SPHEROID DETECTION IN 2D IMAGES USING CIRCULAR HOUGH TRANSFORMChaudhary, Priyanka 01 January 2010 (has links)
Three-dimensional endothelial cell sprouting assay (3D-ECSA) exhibits differentiation of endothelial cells into sprouting structures inside a 3D matrix of collagen I. It is a screening tool to study endothelial cell behavior and identification of angiogenesis inhibitors. The shape and size of an EC spheroid (aggregation of ~ 750 cells) is important with respect to its growth performance in presence of angiogenic stimulators. Apparently, tubules formed on malformed spheroids lack homogeneity in terms of density and length. This requires segregation of well formed spheroids from malformed ones to obtain better performance metrics. We aim to develop and validate an automated imaging software analysis tool, as a part of a High-content High throughput screening (HC-HTS) assay platform, to exploit 3D-ECSA as a differential HTS assay. We present a solution using Circular Hough Transform to detect a nearly perfect spheroid as per its circular shape in a 2D image. This successfully enables us to differentiate and separate good spheroids from the malformed ones using automated test bench.
|
2 |
Phénomènes locaux instationnaires dans les piles à combustible à membrane (PEMFC) fonctionnant en mode bouché (dead-end) / Local transient phenomena in PEM fuel cell with dead-ended anodeAbbou, Sofyane 02 December 2015 (has links)
Cette thèse concerne les phénomènes locaux qui se produisent dans une pile à combustible à membrane (PEMFC) fonctionnant en mode bouché. Ce mode de fonctionnement consiste à alimenter l’anode en hydrogène sec tout en maintenant sa sortie fermée ce qui favorise l’accumulation d’eau et d’azote (issus du compartiment cathodique) près de la sortie anodique. Certaines régions sont donc convenablement alimentées en gaz tandis que d’autres ne le sont plus. Ces déséquilibres s’accompagnent de hausses localisées de potentiel (à l'anode et à la cathode) qui accélèrent la dégradation du catalyseur et de son support carboné à la cathode. Afin d’étudier ces dégradations à une échelle locale, une cellule segmentée novatrice permettant la mesure simultanée des densités de courant et des potentiels locaux a été développée. Des protocoles de vieillissement accélérés reposant sur un fonctionnement prolongé en mode bouché montrent que les pics de potentiel ont pour conséquence, après quelques heures, une distribution non-uniforme de la surface active (ECSA) à la cathode et des courants le long de la cellule : les dommages sont plus prononcés dans les zones les plus touchées par le déficit en hydrogène. Des études paramétriques et un modèle numérique permettent de comprendre que le déficit en hydrogène résulte principalement de l’accumulation d’eau liquide dans les canaux de l’anode, bien que l'azote joue également un rôle. Par conséquent, la gestion de l’eau impacte fortement les variations de potentiel à la cathode et donc leurs conséquences en termes de dégradation ; basées sur ces constatations, des solutions sont proposées pour améliorer les durée de vie des piles / This work investigates the local transient phenomena occurring in proton exchange membrane fuel cells (PEMFC) operated with a dead-ended anode. The dead-end mode consists in closing the anode outlet, which leads eventually to local hydrogen starvation due to the excessive accumulation of liquid water and nitrogen (because of membrane crossover) in the anode compartment. Such fuel-starvation events may remain undetected but can entail a significant rise of the anode (and thus cathode) potentials and accelerate carbon corrosion and catalyst degradation. To access local information, we developed an innovative segmented linear cell with reference electrodes along the gas channels. By simultaneously monitoring the local potentials and current densities during operation, we assessed the impact of fuel starvation and observed strong local cathode potential excursions close to the anode outlet. Aging protocols based on fuel cell operation with a dead-ended anode (longer than in real use condition) showed non-uniform cathode ElectroChemical Surface Area (ECSA) losses and performance degradation along the cell area: the damage was more severe in the regions suffering the longest from fuel starvation. Parametric studies completed by numerical simulations showed that the fuel starvation is mainly governed by liquid water accumulation in the anode channels, as well as nitrogen crossover through the membrane. As a consequence, water management impacts significantly the cathode potential variations and thus the resulting electrode degradation. Starting from this founding, we propose strategies to improve fuel cell lifetime
|
3 |
Mécanismes de vieillissement de l'Assemblage-Membrane-Électrodes dans une pile à combustible de type PEM par approche expérimentale / Mechanisms of Membrane-Electrode-Assembly aging in PEMFC by experimental approachHuang, Botao 17 July 2012 (has links)
Cette thèse a permis de mettre en évidence les mécanismes de vieillissement de la pile à combustible de type PEM lors de cyclages d'humidité de l'air et suite à la perforation de l'AME (Assemblage Membrane Electrodes). Premièrement, les mécanismes connus de dégradation des divers composants (membrane, catalyseur, support du catalyseur, GDL, plaques bipolaires et joints d'étanchéité) ont été présentés. Ensuite, les outils de diagnostic en-ligne (chronopotentiométrie, spectroscopie d'impédance, gestion de l'eau et analyse chimique de l'eau) et ceux hors-ligne (CV et LSV) ainsi que des analyses post-mortem (RMN, MET, MEB et DRX) ont été décrits. Expérimentalement, le cyclage en humidité de l'air a été effectué en mono-cellule de 25 cm2: le cyclage à forte humidité entraîne une perte significative de la surface électroactive du catalyseur; le cyclage à faible humidité favorise la perméation de l'hydrogène à travers la membrane. Le cyclage à faible humidité réalisé sur une pile de 100 cm2 a montré un mécanisme de dégradation différent de celui de la pile de 25 cm2: la perméation de l'hydrogène reste faible alors que la tension de la pile était de plus en plus fluctuante certainement du fait de la présence de volumes morts et de la rétention d'eau liquide dans la pile. L'effet de la perforation de l'AME a été étudié sur une pile de 100 cm2: la perforation par une punaise de 0,7 mm de diamètre ne génère qu'une légère augmentation de la perméation de l'hydrogène; la perforation par une punaise de 1,2 mm de diamètre entraîne une chute de tension et l'augmentation significative de la résistance de diffusion de l'oxygène due à la perméation importante de l'hydrogène / This thesis highlights the aging mechanisms of PEM Fuel Cell submitted to two main aging conditions: air relative humidity (RH) cycling, and MEA (Membrane Electrode Assembly) pinhole test of operation. First, the aging mechanisms of PEMFC main components (membrane, catalyst, carbon support, GDL, bipolar plates and gaskets), have been reviewed from the literature. Then the on-line diagnostic tools (chronopotentiometry, electrochemical impedance spectroscopy, water management and water analysis), off-line ones (cyclic voltammetry and linear sweep voltammetry) and post-mortem analyses (nuclear magnetic resonance, transmission electron microscopy, scanning electron microscopy and X-ray diffraction) have been described. Experimentally, the high and low air RH cycling runs have been carried out with a 25 cm2 single cell: the high air RH cycling run promoted serious loss of the ElectroChemical Surface Area (ECSA); the low air RH cycling run caused significant increase in hydrogen crossover. The low air RH cycling has been also performed with a 100 cm2 single cell and the aging mechanism was different from that of 25 cm2 cell: the hydrogen crossover remained very low but the fuel cell voltage exhibited strong fluctuations at the end of the run: this was attributed to the presence of dead volumes and liquid water retention within the cell. Finally, MEA pinhole effect has been investigated with a 100 cm2 single cell: the perforation by a 0.7 mm diameter pin promoted slight increase in the hydrogen crossover; the perforation by a 1.2 mm diameter pin caused significant cell voltage losses and serious increase in the cathode diffusion resistance due to significant hydrogen crossover
|
Page generated in 0.0204 seconds