• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 334
  • 16
  • 9
  • 9
  • 9
  • 9
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 359
  • 248
  • 94
  • 80
  • 69
  • 56
  • 54
  • 54
  • 51
  • 51
  • 50
  • 44
  • 43
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Avaliação de propriedades físico-químicas de compósitos resinosos bulk-fill = Evaluation of physicochemical properties of bulk-fill composite resins / Evaluation of physicochemical properties of bulk-fill composite resins

Marin Fronza, Bruna, 1990- 27 August 2018 (has links)
Orientador: Marcelo Giannini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T12:22:23Z (GMT). No. of bitstreams: 1 MarinFronza_Bruna_M.pdf: 2159343 bytes, checksum: 39b3c9ade2395da11c531548d34be71d (MD5) Previous issue date: 2014 / Resumo: Os objetivos no presente estudo foram: (1) caracterizar o conteúdo inorgânico; (2) investigar a passagem de luz (PL) através de incrementos com diferentes espessuras; (3) avaliar a resistência à flexão biaxial (RFB) e módulo de elasticidade (MO) em função da profundidade de polimerização; (4) verificar o grau de conversão (GC) e microdureza (MD) e (5) correlacionar a tensão de polimerização (TP) com a formação de fenda marginal (FM) em cavidades classe I com materiais restauradores bulk-fill, comparando com um compósito resinoso tradicional. Quatro resinas bulk-fill foram avaliadas: Surefill SDR flow (SDR), Filtek Bulk Fill (FBF), Tetric EvoCeram Bulk Fill (TEC) e EverX Posterior (EXP). Herculite Classic (HER) foi utilizada como controle. Para a caracterização da morfologia e composição do conteúdo inorgânico, uma porção de cada material foi imersa em solventes para remoção da matriz resinosa e posteriormente analisada por EDX e MEV. A PL foi mensurada através de diferentes espessuras dos materiais (1, 2, 3 e 4 mm) utilizando radiômetro acoplado a esfera integrada (n=5). Para o teste de RFB e MF, discos de resina composta (0,5 mm de espessura) foram confeccionados em um conjunto de matrizes sobrepostas (n=8), simulando profundidade de polimerização de 4 mm. O GC obtido por espectroscopia Confocal Raman e MD Knoop foram determinados em cavidades classe I com 4 mm de profundidade, as quais foram restauradas com as resinas e respectivos adesivos (n=5). A partir dessas restaurações foram confeccionadas réplicas em resina epóxi para análise de formação de FM em MEV. A TP de cada material foi determinada por um extensômetro associado a uma máquina de ensaio universal (n=5). As partículas de carga das resinas bulk-fill apresentaram formato irregular, esferoidal ou cilíndrico de tamanhos variados, de 0,1 ?m a 1 mm. Quanto a composição os principais elementos químicos identificados foram alumínio, bário e silício. Todos os materiais demonstraram menor passagem de luz com o aumento da espessura. Não houve diferença entre a PL para as resinas bulk-fill, porém apenas a SDR permitiu maior PL que HER. A atenuação da luz, entretanto, não teve influencia na RFB das resinas bulk-fill, enquanto para HER na maior profundidade houve redução da RFB. Embora, o MO ainda foi maior para HER. O GC foi uniforme em termos de profundidade para os materiais SDR, FBF e HER aplicado em incrementos. De modo contrário, os materiais TEC, EXP e HER em incremento único tiveram diminuição do GC com o aumento da profundidade. Para o teste de MD, resultados inferiores com o aumento da profundidade foram encontrados apenas para TEC, assim não houve correlação entre as análises de MD e GC. Com relação a TP, EXP apresentou os valores mais altos, enquanto TEC os menores. Correlação positiva foi detectada entre TP e formação de FM, as quais variaram entre os materiais. A técnica incremental demonstrou reduzir a FM para HER, SDR e TEC tiveram comportamento comparável a essa técnica convencional. As resinas bulk-fill apresentaram variações nos resultados, algumas demonstraram resultados semelhantes ou superiores à resina controle, podendo ser uma opção para os tradicionais procedimentos restauradores diretos / Abstract: The aims of this study were: (1) to characterize the inorganic content; (2) investigate light transmission (LT) through different thicknesses increments; (3) assess biaxial flexural strength (BFS) and modulus (MO) according to depth of cure; (4) verify degree of conversion (DC) and microhardness (MH) and (5) correlate polymerization stress (PS) and gap formation (GF) in class I cavities of bulk-fill restorative materials, compared to a regular composite resin. Four bulk-fill composites were tested: Surefill SDR flow (SDR), Filtek Bulk Fill (FBF), Tetric EvoCeram Bulk Fill (TEC) and EverX Posterior (EXP). Herculite Classic (HER) was used as control. To morphological and composition characterization of inorganic content, a portion of each material was immersed in solvents to remove resin matrix and then analyzed by energy-dispersive X-ray and scanning electron microscopy. The LT was measured through different material thicknesses (1, 2, 3 and 4 mm) by a laboratory-grade spectral radiometer spectroradiometer (n=5). To BFS and MO tests, discs (0.5 mm thick) were fabricated using a set of eight molds, to simulate polymerization depth of 4 mm. DC obtained by Confocal Raman spectroscopy and Knoop MH were measured in 4 mm depth class I cavities, which were placed with the composites and it respective adhesives (n=5). PS was determined for each material by an extensometer attached to a universal testing machine (n=5). Filler particles of bulk-fill composites presented irregular, spherical or cylindrical shape, which size varied from 0.1 ?m to 1 mm. Regarding composition analysis, aluminum, barium and silicon were identified in all composites. All materials demonstrated lower LT with increased increment thickness. No differences were found in translucency among bulk-fill composites, only SDR had higher light transmission than HER. However, light attenuation did not influence BFS of bulk-fill composites, while HER presented decreased BFS at deeper layers. Nevertheless, HER still had the highest MO. DC was uniform among depths for SDR, FBF and HER applied incrementally. Conversely, TEC, EXP and HER bulk-filling presented a decrease in DC with increased depth. To MH test, lower results with increased depth were detected only for TEC, indeed there was no correlation between DC and MH analyzes. Regarding PS, EXP had the highest values, whilst TEC the lowest ones. Positive correlation was detected between PS and GF, which varied according to materials. Incremental filling technique reduced GF percentage to HER, and only SDR and TEC had comparable results to this conventional technique. Some of the bulk-fill composites presented similar or superior outcomes compared to control, which may be an option for traditional direct restorative procedures / Mestrado / Dentística / Mestra em Clínica Odontológica
202

Influência do preaquecimento nas propriedades físicas de agentes cimentantes fotoativados através de diferentes espessuras de cerâmica = Influence of pre-heating on the physical properties of luting agents photoactivated through different ceramic thicknesses / Influence of pre-heating on the physical properties of luting agents photoactivated through different ceramic thicknesses

Lima, Michele de Oliveira, 1991 28 April 2015 (has links)
Orientador: Flávio Henrique Baggio Aguiar / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T16:00:43Z (GMT). No. of bitstreams: 1 Lima_MicheledeOliveira_M.pdf: 1194610 bytes, checksum: 09e2b8319999015738ccee35c170ebb8 (MD5) Previous issue date: 2015 / Resumo: O propósito deste estudo "in vitro" foi avaliar a influência do preaquecimento e ativação de agentes de fixação através de blocos cerâmicos sobre suas propriedades físicas. Para tanto, os agentes cimentantes RelyX Arc (RXA; 3M/ESPE), RelyX Ultimate (RXU; 3M/ESPE), RelyX Veneer (RXV; 3M/ESPE) e Filtek Z350 Flow (FLK; 3M/ESPE) foram manipulados com diferentes temperaturas (23ºC ou 54ºC), inseridos em matrizes de silicone específicas (cilíndricas: 5x0,5mm ou ampulheta: 0,5mm de espessura, 8mm de comprimento, 4mm de largura e 1,5mm de constrição, de acordo com a metodologia dos testes realizados) e fotoativados sob discos cerâmicos de dissilicato de lítio (IPS e.max; Ivoclar Vivadent, Barueri, SP, Brasil), cor A2, nas espessuras de 0,75mm ou 1,5mm.?A fotoativação foi realizada posicionando a extremidade do aparelho fotoativador sobre o disco cerâmico, para tal foi utilizado o LED Bluephase 16i (Vivadent, B?rs, Austria), com irradiância de 1519 mW/cm², por 40 segundos. Foram confeccionadas 128 amostras cilindricas (n=8) e realizados os testes de grau de conversão (GC) por meio da espectroscopia FT-IR. Estes mesmos espécimes foram levados ao microdurômetro para a mensuração da dureza Knoop (DK) na superfície de topo e logo após, foram imersos em solução de álcool absoluto por 24 h, e então foi realizada uma nova leitura de DK para a obtenção do percentual de redução de dureza e mensuração indireta da densidade de ligações cruzadas (DLC) dos materiais. Foram confeccionadas novas amostras em formato de ampulheta (n=8) que foram utilizadas para o teste de resistência coesiva à tração (RCT), realizado em máquina de ensaio universal. Para os testes de sorção de água (SA) e solubilidade (S) dos agentes de fixação, foram necessários novos espécimes cilíndricos (n=8) que foram pesados em balança analítica até obtenção de massa constante. Os dados foram analisados utilizando-se ANOVA três fatores e teste de tukey (?=0,05). Com relação às espessuras de cerâmica testadas, a menor espessura de cerâmica proporcionou maiores valores de DK (p=0.027). A menor temperatura (23°C) proporcionou maiores valores de SA (p=0.0229) e S (p=0.0257). Também houve diferença estatística para o fator cimento, sendo que para GC, RXA apresentou os maiores valores, seguido dos agentes cimentantes RXV, RXU e FLK. Para o teste de DK e DLC, RXU apresentou os maiores valores, seguido de RXA, RXV e FLK. Para o teste de RCT, RXA apresentou os maiores valores, seguido por RXV, RXU e FLK. Para SA e S, RXV apresentou os maiores valores, seguido por RXA, RXU e FLK. Pode-se concluir que o preaquecimento diminuiu nos resultados de sorção de água e solubilidade; a maior espessura de cerâmica diminuiu apenas a microdureza superficial, e que as propriedades físicas dos materiais são dependentes da composição dos mesmos / Abstract: The purpose of this "in vitro" study was to evaluate the influence of preheating on the physical properties of a luting agent photoactivated through ceramic discs. The cements: RelyX Arc (RXA, 3M / ESPE), RelyX Ultimate (RXU; 3M / ESPE), RelyX Veneer (RXV; 3M / ESPE), and Filtek Z350 Flow (FLK; 3M / ESPE) were manipulated using different temperatures (23°C or 54°C), inserted in specific silicone matrices (cylindrical: 5x0.5mm or hourglass: thickness 0.5 mm, 8 mm in length, 4mm wide and a 1.5mm constriction, according to the methodology of testing) and photoactived under lithium disilicate ceramic discs (IPS e.max, Ivoclar Vivadent, Barueri, SP, Brazil) color A2, in thicknesses of 0.75 mm or 1.5 mm. Photoactivation was carried out by positioning the end of the curing unit on the ceramic disk. A Bluephase 16i (Vivadent, B?rs, Austria), with an irradiance of 1519 mW / cm2, was used for 40 seconds to cure the specimens. One hundred twenty-eight cylindrical samples were prepared (n=8) and the degree of conversion tests (DC) were performed using FT-IR spectroscopy. The samples were taken to a Knoop hardness tester (KHN) for microhardness testing on the top surface. After the initial testing, the specimens were dipped in absolute ethanol solution for 24 h, and then a new KHN reading was performed to obtain the hardness reduction percentage and the crosslink density (CLD) indirect measurement of the material. New samples were prepared with an hourglass shape (n=8) and were used for the ultimate tensile strength (UTS) testing, performed in a universal testing machine. For the water sorption test (WS) and solubility (S) of the luting agents, new cylindrical specimens (n=8) were required which were weighed on an analytical balance until a constant mass was obtained. The data was analyzed using three-way ANOVA and Tukey¿s test (?=0.05). Regarding the tested ceramic thicknesses, the thinnest ceramic gave higher values of KHN (p=0.027). The lowest temperature (23°C) gave higher S (p=0.0257) and WS (p=0.0229) values. There was also a statistically significant difference for cement factor, where RXA showed the highest values for DC, followed by RXV, RXU and FLK. For the KHN and CLD tests, RXU showed the highest values, followed by RXA, RXV and FLK. For the UTS test, RXA showed the highest values, followed by RXV, RXU and FLK. For WS and S, RXV showed the highest values, followed by RXA, RXU and FLK. It can be concluded that pre-heating decreased the results of water sorption and solubility; the biggest ceramic thickness decreased only superficial microhardness, and the physical properties of the material are dependent on the composition thereof / Mestrado / Dentística / Mestra em Clínica Odontológica
203

Manufatura e caracterização de ligas de alumínio-cobre (Duralumínio) fabricadas via técnicas de metalurgia do pó

SILVA, Tarsila Tenorio Luna da 22 June 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-09-27T20:17:57Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Tarcila Tenório Luna da Silva.pdf: 8200158 bytes, checksum: 8cb4590deb12775b0cc56ff01b3a0dee (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-11-19T21:03:20Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Tarcila Tenório Luna da Silva.pdf: 8200158 bytes, checksum: 8cb4590deb12775b0cc56ff01b3a0dee (MD5) / Made available in DSpace on 2018-11-19T21:03:21Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Tarcila Tenório Luna da Silva.pdf: 8200158 bytes, checksum: 8cb4590deb12775b0cc56ff01b3a0dee (MD5) Previous issue date: 2017-06-22 / Este trabalho consiste no estudo de duas ligas de alumínio, AA2011 e AA2014, conhecidas por Duralumínio, fabricadas através da metalurgia do pó. Para tanto foram fabricadas diversas amostras com quantidades de Al-Cu distintas, são elas Al4%Cu, Al4,5%Cu, Al5%Cu, Al5,5%Cu e Al6%Cu. Os pós elementares utilizados foram o Alumínio AA1100 da marca Alcoa Inc., foi realizada a Espectrometria de Fluorescência de Raios-X deste que obteve como resultado uma pureza superior à 99%. O Cobre utilizado foi da marca Dinâmica Química Contemporânea Ltda. Primeiramente, as amostras foram processadas em um moinho de alta energia do tipo SPEX nos tempos de 0,5; 1 e 2 horas. Foram feitas Difrações de Raios-X destas amostras com intuito de investigar a presença de fases endurecedoras como a fase Al2Cu da liga. As amostras processadas por 2 horas e uma amostra de Al AA1100 foram compactadas uniaxialmente a frio em uma pressão hidráulica e então sinterizadas em um forno tipo mufla com atmosfera de nitrogênio (N2). Foram feitos testes de microdureza Vickers nestas amostras e identificado que o aumento da dureza é diretamente proporcional a quantidade de Cobre contida na amostra. A liga de Al6%Cu apresentou um aumento de dureza de 184,89% enquanto a amostra Al5%Cu apresentou 168,98%. Para completar a caracterização das ligas, análises de Microscopia Ótica, Microscopia Eletrônica de Varredura com Espectroscopia de Baixa Energia Dispersiva associada foram realizados. / This work studied two Aluminum’s alloys, AA2011 and AA2014, knew by Duralumin, manufactured by powder metallurgy techniques. For that, samples with different quantities of Al-Cu were manufactured, they are Al4%Cu, Al4,5%Cu, Al5%Cu, Al5,5%Cu e Al6%Cu. The raw powder used were the Aluminum AA1100 from Alcoa Inc., this work shows X-Ray Fluorescence Spectrometer of it which obtained a purity superior of 99% as result. A Dinâmica Química Contemporânea Ltda Cooper powder as used. First, the samples were processed in a SPEX shaker mills for 0.5; 1 e 2 hours. X-Ray diffraction of these samples was done with the purpose of investigation of hardening phases such as the compound Al2Cu. The samples processed for 2 hours and a sample of Al AA1100 were one-axial cold pressed in a hydraulic press machine, so sintered in a Muffle type furnace under nitrogen (N2) atmosphere. Micro Vickers hardness tests in theses samples were procedures and identified that the hardness increase is directly proportional with Copper quantities in the sample. Al6%Cu sintered alloy showed a hardness increase of 184.89% while Al5%Cu sintered alloy showed 168.98%. For the alloy’s complete characterization, analyses of Optical Microscopy (OM), Scanning Electron Microscopy (SEM) plus Low Energy Dispersive Spectroscopy (EDS) associate were realized.
204

Detecção de erosão dental utilizando análise de espalhamento de luz coerente - speckle / Detection dental erosion using coherent light scattering analysis - speckle

Koshoji, Nelson Hideyoshi 01 December 2014 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2016-05-19T17:43:26Z No. of bitstreams: 1 Nelson Hideyoshi Koshoji.pdf: 1555158 bytes, checksum: edeadb5cae29044249dc96c8e2bbee65 (MD5) / Made available in DSpace on 2016-05-19T17:43:26Z (GMT). No. of bitstreams: 1 Nelson Hideyoshi Koshoji.pdf: 1555158 bytes, checksum: edeadb5cae29044249dc96c8e2bbee65 (MD5) Previous issue date: 2014-12-01 / Dental erosion is a non-carious cervical lesion that is related to progressive tooth loss through its contact with chemicals that dissolve the enamel hydroxyapatite crystals. Currently, it is a highly prevalent condition among individuals of all ages. The loss of the structure of this tissue causes changes in the roughness of the surface. The objective of this work is to develop a methodology to identify and quantify this injury, in a non-invasively and non-destructive way, with low cost and executed in real time by analyzing the coherent light scattering patterns, called speckle. It was used 32 samples of bovine incisors and they were divided into 4 groups with different times of acid etching. Half of each sample was protected and then immersed in Coke (pH ≅ 2.5) for 10, 20, 30 and 40 min, twice daily and for 7 consecutive days. Each sample has two areas: half healthy and half eroded. After the challenge, the samples were submitted to speckle analysis to find the relative differences between the two regions in each group. It was found 10 min with 18% 20 min with 24% 30 min with 38% and 40 min with 44% of relative difference. After this analysis, we performed also a Knoop hardness test in order to compare methods. There was a linear trend between the methods with coefficient r = 0.80. The speckle image is proportional to the attack time, has a strong correlation and a good agreement with the Knoop hardness test. / A erosão dental é uma lesão cervical não cariosa que está relacionada a perda progressiva do dente através do seu contato com substâncias químicas que dissolvem os cristais de hidroxiapatita do esmalte. Atualmente, é uma condição altamente prevalente entre indivíduos de todas as idades. A perda da estrutura deste tecido provoca alterações na rugosidade de sua superfície. O objetivo deste trabalho é desenvolver uma metodologia que identifique e quantifique essa lesão de forma não invasiva, não destrutiva, com baixo custo e executado em tempo real através da análise dos padrões de espalhamento da luz coerente, denominado speckle. Foram utilizadas 32 amostras de incisivos bovinos e dividida em 4 grupos com diferentes tempos de ataque ácido. Metade de cada amostra foi protegida e, em seguida, imersas em coca-cola (pH ≅ 2,5) durante 10, 20, 30 e 40 min, duas vezes ao dia e 7 dias consecutivos. Cada amostra possui duas áreas: metade saudável e metade erodida. Após o desafio, as amostras foram submetidas à análise speckle para encontrar as diferenças relativas entre as duas regiões de cada grupo. Foi encontrado 10 min com 18%, 20 min com 24%, 30 min com 38% e 40 min com 44% de diferença relativa. Após esta análise, foram realizados, também, o teste de dureza Knoop afim de comparar os métodos. Houve uma tendência linear entre os métodos com coeficiente r = 0.80. A imagem speckle é proporcional ao tempo de ataque, possui uma forte correlação e uma boa concordância com o teste de dureza Knoop.
205

Comparación in vitro de la microdureza y rugosidad del cerómero antes y después de su exposición a una bebida energizante

Hidalgo Acuña, Nataly Celia 29 January 2020 (has links)
Objetivo: Comparar in vitro la microdureza y rugosidad superficial del cerómero antes y después de su exposición a una bebida energizante. Materiales y métodos: Este estudio fue de tipo experimental in vitro. Se evaluaron 20 discos tipo cilíndricos (6 mm de altura y 4 mm de ancho) del cerómero SR Adoro® divididos en dos grupos para evaluar la microdureza superficial y rugosidad superficial. El desafío erosivo se realizó por 30 minutos/1 vez/ 5 días con la bebida Red Bull®. El análisis estadístico que se utilizó para evaluar la microdureza superficial fue la prueba de Wilcoxon. Sin embargo, para evaluar la rugosidad superficial se utilizó la prueba de T Student. Resultados: Se encontraron diferencias estadísticamente significativas al evaluar la microdureza superficial. Sin embargo, no se encontraron diferencias significativas al evaluar la rugosidad superficial del cerómero. La media y desviación estándar de la microdureza superficial del cerómero SR Adoro® antes del desafío erosivo fue de 55.45 + 6.42 MPa y después del desafío erosivo fue de 38.24 + 6.09 MPa. La diferencia de microdureza superficial inicial y final fue de 17.21+ 0.33 MPa. La media y desviación estándar de la rugosidad del cerómero SR Adoro® antes del desafío erosivo fue de 1.66 + 0.30 y después fue de 1.703 + 0.43 µm. La diferencia de rugosidad inicial y final del cerómero SR Adoro® expuesta a la bebida (Red Bull®) fue de 0.04+ 0.33 µm. Conclusiones: Existen diferencias estadísticamente significativas al evaluar la microdureza superficial. Sin embargo, no se encontraron diferencias estadísticamente significativas al evaluar la rugosidad del cerómero SR Adoro® (p<0.05; p=0.808) al ser expuesta a una bebida energizante Red Bull®. / Objective: To compare in vitro the superficial microhardness and roughness of the ceromer before and after being exposed to an energizing drink. Materials and methods: This study was of experimental type in vitro. Twenty cylindrical discs (6 mm high and 4 mm wide) of the SR Adoro® ceromer were divided into two groups to evaluate the surface microhardness and surface roughness. The erosive challenge was performed for 30 minutes / 1 time / 5 days with the Red Bull® drink. The statistical analysis that was used to evaluate the surface microhardness was the Wilcoxon test. However, the Student's T test was used to evaluate the surface roughness. Results: Statistically significant differences were found when evaluating surface microhardness. However, no significant differences were found when evaluating the roughness of the ceromer. The mean and standard deviation of the surface microhardness of the SR Adoro® ceromer before the erosive challenge was 55.45 + 6.42 MPa and after the erosive challenge was 38.24 + 6.09 MPa. The difference of initial and final surface microhardness was 17.21 + 0.33 µm. The mean and standard deviation of the rugosity of the SR Adoro® ceromer before the erosive challenge was 1.66 + 0.30 µm and then was 1.703 + 0.43 µm. The initial and final roughness difference of the SR Adoro® ceromer exposed to the beverage (Red Bull®) was 0.04 + 0.33 µm. Conclusions: There are statistically significant differences when evaluating surface microhardness. However, no statistically significant differences were found when assessing the rugosity of the SR Adoro® ceromer (p<0.05, p = 0.808) when exposed to a Red Bull® energy drink. / Tesis
206

Cuestiones procesales pendientes de la Ley no. 19.947 sobre matrimonio civil relativas al divorcio por cese de convivencia

Montoya Urra, Karla Kristy January 2019 (has links)
Memoria para optar al grado de Licenciada en Ciencias Jurídicas y Sociales / Con la introducción del divorcio vincular en nuestro ordenamiento por la Ley Nº 19.947 que establece la Nueva Ley de Matrimonio Civil, surgen interrogantes relativas a ciertos aspectos procesales de aquella institución, las cuales se encuentran pendientes al no existir una respuesta unánimemente aceptada todavía. Tres son las cuestiones procesales que aquí se revisan, todas en relación al divorcio por cese de convivencia. Primero, se analizará la limitación impuesta a los matrimonios celebrados bajo la vigencia de la referida ley para acreditar el cese de su convivencia, la cual pugna con el derecho a la prueba y el principio de libertad probatoria en materia de Familia al establecerse la taxatividad de medios de prueba. En segundo lugar, se tratará la naturaleza jurídica del divorcio solicitado de común acuerdo, esto es, si corresponde a un acto judicial contencioso o a uno no contencioso, adaptándose mejor a esta última figura al destacarse la ausencia de contienda entre partes, sin perjuicio de la jurisprudencia que le atribuye un carácter contradictorio. Finalmente, me referiré a la naturaleza jurídica de la denominada cláusula de dureza, en particular, si debe ser entendida como una excepción perentoria o un presupuesto procesal de la acción de divorcio, siendo la primera alternativa más armónica con el tenor literal de la ley, además de ser reconocida como tal por la doctrina y la jurisprudencia
207

Evaluación in vitro de la microdureza de esmalte y dentina de dientes de bovino expuestos a tres bebidas isotónicas

Salazar Salazar, Iris Sarela 12 May 2015 (has links)
Introduction: Isotonic drinks can cause dental tissue demineralization, which can be measured using Vickers microhardness test to evaluate their erosive effects. Aim: This in vitro study is aimed at evaluating microhardness of enamel and dentin of bovine teeth exposed to isotonic drinks. Materials and Methods: Sixty (60) specimens, thirty (30) enamels and thirty (30) bovine dentins were selected and divided into 6 groups: G1: Gatorade® Perform2/enamel, G2: Electrolight®/enamel, G3: Powerade® ION4/enamel, G4: Gatorade® Perform2/dentin, G5: Electrolight®/dentin, and G6: Powerade® ION4/dentin. These were subjected to the erosive challenge with isotonic drinks for five-minute periods, three times a day for five days. In order to evaluate the surface microhardness, the Vickers method was used with loads of 100g for 15 seconds on the enamel and 50g for 15 seconds on the dentin, before and after being exposed to the acid action of the isotonic drinks. Data was analyzed applying Student’s t-test and Wilcoxon test for the bivariate analysis, while the ANOVA and Kruskal Wallis tests were used for the multivariate analysis. Results: After comparing the initial and final microhardness values of the specimens, we found a significant statistical difference (p≤0.05): G1 (322.38±4.23 kg/mm2 / 170.60±25.05 kg/mm2); G2 (322.26±4.93 kg/mm2 / 181.73±8.75 kg/mm2); G3 (322.51±3.32 kg/mm2/189.03±18.24 kg/mm2); G4 (53.70±11.83 kg/mm2 / 25.79±9.36 kg/mm2); G5 (52.05±13.06 kg/mm2 / 25.83±9.87 kg/mm2); and G6 (51.81±11.89 kg/mm2 / 26.25±11.46 kg/mm2). No significant statistical difference was found by comparing the erosive effect of the three selected isotonic drinks. Conclusion: The in vitro erosive challenge with isotonic drinks causes reduction in enamel and dentin microhardness. However, no significant difference was found by comparing the erosive effect of the three isotonic drinks on the enamel and dentin. / Introducción: Las bebidas isotónicas son capaces de producir desmineralización en el tejido dental y, mediante el método de microdureza Vickers, se puede evaluar su efecto erosivo. Objetivo: El propósito de este estudio in vitro fue evaluar la microdureza de esmalte y dentina de dientes de bovino expuestos a tres bebidas isotónicas. Material y Métodos: Se utilizaron sesenta especímenes (treinta esmaltes y treinta dentinas de bovino), divididos en seis grupos: G1: Gatorade® Perform2/esmalte, G2: Electrolight®/esmalte, G3: Powerade® ION4/esmalte, G4: Gatorade® Perform2/dentina, G5: Electrolight®/dentina y G6: Powerade® ION4/dentina. Estos fueron expuestos al desafío erosivo de las bebidas isotónicas por un periodo de cinco minutos, tres veces al día, durante cinco días. Para evaluar la microdureza superficial, se utilizó el método Vickers, con cargas de 100g por 15 segundos, para el esmalte; y 50g por 15 segundos, para la dentina; antes y después de ser sometidos a la acción ácida de las bebidas. Los datos fueron analizados mediante las pruebas t de Student y Wilcoxon para el análisis bivariado y para el análisis multivariado, las prueba ANOVA y Kruskal Wallis. Resultados: Se encontraron diferencias estadísticamente significativas al comparar los valores de microdureza inicial y final de los especímenes (p≤0.05): G1 (322.38±4.23 kg/mm2 / 170.60±25.05 kg/mm2); G2 (322.26±4.93 kg/mm2 / 181.73±8.75 kg/mm2); G3 (322.51±3.32 kg/mm2/189.03±18.24 kg/mm2); G4 (53.70±11.83 kg/mm2 / 25.79±9.36 kg/mm2); G5 (52.05±13.06 kg/mm2 / 25.83±9.87 kg/mm2); G6 (51.81±11.89 kg/mm2 / 26.25±11.46 kg/mm2). En cambio, no se encontraron diferencias estadísticamente significativas al comparar el efecto erosivo entre las tres bebidas isotónicas. Conclusión: El desafío erosivo in vitro por bebidas isotónicas causa disminución en la microdureza del esmalte y dentina. Sin embargo, no existen diferencias significativas al comparar el efecto erosivo de las tres bebidas isotónicas en el esmalte y dentina. / Tesis
208

Efeito de materiais contendo compostos bioativos na remineralização de lesões de erosão no esmalte bovino: estudo in vitro / Effect of materials with bioactive compounds on remineralization of bovine enamel with erosion lesions: in vitro study

Pedrosa, Simone Soares 25 October 2013 (has links)
A erosão dentária ocasiona a perda da estrutura dental através da dissolução da sua porção mineralizada por ácidos de origem não bacteriana. Assim, o objetivo deste estudo é avaliar a capacidade de materiais contendo compostos bioativos de remineralizar o esmalte bovino submetido a desafio erosivo e se o método de quantificação da fluorescência induzida por luz (QLF) tem correlação com os resultados do teste de microdureza Knoop. 120 fragmentos de esmalte bovino foram distribuídos entre os grupos experimentais, sendo n=5 para o teste de microdureza (3 x 3 x 2 mm) e n=10 para o método do QLFTM (5 x 5 x 3 mm). Os corpos-de-prova foram analisados em três momentos diferentes (inicial, após 2 dias de protocolo de erosão e após 6 dias de tratamento remineralizador). As amostras foram submetidas a 2 dias de protocolo de erosão, através de imersão em ácido cítrico a 0,3% pH 3,2, por 2 minutos e manutenção das mesmas em saliva artificial (pH 7,0) durante 24 horas. Na sequência, foram realizados os tratamentos remineralizadores por 6 dias consecutivos: 1 gota de saliva foi depositada sobre as amostras e após 1 hora foram imersas por 2 minutos em suspensão aquosa preparada com os seguintes materiais: G1-Pro-Argin+NaMFP, bicarbonato de arginina + carbonato de cálcio + monofluorfosfato de sódio (Colgate® Sensitive Pró-Alívio); G2-Recaldent+NaF, fosfopeptídeo de caseína com fosfato de cálcio amorfo + fluoreto de sódio (MI Paste Plus); G3-ACP+NaF, fosfato de cálcio amorfo + fluoreto de sódio + nitrato de potássio (Relief ACP); G4-CaGP+KF, glicerofosfato de cálcio + fluoreto de potássio (Flúor Protector Gel); G5-NovaMin®+NaF, fosfosilicato de cálcio e sódio + fluoreto de sódio (Nupro® Sensodyne®); G6-NovaMin®+NaMFP, fosfosilicato de cálcio e sódio + monofluorfosfato de sódio (Sensodyne® Repair&Protect); G7-NaF, fluoreto de sódio + nitrato de potássio (Sensodyne® Cool Gel) e G8-saliva artificial (controle negativo). Após 2 horas de imersão em saliva foi repetido o protocolo de erosão. Foram realizadas análises estatísticas para o teste de microdureza e QLF (=0,05). A ANOVA de dois fatores para medidas repetidas mostrou diferenças estatisticamente significativas apenas para os momentos da análise e para a interação dos fatores tratamentos x momentos da análise. O teste de Tukey mostrou diferenças significativas na comparação entre todos os momentos da análise e na interação momentos da análise x tratamentos: valores iniciais x após erosão e após tratamento e entre os valores após erosão x após tratamento (NovaMin®+NaF, NovaMin®+NaMFP, NaF e saliva). O teste de Tukey na comparação dos tratamentos no momento final da análise mostrou diferenças significativas na análise da microdureza para o Recaldent+NaF x NovaMin®+NaF, NovaMin®+NaMFP e NaF; mas no QLF, as diferenças ocorreram entre o Pro-Argin+NaMFP x NaF e saliva; Recaldent+NaF x NovaMin®+NaMFP, NaF e saliva e ACP+NaF x NaF. Nenhum dos tratamentos foi capaz de remineralizar totalmente o esmalte dental, mas os materiais Pro-Argin+NaMFP, Recaldent+NaF, ACP+NaF e CaGP+KF foram capazes de estabilizar o processo de erosão do esmalte com resultado superior aos demais tratamentos. O método do QLF mostrou uma correlação positiva significativa com os resultados do teste de microdureza. / Dental erosion leads to loss of the tooth structure by dissolving its mineral portion by acids for non-bacterial origin. The objective of this study is evaluate the ability of materials with bioactive compounds to remineralize bovine enamel subjected to erosive challenge and verify the possible correlation between the datas from the quantitative light-induced fluorescence method (QLF) and the Knoop surface microhardness test. 120 bovine enamel pieces were distributed among experimental groups with n=5 for microhardness testing (3 x 3 x 2 mm) and n=10 for the QLF method (5 x 5 x 3 mm) and were analysed at three different times (initial, after 2 days of erosion protocol and after 6 remineralizing days of treatment).The samples were subjected to two-days erosion protocol, through its immersion into 0,3% citric acid solution pH 3,2 for 2 minutes and maintaining them into artificial saliva for 24 hours (pH 7,0). Following remineralizing treatments were performed for 6 consecutive days: the samples were covered with 1 drop of saliva and after 1 hour were immersed for 2 minutes in the slurry prepared with the following materials: G1-Pro-Argin+NaMFP, arginine bicarbonate + calcium carbonate + sodium monofluorophosphate (Colgate® Sensitive Pro-Alívio); G2-Recaldent+NaF, casein phosphopeptide-amorphous calcium phosphate + sodium fluoride (MI Paste Plus); G3-ACP+NaF, amorphous calcium phosphate + sodium fluoride + potassium nitrate (Relief ACP); G4-CaGP+KF, calcium glycerophosphate + potassium fluoride (Fluor Protector Gel); G5- NovaMin®+NaF, calcium sodium phosphosilicate + sodium fluoride (Nupro® Sensodyne®); G6-NovaMin®+NaMFP, calcium sodium phosphosilicate + sodium monofluorophosphate (Sensodyne® Repair&Protect); G7-NaF, sodium fluoride + potassium nitrate (Sensodyne® Cool Gel) and G8-Artificial saliva (negative control). After 2 hours of soaking in saliva the erosion protocol was repeated. Statistical analyzes were conducted for microhardness and QLF with coincidence of the results (=0,05). A two-factors ANOVA for repeated measures showed statistically significant differences only for the time of analysis and the interaction treatments x time of analysis. The Tukey test showed statistically significant differences when comparing the three times of analysis and the interaction between times of analysis x treatments: baseline values with values after erosion and after treatment and the values after erosion x after treatment (NovaMin®+NaF, NovaMin®+NaMFP, NaF and saliva). The Tukey test when comparing the treatments x final times of analysis showed statistically significant differences in microhardness test for Recaldent+NaF x NovaMin®+NaF, NovaMin®+NaMFP and NaF; in QLF method the differences occurs between Pro-Argin+NaMFP x NaF and saliva; Recaldent+NaF x NovaMin®+NaMFP, NaF and saliva; ACP+NaF x NaF. None of the treatments was able to completely remineralize bovine enamel, but Pro-Argin+NaMFP, Recaldent+NaF, ACP+NaF and CaGP+KF materials were able to stabilize the eroding enamel, thus demonstrating a score higher than others and the QLF method showed a significant and positive correlation with the microhardness test results.
209

"Viscoelasticidade em função dos modos de fotoativação de compósitos" / Viscoelasticity as a function of fotoactivation mode

Lazaro Filho, Milton 28 September 2004 (has links)
O escoamento viscoelástico pode contribuir ao alívio da tensão gerada durante a polimerização de compósitos aderidos em cavidades. O objetivo do estudo foi verificar a influência de dois modos de fotoativação contínua com diferentes intensidades (1000 mW/cm 2 e 250 mW/cm 2 ) e mesma densidade de energia final (24 J/cm 2 ) sobre propriedades viscoelásticas de dois compósitos comerciais (Filtek A110 e Herculite XRV) após a cura. Os parâmetros viscoelásticos avaliados foram: E’ (módulo de ar-mazenamento), tand (fator de perda) e as constantes reológicas t (tempo de relaxa-mento) e h (viscosidade).. Espécimes (50 x4 x 2 mm), de cada material em cada condição de fortoativação, (total de 51) foram confeccionados à temperatura ambiente e armazenados por 7 dias a 37 o C e submetidos então, a análise dinâmico-mecânica em aparelho DMA 242 (NETZSCH): varreduras de freqüência (50, 20, 10, 5, 2, 1 e 0,1 Hz) em ensaios isotérmicos (25 O C, 37 O C, 50 O C, 70 O C, 80 O C, 90 O C e Tg) em modo flexural (três pontos). Determinou-se também, a temperatura de transição vítrea (Tg). Os resultados de E’ e tand obtidos entre os 3 e os 7 minutos a cada temperatura permitiram a obtenção do módulo complexo E*. A aplicação do princípio de transposição tempo-temperatura de Williams-Landel-Ferry (TTS), resultou na curva mestra a 37 o C de E*(w). A aplicação de algoritmo de Laplace (RSI Orchestrator – Rheometrics), permitiu a obtenção da curva-mestra na mesma temperatura de E*(t). Através da aplicação do modelo matemático de Maxwell discretizado (n=10), obteve-se o espectro de relaxamento, que permitiu a obtenção de t e h de cada ma-terial em cada condição de fotoativação. Foi determinado também, em espécimes especialmente confeccionados para estas finalidades (n=3), o grau de conversão (GC) (análise de FTIR) e micro-dureza Knoop (KHN). Ambas propriedades foram analisadas antes (temperatura ambiente) e depois de tratamento térmico (aquecimento das amostras por 10 minutos a 110 o C). Os resultados do estudo permitiram concluir que: 1) Compósitos ativados com maior intensidade de luz produzem espécimes com menor t e h; 2) E’ e tand são significantemente afetados pelo aumento da intensidade da luz ativadora, diminuindo para Filtek A110 e aumentando para Hercu-lite XRV; 3) A Tg diminui com o aumento da intensidade para Filtek A110 e permanece inalterada para Herculite XRV; 4) Para Filtek A110, GC e KHN dos espécimes curados à temperatura ambiente não mudou com o aumento da intensidade, en-quanto que para Herculite XRV diminuiu; 5) GC e KHN melhoraram para Filtek A110 com o tratamento térmico adicional; para Herculite XRV, apenas KHN melhorou com o tratamento térmico, mas não o GC. / Viscoelastic flow may contribute to the stress relief generated during composites po-lymerization adhered in cavities. The aim of this study was to verify how two modes of continuous photoactivation with different intensities (1000 mW/cm 2 and 250 mW/cm 2 ) and same density of the final energy (24 J/cm 2 ) affect viscoelastic properties after cure of two commercial composites (Filtek A110 and Herculite XRV). The evaluated viscoelastic parameters were: E’ (storage modulus), tand (loss factor) and rheologic constraints t (relaxation time) and h (viscosity). Specimens (50 x4 x 2 mm), of each material at each photoactivation mode (totaled 51) were built at room tem-perature and have been stored for 7 days at 37 o C to undergo the dynamic-mechanical analysis in DMA 242 (Netzsch) equipment. Frequency sweep was made (50, 20, 10, 5, 2, 1 and 0,1 Hz) in each of the isothermic testing (25 O C, 37 O C, 50 O C, 70 O C, 80 O C, 90 O C and Tg) in flexural test (3 points). It was also determined glass transition temperature (Tg). The results of E’ and tand obtained between 3 and 7 min-utes at each temperature allowed to obtain complex modulus E*. The application of time-temperature switch principle of Williams-Landel-Ferry (TTS) ended up in master-curve of E*(w) at 37 o C. The use of the Laplace algorithm (RSI Orchestrator – Rheometrics) allowed to obtain the master curve (at same temperature) of E*(t). By means of the using of discretized Maxwell’s mathematical model (n=10), relaxation spectrum was obtained, which resulted in t and h of each of the materials in each of the photoactivation conditions. Degree of conversion (DC) (FTIR analysis) and Knoop microhardness (KHN) were also determined in specially made specimens for these purposes (n=3). Both properties were analyzed before (room temperature) and after thermal treatment (heating of the specimens for 10 minutes at 110 o C). The results of the study allowed to conclude that: 1) Composites activated with higher intensity yield lower t and h specimens; 2) E’ and tand are meaningfully affected by the increase of the activating light intensity, decreasing for Filtek A110 and increasing for Herculite XRV; 3) Tg decreases with the intensity increase for Filtek A110 and remains un-changed for Herculite XRV; 4) For Filtek A110, DC and KHN of the cured specimens at room temperature, remained unchanged with the intensity increase, while for Her-culite XRV they decreased; 5) DC and KHN raised for Filtek A110 with additional thermal treatment – for Herculite XRV, only KHN improved with thermal treatment, but there were no changes for DC.
210

Dureza da camada de adesivo e da camada híbrida e a sua relação com a resistência de união à dentina / Hardness of the adhesive layer and the hybrid layer and its relationship to bond strength to dentin

Nunes, Paula Mendes Acatauassú 02 September 2013 (has links)
Este estudo avaliou in vitro a dureza da camada de adesivo e da camada híbrida de uma interface entre resina composta e dentina humana por meio de ensaios de nanodureza (DUH). Foi avaliada a resistência de união por meio de testes de microcisalhamento (MC) com o objetivo de observar a relação desta resistência com a propriedade da dureza. Os fatores de variação compreendem quatro sistemas adesivos (Adper Scotchbond Multiuso, Adper Single Bond 2, Clearfil SE Bond e Single Bond Universal) e duas profundidades dentinárias (dentina rasa e dentina profunda). As unidades experimentais foram compostas por 144 fragmentos dentais obtidos da face vestibular de molares humanos, os quais foram distribuídos em 16 grupos, 8 grupos com n=6 para os ensaios de DUH e 8 grupos com n=12 para os ensaios de MC de forma que os quatro sistemas adesivos foram aplicados sobre fragmentos de dentina rasa e de dentina profunda. Após a confecção das restaurações em resina composta e 24h de armazenamento em estufa a 37°C, os ensaios de DUH foram realizados no ultramicrodurômetro DUH-211S (Shimadzu) com carga de 1mN/mseg. Os testes de MC foram realizados na máquina de ensaios universais Instron 5942(Instron Co) com velocidade de 1mm/min seguido da análise do padrão de fratura em microscópio digital. A análise estatística foi realizada por ANOVA (p<0,01%), Tukey e correlação de Pearson (p<0,05%). O sistema SB Universal (M=31,82±4,72) evidenciou os maiores valores de resistência de união e o Clearfil SE (M=26,75±3,73) os menores. O Single Bond 2 (M=28,83±4,07) e Scotchbond MP (M=28,53±4,61) não apresentaram diferenças entre si e obtiveram valores intermediários, não se diferenciando do maior e nem do menor valor. A resistência de união na dentina rasa (M=30,45±4,40) foi maior que em dentina profunda (M=27,52±4,01). Os sistemas SB Universal (M=22,57±2,42) e Scotchbond MP (M=22,13±2,89) não apresentaram diferença entre si e evidenciaram valores de dureza na camada de adesivo maiores que o Clearfil SE (M= 19,11±1,23). O sistema Single Bond 2 (M=20,11±1,49) apresentou valores intermediários de dureza e não foi diferente do maior e do menor valor. A camada híbrida em dentina rasa (M=38,23±3,08) apresentou maior dureza que a camada híbrida em dentina profunda (M=33,09±1,85). Pode-se concluir que tanto o sistema adesivo utilizado quanto a profundidade dentinária influenciaram nos resultados de resistência adesiva. A dureza da camada de adesivo varia conforme o sistema utilizado sendo que os adesivos SB Universal e o Scotchbond MP apresentaram os maiores valores de dureza. A dureza da camada híbrida foi influenciada pela profundidade dentinária do substrato. Foi observada uma correlação direta entre a dureza da camada de adesivo e a resistência adesiva. / This study evaluated in vitro the hardness of the adhesive layer and the hybrid layer interface between composite and human dentin using nanohardness test (DUH). Was evaluated the bond strength by microshear test (MC) in order to observe the relationship of this resistance with the hardness property. The variation factors consist of four adhesive systems (Adper Scotchbond Multi-Purpose, Adper Single Bond 2, Clearfil SE Bond and Single Bond Universal) and two dentin depths (superficial and deep dentin). The experimental units consisted of 144 dental fragments obtained from molars vestibular area, which were divided into 16 groups, 8 groups with n = 6 for DUH test and 8 groups with n = 12 for the MC test, so the four adhesive systems were applied on dentin fragments of superficial and deep dentin. After the construction of the composite resin restorations and 24h storage at 37 °C, DUH analysis were performed using a nanoindentation device DUH-211S (Shimadzu) with load of 1mN/mseg. The MC tests were performed in a universal testing machine Instron 5942 (Instron Co) with speed 1mm/min followed by analysis of the failure site in digital microscope. Statistical analysis was performed by ANOVA (p <0.01%), Tukey, and Pearson correlation (p <0.05%). The system SB Universal (M = 31.82 ± 4.72) showed higher values of bond strength and Clearfil SE (M = 26.75 ± 3.73) lower. The Single Bond 2 (M = 28.83 ± 4.07) and Scotchbond MP (M = 28.53 ± 4.61) did not differ among themselves and had intermediate values, not differentiating the largest and the smallest value. The bond strength of superficial dentin (M = 30.45 ± 4.40) was higher than in deep dentin (M = 27.52 ± 4.01.) Universal Systems SB (M = 22.57 ± 2.42) and Scotchbond MP (M = 22.13 ± 2.89) did not differ among themselves and showed hardness values in the adhesive layer higher than Clearfil SE (M = 19.11 ± 1.23.) The system Single Bond 2 (M = 20.11 ± 1.49) showed intermediate values of hardness and was not different from the largest and smallest value. The hybrid layer in superficial dentin (M = 38.23 ± 3.08) was harder than the hybrid layer in depth dentin (M = 33.09 ± 1.85.) It can be concluded that both the adhesive system used as the dentin depth influenced the bond strength. The hardness of the adhesive layer varies depending on the system used and the SB Universal adhesive and Scotchbond MP showed higher hardness values. The hardness of the hybrid layer was influenced by the depth of the dentin substrate. We observed a direct correlation between the hardness of the adhesive layer and the bond strength.

Page generated in 0.0239 seconds