Spelling suggestions: "subject:"aux résiduelles"" "subject:"aux résidus""
1 |
Degradation of estrogenic endocrine disruptors by laccases: from estrogenicity monitoring methods to reactor designBlavier, Julie 28 December 2015 (has links)
In the past decades, much concern has been expressed regarding organic micropollutants generating endocrine disruption. In particular, estrogenic endocrine disruptors, compounds that interfere with the estrogenic hormonal mechanisms, are in the center of environmental scien- tists attention. Numerous endocrine disrupting effects have been observed at concentrations corresponding to those found in aquatic environments, such as feminization of fauna, infertility, reproductive disturbance, cancer, or developmental disruption. Wastewater treatment plants ef- fluents have been identified as the main source of estrogenic endocrine disruptors in the aquatic environment, due to inappropriate treatment. Promising alternative treatment systems based on the use of ligninolytic enzymes (e.g. laccases) have recently emerged. This work falls within the framework of these new techniques. Althoughno environmentally safe threshold can clearly be set, focusing on the removal of global estrogenicity in water instead of concentrations of targeted estrogenic compounds seems a relevant research. To our knowledge, the use of these recently emerged enzymatic processes at an industrial scale (such as for the treatment of urban wastewater), oriented towards water overall estrogenicity, has not been implemented yet.The general objective of this work was to develop ans study a process of removal of estro- genicity by laccases from white-rot fungi, in laboratory, with the purpose of design and scale-up for industrial implementation. This work consisted of the conception, characterization, testing, study and modeling of this process.First, in order to enable the study and the scaling-up of a process of estrogenicity removal, op- timizing the technologies of quantification of estrogenicity in water was a real necessity. Therefore, a study of the methods of estrogenicity monitoring, within a treatment process framework, was conducted. Based on a wide literature review, existing methods were gathered and assessed with the aim of their use as monitoring and design tools. Fromthat review, four methods were selected and tested according to numerous criteria and their compatibility with our process: three bioassays (Yeast Estrogen Screen assay; Lyticase-assisted Yeast Estrogen Screen assay; MCF-7 cell based reporter gene assay) and one analytical method (High Performance Liquid Chromatography with UV detection, HPLC-UV). Concentration-response curves towards the reference 17β-estradiol, in several solvents, were acquired. A fitting model was developed for further expression of all measurements in Estradiol Equivalents. The methods were used to evaluate the estrogenicity of bisphenol A, triclosan and nonylphenol, along with estrogenicity of mixtures of bisphenol A and 17β-estradiol. The testing of these four methods enabled the assessment of their sensitivity, re- producibility, and implementation. Based on that experimental assessment, the Lyticase-assisted Yeast Estrogen Screen (LYES) assay was selected and systematized to be further applied, in combination with an adapted protocol of HPLC-UV analysis, to the monitoring of estrogenicity removal in two lab-scaled reactors. The LYES assay demonstrated a real methodological potential for thescale-up of an estrogenicity removal process and could be used as a design tool. For both reactors, results have indicated that HPLC-UV and LYES assay methods are completely inter- changeable in the case of bisphenol A monitoring (in the conditions used in this work). This work also highlighted the peculiar behavior of mixtures of bisphenol A and 17β-estradiol in terms of estrogenicity, and the parallel observation of an enhancement of bisphenol A estrogenicity removalin presence of 17β-estradiol.In the second part of this work, a batch reactor with laccases in solubilized form was developed and estrogenicity removal was assessed. Kinetics data for the degradation of estrogenic endocrinedisruptors were acquired with the LYES assay (estrogenicity) and the HPLC-UV method (concen- trations). Degradations were performed from several solutions of bisphenol A, 17β-estradiol, and mixtures. In the case of 17β-estradiol and mixtures, conversions reached minimum 90% within 1 hour of degradation at our conditions, with no dependency on pollutant initial concentrations. In the case of bisphenol A, conversions varied from 0 to 100% after 6 hours of degradation and were shown tobe strongly dependent on BPA initial concentrations, indicating the laccases deac- tivation by substrate. Bisphenol A byproducts of degradation were also analyzed, which indicated their absence of estrogenicity and their potential linear evolution with BPA degradation. Acquired kinetics data were exploited for the modeling of the batch degradations kinetics. At this stage of the work, no clear kinetics conclusions could be made in this part.From an industrial point of view, the use of immobilized enzymes is more cost-effective, due to the improvement of enzymes recovery and stability. Therefore, in the third part of this work, a continuous column-shaped packed-bed reactor composed of laccases immobilized on a silica support was developed. The packed-bed reactor was built and tested in laboratory. Residence time distributions, pressure drop calculations, and tracer degradations were performed on the re- actor for its characterization.Immobilization and activity measurements protocols were applied. Similar monitoring than in the batch reactor (LYES assay and HPLC-UV) were performed during continuous degradations of bisphenol A, 17β-estradiol, and mixtures in the packed-bed reactor. Acquired kinetics data were exploited to study and model the kinetics occurring in the packed-bed reactor. Mass transfer phenomena and laccases deactivation by substrate in the reactors were investigated and modeled, revealing, depending on the pollutant, the presence of slight external mass transfer limitation and the strong dependence of the kinetics on laccases deactivation. A design tool, in the form of a mathematical model for the design of a packed-bed reactor with immobilized laccases for the degradation of bisphenol A and related estrogenicity, was developed. The model was validated (simple validation) on experimental data. The model was then used, as a comparison, for the design of a reactor with similar conditions than a documented technique of bisphenol A degradation by ozone. The design resulted in a reactor twice smaller than for degradation by ozone, for the same conversion.In the current context of environmental crisis, this work proposed a first version of a promising practical solution for the treatment of environmentally problematic e-EDCs, oriented towards water overall estrogenicity monitoring and removal, and using natural biocatalysts. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
|
2 |
Estimation de traitabilité potentielle d'eaux résiduaires industrielles par de nouveaux paramètres de caractérisationMuret-Marty, Carole 07 December 2001 (has links) (PDF)
L'évolution de la réglementation, avec notamment l'obligation de la maîtrise des rejets aqueux pousse les industriels à m~ttre en place des filières de traitement et 1 ou de valorisation. L'objectif de ce travail est de proposer une méthodologie simple et rapide de caractérisation d'effluents industriels contenant de la "D.C.O. dure", afin d'évaluer leur traitabilité potentielle vis-à-vis de certains traitements. Pour cela, une nouvelle démarche de caractérisation des effluents a été élaborée, principalement basée sur une méthode alternative : la spectrophotométrie UV et complétée par des tests de dégradation par irradiation UV. L'exploitation des spectres UV et de leur dérivée seconde d'E.R.I. provenant de différentes industrie (pharmacie, pétrochimie ... ) a permis de définir deux nouveaux paramètres : le Facteur de Structuration (SF) qui permet l'identification de la structuration des spectres UV et l'Indice de Phototraitabilité (Ip), associé à la valeur de la dilution nécessaire à l'acquisition du spectre UV sans saturation, prédit le potentiel photodégradable d'un effluent. Ip permet en outre de prédire le caractère biodégradable d'un effluent, étroitement lié à son caractère photodégradable. Cette démarche de caractérisation a été complétée par d'autres tests de traitabilité : ainsi, un nouveau coefficient de partage octanol-eau ("Kowuv") dont le suivi est réalisé par spectrophotométrie UV, permet d'évaluer le caractère adsorbable d'un effluent, tandis que la différence .obtenue entre les spectres UV d'un effluent brut, et d'un effluent filtré permet d'identifier la présence ou non de MES. Les résultats acquis au cours de cette étude ont permis l'élaboration d'un prototype d'outil d'aide à la décision (LOFT-ERI) pour un choix simple et rapide d'orientation vers une filière de traitement la plus adaptée.
|
3 |
Biodegradation of slowly biodegradable organic matter in wastewater treatment plant (WWTP) : In depth analysis of physical and biological factors affecting hydrolysis of large particles / Biodégradation de la matière organique lentement biodégradable dans les stations d'épuration : analyse des facteurs physiques et biologiques affectant l'hydrolyse des particules de grande tailleBenneouala, Mourad 04 May 2017 (has links)
Dans cette thèse, la biodégradation et le devenir des matières organiques lentement biodégradables contenues dans les eaux usées ont été étudiés. La thèse s’est particulièrement penchée sur l’étude du processus d’hydrolyse dans la mesure où plusieurs auteurs considèrent qu’il s’agit du processus limitant durant la dégradation des matières considérées. L’analyse des résultats de la littérature en complétés de ceux que nous avons obtenu en laboratoire a permis d’identifier et ainsi souligner les manques par rapport aux mécanismes qui régissent la dégradation des matières organiques lentement biodégradables. Ensuite, nous avons confronté ces résultats expérimentaux (expériences réalisées en batch sur des substrats type « particules décantables ») aux modèles conventionnels du traitement des eaux mais aussi à d’autres modèles moins usuels afin d’évaluer les performances de ces derniers à décrire l’hydrolyse des différents substrats. La difficulté de ces modèles à décrire la diversité des situations rencontrées nous a amené à développer un nouveau modèle qui tient compte des propriétés physiques et géométriques du substrat et qui permettrait d’améliorer la caractérisation du processus d’hydrolyse. Enfin, nous nous sommes intéressés à la distinction d’une biomasse hydrolytique dans la masse cellulaire totale et de déterminer son origine. Il a été clairement démontré que l’hydrolyse des PSS dans les procédés à boues activées était plus impactée par les bactéries indigènes, initialement adsorbées dans le réseau, que par les bactéries exogènes, en provenance d’un inoculum de boue activées. / In this work, the fate and biodegradation of slowly biodegradable organic matter contained in wastewaters were investigated. The hydrolysis process was particularly targeted as many sources proved that it controls the fate of the considered substrate. First, a synopsis of the literature results related to this topic as well as internal results were investigated especially in terms of respirometric aspects (OUR measurement) in order to identify differences and/or similarities between the experiments and, thus, address gaps in knowledge of the mechanisms that are involved in the hydrolysis of this matter. Then, in the second part of this thesis, experimental data from batch respirometric tests (performed in our laboratory), involving typical slowly biodegradable matter that are found in wastewaters (e.g. Particulate settleable solids, toilet paper…), were confronted to conventional (IAWQ models) and non-conventional models to evaluate the efficiencies of those models to describe the hydrolysis step. In the third part of this thesis, based on hypotheses, a novel conceptual framework was developed in order to enhance the description of the hydrolysis process. The physical properties (density, size, shape) of the components (bacteria and substrate) were taken into account in this model. Finally, in the fourth and last chapter of this thesis, the specific role of each bacterial population involved in the biodegradation of slowly biodegradable organic matter was assessed. It was here clearly evidenced that the hydrolysis of PSS in activated sludge processes appears more influenced by the initially adsorbed bacteria onto the sewage than by the added AS-inoculum concentration.
|
4 |
Présence, devenir et traitement des biocides dans les rejets d'un établissement hospitalier / Occurence, fate and treatment of biocides from a University Hospital wastewater networkLasek, Florence 11 December 2018 (has links)
L’objectif de ce travail a été d’étudier la présence, le devenir et le traitement de biocides dans les rejets d’un établissement hospitalier. Pour cela, 3 substances biocides, représentatives d’une activité de soins (i.e. didécylmethylammonium (DDAC), digluconate de chlorhexidine (CHD) et bis(aminopropryl)laurylamine (BAPLA)) ont été ciblées et 5 campagnes de prélèvements réalisées sur l’ensemble du réseau de collecte des eaux usées du CHU de Poitiers ont été menées. Dans ces conditions, une émission continue de biocides sur 24 h, avec des quantités rejetées en journée plus importantes du fait de la plus forte activité de soins et de nettoyage durant cette période a été montrée. Des concentrations de l’ordre de quelques mg/L pour le DDAC et de quelques dizaines de µg/L pour le CHD et le BAPLA ont été observées. En termes de flux massiques, la comparaison des quantités retrouvées dans les rejets aux quantités utilisées par le CHU a permis de préciser la nature des sources d’émission ainsi que les usages et/ou les pratiques les plus propices à ces rejets.Parallèlement, une étude laboratoire de la stabilité et du devenir des biocides dans les eaux résiduaires a été menée. Une première estimation des quantités adsorbées sur les matières en suspension a été obtenue. De même, les produits de dégradation susceptibles d’être générés lors du rejet de biocides en présence d’un résiduel de chlore ont été identifiés et l’évolution de l’écotoxicité vis-à-vis de Vibrio fisheri a été évaluée.Enfin, la possibilité d’un traitement à la source utilisant l’ozone pour limiter les rejets de biocides a été envisagée et une étude pilote sur le terrain a été menée. / The objectives of this study was to study the presence, the fate and the treatment of some biocides in the wastewaters from a hospital. 3 biocidal substances specific to healthcare activities (i.e. didecylmethylammonium chloride (DDAC), chlorhexidine digluconate (CHD) and bis(aminopropryl)laurylamine (BAPLA)) were selected and 5 sampling campaigns were conducted throughout the entire Poitiers University Hospital sewage system. Under these conditions, a continuous biocide discharges over 24 h was shown, with higher quantities discharged during the day. This was pointing out the greater healthcare and facility cleaning activities taking place during this period. Concentrations of a few mg/L for DDAC and a few dozens of µg/L for CHD and BAPLA were detected. In terms of mass flows, the comparison of the quantities found in the discharges with the quantities used by the university hospital made it possible to specify the nature of the sources of emission as well as the uses and / or the practices most favorable to these discharges.In parallel, a laboratory study of the stability and fate of biocides in wastewater was conducted. A first estimate of the amounts adsorbed on suspended solids was obtained. Similarly, the degradation products likely to be generated during the release of biocides in the presence of a chlorine residual have been identified and the evolution of the ecotoxicity towards Vibrio fisheri has been evaluated.Finally, the proposal of an ozone based treatment at source was carried out to limit biocide discharges and a pilot study was conducted on the hospital wastewaters.
|
5 |
Relations entre la variabilité de la pollution des eaux usées urbaines et les contextes géographiques, socio-économiques et culturels au Bénin et en France / Relationship between the variability of urban wastewater pollution and the geographical, socio-economic and cultural contexts in Benin and FranceAtinkpahoun, Nelly Chrystelle Houéfa 27 June 2018 (has links)
Le non traitement et/ou le traitement inadéquat des eaux usées constitue l’une des causes principales de la pollution des ressources en eau. Pour y remédier il importe de mettre en place des infrastructures d’assainissement fonctionnelles et d’optimiser leur performance. Améliorer les stratégies de contrôle est l’action principale de cette optimisation, et la modélisation en est l’un des défis à relever. Pour ce faire, les présents travaux visent à fournir des connaissances spécifiques sur la variabilité des eaux usées urbaines de Cotonou et du Grand-Nancy et de disposer de données expérimentales qui serviront à court ou moyen termes au développement de modèle de génération d’eaux usées virtuelles. Les travaux ont consisté à échantillonner pendant plusieurs mois des eaux usées urbaines de temps sec en entrée de STEP (quartier vie-nouvelle à Cotonou et commune de Maxéville dans le Grand-Nancy) à travers des prélèvements horaires sur 24 h. A Cotonou, des prélèvements ont été aussi faits dans les collecteurs. In-situ ont été prises les mesures du débit. Au laboratoire sont faites sur les échantillons des analyses spécifiques de dosage des polluants. Une simulation des variabilités des eaux usées est également faite au moyen de modèle de génération des eaux usées virtuelles. Des travaux, il ressort les constats ci-après : - les débits en entrée de STEP (Grand-Nancy) présentent une variabilité journalière avec trois pics respectivement vers 10 h, 14 h et 21 h les jours ouvrés et caractérisée pendant les jours de week-end par une diminution de 2% (les samedis) et 9% (les dimanches) avec un retard de 2 h dans l’apparition du premier pic de la journée ; - les eaux usées de Cotonou présentent une plus forte pollution par rapport aux eaux usées urbaines du Grand-Nancy bien que l’Equivalent Habitant raccordé à La STEP de Cotonou (≈ 1 200 EH) soit de loin plus faible que celui du Grand-Nancy (≈ 275 000 EH) ; - néanmoins on note une plus forte conductivité électrique des eaux usées du Grand-Nancy ainsi qu’un excès en Europium plus élevé comparativement à ceux des eaux usées de Cotonou ; - la variabilité journalière pour l’ensemble des paramètres dans les bassins est très prononcée, exception faite pour le pH qui présente une similarité dans les deux contextes géographiques ; - le modèle de génération des eaux usées virtuelle en développement intègre bien le mode de vie du bassin de collecte du Grand-Nancy et a montré des simulations des variations du débit et de la pollution similaires aux variations expérimentales réelles ; - les recherches et le développement du modèle se poursuivent pour étendre ce dernier aux métaux lourds et l’appliquer aux bassins de collecte. Le modèle permet de combler des lacunes de données, de donner des fréquences plus élevées à la dynamique des données, de créer divers scénarii de perturbation de variabilité des eaux usées en situation virtuelle et de faire des prédictions de situations réelles pour une amélioration des performances des STEP / Untreated and / or inadequate treatment of wastewater is one of the main causes of water resource pollution. To remedy this it is important to establish functional sanitation infrastructure and optimize their performance. Improving control strategies is the main action of this optimization, and modeling is one of the challenges. To do this, the present work aims to provide specific knowledge on the variability of urban wastewater of Cotonou and Grand Nancy and to have experimental data to be used for short or medium term for the development of a generation model of virtual wastewater. The work consisted in sampling for several months the urban wastewater at the entrance of STEP (« Vie-Nouvelle » city in Cotonou and Maxéville in Grand-Nancy) through hourly samples over 24 hours. In Cotonou, samples were also taken from the collectors. In-situ were taken measurements of the flow. In the laboratory are made on samples specific analyses of pollutant dosing. Simulation of wastewater variability is also done using a virtual wastewater generation model. From the works, the following observations emerge: - flows from STEP (Grand-Nancy) show daily variability with three peaks respectively at around 10 am, 2 pm and 9 pm on weekdays and characterized on weekend days by a 2% decrease (Saturdays) and 9% (Sundays) with a delay of 2 hours in the appearance of the first peak of the day ; - Wastewater of Cotonou exhibit greater pollution than urban wastewater of Grand-Nancy although Population Equivalent connected to the STEP of Cotonou (≈ 1,200 PE) is far lower than that of Grand-Nancy (≈ 275,000 PE) ; - Nevertheless, there is a higher electrical conductivity of wastewater from Greater Nancy and a higher excess of Europium compared to that of Cotonou wastewater ; - The daily variability for all the parameters in the catchments is very pronounced, except for the pH which has a similarity in the two geographical contexts ; - the virtual wastewater generation model is well integrated with the lifestyle of the Grand-Nancy catchment basin and showed simulations of flow and pollution variations similar to actual experimental variations ; - research and model development is continuing to extend the model to heavy metals and apply it to collection basins ; The model allows to bridge data gaps, giving higher frequencies to dynamic data, create various wastewater variability distubance scenarios in virtual situation and make real situations predictions for improved performance of WWTP
|
6 |
Vertical-flow constructed wetlands for the treatment of wastewater and stormwater from combined sewer systems / Traitement des eaux résiduaires de temps sec et temps de pluie en réseau unitaire par filtres plantés de roseauxArias Lopez, José Luis 30 September 2013 (has links)
Les filtres plantés de roseaux à écoulement vertical (FPR-V) pour le traitement des eaux usées domestiques sont relativement bien développés en France et permettent de réaliser un traitement poussé de la matière carbonée et la nitrification. La robustesse de cette filière réside également dans sa capacité à accepter des surcharges hydrauliques en temps de pluie. Cependant ces limites d’acceptation hydraulique ne sont pas bien définies et demandent à être optimisées. La conception des FPR-V pour accepter des surcharges hydrauliques est un travail complexe car le contexte local affecte fortement les débits d’eau entrants dans la station lors d’un événement pluvieux. Dans de tels cas, la conception de filtres demande l’utilisation de modèles dynamiques. Ces modèles s’appuient le plus souvent sur une approche mécanistique et sont à l'origine conçus et utilisés pour la recherche. Cependant, si ces modèles sont des outils puissants pour décrire en détail la dynamique du FPR-V, ils sont généralement trop complexes à manipuler pour des utilisateurs non experts. Choisir entre une description détaillée et une manipulation facile dépendra des objectifs de modélisation. Quand des objectifs de dimensionnement global sont visés par les concepteurs, l'utilisation de modèles simplifiés semble une bonne alternative. Les modèles simplifiés sont faciles à utiliser pour la conception de FPR-V mais ils sont peu nombreux. Cependant ils sont adaptés à des configurations spécifiques liées au traitement des surverses de déversoirs d’orage, ce qui n’est pas le cas pour les FPR-V traitant des eaux usées domestiques. En effet, pour ce type de FPR-V les vitesses d’infiltration du système varient considérablement. En conséquence, ce travail de thèse a pour objectif de développer un modèle hydraulique simplifié des FPR-V qui permettra de guider les concepteurs dans le processus d’adaptation des FPR-V pour traiter les eaux usées domestiques des périodes de temps sec et de temps de pluie. Le modèle simplifié permet de relier (i) l’hydraulique du filtre, en simulant le temps de noyage à la surface, et (ii) les performances biologiques, en établissant des «alertes de dysfonctionnement », basées sur l'évaluation des performances épuratoires et sur les variations des formes azotées à la sortie du filtre mesurées en continu. Les «alertes de dysfonctionnement» représentent la charge hydraulique maximale qu'un filtre peut accepter sans compromettre son activité biologique. Le modèle simplifié a été utilisé pour la modélisation hydraulique du FPR-V à long terme (i) pour analyser l’impact du contexte local et la conception du filtre dans l’acceptation de surcharges hydrauliques. Grâce à cet analyse, (ii) on peut proposer les dimensionnements de FPR-V qui arrivent à mieux gérer l’acceptation des surcharges hydrauliques. / French vertical-flow constructed wetlands (VFCW) directly treating raw wastewater are known to perform well on for SS, COD and nitrification. They are also known to robustly cope with hydraulic overloads during rainfall events. Although numerous systems have been installed in areas equipped with a combined sewer, the limits of stormwater acceptance remain ill-defined and need to be improved. Looking at the various VFCW designs and usages reported in the literature, it is difficult to draw any consensus on their hydraulic limits. Consequently, designing VFCW to accept hydraulic overloads is a complex task, as local context strongly impacts inlet flows produced during rainfall events. Dynamic models appear a requisite for filter design in such cases. Numerical CW models have essentially focused on horizontal flow, with few attempting to study VFCW dynamics which are more commonly tackled via mechanistic models. Although mechanistic models are powerful tools for describing processes within the VFCW, they are generally too complicated to be readily used by designers. The choice between detailed description and easy handling will depend on the modelling aims. If the aim is a global design tool, simplified models offer a good alternative. However, the simplified models geared to studying VFCW dynamics are extremely reduced. They are easy-handling for design and well-adapted to specific purposes (combined sewer overflow -CSO- treatment) but not necessarily to VFCW treating combined sewer wastewater, where long-term infiltration rates vary significantly. Consequently, this PhD thesis work focused on developing a simplified hydraulic model of VFCW to guide designers through the process of adapting VFCW systems to treat domestic wastewater in both dry and rain events. The simplified model makes it possible to link (i) hydraulics, by simulation of ponding time variations, (ii) biological performances, by establishing “dysfunction alerts” based on treatment performance assessment and variations in online N forms effluent from the young VFCW. These “dysfunction alerts” plot the maximal hydraulic load that a filter can accept without compromising its biological activity. The simplified model was used to model long-term hydraulics in the VFCW (i) to analyze the impact of local context and filter design on hydraulic overload acceptance (using “dysfunction alerts” and bypass discharges) and (ii) to propose VFCW designs for accepting hydraulic overload in different contexts. The modelling demonstrates that VFCW can limit days with bypass discharges to less than 20 times per year without jeopardizing filter performances. Moreover, the most problematic scenario on stormwater treatment remains a watershed with high imperviousness coefficient and low slope under a Bretagne-type climate, demonstrating that the filter is more sensitive to periodicity and duration than to intensity of rainfall events.
|
7 |
Dégradation du paracétamol et de la ciprofloxacine par des procédés d'oxydation avancés dans des eaux usées / Degradation of paracetamol and ciprofloxacin by advanced oxidation processes in wastewater.González-Labrada, Katia 20 December 2018 (has links)
Ce travail étudie la faisabilité de différents procédés d’oxydation avancée (POAs) pour le traitement d’eaux usées industrielles. Le secteur visé est l’industrie pharmaceutique, les essais ont été menés sur des eaux synthétiques contenant deux molécules modèles: le paracétamol et la ciprofloxacine. Les procédés étudiés dans ce travail sont l’ozonation, la sonochimie, le traitement par radiation gamma et la dégradation par radiation ultraviolet. Ces techniques sont envisagées en mono-traitement ou en combinaison avec des oxydants et/ou des catalyseurs (peroxyde d’hydrogène, réactif de Fenton et zéolite Fe/MFI). Pour chaque procédé, l'influence de différents paramètres opératoires est analysée et interprétée dans l'objectif de déterminer les meilleures conditions pour la conversion et la minéralisation du chaque polluant. Parmi les paramètres étudiés se trouvent le pH, la concentration en oxydant, la concentration du catalyseur, la dose de la radiation gamma, la fréquence et la puissance ultrasonore. Des effets synergiques importants sont trouvés pour l’ozonation catalytique et pour le photo-Fenton par rapport aux procédés seuls. D’un point de vue purement énergétique, les traitements les plus efficaces sont l’oxydation radio- Fenton et l’oxydation photo-Fenton. Sur la base de ces résultats, un photo-réacteur solaire à recirculation est mis en oeuvre pour traiter par oxydation photo-Fenton des solutions synthétiques préparées avec un mélange de paracétamol et de ciprofloxacine dans l’eau du robinet mais aussi avec des eaux usées réelles dopées avec les deux composés. Dans les deux cas, la dégradation des molécules dépasse 95% dans les 15 premières minutes et la minéralisation dépasse 55% en 180 minutes. / In this work, the feasibility of paracetamol and ciprofloxacin degradation by different advanced oxidation processes (AOPs) was investigated. These molecules are representative of pharmaceutical pollutants found in wastewater. The used processes were the ozonation, the high frequency ultrasound, the gamma radiation and the ultraviolet radiation, alone or in combination with oxidizers and/or catalysts (hydrogen peroxide, Fenton’s reagent and zeolite Fe/MFI). The influence of different operations parameters (pH, oxidant concentration, catalyst concentration, gamma radiation dose and ultrasonic power and frequency) for each processes were studied, in order to determine the optimal operating ranges for the degradation and mineralization of the pharmaceuticals pollutants. Results showed marked synergistic effects by combining individual processes with hydrogen peroxide or Fenton’s reagent, being the most important synergy factors those corresponding to the heterogeneous catalytic ozonation and photo-Fenton processes. Taking into account the energy consumption, the mineralization and the synergy factor, the most effective treatments were radio-Fenton oxidation and photo-Fenton oxidation. Optimal conditions for photo-Fenton oxidation were studied in an open channel reactor at bench scale in tap water and in a real matrix from a municipal wastewater treatment plant. Samples were spiked with a mixture of the pharmaceuticals. In both cases 95% degradation within the first 15 minutes was achieved and its mineralization exceeded 55% in three hours.
|
Page generated in 0.0545 seconds