em colunas de solo sendo formado por 24 tratamentos composto por 4 faixas de umidade volumétrica e 6 concentrações da solução de KCl. Para cada coluna de solo era realizada uma leitura com a TDR ( e CEa) e a CEw na solução do solo era determinada por condutivímetro de mesa, nesta solução foram determinadas as concentrações de potássio e cloreto. No segundo experimento o mesmo procedimento foi realizado, entretanto, foi aplicado KNO3 e determinados potássio e nitrato. Desta forma, foi possível calibrar os modelos para a estimativa da CEw, e para determinação das concentrações dos íons potássio, nitrato e cloreto. Os modelos foram avaliados pelos coeficientes de determinação (R²) e exatidão (d), pela estimativa do erro padrão (EEP) e, ainda, foram classificados de acordo com o índice c, produto dos dois coeficientes citados. Os resultados mostram que os modelos de Rhoads et al. (1976) e Vogeler et al. (1996) se ajustam melhor para solos com características texturais argilosas sendo classificados como Ótimos métodos para a determinação da CEw, tanto pela aplicação de KCl como pela aplicação de KNO3 via água de irrigação. Na estimativa da CEw no solo arenoso os modelos de Munõz-Carpena et al. (2005), Mualen e Friedman (1991), Vogeler et al. (1996) e Rhoads et al. (1976) apresentam melhores ajustes na determinação da CEw, sendo classificados com Muito bom. Na determinação do potássio pelos modelos avaliados o melhor ajuste se dá pela associação da relação K-CEw do tipo potência aplicada para solos argilosos e linear para solos arenosos, apresentando classificação de: Ótimo e Muito bom, respectivamente. Para o cloreto e o nitrato o melhor ajuste se dá pela relação de CEw-Cl e CEw-NO do tipo linear, apresentando classificação de Muito Bom e Ótimo respectivamente. A TDR é uma técnica confiável no monitoramento da concentração dos íons potássio e cloreto lixiviados no perfil do solo. / There is a growing demand for a reliable method applied to monitoring ionic composition of soil solution in real-time and short time intervals, due the importance to environmental sustainability and fertigation management and limitations of traditional methods for determination. Time domain reflectometry (TDR) is often considered a viable alternative to traditional methods. Consequently, this research looks for using TDR evaluate the performance of seven mathematical models for determining electrical conductivity (CEw) by comparing simulated and measured concentrations of potassium, nitrate and chloride, and to monitor and determine the concentration of these ions in water leached from unsaturated soil columns. The research was carried out under two experiments conditions. In the first experiment the models were calibrated with input data from 24 soil columns consisting of four soils with six different KCl concentrations. For each soil column CEw was determined by both TDR ( and CEa readings) and the CEw of soil solution was determined by direct measurements of potassium and chloride concentrations. In the second experiment the procedure was the same, but with KCl being replaced with KNO3. This was possible to calibrate the models to estimate the CEw, and to determine potassium, nitrate and chloride ions concentrations. The models were ranked using the c-index, the coefficient of determination (R²) and estimated standard error (ESE). The results showed were Rhoads et al. (1976) and Vogel et al. (1996) classified as \"Great\" for the CEw determination associated with the application of both KCl and KNO3 to irrigation water in clay soils. For estimating CEw in sandy soils, the models Muñoz-Carpena et al. (2005), Mualen and Friedman (1991), Vogel et al. (1996) and Rhoads et al. (1976) were classified as \"Very Good.\" The relationship between CEw and potassium concentration was best represented by a power function in clay soils, and a linear function in sandy soils, with index of \"Great\" and \"Very Good\", respectively. For chloride and nitrate, the best fits were obtained by representing the CEw-Cl and CEw-NO3 relationships with linear functions, which were classified as Very Good and Good, respectively. TDR proved to be a reliable technique for monitoring the concentration of potassium and chloride ions leached in soil profiles.
88

Simulace monitoringu optické trasy / Simulation of optical route monitoring

Mlejnek, Zbyněk January 2010 (has links)
Monitoring optical line for a long term monitoring and evaluating both transfer quality and running reliability of optical line links' physical layer (optical cable routes) fiber optical transfer systems. Monitoring indicates any kind of security erosion of transmission medium incited by either "natural" climatic and mechanical environmental effects, indeliberated cable violation (building operation) or by intended intervention into transfer path.
89

Propustnost pískovcových povrchů a pohyb vody v mělkých zónách skalních měst / Permeability of sandstone surfaces and water flow in shallow zone of ruiniform sandstone landscape

Sysel, Ondřej January 2020 (has links)
Water in porous rocks (e.g. sandstone) plays a fundamental role in their disintegration. However, the places where water enters the sandstone rocks are somewhat overlooked. At two sites in the Český ráj region, I use Karsten tube to measure capillary water absorption (CWA) of natural sandstone exposures and, using TDR (Time Domain Reflectometry) method, I study movement of water in a shallow zone of ruiniform sandstone landscape. The CWA differed up to four orders of magnitude at a distance of tens of meters, mostly depending on the type of the surface. The highest CWA was measured at highly weathered surfaces, the second most absorbent were less weathered surfaces covered with a biologically-initiated rock crust. The horizontal surfaces on the tops of the rock formations were even less absorbent, probably due to clogging by fine particles from soil. Surfaces covered with iron crust were the least absorbent. The differences between those surfaces are significant. After simulated infiltration, the maximum rate of the propagation of the wet front in the sandstone was from 5,5.10-6 do 1,9.10-4 m.s-1 measured by TDR. The water propagated at this rate only to a certain depth (the first tens of cm), but then the propagation stopped or slowed down rapidly. From a long-term measurement of volumetric...
90

Optical Frequency Domain Interferometry for the Characterization and Development of Complex and Tunable Photonic Integrated Circuits

Bru Orgiles, Luis Alberto 28 March 2022 (has links)
[ES] Esta tesis aborda la caracterización de circuitos fotónicos integrados (PIC) usando interferometría óptica en el domino de las frecuencias (OFDI). OFDI tiene una implementación razonablemente simple e interroga al dispositivo bajo test (DUT) proporcionando su respuesta en el dominio del tiempo, en la que los distintos caminos ópticos seguidos por la luz se manifiestan en contribuciones que contienen información de posición, amplitud y fase. Junto con un "setup" OFDI construido en nuestros laboratorios y estructuras de test integradas que involucran anillos resonantes, interferómetros, etc., proponemos e implementamos técnicas para obtener parámetros ópticos cruciales tales como el índice de grupo, dispersión cromática, rotación de polarización y pérdidas de propagación en guías de onda. También para caracterizar acopladores ópticos. Se realizan evaluaciones directas de fase óptica en diferentes experimentos para, entre otras aplicaciones, caracterizar efectos de calor en chips. En la culminación de la tesis, se aborda la integración conjunta de los interferómetros de OFDI junto con el DUT, concibiéndolo como una estructura de caracterización integrada. El uso de guías de onda integradas proporciona una alta estabilidad y adaptación al DUT, además de un mecanismo inherente de compensación de la dispersión. Se realiza un análisis y prueba de concepto experimental caracterizando un "arrayed waveguide grating" en tecnología de nitruro de silicio. Seguidamente, se da un paso adelante proponiendo una arquitectura interferométrica de tres brazos novedosa que permite reducir la complejidad de la medida. Se lleva a cabo una validación experimental amplia usando distintos equipos de laboratorio, acoplamiento horizontal y vertical al chip, y diferentes DUTs en tecnologías de nitruro de silicio y "silicon-on-insulator". / [CAT] Aquesta tesi aborda la caracterització de circuits fotònics integrats (PIC) usant interferometria òptica al domini de les freqüències (OFDI). OFDI té una implementació raonablement simple i interroga el dispositiu sota test (DUT) proporcionant la seva resposta en el domini del temps, en què els diferents camins òptics seguits per la llum es manifesten en contribucions que contenen informació de posició, amplitud i fase. Juntament amb un "setup" OFDI construït als nostres laboratoris i estructures de test integrades que involucren anells ressonants, interferòmetres, etc., proposem i implementem tècniques per obtenir paràmetres òptics crucials com ara l'índex de grup, dispersió cromàtica, rotació de polarització i pèrdues de propagació en guies d'ona. També per caracteritzar acobladors òptics. Es fan avaluacions directes de fase òptica en diferents experiments per, entre altres aplicacions, caracteritzar efectes de calor en xips. A la culminació de la tesi, s'aborda la integració conjunta dels interferòmetres d'OFDI juntament amb el DUT, concebent-ho com una estructura de caracterització integrada. L'ús de guies d'ona integrades proporciona una alta estabilitat i adaptació al DUT, a més d'un mecanisme inherent de compensació de la dispersió. Es realitza una anàlisi i prova de concepte experimental caracteritzant un "arrayed waveguide grating" en tecnologia de nitrur de silici. Seguidament, es fa un pas avant proposant una arquitectura interferomètrica de tres braços nova que permet reduir la complexitat de la mesura. Es du a terme una validació experimental àmplia usant diferents equips de laboratori, acoblament horitzontal i vertical al xip, i diferents DUTs en tecnologies de nitrur de silici i "silicon-on-insulator". / [EN] This PhD thesis covers the characterization of complex photonic integrated circuits (PIC) by using Optical Frequency Domain Interferometry (OFDI). OFDI has a fairly simple implementation and interrogates the device under test (DUT) providing its time domain response, in which the different optical paths followed by light manifest in contributions with position, amplitude and phase information. Together with a working OFDI setup built in our laboratory and integrated test structures involving devices such as ring resonators, interferometers, etc., we propose and implement techniques to get crucial optical parameters such as waveguide group refractive index, chromatic dispersion, polarization rotation, and propagation loss. Also, to characterize optical couplers. Direct optical phase assessment is made in different experiments permitting, amongst others, the characterization of on-chip heat effects. In the culmination of the thesis, the co-integration of the OFDI interferometers with the DUT is addressed, conceiving it as an integrated characterization structure. The use of integrated waveguides provide high stability and adaptation to the DUT, as well as an inherent dispersion de-embedding mechanism. It is provided analysis and experimental proof of concept with an arrayed waveguide grating as DUT in a silicon nitride platform. A considerable leap forward is then taken by proposing a novel three-way interferometer architecture, reducing the measurement complexity. Wide experimental validation is carried out using different laboratory equipment, horizontal and vertical chip coupling, and different DUTs in silicon nitride and silicon-on-insulator. / Bru Orgiles, LA. (2022). Optical Frequency Domain Interferometry for the Characterization and Development of Complex and Tunable Photonic Integrated Circuits [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/181635 / TESIS

Page generated in 0.1 seconds