• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2931
  • 88
  • Tagged with
  • 3019
  • 3019
  • 1422
  • 1333
  • 871
  • 642
  • 295
  • 290
  • 274
  • 258
  • 243
  • 226
  • 221
  • 209
  • 205
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Estudo de vida em fadiga de parafusos pediculares revestidos com hidroxiapatita

Larrubia, Davis Machado 30 August 2013 (has links)
Made available in DSpace on 2016-06-02T19:12:33Z (GMT). No. of bitstreams: 1 5545.pdf: 5030792 bytes, checksum: db0e89c0cabf8fcafd5e7da0160756a0 (MD5) Previous issue date: 2013-08-30 / The search for new materials or changes in the manufacture process for the surgical implant companies have been considered one the most challenging issues for the engineering in order to supply high performance products and minimize the damage to the post-operated patient, reducing the recovery time through the improved acceptance and stability of the organism regarding the implanted medical device. Alternatives for the decrease in the time to reach the arthodesis can be obtained through the Surface Treatment technique. The possible use of bioceramics with coating in metallic parts, may increase the bone growth rate of the deposited bioceramic when the adequate parameters are used, although the thermal spray process may impact the fatigue life. This study intends to analyses the life of dynamic loading of a Pedicular Fixation System with the presence of a coated hydroxyapatite film deposited on the surface of the screws through the Flame Spray technique, using a methodology in according with the prescribed by the preface of the standard ASTM F 1717 (Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model). The mechanical properties of the coating were found satisfactory, although changes in the coating process are required in order to reach the correct Ca/P ratio. / As pesquisas por novos materiais ou modificações de processamento para as indústrias de implantes têm sido alguns dos grandes desafios da engenharia para fornecer produtos de alto desempenho e minimizar os danos no pós-operatório de pacientes submetidos à intervenção cirúrgica, além de diminuir o tempo de recuperação dos mesmos através de maior aceitação e estabilidade do organismo ao produto médico implantado. Alternativas para diminuir o tempo de obtenção da artrodese podem ser obtidas através de técnicas de Engenharia de Superfície. A possibilidade de utilização de biocerâmicas como recobrimento de peças metálicas, pode proporcionar maior taxa de crescimento ósseo quando depositada nos parâmetros adequados, embora o processo de aspersão térmica possa ocasionar alterações significativas da vida em fadiga do corpo metálico. Este estudo busca verificar a vida sob compressão dinâmica de um sistema de fixação pedicular que possui seus parafusos recobertos por hidroxiapatita através da técnica de Flame Spray seguindo os prefácios da norma ASTM F 1717 (Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model). O comportamento mecânico da peça recoberta se mostrou satisfatório, entretanto há a necessidade de alterações nos parâmetros de processo para que a correta relação Ca/P seja obtida.
272

Estudo da cinética de oxidação em altas temperaturas da liga SV15 aplicada na fabricação de sedes de válvulas de escape de motores automotivos / Study of high temperature oxidation kinetics of sv15 alloy applied in the manufacture of exhaust valve seat inserts for automotive engines

Alano, José Henrique 14 April 2014 (has links)
Made available in DSpace on 2016-06-02T19:12:39Z (GMT). No. of bitstreams: 1 6352.pdf: 2348176 bytes, checksum: 039627270b2d6b2e1f0f56849a1b0319 (MD5) Previous issue date: 2014-04-14 / Financiadora de Estudos e Projetos / The SV15 alloy is applied in the production of the exhaust valve seats of automotive engines. The conditions of service in which the part is submitted require materials resistant to oxidation because of high temperature and aggressive atmosphere in which the material is exposed. The evaluation of high-temperature oxidation of the SV15 alloy is important therefore contributing in the selection or not of the material in other applications as severe as the automotive engine. The high-temperature oxidation in the alloy SV15 was studied by thermogravimetry in an atmosphere of O2 for a period of one hour at temperatures of 660°C, 740°C, 860°C and 900°C. The microstructure and chemical composition of the alloy were determined by scanning electron microscopy (SEM), and the phases present in the alloy were studied by X-ray diffraction (XRD). The SEM technique was also used to assess the microstructure, morphology, thickness and chemical composition of the oxide layer. To determine the phases presented by the oxide layer were used the techniques of Fourier transform infrared spectroscopy (FTIR), FT-Raman and XRD. The oxides formed at 660°C and 740°C follow the linear rate law, while the layers formed at 860°C and 900°C showed two stages of oxidation, an initial linear stage and a second parabolic stage. The first stage of oxidation showed an oxide formed mainly by NiCr2O4 while the second stage was composed of Cr2O3. The oxidation mechanism in the first stage of oxidation was controlled by the reaction rate of the oxygen with the metallic substrate, while the second stage of oxidation was controlled by reducing the diffusion of Ni+2 through the NiCr2O4 layer. / A liga SV15 é aplicada na produção de sedes de válvulas de escape de motores automotivos. As condições de serviço em que a peça é submetida exigem materiais resistentes à oxidação em virtude da alta temperatura e atmosfera agressiva em que o material é exposto. A avaliação da oxidação em alta temperatura da liga SV15 é importante, pois contribuí na seleção ou não do material em outras aplicações tão severas quanto o motor automotivo. A oxidação em altas temperaturas da liga SV15 foi estudada por termogravimetria sob atmosfera de O2 por um período de uma hora nas temperaturas 660°C, 740°C, 860°C e 900°C. A microestrutura da liga foi determinada por microscopia eletrônica de varredura (MEV), e as fases presentes na liga foram estudadas por difração de raios X (DRX). A técnica de MEV também foi usada para determinar a microestrutura, morfologia, espessura e composição química da camada de óxido. Para determinação das fases apresentadas pela camada de óxido foram utilizadas as técnicas de espectroscopia no infravermelho com transformada de Fourier (IVTF), FT-Raman e difração de raios X. Os óxidos formados a 660°C e 740°C seguiram a lei de velocidade linear, enquanto que as camadas formadas a 860°C e 900°C apresentaram dois estágios de oxidação, um primeiro estágio linear e um segundo estágio parabólico. O primeiro estágio de oxidação apresentou um óxido formado principalmente por NiCr2O4 enquanto que o segundo estágio foi formado por Cr2O3. O mecanismo de oxidação do primeiro estágio de oxidação foi controlado pela taxa de reação do oxigênio com o substrato metálico, enquanto que o segundo estágio de oxidação foi controlado pela diminuição na difusão do Ni+2 através da camada de NiCr2O4.
273

Caracterização da fabricação e uso de compósitos poliméricos contendo fibras naturais com ênfase no polipropileno/sisal a partir da análise de documentos de patentes / Manufacturing and use of natural fibres composites containing natural fibres, with emphasis on sisal, through patent analysis

Scopel, Felipe 24 January 2012 (has links)
Made available in DSpace on 2016-06-02T19:12:41Z (GMT). No. of bitstreams: 1 6540.pdf: 3026610 bytes, checksum: e6bb678fa1bc2065988fdf93709610c1 (MD5) Previous issue date: 2012-01-24 / Natural fibers have became important as substitute for synthetic fiber reinforcement and filling in polymer composites, looking for better properties, lower cost and appeal of sustainability. To do so, there are challenges and limitations to be overcome, such as the compatibility of fiber/matrix, the processing temperature, the moisture absorption and so on. The global auto industry, including Brazil, has led the use of composites containing natural fibers in commercial products and also serves as reference to other economic areas. In Brazil, the fomentation agencies have supported projects in natural fibers and their application in composites, with a significant amount of academic research groups working in this area. The aim of this study was to analyze the situation and trends in the manufacturing and use of materials containing natural fibers through patent analysis, with emphasis on sisal, and also to simulate a sisal/polypropylene composite in home appliance part. Materials, processes, practices and actors involved in these composites were mapped, based on indicators made from patent documents. The analysis of patent documents associated with natural fibers and their use in polymer composites, in the period of 1960 to 2009, demonstrated the growing importance of this subject in the world and particularly in Brazil. Among other results, it was found that Brazil holds the 16th position in patenting associated with natural fibers in general and the 12th place in patenting on the sisal fiber, despite being the world's largest producer of sisal and one of the largest producers of natural fibers in general. Companies and individuals assignees have the largest number of patent documents, when compared to universities and institutes. It was possible to make recommendations for the development of a sisal/polypropylene part through exploratory structural simulation. It was also needed to generate new data to enable simulation of the injection process. / As fibras naturais possuem uma crescente importância como alternativa às fibras sintéticas de reforço e carga de origens não renovável em compósitos poliméricos, buscando a combinação de propriedades, menor custo e apelo de sustentabilidade econômica, ambiental e social. Porém, ainda existem desafios técnicos, como a compatibilidade fibra/matriz, temperatura de processamento e absorção de umidade. Essa é uma área importante para o Brasil, pela sua proeminência na produção de fibras naturais. No Brasil, os órgãos de fomento à pesquisa e ao desenvolvimento têm apoiado projetos em fibras naturais, existindo expressiva quantidade de grupos de pesquisa acadêmicos. O objetivo da presente pesquisa foi analisar a situação e as tendências de fabricação e do uso de materiais contendo fibras naturais, enfatizando o sisal, a partir da análise de patentes e do estudo exploratório da simulação de uma peça de eletrodoméstico. Foram mapeados os avanços temporais dos materiais, processos, usos e atores envolvidos com fibras naturais, com indicadores elaborados a partir de documentos de patentes. A análise de documentos de patentes associadas às fibras naturais e seu uso em compósitos poliméricos, realizada entre 1960-2009, permitiu verificar a importância crescente deste tema no cenário mundial e brasileiro. Dentre outros resultados, verificou-se que o Brasil detém a 16ª posição no patenteamento associado às fibras naturais em geral e a 12ª colocação no patenteamento relativo à fibra de sisal, apesar de ser o maior produtor mundial dessa fibra e um grande produtor de fibras naturais. As empresas e pessoas físicas detêm o maior número de documentos de patentes, quando comparadas às universidades e institutos. Foi possível estabelecer recomendações para novas etapas do desenvolvimento de um pino de eletrodoméstico de polipropileno/sisal por simulação estrutural exploratória. Através deste estudo, verificou-se também a necessidade de geração de novos dados dos compósitos para viabilizar a simulação do processo de injeção.
274

Processamento e caracterização de ligas a base de magnésio para uso como implantes bioabsorvíveis / Processing and characterization of magnesium based alloys for use as bioabsorbable implants

Asato, Gabriel Hitoshi 23 February 2015 (has links)
Submitted by Daniele Amaral (daniee_ni@hotmail.com) on 2016-09-20T19:45:46Z No. of bitstreams: 1 DissGHA.pdf: 13366007 bytes, checksum: acbd6059ecbc13c4382351dfa90d5c59 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-21T13:04:30Z (GMT) No. of bitstreams: 1 DissGHA.pdf: 13366007 bytes, checksum: acbd6059ecbc13c4382351dfa90d5c59 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-21T13:04:36Z (GMT) No. of bitstreams: 1 DissGHA.pdf: 13366007 bytes, checksum: acbd6059ecbc13c4382351dfa90d5c59 (MD5) / Made available in DSpace on 2016-09-21T13:04:42Z (GMT). No. of bitstreams: 1 DissGHA.pdf: 13366007 bytes, checksum: acbd6059ecbc13c4382351dfa90d5c59 (MD5) Previous issue date: 2015-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Magnesium alloys have attracted great interest for use in temporary orthopedic implants to replace existing materials, due to the combination of physical, mechanical and corrosive properties. A magnesium based alloy containing zinc and calcium have been proposed and studied due to its biocompatibility and lower corrosion rate than the pure element. Zinc improves the mechanical properties and corrosion resistance, increasing the potential for corrosion. Calcium promotes grain refinement during solidification and increases the strength and toughness with a second phase precipitation. Amorphous materials have greater homogeneity of composition resulting in improved corrosion resistance and mechanical properties due to the nature of its structure. Recent research at DEMa-UFSCar showed that levels close to 5% at. were more likely to the formation of amorphous phase. This work aims to study the influence of calcium content in relation to mechanical and corrosive properties. The processing method is also evaluated, taking as parameters the proximity of the composition with the theoretical values and the oxygen content in the composition of the final alloy. The materials were characterized through scanning electron microscopy techniques (SEM), X-ray diffraction (XRD), differential scanning calorimetry (DSC), chemical analysis by optical emission spectrometer with inductively coupled plasma (ICP-OES) and spectrometer absorption of infrared radiation, conventional compression test and potentiodynamic polarization test. The results show that the increase of calcium content favors both compressive strength and corrosion resistance. / Ligas de magnésio têm despertado grande interesse para uso em implantes ortopédicos temporários em substituição aos materiais existentes no mercado, devido a combinação de propriedades físicas, mecânicas e corrosivas. Uma liga de magnésio com zinco e cálcio foi proposta e estudada devido a sua biocompatibilidade e taxa de corrosão menor que do elemento puro. O zinco melhora as propriedades mecânicas e a resistência à corrosão, aumentando o potencial de corrosão. O cálcio favorece o refinamento do grão na solidificação e aumenta a resistência e a tenacidade com a precipitação de segunda fase. Materiais amorfos, por sua vez, apresentam maior homogeneidade resultando em melhores propriedades de resistência à corrosão e mecânicas devido à natureza de sua estrutura. Trabalhos recentes realizados no DEMa-UFSCar mostraram que teores próximos de 5%at. apresentaram maior tendência a formação de amorfo. Este trabalho visa o estudo da influência do teor de cálcio em relação às propriedades mecânicas e corrosivas. A metodologia de processamento também é avaliada, tomando como parâmetros a proximidade da composição com os valores teóricos e pelo teor de oxigênio na composição das ligas finais. Os materiais foram caracterizados através das técnicas de microscopia eletrônica de varredura (MEV), difração de raios X (DRX), calorimetria diferencial de varredura (DSC), análise química por espectrômetro de emissão ótica com plasma acoplado indutivamente (ICP-OES) e espectrômetro de absorção de radiação infravermelha, ensaio mecânico de compressão convencional e ensaio de polarização potenciodinâmico. Os resultados mostraram que o aumento do teor de cálcio favorece positivamente tanto a resistência mecânica à compressão quanto a resistência à corrosão.
275

Deposição e caracterização de revestimentos de Ni-Ti e Ni-Ti/Nb para aplicações biomédicas

Vargas, André Luís Marin January 2007 (has links)
Made available in DSpace on 2013-08-07T18:53:54Z (GMT). No. of bitstreams: 1 000396764-Texto+Completo-0.pdf: 5447809 bytes, checksum: 95a031242ec95fc4971f2c3bd2c511a0 (MD5) Previous issue date: 2007 / Among all kinds of shape memory alloys, NiTi are probably the most important and used due to its improved mechanical and tribological properties. Bulk NiTi alloys are widely applied as biomedical materials and in diverse fields of microengineering. The importance of NiTi alloys resides on the effects of superelasticity (pseudoelasticity) (PE) and shape memory (SME), which permits these materials alter its phase on specific conditions and the return to its the original state. Nevertheless, NiTi thin films were rarely applied on biomedical applications, mostly due to the difficulty to produce NiTi coatings capable to achieve the same properties verified in the bulk material. In order to accomplish that, it is necessary to alter the atomic concentration of the alloy precisely and to produce its crystalline phase. Other possibility is the use of multilayers films, which can be produced mostly by magnetron sputtering. Allied to a specific thermal treatment, which provides the transformation of an amorphous phase to a crystalline one, it might be possible to develop NiTi thin films focused to biomedical applications. The main objective of this work is to deposit monolhitical NiTi thin films, as well as Ti / NiTi and Nb / NiTi multilayers using the DC magnetron sputtering method, intending to achieve mechanical and tribological properties suitable for biomedical applications. X-ray diffraction (DRX) and X-ray fluorescence were applied to the characterized crystalline structure and composition of coatings respectively. Hardness and elastic modulus were characterized using nanoindentation technique. Corrosion assays were conducted according to the ASTM F746 standard. The results obtained showed that NiTi thin films presents characteristics that permits its application as biomedical materials. / Entre as ligas de memória de forma (SMA – shape memory alloys) as de níquel-titânio (Ni-Ti) são as mais importantes e práticas devido, principalmente, às suas excelentes propriedades mecânicas, excelentes propriedades que resistem à corrosão, etc. A importância dessas ligas, além do efeito de memória de forma (SME), também está relacionada aos efeitos de Superelasticidade ou Pseudoelasticidade (PE), o que permite a esse material alterar suas fases sob condições específicas e retornar à sua forma original. Essas ligas são utilizadas em aplicações biomédicas (material em volume), e em diversos campos da micro engenharia. Entretanto, filmes finos de NiTi são raramente utilizados em aplicações biomédicas, em sua maioria devido à dificuldade em produzir filmes capazes de produzirem os mesmos efeitos encontrados no material em volume. Para tal, é preciso alterar as concentrações atômicas dos filmes de maneira precisa, a fim de se obter a fase cristalina necessária para a ocorrência de tais efeitos. Outra possibilidade é a utilização de filmes do tipo multicamada, os quais são produzidos em sua maioria pela técnica de Magnetron Sputtering, aliado a um tratamento térmico específico, o que possibilita a transformação de uma estrutura amorfa para uma cristalina. O objetivo deste trabalho é depositar filmes finos monolíticos e do tipo multicamada de Ni-Ti/Ti e NiTi/Nb pela técnica de DC Magnetron Sputtering para aplicações biomédicas e caracterizar propriedades mecânicas de dureza e módulo de elasticidade, composição química e estrutura cristalina, e a resistência à corrosão dos mesmos antes e após o tratamento térmico das ligas depositadas. Medidas de difração de raios X (DRX), e de fluorescência de raios X (FRX), mostraram que a estrutura cristalina e a composição foram obtidas com sucesso. As propriedades mecânicas e de resistência à corrosão apresentadas por estes revestimentos mostraram características excelentes de biocompatibilidade. Os ensaios de corrosão foram feitos segundo as recomendações contidas na norma ASTM F746.
276

Propriedades tribocorrosivas de multicamadas TI/TIN: dependência do comprimento de modulação e proporção da camada cerâmica

Jacobsen, Saulo Davila January 2007 (has links)
Made available in DSpace on 2013-08-07T18:54:11Z (GMT). No. of bitstreams: 1 000390390-Texto+Completo-0.pdf: 5911788 bytes, checksum: 86d66873f5ffc52b061362edf8178ade (MD5) Previous issue date: 2007 / The application of TiN coatings as steel protective layers in situations with tribocorrosive characteristics has achivied much success along the years. However, the resistance against aqueous corrosion is reached only when the protective layer is free of imperfections, since corrosive attack propagates in defects associated to pores, grain boundaries and to the columnar morphology found in monolithic films deposited by sputtering. Recent studies demonstrated that a possible solution to prevent the propagation of the columnar structure is the production of multilayer coatings, thus promoting barriers against the aggressive environment. In specific conditions, nanostructured multilayer films present high hardness values, in accordance with the modulation period variation. The objective of this work is to show the tribocorrosive behavior of Ti/TiN multilayers, deposited by magnetron sputtering technique, with various modulation lengths and different TiN ratios for each modulation. Rutherford backscattering (RBS) and X ray reflectometry (XRR) measurements exhibit that the multilayers had been successfully produced. The mechanical properties presented by these films showed characteristics of hardness superlattices and allied to protective corrosive properties. Qualitative measurements of mechanical wear (H/E) demonstrated high degree of protection, presenting a great potential for practical applications. / A aplicação de revestimentos de nitreto de titânio como camada protetora de aços em situações com características tribocorrosivas tem obtido muito sucesso ao longo dos anos. Entretanto, a resistência contra corrosão aquosa só é obtida quando a camada protetora for destituída de imperfeições, pois o ataque corrosivo se propaga em defeitos associados à poros, contorno de grãos, e à uma morfologia colunar encontrada em filmes monolíticos depositados por sputtering. Estudos recentes mostraram que uma possível solução para evitar a propagação da estrutura colunar é a produção de revestimentos tipo multicamadas, promovendo assim barreiras para o meio agressivo. Em condições específicas, filmes nanoestruturados do tipo multicamadas apresentam valores extremamente elevados de dureza, de acordo com a variação do seu período de modulação. O objetivo deste trabalho é mostrar o comportamento tribocorrosivo de multicamadas de Ti/TiN, depositados pela técnica de magnetron sputtering, através de diversos comprimentos de modulação e diferentes proporções de TiN para cada modulação. Medidas de Espectrometria de Retroespalhamento de Rutherford (RBS) e de refletividade de raio X (XRR) mostraram que as multicamadas foram obtidas com sucesso em seu processo de deposição. As propriedades mecânicas apresentadas por esses revestimentos mostraram características de super-rede de dureza e as propriedades corrosivas aliadas às medidas qualitativas de desgaste mecânico (H/E) mostraram elevado grau de proteção, apresentando um grande potencial para aplicações práticas.
277

Avaliação da rigidez axial de juntas parafusadas

Cardoso, Raphael Calazans 23 February 2018 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The procedures of bolted joints design must correspond appropriately with real conditions, to ensure projects of high reliability. Therefore, this study aims to evolve the understanding of the mechanical behavior of bolted joints during the preloading, external loading and fatigue life stages. For this, was performed finite elements analysis, experimental analysis and calculation analytical methods based on several procedures found in the literature, in order to compare the magnitude of the joint stiffness parameter. It was observed that the results provided through the analytical method of VDI 2230, finite element analysis and experimental analysis obtained an excellent agreement. Furthermore, from the VDI 2230 standard, the mean and alternating stresses were determined on the bolts belonging to the bolted joints tested in fatigue and then compared with criteria of fatigue evaluation established for bolts obtaining good coherence. These results indicate that the VDI 2230 standard represents well the mechanical behavior of the joint and should be used as the main guideline for the reliable design of bolted joints. / Os procedimentos de dimensionamento de juntas parafusadas devem corresponder adequadamente às condições impostas na prática, para garantir projetos de alta confiabilidade. Por isso, este estudo tem o objetivo de evoluir na compreensão do comportamento mecânico de juntas parafusadas quando das etapas de pré-carregamento, de aplicação de carga externa e da vida em fadiga. Para tal foram realizadas análises por elementos finitos, por extensometria e por cálculo analítico a partir de diversos procedimentos encontrados na literatura, de modo a comparar a magnitude da rigidez global da junta. Foi observado que os resultados encontrados através do método analítico da norma VDI 2230, da análise por elementos finitos e por extensometria obtiveram ótima concordância. Além disso, a partir da norma VDI 2230, foram determinadas as tensões médias e alternantes nos parafusos de juntas parafusadas ensaiadas em fadiga e então comparadas com critérios de avaliação de fadiga estabelecidos para parafusos sendo obtida boa coerência. Tais resultados apontam que a norma VDI 2230 representa bem o comportamento mecânico da junta e deve ser utilizada como a principal diretriz para o dimensionamento confiável de uniões parafusadas. / São Cristóvão, SE
278

Síntese e propriedades de Ce1-xGdxO2-x/2 (x=0;0,1 e 0,2) obtidos pelo método hidrotermal assistido por micro-ondas / Synthesis and properties of Ce1-xGdxO2-x/2 (x=0;0,1 e 0,2) obtained by microwave assisted hydrothermal method

Carregosa, João Domingos Covello 07 February 2017 (has links)
Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The solid solution of Gd3+ doped CeO2 (GDC) is a promising candidate for electrolyte in SOFCs (Solid Oxide Full Cells) operating in intermediate and low temperatures. The reduction of the working temperature of these energy conversion devices is the great technological challenge to its marketing. In this work, nanocrystalline powders of Ce1-xGdxO2-x/2 with x=0; 0.1 e 0.2 were obtained by microwave-assisted hydrothermal synthesis at low temperature and times of synthesis (10 and 20 min at 120 °C). The powders were analyzed by TG-DTA, SEM, XRD and dilatometry. The results showed characteristic peaks of the cubic fluorite structure, referring to the cerium oxide (CeO2), without the presence of secondary peaks. We also observed that the samples synthesized at 10 and 20 minutes showed distinct behaviors in function of the concentrations of Gd3+. In addition, immersion tests were performed for the sintered ceramics, by Archimedes method. The relative density values were above 92% for all the proposed formulations. / A solução sólida de CeO2 dopada com Gd3+ (CGO) é um promissor candidato para eletrólito de SOFCs (Solid Oxide Full Cells) operantes em temperaturas intermediárias e baixas. A redução da temperatura de trabalho destes dispositivos de conversão de energia é o grande desafio tecnológico para a sua comercialização. Nesse trabalho, pós nanocristalinos de Ce1-xGdxO2-x/2 com x=0; 0,1 e 0,2 foram obtidos via síntese hidrotérmica assistida por micro-ondas em temperatura e tempos de síntese baixos (10 e 20 min à 120 °C). Os pós foram analisados por TG-DTA, MEV, DRX e dilatometria. Os resultados indicaram picos característicos da estrutura cúbica tipo fluorita, referente ao óxido de cério (CeO2), sem presença de picos secundários. Observou-se também que as amostras processadas em patamares de 10 e 20 minutos apresentaram comportamentos distintos frente aos teores de Gd3+ estudados. Além disso, foram realizados ensaios de imersão das cerâmicas sinterizadas, pelo método de Arquimedes. Os valores de densidade relativa ficaram acima de 92% para todas as formulações propostas.
279

Estudo da influência do índice de fluidez na cinética de critalização de blendas de PP homopolímero com PP copolímero / Study of the Influence of the Melt Index on the Crystallization Kinetics of PP Blends homopolymer and PP copolymer

Silva, Emanuela Santos 06 October 2017 (has links)
The present work had as objective productions and images of homopolymer PP with heterophasic PP copolymer, seeking to investigate how the fluidity index influenced as the good of the blends. As Blends PPh11 / CP and PPh1.5 / CP were produced by varying the copolymer content (CP) by 25, 50 and 75%. The melt flow indexes of homopolymer PP and PP copolymer were: 11g / 10min (PPh11), 1.5g / 10min (PPh1,5) and 0,8g / 10min (CP). As the legends were prepared in a monorail extruder. The oscillatory dynamic rheological properties were evaluated in an oscillatory shear rheometer. Through the tensile test an evaluation of the mechanical properties was made. A determination of the crystalline phases of the compositions at the exit of the X-ray Diffraction. An analysis of the thermal properties and the study of the non-isothermal crystallization kinetics was performed from Differential Exploratory Calorimetry (DSC). There is no non-isothermal study, as samples were warmed from room temperature to 200 ° C and cooled using 10, 15 and 20 ° C / min cooling rates. A non-isothermal crystallization kinetics for the study of Ozawa, Jeziorny and Kissinger Methods. The results showed that the heterophasic copolymer acted as a nucleant in the more viscous compositions, prepared with PPh1.5. And as crystallization (Ti) and peak crystallization (Tc) temperatures were shifted to higher values. The kinetic parameters, n and kc, behaved in the same manner for all compositions, indicating the growth geometry of the crystal was not affected. Rheological and mechanical characterizations indicate that all systems studied are miscible. / O presente trabalho teve como objetivo produzir e caracterizar blendas de PP homopolímero com PP copolímero heterofásico, buscando investigar como o índice de fluidez influencia as propriedades das blendas. As blendas PPh11/CP e PPh1,5/CP foram produzidas variando-se o teor de copolímero (CP) em 25, 50 e 75%. Os índices de fluidez dos PPs homopolímeros e do PP copolímero foram: 11g/10min(PPh11), 1,5g/10min(PPh1,5) e 0,8 g/10min(CP). As blendas foram preparadas em uma extrusora monorrosca. As propriedades reológicas em regime dinâmico oscilatório foram avaliadas em um reômetro de cisalhamento oscilatório. Através do ensaio de tração foi feita a avaliação das propriedades mecânicas. A determinação das fases cristalinas das composições foi feita a partir da Difração de raios-X. A análise das propriedades térmicas e o estudo da cinética de cristalização não isotérmica, foi realizada a partir da Calorimetria Exploratória Diferencial (DSC). No estudo não isotérmico, as amostras foram aquecidas da temperatura ambiente até 200ºC e, resfriadas usando as taxas de resfriamento de 10, 15 e 20 ºC/min. A cinética de cristalização não isotérmica foi estudada aplicando os Métodos de Ozawa, Jeziorny e Kissinger. Os resultados mostraram que o copolímero heterofásico atuou como nucleante nas composições mais viscosas, preparadas com o PPh1,5. E as temperaturas de início de cristalização (Ti) e de pico de cristalização (Tc) foram deslocadas para valores mais elevados. Os parâmetros cinéticos, n e kc, se comportaram da mesma maneira para todas as composições, indicando que a geometria de crescimento do cristal não foi afetada. Os resultados das caracterizações reológica e mecânica indicam que os sistemas estudados são miscíveis. / São Cristóvão, SE
280

Estudo das transformações microestruturais decorrentes do tratamento criogênico em ligas de titânio (TiNbSn) pré deformadas a frio / Study of microstructural transformations arising from cryogenic treatment in titanium alloys (TiNbSn) preformed to cold

Silva, Abraão Santos 16 February 2017 (has links)
Titanium alloys have been interesting combinations of mechanical properties and corrosion, thus generating great acceptance as structural material in aircraft components and also as a substitute of bone tissue, which justifies how many researches are being developed. The concentrations of the mechanical conformation (80% cold deformation), thermal treatments of solubilization, water quenching, Cryogenic treatment (-198ºC) and aging treatment through Vickers microhardness, metallography and image analysis techniques. The results demonstrate that the treatment is critical after an increase in the hardness of the alloy with less than 5.0% of tin, and this result is the result of Beta (CCC) and α "(Ortorrômbica) tension. Results from the hardness analyzes showed that the treatment should be followed by an increase in the number of martensite needles or an improvement in the hardness property. The image analysis demonstrated the same pattern in a quantitative manner. Construction of a temperature measurement system for the construction of a temperature measurement system. / Ligas de titânio têm apresentado interessantes combinações de propriedades mecânicas e de corrosão, gerando assim grande aceitação como material estrutural em componentes de aeronaves e também como substituinte do tecido ósseo, o que justifica as diversas pesquisas que estão sendo desenvolvidas. O presente estudo avaliou as modificações das fases nas ligas Ti35Nb(0,0; 2,5; 5,0; 7,5)Sn decorrentes da conformação mecânica (80% de deformação a frio), tratamentos térmicos de solubilização, têmpera em água, tratamento criogênico (-198ºC) e tratamento de envelhecimento através das técnicas de microdureza Vickers, metalografia e análise de imagens. Os resultados demonstram que o tratamento criogênico após a têmpera aumentou significativamente a dureza da liga com teor inferior a 5,0 % de estanho, sendo que este resultado é decorrência da tensão imposta no tratamento criogênico o qual aumenta a semelhança entre as estruturas cristalinas da fase beta (CCC) e α” (Ortorrômbica). Os resultados das metalografias e de dureza demonstraram que o tratamento criogênico após a têmpera aumentou o número de agulhas de martensíta, responsáveis pela melhoria de propriedade de dureza. A análise de imagem demonstrou de maneira quantitativa o mesmo padrão. De acordo com os resultados encontrados foi possível concluir que a temperatura de total transformação para as ligas com teor superior a 2,5% de estanho é inferior a temperatura ambiental e que o tratamento criogênico é um processo eficaz na melhoria das propriedades mecânicas das ligas estudadas.

Page generated in 0.0924 seconds