1501 |
Adaptometria de escuro para estudos de retinaStefenon, M?rcio 19 December 2013 (has links)
Made available in DSpace on 2015-04-14T13:56:31Z (GMT). No. of bitstreams: 1
458958.pdf: 7355419 bytes, checksum: 8a2fa20967c4240f1bb187644d3207a4 (MD5)
Previous issue date: 2013-12-19 / Vision is one of the most important senses of man. Many diseases that affect the sense
of vision are related to the retina. Some of these diseases specifically affecting the
photoreceptors, light-sensitive cells that is the first stage of vision.
The examinations of dark adaptation have motivated interest in the study of mechanisms of
retinal diseases. This exam directly accesses the functions of the photoreceptors by noninvasive
methods. The technique consists in measuring the time to recovery of sensitivity of
the retina after exposing the retina to a controlled amount of light.
The dark adaptometry equipment is used to monitor the response of these cells to a
light stimulus and then reveal some deficiency in the operation.
This work describes the procedures, calculations, measurements and verifications necessary
for the calibration of an existing dark adaptometer. This equipment was developed in the
Image Laboratory at PUCRS, led by Professor Dario Azevedo, Ph.D. from a modified fundus
camera. This dark adaptometer is able to test localized regions of the retina, while visualizing
the regions of interest, and therefore compensating for any eye movements.
For calibration of dark adaptometer, various calculations based on literature review was
conducted. After using instruments such as spectrometer, radiometer, and light meter
luminometer dark adaptometer was calibrated. The operation of each block that makes up this
instrument was checked.
Measurements of illuminance values of the light stimulus, retinal luminance
attenuation of dark adaptometer, attenuation imposed by optical fiber, was observed
throughout the range of attenuation filters (0 dB to 60 dB), also checked the operation of the
wheels were made and a shutter that filters are controlled by the motor steps.
The dark adaptometer met all specifications, i.e., the values set in the calculations in this work
has been achieved. / A vis?o ? um dos mais importantes sentidos do homem. Muitas doen?as que afetam o sentido
da vis?o est?o relacionadas com a retina. Algumas dessas doen?as afetam especificamente os
fotorreceptores, c?lulas sens?veis ? luz, que ? o primeiro est?gio da vis?o.
Os exames de adapta??o ao escuro t?m motivado o interesse no estudo de mecanismos de
doen?as de retina. Esse exame acessa diretamente as fun??es dos fotorreceptores por m?todos
n?o invasivos. A t?cnica consiste, em medir o tempo de recupera??o da sensitividade da
retina, depois de expor a retina a uma quantidade controlada de luz.
Um equipamento de adaptometria ao escuro ? utilizado para monitorar a resposta destas
c?lulas a um est?mulo luminoso e ent?o revelar alguma defici?ncia no funcionamento.
Neste trabalho, est?o descritos os procedimentos, c?lculos, medidas e verifica??es necess?rias
para a calibra??o de um adapt?metro de escuro j? existente. Este equipamento foi
desenvolvido no Laborat?rio de Imagens da PUCRS, liderado pelo professor Dario Azevedo
Ph.D. a partir de uma c?mera de fundus modificada. Este adapt?metro de escuro ? capaz de
testar, de forma localizada, regi?es da retina permitindo, a crit?rio do examinador testar e
mapear exclusivamente as regi?es que forem do seu interesse e compensar eventuais
movimentos oculares.
Para a calibra??o do adapt?metro de escuro, foi realizados diversos c?lculos com base na
revis?o bibliogr?fica. Ap?s, utilizando instrumentos como espectrofot?metro,
espectroradi?metro, lux?metro e luminanc?metro o adapt?metro de escuro foi calibrado. Foi
verificado o funcionamento de cada bloco que comp?e este instrumento.
Foram realizadas as medidas dos valores de ilumin?ncia do est?mulo luminoso, lumin?ncia
retinal, atenua??es do adapt?metro de escuro, atenua??o impostas pela fibra ?ptica, foi
verificado toda a faixa de atenua??o dos filtros (0 dB at? 60 dB), tamb?m verificado o
funcionamento das rodas de filtros e do shutter que s?o comandados pelos motores de passos.
O adapt?metro de escuro atendeu todas as especifica??es, ou seja, os valores definidos nos
c?lculos neste trabalho foram atingidos.
|
1502 |
Desenvolvimento de um I-IP para o monitoramento da atividade do sistema operacional em processadores multin?cleosOliveira, Chr?stofer Caetano de 21 March 2014 (has links)
Made available in DSpace on 2015-04-14T13:56:31Z (GMT). No. of bitstreams: 1
459325.pdf: 2898170 bytes, checksum: 16df18a4b13e444ddaa394a95eaebeae (MD5)
Previous issue date: 2014-03-21 / The use of Real-Time Operating System (RTOS) became an attractive solution to design safety-critical real-time embedded systems. At the same time, we enthusiasti-cally observe the widespread use of multicore processors in an endless list of our daily applications. It is also a common agreement the increasing market pressure to reduce power consumption under which these embedded, portable systems have to operate. As the major consequence, these systems are becoming more and more sensitive to transi-ent faults originated from a large spectrum of noisy sources such as conducted and radi-ated Electromagnetic Interference (EMI) and ionizing radiation (single-event effect: SEE and total-ionizing dose: TID). Therefore, the system s reliability degrades. In this work, we discuss the development and validation of an Infrastructure-Intellectual Prop-erty (I-IP) able to monitor the RTOS activity in a multicore processor system-on-chip. The final goal is to detect faults that corrupt the task scheduling process in embedded systems based on preemptive RTOS. Examples of such faults could be those that pre-vent the processor from attending an interruption of higher priority, tasks that are strict-ly allocated to run on a given core, but are running on another one, or even the execu-tion of low-priority tasks that are passed over high-priority ones in the ready-task list maintained on-the-fly by the RTOS. This I-IP, namely RTOS-Watchdog, was described in VHDL and is connected to each of the processor CPU-Addresses busses. The RTOS Watchdog has a parameterizable interface to easily fit any processor bus. A case-study based on a multicore processor running different test programs under the control of a typical preemptive RTOS was implemented. The case-study was prototyped in a Xilinx Virtex4 FPGA mounted on a dedicated platform (board plus con-trol software) fully developed at the Computing Signals & Systems Group (SiSC) [1] of the Catholic University (PUCRS). For validation, the whole system was exposed to combined effects of EMI and TID. Such experiments were performed in several steps, part of them carried out at PUCRS, Brazil, and part at the Instituto Nacional de Tecnolog?a Industrial (INTI) and Centro At?mico, both located in the city of Buenos Aires, Argentina. The obtained results demonstrate that the proposed approach provides higher fault coverage and reduced fault latency when compared to the native fault detec-tion mechanisms embedded in the kernel of the RTOS. / O uso de sistemas operacionais de tempo real (Real-Time Operating Systems, RTOS), tornou-se uma solu??o atrativa para o projeto de sistemas embarcados cr?ticos de tempo real. Ao mesmo tempo, observamos com entusiasmo o amplo uso de proces-sadores multicores em uma lista intermin?vel de nossas aplica??es di?rias. ? tamb?m um acordo comum a crescente press?o do mercado para reduzir o consumo de energia em que estes sistemas port?teis embarcados necessitam para operar. A principal conse-qu?ncia ? que estes sistemas est?o se tornando cada vez mais suscet?veis ? falhas transi-entes originadas por um amplo espectro de fontes de ru?dos como Interfer?ncia Eletro-magn?tica (Electromagnetic Interference, EMI) conduzida e irradiada e radia??o ioni-zante (single-event transient: SET e total-ionizing dose: TID). Portanto, a confiabilidade destes sistemas ? degradada. Nesta disserta??o, discute-se o desenvolvimento e valida-??o de um I-IP (Infrastructure-Intellectual Property) capaz de monitorar a atividade do RTOS em um processador multicore. O objetivo final ? detectar falhas que corrompem o processo de escalonamento de tarefas em sistema sistemas embarcados baseados em RTOS preemptivos. Como exemplo destas falhas podem ser aquelas que impedem o processador de atender uma interrup??o de alta prioridade, tarefas alocadas para serem executadas por um determinado n?cleo, mas que s?o executadas por outro n?cleo, ou at? a execu??o de tarefas de baixa prioridade enquanto houver tarefas de alta prioridade na lista de tarefas prontas atualizada dinamicamente pelo RTOS. Este I-IP, chamado RTOS Watchdog, foi descrito em VHDL e ? conectado ao Barramento de Endere?os da CPU em cada n?cleo do processador. O RTOS Watchdog possui uma interface parame-triz?vel de modo a facilitar a adapta??o a qualquer processador. Um estudo de caso baseado em um processador multicore executando diferen-tes benchmarks sob o controle de um RTOS preemptivo t?pico foi desenvolvido. O es-tudo de caso foi prototipado em uma FPGA Xilinx Virtex4 montada em uma plataforma dedicada (placa mais software de controle) totalmente desenvolvida no Grupo Compu-ting Signals & Systems (SiSC) [1] da Pontif?cia Universidade Cat?lica do Rio Grande do Sul (PUCRS). Para a valida??o, todo o sistema foi exposto aos efeitos combinados de EMI e TID. Estes experimentos foram realizados em diversos passos, parte deles foram realizados na PUCRS, Brasil e parte no Instituto Nacional de Tecnologia Industrial (INTI) e Centro At?mico, ambos na cidade de Buenos Aires, Argentina. Os resultados demonstram que a abordagem proposta fornece uma maior cobertura de falhas e lat?ncia de falhas reduzida quando comparados aos mecanismos de detec??o de falhas nativos embarcados no kernel do RTOS.
|
1503 |
Desenvolvimento de uma c?mara de press?o positiva para estudos em fisiologia espacialDisiuta, Leandro 30 April 2014 (has links)
Made available in DSpace on 2015-04-14T13:56:31Z (GMT). No. of bitstreams: 1
460260.pdf: 4336940 bytes, checksum: dca359fe8c5ae44e193444e9c8fcfd08 (MD5)
Previous issue date: 2014-04-30 / Missions to Mars and return astronauts to the Moon may be true in the near future, which will expose them upon hypogravity environments. Some techniques are applied to simulate gravitational force reduced to prepare the crew to better adapt to those environments. This study aimed to develop a prototype of a lower body positive pressure (LBPP), as an alternative to the simulations currently used. This device is able to unload a volunteer on a physical exercise device, creating a hypogravity environment, simulating the human gait, for studies in space physiology. For development of the LBPP was necessary planning since its conception until the final prototype with functionality testing. A control system has been implemented for closed-loop pressure control. Equipment were identified and adapted such as blower, frequency inverter to control the blower, sensors (pressure, temperature and humidity), load cells to measure apparent weight of volunteer, microcontroller, treadmill for gait simulation and Neoprene short for connection of volunteer to a Neoprene membrane. Equipment and instrumentation were also developed to integrate and facilitate the system. Was developed the main chamber of a flexible PVC material, a metallic structure for height adjustment. Also was developed the instrumentation of load cells, as well as instrumentations of the sensors to adapt and read by the microcontroller. Furthermore it was necessary to develop software for data acquisition, the instrumentation of the blower and the frequency inverter to digital control by the microcontroller and an emergency circuit to ensure safety operation of the equipment. Experimental results shown that the LBPP is able to reduce the apparent weight of a load with similar weight values on Mars and the Moon, reaching the goal, where it was possible to verify that the pressure ratio and apparent weight is inversely proportional, which confirmed the theory. / Miss?es tripuladas para Marte e o retorno a Lua poder?o concretizar-se em um futuro pr?ximo, onde ir?o expor os astronautas a ambientes de hipogravidade. T?cnicas de redu??o da for?a gravitacional s?o aplicadas como medidas para prepara??o da tripula??o a uma melhor adapta??o a tais ambientes. O presente trabalho objetivou desenvolver um prot?tipo funcional de uma c?mara de press?o positiva (CPP), sendo uma alternativa ?s simula??es utilizadas atualmente. Tal dispositivo ? capaz de diminuir o peso aparente do volunt?rio sobre um sistema de exerc?cios f?sicos, gerando um ambiente de hipogravidade para estudos em fisiologia espacial. Para o desenvolvimento da CPP foi necess?rio um planejamento desde sua idealiza??o at? o prot?tipo final com testes de funcionalidade. Primeiramente foi idealizado um sistema de controle em malha-fechada para o controle da press?o. Para isso foram identificados e adaptados diversos equipamentos como soprador, inversor de frequ?ncia para o controle do soprador, sensores de press?o, temperatura e umidade, c?lulas de carga para mensurar o peso aparente do volunt?rio, microcontrolador, esteira ergom?trica para simula??o da marcha em hipogravidade e um short para conectar o volunt?rio ? membrana de Neoprene. Equipamentos e instrumenta??o tamb?m foram desenvolvidos para integrar e viabilizar o sistema. Foi desenvolvida uma c?mara composta de material flex?vel de PVC, uma estrutura met?lica para ajuste de altura e tamb?m instrumenta??o das c?lulas de carga e dos sensor de press?o, temperatura e umidade para adapta??o e leitura pelo microcontrolador. Al?m disso foi necess?ria o desenvolvimento de um software para aquisi??o de dados a instrumenta??o do soprador e do inversor de frequ?ncia para o controle digital do microcontrolador e um circuito de emerg?ncia para garantir a seguran?a do volunt?rio. Resultados experimentais mostram que a CPP ? capaz de diminuir o peso aparente de uma carga com valores semelhantes ao peso em Marte e Lua, atingindo seu objetivo, onde foi poss?vel verificar que a rela??o de press?o e peso aparente ? inversamente proporcional, confirmando a teoria.
|
1504 |
Automa??o e controle da caixa de press?o negativa de membros inferioresCambraia, Rodrigo Reckziegel 16 January 2014 (has links)
Made available in DSpace on 2015-04-14T13:56:32Z (GMT). No. of bitstreams: 1
460448.pdf: 5951570 bytes, checksum: afed14c2ca9f2963cc42ed8d5fb7baaa (MD5)
Previous issue date: 2014-01-16 / The use of equipment "lower body negative pressure box" (LBNP) is a instrument of great importance to the scientific community health sciences. Initially used for simulation of orthostatic stress in space agencies studies on the physiological performance, today it has a range of applications to be study. In mid-2002, a LBNP Box was developed at the Center for Microgravity Laboratory, but it became outdate and out of use.This work was done to modernize pneumatic, electrical, electronic systems and the application interface. The realized retrofit enables the equipment for research use in the area of Aerospace Medicine on orthostatic intolerance of the cardiovascular system. Auniversal process controller with PID control technique was used with a classical tuning control proposed in the first method of Ziegler and Nichols. / O uso do equipamento lowerbody negative pressureBox (LBNP- caixa de press?o negativa) ? de grande import?ncia para a comunidade cient?fica das ci?ncias da sa?de. Inicialmente utilizado para simula??o de estresse ortost?tico em estudos sobre o comportamento fisiol?gico pelas ag?ncias espaciais, hoje j? tem sua gama de aplica??es para estudo. Em meados de 2002 uma LBNP foi desenvolvida no Laborat?rio do Centro de Microgravidade, por?m ela ficou desatualizada e inoperante. O presente foi realizado para modernizar ossistemas pneum?tico, el?trico, eletr?nico assim como o aplicativo de interface. O retrofit realizado deixou o equipamento em condi??es para o uso em pesquisas na ?rea de Medicina Aeroespacial sobre intoler?ncia ortost?tica do sistema cardiovascular. Um controlador universal de processos com controle do tipo PID utilizando t?cnica de controle cl?ssico de sintonia proposto no primeiro m?todo de Ziegler e Nichols.
|
1505 |
Confiabilidade em resson?ncia magn?tica funcional no estado de repouso em diferentes estrat?gias de pr?-processamentoAurich, Nathassia Kadletz 22 August 2014 (has links)
Made available in DSpace on 2015-04-14T13:56:33Z (GMT). No. of bitstreams: 1
463003.pdf: 2663394 bytes, checksum: 0158a49caa9b116197cb1f3a76c44980 (MD5)
Previous issue date: 2014-08-22 / Resting State functional Magnetic Resonance Imaging (rs-fMRI) provides information
about the functional connectivity of brain areas. However, prior to calculating the functional
connectivity of the brain, there is a choice of several preprocessing steps that need to be
selected. A critical source of variation between studies arises from distinct preprocessing
approaches prior to the functional connectivity analysis. Therefore, a study to examine the
reliability of different methods for pre-processing data from rs-fMRI is necessary. In this
study, seven preprocessing strategies were tested and the reliability was evaluated between
them in Graph Theoretical (GT). The sample used in this study is from a public database and
consists of control subjects. Measures of GT were calculated using different strategies, after
applying a method of subdividing the brain into 190 regions of interest. The following
measures were calculated: global efficiency, characteristic path length, clustering coefficient
and local efficiency. The results indicate that there is a significant difference in measurements
of GT depending on the preprocessing strategy selected. It was also found that noise
estimation parameters are correlated with GT measures. Moreover, it is observed that the level
of thresholding chosen in the connectivity matrix can affect the measurements of GT,
therefore further studies regarding this topic are needed. It was concluded, based on the
sample used in this work that the method of scrubbing by outliers could increase the
reliability of measurements of GT and reduce dependence on the movement of the patient's
head. / A Resson?ncia Magn?tica Funcional no estado de repouso (rs-fMRI, do ingl?s resting state
functional Magnetic Resonance) permite obter informa??es a respeito das ?reas de
conectividade funcional do c?rebro. Por?m, a visualiza??o dessa conectividade s? ? poss?vel
ap?s aplicar uma s?rie de etapas de processamento de imagens antes que se possa avaliar a
conectividade cerebral. Considerando a limita??o na quantifica??o dos dados de rs-fMRI, e
sabendo que uma fonte de varia??o cr?tica para a compara??o entre os estudos ? o fato de cada
um deles remover, incluir ou mudar par?metros nos passos de pr?-processamento de rs-fMRI,
? necess?rio um estudo para analisar a confiabilidade de diferentes metodologias de pr?processamento
de dados de rs-fMRI. Para tanto, a Teoria dos Grafos (TG) foi utilizada como
par?metro final para avaliar a conectividade. Neste presente trabalho, foram testadas sete
estrat?gias de pr?-processamento e foi avaliada a confiabilidade entre elas quando s?o feitas
medidas de TG. A amostra utilizada neste trabalho ? de uma base de dados p?blica e ?
composta por indiv?duos controle. As medidas de TG foram calculadas nas diferentes
estrat?gias, ap?s aplicar um m?todo de parcelamento do c?rebro em 190 regi?es. Foram
calculadas as seguintes medidas: efici?ncia global, comprimento do caminho caracter?stico,
coeficiente de agrupamento e efici?ncia local. Os resultados indicaram que existe uma
diferen?a significativa nas medidas de teoria dos grafos quando o pr?-processamento ? feito
de diferentes maneiras. Foi encontrado tamb?m que par?metros de estimativa de ru?do s?o
correlacionados com as medidas de TG. Al?m disso, observa-se que o n?vel de limiariza??o
escolhido na matriz de conectividade pode afetar significativamente as medidas de TG, sendo
necess?rio um estudo mais aprofundado a respeito deste tema. Concluiu-se, baseado na
amostra utilizada neste trabalho, que o m?todo de scrubbing por outliers pode aumentar a
confiabilidade das medidas de TG e reduzir a sua depend?ncia com o movimento da cabe?a
do paciente.
|
1506 |
Estudo da estrat?gia de harmoniza??o da quantifica??o do SUV em imagens de PET/CTFischer, Andr?ia Caroline Fischer da Silveira 25 August 2014 (has links)
Made available in DSpace on 2015-04-14T13:56:33Z (GMT). No. of bitstreams: 1
462943.pdf: 4086036 bytes, checksum: 8b6abefa3b76b3bc43dbf4ca084a593b (MD5)
Previous issue date: 2014-08-25 / In clinical practice, PET/CT images are often analyzed qualitatively by visual comparison of tumor lesions and normal tissues uptake; and semi-quantitatively by means of a parameter called SUV (Standardized Uptake Value). To ensure that longitudinal studies acquired on different scanners are interchangeable, and information of quantification is comparable, it is necessary to establish a strategy to harmonize the quantification of SUV. The aim of this study is to evaluate the strategy to harmonize the quantification of PET/CT images, performed with different scanner models and manufacturers. For this purpose, a survey of the technical characteristics of equipment and acquisition protocols of clinical images of different services of PET/CT in the state of Rio Grande do Sul was conducted. For each scanner, the accuracy of SUV quantification, and the Recovery Coefficient (RC) curves were determined, using the reconstruction parameters clinically relevant and available. From these data, harmonized performance specifications among the evaluated scanners were identified, as well as the algorithm that produces, for each one, the most accurate quantification. Finally, the most appropriate reconstruction parameters to harmonize the SUV quantification in each scanner, either regionally or internationally were identified. It was found that the RC values of the analyzed scanners proved to be overestimated by up to 38%, particularly for objects larger than 17mm. These results demonstrate the need for further optimization, through the reconstruction parameters modification, and even the change of the reconstruction algorithm used in each scanner. It was observed that there is a decoupling between the best image for PET/CT qualitative analysis and the best image for quantification studies. Thus, the choice of reconstruction method should be tied to the purpose of the PET/CT study in question, since the same reconstruction algorithm is not adequate, in one scanner, for qualitative and quantitative assessments in different scopes. We concluded that the harmonization strategy of the SUV quantification presented in this paper was effective in reducing the variability of small structures quantification. However, for the comparison of SUV quantification between different scanners and institutions, it is essential that, in addition to the harmonization of quantification, the standardization of the methodology of patient preparation is maintained, in order to minimize the SUV variability due to biological factors. / Na rotina cl?nica, imagens de PET/CT, costumam ser analisadas qualitativamente, mediante a compara??o visual entre a capta??o nos tecidos hipercaptantes e nos tecidos normais; e, semiquantitativamente, por meio de um par?metro denominado SUV (do ingl?s Standardized Uptake Value). Para garantir que estudos longitudinais adquiridos em distintos equipamentos sejam intercambi?veis e informa??es de quantifica??o sejam compar?veis, torna-se necess?rio o estabelecimento de uma estrat?gia de harmoniza??o da quantifica??o do SUV. O objetivo geral deste estudo ? avaliar uma estrat?gia de harmoniza??o da quantifica??o de imagens de PET/CT, realizada com equipamentos de diferentes modelos e fabricantes. Para tanto, foi realizado um levantamento das caracter?sticas t?cnicas do equipamento e dos protocolos de aquisi??o das imagens cl?nicas de distintos servi?os de PET/CT do estado do Rio Grande do Sul. Para cada equipamento, foram determinadas a acur?cia da quantifica??o do SUV e as curvas de Coeficiente de Recupera??o (RC, do ingl?s Recovery Coefficient), utilizando os par?metros de reconstru??o clinicamente dispon?veis e relevantes. A partir desses dados, foram identificadas as especifica??es de desempenho harmoniz?veis dentre os equipamentos avaliados, assim como o algoritmo que produz, em cada equipamento, a quantifica??o mais acurada. Finalmente, foram identificados os par?metros de reconstru??o mais adequados ? harmoniza??o da quantifica??o do SUV em cada equipamento, em ?mbito regional e internacional. Constatou-se que os valores de RC dos equipamentos analisados mostraram-se superestimados em at? 38%, particularmente para objetos de dimens?es maiores do que 17 mm. Estes resultados mostram a necessidade de uma otimiza??o, mediante a modifica??o dos par?metros de reconstru??o utilizados e at? mesmo da mudan?a do algoritmo de reconstru??o utilizado em cada equipamento. Observou-se que existe uma dissocia??o entre a melhor imagem para an?lise qualitativa e a melhor imagem para quantifica??o dos estudos de PET/CT. Assim, a escolha do m?todo de reconstru??o deve estar atrelada ? finalidade do estudo de PET/CT em quest?o, visto que um mesmo algoritmo de reconstru??o n?o se mostra adequado, em um ?nico equipamento, ?s avalia??es qualitativas e quantitativas, em diferentes ?mbitos. Conclui-se que a estrat?gia de harmoniza??o da quantifica??o do SUV apresentada neste trabalho mostrou-se eficaz na redu??o da variabilidade da quantifica??o de pequenas estruturas. Entretanto, para que a quantifica??o do SUV possa ser comparada entre diferentes equipamentos e institui??es, ? fundamental que, al?m da harmoniza??o da quantifica??o, seja mantida a padroniza??o da metodologia de preparo do paciente, visando minimizar a variabilidade atribu?da ao SUV decorrente de fatores biol?gicos.
|
1507 |
Aloca??o de canais em uma rede de r?dios cognitivos gerenciada por base de dados preditiva adaptativaRibeiro, Sandro Machado 27 October 2014 (has links)
Made available in DSpace on 2015-04-14T13:56:34Z (GMT). No. of bitstreams: 1
464757.pdf: 15490985 bytes, checksum: 69a8a4405f520c0450487a75c04a1117 (MD5)
Previous issue date: 2014-10-27 / This work proposes a channel allocation methodology in a cognitive radio network (CRN) that uses a predictive and adaptive channel database. A spectrummodeling algorithm, that allows simulating channel occupation in cellular technology bands, generates the prediction data. The use of prediction enables the identification of opportunities in the bands of interest, which allows prioritizing the use of those channels with greater probability of being idle. Thus, this work extends the scope of IEEE 802.22, in that proposes the use of prediction data, as well as the use of cellular technology bands, which are commonly used in urban areas. The adaptive nature of the developed system updates the channel list dynamically over the allocation cycles. This feature enables to prioritize the channels with greater success in the allocation process, since the channel list is updated according to the results of secondary users (SUs) allocation. The proposed methodology aims to allocate the SU with the minimum of channel sensing operations required. The adaptive feature of the channel database gives a major contribution to reducing the channel sensing operations in the CRN. The decrease in channel sensing operations reduces the exchange of information between the functions that comprise the cognitive plane of a CRN. Consequently, a reduction in the network signaling traffic is expected, as well as a reduction of delays resulting from the search of available channels. / O presente trabalho prop?e uma metodologia de gerenciamento de canais numa rede de r?dios cognitivos (CRN) que utiliza uma base de dados de canais preditiva e adaptativa. Os dados de predi??o s?o gerados por um algoritmo de modelagem de espectro que permite simular a ocupa??o dos canais em faixas de tecnologia celular. O uso de predi??o possibilita a identifica??o de oportunidades nas bandas de interesse, permitindo priorizar a utiliza??o dos canais com maior probabilidade de estarem livres. Dessa forma, este trabalho estende a abrang?ncia da IEEE 802.22, na medida em que prop?e o uso de dados de predi??o, bem como a utiliza??o de faixas de tecnologia celular que s?o comumente utilizadas em ?reas urbanas. O car?ter adaptativo do sistema desenvolvido atualiza a lista de canais de forma din?mica ao longo dos ciclos de aloca??o. Esta caracter?stica possibilita a prioriza??o dos canais com maior sucesso no processo de aloca??o, uma vez que a lista de canais ? atualizada de acordo com os resultados das aloca??es dos usu?rios secund?rios (SUs). A metodologia proposta busca realizar a aloca??o do SU com o m?nimo necess?rio de opera??es de detec??o de canal. A adaptabilidade da base de dados de canais ? o fator que possui maior contribui??o na redu??o das opera??es de detec??o de canal na CRN. A diminui??o das opera??es de detec??o de canal reduz a troca de informa??es entre as fun??es que comp?em o plano cognitivo de uma CRN. Consequentemente, uma redu??o no tr?fego de sinaliza??o da rede ? esperada, assim como uma diminui??o de atrasos resultantes da busca de canais dispon?veis.
|
1508 |
Sistema para est?mulo olfativo em estudos de neuroimagemFachel, Fl?via Nathiely Silveira 15 January 2015 (has links)
Made available in DSpace on 2015-04-14T13:56:34Z (GMT). No. of bitstreams: 1
464986.pdf: 769829 bytes, checksum: 49435c45502b8b8d745ac315c7c4ac12 (MD5)
Previous issue date: 2015-01-15 / In the last three decades, neuroimaging studies have provided significant
advances in knowledge of the human brain, especially of brain areas hitherto little
explored, such as olfaction. Many factors have been reported as able to alter the
olfactory threshold and, more recently, the clinical relevance related to changes in
this threshold has been largely addressed, principally in relation to
neurodegenerative diseases. In parallel, many industries have sought innovative
tools for assessing the impact of aromas in the population. Given the lack of
adequate national tools for these applications, the present research aimed to develop
a robust, automated and instrumented method for olfactory stimuli in neuroimaging
studies, with a man-machine interface able to control and visualize the function in a
user-friendly way. The results showed that the system was instrumented in a manner
compatible with the functional magnetic resonance imaging environment.
Furthermore, it nebulized the aromatic sample homogeneously and presented a
similar velocity and flow of the air in the three valves. Therefore, this instrument will
be able to help identify the mechanisms involved in olfactory threshold change in
different situations and may provide important clinical advances. Additionally, it can
be an auxiliary tool in business marketing strategies. / Os estudos de neuroimagem, nas ?ltimas tr?s d?cadas, proporcionaram
avan?os significativos no conhecimento do c?rebro humano, especialmente, de
?reas cerebrais at? ent?o pouco exploradas, como, o olfato. Muitos fatores t?m sido
referidos como capazes de alterar o limiar olfativo, e nos ?ltimos tempos, a
relev?ncia cl?nica relacionada ?s altera??es nesse limiar tem sido bastante
abordada, principalmente, em rela??o a doen?as neurodegenerativas. Em paralelo,
muitas ind?strias t?m buscado instrumentos inovadores para avaliar o impacto dos
aromas na popula??o. Dada a car?ncia de ferramentas nacionais adequadas para
essas aplica??es, o presente trabalho desenvolveu um sistema para est?mulo
olfativo robusto, instrumentado e automatizado para estudos de neuroimagens, com
uma interface homem-m?quina capaz de controlar e visualizar o funcionamento de
forma amig?vel. Os resultados obtidos demonstraram que o sistema desenvolvido foi
instrumentado de forma compat?vel com o ambiente de Resson?ncia Magn?tica
funcional. Al?m disso, nebulizou a amostra arom?tica de forma homog?nea. Dessa
forma, esse instrumento ser? capaz de auxiliar na identifica??o dos mecanismos
envolvidos na altera??o do limiar olfativo em diferentes situa??es, podendo
proporcionar avan?os cl?nicos importantes; al?m, de poder ser uma ferramenta
auxiliar em estrat?gias de marketing empresarial.
|
1509 |
An?lise do tipo de substrato na fabrica??o de c?lulas solares bifaciais finasCosta, Graziella Fernandes Nassau 21 January 2015 (has links)
Made available in DSpace on 2015-04-14T13:56:35Z (GMT). No. of bitstreams: 1
465042.pdf: 1247743 bytes, checksum: b3674abb15c6f86607716451b781b2ce (MD5)
Previous issue date: 2015-01-21 / The thin bifacial solar cells are a promising opportunity to reduce costs in manufacturing solar cells. These devices take advantage of solar radiation more efficiently by using the both sides of the solar cell to produce electricity. This study aimed to analyze the type of substrate, n and p, for the manufacture of thin bifacial solar cells with silicon substrate Czochralski (Cz-Si) with a thickness of 130 μm. The wafers, provided by the company Meyer Burger, were obtained by wire cutting process. The evaluation of the influence of texture processing time on the wafer, the diffusion/firing temperature optimization of metallic pastes deposited by screen printing and finally the comparison of the electrical parameters of solar cells with those from thin bifacial manufactured devices obtained by etching were performed. From a standard process of NT-Solar texture etch, two immersion times were tested, 50 min and 60 min, and the former showed the lowest weighted average reflectance and devices with higher short circuit density. The diffusion/firing of Ag and Al metallic pastes have been optimized considering the thermal processing temperature in the range between 850 ? C and 890 ? C. It was observed that the highest average efficiency were between 860 ? C and 870 ? C. The best performance were observed in the cells fabricated with phosphorous emitter in front and boron rear side, i.e., the structure n+np+ and n+pp+, and the efficiencies in front side was 12.8% and 13.6%, respectively and in the rear side 10.4 % and 9.0 %, respectively. By comparing these results with solar cells obtained by similar processes using chemical thinned wafers, the n+np+ structure had 1 % lower efficiency and the n+pp+ one presented similar efficiency values. Regarding the type of substrate, it can be concluded that the solar cells fabricated with the n-type substrate showed higher bifaciality, but the most efficient was manufactured with p-type silicon / As c?lulas solares bifaciais finas representam uma oportunidade promissora para reduzir os custos na fabrica??o de c?lulas solares ao aproveitar a radia??o solar de maneira mais eficiente utilizando as duas faces do dispositivo para produzir energia el?trica. Este trabalho teve como objetivo a an?lise do tipo de base, n e p, para fabrica??o de c?lulas solares bifaciais finas com substrato de sil?cio Czochralski (Si- Cz) com espessura da ordem de 130 μm obtidas ap?s processo de corte a fios e fornecidas pela empresa Meyer Burguer. Foi realizada a avalia??o da influ?ncia do tempo de processo de textura??o, a otimiza??o da temperatura de queima/difus?o das pastas met?licas depositadas por serigrafia e, por fim, a compara??o dos par?metros el?tricos das c?lulas solares com os obtidos em dispositivos bifaciais fabricados em l?minas finas obtidas por ataque qu?mico. A partir de um processo de textura??o padr?o do NT-Solar dois tempos de imers?o foram testados, 50 min e 60 min, sendo que o primeiro produziu a menor reflet?ncia m?dia ponderada e os dispositivos com maior densidade de corrente de curto-circuito. A queima das pastas met?licas de Ag e Al foi otimizada considerando a temperatura do processo t?rmico no intervalo entre 850 ?C e 890 ?C. Observou-se que a maior efici?ncia m?dia se encontra entre 860 ?C e 870 ?C. As c?lulas solares mais eficientes foram as fabricadas com a regi?o frontal dopada com f?sforo e a posterior dopada com boro, isto ?, as estruturas n+np+ e n+pp+ com efici?ncias frontal de 12,8 % e 13,6 %, respectivamente, e efici?ncia posterior de 10,4 % e 9,0 %, respectivamente. Ao comparar estes resultados com c?lulas solares obtidas por processos similares e fabricadas com l?minas de outros fabricantes a estrutura n+np+ apresentou efici?ncia 1 % menor e a estrutura n+pp+ apresentou valores similares. Quanto ao tipo de substrato, as c?lulas solares fabricadas com o tipo n apresentaram melhor bifacialidade, mas as mais eficientes foram as fabricadas com sil?cio tipo p.
|
1510 |
Monitoramento do fluxo de controle de processadores embarcados baseado em profiling de softwareRocha, Cl?udia Antunes 28 February 2007 (has links)
Made available in DSpace on 2015-04-14T13:56:35Z (GMT). No. of bitstreams: 1
389987.pdf: 1360851 bytes, checksum: d8bf43ca52fd146b24970288170182a3 (MD5)
Previous issue date: 2007-02-28 / Nos ?ltimos anos, observa-se com grande euforia o crescimento do mercado de sistemas embarcados nas ?reas econ?mico-sociais de grande import?ncia, tais como a sa?de, telecomunica??es, automotiva e aeroespacial, entre outras. Como conseq??ncia, exige-se maior robustez tanto do hardware quanto do software integrante destes sistemas, al?m de componentes de baixo custo, principalmente mem?ria. Dentre os tipos poss?veis de falhas, as falhas que alteram o fluxo de controle de processadores que executam aplica??es embarcadas, por implicarem em quase sempre em falhas catastr?ficas do sistema, s?o focadas nesta disserta??o. Por falhas catastr?ficas, entende-se como sendo aquelas falhas que al?m de induzir o sistema a produzir um comportamento diferente daquele esperado para a sua fun??o, implicam na maioria das vezes tamb?m na reinicializa??o do sistema como forma de recupera??o da falha. Assim, a utiliza??o de t?cnicas capazes de detectar estes tipos de falhas evita que as mesmas se propaguem pelo sistema e acabem gerando sa?das incorretas, pois tais falhas podem ser catastr?ficas para a seguran?a dos usu?rios e para a imagem e reputa??o das empresas. Por?m, a utiliza??o de t?cnicas de detec??o de falhas gera um aumento na taxa de ocupa??o de mem?ria do sistema, bem como provoca aumento da degrada??o de desempenho, o que pode ser considerado um fator cr?tico tratando-se de aplica??es embarcadas de tempo-real. Como alternativa para minimizar estes fatores, tr?s hip?teses foram investigadas, sendo uma delas implementada. Assim, nesta disserta??o prop?e-se uma abordagem baseada em software profiling que analisa o grafo de fluxo de controle da aplica??o, visando ? otimiza??o do n?mero de assinaturas (checkpoints) a serem inseridas no c?digo-fonte. Para validar a abordagem proposta, foi realizada por simula??o a inje??o de tr?s tipos de falhas: jump, nop e bit-flip, sobre diferentes programas aplicativos. Este processo de inje??o de falhas foi acelerado via prototipagem do sistema em hardware, atrav?s do uso de um FPGA (Field-Programmable Gate Array) em uma placa comercial da Xilinx. A an?lise dos resultados obtidos indica que a t?cnica proposta reduz o n?mero de assinaturas inseridas no c?digo da aplica??o, e portanto, minimizando o overhead de mem?ria e a degrada??o do desempenho do sistema, ao passo que mant?m aproximadamente inalterado n?vel de cobertura de falhas quando comparada a outras t?cnicas atualmente existentes na literatura
|
Page generated in 0.0382 seconds