• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 334
  • 16
  • 9
  • 9
  • 9
  • 9
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 359
  • 248
  • 94
  • 80
  • 69
  • 56
  • 54
  • 54
  • 51
  • 51
  • 50
  • 44
  • 43
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Efeito de tecnicas de fotoativação na adaptação marginal e dureza Knoop de um composito restaurador fotoativado por tres fontes de luz / The effect of photoactivation technics in the marginal adaptation and Knoop hardness of a restorative when used three light curing units

Alves, Eliane Bemerguy 14 September 2005 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T09:04:33Z (GMT). No. of bitstreams: 1 Alves_ElianeBemerguy_D.pdf: 642464 bytes, checksum: a986353a680e6d427281d2a4f0c5d3e7 (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo foi avaliar a adaptação marginal e a dureza Knoop da resina Filtek Z250, cor A2 (3M-ESPE) utilizada para restaurar 90 cavidades, com margens em dentina, confeccionadas na face vestibular de incisivos bovinos, empregando três técnicas e três métodos de fotoativação. As cavidades foram padronizadas com dimensões de 3mm no sentido mesio-distal; 3mm no sentido inciso-cervical e 1,5mm de profundidade. Os grupos, com 10 restaurações cada, foram divididos de acordo com a técnica de fotoativação: direta; transdental ou mista, e método de fotoativação, que correspondem a variações na fonte de luz: halógena com 600mW/cm² (XL 2500/3M), arco de plasma de xenônio com 1340mW/cm² (Apollo 95E/DMD) e LED com 500mW/cm² (Ultrablue IS/DMC). Os tempos para cada etapa de fotoativação foram estabelecidos em 20s para os aparelhos fotoativadores Ultrablue IS e XL 2500 e 9s para o Apollo 95E. A análise da adaptação marginal foi realizada em fotos digitais, obtidas das superfícies das restaurações, após 24 horas de armazenagem, polimento padronizado e pigmentação com vermelho ácido a 1% em propileno glicol (Caries Detector- Kuraray). Foi utilizado o programa analisador de imagens, UTHSCSA - Image Tool, tendo como referência a medida de 1mm de um paquímetro digital (Mitutoyo, Japão) escaneado junto com cada restauração. As medidas de dureza Knoop foram obtidas no topo e na base da restauração, usando o microdurômetro HMV 2 (Shimadzu-Japão) com carga de 50 gramas atuando por 15 segundos. Em cada corpo-de-prova foram feitas seis endentações. Os dados foram submetidos à Análise de Variância e as médias comparadas pelo teste de Tukey (5%) e mostraram que independente do tipo de unidade fotoativadora, o emprego da técnica mista reduziu o percentual de fendas entre o material restaurador e o dente, determinando melhor adaptação marginal em relação à técnica direta, sendo que a técnica transdental não diferiu estatisticamente das demais. A adaptação marginal não foi influenciada pelas diferentes unidades de fotoativação utilizadas neste estudo, quando comparadas dentro da mesma técnica. A técnica de fotoativação direta apresentou as maiores médias de dureza em relação à mista e transdental, sendo que a transdental apresentou os menores valores de dureza. Independente da técnica de fotoativação empregada, o aparelho LED (Ultrablue IS) apresentou os maiores valores de dureza em relação ao Apollo 95E. Nenhuma diferença estatística foi observada nos valores de dureza Knoop entre os aparelhos LED e XL 2500 e XL 2500 e Apollo 95E / Abstract: The aim of this study was to evaluate marginal adaptation and Knoop hardness of the resin Filtek Z250 A2 (3M-ESPE). Ninety cavities, with margins in dentine, in the vestibular face of incisive bovine teeth were restored using three techniques and three photoactivation methods. The cavities were standardized with dimensions: 3mm mesio-distal; 3mm incisive-cervical, and 1.5mm deep. The groups, with 10 restorations each, were divided according to the photoactivation technique: direct; transdental or mixed, and method of photoactivation that correspond to variations in the light source: halogen light with 600mW/cm² (XL 2500/3M), xenon plasma arc with 1340 mW/cm² (Apollo 95E/DMD) and LED with 500mW/cm² (Ultrablue IS/DMC). The periods for each photoactivation stage were established in 20s for the units Ultrablue IS and XL 2500 and 9 s for the Apollo 95E. Marginal adaptation analysis was carried out in digital photografy, obtained from the surfaces of restorations, 24 hours after storage, with standard polish and with red acid pigmentation at 1% in propylene glycol (Cáries Detector - Kuraray). The program image analyzer, UTHSCSA - Image Tool was used , having as reference the measure of 1mm of a digital caliper (Mitutoyo, Japan) scanned with each restoration. The measures of Knoop hardness were obtained on the top and on the base of the restoration, using the microhardness unit HMV 2 (Shimadzu-Japan) with load of 50 grams for 15 seconds. In each specimen were made six indentations. The data were submitted to the Analysis of Variance and the averages compared by Tukey's test (5%) and showed that independent of the type of photoactivating unit the use of the mixed technique reduced the percentile of gaps between the restoring material and the tooth, determining better marginal adaptation in relation to the direct technique. The transdental technique did not differ statistically from the others. The marginal adaptation was not influenced by the different photoactivation units used in this study, when compared inside the same technique. The technique of direct photoactivation showed the highest averages of hardness in relation to the mixed and transdental ones, and the transdental presented the lowest hardness values. Independent of the photoactivation technique used, the Ultrablue IS nit presented the highest hardness values in relation to Apollo 95E. No statistical difference was observed on hardness values between the units Ultrablue IS and XL 2500 and XL 2500 and Apollo 95E / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
172

Avaliação da qualidade da união resina composta-dentina obtida pelo emprego de materiais/tecnicas que visam minimizar os efeitos da umidade dentinaria sobre a longevidade das restaurações adesivas / Evaluation of the quality of resin/dentin bonds obtained by using techniques/materiais that intent to minimize the effect of dentin wetness on the longevity of adhesive restorations

Silva, Safira Marques de Andrade e 12 December 2009 (has links)
Orientador: Marcela Rocha de Oliveira Carrilho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T16:52:08Z (GMT). No. of bitstreams: 1 Silva_SafiraMarquesdeAndradee_D.pdf: 1576367 bytes, checksum: 1f6e7c3cd256a0690cb307270c1569c0 (MD5) Previous issue date: 2008 / Resumo: O objetivo geral desta pesquisa foi avaliar materiais e procedimentos empreendidos para incrementar a durabilidade das restaurações adesivas. Os objetivos específicos foram: 1) avaliar o efeito da aplicação de uma camada adicional de adesivo e de um agente de união com característica hidrofóbica e livre de solventes na permeabilidade da dentina hibridizada com adesivos convencionais de 2 passos; 2) avaliar os efeitos decorrentes da aplicação do oxalato de potássio na durabilidade da interface de união obtida com adesivos convencionais e 3) determinar se a aplicação prévia do oxalato de potássio na dentina condicionada interfere na dureza Knoop dos adesivos. No primeiro estudo, a permeabilidade dentinária foi mensurada utilizando-se um medidor automático de fluxo, antes e após a aplicação dos sistemas adesivos nas condições experimentais citadas. Os resultados mostraram que nenhum dos adesivos foi capaz de prevenir a passagem de fluidos através da sua estrutura polimerizada. Porém, a aplicação de uma camada de um agente de união hidrofobico e livre de solventes reduziu significantemente a permeabilidade da dentina hibridizada com adesivos convencionais de 2 passos. Já no segundo estudo, testes de resistência adesiva (RA) foram realizados 24 horas após o procedimento adesivo ou após 12 meses de armazenagem em água. Os espécimes foram preparados para observação em microscopia eletrônica de varredura para avaliação do modo de fratura. Os resultados mostraram que a associação do oxalato de potássio aos sistemas adesivos reduziu significantemente a RA dos mesmos. Após o período de armazenagem, a RA foi significantemente reduzida em todos os grupos. No entanto, esta queda foi significantemente menor para os grupos tratados com oxalato. Finalmente, no terceiro estudo, testes de dureza foram realizados em microdurômetro e expressos como dureza Knoop (KHN). Os resultados mostraram que a associação do oxalato de potássio aos sistemas adesivos convencionais reduziu a KHN inicial dos mesmos. / Abstract: The general aim of this study was to evaluate materials and techniques that are thought to increase the longevity of adhesive restorations. The specific aims of this study were: 1) to test whether the application of an extra layer of the respective adhesive or the application of a hydrophobic, non-solvated bonding agent would interfere on the permeability of dentin hybridized with two-step etch-and-rinse adhesives; 2) to test whether the pretreatment of acid-etched dentin with potassium oxalate gel has an effect on the durability of resin-dentin interface created with etch-and-rinse adhesives; and 3) to determine whether the hardness of etch-and-rinse adhesives is affected by the pretreatment of acid-etched dentin with potassium oxalate gel. In the first study, dentin permeability was measured with an automatic record device, before and after dentin surfaces were bonded with the adhesives in the cited experimental conditions. The results showed that none of the adhesives or experimental treatments was capable to block completely the fluid transudation across the treated dentin; however, the application of the hydrophobic nonsolvated bonding agent resulted in significant reductions in the fluid flow rate. In the second study, the resin-dentin bond strength of the adhesives was tested immediately (i.e. 24 hours) and after 12 months of storage. The results showed that the pretreatment of dentin with potassium oxalate affect negatively the baseline resin-dentin bond strength of dentin specimens. After storage, the bond strength of resin-bonded interfaces was significantly reduced for all tested groups. Nevertheless, the decrease in bond strength values was significantly lower for oxalate-treated specimens than for controls. Finally, in the third study, the specimens' hardness was determined with a hardness tester and express as Knoop Hardness (KHN). The results showed that the baseline KHN of the adhesives applied to acid-etched dentin pretreated with potassium oxalate was significantly lower than that exhibited by their respective controls. / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
173

Avaliação da adaptação marginal e resistencia compressiva de restaurações esteticas tipo onlay e da dureza knoop de um cimento resinoso dual / Evaluation of marginal fit and compression strenght of onlay esthetic restorations and Knoop hardness of a dual-cured resin cements

Paula, Andreia Bolzan de 13 February 2007 (has links)
Orientador: Regina Maria Puppin-Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T05:25:28Z (GMT). No. of bitstreams: 1 Paula_AndreiaBolzande_M.pdf: 1101741 bytes, checksum: 8ff48065954bc02fa4336247fc151298 (MD5) Previous issue date: 2007 / Resumo: O avanço da Odontologia Estética tem sido impulsionado pela introdução de novos compósitos resinosos e técnicas restauradoras. Para amenizar as falhas associadas à contração de polimerização, a técnica indireta tem se tornado uma alternativa na restauração de dentes com preparos extensos. Entretanto, a polimerização incompleta do agente cimentante pode ocasionar redução do desempenho físico e mecânico da restauração. Dessa forma, os objetivos desta dissertação foram: (1) avaliar o efeito da técnica restauradora e do tratamento termo/mecânico na adaptação marginal e resistência compressiva de restaurações estéticas tipo onlay fixadas com cimento resinoso e (2) a influência de diferentes espessuras de compósito resinoso e distâncias da ponta ativa do aparelho fotoativador na dureza Knoop do agente cimentante Rely-X ARC utilizado nas restaurações indiretas. No estudo 1, preparos tipo onlay foram realizados em 50 terceiros molares hígidos e restaurados com compósito resinoso Z-250. Os dentes foram separados em grupos de acordo com a técnica restauradora (direta/indireta) e a ciclagem termo/mecânica. Para a análise da adaptação marginal foi aplicada uma solução corante nas margens da restauração e as áreas coradas foram consideradas como presença de fendas marginais, as quais foram mensuradas através do software Image Tool 3.0. Todos os espécimes foram submetidos ao teste de resistência à compressão. No estudo 2 foi utilizado um incisivo bovino incluído em resina de poliestireno. A face vestibular foi planificada e sobre ela aplicada uma película de PVC e uma matriz de borracha, dentro da qual foi inserido o cimento resinoso Rely-X ARC e uma nova película de PVC. Discos de compósito resinoso, de espessuras diferentes, foram confeccionados e inseridos individualmente sobre este conjunto e fotoativados por 40 segundos, variando a distância da ponta ativa do fotoativador. Após armazenagem por 24h a 37oC, as amostras foram seccionadas longitudinalmente ao meio e polidas para mensuração da dureza Knoop em 3 profundidades do cimento. No estudo 1, não houve diferença estatisticamente significativa entre as técnicas restauradoras quanto à presença de fendas, entretanto, o tratamento termo/mecânico influenciou significativamente o aumento de fendas marginais. Na resistência à compressão não houve diferença estatística significativa entre as técnicas restauradoras empregadas e o tratamento termo/mecânico também não influenciou significativamente à resistência à compressão (RC). No estudo 2, a distância da ponta ativa do fotoativador assim como diferentes espessuras do disco de resina composta, resultou em valores de dureza Knoop estatisticamente distintos, nas profundidades. O aumento da espessura do disco de compósito resinoso ocasionou diminuição dos valores de dureza do cimento. Foi observado diminuição dos valores de dureza apenas quando foi utilizada a distância da ponta do fotoativador de 1mm. As regiões de base e centro apresentaram, respectivamente, os menores e maiores valores de dureza Knoop. Com base nos resultados obtidos pode-se concluir que as técnicas direta e indireta para restauração tipo onlay apresentaram similar resistência à fratura por compressão. A adaptação marginal foi influenciada pelo tratamento termo/mecânico; com o aumento da espessura do compósito restaurador e da distância do fotoativador, houve redução dos valores de dureza do cimento resinoso / Abstract: Esthetic Dentistry has advanced increasingly with the introduction of new resin composites and restorative techniques. To reduce failures associated with polymerization contraction, indirect technique has become an alternative to restoration of teeth with extensive preparations. However, the incomplete polymerization of luting agent can cause a decrease in the physical/mechanical performance of restorations. The objectives of this dissertation were to evaluate: (1) the effect of restorative technique and thermo/mechanical cycling on themarginal adaptation and compressive strength of onlay esthetic restorations bonded with luting resin agent and (2) the influence of different thickness of resin composite discs and the distances of tip of curing unit on Knoop hardness of luting agent Rely-X ARC used in indirect restorations. In the study 1, onlay cavity preparations were performed in 50 sound third molars that were restored with resin composites Z-250. The teeth were divided in groups according to the restorative technique (direct/indirect) and the thermal/mechanical cycling. To analyze the marginal adaptation, a dye solution was applied on the restoration margins and the dyed areas were considered as marginal gaps and measured by means of Image Tool 3.0 software. All specimens were submitted to mechanical test of compressive strength. In the study 2, a bovine incisor was embedded in a polystyrene resin. The buccal surface was ground flatted and over it was applied a PVC pellicle and a rubber mold. The luting cement Rely-X ARC was inserted into the mold and a new PVC pellicle was applied. Resin composite discs, with different thickness, were performed and placed individually over this set (tooth/luting cement) and polymerized for 40 seconds, modifying the distance of tip of light curing. After storing at 37o C for 24 hours, specimens were longitudinally sectioned in two equal parts and polished to measure the Knoop hardness in three depth of cement. In the study 1, there was no statistically difference between the restorative techniques in relation to marginal gaps; however, thermal/mechanical cycling exerted significant influence on the increase of marginal gaps. About the compressive strength, any statistically difference was observed among the restorative techniques, independent of the thermal/mechanical cycling. In the study 2, the distance of tip of curing unit and distinct thickness of composite resin discs resulted in statistically different Knoop values when deepness was analyzed. The increase of resin disc thickness causes reduction on the hardness values of cement. Reductions on hardness values were observed only with 1mm tip curing unit distance. The base showed the lowest means while the center showed the highest. Based in the results obtained it could be concluded that direct and indirect techniques to onlay restoration had similar compressive strength. Marginal adaptation was influenced by thermal/mechanical cycling; increasing of resin composite thickness and distance of active tip of light curing unit, there was a reduction of hardness values of resin cement / Mestrado / Mestre em Materiais Dentários
174

Identificação molecular da dentina decidua em diferentes tratamentos quimicos : analise quimica, micro-mecanica e morfologica / Molecular analysis of primary dentin after different chemical treatments : Chemical, mechanical and morphological studies

Borges, Ana Flavia Sanches 05 July 2007 (has links)
Orientador: Regina Maria Puppin-Rontani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:32:12Z (GMT). No. of bitstreams: 1 Borges_AnaFlaviaSanches_D.pdf: 9249860 bytes, checksum: 185c997bcd0228668822df9171b2e4c2 (MD5) Previous issue date: 2007 / Resumo: Teoricamente, o suposto menor grau de mineralização da dentina decídua comparado à permanente, produziria comportamento diferente deste substrato após contato com soluções desproteinizantes/desmineralizantes, seguido de restaurações com materiais resinosos. O objetivo deste estudo foi fornecer novas informações científicas nos campos químicos, mecânico e morfológico em relação à qualidade do conteúdo mineral e orgânico da dentina decídua em comparação ao conteúdo da dentina permanente, após a ação de soluções desmineralizante/desproteinizante. No intuito de facilitar a apresentação desta tese, a mesma foi dividida em dois estudos, como descrito nas proposições seguintes. Estudo 1: Identificar a dentina decídua em comparação à permanente, na região de dentina média, após condicionamento com ácido fosfórico 35%. As análises foram: Espectroscopia Raman Transformada de Fourier (FT-Raman), Microscopia Eletrônica de Varredura/Espectroscopia de Energia Dispersiva (MEV/EED) e microdureza Knoop. Dez molares humanos, 5 decíduos e 5 permanentes, foram desgastados com fresa carbide até a dentina média e seccionados no sentido mesio-distal e vestíbulo-lingual, longitudinalmente. Metade da amostra foi destinada à espectroscopia FT-Raman e metade ao teste de dureza Knoop. Os grupos estudados foram (n=10): G1 (smear layer decídua); G2 (dentina decídua + ácido fosfórico 35%); G3 (smear layer permanente); G4 (dentina permanente + ácido fosfórico 35%). Espectros resultantes da análise química foram submetidos à análise de Cluster, com base nos componentes principais identificados. Análise MEV/EED foi realizada para complementar os dados obtidos pelo FT-Raman. O ensaio micromecânico de dureza foi realizado para cada grupo (n=5). Cinco impressões foram feitas em cada espécime com 100 µm de distância entre cada impressão. A média de cada grupo foi calculada e os valores foram submetidos à ANOVA e teste de Tukey (p<0,05). A análise FT-Raman revelou diferença entre os grupos. Conteúdo inorgânico: G3 foi o mais diferente, seguido pelo G4, enquanto G1 e G2 foram os mais similares entre si. MEV/EDS identificou os elementos químicos C, O, P, Ca e Zn. Conteúdo orgânico: G2 mostrou ser o mais diferente de todos os grupos, seguido pelo G4, enquanto G1 e G3 foram os mais similares entre si. O teste de dureza revelou não haver diferença significativa entre G1 vs G3 e G2 vs G4 (p>0,05), porém houve diferença significativa entre G1 vs G2 e G3 vs G4 (p<0,05). Estudo 2: Avaliar por meio da FT-Raman e MEV, a dentina coronária das paredes laterais da câmara pulpar, decídua e permanente, após ação da solução NaOCl 1% seguido de condicionamento com ácido fosfórico a 35%, simulando as alterações que podem ocorrer em dentes tratados endodonticamente, os quais apresentam cavidade tipo classe I restaurada com compósito cujo sistema de união requer condicionamento ácido total. Vinte molares humanos, 10 decíduos e 10 permanentes, foram seccionados no sentido mesio-distal, longitudinalmente. As secções dentinárias foram distribuídas entre os grupos (n = 5): Dentes decíduos (Grupos 1, 2, 3 e 4); dentes permanentes (grupos 5, 6, 7 e 8) : G1 e G5 ¿ dentina; G2 e G6 ¿ dentina irrigada com NaOCl 1% (30 min); G3 e G7 - dentina irrigada com NaOCl 1% (30 min) e condicionada com ácido fosfórico 35%; G4 e G8 - dentina condicionada com ácido fosfórico 35%. Após a análise FT-Raman, todos os espécimes foram preparados e avaliados em MEV. As alterações morfológicas foram classificadas de acordo com score pré-estabelecido. Resultados: Conteúdo inorgânico: Houve nítida diferença entre a dentina que compõe a câmara pulpar decídua e permanente. G1 e G4 mostraram ser muito similares entre si, seguido do G2 que foi intermediário entre eles e G3. G6 e G7 também foram altamente similares entre si, seguido do G8 que foi intermediário entre eles e G5. Conteúdo orgânico: G7 e G8 foram muito similares entre si; G2 foi intermediário; G4 e G6 foram altamente similares entre si, bem como G3 e G5, os quais foram similares ao G1. As fotomicrografias demonstraram haver diferença morfológica entre os grupos não tratados, tratados com NaOCl e tratados com NaOCl seguido de condicionamento ácido, sendo que os grupos apenas condicionados não diferiram daqueles tratados e condicionados. Conclusão Geral: O arranjo molecular do conteúdo inorgânico dos dentes decíduos é qualitativamente diferente do arranjo molecular do conteúdo inorgânico dos dentes permanentes, tanto na dentina da região média coronária quanto da câmara pulpar, sendo o NaOCl um agente capaz de alterar o conteúdo inorgânico quimicamente, tanto na dentina decídua quanto na permanente, porém não morfologicamente caso seja tratado com NaOCl e seguido pelo condicionamento com ácido fosfórico / Abstract: Theoretically, it is supposed to have lower degree of mineralization for primary dentin compared with permanent one could lead different behavior of this substrate after contact with deproteinizating/demineralizating solutions, followed by composite restorations. The aim of this study was provide scientific informations at chemical, mechanical and morphological levels regarding the quality of inorganic and organic content of primary dentin compared to permanent one, as well as after deproteinizating/demineralizating solutions action. In order to facilitate the accomplishment of this thesis, it was divided into two phases, as described on the following descriptions: Study 1: To recognize the primary dentin compared to permanent dentin in the middle of crown, with or without 35% phosphoric acid total etching. The analyses were: Fourier Transformed Raman Spectroscopy (FT-Raman); Scanning Electron Microscopy/Energy-Dispersive Spectroscopy (EDS/SEM) and Hardness Micromechanical Test, related to molecular and micro-mechanical areas. Ten human molars, 5 primary and 5 permanent, were abrading with carbide bur until reach the middle dentin simultaneously to smear layer production. Four parts per tooth were obtained, half designed to FT-Raman spectroscopy and half to hardness test. The studied groups were (n=10): G1 (primary dentin smear layer); G2 (35% phosphoric acid etched primary dentin); G3 (permanent dentin smear layer); G4 (35% phosphoric acid etched permanent dentin). Result spectros from chemical analysis were subject to Cluster analysis based on identified principal components. The EDS/SEM analysis was done in order to add the FT-Raman data. To hardness test, 5 specimens were included, polished, cleaned, and etching (G2, G4) before the test. Five indentations were recorded to each specimen under middle dentin surface with 100 µm of distance each others beginning with 50 µm apart from JAD. A mean was calculated by each group and these values were recorded. The results were subjected to ANOVA and Tukey test. FT-Raman analysis showed difference among groups. Inorganic content: G3 was the most different, followed by G4, while G1 and G2 were the most similar to each other. EDS/SEM identified the C, O, P, Ca and Zn chemical elements in dentin. Organic content: G2 was the most different of all groups, followed by G4, while G1 and G3 were the most similar. There were no difference of hardness between G1 vs G3 and G2 vs G4 (p>0.05), however, there were difference between G1 vs G2 and G3 vs G4 (p<0.05). Study 2: FT-Raman and SEM were used to evaluate chemically and morphologically the coronary dentin of pulp chamber laterals walls after 1% NaOCl action followed by 35% phosphoric acid total etching. The aim of this study was to simulate the changes that can occur in endodontically treated teeth with type class I cavity restored with composite and total etching adhesive systems. Twenty human molars, 10 primary and 10 permanent, were sectioned mesio-distally paralleled to long axis of teeth. Two parts of dentin pulp chamber, buccal and lingual lateral walls, were obtained from each tooth, providing 20 parts to primary as well as to permanent teeth, followed by division into groups (n = 5): Primary teeth (Groups 1, 2, 3 and 4); permanent teeth (groups 5, 6, 7 and 8) : G1 and G5 ¿ pulp chamber dentin ; G2 and G6 ¿ pulp chamber dentin irrigated with 1% NaOCl (30 min); G3 e G7 - pulp chamber dentin irrigated with 1% NaOCl (30 min) and etched by 35% phosphoric acid; G4 e G8 - pulp chamber dentin etched by 35% phosphoric acid. After FT-Raman analysis, all specimens were prepared and evaluated by SEM. The morphological changes were classified according a score. Results: Inorganic content: There was a clear difference between primary and permanent dentin pulp chamber. Within this division, G1 and G4 showed very similar profile between them, followed by G2 that was intermediated between them and G3. G6 and G7 showed are very similar between them, followed by G8 that was intermediated between them and G5. Organic content: G7 and G8 were very similar between them; G2 showed be intermediate; G4 and G6 were very similar between them as well as G3 and G5 that, in turn, were quite similar to G1. The photomicrographs showed difference among non-treated groups, NaOCl treated groups and NaOCl treated followed by phosphoric acid etched groups. The groups only acid etched not differ from NaOCl treated followed by acid etched groups. Therefore, the inorganic content of primary teeth is qualitatively different from inorganic content of permanent ones, both in middle dentin of crown as well as in pulp chamber dentin, but not morphologically in case of NaOCl treatment followed by phosphoric acid treatment / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
175

Analise da união e dos tecidos dentais (esmalte/dentina) adjacentes as restaurações com sistemas adesivos contendo fluoreto apos desafios cariogenicos in situ e in vitro / Analysis of adhesion and mineralized dental tissues (enamel/dentin) around restorations with fluoride-containing adhesive systems after cariogenic challenge in situ and in vitro

Pinto, Cristiane Franco 15 August 2018 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T12:58:19Z (GMT). No. of bitstreams: 1 Pinto_CristianeFranco_D.pdf: 8181087 bytes, checksum: 41321386cc6d99055932efad6dad9919 (MD5) Previous issue date: 2010 / Resumo: O objetivo deste estudo foi avaliar sistemas adesivos, tecidos dentais adjacentes (esmalte ou dentina) às restaurações e a união formada entre os adesivos e as estruturas dentais frente aos desafios cariogênicos in situ e in vitro. Para o estudo foram utilizados dentes bovinos e blocos dos tecidos dentais (esmalte e dentina) que foram restaurados com dois sistemas adesivos e resina composta. No estudo in situ; 11 voluntários utilizaram dispositivos palatinos contendo 2 amostras do grupo controle (substrato hígido sem preparo cavitário) de esmalte e dentina, e 6 amostras restauradas com os sistemas adesivos Clearfil Protect Bond (PB) ou One-Up Bond F Plus (OP) (em fases distintas) e com o compósito Filtek Z350. O desafio cariogênico consistiu de 2 fases (cada fase com um adesivo), sendo cada fase de 14 dias com intervalo de 10 dias entre elas. Os voluntários utilizaram solução de sacarose a 20%, 8X/dia e dentifrício fluoretado 3X/dia. Após cada etapa, o biofilme dental formado foi coletado e analisado. As amostras foram analisadas através de Microscopia de Luz Polarizada (MLP) e Microdureza Knoop para observação da extensão da lesão de cárie. Para o estudo in vitro foi realizado o preparo dos substratos e foram restaurados em esmalte e em dentina seguindo os grupos experimentais: 1-adesivo PB sem desafio cariogênico (DC); 2- adesivo PB com DC; 3- adesivo OP sem DC; 4- adesivo OP com DC. A partir dos blocos dentais restaurados foram obtidos espécimes para o ensaio de resistência da união com formato de paralelepípedos (palitos) e fatias para análise da interface da união em Microscopia Eletrônica de Transmissão (MET). Os espécimes (palitos ou fatias) foram submetidos à ciclagem de pH durante 8 dias. O resultado do ensaio de microdureza em esmalte e dentina mostrou maiores valores para PB nas profundidades mais superficiais e as imagens de MLP mostraram uma menor extensão da área de desmineralização para o adesivo PB que para o adesivo OP. Na análise bacteriológica, o adesivo PB levou a menor quantidade de colônias de Streptococcus totais e do grupo mutans em esmalte. A resistência de união não foi afetada pela ciclagem de pH e foi semelhante em esmalte para ambos adesivos, entretanto, em dentina, o adesivo PB apresentou maior resistência de união que o adesivo OP. Os adesivos produziram hibridização nos tecidos dentais, sem formações de fendas na interface de união. Concluiu-se que o adesivo PB produziu menor extensão de desmineralização dos substratos dentais após o desafio cariogênico e maior microdureza Knoop nas profundidades mais superficiais. Em algumas condições deste estudo, o adesivo PB reduziu a formações de colônias bacterianas. Embora a união formada pelos adesivos em esmalte foi semelhante, o adesivo PB mostrou maior resistência de união em dentina. / Abstract: The aim of this study was to evaluate adhesive systems, mineralized dental tissues (enamel and dentin) around restorations and the bonding formed by adhesives and dental structures in conditions of cariogenic challenge in situ and in vitro. This study used dental blocks (enamel/ dentin) from bovine teeth, which were restored with adhesive systems and a resin composite. For the in situ study: volunteers (n=11) wore intra-oral appliance containing 2 dental fragments without restoration (enamel or dentin) and six dental blocks with restorations made with self-etching primers Clearfil Protect Bond (PB) or One-up Bond F Plus (OP) (in two phases) and the Filtek Z350 composite: The cariogênico challenge was performed in two phases of 14 days (each phase with one adhesive). The volunteers dropped 20% sucrose solution 8x/day and used fluoridated dentifrice 3x/day. After each phase, the biofilm was collected and analyzed. The samples were analyzed by cross-sectional microhardness and polarized light microscopy (PLM) to determine the demineralization depth. For the in vitro study, bovine were prepared and bonded in enamel and dentine with Clearfil Protect Bond (PB) or One-Up Bond F Plus (OP) and restored with Filtek Z-350 composite resin, according to the groups: 1- PB without CC; 2- PB with CC; 3- OP without CC; 4- OP with CC. Restored teeth were sectioned in order to obtain sticks for microtensile bond strength or slabs for transmission electron microscopy. The specimens were submitted to pHcycling, which consisted of DE (8h/day) and RE (16h/day) cycles at 37ºC during days. Microhardness analysis showed that the enamel and dentin around restorations PB had higher values in superficial depths, and the PLM showed that PB resulted in lower demineralization depth than OP. The biofilm investigation indicated that PB produced lower number of bacterial colony of Streptococcus totais and mutans in enamel. The results showed that the pH-cycling regimen did not affect the bond strength to enamel or dentin for both adhesives; however, the bond strength to dentin was higher for PB. The adhesives produced hybridization and no gaps formation in both dental tissues. In conclusion, PB adhesive may result in lower enamel demineralization around restoration and higher microhardness in superficial depths. In some conditions, PB adhesive reduced the number of bacterial colony. Although the adhesives in enamel formed similar bonded interfaces, PB produced higher bond strength to dentin than OP. / Doutorado / Dentística / Doutor em Clínica Odontológica
176

Efeito de doses cronicas oscilantes de fluoreto no desenvolvimento de fluorose dental em ratos / Effect of chronic oscillating fluoride doses on dental fluorosis development in rats

Catani, Danilo Bonadia 02 November 2010 (has links)
Orientadores: Livia Maria Andalo Tenuta, Jaime Aparecido Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T10:27:51Z (GMT). No. of bitstreams: 1 Catani_DaniloBonadia_D.pdf: 3182260 bytes, checksum: 1cbcbeff9370ac4ee3fd869799aca3fe (MD5) Previous issue date: 2010 / Resumo: O efeito do fluoreto (F) no desenvolvimento de fluorose dental em animais expostos a doses crônicas constantes é bem conhecido, mas não há informações sobre o efeito de doses crônicas oscilantes, o que foi estudado neste trabalho. Além disso, não há estudos comparando diferentes métodos de quantificação de defeito de esmalte induzido pelo F, o que também foi avaliado. O estudo foi composto por três trabalhos. Foram utilizadas ratas fêmeas da linhagem Wistar com idade de 35 dias, as quais receberam água e ração ad libitum durante um período suficiente para permitir o completo crescimento dos incisivos (70 a 78 dias). Após, os animais foram anestesiados, o sangue foi coletado e os incisivos, mandíbulas e fêmures, removidos após a morte por hemorragia. A concentração de F no plasma, nos incisivos e nos ossos foi determinada usando um eletrodo íon específico. No primeiro estudo, 20 ratas foram divididas casualmente em 5 grupos: quatro grupos receberam água com concentrações constantes de F (0; 12,5; 25 ou 37,5 µg F/mL) e o outro grupo recebeu água contendo 12,5 e 37,5 µg F/mL, alternados a cada 72 h (média de exposição igual a 25 µg F/mL). Não foi observada diferença nas variáveis metabólicas e na gravidade de fluorose dental entre o grupo que recebeu doses oscilantes e o grupo que recebeu dose correspondente à média das oscilações (p > 0,05). No segundo estudo, foram utilizadas 58 ratas, as quais foram divididas casualmente em grupos expostos a diferentes concentrações de F na água (0 a 75 µg F/mL) constantes ou alternantes (12,5 e 75 µg F/mL) por períodos assimétricos (2 ou 8 dias). A exposição a doses oscilantes de F resultou em concentrações de F no sangue e ossos e fluorose dental semelhantes às observadas nos animais expostos à média das oscilações em função do tempo utilizado. No terceiro estudo, foram utilizadas 35 ratas, divididas casualmente em 7 grupos de 5 animais cada, que receberam água em concentrações crescentes de F: 0; 12,5; 25; 50; 62,5; 75 ou 100 µg F/mL. Os incisivos foram utilizados para avaliar 5 métodos de quantificação de fluorose: radiomicrografia, microdureza, microscopia de luz polarizada, análise de fluorescência e análise da imagem da superfície do esmalte segundo o padrão de bandas claras e escuras presentes na superfície do esmalte fluorótico de ratos. Radiomicrografia, microdureza e microscopia de luz polarizada só foram capazes de detectar fluorose sob altas concentrações de F (= 50 µg/mL) e a análise de fluorescência não permitiu diferenciação entre os grupos. A análise da imagem da superfície do esmalte foi satisfatória para quantificar fluorose, mesmo nas menores concentrações de F utilizadas nesse estudo, e foi utilizada para quantificar fluorose nos estudo subsequentes. Os resultados dos estudos sugerem que o efeito biológico da exposição crônica a doses oscilantes de F reflete a média do efeito das doses oscilantes de acordo com o tempo de exposição. A análise da imagem da superfície do esmalte se mostrou um método adequado para quantificar fluorose em incisivos de ratos. / Abstract: The effect of fluoride (F) on the development of dental fluorosis in animals chronically exposed to constant F doses is well known, but there is no information about the effect of chronic oscillating doses, and this was evaluated in the present study. Moreover, there are no studies comparing different methods of quantification of enamel defects induced by F, which was also evaluated. The study comprised of three experiments. Wistar female rats, aged 35 days, received water and food ad libitum during enough time to allow the full growth of the incisors (70 to 78 days). After, the animals were anesthetized, blood was collected and femurs, mandible bones and incisors were removed after their death by bleeding. F concentration in the blood plasma, bones and teeth was determined using ion-specific electrode. In the first study, 20 rats were randomly divided into 5 groups: four groups received water with constant F concentration at 0, 12.5, 25 or 37.5 µg F/mL and the other group received water containing 12.5 and 37.5 µg F/mL, which were alternated at each 72 h (mean exposure equals to 25 µg F/mL). No difference in metabolic variables and in severity of dental fluorosis between the group which received oscillating doses and the group receiving 25 µg F/mL was observed (p > 0.05). In the second study, 58 rats were randomly divided into groups which were chronically exposed to different F concentration in the water (0 to 75 µg F/mL), constant or oscillating (12.5 and 75 µg F/mL) for different periods of length (2 or 8 days). Exposure to oscillating F doses resulted in F concentrations in blood plasma and bones and enamel fluorosis similar to those observed in groups receiving F concentrations equal to the means of the oscillating range, according to the period length. In the third study, 35 rats were randomly divided into 7 groups of 5 animals, which received water at increasing F concentrations: 0, 12.5, 25, 50, 62.5, 75 or 100 µg F/mL. Incisors were used to assess fluorosis using five quantification methods: transverse microradiography, cross-sectional microhardness, polarized bright microscopy, quantitative light-induced fluorescence and image analysis of the enamel surface based on the pattern of white and dark bands present on rat fluorotic enamel. Transverse microradiography, cross sectional microhardness and bright field microscopy were only able to detect the fluorotic defect in the rat incisor when high F concentrations (= 50 µg F/mL) were used and quantitative ightinduced fluorescence analysis did not allow the differentiation among the groups. The image analysis method of the enamel surface was satisfactory to quantify dental fluorosis, even at low F concentrations, and was used to evaluate fluorosis in the subsequent studies. The present study suggests that the biological effect of F when an animal is exposed chronically to oscillating F doses may reflect the effect of the mean of the oscillating doses, according to exposure length. The image analysis of the enamel surface was a suitable method to quantify enamel fluorosis in rat incisors. / Doutorado / Saude Coletiva / Doutor em Odontologia
177

Influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada híbrida e camada de adesivo / The influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the hybrid layer and adhesive layer

Tamile Rocha da Silva Lobo 03 September 2013 (has links)
Este estudo avaliou a influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada de adesivo e camada hibrida de uma resina composta à dentina humana, por meio de ensaio de microtração e nanoedentação. Os fatores de variação estudados foram dois sistemas adesivos com estratégias de aplicação distintas Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) e Clearfil SE Bond (Kuraray Co., Osaka, Japan), e ainda foram realizados tratamentos no substrato dentinário utilizando duas concentrações de digluconato de clorexidina sendo estas 2% e 0,2% e grupos controle sem tratamento com clorexidina. As unidades experimentais foram compostas por 48 molares humanos hígidos divididos aleatoriamente em 6 grupos (n=8). Nestes foram aplicados os procedimentos adesivos e realizados os tratamentos de superfície, com clorexidina, previamente aos procedimentos adesivos. Após esta etapa foram confeccionadas as restaurações com espessura de 5mm sobre as superfícies dentinárias. Após 24h de armazenamento em água destilada, os dentes restaurados foram cortados para a obtenção de corpos de prova em forma de palito, com secção transversal de aproximadamente 1mm2. De cada grupo foram selecionados aleatoriamente 5 palitos para o ensaio de dureza. O restante dos palitos viáveis de cada dente foram submetidos ao teste de microtração a uma velocidade de 0,5mm/min até que ocorresse a fratura da interface adesiva. Para o teste de nanoedentação cada um dos 5 palitos referentes aos 6 grupos estudados receberam 10 endentações, sendo 5 na camada de adesivo e 5 na camada hibrida, com distância de 10m entre si. Essas endentações foram realizadas com ultramicrôdurometro (DUH-W211S, Shimadzu Co., Tokyo, Japan). Os dados referentes aos testes de microtração dos seis grupos foram submetidos à análise de variância e teste de Tukey (p<0,05). As médias dos grupos foram: Grupo 1: Clearfil SE controle ( 28.50±0.47); Grupo 2: Adper Scotchbond controle (43.90±7.26); Grupo3: Clearfil SE/ clorexidina 2% (30.43±6.59); Grupo 4: Adper Scotchbond/ clorexidina 2% (39.21±4.69); Grupo 5: Clearfil SE 0,2%( 27.28±7.05); Grupo 6: Adper Scotchbond/ clorexidina 0,2% (35.70±6.43). Na comparação entre as médias dos grupos obteve-se que nenhum dos adesivos testados apresentou alteração na sua resistência de união com o uso do digluconato de clorexidina a 2% ou a 0,2% em análise imediata. Os grupos em que foi utilizado o adesivo Scotchbond apresentaram maiores valores de resistência de união que os grupos em que foi utilizado o sistema adesivo autocondicionante (Clearfil) independente da realização ou não do tratamento de superfície com digluconato clorexidina. Os valores de dureza da camada de adesivo não apresentaram diferenças estatisticamente significantes entre os grupos controle ou entre tratamentos, apenas o grupo com tratamento prévio Clearfil SE/Clorexidina 0,2% apresentou maior valores de dureza na camada de adesivo quando comparado ao grupo Scotchbond com a mesma concentração de clorexidina. Quanto aos valores de dureza da camada híbrida o grupo controle Clearfil SE quando comparado ao grupo Clearfil SE/Clorexidina 2% apresentou menor valor de dureza da camada hibrida. O Scotchbond controle apresentou menor valor de dureza na camada hibrida quando comparado ao grupo Scotchbond com clorexidina a 0,2%. O uso do digluconato de clorexidina nas concentrações 2% e 0,2% em dentina humana, apesar de ter apresentado discretas alterações na dureza da camada hibrida e camada de adesivo, não tiveram a capacidade de afetaram os valores de adesão à dentina dos diferentes adesivos testados. / This study evaluated the influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the adhesive layer and hybrid layer of a composite resin to dentin, using microtensile test and nanoindentation. The variation factors studied were two adhesive systems with different implementation strategies Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) and Clearfil SE Bond (Kuraray Co., Osaka, Japan), and were still held treatments to dentin using two concentrations of chlorhexidine digluconate and these 2% and 0.2% untreated control groups with chlorhexidine. The experimental units were composed of 48 human molars were randomly divided into 6 groups (n = 8). These procedures were applied adhesives and surface treatments performed with chlorhexidine prior to bonding procedures. After this step the restorations were made with 5mm thickness on the dentin surfaces. After 24 hours storage in distilled water, the samples were cut to obtain specimens toothpick shaped cross-section of approximately 1mm2. Each group were randomly selected 5 toothpicks for hardness testing. The remaining viable sticks of each tooth were subjected to microtensile testing at a crosshead speed of 0.5 mm / min until the fracture of the adhesive interface. To test nanohardness each of the five toothpicks referring to six groups received 5 indentations in the adhesive layer and 5 indentations in the hybrid layer with 10m away from each other. These indentations were performed with the equipament DUH-W211S (Shimadzu Co., Tokyo, Japan). The data relating to microtensile test of the six groups were subjected to analysis of variance and Tukey test (p <0,05). The means of the groups were: Group 1: Clearfil SE control (28.50 ± 0:47), Group 2: Adper Scotchbond control (43.90 ± 7.26); Group3: Clearfil SE / 2% chlorhexidine (30.43 ± 6:59), Group 4: Adper Scotchbond / 2% chlorhexidine (39.21 ± 4.69), Group 5: Clearfil SE 0.2% (27.28 ± 07.05), Group 6: Adper Scotchbond / chlorhexidine 0.2% (35.70 ± 6:43). Comparing the means of the groups it was found that none of the adhesives tested showed a change in its bond strength with the use of chlorhexidine gluconate 2% or 0.2% in immediate analysis. The groups that used Scotchbond showed higher bond strength than the groups that used the adhesive system (Clearfil) regardless of performance or not the surface treatment with chlorhexidine digluconate. The hardness values of the adhesive layer did not show statistically significant differences between the control groups or between treatments, the group previously treated with Clearfil SE / Chlorhexidine 0.2% showed higher hardness values in the adhesive layer when compared to Scotchbond with the same concentration of chlorhexidine. As for the hardness of the hybrid layer control group Clearfil SE when compared to Clearfil SE / 2% Chlorhexidine showed lower hardness value of the hybrid layer. The Scotchbond control showed lower hardness value in the hybrid layer when compared to Scotchbond with 0.2% chlorhexidine.The use of chlorhexidine gluconate at concentrations 2% and 0.2% in human dentin, despite having discrete changes in the hardness of the hybrid layer and adhesive layer, did not have the ability to affect the values of adhesion to dentin of different adhesives tested.
178

Influência das unidades fotoativadoras e do material restaurador indireto sobre a dureza de um cimento resinoso dual auto-adesivo e um cimento resinoso dual convencional por meio de teste de nanoendentação / Influence of curing units and restorative indirect material on hardness of a dual cure self-adhesive resin cement and dual cure conventional resin cement through nanoindentadion test

Rosiane Nogueira Kuguimiya 05 December 2013 (has links)
O objetivo deste estudo foi avaliar a dureza de um cimento resinoso dual autoadesivo (RelyX U200) e um cimento resinoso dual convencional (RelyX ARC) fotoativados sob materiais restauradores indiretos, utilizando unidades fotoativadoras com diferentes comprimentos de ondas (LED Elipar Freelight 2, LED Bluephase, Laser AccuCure 3000TM), por meio de teste de nanoendentação. Para a obtenção dos espécimes foram utilizados incisivos bovinos que após profilaxia, foram submetidos a cortes no limite amelo-cementário para a separação da porção coronária. Após inclusão, os espécimes foram submetidos ao desgaste para exposição de dentina e padronização do substrato. Para simular clinicamente restaurações indiretas foram confeccionadas peças em cerâmica IPS e.max® Press (Ivoclar Vivadent) e em resina composta indireta SR Adoro (Ivoclar Vivadent) que foram cimentadas nas superfícies dentinárias. Os espécimes foram seccionados longitudinalmente em baixa velocidade e constante irrigação e polidos em politriz. Foi estabelecido um grupo controle positivo, no qual o cimento foi fotoativado sem a interposição de material restaurador indireto e um grupo controle negativo, no qual, após a cimentação do material restaurador indireto, a fotoativação foi suprimida, ocorrendo apenas a polimerização química do cimento. Todos os espécimes foram armazenados em água destilada a 37°C durante 7 dias e após esse período, foram submetidos ao teste de nanoendentação na linha de cimentação, com o auxílo do ultra-microdurômetro (Shimadzu Dynamic Ultra Micro Hardness Tester). O ciclo aplicado foi de 100mN. Foram realizadas cinco nanoendentações em cada espécime, cujas médias resultaram nos valores de cada superfície. Os resultados obtidos foram submetidos à Análise de Variância e Teste de Tukey (p<0,05). Podese concluir que o cimento RelyX ARC apresentou maiores valores de dureza do que o RelyX U200 e este foi mais dependente da fotoativação para alcançar uma polimerização adequada. A dureza dos cimentos resinosos avaliados foi influenciada negativamente pela interposição do material restaurador indireto e apenas os LEDs foram capazes de manter o mesmo grau de polimerização dos cimentos quando interposto um material restaurador indireto. / This study aimed to evaluate the hardness of a dual cure self-adhesive resin cement (RelyX U200) and a dual cure conventional resin cement (RelyX ARC) light curing units with different wavelengths (Elipar Freelight 2 LED, Bluephase LED, AccuCure 3000TM Laser) through nanoindentadion test. To obtain the specimens bovine incisors were used after prophylaxis. The tooth were sectioned at the limit amelocement for the separation of the coronal portion. After inclusion, the dentin surface of the specimens were exposed to standardize the substrate. To clinically simulate indirect restorations ceramic pieces were made (IPS e.max® Press/Ivoclar Vivadent) and indirect composite resin (SR Adoro/Ivoclar Vivadent) were cemented on dentin surfaces. The specimens were sectioned longitudinally at low speed with constant irrigation and polished. A positive control group was stablished, in which the cement was light cured without the interposition of indirect restorative material, and a negative control group, in which, after cementation of the indirect restorative material, the light curing was removed, occurring only the chemical polymerization of the cement. All specimens were stored in distilled water at 37°C for 7 days. Nanoindentadion hardness of the cement layer was measured under 100mN load (Shimadzu Dynamic Ultra Micro Hardness Tester). Five nanoindentations in each specimen were obtained, which resulted in the average values of each surface. Data were statistically analyzed using ANOVA and Tukey test (p<0,05). RelyX ARC pesented higher values of hardness than RelyX U200 and this was more dependent on the polymerization. The hardness of the evaluated resin cements was negatively influenced by the interposition of an indirect restorative material and only the LEDs were able to maintain the same degree of polymerization of the cement when an indirect restorative material was used.
179

Influência de características de equipamentos fotoativadores e tempos de fotoativação na polimerização de resinas compostas bulk fill / Influence of characteristics of light curing units and photoactivation times on the polymerization of bulk fill composite resins

Carlos Alberto Kenji Shimokawa 12 June 2017 (has links)
Os equipamentos fotoativadores apresentam diferentes características e elas podem influenciar na polimerização de restaurações em resina composta. O objetivo desse estudo foi avaliar as características de quatro equipamentos fotoativadores e verificar sua influência na polimerização de duas resinas compostas bulk fill. Os equipamentos fotoativadores Bluephase 20i (Ivoclar Vivadent), Celalux 3 (Voco), Elipar DeepCure-S (3M ESPE) e Valo Grand (Ultradent) foram avaliados quanto ao diâmetro da ponteira, à potência, à irradiância, ao espectro de emissão e ao perfil do feixe de luz, e utilizados na fotoativação das resinas compostas Filtek Bulk Fill Posterior Restorative - A2 (3M ESPE) e Tetric EvoCeram Bulk Fill - IVA (Ivoclar Vivadent). Matrizes de Delrin® brancas foram utilizadas para confecção de espécimes de 12 mm de diâmetro e 4 mm de espessura, sendo a dureza nas superfícies de topo e fundo desses espécimes avaliadas com 97 endentações por superfície, no centro e em todas as direções. Uma matriz de dente foi confeccionada para a avaliação da dureza transversal de restaurações de 12 mm de largura e 4 mm de profundidade, sendo feitas endentações no centro e nas regiões mesial e distal (4,5 mm do centro), a cada 0,5 mm de profundidade. Após os ensaios de microdureza, os espécimes foram imersos em Tetrahidrofurano por 24 horas. A transmissão de luz através dos espécimes também foi avaliada. Os dados obtidos foram analisados estatisticamente com testes de ANOVA e Tukey, com nível de significância de 5%, e teste t. Os valores de dureza mensurados nos espécimes confeccionados com auxilio das matrizes de Delrin® mostram que os fatores resina composta e superfície mensurada exercem influência sobre os resultados (p<0,05). A interação entre o fator equipamento fotoativador e a região das endentações também influenciou os resultados, sendo que o uso do Valo Grand não resultou em diferenças estatisticamente significantes entre os valores mensurados no centro e na região externa (p>=0,05). Quando o Celalux 3 foi utilizado, houve diferença estatisticamente significante entre os valores obtidos nas regiões central e externa (p<0,05). Os resultados de dureza mensurados nos espécimes confeccionados com a matriz feita com uso de dente humano mostraram diferenças estatisticamente significantes entre 10 e 20 segundos de fotoativação (p<0,05). O fator resina composta também exerceu influência sobre os resultados. Houve diferença estatisticamente significante entre o centro e as regiões mesial e distal quando todos os equipamentos fotoativadores foram utilizados (p<0,05). Também foi observada diferença estatisticamente significante entre os valores obtidos nas caixas mesial e distal dos espécimes (p<0,05). Os resultados de transmissão de luz mostraram que pouca luz violeta chega ao fundo dos espécimes e a posição e o tamanho da ponteira dos equipamentos fotoativadores influenciam na irradiância da luz que chega no fundo das caixas proximais de restaurações MOD. Os equipamentos fotoativadores apresentaram diferenças, sendo que elas, associadas à diferentes protocolos de fotoativação, influenciaram na dureza de restaurações confeccionadas com resinas compostas bulk fill. / Light curing units can present different characteristics and they can influence the polymerization of composite resin restorations. The aim of this study was to analyze the characteristics of four light curing units and verify their influence on the polymerization of two bulk fill composite resins. The light curing units Bluephase 20i (Ivoclar Vivadent), Celalux 3 (Voco), Elipar DeepCure-S (3M ESPE) and Valo Grand (Ultradent) were analyzed regarding their tip diameter, radiant power, irradiance, emission spectrum and light beam profile, and used for the photoactivation of the composite resins Filtek Bulk Fill Posterior Restorative - A2 (3M ESPE) and Tetric EvoCeram Bulk Fill - IVA (Ivoclar Vivadent). White Delrin® matrices were used for the confection of 12 mm diameter and 4 mm depth specimens, being their hardness measured at the top and bottom surfaces, with 97 indents per surface, at the center and all the directions. One matrix, made using human tooth, was used for the confection of 12mm wide and 4 mm depth restorations, in which the transversal hardness was measured. Indents were made at the center and the mesial and distal regions (4,5 mm from the center) of the restorations, at every 0,5 mm in depth. After the microhardness tests, the specimens were immersed in Tetrahydrofuran for 24 hours. The light transmission through the specimens was also analyzed. The obtained data was statistically analyzed with the ANOVA and Tukey tests, with a 5% significance level, and t test. The hardness values measured at the specimen made with the Delrin® matrices showed that the factors composite resin and surface influenced the results (p<0,05). The interaction between the light curing unit and the region of the indents also influenced the results, when the Valo Grand was used, there was no statistically significant difference between center and the external regions (p>=0,05). When the Celalux 3 was used, there was a statistically significant difference between the central and external regions (p<0,05). The hardness results obtained with the specimen made using the matrix of human tooth showed statistically significant differences between the 10 and 20 second photoactivation times (p<0,05). The factor composite resin also influenced the results. There was a statistically significant difference between the center and the mesial and distal regions when all the light curing units were used (p<0,05). There was also a statistically significant difference between the values measured on the mesial and distal boxes of the specimen (p<0,05). The light transmission results showed that little violet light reaches the bottom of the specimens and the position and the light curing unit\'s tip diameters influence the irradiance of light that reaches the bottom of the proximal boxes of MOD restorations. The light curing units showed different characteristics and they, associated to different photoativation protocols, influence the hardness of bulk fill composite resin restorations.
180

Comparação de diferentes pré-tratamentos de superfície na remineralização de esmalte com flúor em tratamento de lesões com mancha branca e sua resistência após desafio ácido / Comparison of different pretreatments on remineralization of enamel white spot lesions with fluoride and its resistance after new acidic challenge

Diana Ferreira Gadêlha de Araújo 03 June 2016 (has links)
A aplicação de flúor tópico é a principal estratégia de natureza química para a remineralização de lesões incipientes (LI) clinicamente visíveis como manchas brancas (MB) por cárie. Abordagens para aumentar a retenção de F no substrato pode favorecer sua ação e para isso, tratamentos prévios da superfície do esmalte podem ser usados. O objetivo deste trabalho foi comparar a capacidade de remineralização do flúor sem e com pré-tratamento do esmalte com ácido fosfórico e nitrato de alumínio e a sua resistência após novo desafio. Sessenta espécimes de esmalte bovino foram preparados (6mm x 4mm) e selecionados por meio de análise de microdureza de superfície (MS). LI foram produzidas através de ciclagem Desmineralização-Remineralização (DES-RE) e os espécimes divididos aleatoriamente em cinco grupos, de acordo com o tratamento (n=12): V- controle (verniz de fluoreto de sódio 5% por 4 horas), F (sem pré-tratamento); P-F(condicionamento ácido com ácido fosfórico por 30s); Al-F (nitrato de alumínio a 0,05M por 1min); P-Al-F (condicionamento com ácido fosfórico a 37% + nitrato de alumínio a 0,05M). Os tratamentos foram repetidos semanalmente durante quatro semanas. Após o tratamento, os espécimes foram submetidos à nova ciclagem ácida. Após cada etapa, nova MS foi realizada e ao final das análises, um corte transversal dos espécimes foi realizado. Uma das metades foi submetida à análise da microdureza longitudinal (ML) e a outra preparada para realização da microrradiografia transversal (TMR) para a análise de conteúdo mineral perdido. O percentual de perda de dureza de superfície (%PDS) foi analisado por ANOVA a 2 critérios de medidas repetidas e Tukey e o percentual de perda de dureza longitudinal (%PDL) por ANOVA a 3 critérios de medidas repetidas e Tukey (p<0,05). Os dados de TMR no parâmetro LD (profundidade da lesão) foram analisados por ANOVA a dois critérios (p<0,05). Os resultados mostraram que a ciclagem DES-RE resultou em significante %PDS e %PDL em todos os grupos. Grupo F revelou menor perda de MS após tratamento e, F, Al-F e P-Al-F, mostraram menor perda de dureza final, após o novo desafio ácido. Na análise de %PDL, o grupo V apresentou menor perda de dureza final quando comparado com os demais grupos, nas diferentes profundidades. A análise do conteúdo mineral não revelou nenhuma diferença entre os tratamentos e fases. Nenhum dos pré tratamentos propostos foram capazes de otimizar a atuação do gel APF na remineralização de MB. / The topical fluoride is the main chemical strategy to remineralize incipient caries lesions (ICL) visible as carious white spot lesions (WSL). Approaches to increase the fluoride retention may favor its action and therefore, enamel pretreatments can be used for this purpose. The aim of this study was to compare the potential of fluoride remineralization with and without previous enamel pretreatment with aluminum nitrate and phosphoric acid as well as their resistance after a new acid challenge. Sixty bovine enamel specimens were prepared (6mm x 4mm) and selected by the surface hardness (SH) analysis. The ICL were produced using DE-RE cycling and the specimens were randomized in five groups, according to the treatment (n=12): Vcontrol (5% sodium fluoride varnish during 4h), and four groups previously preatreated with topical application of acidulated phosphate fluoride (APF) during 4min: F (without pretreatment), P-F (phosphoric acid etching during 30s), Al-F (0.05M aluminum nitrate during 1min); P-Al-F (phosphoric acid etching + aluminum nitrate). The treatments were performed weekly during four weeks. After the treatment, the specimens were submitted to the new acid challenge. After each step, a new SH analysis was performed followed by the transversal cut of the specimens. A half was submitted to the longitudinal cross-sectional hardness analysis (LH) and the other half was prepared to transverse microradiography assessments (TMR) to determine the loss of mineral content. The percentage of surface mineral loss (%SH) was analyzed using two-way repeated-measures ANOVA and the percentage of crosssectional mineral loss (%LH) by the three-way repeated-measures ANOVA and Tukey (p<0.05). Data of TMR analysis by LD (lesion depth) parameter was analyzed with two-way ANOVA (p<0.05). The results showed significant %SH and %LH after DE-RE cycling for all groups. F group showed the lowest %SH after treatment, with no significant difference to Al-F and P-Al-F after the new acid challenge. V group showed the lowest %LH compared to the other groups, in the different depths, suggesting more resistance. Mineral content assessment did not reveal any difference among treatments and phases. None pretreatments were able to increase the potential of fluoride remineralization.

Page generated in 0.0456 seconds