• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 3
  • 1
  • Tagged with
  • 13
  • 6
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

La compétition de flux comme facteur prédictif de la perméabilité des branches artérielles collatérales après mise en place des stents de diversion de flux dans les artères intracrâniennes / Flow competition as a factor of patency of side/collateral arterial branches after deployment of flow diverting stents in intracranial arteries

Iosif, Christina 08 February 2016 (has links)
Le devenir des branches artérielles émergentes de la proximité d’un anévrysme intracrânien et couvertes par un stent à diversion de flux lors le traitement de l’anévrysme reste controversé. Une recherche animalière de caractère translationnel a été conduite afin d’élucider le rôle du flux collatéral dans les changements hémodynamiques apportés par un stent a diversion de flux. La couverture néointimale relative aux modifications hémodynamiques aux ostia de ces artères a été également évaluée. Pour atteindre notre objectif, nous avons cherché à quantifier les changements hémodynamiques dans les artères couvertes à leurs origines et à quantifier leur surface de couverture par le tissu endothélial à 3 mois après le placement du stent à diversion de flux dans un modèle animal porcin.Méthodes Suivant une analyse de pouvoir statistique a priori, deux groupes (A, B), chacun contenant sept porcs de race large white, ont été créés, suivant un modèle de flux de circulation artérielle terminale ou anastomotique. Groupe A correspondait à une configuration artérielle de type anastomotique pour l’artère Pharyngienne ascendante droite et groupe B à une configuration terminale concernant la même branche ; cette configuration terminale a été créée par l’occlusion endovasculaire sélective des apports artériels collatéraux pour le territoire de suppléance de l’artère Pharyngienne ascendante droite. Ensuite, pour chacun des 14 animaux, un stent à diversion de flux a été placé dans la carotide interne droite couvrant ainsi l’ostium de l’artère pharyngienne ascendante homolatérale. Pour mesurer les vélocités à l’origine de cette artère, une séquence IRM de contraste de phase tridimensionnelle avec une résolution temporelle (4D) a été utilisée. Des valeurs ont été obtenues avant et après stenting. Trois mois plus tard, un travail de prélèvement anatomique suivi d’une analyse par microscopie à balayage anatomique a été a été réalisé. Une quantification surfacique a été ainsi obtenue permettant de déterminer la perméabilité des ostia des artères pharyngienne ascendante. Les données ont été ainsi analysées grâce à des tests de statistique descriptive et comparative des deux groupes prédéterminés. Des tests paramétriques et non paramétriques ont également été obtenus. Résultats La faisabilité a pu être obtenue dans tous les spécimens utilisés. Nous n’avons déploré aucune mortalité immédiate ni aucune occlusion intra-stent relatives à la procédure. Les séquences IRM de diffusion ont témoigné de l’absence d’ischémie distale à la phase aigue après la mise en place du stent, Immédiatement, en post stenting, le flux moyen dans les artères pharyngiennes ascendantes droites du groupe a été réduit d’une façon significative, quand on le compare à la valeur moyenne en pré- stenting [P = 0.0008, pouvoir statistique: 0.9548]. Au contraire, le flux moyen dans les artères pharyngiennes ascendantes droites du groupe B est resté comparable à la valeur moyenne pré- stenting. Apres trois mois de suivi, la valeur moyenne de surface perméable était significativement plus élevée dans le groupe B (527,911 ± 306,229 μm2) que dans le groupe A (89,329 ± 59,762 μm2) [P< 0.01, power: 1.00], malgré la similarité les dimensions artérielles initiales (pré-stenting) dans les deux groupes. Une corrélation positive significative a été retrouvée entre les deux groupes concernant le flux moyen post stenting et la surface moyenne de couverture aux ostia, à trois mois de suivi. / The outcome of jailing arterial branches that emerge near intracranial aneurysms during flow-diverting stent deployment remains controversial. We report an animal research study aiming to elucidate the role of collateral supply in the hemodynamic changes and neointimal modifications resulting from jailing arteries with flow-diverting stents. To serve this purpose, we sought to quantify the hemodynamic changes at the jailed arterial branches immediately after stenting, as well as quantify the ostia surface values at three months post-stenting, in the presence or absence of collateral arterial flow. Methods After a priori power analysis, two groups (A, B), each containing seven large white swine, were created according to an animal flow model for terminal and anastomotic arterial circulation. Group A corresponded to an arterial configuration with anastomotic type of arterial supply for the territory of the right Ascending Pharyngeal artery (APhA) and group B to an arterial configuration of terminal type of arterial supply for the territory of the right APhA. Subsequently, all animals were stented by flow-diverting stents, jailing the right ascending pharyngeal arteries. Mean flow rates and velocities inside the jailed branches were quantified before and after stenting by time-resolved, 3D, phase contrast MRA. After three months the jailed ostia surface values were quantified on scanning electron microscopic images. The data were analyzed using descriptive statistics and group comparisons with parametric and non-parametric tests.Results Endovascular procedures were feasible, without in situ thrombus formation or ischemic DWI findings on post-procedure MRIs. Immediately following stenting, mean flow rate values at the jailed right ascending pharyngeal arteries were reduced in group A, as compared to the pre-stenting values [P = 0.0008, power: 0.9548]. In contrast, mean flow rates for group B remained similar to the pre-stenting values. At three months post-stenting, mean ostia surface values were significantly higher for group B (527,911 ± 306,229 μm2) than for group A (89,329 ± 59,762 μm2) [P< 0.01, power: 1.00], even though the initial dimensions of the jailed ostia were similar between groups. A statistically significant correlation was found between group (A or B), mean flow rates post-stenting and ostia surface values at three months. ConclusionWhen important collateral supply was present, jailing side arteries with flow-diverters resulted in an immediate, significant reduction in flow rate inside these arteries, as compared to the pre-stenting values. In contrast, when competitive flow was absent, jailing did not result in significant flow rate reductions inside the jailed arteries. Ostium surface values at three months were significantly higher in the terminal group of jailed arteries, compared to the anastomotic group and strongly correlated with the velocity value reductions post- stenting. Key words: flow-diverting stent, collateral arteries, endothelialization, ostium, embolization, magnetic resonance angiography, magnetic resonance imaging
12

Polydopamine-mediated long-term elution of the direct thrombin inhibitor bivalirudin from TiO₂ nanotubes for improved vascular biocompatibility

Yang, Zhilu, Zhong, Si, Yang, Ying, Maitz, Manfred F., Li, Xiangyang, Tu, Qiufen, Qi, Pengkai, Zhang, Heng, Qiu, Hua, Wan, Jin, Huang, Nan 07 January 2020 (has links)
Thrombosis and restenosis are two major complications associated with current commercial vascular stents. In situ regeneration of a healthy endothelium has been recognized as a promising strategy to address these issues. Numerous strategies have been explored for this goal. However, in most of the cases, they only focused on enhancing endothelial cell growth, ignoring antithrombotic requirements and the competition between smooth muscle cells (SMCs) and endothelial cells (ECs) for their growth. This resulted in non-satisfying clinical results. In this study, we created a multifunctional surface that meets the need of antithrombosis and re-endothelialization. A nanotubular titanium oxide (TiO₂) system has been developed, which elutes the direct thrombin inhibitor, bivalirudin (BVLD); moreover, polydopamine (PDAM) is used to tailor the surface functionality of TiO₂ nanotubes (NTs) for controlling the elution of BVLD. PDAM-functionalized TiO₂ NTs controls the BVLD for more than two months. BVLD eluted from NTs was bioactive and showed a substantial inhibitory effect on thrombin bioactivity, platelet adhesion and activation. In addition, the BVLD-eluting nanotubular TiO₂ system has high selectivity to enhance human umbilical vein endothelial cell (HUVEC) growth, while it inhibits human umbilical artery smooth muscle cell (HUASMC) proliferation. Our design strategy for the BVLD-eluting nanotubular TiO₂ system creates a favorable microenvironment for durable thromboresistance and the promotion of reendothelialization, and thus it is suitable for the long-term treatment of cardiovascular diseases.
13

Ενδοαγγειακή απεικόνιση των αγγείων κάτωθεν του βουβωνικού συνδέσμου με Οπτική Συνεκτική Τομογραφία (Optical Coherence Tomography)

Παρασκευόπουλος, Ιωάννης 18 June 2014 (has links)
Η οπτική συνεκτική τομογραφία με τη χρήση συχνοτήτων ( FD-OCT) είναι μια ενδαγγειακή απεικονιστική μέθοδος που χρησιμοποιεί εγγύς στο υπέρυθρο φως, για να παράγει υψηλής ανάλυσης εικόνες του τοιχώματος του αυλού του αγγείου. Όπως και στην τεχνολογία υπερήχων, εκπέμπεται φωτεινή ενέργεια η οποία ανακλάται και εξασθενεί, σύμφωνα με την υφή του προσπιπτομένου ιστού. Το OCT μπορεί να απεικονίσει, με ανάλυση από 10 έως 20 μm, μικροδομές του αγγειακού τοιχώματος με εξαίσια λεπτομέρεια. Μέχρι σήμερα, η δυνατότητα εφαρμογής της μεθόδου είχε περιοριστεί σε μικρές αρτηρίες διαμέτρου έως 4mm και δεν είχε εφαρμοστεί in vivo στα αγγεία των κάτω άκρων, κάτωθεν του επιπέδου των βουβώνων. Σκοπός της παρούσας μελέτης είναι να αναφερθεί για παγκοσμίως πρώτη φορά η ασφάλεια και η σκοπιμότητα της απεικόνισης με Οπτική Συνεκτική Τομογραφία του αρτηριακού άξονα των κάτω άκρων , κάτωθεν του επιπέδου της βουβώνας ( μηροϊγνυακός άξονας και κνημιαία αγγεία), καθώς και οι σχετιζόμενες με το FD-OCT επιπλοκές. Επιπρόσθετα, να διερευνηθούν για πρώτη φορά, με τη χρήση FD-OCT, τα χαρακτηριστικά του αγγειακού τοιχώματος του ανωτέρω άξονα (τόσο πριν όσο και μετά από αγγειοπλαστική ή/και τοποθέτηση stent), η μορφολογία της αθηρωματικής πλάκας, η μορφολογία και η ποσοτικοποίηση της υπερπλασίας του νέου εσωτερικού χιτώνα (neointima) εντός του stent, η επαναστένωση εντός του stent (ISR) και η κακή εναπόθεση (malapposition) των stent struts σε μια σειρά από ασθενείς που πάσχουν από περιφερική αρτηριοπάθεια (PAD). Μελετήθηκαν, με ποσοτική ανάλυση του αυλού τους (Quantitative vascular analysis), αρτηρίες με διάμετρο έως 7 χιλιοστά. Μικτά χαρακτηριστικά από περιοχές πλούσιες σε λιπίδια, εναποθέσεις ασβεστίου και ασβεστοποιημένες πλάκες, νεκρωτικές περιοχές και ίνωση εντοπίστηκαν σε όλες τις απεικονιζόμενες αθηροσκληρωτικές βλάβες. Ωστόσο, με βάση το επικρατέστερο από τα παραπάνω απεικονιστικά χαρακτηριστικά, οι βλάβες στο πλαίσιο της έρευνας ταξινομήθηκαν ως αμιγώς ινωτικές, ως ινοασβεστοποιημένες, ως πλούσιες σε λιπίδια και τέλος ως νεκρωτικές/ασβεστοποιημένες. Συσσώρευση των μακροφάγων εντός της αθηρωματικής πλάκας σημειώθηκε σε μικρό ποσοστό των de novo αθηρωματικών αλλοιώσεων. Ποικίλοι βαθμοί υπερπλασίας του νέου έσω χιτώνα απεικονίσθηκαν σε όλες τις περιπτώσεις ISR αλλοιώσεων, με καθαρά ινωτικά χαρακτηριστικά και σημαντική νεοαγγείωση σε κάποιες από αυτές. Η νεοαγγείωση συνέπεσε με το επίπεδο της μέγιστης στένωσης του αγγειακού αυλού. Σημαντικού βαθμού διαχωρισμός με μεγάλο περιορισμό του αγγειακού αυλού, τέτοιος ώστε να απαιτηθεί να τοποθετηθεί ενδοαυλικό stent, ανιχνεύθηκε σε αρκετές περιπτώσεις της de novo αθηρωμάτωσης. Η ψηφιακή αφαιρετική αγγειογραφία παρέλειψε να προσδιορίσει μεγάλο ποσοστό των σοβαρών διαχωρισμών μετά από αγγειοπλαστική. Η νεοαθηροσκλήρυνση εντός του νέου έσω χιτώνα των κνημιαίων φαρμακευτικών stents (DES), είναι ένα συχνό εύρημα τόσο στους συμπτωματικούς όσο και στους ασυμπτωματικούς ασθενείς. Μπορούμε να υποθέσουμε ότι, κατά αναλογία με τα εμφυτευμένα DES στα στεφανιαία αγγεία, η ελαττωματική ενδοθηλιοποίηση που προκαλείται από την εκλυόμενη φαρμακευτική ουσία, μαζί με την νεοαγγείωση που αναπτύσσεται μεταξύ των stent struts, μπορούν να υποδαυλίσουν την νεοαθηροσκλήρυνση εντός του νέου έσω χιτώνα των κνημιαίων DES, η οποία μπορεί να οδηγήσει σε επαναστένωση εντός του stent (ISR) και απώλεια του εμβαδού του αυλού των περιφερικών αρτηριών. Οι παρατηρήσεις της μελέτης αυτής θέτουν σε αμφισβήτηση το παραδοσιακό τρόπο κατανόησης της περιφερειακής επαναστένωσης εντός του stent ως μιας απλής υπερπολλαπλασιαστικής απάντησης στο βαρότραυμα. Η απεικόνιση με FD-OCT είναι ένα βέλτιστο πειραματικό εργαλείο για την αξιολόγηση της εξέλιξης της αθηροσκληρωματικής νόσου και την επαναστένωση του αγγείου. Μπορεί να παρέχει υψηλής ευκρίνειας ενδοαγγειακή απεικόνιση κατά τη διάρκεια αγγειοπλαστικών επεμβάσεων στα κάτω άκρα και θα μπορούσε να αποδειχθεί κλινικά χρήσιμο για τον προσδιορισμό της εντός του stent πρόπτωσης ιστού και του strut malapposition. Παρ 'όλα αυτά, δεν πρέπει να χρησιμοποιηθεί ως εργαλείο για τη συνήθη κλινική πρακτική μέχρι να προκύψουν στοιχεία από περαιτέρω κλινικές δοκιμές για τον καθορισμό των ειδικών ενδείξεων της απεικόνισης με FD-OCT στις περιφερικές αρτηρίες. / Optical coherence tomography (OCT) is a catheter-based imaging method that employs near-infrared light to produce high-resolution intravascular images. OCT can readily visualize vessel microstructure at a 10- to 20-μm resolution with exquisite detail. To date, however, applicability of the method has been limited to small diameter arteries (≤4 mm). To the best of the author’s knowledge, this study is the first worldwide that demonstrates the safety and clinical feasibility of frequency domain Optical Coherence Tomography (FD-OCT) imaging of infrainguinal vessels in vivo during infrainguinal angioplasty procedures. It is also the first study that reports the use of intravascular FD-OCT to detect and characterize in-stent neointimal tissue following infrapopliteal drug eluting stent (DES) placement in patients suffering from critical limb ischemia. Quantitative lumen analysis of arteries with diameter up to 7 mm was performed. High-resolution OCT images provided exquisite two-dimensional axial and longitudinal views of the infrainguinal arteries and allowed thorough investigation of a variety of angioplasty sequela, including and not limited to intimal tears and dissection flaps, white and red thrombus, stent mesh malapposition, and intrastent plaque prolapse. Of interest, OCT identified cases of suboptimal postangioplasty outcome that single-plane subtraction angiography did not recognize and accounted. Mixed features of lipid pool areas, calcium deposits and calcified plaques, necrotic areas, and fibrosis were identified in all of the imaged atherosclerotic lesions. However, based on the predominant baseline imaging findings, lesions under investigation were classified as purely fibrotic, fibrocalcific, mostly lipid-laden and necrotic/calcified. Intraplaque accumulation of macrophages was noted in some of de novo atheromatic lesions. Varying degrees of neointimal hyperplasia were demonstrated in all cases of in stent restenosis (ISR) lesions with purely fibrotic features and considerable neovascularization in some of them. The latter finding coincided with the level of maximum vessel stenosis in all cases. Neoatherosclerosis following infrapopliteal DES placement is a frequent finding in both symptomatic and asymptomatic patients. Our preliminary observations allow us to speculate that analogous to coronary implanted DES, defective endothelialization induced by the eluted drug, along with neovascularization developing between the stent struts, may incite neointimal neoatherosclerosis, which may result in ISR and lumen loss of the peripheral arteries. It also seems that infrapopliteal neoatherosclerosis may be a significant contributing factor for ISR rather than a minor and sporadic process, highlighting the clinical significance of the phenomenon. Our observations put in dispute the traditional way of understanding peripheral in-stent restenosis as a simple hyperproliferative response to barotraumas and may explain the paramount importance of aggressive risk factor modification strategies. Neointimal neoatherosclerosis as identified by FD-OCT may have a role in the development of below-the-knee restenosis and thus warrants further investigation by larger controlled studies. Moreover, it may prove clinically useful for the determination of intrastent tissue prolapse and strut malapposition. FD-OCT should not be utilized as a tool for routine clinical practice until evidence from further clinical trials emerge to determine the specific indications for OCT imaging of the peripheral arteries.

Page generated in 0.1084 seconds