• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento do eletrodo de filme de bismuto depositado sobre cobre para aplicações eletroanalíticas

Nunes, Luiza Maria da Silva 04 April 2007 (has links)
Made available in DSpace on 2016-06-02T20:36:15Z (GMT). No. of bitstreams: 1 1914.pdf: 1826577 bytes, checksum: a6e664234adbf59c06d53c3beca9c0e1 (MD5) Previous issue date: 2007-04-04 / Universidade Federal de Sao Carlos / On this work is described the development of bismuth film electrode deposited over copper substrate for electroanalytical applications. The bismuth film electrode was deposited ex situ over a copper substrate. The electrodeposition of Bi was carried out applying a constant potential of -150 mV during 300 s. The plating solution was composed by 0.02 mol L-1 Bi(NO)3 in 1.0 mol L-1 hydrochloride acid with or not 0.08 mol L-1 sodium citrate, the electrodes obtained from these solutions were nominated Bi-Cit008 and Bi-HCl, respectively. The bismuth film characterization was carried out by Field Emission Gun Scanning Electron Microscopy (FEG-SEM), Scanning Electron Microscopy with Energy Dispersive X-ray analysis (MEV-EDX) and X-Ray Diffraction analysis. The FEG-SEM and MEV-EDX analysis of bismuth film showed that the morphology of the deposits were strongly dependent of the plating solution composition. X-Ray diffraction analysis showed a single rhombohedral and cubic phase for the two bismuth film electrodes analyzed. The Bi-HCl and Bi-Cit008 electrodes showed a good cathodic potential window from -300 mV to -1200 mV. Both electrodes, exhibited a good analytical response for cadmium and lead by means of square wave anodic stripping voltammetry technique. For the lead determination, Bi-HCl and Bi-Cit008 electrodes showed a detection limit of 2.8 x 10-8 mol L-1 and 2.5 x 10-8 mol L-1, respectively in a concentration range from 9.6 x 10-6 to 5.7 x 10-5 mol L-1. For the cadmium determination, Bi-HCl and Bi-Cit008 electrodes presented a detection limit of 1.1 x 10-6 mol L-1 and 6.3 x 10-8 mol L-1, respectively in the concentration range from 1.7 x 10-5 to 12.3 x 10-5 mol L-1. Both electrodes, presented analytical response with good resolution without baseline dislocation, therefore, Bi-Cit008 had best analytical performance. / Neste trabalho é descrito o desenvolvimento de eletrodo de filme de bismuto depositado sobre cobre para aplicações eletroanalíticas. O bismuto foi depositado sobre cobre por meio de deposição ex situ. O potencial de deposição escolhido para a formação de um filme de aspecto mais uniforme foi de -150 mV em 300 s. A solução de eletrodeposição utilizada foi nitrato de bismuto 0,02 mol L-1 em meio de ácido clorídrico 1,0 mol L-1 com e sem a adição de citrato de sódio 0,08 mol L-1, os eletrodos de filmes de bismuto obtidos a partir dessas soluções foram nomeados de Bi-Cit008 e Bi-HCl, respectivamente. Os eletrodos de filme de bismuto foram caracterizados por meio das técnicas de microscopia eletrônica de varredura de alta resolução (FEG-SEM), microscopia eletrônica de varredura com análise de energia dispersiva (MEV-EDX) e difração de raios-X. As análises de FEG-SEM e MEV mostraram que diferentes condições de síntese influenciaram as características da morfologia e a composição química do filme de bismuto. As análises de difração de raios-X apresentaram fases cristalinas romboédricas e cúbicas para ambos os eletrodos de filme de bismuto. Os eletrodos Bi-HCl e Bi-Cit008 apresentaram uma boa janela de potencial catódico de -300 mV a -1200 mV. Os eletrodos Bi-HCl e Bi-Cit008 mostraram uma boa resposta analítica por meio de voltametria de redissolução anódica por onda quadrada para soluções contendo cádmio e chumbo. Para a determinação de chumbo, os eletrodos Bi- HCl e Bi-Cit008 apresentaram limite de detecção de 2,8 x 10-8 mol L-1 e de 2,5 x 10-8 mol L-1, respectivamente, para a faixa de concentração de 9,6 x 10-6 mol L-1 a 5,7 x 10-5 mol L-1. Para a determinação de cádmio, os eletrodos de Bi-HCl e Bi-Cit008 apresentaram limites de detecção de 1,1 x 10-6 mol L-1 e de 6,3 x 10-8 mol L-1, respectivamente, para a faixa de concentração de 1,7 x 10-5 mol L-1 a 12,3 x 10-5 mol L-1. Ambos os eletrodos apresentaram resposta analítica com boa resolução e sem deslocamento da linha base, no entanto, o eletrodo de Bi-Cit008 apresentou melhor desempenho analítico.
2

Desenvolvimento de minissensores de filme de bismuto para a determinação voltamétrica in loco de atrazina, diquat e paraquat em águas naturais / Development of bismuth film minissensors for in loco voltammetric determination of atrazine, diquat and paraquat in natural waters

Figueiredo Filho, Luiz Carlos Soares de 25 February 2011 (has links)
Made available in DSpace on 2016-06-02T20:36:29Z (GMT). No. of bitstreams: 1 3452.pdf: 2283262 bytes, checksum: b35fc0c6b1b4c5e555f369b4a79c729a (MD5) Previous issue date: 2011-02-25 / Universidade Federal de Minas Gerais / The development of bismuth film electrodes (BiFE) and minissensors/BiFE for application to the development of electroanalytical procedures for determination of atrazine, Diquat and Paraquat using voltammetric techniques as square wave (SWV) and differential pulse (DPV) is reported in this work. It was chosen to combine the working electrode (BiFE), pseudo-reference (silver glue) and counter (copper) in the same bracket for easily locomotion of the electrochemical system for field analysis. Copper plates of printed circuit were used as substrate and nail polish was used as an electrical insulator to limit the active area. Thus it was possible to make a minissensor with low cost. For the first procedure developed it was determined atrazine in natural waters using BiFE and DPV after the optimization of experimental conditions was obtained an analytical curve linearity for the range from 6.6 x 10-7 to 2.0 x 10-5 mol L-1, with a limit of detection of 1.4 x 10-7 mol L-1. Subsequently, parameters of the SWV technique for determination of Diquat in water samples were studied using BiFE and minissensor/BiFE and the linear correlation was obtained for a concentration range from 1.9 to 5.6 x 10-7 x 10-6 mol L-1 and from 1.9 x 10-7 to 9.3 x 10-6 mol L-1 respectively, and the limit of detection obtained were 8.7 x 10-8 mol L-1 and 8.9 x 10-8 mol L-1. Finally a procedure was developed for the determination of Paraquat using BiFE and minissensor/BiFE by DPV. For the BiFE a linear relationship was obtained for the concentration range from 6.6 x 10-7 to 4.8 x 10-5 mol L-1, with a limit of detection of 9.3 x 10-8 mol L-1. After being selected the best experimental conditions for minissensor/BiFE, it responded to a linear concentration range from 6.6 x 10-8 to 3.9 x 10-6 mol L-1 with a limit of detection of 1,2 x 10-8 mol L-1. / No presente trabalho descreve-se o desenvolvimento de eletrodos de filme de bismuto (BiFE) e minissensores/BiFE para posterior aplicação no desenvolvimento de procedimentos eletroanalíticos para a determinação de Atrazina, Diquat e Paraquat utilizando-se as técnicas voltamétricas de onda quadrada (SWV) e de pulso diferencial (DPV). Na confecção do minissensor optou-se em design que reunisse o eletrodo de trabalho (BiFE), pseudo-referência (cola de prata) e auxiliar (cobre) em um mesmo suporte para mais fácil locomoção do sistema eletroquímico para determinações em campo. Utilizaram-se placas de cobre de circuito impresso como substrato e esmaltes de unha como isolante elétrico para delimitar a área ativa dos eletrodos. Desta maneira foi possível a realização de um minissensor de baixo custo. Para o primeiro procedimento desenvolvido determinou-se Atrazina em águas naturais utilizando-se o BiFE e a DPV após as otimizações das condições experimentais obteve-se uma curva analítica no intervalo de concentração de Atrazina de 6,6 x 10-7 a 2,0 x 10-5 mol L-1, com limite de detecção de 1,4 x 10-7 mol L-1. Em seqüência foi estudado os parâmetros da técnica de SWV para a determinação de Diquat em amostras de águas naturais utilizando BiFE e o minissensor/BiFE sendo que a resposta linear obtida foi para o intervalo de concentração de 1,9 x 10-7 a 5,6 x 10-6 mol L-1 e 1,9 x 10-7 a 9,3 x 10-6 mol L-1 respectivamente e limites de detecção de 8,7 x 10-8 mol L-1 e 8,9 x 10-8 mol L-1. Finalmente foi desenvolvido um procedimento para a determinação de Paraquat através da DPV utilizando o BiFE e o minissensor/BiFE. Para o BiFE obteve-se uma relação linear no intervalo de concentração de 6,6 x 10-7 a 4,8 x 10-5 mol L-1, com limite de detecção de 9,3 x 10-8 mol L-1. Após serem avaliadas as melhores condições experimentais para o minissensor/BiFE, este respondeu de maneira linear para um intervalo de concentração de 6,6 x 10-8 a 3,9 x 10-6 mol L-1, com limite de detecção de 1,2 x 10-8 mol L-1.
3

Determinação simultânea de Cd, Pb e Cu em amostras de chá (Camellia sinensis) por voltametria de onda quadrada e redissolução anódica

Medeiros, Cleilson Lucena de 31 August 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2016-05-04T13:53:54Z No. of bitstreams: 1 arquivo total.pdf: 4473867 bytes, checksum: e3130e71f9f870684d06304ce755007d (MD5) / Made available in DSpace on 2016-05-04T13:53:54Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 4473867 bytes, checksum: e3130e71f9f870684d06304ce755007d (MD5) Previous issue date: 2015-08-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This paper describes the development of a method for quantification Cd2+, Pb2+ and Cu2+ cations, in teas, performed simultaneously, using Square Wave Anodic Stripping Voltammetry carbon nanotube paste electrode modified with bismuth film. Tea is one of the most beneficial and consumed beverage through the world, being prepared from the infusion parts of the plant Camellia sinensis. Most commonly this kind of tea presents metal ions, such as Cd 2+, Pb 2+ and Cu 2+, which offers health risk, in case of being ingested above the limit. To detect these metals, it is necessary to make use of techniques with high sensitivity. The spectrometric methods are the most widely used, but they have a high cost, are laborious and expensive. The voltammetric techniques are characterized by being inexpensive and having equal sensitivity, and even greater than some spectrometric methods. The parameters of the technique used were obtained after optimization with fractional factorial design. The tea samples were prepared through digestion with heating by microwave radiation in a closed system using diluted nitric acid and hydrogen peroxide. The method was validated based on the sample certified plant tissue (forage Marandu) and applied in green and black tea samples. Recoveries of cations Cd 2+, Pb 2+ and Cu 2+ ranged from 79.3 to 107.6%, the certified sample, and 73.3 to 122.1% in the evaluated samples of teas. The detection limits obtained in the simultaneous analysis of Cd 2+, Pb 2+ and Cu 2+ were 0.16; 0.20; 0.39 ug L-1, respectively. Cu2 + was detected only in samples of tea, but the method was efficient for the simultaneous quantification of all metals in the matrix assessed after the addition and recovery. / Este trabalho descreve o desenvolvimento de um método de quantificação dos cátions Cd2+, Pb2+ e Cu2+, em chás, realizada de forma simultânea, empregando voltametria de onda quadrada por redissolução anódica com eletrodo de pasta de nanotubo de carbono modificado por filme de bismuto. O chá é uma das bebidas mais benéficas e consumidas no mundo, sendo preparado a partir da infusão de partes da planta Camellia sinensis. Normalmente são encontrados cátions metálicos, como o Cd2+, Pb2+ e Cu2+, que se ingeridos acima do limite máximo representam riscos à saúde. Para detectar esses metais é necessário fazer uso de técnicas com alta sensibilidade. Os métodos espectrométricos são os que mais amplamente tem sido utilizado, porém apresentam custo elevado, são laboriosos e dispendiosos. As técnicas voltamétrica caracterizam-se por serem baratas e possuir sensibilidade igual e até maior que alguns métodos espectrométricos. Os parâmetros da técnica utilizada foram obtidos após otimização com planejamento fatorial fracionário. As amostras de chá foram preparadas via digestão com aquecimento por radiação micro-ondas em sistema fechado empregando ácido nítrico e peróxido de hidrogênio diluídos. A validação do método foi realizada com base na amostra certificada de tecido vegetal (forrageira Marandu) e aplicada em amostras de chá verde e preto. As recuperações dos cátions Cd2+, Pb2+ e Cu2+ variaram de 79,3 a 107,6%, na amostra certificada, e de 73,3 a 122,1% nas amostras de chás avaliadas. Os limites de detecção obtidos na análise simultânea de Cd2+, Pb2+ e Cu2+, foram 0,16; 0,20; 0,39 μg L-1, respectivamente. Foi detectado apenas Cu2+ nas amostras de chá, porém o método se mostrou eficiente para quantificação simultânea de todos os metais na matriz avaliada após a adição e recuperação.

Page generated in 0.0626 seconds