• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 334
  • 16
  • 9
  • 9
  • 9
  • 9
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 359
  • 248
  • 94
  • 80
  • 69
  • 56
  • 54
  • 54
  • 51
  • 51
  • 50
  • 44
  • 43
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação do comportamento mecânico de um adesivo estrutural epóxi utilizado na indústria automobilística. / Evaluation of the mechanical behavior of a structural epoxy adhesive used in the atomobilistic industry.

Santos, Alessandra Fernandes 05 August 2005 (has links)
Na indústria automobilística há uma grande preocupação em relação ao custo e ao peso das peças utilizadas em projetos e os adesivos vem sendo utilizados para substituir a solda ponto com esta finalidade. Neste contexto o adesivo epóxi estrutural Betamate 1496 vem sendo empregado pela Volkswagen do Brasil S.A para substituição de solda a ponto na fabricação da porta dianteira do veículo Pólo Hatch. O adesivo Betamate 1496 é utilizado na fabricação da carroçaria do veículo Pólo Hatch da Volkswagen do Brasil SA com essa finalidade. O objetivo do presente trabalho é propor e testar uma metodologia para avaliar o estado de cura do adesivo epóxi Betamate 1496 por meio da determinação do seu módulo de elasticidade e de sua dureza, quando este é empregado na fabricação das portas dianteiras do veículo Pólo Hatch. Estas propriedades foram determinadas pela medição das propriedades mecânicas do adesivo em amostras retiradas em seis posições da porta em duas fases de processamento: estado pré-curado, durante a montagem da porta e estado curado, após a cura final na estufa de pintura. O estudo foi realizado através do ensaio de indentação instrumentada, utilizando os procedimentos experimentais propostos por Franco Jr. e colaboradores e Pintaúde e colaboradores na avaliação das propriedades do polímero. O estado de cura do polímero foi avaliado de modo qualitativo também pela técnica de calorimetria diferencial exploratória (Differential Scanning Calormetry). Os resultados obtidos pela metodologia proposta por Franco Jr. e colaboradores apresentaram grande dispersão de valores, provavelmente pelo fato do método propagar erros de arredondamento na aplicação do algoritmo. Conforme observado nos resultados experimentais obtidos pela metodologia proposta por Pintaúde e colaboradores, no estado pré-curado todas as amostras apresentam valores de módulo de elasticidade muito próximos, em torno de 1,0 + 0,1. GPa, independentemente da posição na porta ou do tempo de descarregamento, já no estado curado observa-se uma diferença significativa dos valores de módulo de elasticidade, E, e dureza H dependendo da posição original da amostra na porta, com as amostras retiradas das posições inferiores apresentando E=0,8 + 0,1 GPa, enquanto que as demais apresentam E=1,0+0,1 GPa, os valores de dureza, H, para todas as amostras curadas foi H=0,03 GPa. A analise qualitativa do ensaio térmico pelas as curvas obtidas no ensaio térmico de DSC mostra que as curvas da amostra no estado pré-curado e curado são idênticas, indicando o ciclo de cura do polímero já se completa na fase de montagem da porta, antes mesmo da cura final na estufa de pintura. / Cost and weight reduction are major concerns of the automobilist industry, this leads to the increasing substitution of spot weld by adhesives in the assembling of automobile parts. In this context Volkswagen do Brazil S.A uses the Betamate 1496 structural epoxy adhesive in the manufacture of the chassis of the Polo v. Hatch. The aim of the present work is to suggest and to test a methodology to evaluate the state of cure of this adhesive by means of the determination of its hardness and elastic modulus when used in the manufacture of the front doors of the Polo v. Hatch vehicle. These properties have been determined by the measurement in six samples removed from different positions at the two phases of processing: after assembling of the chassis and cured state, after final cure at painting. The study was carried through instrumented indentation testing, which used the experimental procedures suggested by Franco Jr. and collaborators and Pintaúde and collaborators. The state of cure of polymer was evaluated also in qualitative way by Differential Scanning Calorimetry. The results obtained by the Franco Jr. methodology show great dispersion of values, probable due to the fact that the method propagates rounding errors in the application of the algorithm. The experimental results obtained by the Pintaúde methodology show that, in the state after assembling of the chassis all samples present elastic modulus, E, around 1,0 + 0.1 GPa, independently of the position in the door. In the cured state is observed depending on the sample’s position at the door: samples taken from the bottom of the door shaved E=0,8 + 0,1 GPa, while the remaining showed E= 1,0 + 0,8 GPa. The hardness, H, of the adhesive is constant (H=0,03 GPa) for all samples. The comparison of DSC curves obtained from the incurred and cured samples, showed that they are very similar, suggesting that the cure cycle of the polymer is already completed at assembling stage of the door.
112

Avaliação da maturação pós-eruptiva do esmalte de dentes humanos hígidos e sua resposta frente a um desafio cariogênico in vitro por meio da microdureza longitudinal / Assessment of maturity post-eruptive enamel of healthy enamel human teeth and its response against a in vitro cariogenic challenge through longitudinal microhardness

Sousa, Janaína Maniezo de 07 December 2010 (has links)
Sabe-se que dentes recém-irrompidos são mais susceptíveis a lesões cariosas comparados aos dentes mais velhos. O risco elevado à desmineralização tem sido também comprovado por experimentos in vitro. No entanto, a maioria dos trabalhos é realizada com amostras polidas provenientes de diferentes tipos de dentes. Adicionalmente, não há dados comparativos entre a mesma amostra hígida e desmineralizada. Portanto, este estudo teve como objetivo avaliar o impacto da maturação pós-eruptiva do esmalte humano hígido sobre a desmineralização in vitro por meio da microdureza longitudinal. Cada grupo de dentes foi composto por 12 espécimes de esmalte de terceiros molares: não irrompidos, com 1 a 6 meses de erupção e com 2 a 3 anos de erupção. As amostras foram protegidas em 2/3 da superfície e submetidas à formação de lesão cariosa artificial (gel de metilcelulose com ácido lático, pH 4,6, 14 dias). A microdureza longitudinal foi realizada na superfície hígida e desmineralizada nas distâncias de 10 a 220µm. Os dados foram analisados por ANOVA/Tukey ou Kruskall-Wallis/Dunn (p<0,05). As médias de dureza da superfície hígida (KHN), o KHN (superfície cariada) e a profundidade da lesão (m) para os grupos submetidos ao desafio cariogênico foram, respectivamente: incluso (333,2/13.567/81,67), 1-6m (355,9/13.332/78,33) e 2-3a (382,9/14.019/73,33). Concluiu-se que dentes com diferentes idades pós-eruptivas apresentam diferenças em relação à microdureza longitudinal do esmalte hígido que podem não refletir em maior susceptibilidade à desmineralização quando um gel acidificado é utilizado para provocar lesão de cárie artificial. / It is known that newly erupted teeth are more susceptible to carious lesions compared to older teeth. The high risk of demineralization has also been proven by in vitro experiments. However, most work is performed with polished samples from different types of teeth. Additionally, there is no comparative data between sound and demineralized enamel from the same tooth. Therefore, this in vitro study evaluated enamel maturation at different depths in sound and demineralized human teeth at different posteruptive ages by cross-sectional hardness (CSH). Each group was composed by 12 enamel samples from 3rd molars: unerupted, with 1-6 months and 2-3 years. The samples had two thirds of the surface protected and were subjected to demineralization (methylcellulose gel/lactic acid, pH 4.6, 14 days). Cross-sectional hardness was performed on sound and demineralized enamel on distances from 10 to 220µm. Data were analyzed by ANOVA/Tukey or Kruskall-Wallis/Dunn (p<0.05). Means of sound enamel hardness (KHN), KHN (demineralized surface) and lesion depth (m) for the groups submitted to acid gel were: unerupted (333.2/13,567/81.67), 1-6 m (355.9/13,332/78.33) and 2-3y (382.9/14,019/73.33). It was concluded that teeth with different post-eruptive ages differ regarding to the cross-sectional hardness of sound enamel, which in turn may not reflect a higher susceptibility to demineralization when an acidified gel is used to provoke artificial carious lesion.
113

Estudo da dureza e do grau de conversão de resinas compostas: efeito de fonte de luz e material

Ribeiro, Benícia Carolina Iaskieviscz [UNESP] 23 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-23Bitstream added on 2014-06-13T19:40:56Z : No. of bitstreams: 1 ribeiro_bci_dr_arafo.pdf: 5110465 bytes, checksum: 9456c5ff12e39d6e87024eccdba81454 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A evolução dos materiais odontológicos, a interação de resinas compostas e aparelhos fotopolimerizadores motivaram a realização deste estudo. Foram selecionadas quatro resinas compostas fotopolimerizáveis indicadas para restaurações diretas, sendo três microhíbridas: Vit-l-escenceTM (Ultradent®), Amelogen® Plus (Ultradent®) e Opallis (FGM) e outra de nanopartículas: FiltekTM Z350 (3M ESPE Dental Products), todas indicadas para dentina e na cor A2. Construiram-se corpos-de-prova com dimensões de 4 mm de diâmetro e 2 mm de profundidade (ISO 4049), os quais foram polimerizados por diferentes aparelhos fotoativadores. Para o primeiro estudo, utilizou-se o Led Ultra Lume Led 2 (Ultradent®) e uma luz halógena (Ultralux - Dabi Atlante), esta com diferentes ponteiras condutoras de luz. Decorridas 24 horas, os corpos-de-prova foram submetidos ao ensaio de dureza utilizando-se um aparelho MMTT-3 Microhardness Tester (Buehler Lake Bluff, Illinois USA), com o qual foram realizadas quatro aferições na superfície do topo da amostra (dureza 1) e mais quatro na superfície de base (dureza 2) oposta à fonte de luz. Para o segundo estudo, novos corpos-de-prova foram confeccionados da mesma maneira, utilizando-se a luz halógena (Ultralux Dabi Atlante) com ponteira de vidro, um LED de terceira geração (Ultra Lume Led 5 Ultradent®) e dois leds de segunda geração: Radii-Cal (SDI) e Elipar Free LightTM 2 da 3M ESPETM. Os corpos-deprova foram submetidos ao mesmo teste, em dois tempos: imediato e após 24 horas. Para a terceira pesquisa, pela qual se avaliou o grau de conversão por FT-IR, empregando-se o espectrofotômetro Nexus FT- IR, confeccionou-se do mesmo modo outros corpos-de-prova e, decorridas 24 horas, estes foram triturados e misturados com KBr para a obtenção de pastilhas. Como parâmetro, confeccionou-se mais 20 pastilhas com resinas não curadas... / Our study was motivated by the evolution of dental materials, and the interaction between composite resin and light curing units. We selected four light-curing composite resins suitable for direct restorations, in shade A2, three microhybrid (Vit-l-escenceTM - Ultradent®) (Amelogen® Plus - Ultradent ®) (Opallis - FGM) and one nanoparticles (FiltekTM Z350 - 3M ESPE Dental Products), all indicated for dentin. All specimens were built with dimensions of 4mm diameter and 2mm deep, (ISO 4049) which were irradiated by different light-curing units. For the first study, we used the Led Ultra Lume Led 2 (Ultradent®), and a halogen light (Ultralux - Dabi Atlante) with the last having different conductive tips of light. At 24 hours, samples were tested in microhardness through the device MMTT-3 Microhardness Tester (Buehler Lake Bluff, Illinois USA) where 4 measurements were performed in the top surface (hardness 1) and 4 more in the base area (hardness 2), opposite to the source of light. For the second study, new specimens were prepared in the same way, using the Light Halogen (Ultralux Dabi Atlante) with a glass pipette, a third-generation led (Ultra Lume Led 5 Ultradent®) and two second-generation LEDs: Radii-Cal (SDI) and Elipar Free LigthTM 2 (3M ESPETM). The samples were subjected to the same test in two stages: immediate and after 24 hours. For the third study, which evaluated the degree of conversion by FT-IR, using the spectrophotometer Nexus FT-IR, samples were built in the same manner and after 24 hours they were powdered and mixed with KBr, to obtain tablets. As a parameter, 20 more tablets were prepared with uncured resin. Data were collected and subjected to statistical analysis. In the first study, it was concluded that the led device (second generation) allowed polymerization and the resulting hardness values were equivalent to the halogen unit for three of the four... (Complete abstract click electronic access below)
114

Efeito da bioinspiração e infiltração de zircônia por sílica nas propriedades mecânicas de bicamadas cerâmicas / The effect of bioinspiration and zirconia infiltration with silica on mechanical properties of bilayered ceramics

Toyama, Dominique Yukie [UNESP] 30 January 2017 (has links)
Submitted by Dominique Yukie Toyama null (dominique.toyama@gmail.com) on 2017-03-05T17:10:56Z No. of bitstreams: 1 Dissertação Dominique Toyama v2.pdf: 2694471 bytes, checksum: 46622aaa3d27a2c4661becae14cbed29 (MD5) / Rejected by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: No campo “Versão a ser disponibilizada online imediatamente” foi informado que seria disponibilizado o texto completo porém no campo “Data para a disponibilização do texto completo” foi informado que o texto completo deverá ser disponibilizado apenas 6 meses após a defesa. Caso opte pela disponibilização do texto completo apenas 6 meses após a defesa selecione no campo “Versão a ser disponibilizada online imediatamente” a opção “Texto parcial”. Esta opção é utilizada caso você tenha planos de publicar seu trabalho em periódicos científicos ou em formato de livro, por exemplo e fará com que apenas as páginas pré-textuais, introdução, considerações e referências sejam disponibilizadas. Se optar por disponibilizar o texto completo de seu trabalho imediatamente selecione no campo “Data para a disponibilização do texto completo” a opção “Não se aplica (texto completo)”. Isso fará com que seu trabalho seja disponibilizado na íntegra no Repositório Institucional UNESP. Por favor, corrija esta informação realizando uma nova submissão. Agradecemos a compreensão. on 2017-03-09T14:01:43Z (GMT) / Submitted by Dominique Yukie Toyama null (dominique.toyama@gmail.com) on 2017-03-10T18:49:30Z No. of bitstreams: 1 Repositório.pdf: 9462693 bytes, checksum: b3c5b554b9ad7e33181206e7a901f8e6 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-03-16T19:50:08Z (GMT) No. of bitstreams: 1 toyama_dy_me_sjc.pdf: 9462693 bytes, checksum: b3c5b554b9ad7e33181206e7a901f8e6 (MD5) / Made available in DSpace on 2017-03-16T19:50:08Z (GMT). No. of bitstreams: 1 toyama_dy_me_sjc.pdf: 9462693 bytes, checksum: b3c5b554b9ad7e33181206e7a901f8e6 (MD5) Previous issue date: 2017-01-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho avaliou-se o comportamento mecânico e a homogeneidade estrutural de bilaminados cerâmicos com configuração convencional (compressão da zircônia) e bioinspirada (tração da zircônia) com e sem infiltração de sílica. Além disso, determinou-se a distribuição de tensões utilizando a análise de elementos finitos, e avaliou-se o modo de falha e o mecanismo de adesão da interface porcelana/zircônia. Amostras bilaminadas foram confeccionadas com Y-TZP e cerâmica injetável e divididos em 4 grupos (n=30): zircônia sob compressão (T), zircônia infiltrada sob compressão (I), zircônia sob tração (B) e zircônia infiltrada sob tração (BI); para teste da resistência à flexão biaxial. A infiltração por sílica ocorreu pelo método sol-gel. Os dados (MPa) do ensaio mecânico foram avaliados com análise de Weibull (IC 95 %). Análise de elementos finitos utilizou o critério de tensão máxima principal para avaliar a distribuição de tensões nos modelos e seus resultados foram apresentados em forma de figuras e gráficos da tensão máxima principal (TMP). A camada de infiltração foi caracterizada usando DRX e microscopia (MEV, MEV-FEG e EDS). O comportamento da interface foi analisado usando resistência ao risco e dureza. O grupo mais homogêneo estruturalmente foi o BI (m= 9,59). A concentração de tensão na cerâmica feldspática foi menor nos grupos bioinspirados. Houve formação de silicato de zircônia na superfície dos discos de zircônia infiltrados e preenchimento de defeitos superficiais e internos. A zircônia tradicional teve desempenho melhor do que a zircônia infiltrada no teste de resistência ao risco. A endentação interfacial mostrou que o elo mais fraco do conjunto é a cerâmica feldspática. Conclui-se que para melhorar o desempenho de bilaminados é preciso melhorar o material de recobrimento e não a adesão entre os materiais. / This study analyzed the mechanical behavior of bilayers using conventional arrangement (leucite ceramic under traction) and a bioinspired arrangement (zirconia under traction) with or without sol-gel silica infiltration, analyze stress distribution using FEA, characterize infiltration layer and observe interfacial behavior. 120 bilayered specimens were produced for biaxial flexural strength testing using Y-TZP and pressed ceramic and divided into 4 groups (n=30): zirconia under compression (T), infiltrated zirconia under compression (I), zirconia under traction (B) and infiltrated zirconia under traction (BI). The zirconia was infiltrated using sol-gel method. The results for the biaxial flexural strength (MPa) were analyzed using Weibull analysis (CI 95 %). Stress distribution within the models were examined using maximum principal stress and the results were presented as graphs and figures. The infiltration layer was characterized using XRD and microscopy (SEM, FEG-SEM and EDS). The interfacial behavior was analyzed using scratch test and micro-hardness indentation. The BI group was the most reliable (m=9.59). The stress distribution in the feldspar ceramic was better for the bioinspired groups. The infiltrated zirconia discs presented zirconia silicate formation on the surface and plugged internal flaws. The traditional zirconia had a better scratch performance compared to the infiltrated zirconia. The interfacial indentation showed that the weakest link of the set is the feldspar ceramic. To improve the performance of bilayers, a better coverage material is needed rather than an improvement in adhesion.
115

Avaliação da qualidade óssea no reparo de defeitos ósseos sob a ação do risedronato e da deficiência estrogênica /

Senra, Giselle Segnini. January 2009 (has links)
Orientador: Adriana Aigotti Haberbeck Brandão / Banca: Andressa Costa Pereira / Banca: Rosilene Fernandes da Rocha / Banca: Luana Marotta Reis de Vasconcellos / Banca: Victor Elias Arana-Chavez / Resumo: O aumento da expectativa de vida amplia as possibilidades de doenças como a osteoporose, que elevam a ocorrência de fraturas e demandam longo tratamento. Nos últimos anos, muita atenção tem sido dada aos efeitos potenciais dos medicamentos para a osteoporose na reparação de fraturas advindas desta doença. O objetivo deste trabalho foi avaliar o efeito do Risedronato (10,5 mg/kg/semana) na qualidade óssea do reparo ósseo em ratas com deficiência estrogênica. Para isso, 84 ratas foram submetidas à ovariectomia e 42 ratas à cirurgia sham. Após 35 dias, lesões de 2,5 mm foram realizadas nos fêmures quando, então, se iniciou a medicação. Os animais ovariectomizados foram divididos em dois grupos, um recebendo risedronato e o outro recebendo água filtrada como placebo. Os animais foram sacrificados com 18, 45 e noventa dias de reparo. Cortes centrais dos defeitos de metade das ratas receberam análise morfológica ao MEV, teste de microdureza Vicker's e através do μED-XRF foi realizado mapeamento, micro-análise semi-quantitativa do Ca e P do mineral ósseo e relação Ca/P. A outra metade dos animais, com o fêmur esquerdo operado (O) e o direito não-operado (NO), teve esses ossos congelados até a realização de ensaio de flexão em três pontos gerando valores de força máxima, rigidez e energia da força máxima. Para a análise estatística foram utilizados os testes: t-Student, Análise de Variância ANOVA, Comparação Múltipla de Tukey e Correlação Linear, todos com nível de significância de 5%. A microdureza (HV) se mostrou fortemente relacionada com as concentrações de Ca e de P, e moderadamente correlacionada com Ca/P. A ovariectomia não afetou os valores de microdureza e módulo de elasticidade (E), mas diminuiu a concentração de Ca, de P e a relação Ca/P aos 18 dias. O tratamento com risedronato aumentou os valores de HV e E, mas não interferiu... (Resumo completo clicar acesso eletrônico abaixo) / Abstract: The increase in life expectancy is associated with a higher osteoporosis incidence, which elevates the occurrence of bone fractures, and demand long treatment. In the last years, it's increasing de interest in the potential effects of osteoporosis medication on bone fractures healing. The aim of this work will be to evaluate the effects of Risedronate (10,5 mg/Kg/week) on bone quality in the femoral callus in rats with induced osteopenia. For that, 84 rats were subject to ovariectomy, and 42 were sham operated. After 35 days, 2,5 mm monocortical bone lesions were drilled on all animals femurs. Then, treatment began. The ovariectomized animals, divided in two groups, received Risedronate or drinking water as a placebo. The animals were sacrificed at 18, 45 and ninety days of bone repair. The central sections from bone defects from half of the rats were analyzed to determine their morphology using an SEM, electron probe microanalysis (μED-XRF) from bone mineral Ca, P and Ca/P ratio and Vicker's microhardness. Another half of the animals had the left femur operated (O), and the right one, non operated (NO), both frozen till be tested in threepoint flexure to derive maximum load, stiffness and energy absorbed to maximum load. Statistical analyses were performed using t-Student, ANOVA, Tukey and Linear Correlation tests, considering 5% significance. Microhardness was strongly correlated to Ca and P concentrations but it was moderately correlated with Ca/P. Ovariectomy didn't affect microhardness (HV) and Young modulus (E) but diminished, at 18 days, Ca/P, Ca and P concentrations. Risedronate treatment achieved increasing in HV and E without interference on Ca/P, Ca and P concentration of bone callus. Ovariectomy and healing time almost didn't have influence on biomechanical properties of O, different from risedronate, which diminished these properties at 18 and 45 days. The HV and E from... (Complete abstract click electronic access below) / Doutor
116

Efeito de um infiltrante resinoso no tratamento de lesões de mancha branca: análise in vitro e in situ / Efffect of a resinous infiltrant on the tratment of white spot lesions: in vitro and in situ analysis

Maria Cristina Carvalho de Almendra Freitas 10 April 2015 (has links)
Dentre as estratégias de tratamento de lesões incipientes de cárie, no estágio de mancha branca ativa, o infiltrante resinoso tem sido empregado, preenchendo os poros do esmalte e impedindo a sua progressão. O objetivo deste trabalho foi avaliar o efeito do infiltrante de cárie (Icon®) sobre lesões cariosas artificiais produzidas por diferentes protocolos e a eficiência deste tratamento após novo desafio ácido por modelos experimentais in vitro e in situ, utilizando a microdureza de superfície (MS) e longitudinal (ML). Na fase in vitro, lesões cariosas artificiais foram produzidas em 45 espécimes de esmalte bovino (6x4mm) através de três diferentes protocolos (ciclagem DES-RE, gel MC e solução MHDP). Os espécimes foram tratados com o infiltrante e submetidos a novo desafio ácido por ciclagem DES-RE. Este delineamento resultou em 4 condições em um mesmo espécime: hígida (H), após a desmineralização (D), após o tratamento com o infiltrante (I) e após o novo desafio ácido (N). Na fase in situ, 15 voluntários usaram dispositivos palatinos contendo dois espécimes por 14 dias, induzindo a lesão por meio de gotejamento de solução de sacarose 8x/dia. Nas duas fases, a MS e ML foram avaliadas em todas as condições dos espécimes até 220&#x3BC;m. Os dados foram coletados e processados pela porcentagem da diferença com os valores iniciais da condição hígida para serem analisados estatisticamente de acordo com ANOVA (medidas repetidas) e teste de Tukey (p<0,05). No estudo in vitro e in situ todos os protocolos de desmineralização foram capazes de produzir lesões de cárie de subsuperfície. Todos os protocolos in vitro promoveram perda de dureza de superfície maior que 75%, enquanto o protocolo in situ promoveu quase 40%. Há uma redução da perda de dureza à medida que a profundidade aumenta em todos os casos, sendo as particularidades mais observadas até 50 &#x3BC;m. O infiltrante avaliado em todas as condições foi capaz de re-equilibrar parcialmente a dureza interna, entretanto sua resistência e efeito após o novo desafio ácido apresentou-se limitado. / Among the strategies for early caries lesions treatment as active white spot, the resin infiltrant has been employed filling the enamel pores and preventing their progression. The aim of this study was to evaluate the effect of caries infiltrant (Icon®) on artificial carious lesions produced by different protocols, and the efficiency of this treatment after new challenge acid by in vitro and in situ experimental models, using the surface microhardness (SH) and cross-sectional microhardness (CSH). In the in vitro phase, artificial carious lesions were performed on 45 enamel bovine specimens (6x4mm) by three different protocols (DE-RE cycling, MC gel and MHDP solution). The specimens were treated with the infiltrant and subjected to a new challenge by DE-RE cycling. This design resulted in four conditions at the same specimen: sound (S), after demineralization (D), after the treatment with infiltrant (I) and after the new acid challenge (N). In the in situ phase, 15 volunteers wore intraoral appliances containing two specimens for 14 days, inducing the lesion formation by sucrose solution dripping 8x/day. In both models, SH and CSH were evaluated in all conditions of the specimens up to 220&#x3BC;m. Data were collected and processed as percentage from the difference to each condition compared to sound stage to be statistically analyzed with ANOVA (repeated measures) and Tukey test (p <0.05). For all tested conditions, demineralization protocols were able to produce subsurface carious lesions. All in vitro protocols promoted hardness loss higher than 75% while in situ protocol promoted almost 40%. There is a reduction in the hardness loss as the depth increases, in which the main differences can be noticed up to 50&#x3BC;m. The infiltrant evaluated in all conditions was able to partially re-balance the internal hardness, however its strength and effect after the new challenge acid had been limited.
117

Influência da profundidade e de um processo de envelhecimento acelerado em propriedades de resinas bulk fill / Influence of depth and an accelerated aging process on bulk fill resin properties

Pereira, Amanda Cavalcante 14 November 2017 (has links)
O presente estudo teve como objetivo avaliar o desempenho de quatro resinas bulk fill (Filtek Bulk Fill (FBF), Opus Bulk Fill (OBF), Sonicfill (SF) e Tetric N-Ceram Bulk Fill (TNBF)) e uma resina convencional (Charisma Diamond (CD)) quanto às seguintes propriedades: resistência à flexão (RF), módulo de elasticidade (ME) e dureza Knoop (KHN) em função da profundidade e após a realização de um envelhecimento acelerado. Corpos de prova em formato de barra foram confeccionados simultaneamente em diferentes profundidades (1, 2, 3, 4 e 5 mm) para realização dos testes de resistência à flexão (n=10), módulo de elasticidade (n=10) e dureza Knoop (n=3). Os testes foram realizados em dois momentos, previamente e após a realização de um envelhecimento acelerado, que consistiu na realização de uma termociclagem com banhos alternados em água a 5 e 55ºC, com 1 min de imersão em cada, por 2000 ciclos. Os resultados para o teste de RF e ME mostraram que os valores para estas duas propriedades diminuíram em função da profundidade e após a realização da termociclagem para todas as resinas estudadas. Apenas a resina TNBF não apresentou diferença estatística para valores de ME após o envelhecimento acelerado. Quanto à dureza, os valores também diminuíram em função da profundidade, porém aumentaram após a realização do envelhecimento acelerado. Apenas a resina SF não apresentou diferença estatística entre os valores de dureza antes e após o envelhecimento. A resina convencional CD após a ciclagem térmica foi a única que apresentou relação base/topo (2 mm) acima de 80%. Nenhuma das resinas do tipo bulk fill apresentou uma relação base/topo acima de 80% para a dureza quando avaliadas na espessura máxima recomendada. Com base nos resultados obtidos, pode-se afirmar que, quando fotoativadas na espessura máxima recomendada, apenas a resina convencional CD apresentou resultados condizentes com a homogeneidade esperada em todas as condições deste estudo. Entretanto, para as resinas do tipo bulk fill, pode-se observar que as propriedades estudadas, de modo geral, sofreram uma diminuição significativa em função da profundidade. Para o envelhecimento, a dureza, diferentemente dos outros parâmetros, mostrou uma tendência de aumento. / The purpose of this study was to evaluate the performance of four bulk fill resins (Filtek Bulk Fill (FBF), Opus Bulk Fill (OBF), Sonicfill (SF) and Tetric N-Ceram Bulk Fill (TNBF)) and a conventional resin (Charisma Diamond (CD)) for the following properties: flexural strength (FS), flexural modulus (FM) and Knoop hardness (KHN) as a function of depth and after accelerated aging. Specimens were made simultaneously with different depths (1, 2, 3, 4 and 5 mm) for flexural strength tests (n = 10), flexural modulus (n = 10) and Knoop hardness (n = 3). The tests were carried out in two moments, before and after the accelerated aging process, which consisted of thermocycling with alternating baths in water at 5 and 55ºC, with 1 min immersion in each, for 2000 cycles. The results for the FS and FM tests showed that the values for these two properties decreased as a function of depth and after the thermocycling for all the studied resins. Only TNBF resin showed no statistical significant differences in FM values after accelerated aging. For the hardness test, values also decreased as a function of depth, but increased after accelerated aging. SF resin was the only one that showed no statistical significant differences between hardness values before and after aging. CD, after thermal cycling, was the exclusive resin to show a bottom/top ratio above 80%. None of the bulk fill resins had a bottom/top ratio above 80% for hardness when evaluated at the maximum recommended thickness. Based on the results obtained, it can be stated that, when photoactivated at the maximum recommended thickness, only the conventional resin CD presented results consistent with the expected homogeneity in all the conditions of this study. However, for bulk fill resins, it can be observed that the studied properties, in general, suffered a significant decrease as a function of depth. For aging, the hardness, unlike the other parameters, showed a tendency to increase.
118

Análise do efeito de adição do marcador Rodamina B em propriedades mecânicas de sistemas adesivos não simplificados / Analysis of the effect of addition of Rhodamine B marker on mechanical properties of non-simplified adhesives

Machado, Camila Moreira 12 December 2014 (has links)
Este estudo in vitro avaliou o efeito da adição de rodamina B dissolvida em etanol nas concentrações de 0,02mg/mL e 0,10mg/mL, nas propriedades mecânicas dos sistemas adesivos não simplificados considerados padrão-ouro. 96 coroas de terceiros molares humanos hígidos foram seccionadas transversalmente no terço oclusal para remoção do esmalte e exposição da dentina. Os espécimes foram divididos de acordo com os sistemas adesivos Adper Scotchbond Multi-Purpose (MP) - convencional de três passos ou Clearfil SE Bond (SE) - autocondicionante de dois passos: MP-C e SE-C (MP e SE controles); MP-C1 e SE-C1 (MP e SE com rodamina B 0,02mg/mL); MP-C2 e SE-C2: (MP e SE com rodamina B 0,10mg/mL). Para o teste de RU, os espécimes (n=10) foram submetidos ao desgaste com lixas de granulação 320 e 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e restaurada com resina composta FiltekTM Z250. Após o armazenamento em saliva artificial (7dias/37oC), os espécimes foram seccionados para obtenção de palitos com 0,64 mm2 de área média e submetidos ao teste de microtração em máquina de teste universal a 0,5 mm/min, que foram analisados após 7 dias e 6 meses. O modo de fratura dos espécimes foi analisado com estereomicroscópio digital (x200) e classificado em: adesiva, coesiva em dentina, coesiva em resina e mista. Para o teste de MS, as coroas seccionadas (n=6) foram planificadas com lixa de granulação 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e os espécimes foram mantidos secos em estufa a 37oC durante 48 horas. O teste de MS foi realizado utilizando ponta Knoop (Microdurômetro Shimadzu HMV-2), a 10x e carga estática de 25gF por 10 segundos. Os resultados obtidos foram analisados por análise de variância (ANOVA-2 critérios) e teste de Bonferroni para comparações múltiplas (p<0,05). A análise de acordo com o tempo foi realizada com o teste de t-student. Os valores médios de RU e desvio padrão (MPa±dp; 7 dias / 6 meses) foram: MP-C (41,95±2,38 / 22,76±3,66); MP-C1 (28,02±5,12 / 17,93±5,70); MP-C2 (26,28±5,55 / 14,30±5,68); SE-C (46,07±1,43 / 19,07±6,75); SE-C1 (37,49±13,31 / 18,54±6,71); SE-C2 (34,16±7,71 / 17,89±4,87). No tempo de 7 dias, os fatores sistema adesivo e concentração de rodamina B foram significantes. Após 6 meses, apenas o fator concentração de rodamina B foi significante. A falha de fratura predominante em todos os grupos foi adesiva. Os valores de MS (KHN) e desvio padrão foram: MP-C (8,97±3,85); MP-C1 (7,33±0,99); MP-C2 (7,17±2,45); SE-C (4,71±4,42); SE-C1 (4,42±0,56); SE-C2 (3,27±0,30). Na comparação entre os sistemas adesivos, eles diferiram entre si na condição controle e de 0,10mg/mL. Para cada adesivo, não houve diferença entre as distintas condições de acordo com a adição de rodamina B. Em função dos resultados apresentados, a adição de rodamina B nos sistemas adesivos não simplificados MP e SE, nas concentrações de 0,02mg/mL e 0,10mg/mL, deve ser incorporada com cautela para que não influencie nas propriedades mecânicas do material. / This in vitro study evaluated the effect of addition of rhodamine B dissolved in ethanol in concentrations of 0.02mg/mL and 0.10mg/mL, the mechanical properties of non-simplified adhesive systems. 96 crowns of human third molars were transversely sectioned on the oclusal third to remove the enamel and exposure the dentin. The specimens were divided according to the adhesive systems Adper Scotchbond Multi-Purpose (MP) 3-step-etch-andrinse or Clearfil SE Bond (SE) 2-step-self-ecthing: MP-C and SE-C (MP and SE controls); MP-C1 and SE-C1 (MP and SE with 0.02mg/mL rhodamine B); MP-C2 and SE-C2: (MP and SE with 0.10mg/mL rhodamine B). For the &#x3BC;TBS test, the specimens (n=10) were ground with 320- to 600-grit silicon carbide paper. The dentin was treated according to the instructions of each manufacturer and restored with composite resin FiltekTM Z250. The specimens were stored in artificial saliva (7 days/37oC), and then sectioned to obtain sticks with an average of 0.64 mm2 area and submitted to &#x3BC;TBS test at a universal testing machine at 0.5 mm/min, which were analyzed immediately after 7 days and 6 months. The mode of fracture of the specimens was analyzed with digital stereomicroscope (x200) and classified as: adhesive, cohesive in dentine, cohesive in resin and mixed. For the SM test, the sectioned crowns (n=6) were flattened with 600-grit silicon carbide paper. The dentin was treated according to the manufacturers instructions for each adhesive system and the specimens were stored in dry condition at 37oC during 48 hours. The SM test was performed with Knoop indenter (Shimadzu HMV-2 hardness tester), at 10x and 25gF of load for 10 seconds. The results were analyzed by two-way analysis of variance tests and the Bonferroni test for multiple comparisons (p<0.05). The analysis regarding time was checked with t-student test. The mean &#x3BC;TBS and standard deviation (MPa±dp; 7 days / 6 months) were: MP-C (41.95±2.38 / 22.76±3.66); MP-C1 (28.02±5.12 / 17.93±5.70); MP-C2 (26.28±5.55 / 14.30±5.68); SE-C (46.07±1.43 / 19.07±6.75); SE-C1 (37.49±13.31 / 18.54±6.71); SE-C2 (34.16±7.71 / 17.89±4.87). In the immediate time, the adhesive system and rhodamine B concentration factors were significant. After 6 months, only the rhodamine B concentration was a significant factor. The predominant failure in all groups was adhesive. The values of SM and standard deviation were: MP-C (8.97±3.85); MP-C1 (7.33±0.99); MP-C2 (7.17±2.45); SE-C (4.71±4.42); SE-C1 (4.42±0.56); SE-C2 (3.27±0.30). In the comparison between the adhesive systems, they were significantly different for the conditions control and 0.10mg/mL. For each adhesive systems, there was no difference between the different conditions according to the addition of rhodamine B. Regarding the shown results, addition of rodhamine B in non-simplified adhesives MP and SE, in the concentrations of 0.02mg/mL e 0.10mg/mL must be carefully added to avoid implications to the mechanical properties of the materials.
119

Rugosidade superficial e microdureza de materiais restauradores provisórios submetidos a ação de enxaguatórios bucais / Surface roughness and microhardness of provisory restorative materials submitted to mouthwashes

Arnez, Mayara Manfrin 09 January 2017 (has links)
O objetivo deste estudo foi avaliar a rugosidade superficial (&micro;m) e microdureza Vickers (VH) de materiais restauradores temporários: cimento Biodentine&trade; (M1) e o cimento de ionômero de vidro - Fuji IX (M2) submetidos a diferentes enxaguatórios bucais. Foram confeccionados 54 corpos de prova (cps) por meio de uma matriz de teflon (6mm x 2mm), distribuídos aleatoriamente em 6 grupos de acordo com a solução utilizada: água destilada (S1), enxaguatório com álcool - Listerine Cool Mint (S2) e enxaguatório sem álcool - Colgate Plax (S3). Todos os cps foram mantidos em umidade relativa de 100%, em estufa 37±1°C durante todo o experimento, exceto nos períodos de imersão nos enxaguatórios estabelecidos. Os cps foram colocados individualmente em um frasco contendo 8mL do enxaguatório específico para cada grupo, durante 2 minutos, sob vibração, duas vezes ao dia, por um período de 21 dias. As leituras foram realizdas por meio do microdurômetro e rugosímetro nos tempos de 48 horas (T0), 7 dias (T1), 14 dias (T2) e 21 dias (T3). Os dados obtidos foram agrupados em tabelas e submetidos aos testes estatísticos de normalidade, Kolmogorov-Smirnov, Shapiro-Wilk, Anova e Teste de Tukey por meio do Programa Estatístico Assistat Versão 7.7 beta (2016). Resultados: Verificou-se que os fatores Tempo (T), Solução (S) e Material (M) isoladamente e a interação TxM e SxM tiveram efeito estatisticamente significante na rugosidade superficial. Isoladamente, T3 (0,92±0,02) e M1 (0,87±0,01) apresentaram maior média de rugosidade e S3 (0,72±0,02) a menor média de rugosidade. Nas interações MxT e SXM, respectivamente o M1T3 (1,10±0,03) e M1S1 (1,03±0,03) apresentaram maiores médias de rugosidade. Para a microdureza o fator Material isoladamente, e a interação TxS, TxM e SxM tiveram efeito estatisticamente significante. O M1 (61,2±0,87) apresentou maior microdureza, que M2 (54,4±0,87). Para a interação TxS, a condição S2T2 (54,09±2,61) apresentou menor média de microdureza. Para a interação TxM, o M1 comparado com M2 determinou maior microdureza nos tempos T0, T1 e T2. E para a interação SxM, M1S1 (61,59±1,51) e M1S2 (62,86±1,51) apresentaram maior microdureza que M2S1 (51,53±1,51) e M2S2 (54,34±1,51). De acordo com a metodologia pode-se concluir que: a) o M1 apresentou maior rugosidade superficial nos tempos T1, T2 e T3 e maior microdureza nos tempos T0, T1, e T2 do que o M2 b) O material M1 apresentou maior microdureza independente das soluções. / The aim of this study was to evaluate the surface roughness (&micro;m) and Vickers microhardness of provisory restorative materials: BiodentineTM (M1) and Fuji IX - glass ionomer cement (M2) were submitted to different mouthwashes. Fifty-four specimens were prepared using a Teflon mold (6mm x 2mm), randomly distributed into 6 groups according to the solution used: distilled water (S1), mouthwash containing alcohol -Listerine Cool Mint (S2) and alcohol-free mouthwash - Colgate Plax (S3). During the experiment, all specimens were carried out at a relative humidity of 100% in an oven at 37±1°C, except in the soaking periods in the established mouthwashes. The samples were individually placed in a flask containing 8mL of the specific mouthwash for each group for 1 minute, under vibration twice a day for a period of 21 days. The readings of the variables were carried out at the time of 48 hours (T0), 7 days (T1), 14 days (T2) and 21 days (T3). The obtained data were grouped in tables and submitted to the Normality Tests for Statistical Analysis Kolmogorov-Smirnov, Shapiro-Wilk, Anova and Tukey\'s Test provided by the Statistical software Assistat Program Version 7.7 beta (2016). Results: It was found that there was a significant effect on surface roughness when considered alone Time (T), Solution (S), Material (M) and the interaction between TxM and SxM. On the other hand, T3 (0.92±0.02) and M1 (0.87±0.01) presented the higher roughness and S3 (0.72±0.02) the lowest average roughness. For the interactions MxT and SxM, M1T3 (1,10±0,03) and M1S1 (1,03±0,03) presented higher roughness averages. To microhardness analysis, the material as a alone factor and the interaction TxS, TxM and SxM had a statistically significant effect. M1 (61.2±0.87) presented a higher microhardness than the M2 (54.4±0.87). For the TxS interaction, S2T2 (54.09 ± 2.61) had a lower microhardness average. To TxM interaction, the M1 compared to M2 determined a higher microhardness at T0, T1 and T2. In interaction SxM, M1S1 (61.59±1.51) and M1S2 (62.8 ±1.51) had a higher microhardness than M2S1 (51.53±1.51) and M2S2 (54.3 ±1,51). According to the methodology, it can be concluded that: a) M1 presented greater surface roughnes at T1, T2 and T3 and higher microhardness at T0, T1, and T2 than M2 b) M1 presented a higher microhardness than M2 for S1 and S2.
120

Estudo da resistência ao desgaste de um ferro fundido branco de alto crómio

Afonso, André Filipe Martins January 2012 (has links)
Estágio realizado na Cruz Martins & Wahl, Lda. - e orientado pelo Eng. Carlos Dias / Tese de mestrado integrado. Engenharia Metalúrgica e de Materiais. Faculdade de Engenharia. Universidade do Porto. 2012

Page generated in 0.0546 seconds