441 |
Influência do clima no desempenho energético de condicionador de ar com tecnologia VRF em condição de carga parcial para hotéisXavier, Ademilson dos Santos 13 October 2016 (has links)
Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2017-02-08T12:58:24Z
No. of bitstreams: 1
Ademilson dos Santos Xavier_.pdf: 9916385 bytes, checksum: 8bcbfe8f2b36b5a58781ce2518c1bb83 (MD5) / Made available in DSpace on 2017-02-08T12:58:24Z (GMT). No. of bitstreams: 1
Ademilson dos Santos Xavier_.pdf: 9916385 bytes, checksum: 8bcbfe8f2b36b5a58781ce2518c1bb83 (MD5)
Previous issue date: 2016-10-13 / Nenhuma / Estudos recentes mostraram que uma grande parte da energia elétrica consumida no Brasil destina-se a edificações do setor Comercial e Público. Observando-se que o sistema de HVAC (Heating, Ventilation, and Air Conditioning) apresenta relevante papel no quadro final do consumo energético em edificações, a determinação de seus requisitos mínimos de eficiência energética torna-se o fator chave para o sucesso de qualquer programa de certificação energética em construções. Esse trabalho tem como objetivo avaliar de que forma as condições climatológicas brasileiras podem influenciar o desempenho de um sistema condicionador de ar com tecnologia VRF (Variable Refrigerant Flow) em Condições de Carga Parcial (Part Load Conditions), para uma edificação comercial. Para isso, foi desenvolvida uma metodologia capaz de identificar as localidades que foram objetos desse estudo. As cidades selecionadas foram: São Paulo (SP), Rio de Janeiro (RJ), Fortaleza (CE) e Brasília (DF). Após esta etapa, a caracterização do edifício modelo de referência (hotel) foi concretizada. Características físicas, valores de carga térmica externa e interna, e o perfil de uso (taxa de ocupação) da edificação, foram tópicos abordados. O software de simulação utilizado foi o EnergyPlus e as suas respectivas curvas e equações de desempenho foram ajustadas com base nos dados de performance dos aparelhos condicionadores de ar que foram selecionados. O fabricante Toshiba foi escolhido. A performance dos equipamentos VRF foi analisada através de resultados como Carga Térmica global, Condição de Carga Plena, Condições de Carga Parcial, PLR (Part Load Ratio), COP (Coefficient of Performance) e ICOP (Coeficiente Integrado de Performance). Os resultados mostraram que apesar da Condição de Carga Plena (Full Load Condition) ser recomendada para dimensionar o sistema de HVAC, quando o objetivo principal for avaliar o desempenho energético desse sistema (HVAC) para um período mais longo de operação essa análise deve ser realizada através das Condições de Carga Parcial (Part Load Conditions). Para as quatro localidades estudadas os valores de desempenho obtidos através das simulações mostram que os equipamentos de ar condicionado VRF utilizados atingiram o seu coeficiente máximo de performance (COPmáx) na condição de 50% de PLR e um ICOP de 6,8, contra um COP de 3,4 na condição nominal e um ICOP de 3,7 de acordo com o Regulamento Técnico da Qualidade do Nível de Eficiência Energética de Edifícios Comerciais, de Serviço e Públicos, RTQ-C. / Currently studies have been shown that a large part of the electricity consumed in Brazil is intended to buildings Commercial and Public Sector. The HVAC system (Heating, Ventilation, and Air Conditioning) shows a significant role in the final frame of the energy consumption in buildings, determining its minimum requirements for energy efficiency becomes the key factor for the success of any program energy certification of buildings. This work aims to analyze how the Brazilian climatic conditions can influence the performance of air conditioner systems with VRF technology (Variable Refrigerant Flow) in the Part-Load Condition for a commercial building. Therefore a methodology was developed to identify the locations that were the subject of this study. The cities selected are: São Paulo (SP), Rio de Janeiro (RJ), Fortaleza (CE) and Brasília (DF). In addition the building characteristics have completed, external and internal thermal load values with their use profile have been analyzed. The software applied was EnergyPlus and their performance curves and equations have been adjusted according with the performance data of air conditioning units selected. The manufacturer Toshiba has been chosen. The VRF equipment performance was analyzed through results as Full-Load Condition, Part-Load Conditions, Part Load Ratio (PLR), COP and COP (Integrated Coefficient of Performance). The main results have showed that despite the Full-Load Condition is recommended to dimension the HVAC system, when the objective is the evaluation of the energy performance for a longer operation period this analysis should be carried out through Part-Load Conditions. For all of the four cities have studied the performance values obtained from the simulations show that the air-conditioning equipment VRF used reached their maximum performance coefficient (COPmáx) at 50% of PLR and ICOP 6.8, against a COP 3.4 in nominal condition and ICOP of 3.72 according to the Quality Technical Regulation of the Energy Efficiency Level Commercial Buildings, and Public Service, RTQ-C.
|
442 |
Avaliação do consumo de energia elétrica para produção de água subterrânea : o caso do abastecimento público da cidade de São Carlos - SP / Evaluation of electric power consumption in groundwater pumping : the case study of the city of São Carlos SPPerroni, Julio Cesar Arantes 23 February 2005 (has links)
Diversos sistemas públicos de abastecimento de água de cidades brasileiras utilizam majoritária ou exclusivamente água subterrânea, captada em poços tubulares profundos sendo que a grande maioria desses poços necessita de equipamentos de bombeamento para efetuar a elevação da água até a superfície com custo operacional elevado relativo às despesas com energia elétrica. No presente trabalho, foi desenvolvida uma metodologia para análise de dados operacionais de poços e respectivos sistemas de bombeamento, incluindo a determinação do rendimento eletromecânico dos equipamentos utilizados. A aplicabilidade da metodologia proposta foi avaliada através de estudo de caso, realizado com 21 poços utilizados no abastecimento público da cidade de São Carlos - SP. Os resultados obtidos indicaram que com a utilização de equipamentos de bombeamento de alto rendimento, será possível reduzir 15% do consumo de energia elétrica, proporcionando uma redução de despesa que poderá cobrir, em 5 anos, mais de 50% dos valores dos investimentos necessários em novos equipamentos. Tendo como diretrizes gerais a otimização do rendimento de poços profundos e a sustentabilidade do uso da água subterrânea a aplicação da metodologia proposta, em sistemas de abastecimento de água, deverá contribuir para a melhoria da qualidade dos serviços e poderá gerar uma significativa economia de recursos / Several public water supply systems of brazilian cities use mainly or exclusively groundwater from water wells, which majority needs pumping equipments to raise the water to the ground surface, and high operating costs due to electricity consumption. In the present work, a methodology to evaluate water wells and pumping equipments operational data was developed, including the calculation of the electromechanical efficiency. The applicability of the proposed methodology is evaluated in a case study of 21 water wells, which are used for public water supply of the city of São Carlos SP. The results have indicated that the use of high level efficiency equipment should reduce 15% of the present electric power consumption and an economy that in a 5 years period could support more than 50% of the necessary investments in new pumping equipment. Taking the optimization of the energy efficiency of water wells and the sustainability of groundwater as general constrains, the application of the proposed methodology may contribute to the improvement of the quality of public water supply facilities and generate a considerable economy
|
443 |
Eficiência em tecnologias de iluminação artificial: o LED e a tecnologia fluorescente / Efficiency in artificial lighting technologies: LED and fluorescent tecnologiesFuruyama, Cristiane Mitiko Sato 29 March 2019 (has links)
Esta pesquisa aborda a depreciação da tecnologia LED comparada à da tecnologia fluorescente nos sistemas de iluminação mais utilizados em ambientes corporativos internos. O resultado da depreciação dos sistemas de iluminação foi obtido por meio da experimentação em uma célula teste, com dois modelos de luminárias (com aletas e com difusor) e três fontes de luz: a tradicional lâmpada fluorescente tubular T5 de 28W, o tubo LED T8 de 18W e LED aplicado sobre a luminária. Os conjuntos foram instalados na célula teste e ficaram ligados por aproximadamente 17.000 horas. As medições foram realizadas a cada 3 meses ao longo de 24 meses (2 anos) com um luxímetro em pontos definidos, de acordo com a norma NBR/ISO 8995:2013. Juntamente com as medições, os sistemas de iluminação foram ensaiados em laboratório acreditado pelo INMETRO em dois momentos. O primeiro ensaio ocorreu com os sistemas de iluminação em zero hora, e o segundo após a depreciação de todos os sistemas de iluminação utilizados na pesquisa. Adicionalmente, foram realizadas simulações computacionais para posterior comparação dos resultados entre simulação e experimentação. Os programas de simulação utilizados foram o Dialux EVO, o Relux e o AGi32. Para verificar as hipóteses da pesquisa, os resultados das medições foram comparados com os valores de fator de manutenção resultantes, conforme norma CIE-97:2005. / This research compares the depreciation of LED technology with fluorescent technology, considering the most commonly used lighting systems in internal corporate environments. The result of the depreciation of these lighting systems was obtained by experimenting inside a testing room, with two models of luminaires - with fins and with diffuser - and three light sources: the traditional T5 tubular fluorescent lamp of 28W, the T8 LED tube of 18W and LED applied over the luminaire. These sets were assembled in the test cell and kept on for approximately 17,000 hours. Measurements were performed every 3 months over 24 months(2 years) using a luximeter. The placement of the testing points were defined according to the NBR/ISO 8995:2013 norm. At the same time, the lighting systems were tested in a laboratory accredited by INMETRO in two distinct moments. The first experiment was done with all lighting systems at zero hour and the second after the depreciation of all lighting systems used in the research. In addition, computational simulations were performed for later comparison of the results between simulation and experimentation. The simulation programs used were Dialux EVO, Relux and AGi32. To verify the hypothesis of this research, the results of the evaluations were compared to the values of the maintenance factor according to the CIE-97:2005 norm.
|
444 |
Solução baseada em programação estocástica para a gestão de redes de distribuição ativas considerando eficiência energética /Quijano Rodezno, Darwin Alexis. January 2018 (has links)
Orientador: Antonio Padilha Feltrin / Resumo: Atualmente, existe uma tendência para aumentar a participação da Geração Distribuída (GD) baseada em Fontes de Energia Renováveis (FER) no suprimento do consumo global de energia elétrica. Esta tendência está sendo impulsionada principalmente por iniciativas governamentais destinadas a aumentar a eficiência energética, aumentar o uso da energia proveniente das FER e reduzir as emissões de gases de efeito estufa. No entanto, à medida que seu nível de penetração aumenta, a GD pode dar origem a um sistema incapaz de fornecer energia de forma confiável e de acordo com os padrões de qualidade. Nesse cenário, a Gestão de Redes Ativas (GRA) surge como uma alternativa para a integração de grandes montantes de GD. A GRA promove a disponibilização de instrumentos comerciais e regulatórios, e o fornecimento das redes de distribuição com tecnologias de automação para procurar serviços ancilares e flexibilidade a partir da GD. A GRA requer o desenvolvimento de ferramentas computacionais para coordenar a implementação de esquemas de controle inteligentes, chamados de esquemas de GRA, a fim de otimizar a utilização e operação das redes. Neste trabalho, são propostos modelos de otimização e técnicas de solução para a GRA considerando a integração de GD solar fotovoltaica e eólica e a eficiência energética. O primeiro modelo é desenvolvido para determinar a capacidade máxima de GD que pode ser alocada em uma rede de distribuição quando se considera o efeito da tensão na eficiência das cargas.... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Nowadays, there is a trend to increase the participation of distributed generation (DG) based on renewable energy sources in supplying the global electricity consumption. This trend is being driven mainly by government initiatives to increase energy efficiency, convert the energy use to renewable sources and reduce greenhouse gas emissions. However, as its penetration level increases, the DG can give rise to a system unable to deliver energy reliably and according to quality standards. In this scenario, active network management (ANM) emerges as an alternative for the integration of large amounts of DG. ANM promotes the availability of commercial and regulatory instruments and the provision of distribution networks with automation technologies for procuring ancillary services and flexibility from the DG. ANM requires the development of computational tools to coordinate the implementation of intelligent control schemes, called ANM schemes, in order to optimize the utilization and operation of distribution networks. In this work, optimization models and solution techniques are proposed for ANM considering the integration of solar and wind-based DG and energy efficiency. The first model is developed to determine the maximum capacity of DG that can be allocated in a distribution network when considering the effect of voltage on load efficiency. In the second model, the procedure of controlling the voltage levels to reduce the load demand is implemented for energy saving and for b... (Complete abstract click electronic access below) / Doutor
|
445 |
REASoN - avaliação de confiabilidade e disponibilidade em redes de computadores sustentáveis. / REASoN - reliability and availability evaluation of sustainability-oriented computer networks.Marcelo Carneiro do Amaral 13 December 2013 (has links)
Redes de computadores orientadas à sustentabilidade ou eficientes energeticamente têm a capacidade de adaptar dinamicamente os modos de consumo de energia dos seus dispositivos de acordo com a demanda do tráfego da rede. Por exemplo, colocar no estado dormente os dispositivos que estão abaixo de um nível de utilização predeterminado, considerado de baixa carga. Neste cenário, existem novos desafios no que diz respeito ao modo como confiabilidade e disponibilidade da rede são avaliadas. O cálculo de confiabilidade e disponibilidade é comumente realizado através das técnicas de cadeia de Markov, ou Conjuntos-Conexos e Conjuntos-Desconexos. Porém, tradicionalmente, estas técnicas são baseadas em valores estáticos e não levam em consideração as mudanças dinâmicas que são inseridas no contexto de redes sustentáveis. Desta forma, este trabalho tem como principais objetivos prover um método capaz de avaliar o impacto na confiabilidade ou disponibilidade da rede, quando alguns dispositivos são colocados e tirados de modos de economia de energia, e apresentar a relação de compromisso entre economia de energia, confiabilidade e disponibilidade da rede. O método proposto, chamado REASoN, é uma composição dos dois métodos supracitados, que foram estendidos de forma a considerar no cálculo a dinamicidade dos ajustes dos níveis de energia. Para fins de avaliação, o trabalho realiza um cálculo numérico empregando o método REASoN, em que foi avaliada a confiabilidade dos dispositivos quando colocados no estado dormente. Os impactos de operações de eficiência energética nas métricas de confiabilidade são expressos como mudanças na quinta casa decimal da confiabilidade da rede como 52 minutos de inatividade de componentes da rede e na quarta casa decimal da disponibilidade com 8h de inatividade. Para uma empresa de transações bancárias, 8h de inatividade pode significar R$ 1 bilhão de perda. O trabalho analisa, também, a implementação do REASoN dentro do contexto de um sistema de gerenciamento de rede orientado a sustentabilidade. Os resultados mostram que, quando o sistema não prioriza disponibilidade e confiabilidade, a economia de energia é de 43%. Já quando a disponibilidade e confiabilidade são priorizadas, a economia é de 27%, um valor representativo. Concluímos que o REASoN é uma ferramenta de grande utilidade para a tomada de decisão em redes de computadores sustentáveis, servindo, como base, para uma análise mais acurada sobre o impacto de mecanismos de economia de energia. / Sustainability-oriented computer networks or energy efficient networks have the ability to dynamically adapt the network device power modes in accordance with the demand of network traffic. For example, by putting to sleep devices that handle traffic below a threshold. In this scenario, new challenges appear in the way that the reliability and availability of the network are evaluated. The calculation of reliability and availability is commonly accomplished through techniques such as Markov chain, or Cut-Set and Tie-Set. However, traditionally these techniques are based on static values and do not take into account the dynamic changes that are in the context of sustainable networks. Thus, this study first aims at providing a method to assess the impact on reliability or availability of the network when some devices are put to sleep. Second, it aims at presenting the trade-off between saving energy and changing the reliability and availability of the network. The proposed method, called REASoN, is a composition of two known methods: Markov chain and Cut-Set and Tie-Set, which were extended in order to consider in calculation the dynamic adjustments of the energy levels. To evaluate the proposed method, the work performs a numerical evaluation. In addition, we evaluated the reliability of the network. The results show that the impact of saving energy might change the reliability in six decimal. The work also analyzes REASoN implemented in a network management system oriented to sustainability, called SustNMS. The results show that when the system prioritizes energy efficiency and accepts decreases on availability, the energy savings reach 43%. However, if the system prioritizes availability the energy savings reach 27%. Hence, REASoN is a powerful tool that can be used for decision making in sustainability-oriented computer networks, achieving a more accurate analysis of the impacts of saving energy.
|
446 |
APLICAÇÃO DO REGULAMENTO PARA ETIQUETAGEM DO NÍVEL DE EFICIÊNCIA ENERGÉTICA EM EDIFICAÇÃO UNIFAMILIAR PADRÃO NORMAL NA ZONA BIOCLIMÁTICA 2 BRASILEIRA / APPLICATION OF REGULATIONS FOR MARKING THE LEVEL OF EFFICIENCY IN BUILDING UNIFAMILIAR STANDARD NORMAL ZONE 2 BRAZILIAN BIOCLIMATICSoares, Roberta Mulazzani Doleys 27 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work evaluates the level of energy efficiency standard pattern, located in the brazilian bioclimatic zone 2, through the application of Quality Technical Regulation for Energy Level of Residential Buildings ( RTQ -R ) Efficiency detached buildings, having as a basis for the study city of Santiago-RS. To define the pattern of residences were adopted conceptions of NBR 12721 (ABNT, 2006), which deals with the evaluation of construction costs for real estate development , together with research and analysis project in the city of Santiago-RS. Thus, we assessed the level of energy efficiency of buildings analyzed using prescriptive methods and simulation RTQ-R being used for simulations and computational program DesignBuilder. We defined four buildings objects of study, two elongated rectangular shape with areas of 99,88m² and 142,05m², and two compact rectangular shape of 100,00m² and 168,65m². The name used for this study was based on the shape of the floor plan of the residences. The residences of elongated rectangular presented Level B and compact rectangular Level C in the envelope energy efficiency. Similarities were found in the results obtained by the two methods, especially in energy consumption for heating, presenting Levels A and B, since the degree-hour cooling was variable between levels B and C. It was observed that the buildings have discomfort during the summer. We also evaluated the influence of the thermal properties considered as prerequisites of opaque vertical locks, for it was chosen one of the residences to make alterations to the values of thermal transmittance, absorptance and solar thermal capacity. Starting from the actual data of the external walls of the building, stipulated the values to be simulated, totaling 18 simulations for determining the number of cooling degree-hours and energy consumption for heating and cooling. Thus, there was consistency in the limits of the prerequisites of the RTQ-R, however, it was observed that with low solar absorptance, increased thermal transmittance slightly affected the results, indicating greater consistency in the adoption of prerequisites that involving the thermal characteristics of the closures. / Este trabalho avalia o nível de eficiência energética de edificações unifamiliares padrão normal, localizadas na zona bioclimática 2 brasileira, através da aplicação do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Residenciais (RTQ-R), possuindo como base de estudo a cidade de Santiago-RS. Para a definição do padrão das residências adotaram-se as concepções da NBR 12721 (ABNT, 2006), que trata da avaliação de custos de construção para incorporação imobiliária, juntamente com pesquisas e análises de projeto na cidade de Santiago-RS. Dessa forma, avaliou-se o nível de eficiência energética das edificações analisadas com base nos métodos prescritivo e de simulação do RTQ-R, sendo utilizado para as simulações o programa computacional DesignBuilder. Definiram-se quatro edificações objetos de estudo, sendo duas de formato retangular alongado com áreas de 99,88m² e 142,05m², e duas de formato retangular compacto de 100,00m², e 168,65m². A denominação usada para este trabalho baseou-se no formato da planta baixa das residências. As residências de formato retangular alongado apresentaram Nível B e as de formato retangular compacto Nível C na eficiência energética da envoltória. Foram encontradas similaridades nos resultados obtidos pelos dois métodos, principalmente, no consumo de energia para aquecimento, apresentando Níveis A e B, já a variável graus-hora de resfriamento alternou entre Níveis B e C. Foi observado que as edificações possuem desconforto no período de verão. Também foi verificada a influência das propriedades térmicas consideradas como pré-requisitos dos fechamentos opacos verticais, para isto escolheu-se uma das residências para realizar as alterações dos valores de transmitância térmica, capacidade térmica e absortância solar. Partindo dos dados reais das paredes externas da edificação, estipularam-se os valores a serem simulados, totalizando 18 simulações para a determinação do número de graus-hora de resfriamento e consumo de energia para aquecimento e refrigeração. Diante disso, verificou-se a coerência dos limites dos pré-requisitos do RTQ-R, porém, foi observado que com a baixa absortância solar, o aumento da transmitância térmica pouco afetou os resultados, indicando maior conformidade na adoção de pré-requisitos que associem as características térmicas dos fechamentos.
|
447 |
Gestão energética nos setores transversais para redução do consumo de energia em uma empresa automobilística / Management energy sectors in cross for reducing power consumption in a company automotiveCastro, Alexandre Teles de [UNESP] 04 March 2016 (has links)
Submitted by ALEXANDRE TELES DE CASTRO null (axandre1@hotmail.com) on 2016-05-12T03:47:57Z
No. of bitstreams: 1
Dissertação Alexandre_27_04_2016_Versão FINAL.docx: 2706941 bytes, checksum: 571c1689b57b8c4f5187e8c13a74c86b (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-05-12T18:31:09Z (GMT) No. of bitstreams: 1
castro_at_me_guara.pdf: 2054530 bytes, checksum: 9738a869d771260980ea50f64ba32192 (MD5) / Made available in DSpace on 2016-05-12T18:31:09Z (GMT). No. of bitstreams: 1
castro_at_me_guara.pdf: 2054530 bytes, checksum: 9738a869d771260980ea50f64ba32192 (MD5)
Previous issue date: 2016-03-04 / Este trabalho visa analisar a energia elétrica das instalações elétricas, os consumos de energia elétrica, ar comprimido e água gelada, criação de novos indicadores de desempenho energético e uso de ferramentas estatísticas em uma empresa montadora de veículos. Seu principal objetivo é obter novos indicadores de desempenho energético, redução do consumo de energia elétrica em uma pesquisa ação, com a necessidade de encontrar reduções de consumo de energia nas áreas das utilidades, água gelada, água quente, ar comprimido, energia elétrica nas áreas transversais. Dentre os insumos utilizados pelas indústrias, a energia elétrica insere-se como recurso essencial em quase todas as atividades de um sistema produtivo. Dessa forma, são evidenciados os consumos de maior relevância nas áreas de utilidades e nas áreas transversais. O investimento no uso eficiente de energia elétrica traz uma série de benefícios para a empresa, para o país e para seu cliente final. Dentre os aspectos econômicos envolvidos na atividade de racionalização do uso de energia, deve-se destacar a valorização da imagem e da visão estratégica da empresa. São evidenciados os novos indicadores de desempenho energético nos setores transversais e nas utilidades, mensais. Não houve correlação dos consumos de energia elétrica entre os prédios. As tendências de consumo de ar comprimido e água gelada mostraram uma incompatibilidade, observado nos gráficos de correlação. / This work aims to analyze the demand for electric energy, electric energy consumption, compressed air and chilled water, creating new indicators of energy performance and use of statistical tools in a vehicle assembly company. Its main objective is to obtain new indicators of energy performance, reduced power consumption in an action research, with the need for energy consumption reductions in the areas of utilities, cold water, hot water, compressed air, chilled water, energy electric in cross-cutting areas. Among the inputs used by industries, the electricity is part of an essential feature in almost all activities of a production system. Thus, it is highlighted the most relevant consumption in the areas of utilities and in cross-cutting areas. Investment in energy-efficient brings a number of benefits for the company, for the country and for your end customer. Among the economic aspects involved in rationalizing activity of energy use, it should be noted to enhance the image and the strategic vision of the company. It will be shown the new energy performance indicators in cross-cutting sectors and the utilities, monthly. There was no correlation of electric energy consumption between buildings. The compressed air consumption trends and chilled water showed a mismatch, seen in correlation graphs.
|
448 |
Análise de eficiência energética de um sistema de abastecimento de água de uma indústria cimenteira / Energy efficiency analysis of a water supply system of a cement industryAmaral, Cassandra Naiff do 28 November 2013 (has links)
Made available in DSpace on 2016-08-31T13:33:38Z (GMT). No. of bitstreams: 1
CassadraNA_DISSERT.pdf: 6154828 bytes, checksum: 2ad89fa53878aa550ba1ccac38d663ba (MD5)
Previous issue date: 2013-11-28 / The Brazil is a developing nation, where economic growth is directly proportional to the consumption of the various energy sources. Thus, the trend is that demand for energy will become greater than the supply, generating a great concern about the possible lack of energy. Given this reality, government policies direct efforts to diversify the country's energy matrix. However, generate more power is not enough: there is a need, in addition to the diversification of energy sources, save on use and eliminate waste. Within this context, the industrial sector is considered the highest energy consumption, where the main source is electricity consumed. In the specific case of the cement industry, electricity accounts for the second largest source of consumption and its use is practically all for the driving force, which in turn, has a high potential for energy efficiency. Thus, in order to analyze the energy performance of a cement industry by eliminating the waste of electricity, studies have been conducted and identified points of improvements in water supply system of a cement factory with a capacity of 10 million bags of cement per year. As part of the research and energy efficiency solutions, has deployed a new automation project, which provided the achievement of improvements in the operation, control, supervision and system measurements and their electrical parameters. These improvements were made possible due to the development and application of logical control for the level of general water tank and deployment of new technologies and to control the drive of centrifugal pumps. Results showed that the activation of the centrifugal pumps through frequency inverters is more efficient than the direct drive type match and / or soft-start. How to control the level of the general reservoir, it was evident that the Control type Proportional, Integral and Derivative maintains the level of the general constant reservoir and pump operation in continuous, without increasing power consumption. Thus, it has become the most suitable for achieving energy efficiency in the factory Water Supply System / O Brasil representa uma nação em desenvolvimento, onde seu crescimento econômico é diretamente proporcional ao consumo das diversas fontes de energia. Assim, a tendência é que a demanda por energia se torne maior que a oferta, gerando uma grande preocupação com a possível falta de energia. Diante dessa realidade, as políticas governamentais direcionam esforços para diversificar a matriz energética do país. No entanto, gerar mais energia não é suficiente: existe a necessidade de, além da diversificação das fontes de energia, economizar no uso e eliminar o desperdício. Dentro deste contexto, o setor industrial é considerado o de maior consumo de energia, onde a principal fonte consumida é a eletricidade. No caso específico da indústria cimenteira, a energia elétrica corresponde a segunda maior fonte de consumo e seu uso é praticamente todo destinado à força motriz, que por sua vez, apresenta alto potencial de eficiência energética. Assim, com o objetivo de analisar o desempenho energético de uma indústria de cimento através da eliminação do desperdício de energia elétrica, foram realizados estudos e identificados pontos de melhorias no Sistema de Abastecimento de Água de uma cimenteira com capacidade de 10 milhões de sacos de cimento por ano. Como parte da pesquisa e soluções de eficiência energética, foi implantado um novo projeto de automação, que proporcionou a realização de melhorias na operação, controle, supervisão e medições do sistema e suas respectivas grandezas elétricas. Essas melhorias foram possíveis, devido ao desenvolvimento e aplicação de lógicas de controle para o nível do reservatório de água geral e implantação de novas tecnologias e controle para o acionamento das bombas centrífugas. Os resultados comprovaram que o acionamento das bombas centrífugas através de inversores de frequência é mais eficiente que os acionamentos tipo partida direta e/ou soft-start. Quanto ao controle do nível do reservatório geral, ficou evidenciado que o Controle tipo Proporcional, Integral e Derivativo mantém o nível do reservatório geral constante e a operação da bomba em regime contínuo, sem aumentar o consumo de energia elétrica. Dessa forma, o mesmo tornou-se o mais indicado para obtenção de Eficiência Energética no Sistema de Abastecimento de Água da fábrica
|
449 |
Dispositivos de proteção solar e eficiência energética em edifícios de escritório : uma avaliação para a cidade de Maceió/AL. / Solar shading devices and office buildings energy efficiency : an evaluation for Maceió city, Brazil.Martins, Thiago Luiz de Oliveira Gomes 07 December 2007 (has links)
Since the oil energy crisis of the seventies until the Brazilian 2001 blackout, energy savings
became an important issue in Brazil and the building industry has been identified as a sector
where substantial savings may occur. In commercial buildings the energy consumption is
strongly related to air conditioning systems. Facing this context, the present work intends to
evaluate the impact of using solar shading devices in the energy consumption performance of
medium size typical office buildings located in Maceió city, Brazil. In low latitude regions,
solar radiation represents an important parcel of buildings total heat gain. The evaluation was
carried out through a parametric investigation where the effect of facades orientation and
typology in the energy consumption, as well as the effect of plan typology regarding the
location of corridor (central or lateral). Computer simulations of models representing the
combinations for parameters above mentioned were carried out using the Energyplus software
in order to estimate the energy consumption of each model. The simulations have shown the
energy consumption for the considered models, allowing for the estimation of the impact
magnitude regarding each of the different examined parameters. When solar shading devices
were added to facades built in masonry with exposed windows the energy savings related to
air conditioning systems was 18.7%, while for curtain wall facades it reached 39.2%. Results
lead to the conclusion that the use of solar shading devices represents a relevant design
strategy for energy savings in office buildings located in Maceió. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Desde a crise do petróleo nos anos de 1970 até o colapso energético de 2001 a conservação de
energia passou a ser alvo de discussões no Brasil e o setor da construção civil foi identificado
como um campo de grande potencial de combate ao desperdício energético. Nas edificações
comerciais o consumo energético está fortemente relacionado aos sistemas artificiais de
geração de conforto ambiental como os sistemas artificiais de condicionamento térmico, por
exemplo. Diante deste contexto, o presente trabalho avalia o impacto decorrente da utilização
dos dispositivos de proteção solar para o desempenho energético de edificações que
representam as características típicas dos edifícios de escritórios de médio porte localizados
na cidade de Maceió/AL. Sabe-se que nestas regiões, de baixa latitude, a radiação solar
representa uma parcela significativa no calor total que atinge as edificações. Para tal, adotouse
uma metodologia de análises paramétricas nas quais foi comparado o desempenho
energético das edificações sob diversas condições de orientação geográfica, tipologia de
fechamento de fachada e localização do corredor de circulação horizontal (central e lateral).
Os índices de consumo energético foram obtidos a partir de simulações com modelos
computacionais utilizando o software Energyplus. As simulações realizadas permitiram
quantificar e classificar o desempenho energético das edificações, sob as diversas
características construtivas estudadas. A inclusão dos dispositivos de proteção solar
representou, em alguns casos, para os sistemas artificiais de condicionamento térmico,
economia energética anual de 18,7% no comparativo com as edificações com fachada em
alvenaria e janela exposta e, 39,2% no comparativo com edificação com fechamento de
fachada em pele de vidro. Desta forma conclui-se que a utilização dos dispositivos de
proteção solar apresenta-se como uma alternativa de adequação climática e de redução de
consumo energético bastante eficiente para edificações localizadas na cidade de Maceió.
|
450 |
Conforto térmico e eficiência energética em edifício multifamiliar na cidade de Maceió-AL. / Thermal comfort and energy efficiency in multifamily building in Maceió-AL.Almeida, Alana Mello de 30 March 2009 (has links)
The human comfort is longed incessantly. That, is linked to the shelter, protection against the intemperies and climate severity, always for well-being purposes the human comfort can be analysed by several optics. This work dedicates itself, specifically, to study the comfort under the thermal aspects, not only as a salutary requisite of architecture, but also the valuable quality regarding to the habitation, considering your influence in respect to the energy efficiency. The study developed in this research focused the analysis of a residential multifamiliar building in the residential quarter of Ponta Verde, in the city of Maceio-AL, which suffers constant transformation, new buildings arise at every moment in places that were no longer occupied by unifamiliar residences. These buildings, seems, that are projected and built without themal comfort and energy consumption preocupations, and, consequently, it reflexes to the human being and the environment. The analysis has been effectuated qualitative and quantitatively based theoretical references pertinent to the climatic, humans and architectonics variables, searching fundamental in bioclimatic architecture approach, your strategies and influences in the sustainability and energy consumption. It was evidenced that the apartments oriented in the east presented a better performance that the west ones in relation of thermal comfort, and, consequently of energy efficiency. Certainly, doubt, the world today lives a critic moment in respect to the energy crisis. It is perceived that the architecture can be used in a favourable way at this question. Therefore, is imperative to build new paradigms, capables to harmonize built environment and nature, in favour of a sustainable future. / O conforto é almejado pelo homem. Esse, está ligado ao abrigo, proteção contra as intempéries e rigores do clima, visando sempre seu bem-estar. O conforto pode ser analisado sob várias ópticas. Este trabalho dedica-se, especificamente, a estudá-lo sob o aspecto térmico, não só como requisito salutar da arquitetura, como também qualidade valiosa no tocante à habitação, considerando-se sua influência em relação à eficiência energética. O estudo desenvolvido nesta pesquisa analisou um edifício residencial multifamiliar no bairro da Ponta Verde, na cidade de Maceió-Al, no qual, em permanente transformação, novos edifícios surgem constantemente em lugares antes ocupados por residências unifamiliares. Esses edifícios, ao que parece, são projetados e construídos sem maiores preocupações quanto ao conforto térmico e ao consumo energético, e, consequentemente, a seus reflexos relativos ao ser humano e ao meio ambiente. A análise foi efetuada qualitativa e quantitativamente com base nos referenciais teóricos relativos às variáveis climáticas, humanas e arquitetônicas, buscando fundamento nos alicerces da arquitetura bioclimática, suas estratégias e influências na sustentabilidade e no consumo energético. Constatou-se que os apartamentos orientados a Leste apresentaram um desempenho superior aos do Oeste em termos de conforto térmico, consequentemente de eficiência energética. Sem dúvida, vive-se um momento crítico em relação à crise energética. É pacífico que a Arquitetura pode ser explorada de forma favorável a essa questão. Portanto, é imperativo construir novos paradigmas, capazes de harmonizar ambiente construído e natureza, em prol de um futuro sustentável.
|