Spelling suggestions: "subject:"emissões"" "subject:"missões""
11 |
Health monitoring of FRP using acoustic emission and fibre optic techniquesOliveira, Rui Fernando da Costa January 2004 (has links)
Tese de doutoramento. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto, Université du Maine. 2004
|
12 |
Avaliação do dano gerado pelo ruído nas células ciliadas externas de professores do ensino fundamental de uma regional de ensino do Distrito FederalNovanta, Gabriela Guenther Ribeiro January 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências Médicas, Programa de Pós-Graduação em Ciências Médicas, 2015. / Submitted by Cristiane Mendes (mcristianem@gmail.com) on 2015-07-01T13:31:28Z
No. of bitstreams: 1
2015_GabrielaGuentherRibeiroNovanta.pdf: 1104044 bytes, checksum: 4620c6c3837e965c9c48dde66a920791 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2015-07-02T15:02:26Z (GMT) No. of bitstreams: 1
2015_GabrielaGuentherRibeiroNovanta.pdf: 1104044 bytes, checksum: 4620c6c3837e965c9c48dde66a920791 (MD5) / Made available in DSpace on 2015-07-02T15:02:26Z (GMT). No. of bitstreams: 1
2015_GabrielaGuentherRibeiroNovanta.pdf: 1104044 bytes, checksum: 4620c6c3837e965c9c48dde66a920791 (MD5) / Introdução: O excesso de ruído presente nas escolas tem sido uma queixa frequentemente referida pela categoria dos professores. Embora a Associação Brasileira de Normas Técnicas (ABNT) estabeleça que o ruído dentro da sala de aula deve atingir no máximo 50dB (1), diversos estudos realizados no Brasil citam intensidades próximas ou superiores a 70 dB dentro das salas de aula. Este excesso de ruído poderá provocar reações psicológicas, fisiológicas e patológicas na saúde dos professores, e principalmente, prejudicar a audição. Objetivos: Avaliar do dano gerado pelo ruído nas células ciliadas externas de professores do ensino fundamental de uma regional de ensino do Distrito Federal. Métodos: Foram realizados os testes de emissões otoacústicas transientes (EOAT) e emissões otoacústicas por produto de distorção (EOAPD) com repouso acústico e o teste de EOAPD após a jornada de trabalho. Para a análise das EOAT e EOAPD foi utilizado o critério "passa/falha", por meio da avaliação da amplitude da resposta e da relação sinal/ruído. Durante o período de aula, foram realizadas medições dos níveis de pressão sonora dentro das salas de aula, por meio de um decibelímetro. Foram realizadas medições de 10 minutos, e registrados o LAeq (nível de pressão sonora equivalente), o valor mínimo e o valor máximo. Resultados: Foram avaliados 67 professores com idades entre 21 e 54 anos (Média 37,1; DP 8,4) dos quais 61 do sexo feminino (91%) e 6 do sexo masculino (9%). O tempo de magistério variou entre 1 e 27 anos (Média 10,7; DP 6,8). Foram realizadas 210 medições dos níveis de pressão sonora, sendo três registros para cada uma das 67 salas de aula. A média do ruído (LAeq) foi de 76,6 dB (A) (DP 5,4), a mínima foi de 59,2 dB (A) (DP 4,3) e a máxima foi de 90,2 dB (A) (DP 7,1). Pelo critério “passa/falha”, apenas 34,3% dos professores apresentou "passa" ou normal nas EOAT em ambas as orelhas e 16,4% dos professores apresentou "passa" ou normal nas EOAPD para ambas as orelhas. Na comparação entre os dois momentos (com repouso auditivo e após exposição da jornada de trabalho) das EOAPD, foi encontrada uma diminuição significante na amplitude da resposta e na relação sinal/ruído na segunda avaliação para as frequências de 2 e 4 kHz. O aumento dos níveis de ruído esteve relacionado com a diminuição da amplitude da resposta nas frequências de 2 e 4 kHz e com a relação sinal/ruído na frequência de 4 kHz. Conclusão: O ruído presente dentro da sala de aula foi capaz de gerar uma alteração na função das células ciliadas externas dos professores avaliados. Foi encontrada uma alta prevalência de resultados alterados mesmo com repouso auditivo, que sugere uma relação entre a exposição ao ruído e o dano auditivo. / Introduction: The excessive noise present in schools has been a frequent complaint reported by teachers’. Although the Brazilian Association of Technical Standards (ABNT) has established that noise inside classrooms should not exceed 50 dB, several studies conducted in Brazil have mentioned intensities close to or higher than 70 dB in classrooms. This excess of noise may cause psychological, physiological and pathological reactions in the health of teachers, especially damage to hearing. Objectives: To evaluate the damage generated by noise in outer hair cells of elementary school teachers of one of the Federal District´s area. Methods: otoacoustic emission tests (EOAT) and otoacoustic emissions by distortion product (DPOAE) were performed with acoustic rest and the DPOAE test after a day of work. For the analysis of TEOAE and DPOAE the "pass / fail" criteria was used, through the evaluation of the amplitude response and signal / noise ratio. During teaching classes, measurements were made on sound pressure levels in classrooms through a decibel meter. Ten-minute measurements were performed, and registered at the LAeq (equivalent sound pressure level), the minimum value and the maximum value. Results: A total of 67 teachers aged between 21 to 54 years (average 37.1, SD 8.4) from which 61 were females (91%) and 6 males (9%). Their teaching experience ranged from 1 to 27 years (average 10.7, SD 6.8). 210 measurements of sound pressure levels were conducted, being three records for each of the 67 classrooms. The noise average (LAeq) was 76.6 dB (A) (SD 5.4), the lowest was 59.2 dB (A) (SD 4.3) and the highest was 90.2 dB (A) (SD 7.1). Through "pass / fail" criteria, only 34.3% of teachers were considered "pass" or normal in TEOAE in both ears and 16.4% of teachers were considered "pass" or normal in DPOAE in both ears. Comparing the two time points (with auditory rest and after exposure of the day of work) DPOAE, we found a significant decrease in response amplitude and signal / noise ratio in the second evaluation for the frequencies of 2 and 4 kHz. The increase in noise levels was related to the decrease in amplitude response for 2 and 4 kHz frequency and the signal / noise ratio in 4 kHz frequency. Conclusion: The noise inside classrooms was capable to generate a change in the function of the outer hair cells of the evaluated teachers. A high prevalence of abnormal results was found even with hearing rest, which suggests a relation between noise exposure and hearing damage.
|
13 |
Suspended particles in outdoor and indoor air : characterization to support epidemiological studiesSlezáková, Klára January 2009 (has links)
Tese de doutoramento. Ciências de Engenharia. Faculdade de Engenharia. Universidade do Porto. 2009
|
14 |
Avaliação técnico-econômica da implementação de um sistema de cultivo de microalgas na usina termelétrica Barbosa Lima Sobrinho com vista à biofixação de CO2 / Technical-economic evaluation of implementing a system of cultivation of microalgae on power plant Barbosa Lima Sobrinho for the CO2 biofixationFelipe Augusto Pereira Dias 30 March 2011 (has links)
Este estudo teve como finalidade levantar dados para uma avaliação das alternativas tecnológicas (cultivos de microalgas e reflorestamento) para a biofixação de CO2 da atmosfera próxima à usina termelétrica; tendo sido utilizada como referência a Usina Barbosa Lima Sobrinho. Já existe um projeto de avaliação do efeito do reflorestamento na fixação do CO2 nesta usina e, neste trabalho, foi avaliada a alternativa do cultivo de microalgas.
Uma pesquisa inicial foi feita na literatura para verificar qual a espécie de microalga seria a mais adequada para ser utilizada no estudo, tendo sido a espécie Chlorella sp. a selecionada. Posteriormente os sistemas de cultivo de microalgas mais comumente empregados no mercado foram levantados e foi selecionado o cultivo em tanques abertos como referência para a modelagem do processo. Utilizando os dados da termelétrica e da literatura foi possível estimar a quantidade de CO2 que será retirada da atmosfera caso um sistema de cultivo seja efetivamente instalado na usina termelétrica. Uma análise econômica foi realizada para determinar a viabilidade do projeto. Os resultados indicam que a utilização deste tipo de tecnologia é promissora / This study aimed to collect data for an evaluation of alternative technologies (microalgae cultivations and reforestation) for biofixation of CO2 from the atmosphere near a power plant, named Barbosa Lima Sobrinho, which uses natural gas and diesel as fuels. There is a project to assess the effect of reforestation for CO2 fixation in this facility and, in this study, we evaluated the alternative of cultivating microalgae. An initial review was done in the literature to determine what species of microalgae would be most suitable to use and Chlorella sp was selected. Thereafter cultivation of microalgae media, commonly employed in the market, were evaluated and the culture selected was in open tanks as a reference for the modeling process. Using data from the thermoelectric and the literature it was possible to estimate the amount of CO2 that will be capture from the atmosphere if a microalgae farming will be installed in thermal power plant area. An economic analysis was performed to determine the feasibility of the project. The results indicate that the use of this technology is promising
|
15 |
Estudo das emissões gasosas por processos de desodorizaçãoSousa, Vera Mónica Almeida de January 2009 (has links)
Estágio realizado na EFACEC Ambiente, S. A. e orientado pelo Eng.ª Amélia Fonseca / Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2009
|
16 |
Potencial de redução de emissões de CO2 em empresas do grupo Soares da CostaRodrigues, Maria Helena Gonçalves Ribeiro January 2010 (has links)
Estágio realizado na Empesa Grupo Soares da Costa SGPS, SA e orientado pela Engª Eloísa Isabel Fernandes Cepinha / Tese de mestrado integrado. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 2010
|
17 |
Previsão a curto e médio prazo de preços em mercado de carbonoLopes, Filipe Manuel de Almeida January 2010 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores (Major Energia). Faculdade de Engenharia. Universidade do Porto. 2010
|
18 |
Quantificação da pegada de carbono da empresa Vestas PortugalEstrela, Diogo Alves January 2010 (has links)
Tese de mestrado integrado. Engenharia do Ambiente. Ramo de Gestão. Faculdade de Engenharia. Universidade do Porto. 2011
|
19 |
Afectação adequada de recursos no sector do transporte rodoviário de passageirosBelindro, Diogo Manuel Montenegro January 2010 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2010
|
20 |
Estudo e análise do sistema de arranque e paragem automática do motor no automóvelMarques, Carlos Filipe de Freitas January 2009 (has links)
Estágio realizado no Centro Técnico da SEAT e orientado pelo Eng.º Ignácio Castilla / Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2009
|
Page generated in 0.038 seconds