• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 334
  • 16
  • 9
  • 9
  • 9
  • 9
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 359
  • 248
  • 94
  • 80
  • 69
  • 56
  • 54
  • 54
  • 51
  • 51
  • 50
  • 44
  • 43
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estudo in vitro da influência da dureza e módulo de elasticidade de sistemas adesivos na resistência de união à dentina humana / In vitro study of influence of hardness and elasticity module of adhesive sistems in bond strenght to human dentin

Camilla Regina Galvão Bengtson 01 February 2011 (has links)
O objetivo deste trabalho foi avaliar a dureza e o módulo de elasticidade da região de adesão quando utilizados diferentes sistemas adesivos e uma resina composta imediatamente após o procedimento adesivo e após 6 meses de armazenamento, correlacionando esses valores com a resistência adesiva à dentina humana. Para isso foram medidos a dureza e o módulo de elasticidade da resina composta junto à área de união, da camada de adesivo, da camada híbrida, e da dentina adjacente utilizando testes de nanoendentação. Foram utilizados 40 molares humanos hígidos (n=10). Os dentes foram preparados de modo a obterem-se superfícies planas em dentina, sobre as quais os sistemas adesivos foram aplicados seguindo as instruções dos fabricantes. Foram utilizados quatro sistemas adesivos de diferentes formas de aplicação (Adper Scotchbond Multiuso, Adper Single Bond 2, Adper SE Plus e Clearfil SE Bond). Sobre essas superfícies foram inseridos incrementos de resina composta perfazendo 5 mm de altura. Após 24h de armazenamento em água destilada à 37ºC. Os dentes restaurados foram seccionados para obterem-se corpos-de-prova com área aderida de 1mm2. Dos corpos de prova viáveis, 2 palitos centrais de cada dente foram selecionados para análise da nanodureza e do módulo de elasticidade da interface adesiva. Os demais tiveram a resistência de união testada através do teste de microtração, sendo metade desses corpos de prova armazenados durante 6 meses em água à 37ºC. Foi aplicado o teste estatístico ANOVA para dois fatores para todas as variáveis do estudo. Para o fator tempo foi detectada diferença estatística entre os grupos para a resistência adesiva (p=0,042), para o módulo de elasticidade do adesivo (p=0,000) e nanodureza do adesivo (p=0,000), sendo os valores mais baixos observados após 6 meses de armazenamento. Para o fator adesivo, todos os grupos apresentaram diferenças estatísticas (p=0,000), exceto para a variável nanodureza da camada híbrida (p=0,255). O sistema adesivo Clearfil SE Bond apresentou os melhores valores para resistência adesiva e módulo de elasticidade da camada híbrida, juntamente com o sistema Scothbond Multiuso. Os piores desempenhos foram demonstrados pelo sistema adesivo Adper SE Plus. Para a interação, apenas a variável nanodureza do adesivo apontou diferença entre os grupos (p=0,028). O teste de correlação de Pearson detectou correlação significante para as variáveis de módulo de elasticidade, sendo negativa para o módulo de elasticidade do adesivo e positiva para o módulo de elasticidade da camada híbrida. A metodologia e os resultados apresentados permitem-nos concluir que as propriedades mecânicas estudadas (resistência adesiva, módulo de elasticidade do sistema adesivo e da camada híbrida, nanodureza do sistema adesivo e da camada híbrida) podem variar dependendo do sistema adesivo utilizado e do tempo de armazenamento após o procedimento adesivo ter sido realizado. Além disso, quanto maior o módulo de elasticidade da camada híbrida apresentado por um sistema adesivo maior será sua resistência adesiva e menor será o módulo de elasticidade apresentado pela camada de adesivo. / The aim of this study is to evaluate hardness and elasticity module of adhesive region of adhesive systems of different formulations immediately and 6 moths after the adhesive procedures. Those values will be compared to microtensile bond strength to human dentin. The hardness and elasticity module of composite resin next to adhesion region, adhesive layer, hybrid layer and dentin were evaluated. Forty sound human molars were used and prepared in order to obtain flat dentin surfaces in which the adhesive systems were applied following manufactures instructions (n=10). The groups were divided according the four adhesive systems: Adper Scotchbond Multipurpose, Adper Single Bond 2, Adper SE Plus and Clearfil SE Bond. Resin blocks of 5mm were constructed in those surfaces. After 24h of storage in distilled water at 37°C restored teeth were sectioned in order to obtain specimen with a bonded area of around 1mm2. Two specimen of each tooth were submitted to nanohardness and elasticity module test of adhesive interface. Half of the specimen were immediately submitted to the test with a crosshead speed of 0,5mm/min until fracture, the other specimen were stored for additional 6 month in 37ºC water prior to the test. The values resulting of all variables of the study were compared using ANOVA two-way. For the time factor, it was detected statiscal difference between groups in microtensile bond strength values (p=0,042), adhesive elastic modulus (p=0,000) and adhesive nanohardnes (p=0,000), the lowest values were observed in 6 months of storage. For adhesive factor, all groups presented statistical difference (p=0,000), except hybrid layer nanohardness (p=0,255). Clearfil SE bond and Scothbond systems presented the best values of bond strength and hybrid layer elastic modulus. The worse performance was demonstrated by Adper SE Plus adhesive system. For the interaction, only the adhesive nanohardness presents difference between groups (p=0,028). The Pearson correlation test detected positive correlation with microtensile bond strength tests and hybrid layer elastic modulus and negative correlation with bond strength and adhesive elastic modulus. The methodology and the results allow us to conclude that the studied mechanical properties (bond strength, modulus of elasticity of the adhesive and hybrid layer, nanohardness adhesive system and the hybrid layer) may vary depending on the adhesive system and time storage after the bonding procedures have been performed. Moreover, when an adhesive system presents a high elastic modulus of hybrid layer, it will present a high bond strength and low elastic modulus of adhesive layer.
82

Avaliação dos efeitos promovidos pela radiação azul na remineralização do esmalte dentário in vitro / EFFECTS OF BLUE LIGHT IRRADIATION ON DENTAL ENAMEL REMINERALIZATION IN VITRO

Ilka Tiemy Kato 03 September 2009 (has links)
Este trabalho foi desenvolvido com o objetivo de avaliar os efeitos da luz azul na remineralização do esmalte. Adicionalmente foi desenvolvida uma metodologia de análise para a avaliação de alterações minerais do esmalte dental por meio da tomografia por coerência óptica. Lesões foram formadas em amostras de esmalte dental bovino por meio da imersão em solução tampão de acetato subsaturado (2 mL/mm2 e 6,25 mL/mm2) por 32 h. As amostras foram irradiadas com um LED azul com emissão em 455±20 nm, potência de 110 mW, irradiância de 1,4 W/cm2, tempo de irradiação de 10 s e exposição radiante de 13,8 J/cm2. Posteriormente, as amostras foram submetidas à ciclagem de pH durante oito dias à 37 oC para induzir a remineralização. A avaliação do conteúdo mineral foi realizada por meio do teste de dureza seccional e por tomografia por coerência óptica (OCT). Na avaliação por dureza observou-se que as amostras do grupo irradiado apresentaram menor conteúdo mineral que as amostras do grupo não irradiado. A diferença entre os grupos foi mais evidente nas amostras submetidas à formação de lesão em maior volume de solução desmineralizadora. Por meio da técnica de OCT foram observadas diferenças significativas entre o sinal do esmalte hígido e desmineralizado. Após a remineralização, as amostras irradiadas apresentaram menor conteúdo mineral que as não irradiadas; porém, não foram observadas diferenças significativas entre os grupos. Com base nos resultados deste estudo, pode-se concluir que a irradiação com luz azul (l=455nm) promoveu a inibição da remineralização do esmalte dental. A metodologia empregada nas análises por OCT permitiu a avaliação quantitativa da perda mineral no esmalte; porém, este resultado não foi alcançado na avaliação da remineralização. / This study aimed to investigate the effects of blue radiation on dental enamel remineralization. In addition, a methodology of analysis was developed to evaluate alterations of enamel mineral content by optical coherence tomography. Artificial lesions were formed in bovine dental enamel slabs by immersing the samples in undersaturated acetate buffer (2 mL/mm2 e 6.25 mL/mm2). The lesions were irradiated with blue LED (l=455±20nm), with radiant power of 110 mW, irradiance of 1.4 W/cm2, radiant exposure of 13.8 J/cm2 and exposure time of 10 s. Remineralization was induced by pH-cycling model during 8 days. Cross-sectional hardness and optical coherence tomography (OCT) were used to assess mineral changes after remineralization. Hardness data showed that non-irradiated enamel lesions presented higher mineral content than irradiated ones and this difference was more evident in lesions formed in higher solution volume. The analysis of OCT signal also demonstrated that the mineral content of non-irradiated group was higher than in irradiated one; however, no significant difference was observed. Furthermore, significant differences in OCT sign were detected between sound and demineralized enamel. Based on the results obtained in the present study it can be concluded that blue radiation caused an inhibition of enamel remineralization. The methodology adopted for OCT analysis allowed the quantification of enamel mineral loss; however, the remineralization process could not be evaluated by this technique.
83

Filmes finos depositados pela técnica de implantação iônica por imersão em plasma e deposição (IIIPD), utilizando o monômero HMDSN e os gases argônio, hélio e nitrogênio /

Kodaira, Felipe Vicente de Paula. January 2016 (has links)
Orientador: Rogério Pinto Mota / Banca: Milton Eiji Kayama / Banca: Rodrigo Savio Pessoa / Resumo: Filmes finos poliméricos depositados a plasma são de grande utilidade em diversas aplicações industriais e científicas, em áreas como eletrônica, mecânica, revestimentos, biomateriais, entre outras, devido a propriedades interessantes como: boa adesão ao substrato, estrutura entrelaçada, espessura nanométrica, homogeneidade, entre outros. Neste trabalho, filmes finos poliméricos foram depositados utilizando-se a técnica de implantação iônica por imersão em plasma e deposição a partir das misturas entre o monômero hexametildisilazano e os gases argônio, hélio e nitrogênio. Foram variadas as concentrações gás/monômero nestas misturas e a potência de deposição. Os filmes obtidos passaram por caracterizações de ângulo de contato, energia de superfície, dureza, espessura, índice de refração e estrutura molecular. Para todas as condições avaliadas, o filme apresentou-se transparente, com valores para o índice de refração variando entre 1,56 e 1,70. Os filmes poliméricos também se mostraram hidrofóbicos, com valores para o ângulo de contato próximos a 100 graus. Os valores para a dureza foram de 0,7 a 2,6 GPa. A espessura dos filmes para diferentes condições variaram entre, aproximadamente, 100 e 200 nm. A análise da estrutura molecular permitiu observar que os mesmos grupos funcionais estão presentes em todos os filmes depositados, porém a variação dos parâmetros favorece o aumento de determinados grupos em detrimento de outros. A partir destas caracterizações, foi possível observar que variações nos parâmetros do plasma interferem diretamente nos filmes resultantes / Abstract: Polymeric thin films deposited by plasma technique are very attractive for many industrial and scientific applications in areas such as electronics, mechanics, coatings, biomaterials, among others, due to favorable properties such as good adhesion to the substrate, high crosslinking, nanomectric thickness, homogeneity, etc. In this work, polymeric thin films were deposited by Plasma Immersion Ion Implantation and Deposition (PIIID) technique from mixtures between hexamethyldisilazane and the gases argon, helium and nitrogen. The gas/monomer concentration in these mixtures and deposition power were varied. The grown films were characterized by their contact angle, surface energy, hardness, thickness, refractive index and molecular structure. For all the evaluated conditions, the film showed itself transparent, with refractive index values ranging from 1.56 to 1.70. The polymeric films were also hydrophobic, with contact angle values around 100 degrees. The hardness values ranged from 0.7 to 2.6. The thickness for different conditions of PIIID, ranged from 100 to 200 nm. The molecular structure analysis showed that the same functional groups were present in all the deposited films; however the parameter variation favored the growth of certain groups over others. From these characterizations, it was possible to observe that changes in the plasma parameters interfere directly in the produced films / Mestre
84

Influência das unidades fotoativadoras e do material restaurador indireto sobre a dureza de um cimento resinoso dual auto-adesivo e um cimento resinoso dual convencional por meio de teste de nanoendentação / Influence of curing units and restorative indirect material on hardness of a dual cure self-adhesive resin cement and dual cure conventional resin cement through nanoindentadion test

Kuguimiya, Rosiane Nogueira 05 December 2013 (has links)
O objetivo deste estudo foi avaliar a dureza de um cimento resinoso dual autoadesivo (RelyX U200) e um cimento resinoso dual convencional (RelyX ARC) fotoativados sob materiais restauradores indiretos, utilizando unidades fotoativadoras com diferentes comprimentos de ondas (LED Elipar Freelight 2, LED Bluephase, Laser AccuCure 3000TM), por meio de teste de nanoendentação. Para a obtenção dos espécimes foram utilizados incisivos bovinos que após profilaxia, foram submetidos a cortes no limite amelo-cementário para a separação da porção coronária. Após inclusão, os espécimes foram submetidos ao desgaste para exposição de dentina e padronização do substrato. Para simular clinicamente restaurações indiretas foram confeccionadas peças em cerâmica IPS e.max® Press (Ivoclar Vivadent) e em resina composta indireta SR Adoro (Ivoclar Vivadent) que foram cimentadas nas superfícies dentinárias. Os espécimes foram seccionados longitudinalmente em baixa velocidade e constante irrigação e polidos em politriz. Foi estabelecido um grupo controle positivo, no qual o cimento foi fotoativado sem a interposição de material restaurador indireto e um grupo controle negativo, no qual, após a cimentação do material restaurador indireto, a fotoativação foi suprimida, ocorrendo apenas a polimerização química do cimento. Todos os espécimes foram armazenados em água destilada a 37°C durante 7 dias e após esse período, foram submetidos ao teste de nanoendentação na linha de cimentação, com o auxílo do ultra-microdurômetro (Shimadzu Dynamic Ultra Micro Hardness Tester). O ciclo aplicado foi de 100mN. Foram realizadas cinco nanoendentações em cada espécime, cujas médias resultaram nos valores de cada superfície. Os resultados obtidos foram submetidos à Análise de Variância e Teste de Tukey (p<0,05). Podese concluir que o cimento RelyX ARC apresentou maiores valores de dureza do que o RelyX U200 e este foi mais dependente da fotoativação para alcançar uma polimerização adequada. A dureza dos cimentos resinosos avaliados foi influenciada negativamente pela interposição do material restaurador indireto e apenas os LEDs foram capazes de manter o mesmo grau de polimerização dos cimentos quando interposto um material restaurador indireto. / This study aimed to evaluate the hardness of a dual cure self-adhesive resin cement (RelyX U200) and a dual cure conventional resin cement (RelyX ARC) light curing units with different wavelengths (Elipar Freelight 2 LED, Bluephase LED, AccuCure 3000TM Laser) through nanoindentadion test. To obtain the specimens bovine incisors were used after prophylaxis. The tooth were sectioned at the limit amelocement for the separation of the coronal portion. After inclusion, the dentin surface of the specimens were exposed to standardize the substrate. To clinically simulate indirect restorations ceramic pieces were made (IPS e.max® Press/Ivoclar Vivadent) and indirect composite resin (SR Adoro/Ivoclar Vivadent) were cemented on dentin surfaces. The specimens were sectioned longitudinally at low speed with constant irrigation and polished. A positive control group was stablished, in which the cement was light cured without the interposition of indirect restorative material, and a negative control group, in which, after cementation of the indirect restorative material, the light curing was removed, occurring only the chemical polymerization of the cement. All specimens were stored in distilled water at 37°C for 7 days. Nanoindentadion hardness of the cement layer was measured under 100mN load (Shimadzu Dynamic Ultra Micro Hardness Tester). Five nanoindentations in each specimen were obtained, which resulted in the average values of each surface. Data were statistically analyzed using ANOVA and Tukey test (p<0,05). RelyX ARC pesented higher values of hardness than RelyX U200 and this was more dependent on the polymerization. The hardness of the evaluated resin cements was negatively influenced by the interposition of an indirect restorative material and only the LEDs were able to maintain the same degree of polymerization of the cement when an indirect restorative material was used.
85

Estudo da eficiência de aparelhos para fotopolimerizar resinas odontológicas. / Analysis of the efficiency from visible-light sources used to polimerize odontological resins.

Silva, Ines Regina 04 October 1993 (has links)
Neste trabalho foram caracterizados cinco fotopolimerizadores, Visilux 2, Resilux, Fibralux, Translux III e Primelite. Inicialmente foram obtidos os espectros de emissão das cinco fontes de luz com um monocromador, e a estes espectros foram ajustadas funções gaussianas. Os melhores ajustes foram obtidos com um somatório de funções gaussianas, que originaram uma função matemática característica para cada uma das fontes de luz. Foi obtido também o espectro de absorção ótica da resina composta utilizada, no intervalo de 350-600 nm do espectro eletromagnético, e observou-se que havia uma absorção maior para comprimentos de onda menores. Foram calculados os valores dos coeficientes de atenuação linear para as lamínulas e para as amostras de resina, e observou-se que para uma mesma fonte de luz, haviam variações dos valores do coeficiente de atenuação linear para as diferentes espessuras, tanto das lamínulas como das amostras, concluindo-se que o sistema não estava em equilíbrio. As fontes de luz utilizadas foram ordenadas de acordo com a sua eficiência na polimerização da resina, através dos valores de dureza durante a polimerização da amostra, na seguinte ordem: Visilux 2, Translux III, Resilux, Fibralux, Primelite. / In this work, five photopolymerizators was characterized, Visilux 2, Resilux, Fibralux, Translux III and Primelite. Initially the emission specter from five light sources was obtained with a monochromator, and to these specters was adjusted gaussians functions. The better adjustments was obtained with a sum of gaussian functions, originating a caracteristic mathematical function to each light source. The resin's optical absortion specter was obtained in the 350-600 nm interval from eletromagnetic specter, and was observed that was greater absorption for smaller weavelength. The values of linear attenuation coefficient from slabs and samples was calculated, and was observed that for one light source, there was variations in the values of linear attenuation coefficient to differents thicknesses, both to the slabs and the samples, concluding that the sistem was not in equilibrium. The light sources used was disposed in agreement to their efficience in the resin's polymerization, through the values of the hardness during the photopolymerization, in the order: Visilux 2, Translux III, Resilux, Fibralux and Primelite.
86

Análise da qualidade de polimerização, por meio de testes de microdureza, de um cimento resinoso utilizado na cimentação de coroas totais em preparos com diferentes substratos / Analysis of quality of polymerization of a resin cement used to cement ceramic crowns in differents preparation substrates through microhardness tests

Mendonça, Luana Menezes de 27 May 2011 (has links)
O objetivo deste estudo foi avaliar a microdureza do cimento resinoso Variolink II ( Ivoclar Vivadent, Schaan, Liechtenstein) empregado na cimentação de coroas totais de cerâmica (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) em preparos com 3 substratos (dentina, metal e resina composta). Foram utilizados 30 molares distribuídos em 3 grupos de acordo com o tipo de substrato. No grupo com substrato em dentina (D), as coroas foram cimentadas em dentes preparados em dentina. Nos grupos com substrato em metal (M) e resina (R), as coroas foram seccionadas no nível da junção cemento-esmalte e restauradas com núcleos metálicos e de preenchimento em resina composta, respectivamente. Cada um dos grupos foi subdividido em subgrupos para avaliação após 7 dias e 3 meses de armazenamento em água deionizada. Os espécimes foram seccionados no centro das coroas, no sentido vestíbulo-lingual e as superfícies foram polidas para a realização dos testes de microdureza ao longo da linha de cimento. Os valores de microdureza foram obtidos nos terços cervical, médio, oclusal das faces vestibular e lingual e na face oclusal. Os resultados foram submetidos a uma análise estatística prévia ANOVA a 3 critérios (substratos/ armazenamento/ terços e face oclusal), a qual não mostrou diferenças significativas entre os terços e face oclusal nos 2 períodos de armazenamento. Em seguida foi realizada a ANOVA a 2 critérios (substrato e armazenamento) e o teste de Tukey que mostraram os resultados do substrato em resina estatisticamente inferiores aos de dentina e metal, após o período de armazenamento de 7 dias. Conclui-se que a microdureza do cimento resinoso não variou nos diferentes terços e face e que a influência do substrato em resina no cimento foi tempo-dependente. / The aim of this study was to evaluate the microhardness of resin cement Variolink II (Ivoclar Vivadent, Schaan, Liechtenstein) used to cement full ceramic crowns (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) in three preparations substrates (dentin, metal and composite resin). Thirty molars were divided into three groups, according to the type of the substrate. In the dentin substrate group (D), the crowns were prepared in dentin; the metal (M) and resin (R) substrates groups, the crowns were sectioned at cement enamel junction level and restored with metal cast post and composite resin filler, respectively. Each group was subdivided into subgroups to evaluation after 7 days and 3 months of storage in deionized water. After cementing the specimens were sectioned buccolingually at the center of the crowns, and the surfaces were polished to microhardness test along the cement line. The microhardness values were obtained in the cervical, medium and occlusion thirds of the buccal and lingual surfaces and in the occlusal surface. The results were submitted to a three-way ANOVA (substrates / storage / thirds and occlusal surface) to a prior statistical analysis and did not show significant differences between the occlusal surface and thirds in the two storage periods. Then two-way ANOVA (substrate and storage) and the Tukey test were performed. The results in the resin group were statistically lower than those of dentin and metal, after 7 days of storage. Therefore, the microhardness of resin cement did not change in the different thirds and face and that the influence of the resin substrate was time-dependent.
87

Efeito de um infiltrante resinoso no tratamento de lesões de mancha branca: análise in vitro e in situ / Efffect of a resinous infiltrant on the tratment of white spot lesions: in vitro and in situ analysis

Freitas, Maria Cristina Carvalho de Almendra 10 April 2015 (has links)
Dentre as estratégias de tratamento de lesões incipientes de cárie, no estágio de mancha branca ativa, o infiltrante resinoso tem sido empregado, preenchendo os poros do esmalte e impedindo a sua progressão. O objetivo deste trabalho foi avaliar o efeito do infiltrante de cárie (Icon®) sobre lesões cariosas artificiais produzidas por diferentes protocolos e a eficiência deste tratamento após novo desafio ácido por modelos experimentais in vitro e in situ, utilizando a microdureza de superfície (MS) e longitudinal (ML). Na fase in vitro, lesões cariosas artificiais foram produzidas em 45 espécimes de esmalte bovino (6x4mm) através de três diferentes protocolos (ciclagem DES-RE, gel MC e solução MHDP). Os espécimes foram tratados com o infiltrante e submetidos a novo desafio ácido por ciclagem DES-RE. Este delineamento resultou em 4 condições em um mesmo espécime: hígida (H), após a desmineralização (D), após o tratamento com o infiltrante (I) e após o novo desafio ácido (N). Na fase in situ, 15 voluntários usaram dispositivos palatinos contendo dois espécimes por 14 dias, induzindo a lesão por meio de gotejamento de solução de sacarose 8x/dia. Nas duas fases, a MS e ML foram avaliadas em todas as condições dos espécimes até 220&#x3BC;m. Os dados foram coletados e processados pela porcentagem da diferença com os valores iniciais da condição hígida para serem analisados estatisticamente de acordo com ANOVA (medidas repetidas) e teste de Tukey (p<0,05). No estudo in vitro e in situ todos os protocolos de desmineralização foram capazes de produzir lesões de cárie de subsuperfície. Todos os protocolos in vitro promoveram perda de dureza de superfície maior que 75%, enquanto o protocolo in situ promoveu quase 40%. Há uma redução da perda de dureza à medida que a profundidade aumenta em todos os casos, sendo as particularidades mais observadas até 50 &#x3BC;m. O infiltrante avaliado em todas as condições foi capaz de re-equilibrar parcialmente a dureza interna, entretanto sua resistência e efeito após o novo desafio ácido apresentou-se limitado. / Among the strategies for early caries lesions treatment as active white spot, the resin infiltrant has been employed filling the enamel pores and preventing their progression. The aim of this study was to evaluate the effect of caries infiltrant (Icon®) on artificial carious lesions produced by different protocols, and the efficiency of this treatment after new challenge acid by in vitro and in situ experimental models, using the surface microhardness (SH) and cross-sectional microhardness (CSH). In the in vitro phase, artificial carious lesions were performed on 45 enamel bovine specimens (6x4mm) by three different protocols (DE-RE cycling, MC gel and MHDP solution). The specimens were treated with the infiltrant and subjected to a new challenge by DE-RE cycling. This design resulted in four conditions at the same specimen: sound (S), after demineralization (D), after the treatment with infiltrant (I) and after the new acid challenge (N). In the in situ phase, 15 volunteers wore intraoral appliances containing two specimens for 14 days, inducing the lesion formation by sucrose solution dripping 8x/day. In both models, SH and CSH were evaluated in all conditions of the specimens up to 220&#x3BC;m. Data were collected and processed as percentage from the difference to each condition compared to sound stage to be statistically analyzed with ANOVA (repeated measures) and Tukey test (p <0.05). For all tested conditions, demineralization protocols were able to produce subsurface carious lesions. All in vitro protocols promoted hardness loss higher than 75% while in situ protocol promoted almost 40%. There is a reduction in the hardness loss as the depth increases, in which the main differences can be noticed up to 50&#x3BC;m. The infiltrant evaluated in all conditions was able to partially re-balance the internal hardness, however its strength and effect after the new challenge acid had been limited.
88

Influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada híbrida e camada de adesivo / The influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the hybrid layer and adhesive layer

Lobo, Tamile Rocha da Silva 03 September 2013 (has links)
Este estudo avaliou a influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada de adesivo e camada hibrida de uma resina composta à dentina humana, por meio de ensaio de microtração e nanoedentação. Os fatores de variação estudados foram dois sistemas adesivos com estratégias de aplicação distintas Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) e Clearfil SE Bond (Kuraray Co., Osaka, Japan), e ainda foram realizados tratamentos no substrato dentinário utilizando duas concentrações de digluconato de clorexidina sendo estas 2% e 0,2% e grupos controle sem tratamento com clorexidina. As unidades experimentais foram compostas por 48 molares humanos hígidos divididos aleatoriamente em 6 grupos (n=8). Nestes foram aplicados os procedimentos adesivos e realizados os tratamentos de superfície, com clorexidina, previamente aos procedimentos adesivos. Após esta etapa foram confeccionadas as restaurações com espessura de 5mm sobre as superfícies dentinárias. Após 24h de armazenamento em água destilada, os dentes restaurados foram cortados para a obtenção de corpos de prova em forma de palito, com secção transversal de aproximadamente 1mm2. De cada grupo foram selecionados aleatoriamente 5 palitos para o ensaio de dureza. O restante dos palitos viáveis de cada dente foram submetidos ao teste de microtração a uma velocidade de 0,5mm/min até que ocorresse a fratura da interface adesiva. Para o teste de nanoedentação cada um dos 5 palitos referentes aos 6 grupos estudados receberam 10 endentações, sendo 5 na camada de adesivo e 5 na camada hibrida, com distância de 10m entre si. Essas endentações foram realizadas com ultramicrôdurometro (DUH-W211S, Shimadzu Co., Tokyo, Japan). Os dados referentes aos testes de microtração dos seis grupos foram submetidos à análise de variância e teste de Tukey (p<0,05). As médias dos grupos foram: Grupo 1: Clearfil SE controle ( 28.50±0.47); Grupo 2: Adper Scotchbond controle (43.90±7.26); Grupo3: Clearfil SE/ clorexidina 2% (30.43±6.59); Grupo 4: Adper Scotchbond/ clorexidina 2% (39.21±4.69); Grupo 5: Clearfil SE 0,2%( 27.28±7.05); Grupo 6: Adper Scotchbond/ clorexidina 0,2% (35.70±6.43). Na comparação entre as médias dos grupos obteve-se que nenhum dos adesivos testados apresentou alteração na sua resistência de união com o uso do digluconato de clorexidina a 2% ou a 0,2% em análise imediata. Os grupos em que foi utilizado o adesivo Scotchbond apresentaram maiores valores de resistência de união que os grupos em que foi utilizado o sistema adesivo autocondicionante (Clearfil) independente da realização ou não do tratamento de superfície com digluconato clorexidina. Os valores de dureza da camada de adesivo não apresentaram diferenças estatisticamente significantes entre os grupos controle ou entre tratamentos, apenas o grupo com tratamento prévio Clearfil SE/Clorexidina 0,2% apresentou maior valores de dureza na camada de adesivo quando comparado ao grupo Scotchbond com a mesma concentração de clorexidina. Quanto aos valores de dureza da camada híbrida o grupo controle Clearfil SE quando comparado ao grupo Clearfil SE/Clorexidina 2% apresentou menor valor de dureza da camada hibrida. O Scotchbond controle apresentou menor valor de dureza na camada hibrida quando comparado ao grupo Scotchbond com clorexidina a 0,2%. O uso do digluconato de clorexidina nas concentrações 2% e 0,2% em dentina humana, apesar de ter apresentado discretas alterações na dureza da camada hibrida e camada de adesivo, não tiveram a capacidade de afetaram os valores de adesão à dentina dos diferentes adesivos testados. / This study evaluated the influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the adhesive layer and hybrid layer of a composite resin to dentin, using microtensile test and nanoindentation. The variation factors studied were two adhesive systems with different implementation strategies Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) and Clearfil SE Bond (Kuraray Co., Osaka, Japan), and were still held treatments to dentin using two concentrations of chlorhexidine digluconate and these 2% and 0.2% untreated control groups with chlorhexidine. The experimental units were composed of 48 human molars were randomly divided into 6 groups (n = 8). These procedures were applied adhesives and surface treatments performed with chlorhexidine prior to bonding procedures. After this step the restorations were made with 5mm thickness on the dentin surfaces. After 24 hours storage in distilled water, the samples were cut to obtain specimens toothpick shaped cross-section of approximately 1mm2. Each group were randomly selected 5 toothpicks for hardness testing. The remaining viable sticks of each tooth were subjected to microtensile testing at a crosshead speed of 0.5 mm / min until the fracture of the adhesive interface. To test nanohardness each of the five toothpicks referring to six groups received 5 indentations in the adhesive layer and 5 indentations in the hybrid layer with 10m away from each other. These indentations were performed with the equipament DUH-W211S (Shimadzu Co., Tokyo, Japan). The data relating to microtensile test of the six groups were subjected to analysis of variance and Tukey test (p <0,05). The means of the groups were: Group 1: Clearfil SE control (28.50 ± 0:47), Group 2: Adper Scotchbond control (43.90 ± 7.26); Group3: Clearfil SE / 2% chlorhexidine (30.43 ± 6:59), Group 4: Adper Scotchbond / 2% chlorhexidine (39.21 ± 4.69), Group 5: Clearfil SE 0.2% (27.28 ± 07.05), Group 6: Adper Scotchbond / chlorhexidine 0.2% (35.70 ± 6:43). Comparing the means of the groups it was found that none of the adhesives tested showed a change in its bond strength with the use of chlorhexidine gluconate 2% or 0.2% in immediate analysis. The groups that used Scotchbond showed higher bond strength than the groups that used the adhesive system (Clearfil) regardless of performance or not the surface treatment with chlorhexidine digluconate. The hardness values of the adhesive layer did not show statistically significant differences between the control groups or between treatments, the group previously treated with Clearfil SE / Chlorhexidine 0.2% showed higher hardness values in the adhesive layer when compared to Scotchbond with the same concentration of chlorhexidine. As for the hardness of the hybrid layer control group Clearfil SE when compared to Clearfil SE / 2% Chlorhexidine showed lower hardness value of the hybrid layer. The Scotchbond control showed lower hardness value in the hybrid layer when compared to Scotchbond with 0.2% chlorhexidine.The use of chlorhexidine gluconate at concentrations 2% and 0.2% in human dentin, despite having discrete changes in the hardness of the hybrid layer and adhesive layer, did not have the ability to affect the values of adhesion to dentin of different adhesives tested.
89

Comparação entre diferentes métodos para produção e análise de lesão de cárie artificial em esmalte e dentina / Comparison of different methods to produce and to analyze artificial enamel and dentin caries lesion

Moron, Bruna Mangialardo 26 September 2011 (has links)
Este trabalho comparou diferentes protocolos para a produção de lesão de cárie artificial em esmalte e dentina bovinos entre si e com lesões cariosas naturais (para o esmalte), utilizando análises de dureza superficial e longitudinal e microradiografia transversal, as quais foram relacionadas. Para o estudo in vitro, 40 espécimes de esmalte foram desmineralizados com: GEL MC (gel de metilcelulose 8% e ácido lático 0,1M, pH 4,6, 37ºC, 14 dias); GEL PA (solução de ácido poliacrílico - carbopol 0,2% e ácido lático 0,1M saturado com hidroxiapatita, pH 4,8, 37ºC, 16h); MDHP (solução de ácido lático 0,05M com cálcio, fosfato e tetraetil metilenodifosfanato, pH 5,0, 37ºC, 6 dias); e TAMPÃO (solução de ácido acético 0,05M com cálcio, fosfato e fluoreto, pH 5,0, 37ºC, 16h). Já os 60 espécimes de dentina foram desmineralizados com: GEL MC II (gel de carboximetilcelulose 6% e ácido lático 0,1M, pH 5,0, 37ºC, 14 dias); TAMPÃO II (solução de ácido acético 0,05M com cálcio, fosfato e fluoreto, pH 4,5, 37ºC, 7 dias); TAMPÃO III (solução de ácido acético 0,05M com cálcio e fosfato, pH 5,0, 37ºC, 7 dias) e MDHP II (solução de ácido lático 0,05M com cálcio, fosfato e tetraetil metilenodifosfanato, pH 5,0, 37ºC, 7 dias). No estudo in situ participaram 11 voluntários os quais utilizaram dispositivos palatinos de resina acrílica contendo dois espécimes de esmalte e dois de dentina bovinos, protegidos com uma tela plática, por 14 dias. Durante este período, os voluntários gotejaram uma solução de sacarose a 20% 8x/dia sobre o esmalte e 4x/dia sobre a dentina, para o desenvolvimento do biofilme. A desmineralização foi avaliada por dureza superficial-SH e longitudinal-CSH (KgF/mm2) e microradiografia transversal-TMR (%vol min). Foram ainda comparadas as lesões produzidas artificialmente em esmalte com as lesões naturais (mancha branca) de dentes extraídos. Os dados de CSH e TMR foram relacionados a cada distância e também submetidos individualmente à análise de variância para comparação entre os protocolos (p<0,05). Verificou-se que os diversos protocolos produziram diferentes tipos de lesões cariosas artificiais em esmalte e dentina. O grupo IN SITU, para ambos os substratos, produziu uma lesão profunda, com grande perda mineral integrada, porém com a menor camada superficial pseudo intacta. Já os grupos GEL MC I e II produziram lesões mais rasas e com menor perda mineral integrada. Os grupos MDHP I e II assim como TAMPÃO I, II e III produziram lesões subsuperficiais em esmalte e dentina. No geral, as lesões produzidas em dentina foram mais profundas e mais desmineralizadas quando comparadas ao esmalte. As lesões de mancha branca apresentaram-se com grande variabilidade em relação à profundidade e presença de camada superficial. Quanto ao método de avaliação, não houve uma relação linear entre CSH e TMR. Com base nos resultados, pode-se concluir que os métodos para produção de lesão cariosa diferem significativamente em relação às características de dureza e conteúdo mineral, podendo ter um impacto em uma subsequente des-remineralização e os métodos de análise não apresentam relação linear, sendo que a dureza deve ser interpretada criteriosamente em relação à perda mineral. / This study compared different methods to produce artificial dental caries in bovine enamel and dentin among them and with natural carious lesions (white sport lesion for enamel only) using surface and cross section hardness and transversal microradiography tests, which were submitted to relation analyses. For the in vitro study, 40 bovine enamel specimens were demineralized with: MC GEL (8% methylcellulose gel and 0.1M lactic acid, pH 4.6, 37ºC, 14 days), PA GEL (0,2% poliacrilic acid - carbopol and 0.1M lactic acid saturated with hydroxyapatite, pH 4.8, 37°C, 16h); MDHP (0,05M lactic acid solution with calcium, phosphate and tetraethyl methyl diphosphonate, pH 5.0, 37ºC, 6 days) and BUFFER (0.05M acetic acid solution with calcium, phosphate and fluoride, pH 5.0, 37ºC, 16h). Sixty dentin specimens were demineralized with: MC GEL (6% carboximetilcelulose gel and 0.1M lactic acid, pH 5.0, 37ºC, 14 days); BUFFER II (0.05M acetic acid solution with calcium, phosphate and fluoride, pH 4.5, 37ºC, 7 days); BUFFER III (0.05M acetic acid solution with calcium and phosphate, pH 5.0, 37ºC, 7 days) and MDHP II (0.05M actic acid with calcium, phosphate and tetraethyl methyl diphosphonate, pH 5.0, 37ºC, 7 days). For the in situ study, 11 volunteers wore acrylic resin palatal appliances containing two bovine enamel and dentin specimens, protected with plastic mesh, for 14 days. During this period, the volunteers dripped a 20% sucrose solution 8 times/day on enamel and 4 times/day on dentin, for the development of biofilm. Demineralization was assessed by surface (SH), cross-sectional (CSH) hardness and transversal microradiography (TMR). In addition, comparisons were made between artificially enamel caries lesions and natural lesions. The CSH and TMR data were correlated to each distance and also individually subjected to analysis of variance for comparison between protocols (p<0.05). It was found that the different protocols produced different types of artificial caries lesions in both enamel and dentin. The IN SITU protocol, for both substrates, produced a deep lesion with high integrated mineral loss, but with a thin surface layer. MC GEL I and II produced shallow lesions with low integrated mineral loss. MDHP I and II as well as BUFFER I, II and III protocols produced subsurface lesions in enamel and dentin. In general, the lesions produced in dentin were deeper and more demineralized when compared to enamel. The white spot lesions presented a high variability regarding lesion depth and surface layer. It was not found a linear relationship between CSH and TMR. Based on the results, it can be concluded that the protocols to produce artificial caries lesion significantly differ regarding hardness and mineral content, which in turn can influence further de-remineralization processes. The response variables do not present a linear relationship. Thus, hardness analysis should be carefully interpreted in respect to mineral loss.
90

"Estudos do desenvolvimento e caracterização das ligas Cu-Ni-Pt e Cu-Ni-Sn para fins eletro-eletrônicos" / STUDIES OF THE DEVELOPMENT AND CHARACTERIZATION OF THE Cu-Ni-Pt AND Cu-Ni-Sn ALLOYS FOR ELETRO-ELECTRONIC USES

Silva, Luis Carlos Elias da 04 October 2006 (has links)
O Cu e suas ligas têm diferentes aplicações na sociedade moderna devido as excelentes propriedades elétricas, condutividade térmica, resistência à corrosão dentre outras propriedades. Estas aplicações podem ser em válvulas, tubulações, panelas para absorção de energia solar, radiadores para automóveis, condutores de corrente e eletrônico, elementos de termostatos e partes estruturais de reatores nucleares, como, por exemplo, bobinas para campo toroidal para um reator de fusão nuclear. Dentre as ligas utilizadas em reatores nucleares, podemos destacar Cu-Be, Cu-Sn e Cu-Pt. O Ni e o Co, freqüentemente são adicionados às ligas de Cu para que a solubilidade seja deslocada para temperaturas mais elevadas com relação aos sistemas binários de Cu-Sn e Cu-Pt. A adição de Ni-Pt ou Ni-Sn ao Cu em porcentagens iguais ou inferiores a 1,5 % aliado a tratamentos termos-mecânico alteram as propriedades do Cu. Estudamos neste trabalho sete diferentes ligas: três ligas de Cu-Ni-Pt 1 (97,99 % Cu - 1,55 % Ni - 0,46 % Pt), 2 (99,33 % Cu - 0,23 % Ni -0,43 % Pt) 3 (98,01 % Cu - 0,48 % Ni - 1,51 % Pt); três ligas de Cu-Ni-Sn 4 (98,31% Cu - 1,12 % Ni - 0,58 % Sn), 5 (98,79 % Cu – 0,57 % Ni - 0,65 % Sn), 6 (98,39% Cu – 0,46 % Ni – 1,16 % Sn) e Cu eletrolítico 0 (0,0058 % Pb - 0,0007 % Fe - 0,0036 % Ni - 0,0024 % Ag). As referentes ligas foram desenvolvidas a partir de um forno a arco voltaico e passaram por tratamentos termo-mecânicos pré-determinados. As microestruturas foram analisadas diretamente por microscopia óptica e microscopia eletrônica de varredura / EDS e indiretamente por medidas de dureza Vickers e condutividade elétrica. O objetivo deste trabalho, portanto, foi observar e constatar os efeitos da mudança da microestrutura em relação às propriedades dureza e condutividade elétrica. / The Cu and its alloys have different applications in the owed modern society the excellent electric properties, thermal conductivity, resistance to the corrosion and other properties. These applications can be in valves, pipes, pots for absorption of solar energy, radiators for automobiles, current driver, electronic driver, thermostats elements and structural parts of nuclear reactors, as, for example, reels for field toroidal for a reactor of nuclear coalition. The alloys used in nuclear reactors, we can highlight Cu-Be, Cu-Sn and Cu-Pt. Ni and Co frequently are added to the Cu alloys so that the solubility is moved for temperatures more elevated with relationship to the binary systems of Cu-Sn and Cu-Pt. The addition of Ni-Pt or Ni-Sn to the Cu in the same or inferior percentages to 1,5% plus thermomechanical treatments changes the properties of the copper. We studied the electric conductivity and hardness Vickers of the Cu-Ni-Pt and Cu-Ni-Sn and compared with the electrolytic Cu. In the proposed flowcharts, breaking of the obtaining of the ingot, we proceeded with thermo mechanical treatments.

Page generated in 0.0885 seconds