• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 713
  • 16
  • 12
  • 12
  • 12
  • 10
  • 9
  • 3
  • 1
  • 1
  • Tagged with
  • 734
  • 286
  • 273
  • 196
  • 173
  • 165
  • 152
  • 148
  • 148
  • 141
  • 140
  • 138
  • 121
  • 104
  • 102
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
651

ANÁLISE DO RISCO DOS CONTRATOS DE ENERGIA ELÉTRICA DAS CONCESSIONÁRIAS DE DISTRIBUIÇÃO / ANALYSIS OF THE RISK OF CONTRACTS OF ELECTRICAL ENERGY CONCESSIONAIRES DISTRIBUTION

Mendonça, Fernando José Moreira 19 March 2008 (has links)
Made available in DSpace on 2016-08-17T14:52:44Z (GMT). No. of bitstreams: 1 Fernado Jose Moreira Mendonca.pdf: 1350313 bytes, checksum: e72c7c0c53c0eb514a42a7aae28f2cde (MD5) Previous issue date: 2008-03-19 / This work presents an analysis of the new environment of purchasing electric energy, as well as the study s methodology for contracting. The objective of the distribution agents is to keep, in the current process of decision-making for contracting energy, a strategic purchase of energy within the limits of repasse the tariffs of electric energy. It proposes a strategy considering a number of actions to minimize the risks of sub and over hiring in the new environment of the electric sector. It is also held a detailed analysis of the parameters related to the procedures of contracting electrical power to enable a better understanding of the risks inherent in this process. The proposed strategy is applied to case studies and the results demonstrate the usefulness of the proposed methodology that minimizes the risk of contracting. The analysis of the results of the strategies of hiring concluded that the comfort level of coverage should be maintained in the level of 101.5%, in face of the possibilities of variations of scenarios of market forecast. / Neste trabalho é apresentada uma análise do novo ambiente de contratação de energia elétrica, bem como o estudo da metodologia de contratação. O objetivo dos agentes de distribuição é manter, no processo atual de tomada de decisão para a contratação de energia, uma estratégica de compra de energia dentro dos limites de repasse às tarifas de energia elétrica. É proposta uma estratégia considerando um conjunto de ações no sentido de minimizar os riscos de sub e sobre contratação dentro do novo ambiente do setor elétrico. Igualmente é realizada uma análise detalhada dos parâmetros relacionados com o procedimento de contratos de energia elétrica para permitir um melhor entendimento dos riscos inerentes neste processo. A estratégia proposta é aplicada a estudos de caso e os resultados demonstram a utilidade da metodologia proposta que minimiza os riscos de contratação. Da análise dos resultados das estratégias de contratação conclui-se que o nível de conforto de cobertura deve manter no patamar de 101,5%, em face das possibilidades de variações de cenários de previsão de mercado.
652

CARACTERIZAÇÃO METROLÓGICA DE UM MEDIDOR VOLUMÉTRICO PARA PEQUENAS TAXAS DE FLUXO DE GÁS UTILIZANDO O MÉTODO DE DIFERENÇA DE PRESSÃO / CHARACTERIZATION OF A GAUGE METROLOGICAL VOLUMETRIC FOR SMALL FLOW RATE OF GAS USING THE METHOD PRESSURE DIFFERENCE

Abreu, Pedro Augusto Lopes 16 March 2011 (has links)
Made available in DSpace on 2016-08-17T14:53:15Z (GMT). No. of bitstreams: 1 Pedro Augusto Lopes Abreu.pdf: 1389353 bytes, checksum: 81ce9ae4d3b6d093a60100d28069418b (MD5) Previous issue date: 2011-03-16 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A system for measuring low rates of gas flow has great importance for some industrial and especially for scientific applications where usually high accuracy and low uncertainty are required. This type of measurement systems have undergone a great development in recent years primarily due to the concern with the release of gases in natural processes occurring in the environment, such as anaerobic biodegradation process which releases methane and the use in the production of biogas. In this work, the development of low-volume gas flow rate measurement system using the method of pressure difference in a container of known volume is presented. A microcontroller is used to control two valves located one gas inlet and the other at the gas outlet of the container. Appropriate analysis of uncertainty propagation is carried out, and components suitable are selected for the development of the meter in order to perform the measurement with low uncertainty. Simulations and experimental tests are presented for validating the proposed system. / Os sistemas de medição de pequenas taxas de fluxo de gás tem grande relevância nos âmbitos industriais e científicos, nos quais suas aplicações exigem geralmente medições com baixa incerteza. Esses sistemas de medição tem tido uma grande evolução ultimamente. Isso se deve, principalmente, à preocupação com a liberação de gases em processos biológicos naturais como, por exemplo, o gás metano liberado no processo de biodegradação anaeróbio, e que também é aproveitado como biogás. Neste trabalho, apresenta-se o desenvolvimento de um medidor para pequenos volumes de gases utilizando o método de diferença de pressão em um recipiente de volume conhecido. Um microcontrolador é utilizado no controle das duas válvulas localizadas na entrada e na saída do recipiente. São realizados estudos apropriados de análise e propagação de incertezas, e são escolhidos componentes adequados para o desenvolvimento e construção do medidor, de modo a realizar a medição com boa exatidão e baixa incerteza. Simulações e testes experimentais são apresentados para validação do sistema proposto.
653

Uma abordagem computacional para a análise de sequências de DNA por meio dos códigos corretores de erros / A computational approach for the analysis of DNA sequences using error correcting codes

Pereira, Diogo Guilherme, 1981- 08 January 2014 (has links)
Orientador: Reginaldo Palazzo Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-26T03:06:58Z (GMT). No. of bitstreams: 1 Pereira_DiogoGuilherme_M.pdf: 2278721 bytes, checksum: d52e9ddea8e27d992073c5cf8ba3674f (MD5) Previous issue date: 2014 / Resumo: É evidente os benefícios proporcionados pela aplicação da teoria da informação nas análises dos processos de codificação genética. Este trabalho propõe o desenvolvimento de algoritmos, e sua implementação computacional, para a realização de análises em sequências de DNA por meio dos códigos BCH. O primeiro programa irá calcular diversos polinômios geradores que serão utilizados pelos outros programas. O segundo programa se utiliza destes polinômios geradores para realizar análises em sequências de DNA e identificar palavras-código na forma de novas sequências de DNA. Já o terceiro programa, de iniciativa inédita, se utiliza tanto dos polinômios geradores quanto as palavras-código e realiza um processo de decodificação com o intuito de rastrear as mutações passiveis de ocorrer em sequências de DNA / Abstract: The benefits provided by the application of information theory in the analyses of genetic coding processes are evident. In this work the development of algorithms and their computational implementations are proposed, with the aim at performing analyses of DNA sequences by use of BCH codes. The first program calculates several generator polynomials which are used by other programs. The second program uses generator polynomials to perform DNA sequence analyses and to identify the codewords in the form of new DNA sequences. The third program by using both the generator polynomials as well as the codewords to perform a decoding process in order to predict mutations that may occur in DNA sequences / Mestrado / Telecomunicações e Telemática / Mestre em Engenharia Elétrica
654

Estudos e simulações de filtro ativo paralelo para sistema trifásico com quatro fios usando estratégias de controle baseadas na modulação tridimensional por largura de pulsos com vetores espaciais / Study and simulation of a shunt active filter in a three-phase system with four-wire using control strategies based on the tridimensional space-vector pulse width modulation

Ota, João Inácio Yutaka 20 August 2018 (has links)
Orientadores: Ernesto Ruppert Filho; Marcelo Gradella Villalva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-20T00:11:08Z (GMT). No. of bitstreams: 1 Ota_JoaoInacioYutaka_M.pdf: 7717643 bytes, checksum: c0a1a3d8391b140cd3113fbbbc0106b8 (MD5) Previous issue date: 2011 / Resumo: Este trabalho apresenta um estudo sobre filtro ativo de potência paralelo para sistema trifásico com quatro fios, discutindo técnicas de compensação e de controle de correntes. O estudo concentra-se no filtro ativo paralelo composto por um inversor do tipo fonte de tensão com quatro pernas. Com esta estrutura de conversor são realizados estudos e simulações em computador de estratégias de compensação de correntes harmônicas e de controle de correntes. São investigadas técnicas de controle repetitivo, ressonante e proporcional-integral. Os sistemas de controle de correntes são construídos com um algoritmo de modulação por largura de pulsos tridimensional com vetores espaciais, que é investigado em detalhes no trabalho / Abstract: This dissertation presents a study of three-phase four-wire shunt active power filter, discussing compensation and control currents techniques. The study focuses on the shunt active filter composed by a four-leg voltage source inverter. Using this converter structure studies about strategies for compensation of harmonic currents and current control are carried out through computer simulations. Repetitive, resonant and proportional-integral control techniques are investigated. The current control system is performed using an algorithm of three-dimensional space-vector pulse width modulation, which is investigated in detail in the work / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
655

Sistema de alimentação chaveado para modulador de pulsos com linha de retardo aplicado em sistema radar = Switching mode system to supply pulse modulators based in pulse forming network applied to radar / Switching mode system to supply pulse modulators based in pulse forming network applied to radar

Dias, Agnaldo Vieira 21 August 2018 (has links)
Orientador: Ernesto Ruppert Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T00:56:13Z (GMT). No. of bitstreams: 1 Dias_AgnaldoVieira_M.pdf: 2229736 bytes, checksum: 725a7fa267bc30780c457689e4356336 (MD5) Previous issue date: 2012 / Resumo: O estudo da utilização de conversores CC/CC isolados e elevadores de tensão para a alimentação de moduladores de pulsos é apresentado neste trabalho. Foi selecionada a topologia em ponte completa, dando-se enfoque ao problema das capacitâncias parasitas envolvidas no circuito, que aparecem de forma acentuada em transformadores elevadores de tensão e filtros indutivos de saída e são altamente indesejáveis quando se opera em regime chaveado. Essas capacitâncias são tratadas através de uma forma de amortecimento, onde a energia armazenada nas mesmas é devolvida à fonte primária ao final de cada semiciclo de chaveamento, tentando obter-se menor volume, maior rendimento e menor dissipação de calor no conversor. Além disso, um circuito de regulação de carga é utilizado para garantir uma maior estabilidade de pulso e contornar problemas típicos de moduladores de pulsos utilizados em radares, como o efeito de backswing. O modulador de pulsos utilizado como carga para esse sistema opera com uma tensão de alimentação de 1kV, frequência de repetição de pulsos (PRF) de 585Hz e consome uma potência da ordem de 2,1kW. O conversor CC/CC é alimentado por um barramento CC não regulado de 280V / Abstract: The study of high-voltage isolated DC/DC converters used to supply pulse modulators is presented on this dissertation. The Full Bridge topology was selected, focusing in problems caused by parasitic capacitances in the circuit. This characteristic, which appears sharply in high voltage transformers and in inductors of output filter, is highly undesirable when the circuit is operated in switching mode. These capacitances are handled using a soft commutation technique, where their stored energy are returned to the primary source in the end of each switching cycle, trying to get a low size, high efficiency and low heat dissipation in the converter. Moreover, a charging regulator circuit is used to ensure good pulse stability and avoid typical problems in the pulse modulators use, such as the backswing effect. The pulse modulator used as load for this converter operates with a supply voltage of 1kV, pulse repetition frequency (PRF) of 585Hz and consumes 2.1 kW. The converter input is supplied by a 280V unregulated DC bus / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
656

Tratamento de chorume de aterro sanitario usando eletrolise foto-assistida / Treatment of landfill leachate by photo-assisted electrolysis

Moraes, Peterson Bueno de, 1972- 30 November 2004 (has links)
Orientador: Rodnei Bertazzoli / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T02:31:46Z (GMT). No. of bitstreams: 1 Moraes_PetersonBuenode_D.pdf: 7179386 bytes, checksum: 3f0a65f3012f62fac73e35450cdc9b40 (MD5) Previous issue date: 2004 / Resumo: Em aterros, quando o lixo depositado entra em decomposição, se forma o chorume, um líquido escuro e de odor desagradável, potencial patogênico e toxicológico que pode conter compostos orgânicos, metais pesados e outros íons e que se não adequadamente tratado pode causar problemas de caráter sanitário e ambiental. Métodos de oxidação química ou biológica habitualmente utilizados apresentam dificuldade para tratar chorume de aterros antigos. Visando a obtenção de um método de tratamento complementar ou alternativo, neste trabalho utilizou-se um sistema fotoeletroquímico em escala piloto de 18 L operando em modo contínuo com reciclo, composto por reator tubular com eletrodos comerciais ADE de Ti/70TiO2-30RuO2 e lâmpada ultravioleta para degradar chorume bruto de um aterro sanitário municipal. Esta configuração possui o diferencial de utilizar um sistema compacto, com eletrodo não-solúvel de longo tempo de vida útil e eliminar a necessidade de separação do semicondutor da solução após o tratamento. Foram comparados os processos fotocatalítico, eletrolítico e eletrolítico assistido por fotocatálise heterogênea com e sem a adição de fotocatalisador TiO2, determinando-se a eficiência do sistema por meio de análises de cor, DBO, DQO, toxicidade aguda, Carbono Orgânico Total, pH, temperatura, amônia e cloreto. O sistema foi otimizado em termos de densidade de corrente de eletrólise, tempo de tratamento e vazão da solução. Foram testados os valores 300, 1000,2000 e 3000 L h-1 nas densidades de corrente de 13,25, 39, 48, 78, 90 e 116 mA cm-2. No tratamento eletrolítico, em 180 min de processamento a 116,0 mA cm-2 e 2000 L h-1 foi possível remover de 86 a 1 00% da cor, 33 a 73% do COT, 31 a 90% da DQO e 31 a 100% da amônia do chorume. O comportamento cinético para remoção da cor, COT e DQO foi de segunda ordem, com constantes aparentes de velocidade de remoção variando entre 1,58.10-4 e 3,79.10-5 ma-1m s-1 2,13.10-8 e 2,92.10-9 m4s-1g-1 e 1,40.10-8 e 2,07.10-9 m4s-1g-l respectivamente. As remoções de amônia e cloreto seguiram comportamento cinético de primeira ordem, sendo que a constante média de velocidade de remoção de amônia variou entre 6,87.10-5 e 3,46.10-6 m s-1. Também, foram observadas reduções da DBO, da toxicidade e remoção de metais. Esta forma de tratamento não apresenta problemas posteriores em relação à geração de lodo ou subprodutos tóxicos, sendo indicada como complementar ao tratamento biológico / Abstract: Sanitary landfills are the major method used today for the disposal and management of municipal solid waste. Decomposition of waste and rainfall generate leachate at the bottom of landfills, causing groundwater contamination. The leachate is a dark grey, foul smelling solution and it can be considered a complex effluent, often containing organic compounds, heavy metals, and many other soluble compounds. Furthermore, leachate presents high values of biological oxygen demand (BOD), chemical oxygen demand (COD) and, because of its toxic potential, it may represent an environmental problem. Biological and chemica1 oxidation commonly used in the treatment have not entirely efficient in degrading old landfill leachate. Moreover, the process is sensitive to variable organic 10008 and different flow rates. In this study, leachate from an old age municipal landfill site was treated by photo-electrochemical oxidation in a pilot scale flow reactor (18 L), using DSA anode and UV radiation. The adopted system is small, compact, long service-life electrodes and separation between of cata1yst from solution is not necessary. By using photocatalytic, electrolytic and photo-assisted electrolytic processes, the effect of current density and flow rate on COD, BOD, total organic carbon, color, ammonia and toxicity removal was investigated. At a current density of 116.0 mA cm-l, flow rate of 2000 L h-1 and 180 min of processing, removal of 86-100% of color, 33-73% of TOC, 31-90% of COD and 31-100% of ammonia were achieved. Removal rates for color, TOC and COD presented a second-order kinetic, with apparent kinetic constants among 1,58.10-4 - 3,79.10-5 ma-lm s-l, 2,13.10-8 - 2,92.10-9 m4s-1g-1 and 1,40.10-8 - 2,07.10-9 m4s-1g-1 respectively. The ammonia and chloride removal followed a first-order kinetic, with apparent kinetic constants ranging from 6,87.10-5 to 3,46.10-6 m s-1. Furthermore, BOD, toxicity and metallic ions were also removed. This process of treatment doesn't show further problems related to sludge production or toxic by-products, been appointed as complementary to traditional biological systems. Besides the high energy consumption, the process proved effectiveness in degrading leachate, despite this effluent' s usual refractoriness to treatment / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
657

[en] DIGITAL MICROSCOPY APPLIED TO THE QUANTIFICATION OF THE EFFECT OF CHELATORS ON DENTINE / [pt] APLICAÇÃO DA MICROSCOPIA DIGITAL NA QUANTIFICAÇÃO DO EFEITO DE QUELANTES EM DENTINA

CLAUDIA MENDONCA REIS 06 March 2007 (has links)
[pt] Após instrumentação do canal radicular, uma camada de material orgânico/inorgânico é formada sobre a dentina. Não existe um consenso sobre o método ideal para a remoção deste smear layer e exposição dos túbulos dentinários, necessários à adaptação da obturação ao canal radicular. Geralmente, soluções quelantes são utilizadas com essa finalidade, mas a substância e o tempo ideais permanecem desconhecidos. Nesse estudo, foi analisado o poder quelante de EDTA, EDTAC e ácido cítrico (AC) 1%, 5% e 10% sobre dentina radicular. Através de microscopia óptica co-localizada foram capturadas imagens de vários campos de cada amostra, em 5 diferentes tempos de ataque ácido (15 a 300 s). Uma seqüência de processamento e análise de imagens foi utilizada para medir dezenas de imagens, obtendo dados relativos à fração de área ocupada e de tamanho de milhares de túbulos ao longo do tempo. Assim, foi possível acompanhar a evolução do processo e quantificar o efeito das substâncias. As soluções de AC apresentaram maior poder quelante. EDTA e AC 1% apresentaram efeitos similares após 300 s. O EDTAC teve o menor efeito. Experimentos análogos com microscopia eletrônica de varredura ambiental forneceram resultados similares, com maior informação sobre a rugosidade da superfície dentinária. AC 10% causou erosão severa após 60 s. / [en] Instrumentation methods currently used in endodontic therapy create a residual layer composed of organic and inorganic material. There is no universal consensus regarding the ideal method for removing this smear layer and exposing the dentinary tubules, necessary for the adaptation of root canal filling. In general, chelating solutions are used but the ideal solution and application time remain unknown. In the present study the chelating power of EDTA, EDTAC and 1, 5 and 10% citric acid (CA) on radicular dentine was analyzed. Co-site digital optical microscopy was used to capture images of several fields of each sample after acid etching for 5 experimental times (15-300 s). An image processing and analysis sequence measured tens of images, providing data of area fraction and size for thousands of tubules over time. Thus, it was possible to follow the phenomenon and quantitatively analyze the effect of the various substances. The CA solutions showed the greatest chelating power. EDTA and CA 1% showed similar effect after 300 s. EDTAC was the least effective. Equivalent experiments employing Environmental Scanning Electron Microscopy provided similar results, complemented by a better view of dentine surface roughness. CA 10% caused severe erosion of the surface
658

Combinador eletro-optico para geração de sinais pulsados ultra-rapidos de microondas / Electrooptic combinator for ultra-fast pulsed microwave signal generation

Castelli, Claudio Selmi 16 January 2007 (has links)
Orientador: Evandro Conforti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-08T01:55:52Z (GMT). No. of bitstreams: 1 Castelli_ClaudioSelmi_M.pdf: 2856453 bytes, checksum: 1efb001a79f5f2d885e231abadd78d1f (MD5) Previous issue date: 2007 / Resumo: Uma nova técnica de geração de sinais pulsados de microondas é desenvolvida. Baseia-se na composição de dois sinais arbitrários, um trem de pulsos ultra-rápidos e uma portadora de microondas, originados a partir de diferentes fontes e combinados no domínio óptico de forma a preservar ao máximo as características espectrais e temporais dos sinais. São apresentados os conceitos utilizados na técnica e toda a configuração empregada na sua validação experimental. Os resultados obtidos são discutidos e comparados com os sinais pulsados de microondas gerados a partir de um moderno gerador comercial. Os principais componentes utilizados são também caracterizados e propostas de melhorias são apresentadas. A forma de onda obtida a partir da técnica desenvolvida atingiu os resultados esperados / Abstract: A novel technique of pulsed microwave waveform generation has been developed. It is based on the mixture of two arbitrary signals, an ultra-fast pulse train and a microwave carrier, all generated from different sources and combined in the optical domain in order to preserve the spectral and temporal features as much as possible. The technique's concepts and the setup used for the experimental validation have been presented. The obtained results are discussed and compared to the pulsed microwave signals generated by a modern commercial microwave generator. The main components are also characterized and proposals of improvements have been presented. The waveform resulted from this developed technique reached the expected results / Mestrado / Telecomunicações e Telemática / Mestre em Engenharia Elétrica
659

Desenvolvimento de uma antena quadribanda GSM integrada / Design of a quadband integrated GSM antenna

Moraes, Murilo Oliveira de 22 August 2018 (has links)
Orientador: Hugo Enrique Hernandez Figueroa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-22T03:58:50Z (GMT). No. of bitstreams: 1 Moraes_MuriloOliveirade_M.pdf: 26552033 bytes, checksum: 9a9022f8aa6d5e4e72047f0798ad57da (MD5) Previous issue date: 2013 / Resumo: A complexidade dos sistemas eletrônicos atuais cria a demanda por mais componentes num mesmo sistema, ao mesmo tempo em que exige sistemas mais compactos. Esta dissertação apresenta o desenvolvimento, fabricação e testes de uma antena GSM quadribanda, integrada a um módulo rastreador automotivo produzido no mercado nacional. A antena opera dentro das faixas de freqüências correspondentes _as bandas GSM 850/900/1800/1900, com desempenho adequado para uso no sistema de comunicação GSM, estando em conformidade com testes de TRP, sendo o produto final homologado pela ANATEL e agências reguladoras de outros países. A antena é um monopolo com dobras especiais para ajuste de ressonância. O casamento da antena com o sistema _e realizado via um toco em curto dobrado, não trivial, otimizado para um casamento banda-larga ao longo do espectro GSM ocupado / Abstract: The complexity of today's electronic systems creates demand for more quantity and less cost of components in a system, at the same time that the system must be made smaller. This dissertation presents the design and tests of a quadband GSM antenna, embedded into an existing automotive tracking module produced in Brazil. The antenna operates within the GSM 850/900/1800/1900 bands, with performance suitable for its use in the GSM system, being in conformance with TRP tests. The final product is approved by Brazil's regulatory agency ANATEL and by other countries' agencies. The antenna is a monopole with special bandings for resonance adjustment. The antenna matching is achieved with a shorted bent stub, non-trivial, optimized for a broadband matching over the occupied GSM spectrum / Mestrado / Telecomunicações e Telemática / Mestre em Engenharia Elétrica
660

Contribuição ao estudo do sensor de umidade do solo que utiliza a técnica de dissipação de calor baseado em um transistor de junção bipolar (NPN) / Contribution to the study of soil moisture sensor utilizing the technique of heat dissipation based a npn bipolar junction transistor

Roque, Wellington 22 August 2018 (has links)
Orientador: José Antonio Siqueira Dias / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-22T06:29:21Z (GMT). No. of bitstreams: 1 Roque_Wellington_D.pdf: 36135434 bytes, checksum: 2e9ca0be59b1286da36d45ebc67dfd0d (MD5) Previous issue date: 2012 / Resumo: A aplicação de sensores de umidade do solo vem aumentando devido à necessidade do uso eficiente da água para irrigação. Uma das técnicas amplamente utilizadas para o desenvolvimento desses sensores é a de dissipação de calor. Nesta técnica, um elemento aquecedor é usado para aplicar um pulso de calor no solo, gerando um aumento de temperatura, o qual é mensurado e relacionado com a umidade do solo. Porém, um dos principais problemas desse tipo de sensor é sua baixa sensibilidade. Buscando resolver esse problema, foi desenvolvido um sensor que utiliza um transistor bipolar como único elemento aquecedor e transdutor de temperatura. Uma energia aplicada causa aquecimento no transistor e consequentemente provoca uma variação na tensão da junção base-emissor. Com isso, realizamos um estudo, a fim de determinar qual o valor ideal de energia aplicada que proporcionaria a máxima sensibilidade na medida da variação da temperatura. Para isso foram utilizados para fabricação dos sensores 16 transistores com encapsulamento metálico (TO - 18). Os sensores foram inseridos em amostras de solo deformadas, que foram saturadas para realização da medida da umidade do solo, através do método gravimétrico. Foram realizados com cada sensor curvas de calibração relacionando a umidade do solo com a com o valor de ?T, para os diferentes valores de energias fornecidos no sensor. Após análise dos dados, foram escolhidos dois sensores que apresentaram maior variação entre suas curvas de calibração para serem inseridos em uma solução de Agar Agar e no Ar, realizando várias medidas nos sensores, sempre com os mesmos valores de energia, para verificar a repetibilidade dos mesmos. Os resultados mostraram que, em relação à energia aplicada no sensor, àquela que proporcionou uma maior sensibilidade em função da umidade do solo foi de 1:5J (25 V, 6,3 mA, 10 s). Foi constatado que a sensibilidade do sensor melhora com o aumento da potência, sendo que esta melhora é relativamente independente da energia fornecida. Em relação às medidas realizadas no Agar Agar, observamos uma melhora considerável do erro em função das medidas realizadas no solo, de 10% para o solo, para 4% no Agar Agar. Para as medidas realizadas no Ar, o valor do erro diminui para 1%. Para as medidas realizadas no solo, na solução de Agar Agar e no Ar, chegamos à conclusão que a diminuição do erro das medidas realizadas em cada um deles, ocorre devido à mudança do contato do sensor com o solo durante as medidas, visto que o solo, quando começa perder umidade ele altera o seu volume, levando a uma diminuição da superfície de contato do mesmo com o sensor. Esse erro pode ser também em função da variação da densidade do solo que ocorre durante a realização dos ensaios, causando uma diferença no valor das medidas, já citadas em outras literaturas. Observamos também que para a melhor utilização do sensor em diferentes faixas de umidade do solo, há a necessidade de alterar a energia aplicada, devido à sensibilidade de o sensor ser maior para umidades mais baixas (abaixo de 30%), necessitando de um acréscimo do valor da energia aplicada para se obter uma melhor sensibilidade para umidades altas (acima de 30%) / Abstract: The use of soil moisture sensors is increasing due to the need for efficient use of water for irrigation. One technique widely used for the development of these sensors is the heat dissipation. In this technique, a heater element is used for applying a pulse of heat into the soil, causing a rise in temperature, which is measured and related to the soil moisture. However, a major problem of this type of sensor is its low sensitivity. To solve this problem, we developed a sensor that uses a bipolar transistor as a single element heater and temperature transducer. Energy applied to the transistor causes its heating, which in turn causes a variation on the voltage of the base-emitter junction. So we conducted a study to determine the optimal value of energy applied to provide maximum sensitivity in the measurement of temperature variation. To do this, 16 metal case TO-18 package transistors were used in the fabrication of the sensors. The sensors were inserted in deformed soil samples, which were water-saturated to perform the measurement of soil moisture using the gravimetric method. With each sensor we obtained calibration curves relating the soil moisture to the value of temperature for the different values of energy supplied to the sensor. After analyzing the data, two sensors that showed greater temperature variation in their calibration curves were chosen to be inserted into a solution of Agar Agar and in the air, in order to perform multiple measurements with the sensors at the same energy values to check their repeatability. The results showed that the energy which provided a greater sensitivity as a function of soil moisture was 1,5 J (25 V, 6,3 mA 10 s). We have found that the sensor sensitivity improves with increasing dissipated power and this improvement is relatively independent of the energy supplied. Regarding the measurements performed in Agar Agar, we observed a significantly lower error compared to the measurements taken in the soil: from 10% for the soil measurements to 4% in the Agar Agar. For the measurements made in air, the error decreased to 1%. For the measurements made in soil, in solution of Agar Agar and in air, we concluded that the decrease of the measurements errors performed in each of them occurs due to a changing in the contact between the sensor and the media during the measurements, because the soil changes its volume when it begins to lose moisture, leading to a decreased surface contact with the sensor. This error can also be due to the variation of soil density that occurs during the tests. We also observed that for the best use of this sensor in different ranges of soil moisture there is a need to change the applied power due to the higher sensitivity of the sensor for moisture content below 30%, needing an increase in the amount of this power to obtain a better sensitivity to humidity above 30% / Doutorado / Eletrônica, Microeletrônica e Optoeletrônica / Doutor em Engenharia Elétrica

Page generated in 0.2509 seconds