• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 334
  • 16
  • 9
  • 9
  • 9
  • 9
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 359
  • 248
  • 94
  • 80
  • 69
  • 56
  • 54
  • 54
  • 51
  • 51
  • 50
  • 44
  • 43
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Efeitos do Laser de Dióxido de Carbono (CO2) no esmalte dentário / Effects of carbon dioxide (CO2) laser on dental enamel

Vieira, Karlla Almeida 16 August 2018 (has links)
Orientador: Marinês Nobre dos Santos Uchôa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T01:03:34Z (GMT). No. of bitstreams: 1 Vieira_KarllaAlmeida_D.pdf: 15064660 bytes, checksum: e1414c7c074b5c185aa76909178b8f10 (MD5) Previous issue date: 2010 / Resumo: A irradiação do esmalte dentário com o laser de Dióxido de Carbono (CO2) modifica a superfície deste substrato e traz benefícios no que diz respeito a um aumento na resistência aos ácidos quando ocorre um desafio cariogênico. Sendo assim, esta tese constituída por 2 artigos, teve os seguintes objetivos: (1) revisar sistematicamente o efeito da irradiação do esmalte (mudanças morfológicas e de composição) pelo laser de CO2 com comprimento de onda 10,6 µm e sua resistência a desmineralização; (2) investigar, in vitro, o efeito de quatro aplicações sobrepostas do laser de CO2 (10,6 µm) na redução da desmineralização do esmalte dentário humano. Para o estudo 1, foi realizada uma busca na literatura científica, em base de dados universais no que concerne ao tema. No estudo 2, uma a quatro aplicações sobrepostas do laser de CO2 (10,6 µm) com 10 J/cm2 foram realizadas no esmalte dentário e os efeitos dessas aplicações foram avaliados pelas análises de Espectroscopia FT-Raman, Espectrometria de Fluorescência de Raio-X de Energia Dispersiva, Microdureza e Microscopia Eletrônica de Varredura. No estudo 2, a perda mineral do esmalte foi determinada pelo teste de microdureza. Os resultados foram analisados estatisticamente pelos testes ANOVA e Tukey (p<0,05). A análise da literatura apresentada no artigo 1 mostrou que existe uma moderada evidência entre as modificações estruturais e químicas no esmalte, produzidas pela irradiação com o laser de CO2 (10,6 µm), e sua resistência à dissolução ácida quando exposto a um alto desafio cariogênico. O estudo 2 mostrou que uma aplicação do laser de CO2 (10,6 µm) foi suficiente para produzir modificações na superfície do esmalte e que aplicações promoveram um aumento à resistência do esmalte à desmineralização. Sendo assim, a irradiação do esmalte com o laser de CO2 (10,6 µm) modifica a superfície do esmalte tornando este substrato mais resistente à desmineralização frente a um desafio cariogênico. / Abstract: The irradiation of dental enamel with Carbon Dioxide (CO2) laser modifies the surface of this substrate and increases its acid-resistance under a cariogenic challenge. Thus, this thesis comprises 2 manuscripts with the following purposes: (1) to review the existing literature about the effect of a CO2 laser (10.6 µm) irradiation on enamel (structural and compositional changes) and its resistance to demineralization; (2) to investigate, in vitro, the effect of four CO2 laser (10.6 µm) applications on the reduction of human dental enamel demineralization. In study 1, the scientific literature related to the theme was searched using universal databases. In study 2, one to four CO2 laser (10.6 µm) applications (10 J/cm2) were performed on dental enamel and the results of the effects of these applications were evaluated by FT-Raman spectroscopy, Energy-dispersive X-ray fluorescence spectroscopy, Microhardness analysis and Scanning electron microscopy. In study 2, the enamel mineral loss was determined by microhardness test. Results were analyzed by ANOVA and Tukey's test (p<0.05). The literature review showed moderate evidence between the structural and chemical modifications, occurring on the enamel surface induced by with CO2 laser (10.6 µm) irradiation, and its reduction to demineralization when exposed to a high cariogenic challenge. The study 2, showed that one CO2 laser (10.6 µm) application was able to modify the enamel surface and that three irradiations did enhance the enamel resistance to demineralization. Therefore, irradiation of enamel with CO2 laser (10.6 µm) was able to promote modifications on its surface, which leads this a substrate more resistant to the demineralization process when a cariogenic challenge occurs. / Doutorado / Odontopediatria / Doutor em Odontologia
262

Dureza da camada de adesivo e da camada híbrida e a sua relação com a resistência de união à dentina / Hardness of the adhesive layer and the hybrid layer and its relationship to bond strength to dentin

Paula Mendes Acatauassú Nunes 02 September 2013 (has links)
Este estudo avaliou in vitro a dureza da camada de adesivo e da camada híbrida de uma interface entre resina composta e dentina humana por meio de ensaios de nanodureza (DUH). Foi avaliada a resistência de união por meio de testes de microcisalhamento (MC) com o objetivo de observar a relação desta resistência com a propriedade da dureza. Os fatores de variação compreendem quatro sistemas adesivos (Adper Scotchbond Multiuso, Adper Single Bond 2, Clearfil SE Bond e Single Bond Universal) e duas profundidades dentinárias (dentina rasa e dentina profunda). As unidades experimentais foram compostas por 144 fragmentos dentais obtidos da face vestibular de molares humanos, os quais foram distribuídos em 16 grupos, 8 grupos com n=6 para os ensaios de DUH e 8 grupos com n=12 para os ensaios de MC de forma que os quatro sistemas adesivos foram aplicados sobre fragmentos de dentina rasa e de dentina profunda. Após a confecção das restaurações em resina composta e 24h de armazenamento em estufa a 37°C, os ensaios de DUH foram realizados no ultramicrodurômetro DUH-211S (Shimadzu) com carga de 1mN/mseg. Os testes de MC foram realizados na máquina de ensaios universais Instron 5942(Instron Co) com velocidade de 1mm/min seguido da análise do padrão de fratura em microscópio digital. A análise estatística foi realizada por ANOVA (p<0,01%), Tukey e correlação de Pearson (p<0,05%). O sistema SB Universal (M=31,82±4,72) evidenciou os maiores valores de resistência de união e o Clearfil SE (M=26,75±3,73) os menores. O Single Bond 2 (M=28,83±4,07) e Scotchbond MP (M=28,53±4,61) não apresentaram diferenças entre si e obtiveram valores intermediários, não se diferenciando do maior e nem do menor valor. A resistência de união na dentina rasa (M=30,45±4,40) foi maior que em dentina profunda (M=27,52±4,01). Os sistemas SB Universal (M=22,57±2,42) e Scotchbond MP (M=22,13±2,89) não apresentaram diferença entre si e evidenciaram valores de dureza na camada de adesivo maiores que o Clearfil SE (M= 19,11±1,23). O sistema Single Bond 2 (M=20,11±1,49) apresentou valores intermediários de dureza e não foi diferente do maior e do menor valor. A camada híbrida em dentina rasa (M=38,23±3,08) apresentou maior dureza que a camada híbrida em dentina profunda (M=33,09±1,85). Pode-se concluir que tanto o sistema adesivo utilizado quanto a profundidade dentinária influenciaram nos resultados de resistência adesiva. A dureza da camada de adesivo varia conforme o sistema utilizado sendo que os adesivos SB Universal e o Scotchbond MP apresentaram os maiores valores de dureza. A dureza da camada híbrida foi influenciada pela profundidade dentinária do substrato. Foi observada uma correlação direta entre a dureza da camada de adesivo e a resistência adesiva. / This study evaluated in vitro the hardness of the adhesive layer and the hybrid layer interface between composite and human dentin using nanohardness test (DUH). Was evaluated the bond strength by microshear test (MC) in order to observe the relationship of this resistance with the hardness property. The variation factors consist of four adhesive systems (Adper Scotchbond Multi-Purpose, Adper Single Bond 2, Clearfil SE Bond and Single Bond Universal) and two dentin depths (superficial and deep dentin). The experimental units consisted of 144 dental fragments obtained from molars vestibular area, which were divided into 16 groups, 8 groups with n = 6 for DUH test and 8 groups with n = 12 for the MC test, so the four adhesive systems were applied on dentin fragments of superficial and deep dentin. After the construction of the composite resin restorations and 24h storage at 37 °C, DUH analysis were performed using a nanoindentation device DUH-211S (Shimadzu) with load of 1mN/mseg. The MC tests were performed in a universal testing machine Instron 5942 (Instron Co) with speed 1mm/min followed by analysis of the failure site in digital microscope. Statistical analysis was performed by ANOVA (p <0.01%), Tukey, and Pearson correlation (p <0.05%). The system SB Universal (M = 31.82 ± 4.72) showed higher values of bond strength and Clearfil SE (M = 26.75 ± 3.73) lower. The Single Bond 2 (M = 28.83 ± 4.07) and Scotchbond MP (M = 28.53 ± 4.61) did not differ among themselves and had intermediate values, not differentiating the largest and the smallest value. The bond strength of superficial dentin (M = 30.45 ± 4.40) was higher than in deep dentin (M = 27.52 ± 4.01.) Universal Systems SB (M = 22.57 ± 2.42) and Scotchbond MP (M = 22.13 ± 2.89) did not differ among themselves and showed hardness values in the adhesive layer higher than Clearfil SE (M = 19.11 ± 1.23.) The system Single Bond 2 (M = 20.11 ± 1.49) showed intermediate values of hardness and was not different from the largest and smallest value. The hybrid layer in superficial dentin (M = 38.23 ± 3.08) was harder than the hybrid layer in depth dentin (M = 33.09 ± 1.85.) It can be concluded that both the adhesive system used as the dentin depth influenced the bond strength. The hardness of the adhesive layer varies depending on the system used and the SB Universal adhesive and Scotchbond MP showed higher hardness values. The hardness of the hybrid layer was influenced by the depth of the dentin substrate. We observed a direct correlation between the hardness of the adhesive layer and the bond strength.
263

Estudo comparativo in vitro das estruturas orgânicas e inorgânicas da dentina saudável e esclerosada humana e bovina: nanodureza, concentração de Ca e P e análise morfológica / In vitro comparative study of organic and inorganic components analysis of health and sclerotic human and bovine dentin: nanohardness, Ca and P concentration and morphological analysis

Gisela Muassab Castanho 03 December 2010 (has links)
A dentina esclerosada é um substrato comumente encontrado em pacientes idosos. No entanto, existem poucos estudos comparativos entre dentina humana e bovina esclerosadas. O objetivo deste estudo foi comparar os componentes inorgânicos e orgânicos da dentina saudável e esclerosada humana e bovina, através de cinco parâmetros: nanodureza, módulo de elasticidade, análise quantitativa da concentração de Cálcio (Ca) e Fósforo (P), densidade tubular e morfologia do colágeno. Trinta dentes humanos e 30 bovinos foram distribuídos em 4 grupos experimentais (n=15 por grupo): dentina humana saudável (DHS), esclerosada humana (DEH), bovina saudável (DBS), e bovina esclerosada (DBE). Os dentes saudáveis foram preparados na mesma altura e inclinação dos dentes esclerosados expondo níveis similares da dentina e obtendo fragmentos com 2mm de espessura. Foram realizadas 3 medições por espécime em 3 áreas pré determinadas de dentina intertubular com a utilização do Nanoindentador (carga de 500N por 5 s). Cinco espécimes de cada grupo foram preparados para Microscopia Eletrônica de Varredura (MEV). Com o auxílio da Energia Dispersiva por Raios-X EDX foram obtidos os valores (em percentagem) das concentrações de Ca e P e calculada a relação Ca:P. A contagem dos túbulos por área foi realizada em todas as eletromicrografias. Após descalcificação e preparo, o restante dos espécimes foi analisado em Microscopia Eletrônica de Transmissão (MET). DBS obteve maiores valores de nanodureza comparada à DBE e DHS. DHE sem diferenças com DHS e DBE (p=0,0008). DBS exibiu maiores valores de módulo de elasticidade somente comparada à DHS (p=0,000). A análise estatística não demonstrou diferenças estatisticamente significantes (p=0,71) entre as concentrações de Ca e P. Quanto à densidade tubular (número de túbulos/mm²), os grupos saudáveis foram maiores que os esclerosados e os humanos maiores que os bovinos. As fibras colágenas da DBS mostraram-se mais compactadas e mais desorganizadas que as demais. Pôde se concluir que apenas as concentrações de Ca e P foram similares e que as dentinas esclerosadas humana e bovina mostraram similaridade. Esta pesquisa teve suporte da Fapesp sob o número 2008/10290-8. / The sclerotic dentin has been commonly found in elderly patients. However, there are scarce reports in the literature comparing on the use of human and bovine sclerotic dentins. The objective of this study was to compare inorganic and organic components of healthy and sclerotic dentins from human and bovine. Five parameters were analyzed: nanohardness, elastic modulus, quantitative analysis of Calcium (Ca) and Phosphorous (P) concentrations, tubular density and ultrastructural morphology. Thirty human teeth plus 30 bovine teeth were distributed in 4 experimental groups (n=15 per group): human healthy dentin (HHD), human sclerotic dentin (HSD), bovine healthy dentin (BHD) and bovine sclerotic dentin (BSD). Healthy teeth were cut in the same level and inclination of the sclerotic superficial dentins. The nanohardness and elastic modulus (GPa) of three pre determined areas of each exposed dentin was measured using a nanoindenter (500N for 5s). Five samples of each group were prepared for scanning electron microscopy (SEM) examination. Energy Dispersive X-ray (EDX) was used for obtaining the Ca/P ratio. The tubular density was obtained by counting the tubules in scanning electron micrographs taken in the same magnification and work distance. Data were statistically analyzed by ANOVA complemented by the Tukeys test (p0.05). The ultrastructure of the dentins was observed in specimens processed for transmission electron microscopy (TEM). BHD exhibited significant higher nanohardness than BSD and HHD. HSD nanohardness was similar to those of HHD and BSD (p=0,0008). BHD exhibited significant higher elastic modulus than HHD (p=0,000). The Ca:P ratios were similar amongst all groups (p=0.71). The tubular densities were higher in the healthy dentins than in the sclerotic for both human and bovine. The human dentins presented higher tubular densities than bovine dentins (p=0.000). The intertubular dentin of BHD showed short collagen fibers distributed in a condensed fashion; whereas the other dentins exhibited well-organized long bundles of collagen fibers. It was concluded that sclerotic dentins of human and bovine share most morphological and structural characteristics. This research was supported by Fapesp grants number 2008/10290-8.
264

Avaliação clínica e laboratorial de resina composta em função da fotoativação com diferentes fontes de luz e densidades de potência / Clinical and laboratorial evaluation of resin composite light-cured with different curing units and power densities

Ana Raquel Benetti 27 July 2007 (has links)
O objetivo deste estudo foi avaliar o desempenho clínico e laboratorial de uma resina composta, considerando diferentes fontes de luz e densidades de potência, mantendo-se padronizada a densidade total de energia. O grau de conversão da resina composta foi determinado através de espectroscopia por transformada de Fourier. O grau de amolecimento em etanol foi obtido pela determinação da dureza Wallace, antes e após o armazenamento da resina composta em etanol a 75%. O desgaste foi mensurado por dois métodos: o teste da ACTA e o teste de escovação simulada. Paralelamente, investigou-se o desempenho clínico de restaurações de resina composta em dentes posteriores, submetidas aos mesmos protocolos de fotoativação. Restaurações de classe I de resina composta foram confeccionadas e fotoativadas por lâmpada de quartzo-tungstênio ou diodo emissor de luz a 300 mW/cm2, durante 40 segundos, ou a 600 mW/cm2, durante 20 segundos. As restaurações foram avaliadas, imediatamente e após 6 e 12 meses, por dois examinadores calibrados, de acordo com os critérios modificados de Ryge. Os dados laboratoriais foram submetidos à análise de variância a dois critérios e teste de comparações múltiplas de Newman-Keuls, ou ao teste t-pareado. Os dados clínicos foram analisados pelos testes Kappa, Fisher e McNemar (\'alfa\' = 0,05). Não foram constatadas diferenças significantes quanto aos diferentes protocolos no grau de conversão, no grau de amolecimento em etanol e no desgaste produzido pelo método da ACTA (p > 0,05). Para o teste de desgaste por escovação simulada, a fotoativação com diodos emissores de luz a 300 mW/cm2, durante 40 segundos, resultou em maior desgaste que os demais protocolos testados (p < 0,05). Adicionalmente, não foram observadas diferenças significantes quanto aos diferentes protocolos de fotoativação no desempenho clínico das restaurações, ao final de um ano de avaliação (p > 0,05) / The aim of this study was to evaluate the clinical and laboratorial performance of a resin composite light-cured with different light-curing units and power densities, at a standard energy density level. Degree of conversion of the resin composite was determined by Fourier transformed infrared spectroscopy. The degree of softening of the resin composite in ethanol was obtained by Wallace hardness measurements before and after storage in a 75% ethanol solution. Wear of the resin composite was acquired by two methods: ACTA wear and toothbrush abrasion. Additionally, the clinical performance of resin composite restorations submitted to the same light-curing protocols was followed up. Class I resin composite restorations were light-cured using either halogen lamp or light emitting diode at 300 mW/cm2 during 40 seconds or 600 mW/cm2 during 20 seconds. Restorations were evaluated immediately and after 6 and 12 months by two calibrated dentists, according to the modified Ryge criteria. The laboratorial data were submitted to two-way analysis of variance and Newman- Keuls multiple comparison test, or t-test. Clinical data were analyzed by Kappa, Fisher and McNemar tests (\'alpha\' = 0.05). No significant differences were observed for the different light-curing protocols in the degree of conversion, degree of softening in ethanol, and wear produced by the ACTA method (p > 0.05). For the toothbrush abrasion test, irradiation with the light emitting diode unit for 40 seconds at 300 mW/cm2 resulted in higher wear than the other light-curing protocols (p < 0.05). No significant differences were detected at the one-year clinical follow-up of the resin composite restorations submitted to the various light-curing protocols investigated in this study (p > 0.05).
265

Avaliação da resitência à flexão, dureza e grau de conversão de compósitos para a técnica indireta em função da cor\" / Evaluation of resistance to bending, hardness, degree of conversion of composites for The technique indirect depending on color

Luciane de Lima Franco 01 December 2005 (has links)
O objetivo do trabalho foi avaliar a resistência à flexão, microdureza e grau de conversão de 9 resinas compostas para uso indireto: Solidex (Sl), Epricord (Ep), Belleglass (Be), Signum (Sg), Sinfony (Sy), Tescera (Te), Cristobal (Cr), Targis (Ta) e Adoro (Ad); e uma resina para uso direto como controle, Esthet X (Et), em função da cor: esmalte (E), dentina (D) e translúcido (T). O teste de resistência à flexão (n=15) obedeceu ao método dos três pontos (Kratos) e, após a obtenção dos valores de carga, os corpos de prova fraturados eram posicionados em fita matriz de poliéster e fixados com resina quimicamente polimerizável (Adaptic) no paralelômetro. Em seguida, os corpos de prova eram levados ao microdurômetro (Shimadzu), para obtenção dos valores de microdureza Knoop (n=15), através da aplicação de uma carga de 50gramas por 30 segundos. Para o grau de conversão (n=3), os corpos eram construídos na mesma matriz usada para resistência à flexão, e posicionados em frente ao feixe de infravermelho do espectrofotômetro Raman (Bruker RFS 100/S - 64 scans) para leitura do grau de conversão. A análise de Variância e teste de Tukey foram usados para tratamento dos dados obtidos. A partir dos resultados, chegou-se às seguintes conclusões: 1. Resistência à flexão: O ranqueamento variou em função da cor e as resinas Cr, Sy, Be e Ta tiveram valores de resistência flexural estatisticamente superiores aos dos outros materiais. Os piores materiais foram o Ep, Sg e Sl. A cor não mostrou diferenças significantes (p=12), mas a interação (p<0,0001) e o material (p<0,0001) mostraram. Dois grupos intermediários entre estes foram encontrados. Um deles com valores muito próximos ao grupo com maiores médias de resistência flexural, os quais se encontram os materiais, Et e Te e, um terceiro grupo foi composto pelo material Ad. 2. Microdureza: As resinas Te > Cr > Be > Et, se destacaram com os maiores valores de dureza, (em ordem decrescente de valores de dureza, e com diferenças significantes entre elas). Os piores valores foram obtidos por Ad e Sy com diferenças significantes entre eles. Ep, Sg, Sl e Ta constituíram um grupo com valores intermediários. Portanto, o material (p<0,0001) e a interação (p<0,0001), obtiveram diferenças significantes. Em relação à cor (p<0,0002), a cor indicada para esmalte apresentou valores estatisticamente inferiores do que dentina e translúcido, e deve ser atribuída aos baixos valores em esmalte, em relação a outras cores do material Te. 3. Grau de conversão: Os maiores valores foram obtidos pelo material Te > Be > e = Cr > ou = Sy = Ad. Os materiais Ep e Ta apresentaram valores de grau de conversão logo abaixo destes materiais, e os piores valores de grau de conversão foram mensurados nos materiais Sg, Et e Sl, com diferenças estatisticamente significantes entre eles. Em relação à cor (p<0,0001), a cor indicada como translúcido apresentou valores estatisticamente superiores aos das duas outras cores. Estes resultados são devido aos altos valores apresentados pelos materiais Sy e Ep. Também tiveram valores significantemente diferentes o material (p<0,001) e a interação (p<0,0001). / Objectives: To characterize nine laboratory-processed composite systems (Adoro [Ad], Belleglass [Be], Cristobal [Cr], Epricord [Ep], Sinfony [Sy], Signum [Sg], Solidex [Si], Targis [Ta] andTescera [Te], ) and one composite for direct placement (Esthet-X [Et]) in terms of particle-size distribution and to compare the flexural strength (FS), Knoop hardness (KH) and degree of conversion (DC) of these composites. Materials and methods: Approximately 5 g of composite paste were dissolved in acetone pro analysi, mixed and centrifuged for 30 min at 3000 rpm. The remaining filler particles were dried (37 °C/12 h) and ultrasonically agitated. A computer-controlled apparatus using laser-diffraction technology was used to determine particle size distribution. Specimens (10 x 2 x 1 mm) were fractured with a 3-point bending test (n=15). KH was measured on fragments obtained after the flexural test (25g/30s). Raman spectra of both unpolymerized and polymerized resins were measured at room temperature in the backscattering geometry using the FT-Raman spectrometer. FS, KH and DC data were analyzed with one-way ANOVA and Tukey\'s post-hoc test (?=0.05). Results: The range of particle sizes was dramatically different for each composite. The composite Et showed the narrowest range of particle size while Sg showed the widest range. The highest DC means were observed for Te, Be and Cr. The lowest means were observed for Sg, Et and Si. Cr, Sy and Ta showed the highest FS values, while Ep, Sg and Si showed the lowest FS values. Te, Cr, Be and Et showed the highest KH means, while Ad and Sy the lowest. Conclusions: The composites Te, Cr and Be showed the best performance in all methods evaluated. On the other hand, the indirect composites Ep, Sg and Si demonstrated the worst performance.
266

"Viscoelasticidade em função dos modos de fotoativação de compósitos" / Viscoelasticity as a function of fotoactivation mode

Milton Lazaro Filho 28 September 2004 (has links)
O escoamento viscoelástico pode contribuir ao alívio da tensão gerada durante a polimerização de compósitos aderidos em cavidades. O objetivo do estudo foi verificar a influência de dois modos de fotoativação contínua com diferentes intensidades (1000 mW/cm 2 e 250 mW/cm 2 ) e mesma densidade de energia final (24 J/cm 2 ) sobre propriedades viscoelásticas de dois compósitos comerciais (Filtek A110 e Herculite XRV) após a cura. Os parâmetros viscoelásticos avaliados foram: E’ (módulo de ar-mazenamento), tand (fator de perda) e as constantes reológicas t (tempo de relaxa-mento) e h (viscosidade).. Espécimes (50 x4 x 2 mm), de cada material em cada condição de fortoativação, (total de 51) foram confeccionados à temperatura ambiente e armazenados por 7 dias a 37 o C e submetidos então, a análise dinâmico-mecânica em aparelho DMA 242 (NETZSCH): varreduras de freqüência (50, 20, 10, 5, 2, 1 e 0,1 Hz) em ensaios isotérmicos (25 O C, 37 O C, 50 O C, 70 O C, 80 O C, 90 O C e Tg) em modo flexural (três pontos). Determinou-se também, a temperatura de transição vítrea (Tg). Os resultados de E’ e tand obtidos entre os 3 e os 7 minutos a cada temperatura permitiram a obtenção do módulo complexo E*. A aplicação do princípio de transposição tempo-temperatura de Williams-Landel-Ferry (TTS), resultou na curva mestra a 37 o C de E*(w). A aplicação de algoritmo de Laplace (RSI Orchestrator – Rheometrics), permitiu a obtenção da curva-mestra na mesma temperatura de E*(t). Através da aplicação do modelo matemático de Maxwell discretizado (n=10), obteve-se o espectro de relaxamento, que permitiu a obtenção de t e h de cada ma-terial em cada condição de fotoativação. Foi determinado também, em espécimes especialmente confeccionados para estas finalidades (n=3), o grau de conversão (GC) (análise de FTIR) e micro-dureza Knoop (KHN). Ambas propriedades foram analisadas antes (temperatura ambiente) e depois de tratamento térmico (aquecimento das amostras por 10 minutos a 110 o C). Os resultados do estudo permitiram concluir que: 1) Compósitos ativados com maior intensidade de luz produzem espécimes com menor t e h; 2) E’ e tand são significantemente afetados pelo aumento da intensidade da luz ativadora, diminuindo para Filtek A110 e aumentando para Hercu-lite XRV; 3) A Tg diminui com o aumento da intensidade para Filtek A110 e permanece inalterada para Herculite XRV; 4) Para Filtek A110, GC e KHN dos espécimes curados à temperatura ambiente não mudou com o aumento da intensidade, en-quanto que para Herculite XRV diminuiu; 5) GC e KHN melhoraram para Filtek A110 com o tratamento térmico adicional; para Herculite XRV, apenas KHN melhorou com o tratamento térmico, mas não o GC. / Viscoelastic flow may contribute to the stress relief generated during composites po-lymerization adhered in cavities. The aim of this study was to verify how two modes of continuous photoactivation with different intensities (1000 mW/cm 2 and 250 mW/cm 2 ) and same density of the final energy (24 J/cm 2 ) affect viscoelastic properties after cure of two commercial composites (Filtek A110 and Herculite XRV). The evaluated viscoelastic parameters were: E’ (storage modulus), tand (loss factor) and rheologic constraints t (relaxation time) and h (viscosity). Specimens (50 x4 x 2 mm), of each material at each photoactivation mode (totaled 51) were built at room tem-perature and have been stored for 7 days at 37 o C to undergo the dynamic-mechanical analysis in DMA 242 (Netzsch) equipment. Frequency sweep was made (50, 20, 10, 5, 2, 1 and 0,1 Hz) in each of the isothermic testing (25 O C, 37 O C, 50 O C, 70 O C, 80 O C, 90 O C and Tg) in flexural test (3 points). It was also determined glass transition temperature (Tg). The results of E’ and tand obtained between 3 and 7 min-utes at each temperature allowed to obtain complex modulus E*. The application of time-temperature switch principle of Williams-Landel-Ferry (TTS) ended up in master-curve of E*(w) at 37 o C. The use of the Laplace algorithm (RSI Orchestrator – Rheometrics) allowed to obtain the master curve (at same temperature) of E*(t). By means of the using of discretized Maxwell’s mathematical model (n=10), relaxation spectrum was obtained, which resulted in t and h of each of the materials in each of the photoactivation conditions. Degree of conversion (DC) (FTIR analysis) and Knoop microhardness (KHN) were also determined in specially made specimens for these purposes (n=3). Both properties were analyzed before (room temperature) and after thermal treatment (heating of the specimens for 10 minutes at 110 o C). The results of the study allowed to conclude that: 1) Composites activated with higher intensity yield lower t and h specimens; 2) E’ and tand are meaningfully affected by the increase of the activating light intensity, decreasing for Filtek A110 and increasing for Herculite XRV; 3) Tg decreases with the intensity increase for Filtek A110 and remains un-changed for Herculite XRV; 4) For Filtek A110, DC and KHN of the cured specimens at room temperature, remained unchanged with the intensity increase, while for Her-culite XRV they decreased; 5) DC and KHN raised for Filtek A110 with additional thermal treatment – for Herculite XRV, only KHN improved with thermal treatment, but there were no changes for DC.
267

Comportamento bimodular em osso cortical e novo método para calcular o módulo de elasticidade (E) em resinas compostas / Bimodular behavior in cortical bone and a novel method for measuring elastic modulus (E) of composite resins

Lucas Vinicius Sansana Pabis 29 January 2015 (has links)
O objetivo principal foi investigar se o osso cortical apresenta comportamento bimodular, ou seja, se os valores de módulo de elasticidade (E) dependem do tipo de carregamento que o método utiliza. Para alcançá-lo foi preciso: (1) \"calibrar\" os diferentes métodos em um material conhecidamente unimodular, para afastar a possibilidade de erros ligados à execução de um método. (2) Depurar os métodos já calibrados para torná-los exequíveis em osso cortical. O que foi feito em espécimes de resina composta, que é um material unimodular e com E parecido com o do osso cortical. Foi investigado se o método de medida interfere no valor do E obtido neste material (pois, pelas informações da literatura, existia uma dúvida consistente). Finalmente, (3) foi avaliado se o método de medida, a região anatômica e o indivíduo interferem nos valores de E em espécimes de osso cortical. Adicionalmente, (4) verificou-se a possibilidade de se encontrar e validar uma correlação entre E e dureza Knoop (KH), para medir o E de resinas compostas indiretamente. Espécimes de latão (n = 5) tiveram o seu E calculado por quatro métodos estáticos diferentes (flexão em três pontos; tração; compressão e método de Marshall), que foram calibrados até que todos medissem o valor esperado; os valores de cada método foram comparados por análise de variância de medidas repetidas (o método foi o fator vinculado e o nível de significância foi de 5%). Espécimes (n = 4) de cinco marcas diferentes de resina composta, também foram submetidos aos quatro métodos, fazendo as adaptações pertinentes (depuração), e tiveram o seu E calculado. Estes valores foram submetidos à análise de variância de medidas repetidas (o método foi o fator vinculado e o nível de significância foi de 5 %). Espécimes (n = 48) obtidos em diferentes regiões (periósteo, endósteo e \"transversal\") de fêmures de quatro bois diferentes tiveram seu E calculado através dos métodos devidamente depurados (flexão em três pontos, tração indireta e compressão). Os valores de E foram submetidos a análises de variâncias (nível de significância de 5 %) para avaliar a influência do método, da região e do indivíduo (bois diferentes) sobre os valores de E. O método experimental de tração não foi utilizado para analisar o comportamento bimodular, porque durantes os ensaios com osso cortical, ele apresentou valores com viés. Por isso, os valores de tração foram calculados de forma indireta (Eti) através de uma equação e dos valores experimentais de flexão em três pontos (Eb) e compressão (Ec). Para validar o uso de valores de Eti, eles foram comparados com os respectivos valores de tração experimental (Et) calculados previamente nos espécimes de resinas compostas por análise de variância de medidas repetidas, e não foram achadas diferenças significantes (p > 0,05). Para encontrar e validar a correlação entre E e KH, os valores médios de E em cada espécime de resina (média do E obtido nos 4 métodos em cada espécime) foram submetidos ao teste de correlação de Pearson (nível de significância de 5%) com os respectivos valores experimentais de dureza Knoop (KH) e foi obtida uma equação de regressão linear. Para validar a equação foi confeccionado um segundo grupo de espécimes de resina (de marcas diferentes das utilizadas anteriormente) que teve seu E calculado pelo ensaio de flexão (Eb) e pela equação de regressão proposta previamente (Er); verificou-se então se a correlação entre estes valores (Eb x Er) era significante (nível de significância de 5 %), e se a nova reta de regressão apresentava coeficiente angular não diferente de 1, e coeficiente constante não diferente de zero (critérios de validação). A análise de variância não apontou diferença significante (p > 0,05) entre os valores de E calculados para o metal pelos 4 métodos, e os valores obtidos não diferiram do E conhecido do latão (ao redor de 100 GPa). As depurações necessárias foram realizadas e com elas os diferentes métodos calcularam o E dos espécimes de resina composta de modo consistente: a análise de variância encontrou diferenças significantes (p < 0,05) entre marcas (cujos E médios cobriram a faixa entre 3 e 20 GPa) e não significantes entre os 4 métodos (p > 0,05). Nos espécimes de osso cortical o valor de E foi significantemente dependente (p < 0,05) do método de obtenção (Eti > Eb > Ec). O E dos espécimes obtidos na região \"transversal\" foi menor que o E dos espécimes obtidos na região do endósteo (p < 0,05); no entanto, não houve diferença significante (p > 0,05) entre o E dos espécimes obtidos nas regiões do endósteo e periósteo e entre o E dos espécimes obtidos nas regiões do periósteo e \"transversal\". Ao considerar somente os valores obtidos no ensaio de compressão (Ec), um dos indivíduos apresentou valores de E maiores que os demais (p < 0,05). As médias de E (dos quatro métodos) em cada espécime de resina apresentaram correlação significante com os respectivos valores de KH (p < 0,05) e a equação de regressão linear: E = 0,1602 KH. Também foi significante (p < 0,05) a correlação dos valores de Eb com os respectivos valores de Er (calculados pela regressão E = 0,1602 KH); além disso, a reta de regressão linear desta nova correlação (Eb = 1,0088Er + 0,0475) apresentou coeficiente angular não diferente de 1 e coeficiente constante não diferente de zero. Pode-se concluir que: (1) Quatro métodos de medir o E apresentaram resultados semelhantes em um material metálico. (2) Estes mesmos métodos foram depurados com sucesso para sua utilização em espécimes de osso cortical ao constatar que também não interferiram no valor do E obtido em espécimes semelhantes aos de osso, confeccionados com resinas compostas. (3) Os valores de E de osso cortical dependem do método de medida, o que demonstra seu comportamento bimodular. A região anatômica e o indivíduo também afetam os valores de E dos espécimes de osso cortical (o indivíduo só foi um fator significante ao considerar somente os valores obtidos no ensaio de compressão). (4) Foi encontrada e validada uma correlação entre E e KH em resinas compostas, que permite calcular o E deste material através da regressão E = 0,1602 KH. / The main objective was to investigate whether the cortical bone has a bimodular behavior, that is, if the values of elastic modulus (E) depend on the load type used by the method. To achieve this, it was necessary: (1) \"calibrate\" the different methods in a material with well-known unimodular behavior, for excluding the possibility of systematic errors in the execution of the methods. (2) Depurate the calibrated methods to make them executable in cortical bone. This was made on specimens of composite resin, which is a unimodular material and has an E similar to that of cortical bone. It was also investigated if the method of measuring the E influences the obtained value in this material (because there was a consistent doubt in the literature). Finally (3), we assessed whether the E values in cortical bone are influenced by the measurement method, by the anatomical region and by the individual. Additionally, (4) it was verified if it would be possible suggesting and validating a correlation between E and Knoop hardness (KH), to indirectly measure the E of composite resins. Brass specimens (n = 5) had their E calculated by four different static methods (three point bending, tensile, compression and Marshall\'s method), which were calibrated until all the methods were capable of measuring the expected value; the E values of each method were compared by analysis of variance of repeated measures (the method was the linked factor and the significance level was 5%). Specimens (n = 4) of five different composite resins were also subjected to the four methods, making the relevant adjustments (depuration), and had their E calculated. These values were subjected to analysis of variance of repeated measures (the method was the linked factor and the significance level was 5%); Specimens (n = 48) obtained in different regions (periosteum, endosteum and \"transverse\") of bovine femurs from four different individual had their E calculated using the depurated methods (three point bending, indirect tensile and compression). The E values were subjected to analyzes of variance (significance level of 5%) to evaluate the influence of the method, of the region and of the individual (different cattle) in the E values. The experimental tensile method was not used to analyze the bimodular behavior because during tests on cortical bone, this method showed values with bias. Therefore, the tensile values were indirectly calculated (Eti) by a formula and by the experimental values of E calculated by three point bending (Eb) and compression (Ec). To validate the use of Eti values, they were compared with the corresponding tensile experimental values (Et) previously measured in the composite resins specimens by analysis of variance (repeated measures), and no significant difference was found (p > 0.05). For suggesting and validating the correlation between E and KH, the average values of E of each composite specimen (mean of E obtained considering the values of the four methods in each specimen) were submitted to the Pearson\'s correlation test (significance level of 5 %) with the corresponding experimental KH values and it was obtained the linear regression equation. To validate this equation, it was made a second group of composite resins specimens (with different brands of the previously used) in which the E was calculated by three point bending test (Eb) and by regression equation previously proposed (Er); then it was checked whether the correlation between these values (Eb x Er) was significant (significance level of 5 %), and if the new regression line showed angular coefficient no different from one, and constant coefficient no different from zero (validation criteria). The analysis of variance showed no significant difference (p > 0.05) among the E values calculated for the metal specimens by the four methods; the obtained values did not differ from the known E of the brass (about 100 GPa). The necessary adjustments (depuration) were made and then the different methods calculated the E of the composite resin specimens consistently: the analysis of variance found significant difference (p < 0.05) between composite brands (whose E mean covered the range between 3 and 20 GPa) and no significant difference among the four methods (p> 0.05). In the specimens of cortical bone, the E values were significantly dependent (p < 0.05) of the obtainment method (Eti > Eb> Ec). The E values of the \"transversal\" specimens were lower than the endosteum specimens (p < 0.05); but there was no significant difference (p > 0.05) between the E of endosteum specimens and periosteum specimens and between the E of periosteum specimens and \"transversal\" specimens. When considering just E values of the compression method, one cattle showed higher E values than the others (p < 0.05). The mean of the four methods for each specimen composite resin exhibited a significant correlation with the respective KH values (p < 0.05) and the linear regression equation: E = 0.1602 KH. It was also significant (p < 0.05) the correlation between Eb and the respective Er values (calculated by the regression E = 0.1602 KH); furthermore, the linear regression of this new correlation (Eb = 1.0088Er + 0.0475) presented angular coefficient no different from 1, and constant coefficient no different from zero. It can be concluded that: (1) Four methods of E measuring showed similar results in a metallic material. (2) The same methods were successfully depurated for their execution in cortical bone specimens, since the measurement method did not affect the obtained E value in resin composites (that is a material with E value similar to cortical bone); (3) The E values of cortical bone depend on the measurement method, which demonstrates its bimodular behavior. The anatomical region and the individual also affect the E values of the cortical bone specimens (the individual was a significant factor only when considering just the E values obtained in the compression test). A correlation between E and KH that allows the E estimation by the regression E = 0.1602 KH was suggested and validated in composite resins.
268

Caracterização térmica, grau de conversão, resistência à flexão e dureza de compósitos comerciais tratados termicamente / Thermal characterization, degree of conversion, flexural strength and Knoop hardness of heat treated commercial composites

Caroline Lumi Miyazaki 03 August 2010 (has links)
Visando otimizar as propriedades químicas e mecânicas de compósitos de uso direto aplicados na forma indireta, associados a tratamentos térmicos experimentais (TT), torna-se necessária uma caracterização térmica que permita a determinação de uma temperatura de TT segura (abaixo da temperatura de início de perda de massa). Assim, a primeira etapa deste estudo consistiu em caracterizar termicamente dez compósitos comerciais (Z100, Filtek Z250, Z350 e Supreme XT- 3M ESPE, Esthet-X e TPH Spectrum Dentsply, Charisma Heraeus Kulzer, Tetric Ceram Ivoclar Vivadent, Herculite XRV e Point 4 - Kerr), fotoativados pelo método contínuo (C) e pulse-delay (PD) (20 J.cm-2), por termogravimetria (TG) (n=1) e calorimetria exploratória diferencial (DSC) (n=3). Foram escolhidas duas temperaturas de TT: 100 e 170°C, aplicadas por 10 min, 24h após a fotoativação. A partir disto, avaliaram-se: 1) o grau de conversão (GC), por espectroscopia FT-Raman (n=3); 2) a resistência à flexão em três pontos (RF) (n=10); e 3) a dureza Knoop (KHN) para as faces topo e base (n=3) de quatro destes compósitos (Filtek Z250 e Supreme XT, Esthet-X e Point 4), após diferentes condições: imediatamente, 1h, 6h e 24h após a fotoativação e 24h após fotoativação seguida de TT a 100 ou 170°C. Os dados obtidos foram submetidos à análise de variância e ao teste de Tukey (nível de significância de 5%). Quanto ao GC (%), houve significância estatística para o fator material (p=0,000): Point 4 (68,42) > Z250 (63,05) = Esthet-X (61,69) > Supreme (54,27); condição (p=0,000): TT170 (73,20) = TT100 (73,58) > 24h (62,60) = 6h (60,18) > 1h (55,10) = imediato (53,66); e ativação (p=0,006): C (62,97) > PD (60,75). Também foram significantes as interações material × condição (p=0,007) e material × condição × ativação (p=0,013). Para a RF (MPa), foram encontradas significâncias estatísticas para os fatores material (p=0,000): Z250 (165,48) > Supreme (153,96) > Point 4 (131,30) = Esthet-X (128,06); e condição (p=0,000): TT170 (194,56) > TT100 (182,91) > 24h (150,88) > 6h (131,79) > 1h (111,77) > imediato (96,30); assim como para as interações: ativação × condição (p=0,000), material × condição (p=0,000) e material × ativação × condição (p=0,000). Para a dureza, foram encontradas significâncias estatísticas para os fatores: materialativação (p=0,000): Supreme C (82,46) > Supreme PD (80,29) = Z250 C (77,46) > Z250 PD (74,30) > Esthet-X C (69,17) > Esthet-X PD (65,67) > Point 4 C (57,21) = Point 4 PD (56,71); condição (p=0,000): TT170 (81,35) > TT100 (73,72) > 24h (70,36) > 6h (67,92) > 1h (64,99) > imediato (64,12) e face (p=0,000): topo (71,40) > base (69,40); assim como para as interações: material-ativação × face (p=0,011), material-ativação × condição (p=0,000) e face × condição (p=0,000). A partir dos resultados obtidos, pôde-se concluir que os TTs experimentais propostos foram capazes de aumentar as propriedades estudadas, sendo, de maneira geral, os resultados obtidos com 170°C melhores do que os com 100°C, e ambos melhores do que as demais condições. / Aiming to optimize chemical and mechanical properties of direct composites applied in an indirect way, with an association to experimental heat treatments (TT), it is necessary a thermal characterization, in a way to determine a safe temperature for the TT (below the significant mass loss temperature). Thus, the first step of this study was to perform the thermal characterization of ten commercial composites (Z100, Filtek Z250, Z350 and Supreme XT 3M-ESPE, Esthet-X and TPH Spectrum Dentsply, Charisma Heraeus Kulzer, Tetric Ceram Ivoclar Vivadent, Herculite XRV and Point 4 - Kerr) photoactivated by continuous (C) and pulse-delay (PD) methods (20 J.cm-2), by thermogravimetry (TG) (n=1) and differential scanning calorimetry (DSC) (n=3). After that, two temperatures were chosen for the TT: 100 and 170°C, which were applied for 10 min, 24h after photoactivation. Thus, some properties were evaluated for four composites (Filtek Z250 and Supreme XT, Esthet- X and Point 4): 1) degree of conversion (GC) by FT-Raman spectroscopy (n=3); 2) three-point bending test (RF) (n=10); and 3) Knoop hardness (KHN) for top and bottom surfaces (n=3). The conditions were: immediately, 1h, 6h and 24h after photoactivation and 24h after photoactivation followed by TT at 100 or 170°C. Data were analyzed by ANOVA and Tukeys test (level of significance of 5%). In relation to GC (%), there were statistical significance for the factors material (p=0.000): Point 4 (68.42) > Z250 (63.05) = Esthet-X (61.69) > Supreme (54.27); condition (p=0.000): TT170 (73.20) = TT100 (73.58) > 24h (62.60) = 6h (60.18) > 1h (55.10) = immediately (53.66); and activation (p=0.006): C (62.97) > PD (60.75); and for the interactions: material × condition (p=0.007) and material × condition × activation (p=0.013). For RF (MPa), statistical significance were found for the factors material (p=0.000): Z250 (165.48) > Supreme (153.96) > Point 4 (131.30) = Esthet-X (128.06); and condition (p=0.000): TT170 (194.56) > TT100 (182.91) > 24h (150.88) > 6h (131.79) > 1h (111.77) > immediately (96.30); and also for the interactions: activation × condition (p=0.000), material × condition (p=0.000) and material × activation × condition (p=0.000). For KHN, statistical significance were found for the factors material-activation (p=0.000): Supreme C (82.46) > Supreme PD (80.29) = Z250 C (77.46) > Z250 PD (74.30) > Esthet-X C (69.17) > Esthet-X PD (65.67) > Point 4 C (57.21) = Point 4 PD (56.71); condition (p=0.000): TT170 (81.35) > TT100 (73.72) > 24h (70.36) > 6h (67.92) > 1h (64.99) > immediately (64.12), and face (p=0.000): top (71.40) > bottom (69.40); as for the interactions: material-activation × face (p=0.011), material-activation × condition (p=0.000) and face × condition (p=0.000). By the results, it could be concluded that both proposed experimental TTs were capable of increasing the studied properties, with, in a general way, 170°C generating better mechanical properties than 100°C, and both better than the other conditions.
269

Efeito de materiais contendo compostos bioativos na remineralização de lesões de erosão no esmalte bovino: estudo in vitro / Effect of materials with bioactive compounds on remineralization of bovine enamel with erosion lesions: in vitro study

Simone Soares Pedrosa 25 October 2013 (has links)
A erosão dentária ocasiona a perda da estrutura dental através da dissolução da sua porção mineralizada por ácidos de origem não bacteriana. Assim, o objetivo deste estudo é avaliar a capacidade de materiais contendo compostos bioativos de remineralizar o esmalte bovino submetido a desafio erosivo e se o método de quantificação da fluorescência induzida por luz (QLF) tem correlação com os resultados do teste de microdureza Knoop. 120 fragmentos de esmalte bovino foram distribuídos entre os grupos experimentais, sendo n=5 para o teste de microdureza (3 x 3 x 2 mm) e n=10 para o método do QLFTM (5 x 5 x 3 mm). Os corpos-de-prova foram analisados em três momentos diferentes (inicial, após 2 dias de protocolo de erosão e após 6 dias de tratamento remineralizador). As amostras foram submetidas a 2 dias de protocolo de erosão, através de imersão em ácido cítrico a 0,3% pH 3,2, por 2 minutos e manutenção das mesmas em saliva artificial (pH 7,0) durante 24 horas. Na sequência, foram realizados os tratamentos remineralizadores por 6 dias consecutivos: 1 gota de saliva foi depositada sobre as amostras e após 1 hora foram imersas por 2 minutos em suspensão aquosa preparada com os seguintes materiais: G1-Pro-Argin+NaMFP, bicarbonato de arginina + carbonato de cálcio + monofluorfosfato de sódio (Colgate® Sensitive Pró-Alívio); G2-Recaldent+NaF, fosfopeptídeo de caseína com fosfato de cálcio amorfo + fluoreto de sódio (MI Paste Plus); G3-ACP+NaF, fosfato de cálcio amorfo + fluoreto de sódio + nitrato de potássio (Relief ACP); G4-CaGP+KF, glicerofosfato de cálcio + fluoreto de potássio (Flúor Protector Gel); G5-NovaMin®+NaF, fosfosilicato de cálcio e sódio + fluoreto de sódio (Nupro® Sensodyne®); G6-NovaMin®+NaMFP, fosfosilicato de cálcio e sódio + monofluorfosfato de sódio (Sensodyne® Repair&Protect); G7-NaF, fluoreto de sódio + nitrato de potássio (Sensodyne® Cool Gel) e G8-saliva artificial (controle negativo). Após 2 horas de imersão em saliva foi repetido o protocolo de erosão. Foram realizadas análises estatísticas para o teste de microdureza e QLF (=0,05). A ANOVA de dois fatores para medidas repetidas mostrou diferenças estatisticamente significativas apenas para os momentos da análise e para a interação dos fatores tratamentos x momentos da análise. O teste de Tukey mostrou diferenças significativas na comparação entre todos os momentos da análise e na interação momentos da análise x tratamentos: valores iniciais x após erosão e após tratamento e entre os valores após erosão x após tratamento (NovaMin®+NaF, NovaMin®+NaMFP, NaF e saliva). O teste de Tukey na comparação dos tratamentos no momento final da análise mostrou diferenças significativas na análise da microdureza para o Recaldent+NaF x NovaMin®+NaF, NovaMin®+NaMFP e NaF; mas no QLF, as diferenças ocorreram entre o Pro-Argin+NaMFP x NaF e saliva; Recaldent+NaF x NovaMin®+NaMFP, NaF e saliva e ACP+NaF x NaF. Nenhum dos tratamentos foi capaz de remineralizar totalmente o esmalte dental, mas os materiais Pro-Argin+NaMFP, Recaldent+NaF, ACP+NaF e CaGP+KF foram capazes de estabilizar o processo de erosão do esmalte com resultado superior aos demais tratamentos. O método do QLF mostrou uma correlação positiva significativa com os resultados do teste de microdureza. / Dental erosion leads to loss of the tooth structure by dissolving its mineral portion by acids for non-bacterial origin. The objective of this study is evaluate the ability of materials with bioactive compounds to remineralize bovine enamel subjected to erosive challenge and verify the possible correlation between the datas from the quantitative light-induced fluorescence method (QLF) and the Knoop surface microhardness test. 120 bovine enamel pieces were distributed among experimental groups with n=5 for microhardness testing (3 x 3 x 2 mm) and n=10 for the QLF method (5 x 5 x 3 mm) and were analysed at three different times (initial, after 2 days of erosion protocol and after 6 remineralizing days of treatment).The samples were subjected to two-days erosion protocol, through its immersion into 0,3% citric acid solution pH 3,2 for 2 minutes and maintaining them into artificial saliva for 24 hours (pH 7,0). Following remineralizing treatments were performed for 6 consecutive days: the samples were covered with 1 drop of saliva and after 1 hour were immersed for 2 minutes in the slurry prepared with the following materials: G1-Pro-Argin+NaMFP, arginine bicarbonate + calcium carbonate + sodium monofluorophosphate (Colgate® Sensitive Pro-Alívio); G2-Recaldent+NaF, casein phosphopeptide-amorphous calcium phosphate + sodium fluoride (MI Paste Plus); G3-ACP+NaF, amorphous calcium phosphate + sodium fluoride + potassium nitrate (Relief ACP); G4-CaGP+KF, calcium glycerophosphate + potassium fluoride (Fluor Protector Gel); G5- NovaMin®+NaF, calcium sodium phosphosilicate + sodium fluoride (Nupro® Sensodyne®); G6-NovaMin®+NaMFP, calcium sodium phosphosilicate + sodium monofluorophosphate (Sensodyne® Repair&Protect); G7-NaF, sodium fluoride + potassium nitrate (Sensodyne® Cool Gel) and G8-Artificial saliva (negative control). After 2 hours of soaking in saliva the erosion protocol was repeated. Statistical analyzes were conducted for microhardness and QLF with coincidence of the results (=0,05). A two-factors ANOVA for repeated measures showed statistically significant differences only for the time of analysis and the interaction treatments x time of analysis. The Tukey test showed statistically significant differences when comparing the three times of analysis and the interaction between times of analysis x treatments: baseline values with values after erosion and after treatment and the values after erosion x after treatment (NovaMin®+NaF, NovaMin®+NaMFP, NaF and saliva). The Tukey test when comparing the treatments x final times of analysis showed statistically significant differences in microhardness test for Recaldent+NaF x NovaMin®+NaF, NovaMin®+NaMFP and NaF; in QLF method the differences occurs between Pro-Argin+NaMFP x NaF and saliva; Recaldent+NaF x NovaMin®+NaMFP, NaF and saliva; ACP+NaF x NaF. None of the treatments was able to completely remineralize bovine enamel, but Pro-Argin+NaMFP, Recaldent+NaF, ACP+NaF and CaGP+KF materials were able to stabilize the eroding enamel, thus demonstrating a score higher than others and the QLF method showed a significant and positive correlation with the microhardness test results.
270

Avaliação da microdureza de resina composta polimerizada com fontes de luz halógena e LED, em função da densidade de energia luminosa irradiada / Knoop hardness analisys of a resin composite activated by halogen lamp and LED, varying the luminous density

Rosana Aparecida Pereira 08 July 2009 (has links)
No presente estudo, avaliou-se a microdureza da resina composta Z250 (3M ESPE), quando ativada em diferentes tempos (s), diferentes densidades de potência (mW/cm²), em relação à quantidade de energia irradiada (8, 12 e 16 J/cm²), com a finalidade de estabelecer uma densidade de energia luminosa mínima capaz de polimerizar adequadamente os compósitos. Foi utilizado um aparelho com fonte de luz halógena Degulux-Degussa, com 600 mW/cm² e dois aparelhos de fonte de luz LED, Ultraled XP (Dabi-Atlante) com 150 mW/cm² e LED Ultrablue-IS (DMC) com 300 mW/cm² e 600 mW/cm². Duas matrizes bipartidas de PTFE, de 1 e de 2 mm de espessura e um orifício central de 5 mm de diâmetro, foram usadas para confeccionar 60 corpos-de-prova, 5 em cada grupo. As duas partes da matriz foram contidas em um anel metálico com as mesmas espessuras. O material foi inserido na matriz e fotoativado de acordo com os diferentes tempos e a quantidade de densidade de energia luminosa para cada fonte de luz. Para obter os valores de microdureza Knoop, os espécimes foram levados ao microdurômetro Shimadzu HMV-2, com carga estática de 300 g por 5 segundos, para aferir as superfícies exposta (topo) e oposta (base) à fonte de luz, totalizando 120 medições. Os resultados foram submetidos aos testes ANOVA e Tukey, com nível de significância de 5%. Com os dados obtidos foi possível concluir que, com valores a partir de 16 J/cm² e 12 J/cm² de densidade de energia luminosa, espessuras de 2 mm de resina composta podem ser adequadamente polimerizadas utilizando-se fonte de luz halógena (600 mW/cm²) e LED (a partir de 300 mW/cm²) respectivamente. Contudo, estudos clínicos adicionais ainda são necessários para complementar este estudo / At this study it was evaluated the microhardness of the Z250 (3M ESPE) resin composite, when light cured for different periods of time (s), with different power densities (mW/cm²), related to the irradiated luminous energy density (8 J/cm², 12 J/cm² and 16 J/cm²), in order to establish a minimal energy density capable of adequately polymerize the composites. One halogen light curing unit Degulux- Degussa, with 600 mW/cm² of power density and two light-emitting diodes curing units Ultraled XP (Dabi-Atlante) with 150 mW/cm² and LED Ultrablue-IS (DMC) with 300 mW/cm² and 600 mW/cm² were used. Two bipartite PTFE matrices, with 1 and 2 mm of depth and a central orifice of 5 mm diameter, were used to make 60 specimens, 5 per group. The halves of the matrix were positioned inside a brass ring with both depths to prepare the specimens. The resin composite was inserted and light-activated according to the different periods and energy densities of each lightcuring unit. To evaluate Knoop microhardness, specimens were taken to a microdurometer Shimadzu HMV-2 with a static load of 300 g for 5 seconds, evaluating both exposed to light (surface) and opposite to light (base) exposition surfaces, totalizing 120 measurements. Results were submitted to ANOVA and Tukeys test with 5% significance level. Based on the obtained results, it was concluded that, starting from 16 J/cm² and 12 J/cm² of energy luminous density, 2 mm depth resin composite can be adequately polymerized utilizing halogen (600 mW/cm²) and LED ( starting from 300 mW/cm²) curing-units respectively. However, additional clinical studies are necessary to complement this investigation.

Page generated in 0.0423 seconds