• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 3
  • Tagged with
  • 7
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ion insertion into electrode materials studied with X-ray and electron spectroscopic methods /

Henningsson, Anders, January 1900 (has links)
Diss. (sammanfattning) Uppsala : Univ., 2002. / Härtill 11 uppsatser.
2

Automatisk test för myoelektroder. / Automatic testequipment for myoelectrodes.

Widén, Jonas January 2003 (has links)
<p>Denna rapport avhandlar en tio veckors period på Otto Bock Scandinavia AB i Norrköping. Där analyserades en manuell testutrusning för funktionstest av myoelektroder, för att mäta muskelspänningar. Myoelektroderna används till att styra gripfunktionen hos handproteser, för patienter som förlorat en del av sin arm. Analysen ska resultera i att ge ett förslag på en automatiserad test av elektroderna. En stor del av rapporten består av studier kring hur testmetoderna fungerar och elektrodernas användning och funktion. Slutligen behandlas även ett förslag på en automatiserad test för elektroderna. </p> / <p>The present report concerns a ten weeks period at Otto Bock Scandinavia AB in Norrköping. An analyse of a manual test equipment for testing myoelectrodes, who is used to measure muscle potential in the arm. The myoelectrodes are used to control a grip function on hand prostheses, which is used by persons who has lost their lower arm. The analyse should result in a proposal of an automation of the manual test equipment for the electrodes. </p><p>A significant part of the report discusses the function of test methods and who the electrodes are used for and their function. Finally, discusses a proposal on an automated test for the electrodes.</p>
3

Automatisk test för myoelektroder. / Automatic testequipment for myoelectrodes.

Widén, Jonas January 2003 (has links)
Denna rapport avhandlar en tio veckors period på Otto Bock Scandinavia AB i Norrköping. Där analyserades en manuell testutrusning för funktionstest av myoelektroder, för att mäta muskelspänningar. Myoelektroderna används till att styra gripfunktionen hos handproteser, för patienter som förlorat en del av sin arm. Analysen ska resultera i att ge ett förslag på en automatiserad test av elektroderna. En stor del av rapporten består av studier kring hur testmetoderna fungerar och elektrodernas användning och funktion. Slutligen behandlas även ett förslag på en automatiserad test för elektroderna. / The present report concerns a ten weeks period at Otto Bock Scandinavia AB in Norrköping. An analyse of a manual test equipment for testing myoelectrodes, who is used to measure muscle potential in the arm. The myoelectrodes are used to control a grip function on hand prostheses, which is used by persons who has lost their lower arm. The analyse should result in a proposal of an automation of the manual test equipment for the electrodes. A significant part of the report discusses the function of test methods and who the electrodes are used for and their function. Finally, discusses a proposal on an automated test for the electrodes.
4

Characterisation of Manufacturing Defects in Anode, Cathode, and Separator of Lithium-ion Batteries

Vadakkemuriyil Prasannen, Prathibha January 2023 (has links)
This study characterizes production-line defects in lithium-ion batteries' anode, cathode, and separators. Lithium-ion batteries demand has increased tremendously in the last decades due to their use in various applications, including electric vehicles, portable electronics, and energy storage systems. Therefore, characterizing defects in these batteries is crucial to understand their performance and reliability. This study uses scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) analysis to identify and analyze defects in the battery components. The major critical defects encountered in the study are impurities, contaminations, agglomerates, point defects, line defects, and more. This study helps improve the quality and reliability of lithium-ion batteries by providing guidelines to analyze and address essential deficiencies during the manufacturing process. / Denna studie karakteriserar produktionslinjedefekter i litiumjonbatteriers anod, katod och separatorer. Efterfrågan på litiumjonbatterier har ökat enormt under de senaste decennierna på grund av deras användning i olika applikationer, inklusive elfordon, bärbar elektronik och energilagringssystem. Därför är det avgörande att karakterisera defekter i dessa batterier för att förstå deras prestanda och tillförlitlighet. Denna studie använder svepelektronmikroskopi (SEM) och energidispersiv röntgenspektroskopi (EDS) analys för att identifiera och analysera defekter i batterikomponenterna. De största kritiska defekterna som påträffats i studien är föroreningar, föroreningar, agglomerat, punktdefekter, linjedefekter med mera. Denna studie hjälper till att förbättra kvaliteten och tillförlitligheten hos litiumjonbatterier genom att tillhandahålla riktlinjer för att analysera och åtgärda väsentliga brister under tillverkningsprocessen
5

EEG metodikens påverkan på sensitivitet och specificitet : En litteraturstudie / The impact of the EEG methodology on sensitivity and specificity

Chibani, Sonya January 2021 (has links)
Elektroencefalografi (EEG) är en viktig metod för att upptäcka specifika avvikelser från homeostatiskt tillstånd. Sensitivitet och specificitet är av stor betydelse vid bedömning av den diagnostiska tillförlitligheten hos EEG metoden. Syftet med studien var att ge en övergripande översikt kring faktorer som påverkar sensitivitet och specificitet vid tre typfall med olika karaktär på EEG mönstret. De tre typfallen är sömndeprivering (låg aktivitet), epilepsi (hög aktivitet) och hjärtstopp (metabolisk aktivitet). Metoden som användes i studien var baserad på vetenskapliga artiklar som uppsöktes via databaserna Medline och PubMed. Inklusionskriterierna omfattade artiklar på engelska samt publicerad år 2010–2020. Sensitiviteten och specificiteten spelar stor roll vid prognosbedömningen efter ett hjärtstopp då patienten kan drabbas av ischemi och hjärnvävnaden skadas. Det finns flera olika metoder som genomförs vid EEG undersökningen. Dessa metoder är ambulatoriskt EEG, kontinuerlig EEG, Video EEG samt mobila EEG. Det gjordes en jämförelse mellan sensitiviteten och specificiteten för att se hur dessa påverkas och förändras vid de olika typfallen. Den viktiga slutsatsen var att metodiken spelade också en roll över hur sensitiviteten och specificiteten påverkades. / Electroencephalography (EEG) is an important method for detecting specific deviations from homeostatic status. Sensitivity and specificity are of great importance in assessing the diagnostic reliability of the EEG method. The purpose of the study was to provide an overall overview of the factors that affect sensitivity and specificity in three typical cases with different character of the EEG pattern. The three typical cases are sleep deprivation (low activity), epilepsy (high activity) and cardiac arrest (metabolic activity). The method used in the study was based on scientific articles that were searched via databases Medline and PubMed. The inclusion criteria included articles in English and published in 2010–2020. Sensitivity and specificity play a major role in the prognosis assessment after a cardiac arrest as the patient may suffer from ischemia and the brain tissue is damaged. There are several different methods used in the EEG survey. These methods are ambulatory EEG, continuous EEG, Video EEG and mobile EEG. A comparison was made between the sensitivity and the specificity to see how these are affected and changed in the different typical cases. The important conclusion was that the methodology also played a role in how the sensitivity and specificity were affected.
6

Thermal Physical Properties of Söderberg Electrode Material

Rigas, Konstantinos January 2019 (has links)
Söderberg electrodes take part in the production of ferroalloys, copper, nickel, platinum, and calcium carbide. They are involved in a continuous and with low costs operation. The study of such electrodes is essential, since research and new findings will provide us with vital information regarding the operation of such furnaces leading to a more efficient production. Therefore, the study of Söderberg electrodes materials characteristics is of great importance. The current work refers to the thermal properties of Söderberg electrode paste by focusing on the thermal conductivity coefficient from room temperature up to 800 °C with the Transient Plane Source (TPS) method applied to an electrode paste material with softening point at 65°C. Another electrode paste with higher softening point at 90 °C and an already baked material are studied to some extent. The study gives significant results for the thermal conductivity coefficient for all the investigated cases. Results indicate variation of coefficients regarding the phase evolved during heating at different temperatures. In principle, thermal conductivity of the green paste with low softening point decreases until 400°C and increases after the baking point which is found in between 400-500°C. A few measurements for the green paste with higher softening point indicate the same trend. For the case of the fully baked electrode, thermal conductivity seems to keep an increasing trend according to temperature increase. On the two last mentioned materials, more experimental work will be conducted in future. / Söderberg-elektroder används till produktionen av ferrolegeringar, koppar, nickel, platina och kalciumkarbider. De är involverade i kontinuerliga och lågkostnadsoperationer. Studien av sådana elektroder är väsentlig eftersom forskning och nya fynd kommer att ge oss viktig information om driften av sådana ugnar vilket leder till en effektivare produktion. Därför är studien av Söderberg-elektrodens materialegenskaper av stor betydelse. Det nuvarande arbetet refererar till de termiska egenskaperna hos Söderberg-elektrodpastan genom att fokusera på den termiska konduktivitetskoefficienten från rumstemperatur upp till 800°C med den TPS-metoden (Transient Plane Source) tillämpad på ett elektrodpasta-material med en mjukningspunkt vid 65°C. En annan elektrodpasta med en högre mjukningspunkt vid 90°C samt ett redan bakat material studeras även till viss del. Studien ger signifikanta resultat för värmeledningsförmågan för alla undersökta fall. Resultaten indikerar på variationer av koefficienterna gällande fasen som utvecklas under uppvärmning vid olika temperaturer. I stort sett minskar värmeledningsförmågan hos den gröna pastan med låg mjukningspunkt upp till 400°C och ökar efter bakningspunkten som finns mellan 400-500°C. Några mätningar för den gröna pastan med en högre mjukningspunkt visar samma trend. När det gäller den helt bakade elektroden verkar värmdeledningsförmågan hålla en ökande trend beroende på temeperaturökningen. På de två sistnämnda materialen kommer mer experimentellt arbete att genomföras i framtiden.
7

Characterization of diazepam binding inhibitor as a structure-function tool for human ɣ-aminobutyric acid-A receptors

Simon-Guth, Szabolcs January 2023 (has links)
Gammaaminosmörsyrareceptorer typ A (GABAAR) är pentameriska ligandstyrda kloridkanaler som uppvisar neurohämmande egenskaper. Därmed är de primära läkemedelsmål för flera ångestdämpande och lugnande läkemedel som används för att minska förekomsten av aktionspotential i neuroner. Trots vikten av dessa receptorer har strukturen av öppen receptor för GABAAR inte lösts hittills, på grund av deras snabba desensibiliseringskinetik. Diazepambindande hämmare (DBI) är en neuropeptid som tidigare rapporterats vara en positiv modulerare för α5β3 GABAAR. I denna studie framställdes DBI genom rekombinant proteinexpression, och den positiva moduleringen undersöktes och karakteriserades med hjälp av voltage-clamp med två elektroder på Xenopus laevis oocyter. För att kunna studera DBI moduleringen skapades GABA dos-responskurvan, och dess karakteristik undersöktes. Baserat på resultaten verkar den positiva moduleringen av DBI vara koncentrationsberoende. Vidare orsakar moduleringen en 2,16-faldig ökning av GABA-framkallad ström vid dess maximala modulationskoncentration. Trots att ström signaler från voltage-clamp uppvisar en viss grad av variabilitet stämmer resultaten överens med tidigare rapporterade observationer som utredde DBI moduleringen respektive GABA dos-responskurvan för α5β3 GABAAR. Dessa resultat kan utnyttjas för att stödja framtida strukturella studier av GABAAR genom att använda denna kunskap om DBI för att potentiellt kunna stabilisera den öppna receptorn, såväl som för att förstå mekanismen för interaktionen mellan DBI och GABAAR. / γ-Aminobutyric acid type-A receptors (GABAARs) are pentameric ligand-gated chloride channels which exhibit neuro inhibitory effects. Hence, they are the primary drug-targets of multiple anxiolytic and sedative drugs used to inhibit the firing rate of neurons. Despite the importance of these receptors, the open structure of GABAAR has not been resolved, owing to their rapid desensitization kinetics. Diazepam binding inhibitor (DBI) is a neuropeptide previously reported to positively modulate the α5β3 GABAARs. In this study, DBI was recombinantly expressed, and this positive modulation was further investigated and characterized by using two-electrode voltage clamp of Xenopus oocytes. For the purpose of studying DBI modulation, GABA dose-response curve was generated, and its characteristics were assessed. Based on the results, the positive modulation of DBI appears to be concentration dependent. Furthermore, the modulation causes a 2.16-fold increase in GABA-elicited current at its maximum modulatory concentration. Although the current traces present some degree of variability, the results are supported by being consistent with previously reported findings investigating DBI modulation and the dose-response curve for α5β3 GABAARs, respectively. These findings can be used to support future structural studies of GABAARs by utilizing this knowledge of DBI to potentially stabilize the open structure of the receptor, as well as in understanding the mechanism of interaction between DBI and GABAARs.

Page generated in 0.0543 seconds