• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 334
  • 16
  • 9
  • 9
  • 9
  • 9
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 359
  • 248
  • 94
  • 80
  • 69
  • 56
  • 54
  • 54
  • 51
  • 51
  • 50
  • 44
  • 43
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Influência da variação da intensidade de luz, para uma mesma exposição radiante, no comportamento mecânico de uma resina convencional e de uma resina de baixa contração / Influence of photoactivation modes, with the same radiant exposure, on mechanical properties of a convencional and a low-shrinkage composite

Mariana Rodrigues Gonzalez 08 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo teve como objetivo avaliar a influência da variação da intensidade de luz, para uma mesma exposição radiante, na resistência à flexão, na microdureza e na resistência à tração diametral de uma resina convencional e de uma resina de baixa contração. Para a confecção dos corpos de prova foram utilizadas as resinas Filtek Z250 (3M ESPE) e Filtek P90 LS (3M ESPE) fotoativadas por meio dos seguintes protocolos: Convencional (400mW/cm por 60 s), Média intensidade (700mW/cm por 34 s) e Alta intensidade (950mW/cm por 26 s). Todos os corpos de prova receberam a mesma exposição radiante de 24J/cm. A resistência à flexão foi avaliada por meio do ensaio de flexão três pontos. Para este ensaio foram confeccionados trinta corpos de prova de cada material (n=10) com dimensões de 10mm x 2mm x 1mm. A avaliação da microdureza Knoop foi obtida a partir de seis discos de cada resina com 5mm de diâmetro por 2mm de espessura (n=2), sendo realizadas cinco indentações em cada espécime. Trinta corpos de prova cílindricos de cada compósito (n=10) com 3mm de diâmetro por 6mm de altura foram confeccionados para a realização do teste de tração diametral. A análise estatística dos resultados obtidos foi realizada por meio do teste de análise de variância (ANOVA) e do teste de múltiplas comparações de Tukey (p < 0.05). A resistência à flexão da resina P90 não foi influenciada de forma significativa pelas diferentes formas de ativação, enquanto a Z250 obteve resultados significantemente maiores para o protocolo de alta intensidade em relação ao convencional. Em todas as intensidades de luz, os resultados da Z250 foram significativamente maiores que os da P90. A microdureza da resina P90 foi estatisticamente maior para o grupo de média intensidade em relação aos outros, já a Z250 não obteve resultados com diferença estatística em relação às formas de ativação. Para a mesma irradiância, a Z250 obteve maiores valores de microdureza do que a P90, com exceção para o protocolo de média intensidade em que não houve diferença estatística entre os materiais. Os valores de resistência à tração não foram influenciados de forma significativa nem pelas diferentes intensidades de luz, nem pelos materiais utilizados. A influência da variação da intensidade de luz depende do tipo de compósito utilizado e da propriedade mecânica avaliada. / This study has the purpose of evaluating the variation of the intensity of light, for a constant radiation exposure, for flexural strength, for microhardness, and for tensile strength, of a conventional composite and a low shrinkage composite. The test samples were made of Filtek Z250 (3M ESPE) e Filtek P90 LS (3M ESPE) light-activated composites. The following light activating protocol was used: conventional (400mW/cm for 60 s); medium intensity (700mW/cm for 34 s), and high intensity (950mW/cm for 26 s). All of the test samples received the same radiation exposure of 24J/cm. The flexural strength was measured through the three-point bending test. For this test, thirty especimens were made for each material (n=10), measuring 10mm x 2mm x 1mm. The Knoop hardness evaluation was carried out using six discs of each composite measuring 5mm in diameter, and 2mm in height (n=2), with five indentations in each specimen. Thirty cylindrical test samples of each composite (n=10) measuring 3mm in diameter, and 6mm in height were obtained for the diametral tensile test. The statistical analysis of the results was carried out through analysis of variance test (ANOVA) and through Tukeys multiple comparisons test (p < 0.05). The P90 composite flexural strength was not significantly influenced by the different activating methods, while Z250 achieved significantly higher values for the high intensity protocol when compared to the conventional one. For all light intensities, the Z250 results were higher than those for P90. P90's microhardness was statistically higher for the medium intensity group when compared to the others, whereas Z250's results had no statistical difference for the different activating protocols. For the same irradiation, Z250 presented higher values for microhardness than P90, except for the medium intensity protocol, which had no statistical difference between the different materials. The tensile strength values were not significantly influenced neither by the different light intensities, nor by the materials. The influence of the variation of light intensity depends upon the type of composite, as well as the mechanical property to be evaluated.
132

Estudo do grau de conversão e dureza em compósitos odontológicos fotopolimerizáveis

Menegazzo, Lívia Maluf [UNESP] 22 May 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-05-22Bitstream added on 2014-06-13T19:12:25Z : No. of bitstreams: 1 menegazzo_lm_me_ilha.pdf: 652340 bytes, checksum: 7cd3c65c7db0577bbe66236ac50269ff (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho propõe o estudo do grau de conversão e de dureza de três resinas fotoativadas Fill Magic, TPH Spectrum e Te-Econom, em função do tempo de exposição e do tipo de fonte de luz. Foram utilizadas quatro fontes diferentes, sendo duas halógenas e duas baseadas em LED. O grau de conversão foi avaliado de espectros de absorção no infravermelho próximo e a dureza através de testes Vickers. Cinco amostras de 10 mm de diâmetro e 2 mm de espessura foram preparadas para cada tempo de exposição e tipo de fonte. Após exposição à luz, todas as amostras foram mantidas durante 7 dias em ambiente escuro antes de serem utilizadas para obtenção de espectros e serem submetidas ao teste de dureza. Os espectros foram obtidos em um espectrômetro Nexus 670 da Nicolet e a microdureza Vickers foi obtida com um microdurômetro HMV - 2T da Shimadzu. Os resultados mostraram que o grau de conversão aumenta com o tempo de exposição para fontes com densidade de potência menor que 233 mW/cm2. Não foi observada diferença significativa no grau de conversão nas amostras irradiadas com fontes halógena e LED, ambas com densidade de potência maior que 233 mW/cm2. Não foi possível estabelecer uma relação entre dureza e o tempo de exposição ou a densidade de potência. Entre as resinas, a FM é a que apresentou melhores valores de grau de conversão e a Te-Econom de dureza. / The aim of this study was to evaluate the degree of conversion and hardness of three photo-activated composites (Fill Magic, TPH Spectrum and Te-Econom) as a function of exposure time and type of light source. As visible light source were utilized four different units, two halogen and two light-emitting diodes (LED). The conversion degree was evaluated by near-infrared spectroscopy and the hardness by Vickers tests. Five samples of 10 mm diameter and 2 mm thickness were prepared for each exposure time and light source. The spectra were obtained in a Nexus 670 Nicolet spectrometer and the hardness in a HMV - 2T micro hardness tester (Shimadzu). These measurements were performed after 7 days dark storage. The results showed that the degree of conversion increases with the exposure time for the light units with power density smaller than 233 mW/cm2. No significant differences were observed in degree of conversion in samples irradiated with halogen and LED units, both with power density larger than 233 mW/cm2. There is not correlation between the conversion degree and the micro hardness for all studied composites. The highest values for conversion degree and hardness were obtained with the Fill Magic and Te-Econom composites, respectively.
133

Avaliação por microdureza Vickers da profundidade de polimerização de cimentos resinosos na cimentação de pinos de fibra de vidro empregando diferentes fontes de luz

Conti, Elaine Cristina Guerbach [UNESP] January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2006Bitstream added on 2014-06-13T20:41:44Z : No. of bitstreams: 1 conti_ecg_dr_arafo.pdf: 812838 bytes, checksum: c0f89cff921f9b0a2343ffde10308ae3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo foi avaliar a microdureza Vickers de um cimento resinoso químico (C&B Cement - Bisco) e um de ativação dual (RelyX ARC - 3M ESPE), fotopolimerizado por diferentes fontes de luz, em função de diferentes profundidades do canal radicular, na cimentação de pinos de fibra de vidro. Os aparelhos fotopolimerizadores empregados foram: Optilux 360 (Demetron) - luz halógena; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. Nenhuma diferença estatisticamente significante foi observada nos valores de microdureza Vickers, dos terços cervical, médio e apical do canal radicular, para o cimento resinoso químico (G1), e os terços cervicais do cimento resinoso dual, para todos os aparelhos fotopolimerizadores (G2, G3 e G4) (p>0.05). Porém, o aparelho de luz halógena (G2) e o LED UltraLume 5 (G4) apresentaram comportamentos semelhantes, proporcionando uma diminuição gradativa nos valores médios de microdureza do cimento resinoso dual, do terço cervical para o apical (p<0.001). Os menores valores de microdureza foram encontrados nos terços apical do sistema RelyX ARC fotopolimerizado com luz halógena ou com LED UltraLume 5. / This study evaluated the Vickers microhardness of a chemically cured resin cement (C&B Cement - Bisco) and a dual cure cement (RelyX ARC - 3M ESPE), light cured by different light sources, according to the different root canal depths, for luting of glass fiber posts. The light curing units employed were Optilux 360 (Demetron) - halogen lamp; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. No statistically significant difference was observed in Vickers microhardness values at the cervical, middle and apical root thirds for the chemically cured resin cement (G1), and at the cervical third for the dual resin cement, for all light curing units (G2, G3 and G4) (p>0.05). However, the halogen lamp unit (G2) and LED UltraLume 5 (G4) presented similar performance, providing gradual reduction in mean microhardness values for the dual resin cement from the cervical to the apical third (p<0.001). The lowest microhardness values were found at the apical third for the system RelyX ARC light cured with halogen lamp or LED UltraLume 5.
134

Avaliação da dureza superficial de cimentos resinosos após cimentação de pinos de fibra de vidro: efeito de profundidade de polimerização e sistemas adesivos

Jardim, Patrícia dos Santos [UNESP] 06 April 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-04-06Bitstream added on 2014-06-13T19:01:42Z : No. of bitstreams: 1 jardim_ps_dr_arafo.pdf: 1044832 bytes, checksum: e4dd0c96ad60802f6b6357bc3b691056 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os pinos pré-fabricados de fibra de vidro têm sido o sistema de escolha para reconstrução de dentes anteriores tratados endodonticamente e o sucesso da cimentação dos pinos de fibra de vidro está associado à cimentação do tipo adesiva, sendo que o agente cimente normalmente utilizado é um cimento resinoso de dupla polimerização, entretanto questiona-se a eficácia dos cimentos de dupla polimerização, principalmente nas regiões muito distantes da fonte de luz, bem como sua compatibilidade química com sistemas adesivos simplificados. O presente trabalho teve como objetivo avaliar a dureza superficial de cimentos resinosos, um quimicamente ativado (Bistite II DC) e um de dupla polimerização (Rely X) em função de diferentes profundidades de polimerização e sistemas adesivos; bem como, formação de camada híbrida quando da cimentação de pino de fibra de vidro no canal radicular de dentes bovinos. Foram utilizados 40 raízes bovinas, as quais foram tratadas endodonticamente e divididas aleatoriamente em 4 grupos de 10 raízes cada de acordo com o cimento resinoso e sistema adesivo utilizado para cimentação do pino de fibra de fivro: (GI) Bistite II DC; (GII) Rely X associado ao Scotchbond Multi-Uso Plus; (GIII) Rely X associado ao Single Bond; (GIV) Rely X associado ao One-Up Bond F. Após 24 horas da cimentação, as raízes foram seccionadas no sentido transversal em três discos radiculares, representando os terços cervical, médio e radicular, com profundidades respectivas de 3,0mm; 6,0mm e 9,0mm. Para realização das medidas de dureza, cada secção radicular foi dividida em quadrantes, nos quais foram realizadas três medidas: (M1) próximo à dentina radicular; (M2) região intermediária; (M3), próximo ao pino de fibra de vidro, cujos resultados foram submetidos à Análise de Variância e Teste de Tukey. Após o Ensaio de Dureza, as amostras foram... . / Fiber posts have been the system of choice for endodontically-treated anterior teeth reconstruction, and the cementation luting success is associated to adhesive-type cementation, being the dual-cure resin cements the most utilized cement. However, the dual-cured cements efficacy is questioned, mainly in the regions distant from the light-cure source, as well as the chemical compatibility to simplified adhesive systems. The aim of the present study was evaluate superficial roughness of resin cements, being one of them chemically activated (Bistite II DC) and the other dual-cured resin cement (Rely X) under different light-cure depths and bond systems; as well as hybrid layer formation in cases of glass fiber post in bovine radicular canal. Forty bovine roots samples were used. These roots were endodontically treated and randomly separated in four groups of 10 roots each according to the resin cement and adhesive system used for glass fiber post cementation.: The groups were divided as follows: (GI) Bistite II DC; (GII) Rely X associated to Scotchbond Multi-Purpose Plus; (GIII) Rely X associated to Single Bond; (GIV) Rely X associated to One-Up Bond F. After 24 hours passed from cementation, roots were sectioned in transversal orientation in three radicular discs, representing the cervical, medium and radicular thirds, with respective depths of 3,0mm; 6,0mm e 9,0mm. For hardness measuring, each radicular section was divided in quadrants. These quadrants were measured three times: (M1) near radicular dentin; (M2) intermediary region; (M3), near glass fiber post. These results were submitted to ANOVA and Tukey Test. After hardness assay samples were submitted to hybrid layer evaluation in Scanning Electron Microscopy and subsequent photomicrography descriptive analysis. From the methodology and... (Complete abstract, click electronic address below).
135

Modelo in situ de remineralização para determinar dose-resposta com dentifrícios de baixa concentração de fluoreto utilizando esmalte bovino

Oliveira, Rebeca Afonso Devides [UNESP] 10 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-10Bitstream added on 2014-06-13T20:04:52Z : No. of bitstreams: 1 oliveira_rad_dr_araca.pdf: 586147 bytes, checksum: 88772037412e98c9b238164e8322509e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Estudos realizados em diferentes países apontam o uso de dentifrícios fluoretados como o principal responsável pelo declínio na prevalência da cárie bem como pelo aumento na incidência da fluorose dentária. Um dos recursos para a promoção da saúde bucal e reparo das lesões cariosas, sem causar danos aos indivíduos, seria a diminuição da concentração de fluoreto no dentifrício mantendo a efetividade anticariogênica comparável a de um dentifrício padrão de mercado (1100 mg F/g) em situações de baixa ou alta atividade de cárie. O objetivo do presente estudo foi avaliar um modelo in situ de remineralização para determinar dose-resposta com dentifrícios de baixa concentração de fluoreto. O estudo foi duplo-cego linear, divido em 8 oito períodos experimentais com intervalos de 7 dias. Participaram da pesquisa 10 voluntários que utilizaram dispositivos palatinos contendo blocos de esmalte bovino desmineralizados. Foram estabelecidos dois regimes experimentais de 3 e 7 dias e 4 tratamentos com dentifrícios: placebo, 275, 550 e 1100 μg F/g. Foi realizada a análise da profundidade da desmineralização e decorridos os tempos experimentais realizaram-se as análises: de dureza (Knoop) de superfície e em secção longitudinal e da concentração de fluoreto presente no esmalte (μg F/mm3). Os dados apresentaram-se homogêneos e foram submetidos à análise de variância (p<0,05). A desmineralização apresentou uma profundidade média de 47,7 μm com característica de lesão de subsuperfície. As análises de dureza mostraram aumento na remineralização com o aumento da concentração de fluoreto nos dentifrícios com o regime experimental de 3 dias (p<0,05). O aumento no tempo de permanência na cavidade bucal e exposição aos dentifrícios fluoretados não aumentaram a concentração de fluoreto presente no esmalte para um mesmo dentifrício fluoretado (p>0,05)... / Studies developed in different countries indicate F dentifrices as the main reason for the decrease in caries prevalence as well as for the increase of dental fluorosis. One of the resources for oral health promotion and repair of carious lesions, with no damage to individuals, would be the reduction of F concentration in dentifrice with preservation of the anti-caries effect similar to a Gold Standard dentifrice (1100 mg F/g), during conditions of low or high caries activity. The aim of this study was to evaluate an in situ remineralization model for dose-response establishment using low fluoride concentration dentifrices. This randomized controlled double-blind study was performed according to the volunteers’ availability and had 8 experimental periods with 7-day intervals. The volunteers (n=10) wore palatal appliances containing demineralized bovine enamel blocks. Two experimental regimens (3 and 7 days) and dentifrices treatments (placebo, 275, 550 and 1100 μg F/g) were set. Demineralization depth using polarized light microscopy, surface and cross-sectioned hardness (Knoop) and F concentration in enamel (μg F/mm3) were determined. Data were homogeneous and submitted to analysis of variance (p<0.05). Demineralization areas presented a mean depth of 47.7 μm with traits of subsurface lesion. Hardness analysis showed a remineralization improvement as F concentration in dentifrices increased, for the 3-day experimental regimen (p<0.05). The augment of time in the oral cavity and of exposure to F dentifrices did not increase F concentration in enamel, considering similar F dentifrices (p>0.05). In addition, the dentifrice with 550 μg F/g (7 days) showed similar results of remineralization (p>0.05) when compared to dentifrices with 1100 μg F/g (3 and 7 days). It may be concluded that the in situ remineralization model showed the ability to verify dose-response with a 3-day... (Complete abstract click electronic access below)
136

Efeito do sulfato ferroso na desmineralização e remineralização do esmalte bovino: estudos in vitro e in situ

Alves, Karina Mirela Ribeiro Pinto [UNESP] 01 September 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-09-01Bitstream added on 2014-06-13T19:03:56Z : No. of bitstreams: 1 alves_kmrp_dr_araca.pdf: 700065 bytes, checksum: b8299b415de0444050114c036fd80725 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho avaliou o efeito do ferro (Fe) na desmineralização e remineralização de esmalte bovino e pó de hidroxiapatita sintetizada, em estudos in vitro e in situ. Avaliou-se o efeito de diferentes concentrações de Fe (0,33; 0,840; 18,0 e 70,0 μg Fe/mL), na forma de sulfato ferroso, em 3 capítulos distintos: na desmineralização e remineralização do esmalte bovino, usando modelos de ciclagem de pH (capítulo 1); na remineralização de lesões de cárie artificial em esmalte bovino in situ (capítulo 2); e na ciclagem de pH utilizando hidroxiapatita sintetizada (capítulo 3). No primeiro e segundo capítulos, blocos de esmalte tratados com Fe foram avaliados por meio de análise da microdureza de superfície e longitudinal. As análises de F, Ca, P e Fe presentes no esmalte foram determinadas após desmineralização (in vitro) e remineralização (in vitro e in situ). No terceiro capítulo, a análise da hidroxiapatita tratada com soluções de Fe e F foi realizada por meio de espectroscopia no infravermelho transformada de Fourier, além de análises de F, Ca, P e Fe nas soluções de ciclagem de pH. Houve redução da desmineralização do esmalte quando este foi tratado com 18,0 μg Fe/mL(p<0,05); embora, o grupo controle tenha apresentado maior recuperação da dureza na lesão de cárie quando comparado aos grupos tratados com Fe (p<0,05) in vitro. No estudo in situ, nenhuma concentração de Fe promoveu remineralização da lesão de cárie quando comparada ao grupo controle (p<0,05). Um aumento nas concentrações de Fe no esmalte foi observado quando maiores concentrações (18,0 e 70,0 μg Fe/mL) foram utilizadas in vitro e in situ (p<0,05). A taxa Ca/P diminuiu com a presença do Fe na hidroxiapatita (p<0,05) e um aumento do carbonato foi observado na presença... / The present study evaluated the effect of iron (Fe) on enamel demineralization and remineralization of bovine enamel and synthesized hydroxiapatite, using in vitro e in situ models. Different concentrations of Fe, as ferrous sulphate (0.33; 0.840; 18.0 and 70.0 μg Fe/mL) were evaluated in 3 distinct chapters: in bovine enamel demineralization and remineralization, using pH-cycling models (chapter 1); in remineralization of artificial caries lesions on bovine enamel in situ (chapter 2); and in pH cycling using synthesized hydroxiapatite (chapter 3). In the first and second chapters, enamel blocks treated with Fe were evaluated by superficial and longitudinal microhardness. The concentrations of F, Ca, P and Fe present in enamel were also determined after demineralization (in vitro) and remineralization (in vitro and in situ). In the third chapter, the analysis of hydroxyapatite treated with solutions of Fe and F were performed by Fourier Transform Infrared Spectroscopy, ian addition to the analysis of F, Ca, P and Fe in pH cycling solutions. A reduction on enamel demineralization was observed after treatment with 18.0 μg Fe/mL (p<0.05), although the control group presented the greatest recovery of the hardness of caries lesions when compared to groups treated with Fe in vitro (p<0.05). In the in situ study, none of the concentrations evaluated promoted remineralization of caries lesions when compared to the control group (p<0.05). Increases in Fe concentrations in enamel were observed when higher concentrations (18.0 and 70.0 μg Fe/mL) were used in vitro and in situ (p<0.05). The Ca/P rate decreased in the presence of Fe in hydroxyapatite (p<0.05) and an increase of carbonate was observed in the presence of different concentrations of Fe (p<0.05). It was concluded that treatment with a Fecontaining solution... (Complete abstract click electronic access below)
137

Influência de soluções fluoretadas na estabilidade de cor, rugosidade e dureza superficial de resinas compostas em função do tempo

Oliveira, Ana Luísa Botta Martins de [UNESP] 27 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-27Bitstream added on 2014-06-13T20:04:53Z : No. of bitstreams: 1 oliveira_albm_dr_arafo.pdf: 1363942 bytes, checksum: 31b5ccd566c55e1abf5a60c112fc13be (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a influência de soluções fluoretadas sobre a estabilidade de cor, a rugosidade e a dureza superficiais de diferentes resinas compostas, em curto e em longo prazo. Para isso, foram realizadas pesquisas científicas, apresentadas em três capítulos. Setenta e cinco espécimes de 10 mm de diâmetro e 2 mm de espessura foram confeccionados e polidos com discos de óxido de alumínio (Super-Snap®, Shofu Dental Corp. Kyoto, Japão) em ordem decrescente de granulação. Os grupos experimentais foram divididos de acordo com o tipo de resina composta (nanoparticulada - Filtek Z350 XT, microhíbrida - Filtek Z250 e microparticulada - Durafill VS) e diferentes meios de imersão (saliva artificial, solução de fluoreto de sódio a 0,05%- manipulado, Fluordent Reach, Oral B, Fluorgard). Os espécimes permaneceram imersos em saliva artificial por 24 horas e foram submetidos à análise da cor, rugosidade e dureza iniciais. A partir disso, foram imersos nas diferentes soluções por 1 minuto ao dia durante 60 dias. Nos intervalos entre as imersões foram mantidos em saliva artificial a 370C  1 0C. Após esse período, foram submetidos às novas avaliações de cor, rugosidade e dureza superficiais. Em sequência, foram realizados os procedimentos de envelhecimento artificial utilizando-se 20.000 ciclos de termociclagem, 1.200.000 ciclos de simulação de forças mastigatórias e imersão contínua nas soluções por 1825 minutos. Após estes processos, foram realizadas leituras finais para todas as propriedades avaliadas. Os dados obtidos, nos diferentes tempos, foram avaliados estatisticamente pela Análise de Variância. Para a estabilidade de cor, utilizou-se o teste de Tukey e para a rugosidade e a dureza superficiais, os testes de Tukey e de Sidak... / The aim of this study was to evaluate the influence of fluoride solutions on color stability, surface roughness and hardness of different composite resins, in short and long term. Seventy-five specimens of 10mm diameter and 2mm thickness were made with composite resins and polished with aluminum oxide discs (Super-Snap®, Shofu Dental Corp. Kyoto, Japan) in a decreasing order of granulation. Experimental groups were divided according to (1) composite resin (nanofilled- Filtek Z350 XT, mycrohybrid Filtek Z250 and microfilled - Durafill VS) and (2) different immersion media (artificial saliva, a manipulated 0.05% sodium fluoride solution, Fluordent Reach, Oral B, Fluorgard). Specimens were kept in artificial saliva for 24 hours and submitted to color, roughness and hardness tests. From this period, specimens were immersed in the different solutions for 1 minute per day, during 60 days. In periods between immersions, specimens were kept in artificial saliva at 370C  10C. After that, the specimens were submitted to color, roughness and hardness analysis again. Then the artificial aging was carried out using 20,000 thermal cycles, 1,200,000 mechanical loading cycles and continuous immersion in the solutions for 1825 minutes. After the artificial aging, specimens were submitted to color stability, roughness and hardness tests. The obtained data for different periods were submitted to ANOVA. The color change data were evaluated by Tukey test. Surface roughness and hardness data were submitted to Tukey and Sidak tests, both at 5% significance. The highest color change and surface roughness were observed with the microfilled composite resin, followed by the nanofilled and microhybrid resin. Besides that, the lowest hardness also was obtained with the microfilled resin. The artificial aging promoted an increase of roughness and... (Complete abstract click electronic access below)
138

Avaliação da qualidade óssea no reparo de defeitos ósseos sob a ação do risedronato e da deficiência estrogênica

Senra, Giselle Segnini [UNESP] 24 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-24Bitstream added on 2014-06-13T19:44:11Z : No. of bitstreams: 1 senra_gs_dr_sjc.pdf: 2645551 bytes, checksum: ee01850aed262e3ecbee732d745d1025 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O aumento da expectativa de vida amplia as possibilidades de doenças como a osteoporose, que elevam a ocorrência de fraturas e demandam longo tratamento. Nos últimos anos, muita atenção tem sido dada aos efeitos potenciais dos medicamentos para a osteoporose na reparação de fraturas advindas desta doença. O objetivo deste trabalho foi avaliar o efeito do Risedronato (10,5 mg/kg/semana) na qualidade óssea do reparo ósseo em ratas com deficiência estrogênica. Para isso, 84 ratas foram submetidas à ovariectomia e 42 ratas à cirurgia sham. Após 35 dias, lesões de 2,5 mm foram realizadas nos fêmures quando, então, se iniciou a medicação. Os animais ovariectomizados foram divididos em dois grupos, um recebendo risedronato e o outro recebendo água filtrada como placebo. Os animais foram sacrificados com 18, 45 e noventa dias de reparo. Cortes centrais dos defeitos de metade das ratas receberam análise morfológica ao MEV, teste de microdureza Vicker’s e através do μED-XRF foi realizado mapeamento, micro-análise semi-quantitativa do Ca e P do mineral ósseo e relação Ca/P. A outra metade dos animais, com o fêmur esquerdo operado (O) e o direito não-operado (NO), teve esses ossos congelados até a realização de ensaio de flexão em três pontos gerando valores de força máxima, rigidez e energia da força máxima. Para a análise estatística foram utilizados os testes: t-Student, Análise de Variância ANOVA, Comparação Múltipla de Tukey e Correlação Linear, todos com nível de significância de 5%. A microdureza (HV) se mostrou fortemente relacionada com as concentrações de Ca e de P, e moderadamente correlacionada com Ca/P. A ovariectomia não afetou os valores de microdureza e módulo de elasticidade (E), mas diminuiu a concentração de Ca, de P e a relação Ca/P aos 18 dias. O tratamento com risedronato aumentou os valores de HV e E, mas não interferiu... / The increase in life expectancy is associated with a higher osteoporosis incidence, which elevates the occurrence of bone fractures, and demand long treatment. In the last years, it’s increasing de interest in the potential effects of osteoporosis medication on bone fractures healing. The aim of this work will be to evaluate the effects of Risedronate (10,5 mg/Kg/week) on bone quality in the femoral callus in rats with induced osteopenia. For that, 84 rats were subject to ovariectomy, and 42 were sham operated. After 35 days, 2,5 mm monocortical bone lesions were drilled on all animals femurs. Then, treatment began. The ovariectomized animals, divided in two groups, received Risedronate or drinking water as a placebo. The animals were sacrificed at 18, 45 and ninety days of bone repair. The central sections from bone defects from half of the rats were analyzed to determine their morphology using an SEM, electron probe microanalysis (μED-XRF) from bone mineral Ca, P and Ca/P ratio and Vicker’s microhardness. Another half of the animals had the left femur operated (O), and the right one, non operated (NO), both frozen till be tested in threepoint flexure to derive maximum load, stiffness and energy absorbed to maximum load. Statistical analyses were performed using t-Student, ANOVA, Tukey and Linear Correlation tests, considering 5% significance. Microhardness was strongly correlated to Ca and P concentrations but it was moderately correlated with Ca/P. Ovariectomy didn’t affect microhardness (HV) and Young modulus (E) but diminished, at 18 days, Ca/P, Ca and P concentrations. Risedronate treatment achieved increasing in HV and E without interference on Ca/P, Ca and P concentration of bone callus. Ovariectomy and healing time almost didn’t have influence on biomechanical properties of O, different from risedronate, which diminished these properties at 18 and 45 days. The HV and E from... (Complete abstract click electronic access below)
139

Influência da adição de nanopartículas sobre a dureza, resistência à ruptura e deformação permanente de silicone facial submetido ao envelhecimento acelerado

Nobrega, Adhara Smith [UNESP] 20 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-20Bitstream added on 2015-03-03T12:06:36Z : No. of bitstreams: 1 000795003.pdf: 1118199 bytes, checksum: 98a54dea093e378451b9a2f7d2e032e2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Apesar de satisfatórias, as próteses maxilofaciais apresentam limitações quanto à estética, conforto e durabilidade. Por isso estudos com o objetivo de melhorar as propriedades desses materiais são incessantes. É comprovada a eficiência da adição de nanopartículas na proteção de silicones, evitando a degradação da sua cor, no entanto a literatura é escassa quando se refere a outras alterações das propriedades físicas causadas no silicone facial. Assim, o objetivo deste estudo é avaliar a influência da adição de nanopartículas na ruptura, deformação permanente e dureza do Silicone Facial Silastic MDX4-4210. Foram confeccionadas 560 amostras em silicone facial, sendo 280 dessas amostras para o teste de ruptura, 140 para o teste de dureza e 140 para o teste de deformação permanente. As nanopartículas adicionadas na confecção das amostras de silicone foram: óxido de zinco (ZnO); sulfato de bário (BaSO4) e dióxido de titânio (TiO2). Para cada teste (exceção do teste de ruptura, no qual a quantidade de amostras será confeccionada em duplicata), 40 amostras de silicone serão confeccionadas com adição de cada um dos tipos de nanopartículas, totalizando 120 amostras; 10 amostras de silicone com tinta a óleo, sem nanopartículas, e 10 amostras somente de silicone .Para cada tipo de nanopartícula adicionada ao silicone facial, 20 amostras foram confeccionadas na concentração de 1% e 20 na concentração de 2%. Para cada concentração de nanopartículas, metade (10 amostras) foi com adição de tinta a óleo e a outra metade sem tinta a óleo. As amostras foram submetidas aos ensaios de dureza, resistência à ruptura e deformação permanente, e 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Pode-se... / Although satisfactory, the maxillofacial prostheses present aesthetics, comfort and durability limitations. Therefore, studies with the purpose to obtain better properties of these materials are unceasing. The efficiency of adding nanoparticles to silicon protection is well proven in preventing its color degradation, however the literature is scarce when it comes to other physical property changes with infacial silicon.The aim of this study is to evaluate the influence of nanoparticles addition to hardness, rupture resistance and permanent deformation of Facial Silicone Silastic MDX4-4210. 560 samples of facial silicone were made, 280 for rupture resistance test, 140 for hardness test and 140 for permanent deformation test. Nanoparticles added in the preparation of silicone samples were zinc oxide (ZnO), barium sulfate (BaSO4) and titanium dioxide (TiO2). For each test (except the rupture test, in which the samples are duplicated), 40 samples will be made of silicon added to each type of nanoparticles, totaling 120 samples, 10 samples of silicone with oil paint without nanoparticles, and 10 samples only of silicone (control group). For each type of nanoparticle added to the facial silicone, 20 samples were prepared at a concentration of 1% and 20 at a concentration of 2%. For every concentration of nanoparticles, half (10 samples) were added oil paint and the other half without oil paint. Samples were submitted to testing hardness, rupture resistance and permanent deformation, and 1008 hours of accelerated aging. The data were subjected to statistical analysis using nested ANOVA and Tukey tests. It can be verified through the results that the presence of nanoparticles influenced the hardness, tear strength and permanent deformation of the assessed groups. We conclude that all evaluated nanoparticles influenced the hardness, tear strength and permanent... / FAPESP: 12/05270-3
140

Composição superficial e propriedades mecânicas e tribológicas de aços carbono implantados com nitrogênio

Santos, Carlos Alberto dos January 1984 (has links)
Investigam-se no presente trabalho as relações entre a composição superficial e as propriedades mecânicas e tribolõgicas de aços carbono implantados com nitrogenio. Os resultados dos testes de propriedades mecanicas e tribolõgicas foram extraídos da literatura. A análise da composição su perficial fdi realizada através da espectroscopia Wissbauer de elétrons de conversão (CEMS) e de raios-X de conversão (CXMS). Recozimentos em alto vácuo foram realizados para simular o aumento de temperatura nos processos tribolõgicos reais. Os resultados obtidos mostram que hã uma tendência para pre cipitação de carbonitretos de ferro, finamente distribuídos, em aços carbono implantados com nitrogénio. A quantidade de carbono pré-existente desempenha um papel relevante nessa tendência. Mostra-se que a melhoria das propriedades mecânicas e tribo lOgicas de aços carbono implantados com nitrogenio e fundamentalmente devida ao mecanismo de endurecimento por precipitação. Mostra- se também que a persistencia do efeito protetor em profundida des muito maiores do que a camada implantada, está associada com a difusão do nitrogenio liberado pela decomposição térmica dos com postos superficiais. / The relationships between the surface composition and the mechanical and tribological properties of carbon steels implanted with nitrogen were investigated. The results from the mechanical and tribological tests were extracted from the literature. The surface composition analysis was. performed with the conversion electron and X-ray Mdssbauer spectroscopy (CENS and CXMS). Thermal annealing was performed in high vacuum, in order to simulate the temperature increase in real tribological processes. The obtained results shown the tendency to iron carbonitrides precipitation, finely dispersed, induced by nitrogen implantation into carbon steels. The amount of carbon pre-existent plays a relevant rõle in this trend. It is shown that the improved mechanical and tribological performance of nitrogen-implanted carbon steels are mainly due to the precipitation hardening mechanism. It is shown also that the persistence of the protective action at greater depths is associated with the in-diffusion of nitrogen released by thermal decomposition of the compounds formed at the surface.

Page generated in 0.0424 seconds