• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 334
  • 16
  • 9
  • 9
  • 9
  • 9
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 359
  • 248
  • 94
  • 80
  • 69
  • 56
  • 54
  • 54
  • 51
  • 51
  • 50
  • 44
  • 43
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Cimentação de laminados cerâmicos : efeito de diferentes modos de fotoativação na estabilidade de cor e nas propriedades mecânicas de sistemas adesivos e cimentos resinosos /

Sahyon, Henrico Badaoui Strazzi. January 2017 (has links)
Orientador: Paulo Henrique dos Santos / Banca: Wirley Gonçalves Assunção / Banca: Anderson Catelan / Resumo: O objetivo deste estudo in vitro foi avaliar os efeitos de diferentes modos de fotoativação na nanodureza e módulo de elasticidade de sistemas adesivos e cimentos resinosos, assim como o efeito na estabilidade de cor de laminados cerâmicos. Os fatores em estudos foram: dois níveis de fotopolimerizadores (VALO - Ultradent; Radii-Cal - SDI) e três níveis de modo de ativação (sem polimerização prévia do sistema adesivo na superfície dental e no interior do laminado cerâmico; polimerização prévia do sistema adesivo somente na superfície dental; e polimerização prévia do sistema adesivo na superfície dental e no interior do laminado cerâmico). Na análise da estabilidade de cor o terceiro fator estudado foi o tempo de envelhecimento (252, 504 e 756 horas). Foram confeccionados 132 blocos de cerâmica (7x8x0,6mm) de dissilicato de lítio (IPS e-max CAD), os quais foram cimentados sobre o esmalte dentário dos dentes bovinos, distribuídos em 12 grupos de acordo com os materiais restauradores e métodos de procedimentos utilizados. Dois sistemas adesivos e cimentos resinosos foram utilizados (Single Bond Universal/RelyX Veneer- 3M/ESPE e Tetric N Bond/Variolink Veneer - Ivoclar Vivadent). As propriedades mecânicas de nanodureza e módulo de elasticidade foram mensuradas utilizando nanodurômetro (Anton Paar), sob ação de carga de 1000μN (n=3). A estabilidade de cor foi mensurada através do espectrofotômetro de reflexão ultravioleta visível UV-2450 (Shimadzu) antes e após a submissão das amo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this in vitro study was to evaluate the effects of different modes of photoactivation in the nanohardness and elastic modulus of resin cements and adhesives, as well as the effect on the color stability of ceramic laminates. The factors of the studies were: two levels of light curing units (VALO - Ultradent; Radii-Cal - SDI) and three modes of photoactivation (without prior curing of the adhesive system in the tooth surface and inside of the ceramic laminate, prior curing the adhesive system only in the tooth surface, and prior curing of the adhesive system in the tooth surface and within the ceramic laminate). In the analysis of color stability the third factor of the study was the aging time (252, 504 and 756 hours). One hundred and thirty two ceramic blocks (7x8x0.6mm) of lithium dissilicate (IPS e-max CAD) were made, which were cemented on the enamel of bovine teeth, and distributed into 12 groups according to the restorative materials (Single Bond Universal/RelyX Veneer - 3M/ESPE and Excite DSC/Variolink Veneer - Ivoclar Vivadent) and methods of procedures. The mechanical properties of nanohardness and elastic modulus were measured using a nanohardness tester (Anton Paar) under loaf of 1000 μN (n=3). Color stability was measured using a UV-2450 visible UV spectrophotometer (Shimadzu) before and after the submission of the UVB artificial accelerated aging samples (n=8). Data of color stability and mechanical properties were submitted to statistical testes o... (Complete abstract click electronic access below) / Mestre
102

Caracterização microestrutural e análise eletroquímica do revestimento de WC-10Co-4Cr, aspergido termicamente por HVOF, em aço inoxidável martensítico /

Diniz, Celso. January 2018 (has links)
Orientador: Elson de Campos / Coorientador: Rogério Pinto Mota / Banca: Roberto Zenhei Nakazato / Banca: José Roberto Ribeiro Bortoleto / Resumo: Aços inoxidáveis martensíticos, contendo 12-13% de cromo, 2-5% de níquel e menos de 0,06% de carbono, vem sendo utilizados desde a década de 60, por exemplo, na fabricação de equipamentos hidráulicos, tais como turbinas, bombas e propulsores. Aços como o ASTM A743 CA-6NM, temperados e revenidos, passam por processos de tratamento de superfície, visando aumentar a resistência à erosão e corrosão, pois devem, operar sob condições de alta agressividade. Dentre as técnicas utilizadas para revestimento de superfície, a aspersão térmica, HVOF (Hight Velocity Oxigen Fuel), é um processo altamente utilizado, por sua viabilidade técnica e econômica. Atualmente, o aço ASTM A743 CA-6NM com revestimento do tipo WC-10Co-4Cr, com espessura em torno de 100 e 200 µm, é o material mais empregado nos diversos equipamentos hidráulicos, tais como: rotores de bombas, pás de turbinas e hélices navais. O conhecimento das características microestruturais do revestimento e de seu comportamento com relação à corrosão são de grande importância na definição dos parâmetros para a realização da aspersão térmica, gerando economia e qualidade do revestimento. Neste trabalho são realizadas análises por microscopia óptica e microscopia eletrônica de varredura com EDS sobre os revestimento aspergido com WC-10Co-4Cr, visando estudar os parâmetros relacionados à porosidade e composição da microestrutura. Além disso, foram realizadas análises da dureza, ao longo de todo o revestimento, visando estabelecer correla... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Martensitic stainless steels, containing 12-13% chromium, 2-5% nickel and less than 0.06% carbon, have been used since the 1960s, for example, in the manufacture of hydraulic equipment such as turbines, pumps and propellers. The steels ASTM A 743 CA-6NM, in quenched and tempered conditions, undergo surface treatment processes to increase resistance to erosion and corrosion, once they do operate under conditions of high aggressiveness. Among techniques used for surface coating, thermal spraying, HVOF (Hight Velocity Oxigen Fuel), is a highly utilized process, due to its technical and economical viability. Currently, ASTM A743 CA-6NM steel with WC-10Co-4Cr type coating, with a thickness of 100 µm and 200 µm, is the most used material in the various pieces of equipment, such as: pump rotors, naval blades and propellers. The knowledge of the microstructural characteristics of the coating and its behavior in relation to corrosion are of great importance, in the definition of the parameters for the realization of the thermal spray, generating economy and quality of the coating. In this paper, optical microscopy and scanning electron microscopy with EDS, on WC-10Co-4Cr sputtering coatings were carried out to study the parameters related to the porosity and microstructure composition. In addition, hardness analyses were performed throughout the coating, to establish correlation with microscopic analysis and electrochemical analysis in order to understand the behavior of the coating in saline solution NaCl 3.5% (wt/wt); all images acquired, passed by digital processing images. The results showed that the coatings obtained with 6 passes (W6) or 8 passes (W8) presented low porosity, less than 2%, and the pores measured in the W6 coating presented smaller Feret diameter and greater circularity. Dilution analysis ... (Complete abstract click electronic access below) / Mestre
103

Influência da incorporação de nanopartículas de trimetafosfato de sódio associado ou não à clorexidina nas propriedades microbiológicas, físico-mecânicas e de redução da desmineralização de cimento de ionômero de vidro /

Silva, Márjully Eduardo Rodrigues da. January 2015 (has links)
Orientador: Cristiane Duque / Coorientador: Alberto Carlos Botazzo Delbem / Banca: Denise Pedrini / Banca: Thiago Cruvinel da Silva / Resumo: O objetivo deste estudo foi avaliar a influência da incorporação de nanopartículas de trimetrafosfato de sódio (TMP) e clorexidina (CHX) nas propriedades microbiológicas, físico-mecânicas e na capacidade de redução da desmineralização de um cimento de ionômero de vidro modificado por resina (CIV) indicado para restauração. Inicialmente, foram determinados nove grupos de estudo: 1) CIV; 2) CIV + CHX 1,25%; 3) CIV + CHX 2,5%; 4) CIV + TMP 7%; 5) CIV+ CHX 1,25% + TMP 7%; 6) CIV + CHX 2,5% + TMP 7%; 7) CIV+ TMP 14%; 8) CIV + CHX 1,25% + TMP 14%; 9) CIV + CHX 2,5% + TMP 14%. Para determinar a atividade antimicrobiana desses CIV contendo ou não TMP e CHX foi realizado o teste de difusão em ágar com Streptococcus mutans, Lactobacillus acidophilus, Actinomyces israelii e Candida albicans. Após 24h, os halos de inibição obtidos pelos CIV foram mensurados com o auxílio de um paquímetro digital. Corpos-de-prova dos CIV foram confeccionados utilizando matrizes específicas e avaliadas as seguintes propriedades físico-mecânicas para cada grupo de materiais do estudo: resistência à compressão e à tração diametral e dureza de superfície, além de determinar a liberação total de fluoreto (F) e de TMP. Foram preparados 80 blocos a partir de incisivos bovinos e selecionados pelo teste de dureza de superfície do esmalte (DS1). Os corpos-de-prova dos CIV foram adaptados aos blocos de esmalte recém-preparados e submetidos às ciclagens de pH. A seguir, foi analisada a dureza de superfície final do esmalte (DS2) para o cálculo da porcentagem da perda de dureza de superfície (%PDS) e verificar a capacidade do material em reduzir a desmineralização. Os dados foram submetidos aos testes de ANOVA e Bonferroni ou Student-Newman-Keuls, considerando p≤0,05. Os resultados mostraram que a adição... / Abstract: The aim of this study was to evaluate the influence of the association of sodium trimetaphosphate nanoparticles (TMP) and chlorhexidine (CHX) on the microbiological, physical-mechanical and enamel demineralization reduction of glass ionomer cement (GIC). Initially, nine groups of the study were defined: 1) control - GIC Fuji LII; 2) GIC+ 1.25% CHX; 3) GIC + 2.5% CHX; 4) GIC + 7%TMP; 5) GIC+ 1.25% CHX + 7%TMP; 6) GIC + 2.5% CHX + 7%TMP; 7) GIC+ 14%TMP; 8) GIC + 1.25% CHX + 14%TMP; 9) GIC+ 2.5% CHX + 14% TMP. The antimicrobial activity of GIC containing or not CHX/TMP was determined by agar diffusion test against Streptococcus mutans, Lactobacillus acidophilus, Actinomyces israelii and Candida albicans. After 24h, the inhibition zones obtained by the GIC were measured with a digital caliper. GIC specimens were prepared using specific stainless steel molds in order to evaluate the following physical-mechanical properties for each material group: compressive and diametral tensile strength and superficial hardness, besides to determine total fluoride and TMP release. Eighty enamel blocks were prepared from extracted bovine incisors and selected through the initial surface hardness test (SH1). GIC specimens were adjusted to the enamel blocks and submitted to pH-cyclings. After that, final superficial hardness (SH2) was determined in order to obtain the percentage of superficial hardness loss (%SHL) and observe the capacity of the materials in reducing enamel demineralization. Data were submitted to ANOVA and Bonferroni or Student-Newman-Keuls statistical tests, considering p≤0.05. The results showed that the addition of chlorhexidine increased the antimicrobial activity of GIC for all groups. The physical-mechanical properties of GIC, especially compressive strength, were jeopardized by the association... / Mestre
104

Desenvolvimento de protocolo in vitro do processo erosivo do esmalte e efeito de enxaguatório bucal fluoretado associados ao trimetafosfato nanoparticulado contra a erosão /

Mancilla, Jorge Orlando Francisco Cuéllar. January 2018 (has links)
Orientador: Alberto Carlos Botazzo Delbem / Banca: Robson Frederico Cunha / Banca: Juliano Pelim Pessan / Banca: Paulo Edelvar Correa Peres / Banca: Daniela Rios Honório / Resumo: O objetivo do presente estudo foi avaliar o efeito de enxaguatórios bucais fluoretados, suplementados ou não com trimetafosfato de sódio (TMP) micrométrico ou nanoparticulado, sobre a erosão do esmalte dental, utilizando uma boca artificial. Material e Métodos: 120 blocos de esmalte bovino foram aleatoriamente distribuídos em 5 grupos, de acordo com os seguintes enxaguatórios: Placebo (sem flúor ou TMP), 100 ppm F, 225 ppm F, 100 ppm F + 0,2% TMP microparticulado e 100 ppm F + 0,2% de TMP nanoparticulado. Os blocos foram subdivididos em 2 condições de experimento (1 ou 3 dias). Cada ciclo erosivo consistiu de 7 exposições a ácido cítrico ( a cada 4 s), alternadas com 6 exposições a saliva artificial (a cada 7 s), três vezes ao dia. O tratamento com os enxaguatórios bucais foi realizado após o primeiro e último ciclo erosivo de cada dia, durante 1 min. Os blocos foram analisados por perfilometria, dureza de superfície e em secção longitudinal, bem como por energia livre de superfície (Ys). Os dados foram analisados por ANOVA a 2 critérios, teste de Student-Newman-Keuls e coeficiente de correlação de Pearson (p<0,05). Resultados: De forma geral, um efeito protetor significativamente maior foi observado para os enxaguatórios bucais contendo TMP em relação à dureza e ao desgaste do esmalte, com um efeito adicional para o uso de nanopartículas. Houve uma moderada correlação entre a dureza de superfície e em secção longitudinal (r = -0,533; p<0,001). Em acréscimo, uma redução da Ys... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study was to evaluate the effect of fluoride mouthrinses, supplemented or not with sodium trimetaphosphate (TMP), on the dental erosion of the enamel using an artificial mouth. Material and Methods: 120 blocks of bovine enamel were randomly distributed in 5 groups according to the following mouthrinses: Placebo (without fluoride or TMP), 100 ppm F, 225 ppm F, 100 ppm F + 0.2% TMP micrometric and 100 ppm F + 0.2% nanosized TMP. The blocks were subdivided into 2 experimental treatments (1 or 3 days). Each erosive cycle consisted of 7 exposures to citric acid (each 4 s), alternated with 6 exposures to artificial saliva (each 7 s), three times a day. Treatment with mouthrinses was performed after the first and last erosive cycle of each day for 1 min. The blocks were analyzed by profilometry method, surface hardness and longitudinal section analyses, as well as surface free energy (Ys). Data were analyzed by two way ANOVA, Student-Newman-Keuls test and Pearson's correlation coefficient (p <0.05). Results: In general, a significantly greater protective effect was observed for mouthrinses containing TMP in relation to the hardness and wear of the enamel, with an additional effect for the use of nanoparticles. There was a moderate correlation between surface hardness and longitudinal section (r = -0.533; p <0.001). In addition, a reduction of s and its apolar component (YsLW) and electron donor sites (γ¯) were observed in the groups treated with TMP containin... (Complete abstract click electronic access below) / Doutor
105

PROPRIEDADES MECÂNICAS E TRIBOLÓGICAS DE AÇO AUSTENÍTICO 304 SUBMETIDO À NITRETAÇÃO POR: IMPLANTAÇÃO IÔNICA E IMPLANTAÇÃO IÔNICA POR IMERSÃO EM PLASMA.

Zaika, Andressa Cristiane 18 December 2007 (has links)
Made available in DSpace on 2017-07-21T19:25:47Z (GMT). No. of bitstreams: 1 andressazaira.pdf: 15299866 bytes, checksum: 0fe7595bdb6a2a4be4f06497f1f57ad1 (MD5) Previous issue date: 2007-12-18 / The aim of this work is to characterize the mechanical and tribological properties of AISI 304 austenitic stainless steel submitted to N+ ion implantation and Nitrogen plasma immersion ion implantation (PI3). The ion implantation conditions were to obtain a plateau distribution of N íons in atomic concentrations of up to 27. The PI3 nitretation were performed at temperatures up to 400ºC for 4 h. The samples were characterized by q-2q X-ray diffraction in Bragg-Bretano condition, scanning electron microscopy, X-ray energy dispersive spectroscopy and optical microscopy. The hardness and elastic modulus were obtain by using the nanoindentation technique. The tribological properties were measured by a linear reciprocating tribometer, with spheres of 100Cr6 and WC(Co), with loads up to 12 N. The results compare the mechanical properties of ion implanted samples with those submitted to PI3. The hardness of the highest ion implanted dose (27) is equivalent to the sample nitrided by PI3 at 387C for 4 hs. The wear rate of the ion implanted samples increases with dose. For the PI3 samples, the wear rate decreases with increasing time and temperature of the nitriding process. / Este trabalho tem por objetivo a caracterização de propriedades mecânicas e tribológicas de amostras de aço inoxidável austenitico 304 quando submetido a implantação iônica com nitrogênio e a implantação iônica por imersão em plasma. As amostras foram implantadas ionicamente por N+ em concentrações atômicas de 1 a 27, em um perfil de platô com profundidade aproximada de 200 nm. As amostras foram nitretadas também por imersão em plasma em temperaturas de até 400 e tempos de até 4 hs.As técnicas utilizadas para caracterizar as superfícies modificadas durante este trabalho foram a difração de Raios-X, microscopia eletrônica de varredura, espectroscopia de raios-X por energia dispersiva e microscopia ótica. As medidas de dureza e módulo de elasticidade foram obtidas através de técnica de indentação instrumentada. O coeficiente de atrito foi determinado utilizando um tribômetro linear recíproco, com esferas de 100Cr6 e de WC(Co), com trilhas de 1 ou 2 mm de meia amplitude, deslocamentos variados e também diversas cargas. Os resultados são comparativos entre as amostras implantadas com nitrogênio e as amostras submetidas a 3IP. Observa-se que a maior dose de implantação iônica de nitrogênio equivale em temos de dureza à nitretação por 3IP em 387°C durante 4 horas. Já, a taxa de desgaste das amostras implantadas aumenta com a dose de implantação enquanto que para as amostras nitretadas por 3IP, a taxa de desgaste diminui com o aumento do tempo e da temperatura de nitretação.
106

AVALIAÇÃO DA CAPACIDADE DE POLIMERIZAÇÃO E ELEVAÇÃO DE TEMPERATURA PRODUZIDA POR APARELHOS FOTOPOLIMERIZADORES / Curing efficiency and temperature increasement produced by photo-activation devices

Godoy, Eloisa de Paula 26 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:09Z (GMT). No. of bitstreams: 1 EloisaPaula.pdf: 3565954 bytes, checksum: a85195d4f7c3955efe156f512ceaeccf (MD5) Previous issue date: 2008-02-26 / This study evaluated the curing efficiency and the temperature increasement produced by curing units during the photo-activation of the composite, Filtek™Z250 (3M ESPE) and Filtek™Z350 (3M ESPE). At the same time, the emission spectrum and power of the curing units were tested using the spectrometer USB2000 (Ocean Optics) and the Power Meter (Ophir). The light intensity was determined by the reason between power and active top light area of each unit. The curing units used were a halogen lamp Optilux 401 (Demetron) and three light emitting diode devices (LED), LEDemetron I (Kerr), Bluephase (Ivoclar Vivadent) and Elipar Freelight (3M ESPE), with light intensity of 661 mW/cm2, 627 mW/cm2, 1229 mW/cm2 and 330 mW/cm2, respectively. The curing efficiency was evaluated by Vickers hardness, determined on bottom surface the specimens prepared in steal mold, which it was filled with the selected composite, and stored during a period of 24 hours. Using a thermocouple type-K, placed under a dentin disk with 0,5 mm thickness, it was observed The temperature increasement produced by the four devices was measured during the photo-activation of the adhesive system and of an increment of 2 mm of thickness of composite, which were activated for 20 and 40 seconds, respectively. The results of Vickers hardness and of temperature increasement were submitted to the statistical analysis ANOVA 2 way and post test Bonferroni with 5% significance. For the composite Filtek™Z250 (3M ESPE) the four units curing devices assessed did not present statistical differences in the superficial hardness. For the composite Filtek™Z350 (3M ESPE), the unit curing Elipar Freelight (3M ESPE) produced statistical lower hardness (p < 0,05), whereas it has not statistical differences in hardness among the units curing devices. The composite Filtek™Z250 (3M ESPE) presented higher hardness than resin Filtek™Z350 (3M ESPE) (p <0,05). The unit curing light emitting diode Bluephase (Ivoclar Vivadent) and the unit curing of halogen lamp Optilux 401 (Demetron) emitted the same temperature increasement statistically, reaching (17,6°C), duri ng the photo-activation of the adhesive system. The lower value of temperature increase was registered for the unit curing Elipar Freelight (3M ESPE) in the adhesive system (7,2°C) (p < 0,001) and in the composite (3,1°C) (p < 0,05). Statistically, th e temperature increasement registered during the activation of the composite was lower than the temperature increasement registered during the activation in the adhesive system (p < 0,001). / Este estudo avaliou a capacidade de polimerização e a elevação de temperatura produzida por aparelhos fotopolimerizadores na polimerização das resinas compostas, Filtek™Z250 (3M ESPE) e Filtek™Z350 (3M ESPE). Paralelamente foi determinado o comprimento de onda e a potência dos aparelhos, utilizando-se um espectrômentro USB2000 (Ocean Optics) e um Power Meter (Ophir). A intensidade de luz foi obtida pela razão entre potência e área da ponta ativa de cada aparelho. Foram testados um aparelho fotopolimerizador de lâmpada halógena Optilux 401 (Demetron) e três aparelhos à base de LEDs: LEDemetron I (Kerr), Bluephase (Ivoclar Vivadent) e Elipar Freelight (3M ESPE), que apresentaram intensidades de luz de 661 mW/cm2, 627 mW/cm2, 1229 mW/cm2 e 330 mW/cm2, respectivamente. A capacidade de polimerização foi registrada através do teste de microdureza Vickers, avaliando a superfície de base de corpos-de-prova confeccionados em matrizes metálicas, nas quais foram inseridas as resinas compostas selecionadas, e armazenados durante 24 horas. Utilizando-se de um termopar tipo-K, posicionado sob um disco de dentina de 0,5 mm de espessura verificou-se a elevação de temperatura produzida pelos 4 aparelhos durante a fotopolimerização do sistema adesivo e de um incremento de 2 mm de espessura de resina composta, fotopolimerizados por 20 e 40 segundos, respectivamente. Os resultados de microdureza superficial e de elevação de temperatura foram submetidos à análise estatística ANOVA 2 critérios e pós teste de Bonferroni com 5% de significância. Para a resina composta Filtek™Z250 (3M ESPE), os quatro aparelhos avaliados não apresentaram diferenças estatísticas na microdureza superficial. Para a resina composta Filtek™Z350 (3M ESPE), o aparelho Elipar Freelight (3M ESPE) apresentou os menores valores de microdureza superficial (p<0,05), não havendo diferença estatística entre os demais aparelhos. A resina composta Filtek™Z250 (3M ESPE) apresentou maiores valores de microdureza Vickers do que a resina Filtek™Z350 (3M ESPE) (p<0,05). O aparelho à base de LED Bluephase (Ivoclar Vivadent) emitiu estatisticamente a mesma elevação de temperatura que o aparelho de lâmpada halógena Optilux 401 (Demetron) (17,6°C) durante a polimerização do sistema adesivo. O menor valor de elevação de temperatura foi registrado para o aparelho Elipar Freelight (3M ESPE), tanto no sistema adesivo (7,2°C) (p<0,001) como na resina composta (3,1°C) (p<0,05). As elevaç ões de temperatura registradas durante a polimerização das resinas compostas foram estatisticamente menores que as elevações de temperatura registradas durante a polimerização no sistema adesivo (p<0,001).
107

Análise da estabilidade de cor e microdureza de uma resina composta extraclara fotoativada com diferentes fontes de luz

Souza, Julianna Cristina de 20 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:10Z (GMT). No. of bitstreams: 1 Julianna Cristiana de Souza.pdf: 923524 bytes, checksum: a0504c08fbd282509bf0da8d63b96e96 (MD5) Previous issue date: 2006-02-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O propósito deste estudo foi avaliar; através da aceleração de envelhecimento; a estabilidade de cor intrínseca e a microdureza Vickers da resina composta Charisma – (Heraeus-Kulzer) nas cores A2 e SL em relação à fonte de luz utilizada. Foram confeccionados 60 corpos-de-prova com 17mm de diâmetro e 1mm de espessura com auxílio de matrizes metálicas; divididos em 4 grupos: grupo 1- cor A2/ luz halógena ; grupo 2- cor SL/ luz halógena; grupo 3- cor A2/ aparelho à base de LEDs e grupo 4- cor SL/ aparelho à base de LEDs . Os espécimes foram submetidos à imersão em água deionizada a 60°C (30 dias) armazenados ao abrigo da luz. Realizaram-se duas leituras de cor uma inicial; 24 hs após a confecção dos corpos-de-prova; e uma final ao término do período experimental; após 30 dias. Utilizou-se espectrofotometria de reflectância (Espectrofotômetro Cary-Varian 100) com espectro entre 360 e 720 nm; espaço de cor CIE-Lab para a análise da alteraçào de cor. Na seqüência os corpos-de-prova foram submetidos ao teste de microdureza Vickers através do microdurômetro MMT-3 digital HMV-Shimadzu. A variável dependente microdureza foi avaliada pelo teste de Análise de Variância (ANOVA) a dois critérios; tendo como variáveis independentes: fonte de luz (halógena ou LEDs) e cor (A2 ou SL). Quando houve diferença entre os grupos pelo teste de ANOVA; o teste de Tukey foi utilizado para verificar entre quais grupos houve diferença. Para a alteração de cor; os resultados mostraram que não houve diferença estatística significativa entre os grupos estudados. No entanto; para o teste de microdureza houve diferença estatística significante para o grupo 2; apresentando os maiores valores. Concluiu-se que: o aparelho à base de LEDs utilizado neste experimento foi eficiente em proporcionar estabilidade de cor intrínseca da resina composta testada; o aparelho de lâmpada halógena proporcionou os maiores resultados de microdureza Vickers; e a cor SL apresentou melhores estabilidade de cor e microdureza quando comparada a cor A2; mesmo a maior alteração de cor encontrada neste estudo está dentro dos valores aceitáveis clinicamente.
108

INFLUÊNCIA DE DIFERENTES TRANSLUCIDEZ DAS CERÂMICAS SOBRE O GRAU DE CONVERSÃO E MICRODUREZA DE UM CIMENTO RESINOSO DUAL / Influence of different ceramic translucency on the degree of conversion and microhardness of dual resin cement

Sakamoto Junior, Antonio Setsuo 24 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:20Z (GMT). No. of bitstreams: 1 Antonio S Sakamoto Jr.pdf: 1530054 bytes, checksum: 0cc1d22fb0f1bb5e13c6f006184f113e (MD5) Previous issue date: 2012-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The proposition of this study was to evaluate the influence of different ceramic translucency on the degree of conversion and Knoop microhardness of dual resin cement. It was made 150 samples of the resin cement dual cured Variolink II (shade A3; 5 mm in diameter and 1 mm thick) were created with interposing ceramic discs with 8 mm in diameter and 1.5 mm thick varying translucency (IPS e.max HT, HO, ZirPress HT and IPS d.SIGN). The control group was created without the interposition of ceramics. The experimental groups were photoactivated in three different times: 20, 40 and 60 seconds. 75 specimens were measured by Fourier transformed infrared spectroscopy (FTIR) to assess the degree of conversion (%). Another 75 specimens were used for the microhardness test, previously they were ground under water irrigation with grit silicon carbide granulation 320, 400, 600, 1000, 1200, finishing them with felt cloth and diamond paste with grain 1 and ¼ micrometers. Each sample was divided into four quadrants and conducted an indentation in each quadrant and then was calculated the average of these indentations. The values of the degree of conversion and Knoop hardness were analized by two-way ANOVA (type of ceramic and time of photoactivation), Bonferroni’s multiple comparison tests with a significance level of 5% and the Spearman correlation. The degree of conversion values of ceramic with high translucency were similar to the control group, the HO group presented the lowest conversion values, however when the curing time has tripled from 20 to 60 seconds, the values increased 63.9%. Translucent ceramic without infrastructure (IPS d.SIGN) presented higher microhardness values than ceramics with lithium disilicate infrastructure-based (e.max HT and HO). The negative effects of increased opacity of the ceramic on the dual resin cement can be avoided with increased time of photoactivation. / A proposição deste trabalho foi avaliar a influência de cerâmicas de diferentes translucidez sobre o grau de conversão (GC) e microdureza Knoop de um cimento resinoso dual. Foram confeccionados 150 corpos de prova do cimento resinoso dual Variolink II (cor A3; 5 mm de diâmetro e 1 mm de espessura) interpondo discos cerâmicos com 8 mm de diâmetro e 1,5 mm de espessura variando-se a translucidez da cerâmica (IPS e.max HT, HO, ZirPress HT e IPS d.SIGN). O grupo controle foi confeccionado sem interposição da cerâmica. Os grupos experimentais foram fotoativados em 3 diferentes tempos: 20, 40 e 60 segundos. Para o grau de conversão (%) foram utilizados 75 corpos de provas, onde foram mensurados através da Espectroscopia por infra vermelho por transformação de Fourier (FTIR). Para o teste de microdureza foram usados 75 corpos de prova, onde estes foram lixados sob irrigação de água com lixas de carbeto de silício de granulação 320, 400, 600, 1000, 1200, finalizando-os com pano de feltro e pasta diamantada com granulação de 1 e ¼ μm. Cada corpo de prova foi divido em 4 quadrantes erealizado uma indentação em cada quadrante e em seguida foi calculado a média destas indentações. Os valores do grau de conversão e de microdureza Knoop foram submetidos à análise de variância de dois fatores (tipo de cerâmica e tempo), pós-teste de Bonferroni com nível de significância de 5% e à correlação de Spearman. Os valores de GC para as cerâmicas de alta translucidez foram semelhantes ao grupo controle, o grupo HO apresentaram os menores valores de GC, porém obteve um aumento de 63,9% quando o tempo de fotoativação foi triplicado de 20 para 60 segundos. Já os valores de microdureza superficial foram maiores para as cerâmicas com maior translucidez sem infraestrutura (IPS d.SIGN), as cerâmicas com infraestrutura à base de dissilicato de lítio (e.max HT e HO). Os efeitos negativos da maior opacidade da cerâmica sobre o cimento resinoso dual podem ser evitados com aumento no tempo de fotoativação.
109

Avaliação da microdureza superficial de resinas compostas extraclaras fotopolimerizadas por luz halógenas e LEDs. descrição das caracteristícas dos aparelhos fotopomerizadores

Cotrina, Leyla Antoinette Delgado 23 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:27Z (GMT). No. of bitstreams: 1 Leyla Antoinette Delgado Cotrina.pdf: 1205647 bytes, checksum: 64a5a6bbc08abd8e9aef28e74483da56 (MD5) Previous issue date: 2004-07-23 / DELGADO, L. Evaluation of the superficial microhardness of extra-light composite resins photocured by Halogen Light and LEDs. Description the characteristics of the light sources. Ponta Grossa, 2004. 129 Dissertação (Mestrado em Clínica Integrada) – Faculdade de Odontologia, Universidade Estadual de Ponta Grossa. The purpose of this study was to evaluate the superficial microhardness of four extralight microhibrid composite resins photocured with different types of light curing units: Halogen and LEDs. The emission spectrum (nm) and power (mW) of the curing units were tested using the spectrometer USB2000 (Ocean Optics) and the Power Meter (Ophir). The light intensity (mW/cm2) was determined through the value of power and area the light guide of each unit (i=P/A). The resins and colors used were: Tetric® Ceram (Ivoclar Vivadent) A2 and XL; FiltekTM Z250 (3M-ESPE) A2 and B0.5; Charisma® (Heraeus Kulzer) A2 and SL; and Esthet X (Dentsply) A2 and XL. The curing units used were: Curing Light 2500 (3M-ESPE) and Elipar® FreeLight (3MESPE). Metallic matrixes were made with a hole of 5mm diameter and 2 mm thick. Samples of the resins were made on these matrixes and were marked and storaged in dry, dark jars for 24 hours. After this, the samples were evaluated using Vickers microhardness test through the digital microhardmeter MMT-3 (Buehler) with 50 gf charge for 30 seconds. Data collected was analyzed with a mutlifactorial variance and Tukey tests. T-test was used on paired samples to determine significant difference between surfaces. Also was calculated the percentage of depth of cure. Results showed that the emission spectrum of the LED curing unit was more reduced than the halogen curing unit (430–520nm and 400-520nm respectively). Nevertheless, the halogen curing unit presented a greater power and intensity of light. The factors analyzed (type of resin, color and light source) influenced the microhardness values. It was found that the extra-light color resins presented the least values of microhardness independent to the light source. The LEDs curing units presented the least values of superficial microhardness. The Tetric® Ceram XL resin composite showed percentage of depth of cure less 80%, independent to the light source. The same occurred with A2 and XL colors the Charisma® resin composite when cured with LEDs unit. / DELGADO, L. Avaliação da microdureza superficial de resinas compostas extraclaras fotopolimerizadas por luz halógena e LEDs. Descrição das características dos aparelhos fotopolimerizadores. Ponta Grossa, 2004. 129. Dissertação (Mestrado em Clínica Integrada) – Faculdade de Odontologia, Universidade Estadual de Ponta Grossa. O objetivo deste trabalho foi avaliar a microdureza superficial de quatro resinas compostas microhíbridas de cor extraclara quando fotopolimerizadas com duas fontes de luz: halógena e LEDs. Paralelamente determinou-se o espectro de emissão (nm) e a potência (W) dos aparelhos testados através do espectrômetro USB2000 (Ocean Optics) e o Power Meter (Ophir) respectivamente. A intensidade de luz (mW/cm2) foi calculada através do valor da potência e da área da ponta ativa de cada aparelho (i=P/A). As resinas compostas utilizadas foram: Tetric® Ceram (Ivoclar Vivadent) A2 e XL, FiltekTM Z250 (3M-ESPE) A2 e B0.5, Charisma® (Heraeus Kulzer) A2 e SL e Esthet X (Dentsply) A2 e XL. Os aparelhos utilizados foram o aparelho Curing Light 2500 (3M-ESPE) e Elipar® FreeLight (3M-ESPE). Para a confecção dos corpos-de-prova foram utilizadas matrizes metálicas que com orifício central de 5 mm de diâmetro por 2 mm de espessura. Os corpos-de-prova foram identificados e armazenados em recipientes secos e ao abrigo da luz durante 24 horas. Passado este tempo, foram submetidos ao teste de microdureza Vickers através do microdurômetro digital MMT-3 (Buehler) com carga de 50 gf durante 30 segundos. Os valores de microdureza foram analisados através da análise de variância multifatorial e teste de Tukey. O teste t para amostras pareadas foi utilizado para determinar diferenças entre as superfícies. Também foi calculada a porcentagem de profundidade de polimerização. Os resultados evidenciaram que o espectro de emissão do aparelho à base de LEDs é mais estreito do que do aparelho de luz halógena, sendo que este último apresentou maior potência e maior intensidade de luz. Os fatores analisados (resina composta, cor e fonte de luz) influenciaram nos valores de microdureza. Concluiu-se que a cor extraclara obteve os menores valores de microdureza independentemente do tipo de fonte de luz utilizada e o aparelho à base de LEDs proporcionou os valores mais baixos de microdureza superficial. A resina composta Tetric® Ceram cor XL atingiu porcentagem de polimerização inferior a 80%, independentemente do tipo de fonte utilizada. As cores A2 e XL da resina composta Charisma® não obtiveram porcentagens de profundidade de polimerização acima de 80% quando fotopolimerizada com o aparelho à base de LEDs.
110

Avaliação do grau de conversão, dureza e módulo de elasticidade de resinas compostas Bulk Fill / Evaluation of the degree of conversion, hardness and elastic modulus of composite resins Bulk Fill

Arias, Evelyn Patricia Santos 24 April 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-09-06T21:57:41Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) EVELYN PATRICIA SANTOS ARIAS.pdf: 1455330 bytes, checksum: 8883f664c636c5ec3e0625c691880784 (MD5) / Made available in DSpace on 2018-09-06T21:57:41Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) EVELYN PATRICIA SANTOS ARIAS.pdf: 1455330 bytes, checksum: 8883f664c636c5ec3e0625c691880784 (MD5) Previous issue date: 2018-04-24 / O objetivo deste estudo foi avaliar o grau de conversão, dureza e o módulo de elasticidade de três resinas Bulk Fill e duas resinas convencionais. Foram testadas as resinas Bulk Fill: Filtek™ Bulk Fill (FBP), Tetric N-Ceram Bulk Fill (TBF), Filtek™ Bulk Fill Flow (FBF); e adicionalmente duas resinas compostas convencionais: Empress Direct (ED) e Filtek™ Z350XT (Z350). Quarenta e cinco amostras cilíndricas (5 × 4 mm) foram confeccionadas a partir de cada um dos materiais por meio de uma matriz metálica. As matrizes foram preenchidas em incremento único para as resinas compostas Bulk Fill e em dois incrementos para as resinas compostas incrementais. As amostras foram armazenadas à seco no escuro à temperatura ambiente por 24 h antes da realização dos testes. O grau de conversão (GC) foi determinado utilizando a Espectroscopia de Infravermelho com Transformada de Fourier (FTIR). O teste de nanoindentação foi realizado nas superfícies de cada espécime, para obtenção da dureza (H) e módulo de elasticidade (E). Os dados foram submetidos a ANOVA 1 fator e teste de Tukey (α=0.05). Quanto o GC%, o maior foi obtido pelo grupo Z350 (69,92  3,5), e o grupo FBF (60,68  2,1) apresentou o valor significativamente inferior quando comparado com os outros grupos. Quanto os valores da nanodureza (GPa), os grupos FBF (0,3  0,02) e ED (0,3  0,01) apresentaram os menores valores de nanodureza e os grupos Z350 (0,9  0,04 ) e FBP (0,8  0,05 ) apresentaram os maiores valores de nanodureza. Quanto os valores do módulo de elasticidade (GPa), o grupo FBP apresentou os maiores valores de módulo de elasticidade (17,7  0,5) e o grupo FBF apresentou os menores valores de módulo de elasticidade (8,6  0,4). Conclui-se assim, que o compósito incremental (Filtek™ Z350XT) apresentou o maior desempenho do GC e o compósito Bulk Fill (Filtek™ Bulk Fill Flow) exibiu os menores valores de módulo de elasticidade e nanodureza. / The aim of this study was to evaluate the degree of conversion, hardness and elastic modulus of three Bulk Fill composites and two incremental-fill composites. The resin-composites: Filtek™ Bulk Fill (FBP), Tetric N-Ceram Bulk Fill (TBF), Filtek™ Bulk Fill Flow (FBF); and two incremental-fill composites: Empress Direct (ED), Filtek ™ Z350XT (Z350) were tested. Forty-five cylindrical specimens (5 × 4 mm) were made from each material in a metallic mold. Mold was filled in one increment for the Bulk Fill composites and in two increments for the incremental-fill composites. Specimens were stored dry in dark at room temperature for 24 h before testing. Degree of conversion (DC) was determined using Fourier transform infrared spectroscopy (FTIR). Nanoindentation was performed on the surfaces of each specimen, to obtain the hardness (H) and elastic modulus (E). Data for DC and H and E were analyzed by one-way ANOVA, Tukey's test (all at p<0,05). Z350 group (69.92  3.5) showed the highest DC% and FBF group (60,68  2,1) showed the lowest values when compared with the other groups. FBF (0.3  0.02) and ED (0,3  0,01) groups showed the lowest values for nanohardness (GPa) and Z350 (0,9  0,04 ) and FBP (0,8  0,05) groups showed the highest values for nanohardness. FBP group (17,7  0,5) showed the highest values for elastic modulus and FBF group (8.6  0.4) showed the lowest values for elastic modulus (GPa). It was concluded that incremental-fill composite (Filtek™ Z350XT) showed the highest performance DC and Bulk Fill composite (Filtek™ Bulk Fill Flow) showed the lowest values for elastic modulus and nanohardness.

Page generated in 0.0407 seconds