• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 29
  • Tagged with
  • 29
  • 29
  • 29
  • 29
  • 29
  • 18
  • 17
  • 16
  • 16
  • 16
  • 16
  • 16
  • 12
  • 11
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Determinação e degradação eletroquímica do estrogênio natural estrona usando anodos de diamante dopado com boro / Electrochemical determination and degradation of the natural estrogen estrone using boron-doped diamond anodes

Brocenschi, Ricardo Francisco 06 December 2013 (has links)
Made available in DSpace on 2016-06-02T20:34:49Z (GMT). No. of bitstreams: 1 5699.pdf: 4598797 bytes, checksum: 3d3bdd7719250cba1af6bbb0169b7216 (MD5) Previous issue date: 2013-12-06 / Universidade Federal de Sao Carlos / Different electrochemical techniques were used to characterize the boron-doped diamond (BDD) electrode and to determine estrone. After parameters optimization, the detection limits obtained using differential pulse voltammetry (0.27 μmol L 1) and square-wave voltammetry (0.096 μmol L 1) with a cathodically pretreated BDD electrode were comparable to values reported in the literature. An even smaller value was obtained when amperometric detection was used with a flow injection system FIA-EC (0.050 μmol L 1), because there is a reduction of capacitive current interferences when a fixed potential is applied, as the continuous flow rate (surface cleaning and mass transport effect). In all cases, the BDD electrode presented a stable response (inter- and intra-day repeatabilities) and different matrices did not have significant influence on the detection of estrone. Consequently, the investigated techniques are promising for this purpose, with excellent accuracy and precision. In the electrochemical degradation of estrone studies in a flow reactor a rapid decay of estrone concentration was attained, due to the high oxidation power of the BDD electrode. This decay is dependent on the studied parameters (current density, flow rate, and pH); best results were attained at pH 3. Intermediate products formed during electrolyses of estrone at different pH (3, 7, and 10) were investigated by LC-MS/MS; thus, inedited (partial) degradation pathways were proposed, aiming at understanding the influence of pH on the generation of intermediates. Finally, electrochemical degradation of estrone at pH 7 using the BDD electrode was compared with the one attained with a β‒PbO2 electrode, also with an inedited mechanistic study. / Diferentes técnicas eletroquímicas foram usadas para caracterizar o eletrodo de diamante dopado com boro (BDD) e para a determinação de estrona. Após otimização de parâmetros, os valores de limite de detecção obtidos usando a voltametria de pulso diferencial (0,27 μmol L 1) e a voltametria de onda quadrada (0,096 μmol L 1) com o eletrodo de BDD prétratado catodicamente foram comparáveis àqueles na literatura. Um valor ainda menor foi obtido quando se utilizou detecção amperométrica em um sistema de injeção em fluxo FIA-EC (0,050 μmol L 1), dada a redução de interferências da corrente capacitiva pela aplicação de um potencial fixo, fluxo contínuo (transporte de massa e renovação de superfície do eletrodo). Em todos os casos, o eletrodo de BDD apresentou-se bastante estável (repetibilidade intra-dia e entre-dias) e diferentes matrizes não tiveram influências significantes na detecção da estrona. Consequentemente, as técnicas investigadas se mostraram promissoras para esse propósito, com excelentes precisão e exatidão. Na degradação eletroquímica de estrona em um reator em fluxo, devido ao alto poder oxidante do eletrodo de BDD, obteve-se um decaimento rápido da concentração de estrona, dependente das variáveis investigadas (densidade de corrente, vazão volumétrica e pH); melhores resultados foram obtidos a pH 3. Os intermediários formados durante eletrólises de estrona em diferentes pHs (3, 7 e 10) foram investigados por LCMS/ MS, sendo que rotas inéditas de degradação (parcial) foram propostas, no intuito de entender melhor a influência do pH na formação dos intermediários. Além disso, a degradação eletroquímica de estrona utilizando o eletrodo de BDD foi ainda comparada com a obtida com um eletrodo de β‒PbO2, também com estudo mecanístico inédito.
12

Determinação voltamétrica de aspartame e ciclamato de sódio em produtos dietéticos empregando um eletrodo de diamante dopado com boro. / Voltammetric determination of aspartame and sodium Cyclamate in dietary products employing boron doped Diamond electrode.

Medeiros, Roberta Antigo 03 August 2007 (has links)
Made available in DSpace on 2016-06-02T20:36:11Z (GMT). No. of bitstreams: 1 1617.pdf: 729214 bytes, checksum: 10ad5db9f5bca8eca9a3c32793d82e5c (MD5) Previous issue date: 2007-08-03 / Universidade Federal de Sao Carlos / The development of electroanalytical procedures for aspartame and sodium cyclamate determination in dietary products using a boron doped diamond (BDD) electrode and the square wave voltammetry (SWV) is reported in this work. The first procedure development is reported in related to the determination of aspartame in dietary products employing BDD electrode and the SWV technique after optimization of the experimental conditions. The recovery of aspartame from 8 samples ranged from 95.9 % to 104.4 % of the added amount. The analytical curve was linear in the aspartame concentration range from 9.9 x 10-6 mol L-1 to 5.2 x 10-5 mol L-1 with a detection limit of 2.3 x 10-7 mol L-1. The relative standard deviation for 5 successive determinations of 1.0 x 10-4 mol L-1 aspartame was 0.17 % and the relative standard deviation for 5 determinations of aspartame in different days was 2.8 %. The concentration of aspartame determined in several dietary products using the BDD electrode and those concentrations determined using a HPLC method are in close agreement (calculated t-values did not exceed the critical values at the 95 % confidence level) and within an acceptable range of error. In the sequence, the analytical determination of sodium cyclamate was studied by oxidation of this substance on BDD electrode employed the SWV. The analytical curve for sodium cyclamate was linear in the concentration range from 5.0 x 10-5 to 4.1 x 10-4 mol L-1 with a detection limit of 4.8 x 10-6 mol L-1. The relative standard deviation for five successive measurements was 1.1 % and the relative standard deviation for determinations of 3.0 x 10-3 mol L-1 sodium cyclamate in five different days was 2,4 %. The recoveries values from five samples ranged from 98.6 % to 106,0 % and the results found using the proposed method agreed at the 95% confidence level with those from a HPLC method. Finally, a procedure for simultaneous determination of aspartame and sodium cyclamate was developed, once the oxidation peak potentials of the aspartame and sodium cyclamate are 1.6 V and 1.9 V, respectively. The analytical curves were linear in the aspartame concentration range from 5.0 x 10-6 to 4.0 x 10-5 mol L-1, with detection limit of 3.5 x 10-7 mol L-1 and from 5.0 x 10-5 to 4.0 x 10-4 mol L-1, with detection limit of 4.5 x 10 -6 mol L-1 for sodium cyclamate. The simultaneous determination of these sweeteners in various dietary products was implemented with success. / Neste trabalho descreve-se o desenvolvimento de procedimentos eletroanalíticos para a determinação dos edulcorantes aspartame e ciclamato de sódio em produtos dietéticos utilizando um eletrodo de diamante dopado com boro (BDD) e a voltametria de onda quadrada (SWV). No primeiro procedimento desenvolvido determinou-se aspartame em produtos dietéticos empregando-se um eletrodo de BDD e a técnica voltamétrica por onda quadrada após otimização das condições experimentais. A recuperação de aspartame em 8 amostras variou de 95,9 % a 104,4 % dos valores adicionados. A curva analítica foi linear no intervalo de concentração de aspartame de 9,9 x 10-6 mol L-1 a 5,2 x 10-5 mol L-1 com um limite de detecção de 2,3 x 10-7 mol L-1. O desvio padrão relativo de 5 determinações sucessivas de aspartame 1,0 x 10-4 mol L-1 foi de 0,17 % (repetibilidade) e de 5 determinações em dias e soluções diferentes de aspartame foi de 2,8 % (reprodutibilidade). A quantificação de aspartame nos produtos dietéticos utilizando o eletrodo de BDD apresentou resultados concordantes com os resultados obtidos empregando-se o método cromatográfico a um nível de confiança de 95 %. Na seqüência, foi estudada a determinação de ciclamato de sódio por oxidação desta substância sobre o eletrodo de BDD, empregando-se a técnica SWV. A curva analítica para o ciclamato de sódio foi linear no intervalo de concentração de 5,0 x 10-5 e 4,1 x 10-4 mol L-1 com um limite de detecção de 4,8 x 10-6 mol L-1. O desvio padrão relativo de 5 medidas sucessivas de ciclamato de sódio 3,0 x 10-3 mol L-1 foi de 1,1 % (repetibilidade) e de 5 determinações em dias e soluções de ciclamato de sódio diferentes foi de 2,4 % (reprodutibilidade). Os valores do estudo de recuperação em 5 amostras comerciais variaram entre 98,6 % e 106 % e os resultados obtidos na XI determinação do ciclamato de sódio nessas amostras estão em concordância com os resultados obtidos empregando-se o método de referência (HPLC). Finalmente, foi desenvolvido um procedimento para a determinação simultânea de aspartame e ciclamato de sódio, uma vez que estes edulcorantes apresentaram potenciais de pico de oxidação bem distintos, 1,6 V e 1,9 V respectivamente. As curvas analíticas foram lineares no intervalo de concentração de aspartame entre 5,0 x 10-6 e 4,0 x 10-5 mol L-1, com um limite de detecção de 3,5 x 10-7 mol L-1 e de 5,0 x 10-5 a 4,0 x 10-4 mol L-1 com um limite de detecção de 4,5 x 10-6 mol L-1 para o ciclamato de sódio. A determinação simultânea destes edulcorantes em produtos dietéticos também apresentou resultados satisfatórios e concordantes com os resultados obtidos pelo método cromatográfico.
13

Desenvolvimento de métodos eletroanalíticos empregando o eletrodo de diamante dopado com boro para a determinação simultânea de edulcorantes e corantes em produtos alimentícios / Development of electroanalytical methods employing a boron-doped diamond electrode for simultaneous determination of sweeteners and colorants in food samples

Deroco, Patrícia Batista 18 June 2014 (has links)
Made available in DSpace on 2016-06-02T20:36:52Z (GMT). No. of bitstreams: 1 6160.pdf: 2543391 bytes, checksum: afa6ef244ecf2d6cf7d9a7b48f3525a8 (MD5) Previous issue date: 2014-06-18 / Universidade Federal de Minas Gerais / In this work, three electroanalytical proceduces were developed for simultaneous determination of sweeteners (aspartame (AS) and acesulfame-K (AK)) and colorants (sunset yellow (SY), indigo carmine (IC) and allura red (AR)) in food samples using a boron-doped diamond electrode (BDD). AS and SY pair was determined with no need of previous separation in a 0.30 mol L-1 H2SO4 solution with BDD electrode anodically pretreated and using multiple pulses amperometry (MPA) with flow injection analysis system (FIA). The sequence of double-potential waveform with time dependence, previously optimized, was Edea = +1.30 V / 150 ms (pulse potential at which occurs only SY oxidation) and Edet.2 = +1.70 V / 200 ms (pulse potential at which the oxidation of both analytes, AS and SY, occurs). The analytical curves showed linearity from 0.25 a 25.0 ^mol L-1, with detection limit (LD) of 0.04 ^mol L-1 for both analytes. Subsequently, the analytical determination of IC and AR was carried out in a 0.30 mol L-1 H2SO4 solution with BDD electrode cathodically pretreated using FIA-MPA. The dual-potential waveform was the following: Edeu = +0.75 V / 200 ms (pulse potential at which occurs only IC oxidation) and Edet2 = +1.10 V / 50 ms (pulse potential at which the oxidation of both analytes, IC and AR, occurs). The analytical curves were linear from 0.070 to 1.0 ^mol L-1 for IC and 0.040 to 0.77 ^mol L-1 for AR, with LDs of 40 nmol L-1 and 7.0 nmol L-1, respectively. The analytical frequencies for each method were 120 and 153 determinations per hour for AS and SY pair and for IC and AR pair, respectively. Another procedure was developed for determination of AS and AK sweeteners using a BDD electrode anodically pretreated and differential pulse voltammetry in a 0.30 mol L-1 H2SO4 solution. The analytical curves presented linearity from 4.4 to 110 ^mol L-1 for AS and from 0.39 to 7.6 mmol L-1 for AK and LDs obtained for AS and AK were 1.6 ^mol L-1 and 0.28 mmol L-1, respectively. Finally, all these proposed methods were successfully applied in analysis of food samples containing the pairs of (AS and SY or IC and AR or AS and AK). The obtained results were satisfactory and similar to those obtained using comparative HPLC methods at a confidence level of 95%. / Neste trabalho, desenvolveu-se métodos eletroanalíticos para a determinação simultânea dos pares: amarelo crepúsculo (AC) e aspartame (AS), azul indigotina (AI) e vermelho 40 (V40)), bem como aspartame (AS) e acesulfame-K (AK) em produtos alimentícios utilizando-se o eletrodo de diamante dopado com boro (BDD). O par AS e AC foi determinado, sem a necessidade de separação prévia em H2SO4 0,30 mol L-1 com o eletrodo de BDD pré-tratado anodicamente e utilizando amperometria de múltiplos pulsos (MPA) em análise por injeção em fluxo. Uma sequência de aplicação dos pulsos em função do tempo, previamente otimizada, foi de Edeu = +1,30 V / 150 ms (pulso de potencial no qual ocorre a oxidação apenas de AC) e Edet.2 = +1,70 V / 200 ms (pulso de potencial no qual ocorre a oxidação de AS e AC). As curvas analíticas obtidas apresentaram linearidades de 0,25 a 25,0 ^mol L_1 com limite de detecção (LD) de 0,04 ^mol L_1 para ambos os analitos. Na sequência determinou-se AI e V40 em H2SO4 0,30 mol L-1 com o eletrodo de BDD pré-tratado catodicamente empregando FIA-MPA. A sequência de aplicação dos pulsos em função do tempo foi: Edea = +0,75V / 200 ms (pulso de potencial no qual ocorre a oxidação apenas do AI) e Edet.2 = +1,10V / 50 ms (pulso de potencial no qual ocorre a oxidação de ambos os analitos (AI e V40)). As curvas analíticas obtidas apresentaram linearidades de 0,070 a 1,0 ^mol L_1 para o AI e de 0,040 a 0,77 ^mol L_1 para o V40 e os LDs obtidos para AI e V40 foram 40 e 7,0 nmol L_1, respectivamente. As frequências analíticas para cada método foram de 120 e 153 determinações por hora para o par AS e AC e para o par AI e V40, respectivamente. Outro procedimento desenvolvido foi para a determinação dos edulcorantes AS e AK com o eletrodo de BDD pré-tratado anodicamente e a técnica de voltametria de pulso diferencial (DPV) em H2SO4 0,30 mol L-1. As curvas analíticas foram lineares nos intervalos de concentração de 4,4 a 110 ^mol L_1 para o AS e de 0,39 a 7,6 mmol L_1 para o AK e os LDs obtidos para AS e AK foram 1,6^mol L_1 e 0,28 mmol L-1, respectivamente. Finalmente, todos estes métodos desenvolvidos foram empregados na análise de amostras alimentícias comerciais contendo os pares dos analitos (AS e AC ou AI e V40 ou AS e AK). Os resultados obtidos empregando-se os métodos propostos foram concordantes com os resultados obtidos empregando-se métodos comparativos (HPLC) em um nível de confiança de 95%.
14

Desenvolvimento de metodologias voltamétricas para determinação simultânea de carbofurano e metomil usando eletrodo de diamante dopado com boro / Developing voltammetric methodologies for simultaneous determination of carbofuran and methomyl using boron-doped diamond electrodes

Santos, Janete Clair da Silva 22 July 2016 (has links)
Submitted by ANA KARLA PEREIRA RODRIGUES (anakarla_@hotmail.com) on 2017-08-07T13:46:38Z No. of bitstreams: 1 arquivototal.pdf: 2969105 bytes, checksum: 49f5cf66f2a78db52f94fecddc4c5be1 (MD5) / Made available in DSpace on 2017-08-07T13:46:38Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2969105 bytes, checksum: 49f5cf66f2a78db52f94fecddc4c5be1 (MD5) Previous issue date: 2016-07-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Carbofuran (2,2-dimethyl-2,3-dihydro-1-benzofuran-7yl-methylcarbamate) is a kind of pesticide with nematicide and acaricide power, belonging to the chemical group of benzofuranyl methylcarbamate; methomyl {(R, S)-methyl-N- {[(methylamino) carbonyl] oxy} ethanimidothioate} is also a pesticide with acaricide power, it is inserted into the methylcarbamate oxime chemical group. They present high toxicity, and both are inserted in class I of toxicity and class II of environmental risks. In general, their detection and analytical determinations are carried with chromatographic methods, electrophoretic, fluorometric, spectrophotometric fluorescence X-rays and electroanalytical. In this study, one has made use of boron-doped diamond electrode due to its inherent properties: wide potential range and low adsorption of organic molecules. Thus, one has studied the electrochemical behavior of carbofuran and methomyl using cyclic voltammetry, square-wave voltammetry, differential pulse voltammetry, being developed methodologies for simultaneous studies by SWV and DPV. Throughout the pH analysis by SWV technique, one observed oxidation process of carbofuran (Ep1 ≈ + 1.3 V vs. EAg/AgCl) and the same process for the methomyl (Ep1 ≈ + 1.6 V vs. EAg/AgCl) in DDB cathodically polarized. A simultaneous methodology using SWV was developed, being the best analytical conditions: pH 1.0 (sulfuric ac. 0.1 mol L-1), f = 150 s-1, ΔEs = 4 mV, ΔEp = 30 mV, td = 10 s, obtaining a linear range of 2.5 x 10-6 to 7.9 x 10-5 mol L-1. Also, an alternative methodology has been developed with the DPV technique. The best VPD analysis conditions that provided the most sensitive voltammetric response were: pH 1.0 (sulfuric ac. 0.1 mol L-1), TI = 0.2, ΔEs = 4 mV, ΔEp = 50 mV, td = 10s, with a linear range of 2.48 x 10-4 to 1.42 x 10-4 mol L-1. This work shows that the two proposed methodologies are feasible. Keywords: methomyl, carbofuran, boron-doped diamond electrodes, voltammetry. / O carbofurano (metilcarbamato de 2,3-hidro-2,2-dimetilbenzofuran-7ila) é um pesticida com ação nematicida e acaricida pertencente ao grupo químico metilcarbamato de benzofuranila, e o metomil [(R, S)-metil-N-(metilcarbamoiloxi) tiocetimidato] é um inseticida e acaricida inserido no grupo químico metilcarbamato de oxima. Possuem alta toxicidade, tendo ambos: classe toxicológica I e classe ambiental II. Em geral, suas detecções e determinações analítica envolvem métodos cromatográficos, eletroforéticos, fluorimétricos, espectrofotométricos com fluorescência de raios-X e eletroanalíticos. Neste estudo se fez uso de um eletrodo de diamante dopado com boro devido às suas propriedades intrínsecas: ampla janela de potencial e baixa adsorção de moléculas orgânicas. Assim, foi estudado o comportamento eletroquímico de carbofurano e metomil usando voltametria cíclica, voltametria de onda quadrada e voltametria de pulso diferencial, sendo desenvolvido metodologias para estudos simultâneo por VOQ e VPD. Através do estudo de pH, realizado pela técnica VOQ, observou-se a oxidação do carbofurano (Ep1 ≈ + 1,3 V vs. EAg/AgCl) e a oxidação do metomil (Ep1 ≈ + 1,6 V vs. EAg/AgCl) em EDDB catódicamente polarizado. Uma metodologia simultânea empregando VOQ foi desenvolvida, sendo as melhores condições de análise: pH 1,0 (ácido sulfúrico 0,1 mol L-1), f = 150 s-1, ΔEs = 4 mV, ΔEp = 30 mV, td = 10 s, obtendo uma faixa linear de 2,5 x 10-6 a 7,9 x 10-5 mol L-1. Também foi desenvolvida uma metodologia alternativa com a técnica de VPD. As melhores condições de análise da VPD que proporcionaram a resposta voltamétrica mais sensível foram: pH 1,0 (ácido sulfúrico 0,1 mol L-1), IT = 0,2 s, ΔEs = 4 mV, ΔEp = 50 mV, td = 10 s, apresentando uma faixa linear 2,48 x 10-4 a 1,42 × 10-4 mol L-1. Os estudos mostram que as duas metodologias propostas são viáveis.
15

Estudos eletroqu?micos e te?ricos sobre a oxida??o de compostos org?nicos modelo no eletrodo de diamante dopado com boro: comportamento eletroqu?mico, mecanismos de oxida??o e DFT

Silva, ?mison Rick Lopes da 20 July 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-01-12T13:44:02Z No. of bitstreams: 1 AmisonRickLopesDaSilva_DISSERT.pdf: 3032672 bytes, checksum: 3706691ab11516af6b2311a9f7d98456 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-01-16T16:12:13Z (GMT) No. of bitstreams: 1 AmisonRickLopesDaSilva_DISSERT.pdf: 3032672 bytes, checksum: 3706691ab11516af6b2311a9f7d98456 (MD5) / Made available in DSpace on 2017-01-16T16:12:13Z (GMT). No. of bitstreams: 1 AmisonRickLopesDaSilva_DISSERT.pdf: 3032672 bytes, checksum: 3706691ab11516af6b2311a9f7d98456 (MD5) Previous issue date: 2016-07-20 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / A oxida??o eletroqu?mica ? um tipo de processo que pode ocorrer diretamente no ?nodo, a partir de uma transfer?ncia direta com a superf?cie, ou tamb?m atrav?s de uma oxida??o indireta mediante a gera??o de esp?cies ativas de oxig?nio as quais podem ser fisicamente adsorvidas (na forma de radicais hidroxila (?OH), ou quimicamente adsorvidas (oxig?nio se apresenta em estrutura de ?xido), na superf?cie do eletrodo. Esse processo est? relacionado ao tipo do material an?dico utilizado e a sua atividade eletrocatal?tica. Por?m, essa atividade pode ser tamb?m, prejudicada devido ? forma??o de filmes polim?ricos, rea??es paralelas de produ??o de oxidantes bem como, a rea??o de evolu??o de oxig?nio. Dentre os materiais eletrocatal?ticos mais estudados encontra-se os filmes de diamante dopado com boro (DDB). O eletrodo de DDB possui excelentes propriedades tais como estabilidade eletroqu?mica a elevadas densidades de correntes, estabilidade a corros?o, superf?cie inerte com baixas propriedades de adsor??o e dureza. A alta efici?ncia do DDB para remo??o dos compostos org?nicos ? atribu?da ? capacidade de produzir uma grande quantidade de radicais hidroxilas mediante a eletr?lise da ?gua. Estes radicais apresentam alta reatividade com os compostos org?nicos, devido ? sua fraca intera??o (fracamente adsorvido) com o filme de DDB s?o tamb?m, n?o seletivos e mineralizam completamente poluentes org?nicos com uma alta efici?ncia de corrente. Entretanto, alguns compostos org?nicos s?o de f?cil degrada??o em rela??o a outros, bem como, alguns compostos org?nicos tamb?m interagem com a superf?cie do DDB. Assim, devido ? necessidade de entender o processo qu?mico em escala molecular, a inclus?o de estudos te?ricos computacionais esta sendo de maior interesse, na qual s?o desenvolvidos c?lculos f?sico-qu?micos advindos da qu?mica qu?ntica, utilizando a Teoria do Funcional da Densidade (DFT). A DFT trata sistemas com muitos el?trons usando fun??es que representam a densidade eletr?nica das mol?culas a fim de se obter: propriedades eletr?nicas, cargas at?micas e energias dos intermedi?rios que comp?e a superf?cie de energia potencial de uma rea??o qu?mica, avaliar a estabilidade de modo comparativo entre compostos e entender os mecanismos de rea??o seguidos e propostos. Assim, o objetivo deste trabalho foi o uso de DDB para o estudo do comportamento eletroqu?mico de compostos org?nicos (hidroquinona, catecol, resorcinol, ?cido ac?tico, ?cido f?rmico e ?cido ox?lico) bem como o entendimento do processo de degrada??o, dos mesmos quando eletrolisados. Al?m disso, estudos computacionais referentes ao comportamento das esp?cies qu?micas frente ao eletrodo de DDB com a inten??o de obter as configura??es de intera??o do composto org?nico na superf?cie do eletrodo ou no entendimento de desvendar as intera??es entre as esp?cies oxidantes fortes em solu??o com os compostos org?nicos durante sua degrada??o. / The Electrochemical Oxidation is a kind of process that can occur directly at the anode from a direct transfer to the surface, or also by means of indirect oxidation by the generation of active oxygen species which can be physically adsorbed (in form of hydroxyl radical (? OH)), or chemically adsorbed (oxygen is present in oxide structure) on the electrode surface. this process is related to the type of anode material used and its electrocatalytic activity. However, this activity can also be impaired due to the formation of polymeric films, production of parallel oxidant reactions as well reaction of oxygen evolution. Among the most studied electrocatalytic material is diamond films doped with boron (BDD). the BDD electrode has excellent electrochemical properties such as stability at high current densities, corrosion stability, inert surface with low adsorption properties, and hardness. The high efficiency of the BDD for removal of organic compounds is attributed to their ability to produce a large amount of hydroxyl radicals by the electrolysis of water. These radicals have high reactivity with organic compounds, due to their weak interaction (weakly adsorbed) with the film BDD, they are also not selective and completely mineralize organic pollutants with a high current efficiency. However, some organic compounds are easy to degradation than others, as well as certain organic compounds also interact with the surface of BDD. Thus, because of the need to understand the chemical process at the molecular level, including computational theoretical studies that are of most interest, which are developed physico-chemical calculations arising from quantum chemistry, using Density Functional Theory (DFT). The DFT is systems with many electrons using functions representing the electron density of molecules in order to obtain electronic, atomic charges and derivatives of energy the potential energy surface of a chemical reaction, to evaluate the stability of the compounds and understand the reaction mechanisms followed and proposed. The objective of this work was the use of BDD to study the electrochemical behavior of organic compounds (hydroquinone, catechol, resorcinol, acetic acid, formic acid and oxalic acid) as well as the understanding of the degradation process of the same when in electrolysis. Moreover, computational studies on the behavior of chemical species across the BDD electrode with the intention of obtaining the organic compound interaction settings on the surface of the electrode or the understanding to unravel the interactions between strong oxidizing species in solution with organic compounds during its degradation.
16

Metomil: investigação eletroquímica e desenvolvimento de metodologias voltamétricas usando eletrodo de diamante dopado com boro / Methomyl: electrochemical research and development voltammetric methodologies using boron-doped diamond electrode

Costa, Daniel Jackson Estevam da 17 September 2013 (has links)
Made available in DSpace on 2015-05-14T13:21:30Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 3679854 bytes, checksum: 205bff7f378aac18a609a434ae6abfdd (MD5) Previous issue date: 2013-09-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Methomyl is a carbamate insecticide widely used to control pests in crops. It is a potential contaminant in groundwater (half-life of 50 weeks) showing harmful effects to fish, aquatic invertebrates, and mammals, reported several cases of human poisoning, affecting the central nervous system. In general, involves the analytical chromatographic methods, fluorometric, spectrophotometric fluorescence X-rays, and the use of cyclic voltammetry and amperometric biosensors with gold electrode, demonstrating the use of electrochemical methods for determination of methomyl. This study made use of an electrode of boron-doped diamond due to its intrinsic properties: wide potential window and low adsorption of organic molecules. Thus, we studied the electrochemical behavior of methomyl using CV, SWV and DPV, being proposed methodologies for the determination of methomyl by SWV and DPV. Through the study of pH, determined by means of VPD were observed five oxidation processes (Ep1  + 1,2 V, Ep2  + 1,6 V, Ep3  + 1,8 V, Ep4 ≈ +1,5 V and Ep5  + 0,8 vs. EAg/AgCl) on DDB cathodically polarized, being more sensitive P2. A methodology was developed using VOQ, being the best analysis conditions: pH 3.0 (BR buffer 0.1 mol L-1), f = 35 s 1, Es = 4 mV, Ep = 40 mV, td = 10 s and  = 1500 rpm, obtaining a linear range of 6,6 × 10 5 a 4,2 × 10 4 mol L-1, However, this method did not provide the acceptable recovery at the concentration studied level for methomyl, according to AOAC-I. The VPD technique was used as an alternative for the determination of methomyl. The best conditions for the analysis of VPD that provided the most sensitive voltammetric response were: pH 2.0 (BR buffer 0.1 mol L-1), IT = 0,2 s, Es = 4 mV, Ep = 50 mV, td =10 s and rpm. The material excellent response preconcentrate allowed the development of an analytical with a linearity range from 5.0 × 10-6 to 4.1 × 10-4 mol L-1 with limits of detection and quantification 1.2 × 10-6 and 4.1 × 10-6 mol L-1, respectively. The sensor showed good repeatability (RSD = 1.1%) and reproducibility (RSD = 1.7%), being feasible with recoveries around 87% for commercial formulations. / Metomil é um inseticida carbamato amplamente empregado no controle de pragas em culturas agrícolas. É um contaminante em potencial das águas subterrâneas (meia-vida de 50 semanas) apresentando efeitos nocivos aos peixes, invertebrados aquáticos e mamíferos, sendo relatados vários casos de envenenamento humano, prejudicando o sistema nervoso central. Em geral, sua determinação analítica envolve métodos cromatográficos, fluorimétricos, espectrofotométricos de fluorescência de raios X, além do uso de biossensores amperométricos e voltametria cíclica com eletrodo de ouro, demonstrando o uso de metodologias eletroquímicas para determinação de metomil. Neste estudo se fez uso de um eletrodo de diamante dopado com boro devido às suas propriedades intrínsecas: ampla janela de potencial e baixa adsorção de moléculas orgânicas. Assim, foi estudado o comportamento eletroquímico do metomil usando VC, VOQ e VPD, sendo propostas metodologias para a determinação de metomil por VOQ e VPD. Através do estudo de pH, realizado pela técnica VPD, foram observados cinco processos de oxidação (Ep1  + 1,2 V, Ep2  + 1,6 V, Ep3  + 1,8 V, Ep4 ≈ +1,5 V e Ep5  + 0,8 vs. EAg/AgCl) em DDB catodicamente polarizado, sendo P2 mais sensível. Uma metodologia empregando VOQ foi desenvolvida, sendo as melhores condições de análise: pH 3,0 (tampão BR 0,1 mol L 1), f = 35 s 1, Es = 4 mV, Ep = 40 mV, td = 10 s e  = 1.500 rpm, obtendo uma faixa linear de 6,6 × 10 5 a 4,2 × 10 4 mol L-1, contudo esse método não apresentou recuperação aceitável para o nível de concentração de metomil estudado, conforme AOAC-I. A técnica de VPD foi utilizada como uma alternativa para a determinação de metomil. As melhores condições de análise da VPD que proporcionaram a resposta voltamétrica mais sensível foram: pH 2,0 (tampão BR 0,1 mol L 1), IT = 0,2 s, Es = 4 mV, Ep = 50 mV, td =10 s e rpm. A excelente resposta do material pré-concentrado permitiu o desenvolvimento de uma metodologia analítica com uma faixa de linearidade de 5,0 × 10-6 até 4,1 × 10-4 mol L 1 com limites de detecção e quantificação de 1,2 × 10 6 e 4,1 × 10 6 mol L 1, respectivamente. O sensor apresentou repetibilidade (DPR = 1,1%) e reprodutibilidade (DPR = 1,7%), mostrando-se viável com recuperações em torno de 87% para formulações comerciais.
17

Determinação voltamétrica simultânea de paracetamol e cafeína e de ácido ascórbico e cafeína em formulações famacêuticas empregando um eletrodo de diamante dopado com boro / Simultaneous voltammetric determination of paracetamol and caffeine and ascorbic acid and caffeine in pharmaceutical formulations using a boron doped diamond electrode

Bruna Cláudia Lourenção 25 February 2010 (has links)
Neste trabalho descreve-se o desenvolvimento de procedimentos eletroanalíticos para a determinação de paracetamol, ácido ascórbico (AA) e cafeína em formulações farmacêuticas utilizando um eletrodo de diamante dopado com boro (BDD) e voltametria de pulso diferencial (DPV). Inicialmente, foram obtidos os voltamogramas cíclicos para o paracetamol, AA e cafeína separadamente sendo os potenciais de pico anódicos de oxidação de cada um destes analitos iguais a 0,80 V, 0,92 V e 1,47 V, respectivamente. O efeito do pré-tratamento eletroquímico do eletrodo de BDD nas medidas voltamétricas foi também objeto de estudo. Os parâmetros da voltametria de onda quadrada e voltametria de pulso diferencial também foram estudados e otimizados para cada analito. No primeiro procedimento desenvolvido, determinou-se simultaneamente paracetamol e cafeína em formulações farmacêuticas utilizando o eletrodo de BDD e voltametria de pulso diferencial após a otimização das condições experimentais. A curva analítica foi linear no intervalo de concentração de paracetamol e cafeína de 5,0 × 10-7 mol L-1 a 8,3 × 10-5 mol L-1 com limite de detecção iguail a 4,9 × 10-7 mol L-1 para paracetamol e 3,5 × 10-8 mol L-1 para cafeína. O desvio padrão relativo do paracetamol e da cafeína para a repetibilidade intra-dias foi de 0,7 % e 0,2% respectivamente e para a repetibilidade inter-dias foi de 5,1% e 1,4% respectivamente. A quantificação de paracetamol e cafeína em formulações farmacêuticas utilizando um eletrodo de BDD apresentaram resultados concordantes com os resultados obtidos empregando-se um método cromatográfico em um nível de confiança de 95%. Na seqüência, um segundo procedimento foi desenvolvido para a determinação simultânea de AA e cafeína em formulações farmacêuticas utilizando o eletrodo de BDD e voltametria de pulso diferencial, após a otimização das condições experimentais. A curva analítica foi linear num intervalo de concentração de 5,0 × 10-6 mol L-1 a 1,9× 10-4 mol L-1 para AA e de 2,0 × 10-6 mol L-1 a 1,1 × 10-4 mol L-1 para cafeína com limites de detecção de 2,6 × 10-7 mol L-1 para AA e 2,4 × 10-8 mol L-1 para cafeína. O desvio padrão relativo do AA e da cafeína para a repetibilidade intra-dias foi de 0,5% e 0,2% respectivamente e para a repetibilidade inter-dias foi de 5,9% e 8,7% respectivamente. A quantificação de AA e cafeína em formulações farmacêuticas utilizando um eletrodo de BDD apresentaram resultados concordantes com os resultados obtidos empregando-se um método cromatográfico em um nível de confiança de 95%. / In this study the development of eletroanalytical procedures for paracetamol, ascorbic acid (AA) and caffeine in pharmaceutical formulations using a boron doped diamond (BDD) and differential pulse voltammetry (DPV) is described. Initially, the cyclic voltammograms of paracetamol, AA and caffeine were separately obtained with the potentials of anodic peaks of oxidation of each one of these analytes equals to 0.80 V, 0.92 V and 1.47 V, respectively. The effect of electrochemical pre-treatment of the BDD electrode in voltammetric measurements was the purpose of this study, as well. The parameters of square wave voltammetry and differential pulse voltammetry were also studied and optimized for each analyte. In the first developed procedure, it was determined both paracetamol and caffeine in pharmaceutical formulations using the BDD electrode and differential pulse voltammetry after optimization of experimental conditions. The analytical curves were linear in the paracetamol and caffeine concentration intervals, ranging from 5.0 x 10-7 mol L-1 to 8.3 x 10-5 mol L-1 with detection limit equal to 4.9 x 10-7 mol L-1 for paracetamol and 3.5 x 10-8 mol L-1 for caffeine. The relative standard deviation of paracetamol and caffeine for the intra-day repeatability was 0.7% and 0.2% respectively, and the inter-day repeatability was 5.1% and 1.4% respectively. The quantification of paracetamol and caffeine in pharmaceutical formulations using a BDD electrode showed results in agreement with those results obtained using a chromatographic method at a 95% confidence level. Subsequently, a second procedure was developed for the simultaneous determination of AA and caffeine in pharmaceutical formulations using the BDD electrode and differential pulse voltammetry, after optimization of experimental conditions. The analytical curves were linear in the concentrations ranging from 5.0 x 10-6 mol L-1 to 1.9 x 10-4 mol L-1 for AA and 2.0 x 10-6 mol L-1 to 1.0 x 10-4 mol L-1 for caffeine with detection limits of 2.6 x 10-7 mol L-1 for AA and 2.4 x 10-8 mol L-1 for caffeine. The relative standard deviation of AA and caffeine for the intra-day repeatability was 0.5% and 0.2% respectively, and the inter-day repeatability was 5.9% and 8.7% respectively. Quantification of AA and caffeine in pharmaceutical formulations using a BDD electrode showed results in accordance with the results obtained using a chromatographic method at a 95% confidence level.
18

Determina??o de sildenafila (Viagra?) e carbamazepina em formula??es farmac?uticas por amperometria de m?ltiplos pulsos em sistema FIA / Determination of sildenafil (Viagra?) and carbamazepine in pharmaceutical formulations by multiple pulses amperometry in FIA system

Lopes J?nior, Ant?nio Carlos Vieira 27 July 2012 (has links)
Submitted by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-02-19T13:03:28Z No. of bitstreams: 5 carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-02-20T09:21:34Z (GMT) No. of bitstreams: 5 license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2015-02-20T09:21:34Z (GMT). No. of bitstreams: 5 license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2013-02-21 / O presente trabalho apresenta m?todos simples, r?pidos e de baixo custo para determina??o de citrato de sildenafila (CS) e carbamazepina (CBZ) em formula??es farmac?uticas atrav?s da detec??o amperom?trica de m?ltiplos pulsos (MPA) em sistema de an?lise por inje??o em fluxo (FIA) utilizando como eletrodo de trabalho o diamante dopado com boro (DDB). O m?todo para determina??o de CS consiste na aplica??o de tr?s pulsos de potencial em sequ?ncia. Os pulsos de potencial de 1,6 V e 1,9 V s?o utilizados para detec??o eletroqu?mica do f?rmaco e um terceiro pulso de potencial (1,0 V) para promover a limpeza e reativa??o da superf?cie do eletrodo de DDB. Os limites de detec??o (LD) obtido nas condi??es estabelecidas est?o na ordem de 10 nmol L-1 para ambos os potenciais de detec??o. O desvio padr?o relativo das respostas de 10 inje??es consecutivas de CS na concentra??o de 4,5x10-5 mol L-1 foi de 0,1 e 0,2% para os pulsos de potencial de detec??o de 1,9 V e 1,6 V, respectivamente. Os estudos de adi??o e recupera??o de CS padr?o foram realizados em todas as amostras farmac?uticas apresentando recupera??o, em todos os casos, pr?ximo de 100%. Os resultados de doseamento dos medicamentos realizados a partir do m?todo proposto foram validados por metodologia cromatogr?fica. Para a CBZ foram propostas duas vertentes anal?ticas, uma voltada para determina??o do ativo em amostras farmac?uticas e outra para detec??o do f?rmaco em fluidos biol?gicos. Alguns par?metros foram semelhantes em ambos os procedimentos, s?o eles: eletr?lito suporte (?cido sulf?rico 0,2 mol L-1), vaz?o (3,0 mL min-1), volume de amostragem (150 ?L), potencial de limpeza (-1,4 V) e tempo de aplica??o deste potencial (600 ms). Al?m destes par?metros, para an?lise do f?rmaco em produto farmac?utico, foram utilizados para detec??o os pulsos de potenciais 1,6 e -1,2V, sendo aplicados por 150 e 30 ms, respectivamente. Nestas condi??es, foram obtidas as seguintes faixas lineares de trabalho: 0,6 a 40,0 ?mol L-1 para o pulso de potencial de 1,6 V e 0,4 a 20,0 ?mol L-1 para o pulso de potencial de -1,2 V. Para determina??o de CBZ em fluido biol?gico adotou-se como sistema de detec??o o pulso de potencial de 1,6 V aplicado por 800 ms (gerador) e o pulso de potencial de -1,2 V aplicado por 30 ms (detector). Para este pulso de potencial foi obtida faixa linear de trabalho de 0,02 a 1,0 ?mol L-1 e LD de 1,78 nmol L-1. Os estudos de adi??o e recupera??o de CBZ padr?o em amostras farmac?uticas e urina apresentaram resultados pr?ximos de 100%. Os resultados do ensaio de doseamento de medicamentos, realizados pelo m?todo proposto, foram validados por meio de metodologia oficial. Este trabalho apresenta, pela primeira vez, m?todos para determina??o de CS e CBZ em formula??es farmac?uticas atrav?s da detec??o MPA em sistema FIA. A associa??o desta t?cnica ao eletrodo de trabalho de DDB permitiu o desenvolvimento de m?todos de elevada sensibilidade, seletividade, rapidez e reprodutibilidade, demonstrando not?vel potencialidade para aplica??o no controle de qualidade de rotina de CS e CBZ em laborat?rios farmac?uticos e farm?cias de manipula??o. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2012. / ABSTRACT The present work presents simple, fast and low-cost methods for determination of sildenafil citrate (CS) and carbamazepine (CBZ) in pharmaceutical formulations using flow injection analysis (FIA) with multiple pulse amperometric (MPA) detection on the boron-doped diamond (DDB) working electrode. The method for the CS determination consists of the application of three sequential potential pulses as function of the time. SC is detected at 1.6 V and 1.9 V by two different irreversible oxidation processes. The third potential pulse (1.0 V) is applied for the regeneration (cleaning) of the electrode (boron-doped diamond) surface. The limit of detection (LD) in an order of 10 nmol L-1 was reached with a standard deviation of less than 0.2 % (n = 10) for 4.5 x 10-5 mol L-1 CS. The analytical frequency was calculated in 86 injections per hour. The addition-recovery studies in all the samples were around 100% and the results were validated by chromatographic methods. For the CBZ determination, two analytic conditions were proposed, one used for determination of a drug in pharmaceutical samples and other for detection the active ingredient in biological fluids. Some parameters were similar in both procedures, they are: supporting electrolyte (sulfuric acid 0.2 mol L-1), flow (3.0 ml min-1), sampling volume (150 ?L), regeneration potential pulse (-1.4 V) and time of application of this potential (600 ms). In addition to these parameters, for analysis of pharmaceutical drug, were used to detect it the potential pulses 1.6 V and -1.2 V, being applied for 150 and 30 ms, respectively. These conditions provided linear range of 0.6 to 40.0 ?mol L -1 for potential pulse 1.6 V and 0.4 to 20.0 ?mol L-1 for potential pulse -1.2 V. For the CBZ determination in biological fluid adopted as detection system the potential pulse of 1.6 V applied for 800 ms (generator) and potential pulse of -1.2 V applied for 30 ms (detector). For this potential pulse the linear range was of 0.02 to 1.0 ?mol L-1 and the LD was 1.78 nmol L-1. The addition-recovery studies in all the samples were around 100 % and the results were validated by official method. This work presents for the first time methods of SC and CBZ determination in pharmaceutical formulations utilizing MPA detection coupled to an FIA system. This technique, associated with a BDD working electrode, provided a sensitive, selective, fast and highly reproducible methods. Thus, the proposed methods may be an extremely attractive alternative for routine large and small-scale CS and CBZ analysis.
19

Desenvolvimento de procedimentos eletroanalíticos para a determinação simultânea de analgésicos em formulações farmacêuticas e fluidos biológicos empregando o eletrodo de diamante dopado com boro

Santos, Anderson Martin dos 30 July 2015 (has links)
Submitted by Alison Vanceto (alison-vanceto@hotmail.com) on 2016-09-19T13:08:42Z No. of bitstreams: 1 DissAMS.pdf: 9742960 bytes, checksum: 9f8e053fcda7ed507c68927b7c6c5533 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-21T18:19:00Z (GMT) No. of bitstreams: 1 DissAMS.pdf: 9742960 bytes, checksum: 9f8e053fcda7ed507c68927b7c6c5533 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-21T18:19:07Z (GMT) No. of bitstreams: 1 DissAMS.pdf: 9742960 bytes, checksum: 9f8e053fcda7ed507c68927b7c6c5533 (MD5) / Made available in DSpace on 2016-09-21T18:19:16Z (GMT). No. of bitstreams: 1 DissAMS.pdf: 9742960 bytes, checksum: 9f8e053fcda7ed507c68927b7c6c5533 (MD5) Previous issue date: 2015-07-30 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / In this master dissertation, electroanalytical procedures for the simultaneous determination of analgesics paracetamol (PAR) and codeine (COD) and, PAR and tramadol (TRA) in pharmaceutical samples and biological fluids using a cathodically pretreated boron-doped diamond electrode (BDDE) were developed. In the first procedure, the square-wave voltammetry (SWV) was employed for the simultaneous determination of PAR and COD, using as supporting electrolyte 0.2 mol L−1 acetate buffer (pH 4.0), and the analytical curves were linear in the concentration range from 0.2 to 95.8 μmol L−1 for PAR and from 0.2 to 95.8 μmol L−1 for COD, with detection limits (LODs) of 0.018 μmol L−1 and 0.014 μmol L−1, respectively. The second procedure developed for the simultaneous determination of PAR and COD was based on a flow injection analysis with multiple pulses amperometric detection (FIA-MPA), using as transport solution a 0.05 mol L−1 H2SO4 solution. The potential pulse application sequence in function of time was 950 mV / 200 ms (potential where only the PAR oxidation occurs) and 1400 mV / 100 ms (potential where both analytes suffers oxidation (PAR and COD)). The obtained analytical curves show linearity from 0.08 to 100.0 μmol L−1 for PAR and 0.05 to 10.0 μmol L−1 for COD, with LODs of 0.030 e 0.035 μmol L−1 for PAR and COD, respectively. The analytical frequency was estimated as being 90 determinations h−1. After, an electroanalytical procedure using FIA–MPA it was developed a simultaneous determination of PAR and TRA. The potential pulse application sequence in function of time was 850 mV / 200 ms (potential where only occurs the PAR oxidation) and 1600 mV / 100 ms (potential where both analytes suffers oxidation). The obtained analytical curves show linearities between 1.0 to 100.0 μmol L−1 and 0.08 to 10.0 μmol L−1 for PAR and TRA, respectively, and the LOD was 0.030 μmol L−1 for PAR and 0.040 μmol L−1 for TRA. Finally, all developed procedures were employed for the simultaneous determination of these compounds (PAR + COD e PAR + TRA) in pharmaceutical samples, where the obtained results agree with those results obtained using a comparative method (HPLC – High-performance liquid chromatography). These compounds were simultaneously analyzed in synthetic biological fluids (urine and human serum) by addiction and recuperation method, where the recuperations obtained ranged from 90.8 to 108%. / Neste trabalho de mestrado foram desenvolvidos procedimentos eletroanalíticos para a determinação simultânea dos analgésicos paracetamol (PAR) e codeína (COD) e de PAR e tramadol (TRA) em amostras farmacêuticas e fluidos biológicos utilizando-se o eletrodo de diamante dopado com boro (BDDE) prétratado catodicamente. Para o primeiro procedimento, empregou-se a voltametria de onda quadrada (SWV) para a determinação simultânea de PAR e COD em tampão acetato 0,2 mol L−1 (pH 4,0) como eletrólito suporte, obtendo-se curvas analíticas lineares nos intervalos de concentração de 0,2 a 95,8 μmol L−1 para PAR e de 0,4 a 9,6 μmol L−1 para COD e limites de detecção (LDs) de 0,018 e de 0,014 μmol L−1 respectivamente para o PAR e COD. O segundo procedimento desenvolvido para a determinação simultânea dos analgésicos PAR e COD foi por análise por injeção em fluxo com detecção amperométrica de múltiplos pulsos (FIA–MPA) em solução transportadora de H2SO4 0,05 mol L−1. A sequência de aplicação dos pulsos em função do tempo foi de 950 mV / 200 ms (pulso de potencial no qual ocorre a oxidação apenas do PAR) e de 1400 mV / 100 ms (pulso de potencial no qual ocorre a oxidação de ambos os analitos (PAR e COD)). As curvas analíticas obtidas apresentaram linearidades de 0,08 a 100,0 μmol L−1 para PAR e de 0,05 a 10,0 μmol L−1 para COD e os LDs foram de 0,030 e 0,035 μmol L−1 para PAR e COD, respectivamente. A frequência analítica obtida foi de 90 determinações h−1. O terceiro procedimento foi desenvolvido empregando-se FIA–MPA para a determinação simultânea de PAR e TRA. Uma sequência de aplicação dos pulsos de potencial em função do tempo foram de 850 mV / 200 ms (pulso de potencial no qual ocorre a oxidação apenas de PAR) e de 1600 mV / 100 ms (pulso de potencial no qual ocorre a oxidação de PAR e TRA). As curvas analíticas obtidas apresentaram linearidades de 1,0 a 100,0 μmol L−1 e de 0,08 a 10,0 μmol L−1 para PAR e TRA, respectivamente, com LDs de 0,030 μmol L−1 para o PAR e de 0,040 μmol L−1 para o TRA. Finalmente, todos os procedimentos desenvolvidos foram empregados para a determinação simultânea destes compostos (PAR + COD e PAR + TRA) em amostras farmacêuticas, sendo os resultados obtidos concordantes com os resultados obtidos empregando-se o método comparativo (HPLC – cromatografia líquida de alta eficiência). Estes analgésicos também foram determinados simultaneamente em fluidos biológicos sintéticos (urina e soro humano) pelo método de adição e recuperação, sendo obtidas recuperações entre 90,8 a 108%.
20

DetecÃÃo EletroanalÃtica e Estudo do Mecanismo de OxidaÃÃo do Pesticida Dimetomorfe / Electroanalytical Detection and Oxidation Mechanism Study of Dimethomorph Pesticide.

Francisco Willian de Souza Lucas 17 July 2012 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / O Dimetomorfe (DIM) pertence à classe dos fungicidas morfolÃnicos, tem aÃÃo sistÃmica, à persistente nas matrizes alimentÃcias e em solos de plantio onde foi aplicado e à um possÃvel interferente endÃcrino, o que justifica o desenvolvimento de metodologias para detecÃÃo e quantificaÃÃo desse composto. No estudo eletroquÃmico pode-se observar que DIM apresentou processo eletroquÃmico controlado por difusÃo e caracterizado como quasi-reversÃvel, com potencial de eletrodo em torno de 1,28 V vs. eletrodo de Ag/AgCl/Cl-(KCl sat.), referente à transferÃncia de dois elÃtrons. No desenvolvimento da metodologia eletroanalÃtica utilizando voltametria de onda quadrada e o eletrodo de diamante dopado com boro, constatou-se que as melhores condiÃÃes experimentais e voltamÃtricas foram obtidas em tampÃo Britton-Robinson pH 3, como eletrÃlito de suporte, frequÃncia de aplicaÃÃo dos pulsos de potencial de 30 s-1, amplitude dos pulsos de potencial de 50 mV e incremento de potencial de 2 mV. Partindo dessas condiÃÃes foi possÃvel desenvolver uma metodologia analÃtica com faixa linear de 4,57x10-6 a 3,78x10-4 mol L-1, limite de detecÃÃo de 3,11x10-7 mol L-1, limite de quantificaÃÃo de 1,04x10-6 mol L-1, repetibilidade de 0,13% (n = 10) e reprodutibilidade de 0,92% (n = 5). A avaliaÃÃo da interferÃncia das espÃcies iÃnicas presentes no eletrÃlito de suporte e do Mancozebe (MZB), presente em coformulaÃÃes de DIM, na exatidÃo e na precisÃo da metodologia mostrou que essas espÃcies exercem pouca influÃncia. A recuperaÃÃo em eletrÃlito foi de 97,25  0,70 %, com confianÃa de 95%, e BIAS de 2,74 %. O percentual de interferÃncia do MZB, em diferentes concentraÃÃes, foi menor que |10%|. A aplicaÃÃo da metodologia proposta na determinaÃÃo do DIM em uva in natura e em vinho tinto apresentou percentual de recuperaÃÃo de 101,0  12,1% e 105,1  10,8% com confianÃa de 95%, respectivamente, e BIAS menor que 6%. Baseando-se nas informaÃÃes quÃmico-computacionais, pode-se inferir que o sÃtio de oxidaÃÃo do DIM à na dupla ligaÃÃo nÃo aromÃtica. Os dados obtidos por cromatografia gasosa acoplada a um espectrÃmetro de massa levaram à conclusÃo que a natureza do substrato eletrÃdico nÃo interfere no mecanismo global da reaÃÃo de eletrooxidaÃÃo do DIM, sendo formado o (4-clorofenil)-(3,4-dimetoxifenil)metanona como produto majoritÃrio. / Dimethomorph (DIM) belongs to the class of morpholinic fungicides, it has systemic action, it is persistent in food matrices and in planting soils where was applied and a possible endocrine interferent, justifying the development of methodologies for detection and quantification of this compound. In the electrochemical study can be seen that the DIM had electrochemical process diffusion-controlled and characterized as quasi-reversible, with electrode potential of approximately 1.28 V vs. Ag/AgCl/Cl-(KCl sat.) electrode and involving two electrons transfer. In the development of electroanalytical methods using the square-wave voltammetry and the boron-doped diamond electrode, it was found that the best experimental and voltammetric conditions were obtained in Britton-Robinson buffer pH 3, as supporting electrolyte, pulse potential frequency of 30 s-1, square-wave amplitude of 50 mV and potential step increment of 2 mV. From these conditions it was possible to develop an analytical method with a linear range from 4.57x10-6 to 3.78x10-4 mol L-1, detection limit of 3.11x10-7 mol L-1, quantification limit of 1.04x10-6 mol L-1, 0.13% of repeatability (n = 10) and 0.92% of reproducibility (n = 5). The evaluation of the interference of the ionic compounds present in the supporting electrolyte and the Mancozebe (MZB), present in DIM co-formulations, in the accuracy and precision of the methodology showed that these species have little influence. The recovery in electrolyte was of 97.25  0.70%, with 95% confidence, and BIAS of 2.74%. The percentage of MZB interference, in different concentrations, was less than |10%|. The application of the proposed methodology for determining of the DIM in fresh grapes and red wine showed a percent recovery equal to 101.0  12.1% and 105.1  10.8% with 95% confidence, respectively, and BIAS less than 6 %. Based on the quantum-chemicals information, we can infer that the site of oxidation of DIM is the non-aromatic double bond. The data obtained by gas chromatography-mass spectrometry led to the conclusion that the electrodic substrate nature does not interfere in the overall mechanism of the DIM electrooxidation reaction, in which is formed the (4-chlorophenyl)-(3,4-dimethoxyphenyl)methanone as major product.

Page generated in 0.1138 seconds