Spelling suggestions: "subject:"alectric impedance"" "subject:"alectric lmpedance""
11 |
Data acquisition and analysis for reopneumographic study.January 1993 (has links)
by Leung Chung-chu. / Thesis (M.Phil.)--Chinese University of Hong Kong, 1993. / Includes bibliographical references (leaves 101-107). / ABSTRACT --- p.i / ACKNOWLEDGEMENTS --- p.iii / LIST OF ABBREVIATIONS --- p.iv / LIST OF PUBLICATIONS --- p.v / TABLE OF CONTENTS --- p.vi / Chapter CHAPTER 1 --- Introduction / Chapter 1.1 --- Background of the Rheopneumograph --- p.1 / Chapter 1.2 --- The Electrical Bio-impedance (EBI) technique used in Rheopneumography --- p.2 / Chapter 1.3 --- Problems with analysis of Rheopneumograph --- p.6 / Chapter 1.4 --- The EBI measurement unit --- p.8 / Chapter 1.5 --- Data analysis in Rheopneumography and the electrode design --- p.8 / Chapter 1.6 --- Modelling analysis in Rheopneumography --- p.9 / Chapter 1.7 --- Thesis outline --- p.10 / Chapter CHAPTER 2 --- Improvement to the impedance measurement system / Chapter 2.1 --- Introduction --- p.13 / Chapter 2.1.1 --- The Coherent Detection method in EBI signal --- p.13 / Chapter 2.1.2 --- To discuss the problem in Coherent Detection method --- p.16 / Chapter 2.1.3 --- To discuss the problem in Costas Receiver method --- p.16 / Chapter 2.2 --- The concept of the Amplitude Modulation Receiver --- p.17 / Chapter 2.3 --- EBI measurement unit design using AM receiver technique --- p.18 / Chapter 2.3.1 --- The C-Y receiver --- p.18 / Chapter 2.3.2 --- A simple DC offset adjust circuit --- p.23 / Chapter 2.3.3 --- 555KHz local oscillator and constant current source --- p.25 / Chapter 2.3.4 --- Selection of the low pass filter --- p.29 / Chapter 2.4 --- The characteristic of the whole circuit and performance --- p.32 / Chapter 2.5 --- Discussion --- p.36 / Chapter CHAPTER 3 --- Data analysis in Rheopneumogram / Chapter 3.1 --- Introduction --- p.38 / Chapter 3.2 --- The 5-10 electrode array method applied in Thorax Montage --- p.39 / Chapter 3.2.1 --- The definition of the 5-10 electrode array method --- p.39 / Chapter 3.2.2 --- The advantage of the 5-10 electrode array method --- p.41 / Chapter 3.3 --- Signal analysis in subject-to-subject comparison --- p.41 / Chapter 3.3.1 --- The relationship between the ECG and Rheopneumogram --- p.45 / Chapter 3.4 --- Identification of the best electrode location in Rheopneumograph using Pump-jet model --- p.51 / Chapter 3.4.1 --- The fluid mechanical model device (Pump-jet model) --- p.51 / Chapter 3.4.2 --- Result and discussion --- p.57 / Chapter 3.5 --- Electrical conductivity studies in Silicon fluid-Graphite composites applied in EBI electrode array system --- p.62 / Chapter 3.5.1 --- Experimental procedure and results --- p.63 / Chapter 3.6 --- Discussion --- p.73 / Chapter CHAPTER 4 --- Model analysis for the Impedance Rheopneumogram / Chapter 4.1 --- Introduction --- p.76 / Chapter 4.2 --- Blood flow phenomenon study in Rheopneumogram using Pipeline model --- p.78 / Chapter 4.2.1 --- Model derivation --- p.79 / Chapter 4.2.2 --- Result and discussion --- p.86 / Chapter 4.3 --- Blood velocity study in Rheopneumogram using Pump-jet model --- p.94 / Chapter 4.3.1 --- Result and discussion --- p.94 / Chapter 4.4 --- Conclusion --- p.96 / Chapter CHAPTER 5 --- General discussion and Conclusion --- p.97 / Chapter CHAPTER 6 --- Reference --- p.101 / APPENDICES / Chapter I --- Measurement method in the study --- p.107 / Chapter II --- The simplification of an equation in pump-jet model --- p.109 / Chapter III --- The simplification of an equation in pipeline model --- p.111 / Chapter IV --- Impedance relation between body and electrode --- p.112 / Chapter V --- The procedure of the curve fitting --- p.113
|
12 |
Skin sensitivity testing : a biophysical approach /Nyrén, Miruna, January 2002 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2002. / Härtill 5 uppsatser.
|
13 |
Biophysical studies of pigment transport in frog melanophores : impedance measurements and advanced microscopy analyses /Immerstrand, Charlotte January 2003 (has links) (PDF)
Diss. (sammanfattning) Linköping : Univ., 2003. / Härtill 4 uppsatser.
|
14 |
Avaliação de alternativas ao usi de níquel e cromatos no processo de fosfatização tricatiônico aplicado ao aço carbono / Evaluation of alternatives to nickel and chromate in the tricationic phosphating process of carbon steelYAMAGUTI, ROSELE C. de L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:16Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
15 |
Avaliacao do efeito de tratamentos superficiais na resistencia a corrosao de magnetos de Nd-Fe-B / Assessment of the effect of surface treatments on the corrosion resistance of Nd-Fe-B MagnetsMARTINS, EMERSON A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:32Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:42Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
16 |
Estudos numéricos para o problema da tomografia por impedância elétrica / Numerical studies for the problem of electric impedance tomographyJuan Carlos Zavaleta Aguilar 11 March 2009 (has links)
Este trabalho estuda a técnica de reconstrução de imagens conhecido como tomografia por impedância elétrica em um domínio bidimensional. Esta técnica consiste na alocação de eletrodos na fronteira do volume e uma fonte injeta padrões de corrente através dos eletrodos e medem-se as voltagens resultantes na fronteira. Com estes dados estima-se a condutividade (ou resistividade) do interior do domínio criando-se uma imagem do mesmo. A tomografia por impedância elétrica é um problema inverso e mal posto no sentido de Hadamard. Estudam-se diversos métodos de solução para resolver o problema direto usando métodos numéricos como diferenças finitas e volumes finitos. Proporemos os métodos numéricos a serem aplicados na solução do problema direto os quais serão testados com problemas onde a solução analítica é conhecida. Posteriormente aplicaremos os métodos propostos ao problema especifico. Uma questão importante na reconstrução de imagens é propor a maneira como aproximar o Jacobiano (ou matriz de sensibilidade) do problema, assim desenvolvemos uma técnica para a aproximação do mesmo usando os dados fornecidos pelo problema direto. / In this work is studied the technique of reconstruction of images known as electrical impedance tomography for a two-dimensional domain. This technique consists in the allocation of electrodes on the border of the volume and a source injects patterns of current through the electrodes and then measuring voltages through the other electrodes. With these data it is estimated the conductivity (or resistivity) on the interior of the domain and an image is create of it. The electrical impedance tomography is an inverse and ill conditioned problem in the Hadamard sense. In this work, is studying some numerical methods to solve the direct problem and are applied numerical methods such as the finite difference method and the finite volume method. It is proposed some numerical methods to solve the direct problem which will be tested with analytical problems where the solution is known. Later, apply the methods proposed to the specific issue. An important issue in the reconstruction problems is about the Jacobian (or sensitivity matrix) aproximation, thus proposing a technique for the calculation of even using the data provided by the direct problem. Keywords:
|
17 |
Composição e proporções corporais de meninas com a forma classica de deficiencia da 21-hidroxilase / Body composition and proportions in females with classical 21-hydroxylase deficiencyGonçalves, Ezequiel Moreira, 1977- 20 February 2008 (has links)
Orientador: Gil Guerra Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-10T14:57:15Z (GMT). No. of bitstreams: 1
Goncalves_EzequielMoreira_M.pdf: 3646841 bytes, checksum: 92edeb1af3250e23a5dd5ef4630bd584 (MD5)
Previous issue date: 2008 / Resumo: A Hiperplasia Adrenal Congênita na forma clássica da deficiência da 21-hidroxilase (HAC-C-D21OH) caracteriza-se pela deficiência na síntese do cortisol e, em alguns casos, na aldosterona, e pelo excesso de andrógenos. O objetivo do estudo foi avaliar a composição e as proporções corporais de pacientes do sexo feminino com HAC-C-D21OH e comparar em relação ao controle, à forma clínica da doença e a um grupo controle de ambos os sexos. A casuística foi composta por 28 pacientes (grupo casos) do sexo feminino com HAC-C-D21OH divididas de acordo com o controle hormonal (bem e mal controladas) e com a forma da doença (virilizante simples e perdedores de sal). O grupo controle foi composto por 112 indivíduos saudáveis de ambos os sexos, divididos em dois grupos, de acordo com o gênero. Para verificar os efeitos da puberdade nas medidas avaliadas, os três grupos foram subdivididos em três faixas etárias: até 10 anos, de 11 a 14 anos e acima de 15 anos. Para a avaliação das proporções e composição corporais foram utilizadas medidas antropométricas e a impedância bioelétrica. Os dados das medidas antropométricas foram convertidos em escores de desvio padrão (z). Em relação à forma clínica da doença, as virilizantes simples apresentaram valores significativamente maiores de z do IMC, do perímetro da cintura e da área gorda do braço, e no percentual de massa gorda. Em relação ao controle laboratorial, as mal controladas apresentaram z do comprimento da perna significativamente menor. Os casos apresentaram valores significativamente maiores que os controles no z do IMC, área muscular e gorda do braço, perímetro braquial, da cintura e do quadril, do diâmetro biilíaco e no percentual de massa gorda, e menores no z do comprimento da perna e da mão e nos percentuais de água e massa magra. Pode-se notar que as alterações na composição corporal foram observadas em todas as faixas etárias, mas foram se intensificando com a idade, com o predomínio do aumento da massa gorda enquanto as alterações nas proporções corporais se tornaram mais evidentes após a puberdade, com comprometimento principal das extremidades (perna, mão e pé). As variáveis que melhor se ajustaram para diferenciar os grupos caso e controles foram o percentual de gordura, o comprimento da mão e o perímetro do quadril (94,7%). Esse grupo de pacientes apresentou diferenças nas proporções e principalmente na composição corporal, justificando uma avaliação antropométrica ampla e cuidadosa no monitoramento das pacientes com HAC-C-D21OH / Abstract: Congenital Adrenal Hyperplasia due to classical 21-hydroxylase deficiency (CAH-C-21OHD) is characterized by deficiency in the synthesis of cortisol, and, in some cases, also of aldosterone and by excess of androgens. The aim at of the study was to evaluate the body composition and body proportion of women with CAH-C-21OHD in relation to the control and the clinical form of the disease and to a group control of both sexes. The casuistic was composed by twenty-eight patient (cases group) female with CAH-C-21OHD were divided according to control (good or bad) and the clinical form of the disease (salt-wasting and simple-virilizing). The control group was composed by 112 healthy individuals of both sexes, divided in 2 groups, in agreement with the gender. To verify the effects of the puberty in the appraised measures, the 3 groups were subdivided in 3 age groups: up to 10 years, from 11 to 14 years and above 15 years. To evaluate body proportions and composition, anthropometric measurements and electric impedance were analyzed. The data of anthropometric measurements were converted in standard deviation scores (z). In relation to clinical form of the disease, the simple-virilizing presented values significantly larger of z of BMI, of the perimeter of the waist and of the fat area of the arm, and in the percentage of fat mass. In relation to disease control, the patients with bad control showed significantly lower leg length. The cases showed significantly higher values in relation to controls in z of BMI, arm muscle and fat area, brachial perimeter, of the waist and of the hip, of the biiliac diameter and in the fat percentage and smaller in z of the length of the leg and of the hand and in the percentages of water and lean mass. Alterations in the body composition were observed in all of the age groups, but they were if intensifying with the age, with the prevalence of the increase of the fat mass while the alterations in the body proportions if they turned more evident after the puberty, with main compromising of the extremities (leg, hand and foot). The more adjusted variables to explain the differences between cases and controls were percentage of fat mass, hand length and hip perimeter, comprising 94.7% of the differences between the groups. This group of patients showed differences in body proportions, but mainly in body composition, justifying a broad and careful anthropometric evaluation in the monitoring of CAH-C-21OHD patients / Mestrado / Saude da Criança e do Adolescente / Mestre em Saude da Criança e do Adolescente
|
18 |
Avaliação de alternativas ao usi de níquel e cromatos no processo de fosfatização tricatiônico aplicado ao aço carbono / Evaluation of alternatives to nickel and chromate in the tricationic phosphating process of carbon steelYAMAGUTI, ROSELE C. de L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:16Z (GMT). No. of bitstreams: 0 / Camadas de fosfato tricatiônico são largamente utilizadas na indústria automotiva como proteção contra corrosão e adesão de revestimentos orgânicos ao substrato de aço. A combinação do fosfato e revestimento proporciona à superfície metálica, alta durabilidade à corrosão. Porém a camada cristalina obtida com este tipo de fosfato apresenta poros entre os cristais, expondo o substrato metálico ao ambiente corrosivo, tornando importante um tratamento de passivação após fosfatização. O tratamento comercial de fosfatização tricatiônico e subsequente passivação envolvem o uso de elementos tóxicos, tais como níquel e cromo hexavalente, produzindo resíduos que são prejudiciais ao ambiente e seu uso têm sido cada vez mais proibido. O objetivo do presente estudo é investigar o efeito da troca do níquel, no processo de fosfatização, pelo composto de nióbio (oxalato de nióbio e amônio) com relação à resistência à corrosão do aço fosfatizado. Esta investigação foi realizada através de métodos eletroquímicos, utilizando-se principalmente ensaios de polarização potenciodinâmica e técnicas de espectroscopia de impedância eletroquímica (EIE); como também ensaios de névoa salina. Para caracterização superficial das camadas de fosfato foram adotadas, entre outras, as análises por microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva (EDS) e difração de raios-X. Foram adotados dois tipos de banho de fosfato tricatiônico. Inicialmente utilizou-se uma composição de banho preparada em laboratório baseada em formulação usada por indústria de eletrodomésticos. Posteriormente foi adotado um banho com composição típica da indústria automotiva, especialmente preparado para estudos sem a presença do níquel. Os resultados dos testes eletroquímicos mostraram que a camada de fosfato obtida em solução contendo nióbio (zinco, manganês e nióbio) produziu melhor proteção contra corrosão do substrato, comparativamente àquela obtida em banho contendo níquel (zinco, manganês e níquel). O ensaio de névoa salina, por outro lado, sugeriu um desempenho similar com relação à corrosão para estes dois tipos de camadas de fosfato. O oxalato de nióbio e amônio parece apresentar um efeito de passivação mesmo quando usado em banhos de fosfatização. Mas como agente de passivação para aço carbono fosfatizado, os resultados apontaram para a necessidade de se realizar novas pesquisas. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
19 |
Avaliacao do efeito de tratamentos superficiais na resistencia a corrosao de magnetos de Nd-Fe-B / Assessment of the effect of surface treatments on the corrosion resistance of Nd-Fe-B MagnetsMARTINS, EMERSON A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:32Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:42Z (GMT). No. of bitstreams: 0 / Magnetos de Nd-Fe-B produzidos por metalurgia do pó são altamente susceptíveis à corrosão devido à porosidade intrínseca e à sua microestrutura complexa. Por outro lado, tais ímãs apresentam excelentes propriedades magnéticas tendo por isso várias aplicações. Na área nuclear, os ímãs permanentes à base de terras raras-metais de transição-boro (Nd-Fe-B) são utilizados na fabricação de suportes magnéticos (levitação magnética) para ultra-centrífugas utilizadas no enriquecimento isotópico do urânio natural de utilização em reatores nucleares. Em Odontologia são utilizados para fixar próteses totais e parciais sobre implantes, em Ortodontia, para corrigir maloclusões e fazer movimentações dentárias e em Cirurgia buco-maxilo-facial para fixar próteses de grandes defeitos da face. Em equipamentos eletrônicos, os magnetos são utilizados em balanças, cadeados, motores elétricos e principalmente na confecção de discos rígidos de computadores.Diante disso, o objetivo deste trabalho foi avaliar o comportamento de corrosão do magneto e testar tratamentos superficiais a fim de substituir principalmente os tratamentos com cromato que hoje em dia não estão sendo mais utilizados principalmente devido à sua toxicidade e altos custos dos tratamentos dos resíduos. A avaliação da resistência à corrosão foi feita através da análise de curvas de polarização potenciodinâmica, espectroscopia de impedância eletroquímica, medidas de potencial de corrosão versus tempo e microscopia eletrônica de varredura a fim de associar a microestrutura ao comportamento de corrosão apresentado pelas amostras. Os resultados obtidos mostram que estes magnetos são altamente susceptíveis à corrosão e esta ocorre preferencialmente na fase rica em Nd, localizada nos contornos da fase matriz e magnética (). Tratamentos para proteção da superfície com revestimento de silano, revestimento de conversão de cério, moléculas auto-organizáveis (SAM), Cr hexavalente, fosfato tricatiônico seguido por passivação em solução de trióxido de cromo, e revestimento de fosfato obtido por imersão por 24 h em solução de NaH2PO4 (pH= 3,8) seguido de imersão em solução de sulfato de zinco não melhoraram a resistência à corrosão do magneto. Dentre os tratamentos utilizados, o de fosfatização por 24h em solução de NaH2PO4 (pH= 3,8) foi muito superior, conferindo maior proteção contra corrosão quando comparado com os outros tipos de tratamentos testados. ABSTRACT Nd-Fe-B magnets produced by powder metallurgy are highly susceptible to corrosion due to their complex microstructure and intrinsic porosity due to their fabrication process. Moreover, these magnets have excellent magnetic properties and find many applications. In the nuclear area, permanent magnets based on rare earth transition-iron-boron (Ne-Fe-B) are used in the manufacture of magnetic media (magnetic levitation) for ultra-centrifuges used for isotopic enrichment of uranium employed in nuclear reactors. In dentistry these types of magnets are used to fix total and partial prostheses on implants; in orthodontics to correct dental malocclusion and make moves; in buco-maxillo-facial surgery for setting facial prostheses of large defects of the face. In electronic equipment, they are used in scales, locks, electric motors and particularly in the manufacturing of hard drives of computers. The objective of this study is to evaluate the corrosion resistance of the magnet tested and surface treatments that could replace chromating that generates toxic residues and present high cost of processing waste with treatments that are environmentally friendly. The evaluation / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
20 |
Confiabilidade das determinaÃÃes de localizadores eletrÃnicos foraminais: estudos ex vivo e in vivo / Determination of the reliability of electronic foramen locators: ex vivo and in vivo studiesBruno Carvalho de Vasconcelos 23 September 2011 (has links)
nÃo hà / Os localizadores eletrÃnicos foraminais (LEFs) disponÃveis atualmente utilizam diversos mÃtodos de determinaÃÃo eletrÃnica da posiÃÃo foraminal, qual seja a medida entre o forame apical e uma referÃncia incisal/oclusal, definindo consequentemente o comprimento do canal radicular. Cada um desses mÃtodos procura oferecer maior precisÃo e menor sensibilidade a possÃveis interferÃncias no sistema de canais radiculares. Desta forma, procurou-se avaliar a precisÃo de alguns destes LEFs ex vivo e in vivo na realizaÃÃo de odontometrias eletrÃnicas em diferentes posiÃÃes (0,0 mm e -1,0 mm) e em condiÃÃes de uso clÃnico, respectivamente. No estudo ex vivo, 42 prÃ-molares inferiores tiveram seus comprimentos reais comparados a odontometrias eletrÃnicas realizadas com os LEFs Root ZX, Mini Apex Locator, Propex II, iPex e RomiApex A-15. Inicialmente, em funÃÃo dos displays dos aparelhos, determinaram-se mediÃÃes 1,0 mm aquÃm do forame apical (FA), e posteriormente as mediÃÃes no FA. Para o estudo in vivo, dez pacientes que apresentavam prÃ-molares com indicaÃÃo de exodontia como parte de seus planejamentos clÃnicos ortodÃnticos tiveram odontometrias eletrÃnicas realizadas com os LEFs Propex II e Root ZX previamente a exodontia. Os Ãltimos instrumentos utilizados foram fixados aos dentes que foram entÃo extraÃdos e tiveram 4,0 mm apicais de suas raÃzes expostos e analisados quanto à distÃncia entre as pontas dos instrumentos e os FA. No estudo ex vivo, considerando as mediÃÃes realizadas por cada um dos aparelhos a 0,0 mm e a -1,0 mm, a precisÃo dos LEFs foi: 70,6% e 47,1% (Root ZX), 61,8% e 52,9% (Mini Apex Locator), e 67,6% e 38,2% (Propex II), 61,8% e 38,2% (iPex), e 73,5% e 38,2% (RomiApex A-15), respectivamente (Â0,5 mm). DiferenÃas estatÃsticas foram encontradas para o Propex II, iPex e RomiApex A-15, quando comparadas suas leituras nas duas posiÃÃes (0,0mm X -1,0 mm). NÃo foram encontradas diferenÃas entre os LEFs a 0,0 mm, porÃm, a -1,0 mm o iPex foi estatisticamente inferior aos demais. Jà no estudo in vivo, o FA foi localizado em 75% (Root ZX) e 66,7% (Propex II), considerando margem de Â0,5 mm, tendo sido encontrada diferenÃa estatisticamente significante entre os LEFs. Diante do exposto, nas condiÃÃes do estudo, pode-se concluir que os LEFs sÃo ferramentas confiÃveis na determinaÃÃo de comprimentos reais, todavia, nÃo sÃo infalÃveis; que em condiÃÃes ex vivo, quando mantidos aquÃm do FA, todos os LEFs reduziram sua precisÃo, tendo o Propex II, iPex e RomiApex A-15 apresentado diferenÃas significantes; e que em condiÃÃes de uso clÃnico, o Root ZX apresentou maior confiabilidade do que o Propex II. / The electronic foramen locators (EFLs) currently available are based on different methods for determination of the distance between the apical foramen and a coronal reference, consequently presenting the real root canal length. Each of these methods aim to offer greater precision while presenting lower sensitivity to potential interferences found in the root canal system. With this in mind, the goal of this work was to evaluate the precision of some of these EFLs ex vivo and in vivo for electronic measurement of the root canal length at two different positions (0.0 mm and -1.0 mm) and under clinical conditions, respectively. In the ex vivo study, 42 mandibular bicuspids had their actual lengths compared to electronic measurements performed by the following EFLs: Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15. Initial measurements were performed to positions identified by the devices as 1.0 mm short of the apical foramen (AF), and subsequent measurements were at the AF (0.0 mm). For the in vivo study, ten patients with bicuspids referred for extraction as part of their orthodontic clinical planning had electronic root length measurements using two EFLs, Propex II and Root ZX, prior to extraction. The last files used were fixated to the teeth, which were then extracted. Then, the apical 4 mm of the canals were exposed to allow assessment of the distance between the tip of the file and the AF. The percentages of precision from the ex vivo electronic measurements at 0.0 mm and -1.0 mm considering each device were: 70.6% and 47.1% (Root ZX); 61.8% and 52.9% (Mini Apex Locator); 67.6% and 38.2% (Propex II); 61.8% and 38.2% (iPex); and 73.5% and 38.2% (RomiApex A-15), respectively (Â0.5 mm). Statistical differences were observed for Propex II, iPex, and RomiApex A-15 when measurements at both positions were compared (0.0 mm X -1.0 mm). No significant differences between the EFLs were observed at 0. 0 mm. However, at -1.0 mm, the precision of iPex was statistically lower compared with the other devices. Regarding the in vivo study, the AF was located in 75% (Root ZX) and 66.7% of the teeth (Propex II), under a tolerance margin of Â0.5 mm. Statistically significant differences were observed between the two EFLs. Based on the results obtained and considering the conditions of this work, it was concluded that EFLs are reliable tools for determining the real length of the canal, but are not infallible. It was also observed in the ex vivo experiments that all EFLs had decreased precision in measurements with the instruments short of the AF, with significant differences observed between Propex II, iPex, and RomiApex A-15. Moreover, it was concluded that under clinical conditions, Root ZX was more reliable than Propex II.
|
Page generated in 0.062 seconds