• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 416
  • 26
  • 26
  • 26
  • 26
  • 18
  • 7
  • 7
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 425
  • 425
  • 279
  • 255
  • 154
  • 104
  • 65
  • 57
  • 57
  • 56
  • 55
  • 53
  • 52
  • 49
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Avaliação in vitro e in situ do efeito dos íons ferro na erosão da superfície dentária bovina e humana / In vitro and in situ evaluation of the effect of iron ions on the erosion of bovine and human dental surface

Melissa Thiemi Kato 05 March 2007 (has links)
O objetivo geral deste estudo foi avaliar o efeito do íon ferro na inibição da erosão de dentes bovino e humano provocada por bebidas ácidas, em estudos in vitro e in situ. O estudo foi realizado em três etapas. No 1° subprojeto, foi avaliado, in vitro, o efeito de concentrações crescentes de ferro na dissolução do pó de esmalte bovino, quando adicionado à Coca-Cola® e à Sprite Zero®. A concentração de ferro, para a qual foi observada inibição de perda de fósforo, foi utilizada nos experimentos seguintes. Para se determinar a quantidade de esmalte dissolvido foi analisado o fósforo por método colorimétrico. Os dados foram analisados por ANOVA e teste de Tukey (p<0,05). No 2º subprojeto (in vitro), blocos de esmalte bovino foram expostos a 4 ciclos de desmineralização em Coca-Cola®, contendo ou não 10 mmol/L de ferro (experimental e controle, respectivamente). Cada ciclo de desmineralização foi seguido por um ciclo de remineralização em saliva artificial. O 3º subprojeto foi constituído por um estudo in situ, cruzado, no qual 10 voluntários utilizaram dispositivos palatinos, contendo 2 blocos de esmalte e 2 de dentina humanos durante 2 fases de 5 dias cada. A diferença entre estas fases foi a adição ou não de ferro a 10 mmol/L ao refrigerante tipo cola, antes da imersão do dispositivo na mesma. Os voluntários imergiram os dispositivos por 5 minutos em 150 mL de Coca-Cola®, contendo ou não ferro, 4 vezes ao dia. O efeito do ferro na inibição da erosão, tanto do 2º como do 3º subprojetos, foi avaliado pela %PDS e análise de desgaste. Os dados foram analisados usando teste t (p<0,05). Resultados: Subprojeto 1- quando ferro a 30 e 60 mmol/L foi adicionado à Coca-Cola®, uma redução na dissolução do pó de esmalte foi observada quando comparado ao controle (11 e 17%, respectivamente), enquanto concentrações menores não tiveram nenhum efeito. Com relação à Sprite Zero®, concentrações de ferro acima de 10 mmol/L não tiveram efeito significativo, enquanto concentrações maiores aumentaram significativamente a dissolução do pó de esmalte. Subprojeto 2- O ferro a 10 mmol/L reduziu significativamente o desgaste, mas aumentou significativamente a %PDS dos blocos de esmalte submetidos à erosão in vitro pela Coca-Cola®. Subprojeto 3- Para o esmalte, houve uma redução significativa no desgaste e uma redução não significativa na %PDS, quando o ferro foi utilizado foi diminuída, embora não significativamente. Para a dentina, houve redução significativa no desgaste e aumento significativo na %PDS quando da utilização do ferro. Assim, concluiu-se que o íon ferro pode reduzir a erosão de dentes bovino e humano provocada por bebidas ácidas, sendo esta ação dependente do tipo de ácido presente na bebida. / The general aim of this study was to evaluate the effect of iron ion on inhibition of the erosion of bovine and human teeth submitted to acidic drinks, using in vitro and in situ protocols. The study was conducted in 3 steps. At the first subproject, it was evaluated, in vitro, the effect of increasing iron concentrations on the dissolution of bovine enamel powder when added to Coke® or Sprite Zero®. The iron concentration for which an inhibition of enamel dissolution was observed was used in the subsequent experiments. The average concentration of phosphate released was analysed spectrophotometrically. Data were analyzed using ANOVA and Tukey?s test (p<0.05). In the second subproject, 24 specimens of bovine enamel were randomly assigned to 2 groups (experimental and control). They were exposed in vitro to 4 cycles of demineralization in Coke® containing or not 10 mmol/L of iron (experimental and control groups, respectively). Each demineralization cycle was followed by a remineralization cycle in artificial saliva. As for the third subproject, in an in situ crossover protocol, 10 volunteers wore palatal devices containing human 2 enamel and 2 dentin blocks during two 5-day crossover phases. The difference between these phases was the addition or not of iron at 10 mmol/L in Coke® before the immersion of the devices. The volunteers immersed the devices for 5 minutes in 150 mL of cola drink, containing or not iron, 4 times per day. The effect of iron on the inhibition of erosion in subprojects 2 and 3 was evaluated by %SMH and wear analysis. Data were analyzed using t test (p<0.05). Results: Subproject 1 - when iron at 30 and 60 mmol/L was added to Coke®, a significant reduction in the dissolution of powdered enamel was observed when compared to control (11 and 17%, respectively), while lowering iron concentrations did not have any effect on enamel powder dissolution. Regarding Sprite Zero®, iron concentrations up to 10 mmol/L had no significant effect, while higher concentrations significantly increased enamel powder dissolution. Subproject 2- Iron at 10 mmol/L significantly reduced the wear, but significantly increased the %SMH of enamel blocks submitted to in vitro erosion by Coke®. Subproject 3- For enamel, when iron was used, a significant reduction in the wear and a non-significant reduction in the %SMH were observed. For dentin, the use of iron significantly reduced the wear but significantly enhanced the %SMH. Hence, we concluded that iron ion may reduce the erosion of bovine and human teeth caused by acidic drinks, depending on the type of acid present in the beverage.
252

Avaliação in vitro da eficácia de dentifrícios de baixa concentração de fluoreto suplementados com hexametafosfato sobre o processo de desmineralização do esmalte

Camara, Danielle Mendes da [UNESP] 28 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-28Bitstream added on 2014-06-13T20:17:06Z : No. of bitstreams: 1 camara_dm_me_araca.pdf: 818938 bytes, checksum: 54742da04cf41f01f0460d44699f8155 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Formulações de dentifrícios com concentrações reduzidas de fluoreto (F) têm sido estudadas para diminuir o risco de fluorose dentária. O objetivo do trabalho foi avaliar a eficácia de dentifrícios com concentrações reduzidas de F (250 μgF/g), suplementados com hexametafosfato (HMP) sobre a desmineralização do esmalte de dente bovino. Blocos de esmalte foram submetidos a repetidas ciclagens de pH alternadas com tratamentos (2x/dia) com dentifrícios sem F contendo HMP nas concentrações de 0, 0,25, 0,5, 1,0, 2,0 e 3,0%, dentifrícios com 250 gF/g suplementados com HMP nas mesmas concentrações, placebo (sem F e HMP), um com 500 μgF/g, outro com 1100 μgF/g e um comercial (Crest, de 1100 gF/g). Após as ciclagens determinou-se a dureza de superfície final (SHf), perda integrada de dureza de subsuperfície (ΔKHN) e o conteúdo de F no esmalte. Os resultados foram submetidos à ANOVA e teste de Bonferroni (p<0.05). O grupo 250 gF/g com 0,5% de HMP apresentou maior valor de SHf, e menor ΔKHN, seguido do grupo de 250 gF/g com 1,0% de HMP que ficou semelhante ao 1100 gF/g e Crest. HMP não interferiu na incorporação de F pelo esmalte em concentrações menores que 3%. Além disso, a adição de 0,5% de HMP a um dentifrício sem F causou um aumento de SHf e uma redução de ΔKHN em comparação ao placebo. Conclui-se que é possível reduzir a concentração de F a 250 gF/g e se obter uma ação comparável de um dentifrício comercial sobre a desmineralização do esmalte bovino através da suplementação com hexametafosfato nas concentrações de 0,5 e 1% / Formulations of dentifrices with reduced concentrations of fluoride (F) have been studied to decrease the risk of dental fluorosis. The aim of this study was to evaluate the efficacy of dentifrices with low concentration of F (250 μgF/g), supplemented with hexametaphosphate (HMP) on the demineralization of bovine tooth enamel. Blocks of enamel were submitted to repeated pH cyclings alternated with treatments (2x/day) with dentifrices without F or containing 250 gF/g supplemented with HMP at concentrations of 0, 0,25, 0,5 1,0, 2,0 e 3,0%, dentifrices supplemented with HMP the same concentrations, placebo (without F and HMP), a dentifrice with 500 μgF/g, another with 1100 μgF/g and a commercial dentifrice (Crest, 1100 gF/g). After cycling, the following analysis were conducted: final surface hardness (SHf), subsurface hardness integrated loss (ΔKHN) and the content of F on enamel. The results were submitted to variance analysis and Bonferroni test (p<0.05). The group of 250 gF/g with 0,5% HMP showed the highest SHf value and the lowest ΔKHN value, followed by the group supplemented with 1,0% HMP which was similar to 1100 gF/g and Crest groups. HMP did not impair the uptake of F by enamel at concentrations lower than3%. Furthermore the addition of 0,5% HMP to a non fluoridated dentifrice caused a rise on SHf and a decrease on ΔKHN in comparison to placebo. It was concluded that it is possible to reduce the concentration of F to 250 μgF/g and obtain an action similar to a commercial dentifrice on the demineralization of enamel by supplementation with hexametaphosphate in concentrations of 0.5 and 1%
253

Efeito do uso de dentifricios com alta e baixa concentração de fluoreto suplementado com trimetafosfato sobre a erosão e abrasão do esmalte dentário bovino: estudo in vitro

Moretto, Marcelo Juliano [UNESP] 20 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-20Bitstream added on 2014-06-13T20:17:09Z : No. of bitstreams: 1 moretto_mj_me_araca.pdf: 414954 bytes, checksum: 60caaf9816fb95bacf68715af56dc0f8 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O presente estudo teve como objetivo avaliar in vitro a ação de dentifrícios com alta e baixa concentração de fluoretos suplementado com trimetafosfato sobre a erosão associada ou não a abrasão. Foram utilizados 150 blocos de esmalte bovino (4x4mm) que após polimento foram selecionados através da microdureza de superfície (SMH inicial). Em seguida foram divididos em 5 grupos (n=30) de acordo com o dentifrício a ser utilizado: placebo (sem flúor), 1100 μg F/g - Crest™ , 1100 μg F/g , 500 μg F/g TMP 3%, 5000 μg F/g. Os blocos foram submetidos ao desafio ácido com Sprite Zero® por 5 minutos 4 vezes ao por um período de 7 dias. Na seqüência todos os blocos receberam tratamento com slurry dos dentifrícios (1:3) por 15 segundos. Metade dos blocos (n=15) foi submetido ao processo de abrasão através da escovação por 15 segundos utilizando escova elétrica Colgate Motion®. Todos os blocos permaneceram em saliva artificial antes e após os tratamentos(37°C). A análise estatística foi aplicada considerando como fatores de variação os dentifrícios experimentais (placebo, 1100 μg F/g Crest, 1100 μg F/g, 500 μg F/g TMP 3% e 5000 μg F/g) e o tipo de desafio erosivo (erosão e erosão/abrasão), e como variável os valores de dureza de superfície antes dos desafios, porcentagem de perda de dureza de superfície (%SMHC) e desgaste da superfície do esmalte (μm). As médias da porcentagem de perda dureza da superfície (% SMHC) e os valores médios do desgaste (μm) para os grupos submetidos a erosão foram de: placebo (sem flúor) 82,26 % e 3,36 μm, 1100 μg F/g - Crest™ 73,38% e 2.46 μm, 1100 μg F/g , 72,86% e 2,46 μm, 500 μg F/g TMP 3% 62,41% e 1,29 μm, 5000 μg F/g 64,06% e 1,46 μm. Já nos grupos submetidos à erosão associada à escovação, as médias da porcentagem de perda dureza da superfície (% SMHC) e os valores médios... / The aim of the present study was to evaluate the effectiveness of the application of high and lower fluorinated dentifrices supplementation with Trimetaphosphate on the erosion associated or not to the abrasion. It was used 150 bovine enamel blocks (4x4mm). These blocks were polished and after they were selected by the microhardness surface (initial SMH). After that, they were divided in 5 groups (n=30) in accordance with the dentifrice used: Placebo (without fluoride),1100 μg F/g Crest™, 1100 μg F/g, 500 μg F/g TMP 3%, 5000 μg F/g. The groups were submitted to the acid challenge with Sprite Zero® for 5 minutes, 4 times to the day, during 7 days. In the sequence all the blocks received treatment with slurry from dentifrices (1: 3) for 15 seconds. Half of each group (n=15) was submitted to the abrasion process by brushing for 15 seconds with electric brush Colgate Motion®. All the blocks remained in artificial saliva before and after the treatments (37oC). The analysis statistics was applied considering as variation factors the experimental dentifrices (placebo, 1100 μg F/g Crest™, 1100 μg F/g, 500 μg F/g TMP 3% and 5000 μg F/g) and the type of erosive challenge (erosion and erosion/abrasion), and as changeable the values of hardness of surface before the challenges, percentage of loss of surface hardness (%SMHC) and consuming of the surface of the enamel (μm). The averages of the percentage of loss hardness of the surface (% SMHC) and the average values of the consuming (μm) for the submitted groups the erosion were: placebo (without fluoride) 82,26 % and 3,36 μm, 1100 μg F/g - Crest™ 73,38% and 2.46 μm, 1100 μg F/g , 72,86% and 2,46 μm, 500 μg F/g TMP 3% 62,41% and 1,29 μm, 5000 μg F/g 64,06% and 1,46 μm. In the groups submitted to the erosion associated to the brushing, the averages of the percentage of loss hardness of the surface... (Complete abstract click electronic access below)
254

Avaliação de formulações dentifrícias com concentração reduzida de fluoreto associada ao trimetafosfato de sódio na desmineralização in vitro do esmalte dentário

Missel, Emilene Macário Coimbra [UNESP] 29 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-29Bitstream added on 2014-06-13T19:56:35Z : No. of bitstreams: 1 missel_emc_me_araca.pdf: 945569 bytes, checksum: 18dc8d6cf57fb388ce634f74b57fe2ba (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Apesar da adição de fluoreto (F) ao dentifrício ter promovido uma diminuição na incidência da cárie dentária, a sua ampla utilização foi acompanhada por um aumento na prevalência da fluorose dentária. A proposta deste trabalho foi avaliar a capacidade de formulações dentifrícias com concentração reduzida (250 μg/g) de F associada ao trimetafosfato de sódio (TMP) para inibir a desmineralização in vitro do esmalte dentário. Blocos de esmalte bovino foram selecionados e divididos em 8 grupos experimentais de 12 espécimes e submetidos durante 7 dias, a 5 ciclagens de pH. Os tratamentos foram realizados 2x/dia com suspensão de dentifrício com 0, 250, 500 e 1100 μg F/g; os dentifrícios com 250 μg F/g apresentaram concentrações de TMP entre 0 e 3,0%. Após as ciclagens determinou-se a dureza de superfície (SHf), perda integrada de dureza (ΔKHN) e conteúdo de F, cálcio (Ca) e fósforo (P) presente no esmalte. Os resultados foram submetidos à análise de variância seguido pelo teste de comparação múltipla de Bonferroni (p˂0,05). O perfil da área de desmineralização mostrou uma lesão de subsuperfície para todos os grupos, exceto para o grupo 250 μg F/g + 3,0% de TMP. A adição de 0,25% de TMP foi suficiente para aumentar a capacidade do F em reduzir a perda mineral, tanto para SHf quanto para KHN, sendo semelhante ao grupo 1100 μg F/g. O aumento na concentração do TMP para 0,50 e 1,0% não influenciou os resultados de SHf e KHN quando comparado ao grupo 250 μg F/g + 0,25% de TMP, mas alterou o perfil da área de desmineralização. Os grupos tratados com dentifrício com 0,25 a 1,0% de TMP apresentaram valores de F no esmalte semelhantes ao grupo 500 μg F/g (p˃0,05). Os dentifrícios 1100 μg F/g e 250 μg F/g + 0,25% de TMP apresentaram valores similares de Ca presente no esmalte (p˃0,05). Os valores de P presente... / Although the addition of fluoride (F) to dentifrice has reduced dental caries incidence, it is responsible for a raise in the prevalence of dental fluorosis. The aim of this study was to evaluate the ability of dentifrice formulations presenting low fluoride content (250 μg/g) associated to sodium trimetaphosphate (250 μg/g) to inhibit in vitro demineralization of dental enamel. Blocks were selected and submitted to 5 pH cycles during 7 days. Treatments were performed 2x/day with dentifrice slurry with 0, 250, 500 and 1100 μg F/g; dentifrices with 250 μg F/g presented TMP concentrations of 0 to 3%. Following that, surface hardness (SHf), integrated loss of hardness (ΔKHN) and F, calcium (Ca) and phosphorus (P) in enamel were determined. The results were submitted to analysis of variance followed by Bonferroni test (p˂0,05). The profile of the demineralization area showed a subsurface lesion for all groups, except for group 250 μg F/g + 3.0% of TMP. The addition of 0.25% of TMP was sufficient to improve the F ability to inhibit mineral loss at both analysis (SHf and KHN), making that group similar to group 1100 μg F/g. Raising the TMP concentration to 0.5 and 1.0% did not influence the results of SHf and KHN when compared to group 250 μg F/g + 0.25% of TMP, but it did alter the profile of the demineralization area. The groups treated with slurries of dentifrices with 0.25 to 1.0% of TMP showed values of F in enamel similar to group 500 μg F/g (p˃0.05). Dentifrices with 1100 μg F/g and 250 μg F/g + 0.25% of TMP presented similar values of Ca in enamel (p˃0.05). The values of P in enamel were similar among the groups (p>0.05). It was possible to conclude that the addition of 0.25% of TMP to a dentifrice presenting low F content (250 μg/g) may inhibit enamel demineralization and is similar to a 1100 μg F/g one
255

Avaliação in vitro da efetividade de dentifrícios de baixa concentração de fluoreto suplementados com fosfato / In vitro evaluation of dentifrices with low fluoride content supplemented with phosphate

Takeshita, Eliana Mitsue [UNESP] 21 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-21Bitstream added on 2014-06-13T19:36:00Z : No. of bitstreams: 1 takeshita_em_me_araca.pdf: 551995 bytes, checksum: 02ea87120ca07c0f4508263e987c52dd (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A redução da concentração de fluoreto (F) nos dentifrícios é importante para a prevenção da fluorose dental, entretanto, é necessário manter a mesma efetividade de um dentifrício de mercado (1100 mgF/g). O objetivo do presente trabalho foi avaliar in vitro se a suplementação com fosfato em dentifrícios com baixa concentração de F pode proporcionar eficácia semelhante a de um dentifrício padrão sobre a desmineralização do esmalte de dente bovino, utilizando modelo de ciclagem de pH. Blocos de esmalte selecionados foram submetidos a repetidas ciclagens de pH alternadas com tratamento diário com dentifrícios contendo 500 mgF/g e entre 0 e 3% de trimetafosfato de sódio (TMP); foram utilizados também um dentifrício sem adição de F e TMP (placebo) e um comercial (Crest, de 1100 mgF/g). Após as ciclagens foram determinadas a porcentagem de perda da microdureza de superfície, perda mineral (_Z) e conteúdo de F, cálcio (Ca) e fósforo (P) no esmalte. Foram utilizados testes paramétricos e não paramétricos e análise de correlação de Pearson para determinar diferenças e relação dose resposta entre os tratamentos. Os resultados mostraram que a adição de TMP (0,25-3,0%) a dentifrícios sem F causa uma diminuição na %SMH e na _Z, e quando adicionado a um dentifrício de 500 mgF/g o efeito final torna-se comparável a de um dentifrício de 1100 mgF/g. Observou-se também aumento na concentração de F na camada superficial da lesão com o aumento da concentração de TMP. Conclui-se que é possível reduzir a concentração de F a 500 mg/g e se obter uma ação comparável com a de um dentifrício comercial através da suplementação com fosfato sob a forma de TMP. / The reduction of fluoride (F) concentration in dentifrices is important to prevent dental fluorosis, but it is necessary to maintain their effectiveness. The aim of this study was to evaluate, in vitro, whether the phosphate supplementation of a dentifrice with low F content would provide a similar effect when compared to a standard dentifrice. Bovine enamel demineralization in a pH cycling model was used. Enamel blocks were selected trough surface microhardness (SMH) and were subjected to a pH cycling during 7 days. The treatment was done twice daily for 1 min with dentifrice containing 500 mgF/g. The sodium trimetaphosphate (TMP) concentration varied from 0 up to 3%. For the control groups, a dentifrice without F and P and a Gold Standard dentifrice (1100 mgF/g) were used. After the pH cycling, the percentage change of surface microhardness (%SMH), mineral loss (_Z) and the assessment of F, calcium and phosphate in enamel were calculated. Parametrical and non-parametrical tests and Pearsonþs correlation analysis were used to determine difference (p<0.05) and dose-response relationship between treatments. The results showed that TMP addition (from 0.25 to 3%) to a dentifrice without F induces a reduction in %SMH and _Z. When this concentration of TMP is added to a dentifrice with 500 mg F/g the final effect is similar to a dentifrice with 1100 mgF/g (CrestÔ). Also, the results showed an increase in the F content in lesion surface layer with the increase of TMP concentration. It is concluded that it is possible reduce the F content to 500 mgF/g by supplementing with phosphate and obtain a similar action when compared to a market dentifrice. / FAPESP: 05/54651-6
256

Avaliação da superfície do esmalte dentário por microscopia eletrônica de varredura após a remoção do bráquete e polimento

Pignatta, Lilian Maria Brisque [UNESP] 13 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-13Bitstream added on 2014-06-13T18:56:44Z : No. of bitstreams: 1 pignatta_lmb_me_araca.pdf: 865487 bytes, checksum: 83bd33e9257f262b5aff8eb76ff91ac1 (MD5) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / Introdução: a preservação da estrutura de esmalte após a remoção dos acessórios ortodônticos é uma obrigação do clínico. Portanto, procura-se um protocolo de descolagem com bases científicas. Objetivou-se neste trabalho avaliar por Microscopia Eletrônica de Varredura (MEV) a influência de quatro protocolos de remoção de bráquetes e polimento da superfície do esmalte e propor um protocolo que minimizasse os danos na superfície do esmalte. Material e método: doze incisivos permanentes bovinos foram divididos em quatro grupos de acordo com os instrumentos utilizados para a descolagem dos bráquetes e remoção do remanescente adesivo. Os bráquetes foram descolados com o alicate de descolagem reto (Ormco Corp.) nos grupos 1 e 2, e com o instrumento de descolagem Lift-Off (3M Unitek) nos grupos 3 e 4. Os remanescentes adesivos dos grupos 1 e 3 foram removidos com o alicate removedor de resina longo (Ormco Corp.) e dos grupos 2 e 4 com broca de carboneto de tungstênio (Beavers Dental) em alta-rotação com constante refrigeração de água. As superfícies, após cada etapa da descolagem e polimento, foram avaliadas em réplicas de resina epóxica e foram obtidas eletromicrografias com aumento de 50 e 200X em todos os grupos. Resultado: os quatro protocolos de remoção de acessórios ortodônticos e polimento ocasionaram irregularidades no esmalte. Conclusão: a remoção do bráquete com o alicate de descolagem reto, seguido da remoção do remanescente adesivo com broca de carboneto de tungstênio e polimento final com pasta de pedra-pomes foi o procedimento que ocasionou menores danos ao esmalte, sendo o protocolo sugerido para a remoção dos acessórios ortodônticos. / Introduction: the preservation of the enamel structure after the removal of the orthodontic accessories is an obligation of the clinical. Therefore, a protocol of debonding with scientific bases is searched. The aim of this work was to evaluate through Scanning Electronic Microscopy (SEM) the influence of four protocols of bracket s removal and polishing on the enamel and to recommend a protocol that minimized the damages to the enamel surface. Methods: twelve permanent bovine incisors were divided into four groups according to the instruments used to debond and remove of adhesive remnants. The brackets were removed with straight debonding pliers (Ormco Corp.) in the groups 1 and 2, and with Lift-Off debonding instrument (3M Unitek) in the Groups 3 and 4. The adhesive remnants in the groups 1 and 3 were removed with the adhesive removing pliers (Ormco Corp.) and in the groups 2 and 4 with high speed tungsten carbide bur with constant water refrigeration (Beavers Dental). The surfaces, after each step of debonding and polishing were evaluated in replicas of epoxy resin and were obtained electromicrographies with magnification of 50 and 200X in all groups. Results: the four removal protocols of orthodontic accessories and polishing caused irregularities to the enamel. Conclusion: the bracket s removal with straight debonding pliers, followed by the removal of the adhesive remnants with tungsten carbide bur and final polishing with pumice was the procedure that caused less damage to enamel, being the suggested protocol for removal of orthodontic accessories.
257

Ação do peróxido de hidrogênio 35% sobre a morfologia do esmalte e sua interferência do processo des-remineralização: estudo in situ

Arruda, Alex Mendez de [UNESP] 11 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-11Bitstream added on 2014-06-13T18:51:39Z : No. of bitstreams: 1 arruda_am_me_araca.pdf: 646025 bytes, checksum: 136184311e9ba76436388867a2d8dcc5 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho analisou in situ o efeito de um clareador a base de peróxido de hidrogênio a 35%, na microdureza superficial em esmalte bovino. Para tanto, 100 fragmentos dentais com dimensões de 4x4x2mm, foram polidos e submetidos à leitura inicial de microdureza Knoop. Foram selecionados os 44 fragmentos com microdureza mais próxima da mediana e estas unidades experimentais foram aleatoriamente divididas em grupos de 4 elementos que foram adaptados a aparelhos moveis usados por 11 indivíduos. Os voluntários foram orientados a utilizar o dispositivo durante todo o dia, com exceção dos momentos destinados à alimentação, higienização e às sessões clareadoras. Metade dos fragmentos de cada dispositivo foi submetida a uma sessão de clareamento (3 aplicações de 15 minutos) por semana, durante 14 dias, totalizando 3 sessões clareadoras. Os fragmentos não clareados permaneceram no dispositivo sem sofrer qualquer tipo de influência do clareador. Durante o uso do aparelho os fragmentos dentais foram submetidos ao acúmulo bacteriano, sendo gotejada uma gota da solução de sacarose a 20% em cada bloco, oito vezes ao dia, visando aumentar o desafio cariogênico. Após 7 dias, do término dos tratamentos foi realizada nova análise da microdureza e os valores foram submetidos à Análise de Variância ao nível de 5%. Pôde-se observar diminuição nos valores de microdureza, tanto para o grupo clareado (média: 238,9 – 179,4), quanto para o grupo controle (média: 237,3 – 191,7), sendo as médias mais baixas encontradas no grupo clareado. Concluiu-se que o tratamento clareador com peróxido de hidrogênio a 35% potencializou a redução da microdureza em dentes submetidos ao desafio cariogênico / This in situ study analyzed the effect of bleaching using 35% hydrogen peroxide on the enamel microhardness. Therefore, 100 dental fragments with dimensions of 4x4x2mm, were polished and subjected to the initial reading of microhardness. We selected 44 fragments presenting microhardness data similar to the mean value and these experimental units were randomly divided into groups of four elements that have been adapted in mobile devices to be worn by 11 volunteers. They were instructed to use the device throughout the day, except in meal times, cleaning and whitening sessions. Bleaching procedures were performed in half of the fragments placed on each device (3 applications of 15 minutes) per week for 14 days, totalizing 3 whitening sessions. Unbleached fragments remained on the device without suffering any kind of influence of the bleaching agent. While using the appliance, dental fragments were lead to bacterial colonization; sine a 20% sucrose solution was dripped eight times a day, aiming to increase the cariogenic challenge. After seven days of the end of the treatment, microhardness \analysis was performed. Data were submitted to ANOVA and Fisher's test at 5%. It was observed a decrease in microhardness values for both bleached group (mean: 238.9 to 179.4) and control group (mean: 237.3 to 191.7), besides that, the lowest values were verified in the bleached groups. It was concluded that bleaching using 35%hydrogen peroxide potentiated the reduction in microhardness in teeth submitted to cariogenic challenge
258

Resistência adesiva de sistemas autocondicionante e convencional frente a diferentes substratos e associação ao laser Nd:YAG: estudo in vitro

Marimoto, Ângela Regina Kimie [UNESP] 26 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-26Bitstream added on 2014-06-13T20:51:29Z : No. of bitstreams: 1 marimoto_ark_me_sjc.pdf: 390443 bytes, checksum: d76f9139d735bc954e3a1f9a3c6ec8ce (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A adesão continua a ser um desafio na Odontologia, principalmente em tecidos morfologicamente distintos e valendo-se de sistemas adesivos de mecanismos de ação também distintos. O objetivo deste estudo in vitro foi comparar a resistência adesiva de dois sistemas (autocondicionante e convencional) em dois substratos (esmalte e dentina), associados ou não à tecnologia laser (Nd:YAG). Foram utilizados 120 dentes bovinos, recém-extraídos, embutidos, que tiveram a superfície de esmalte ou dentina exposta por meio de lixas. Uma área de 3mm de diâmetro na região cérvico-vestibular-mediana foi selecionada para adesão, de acordo com os seguintes grupos: a) G1: AF/ esmalte (adesivo autocondicionante em esmalte seguindo especificação do fabricante); b) G2: AF/ dentina (adesivo autocondicionante em dentina seguindo especificação do fabricante); c) G3: AL/ esmalte (adesivo autocondicionante em esmalte + laser Nd:YAG + fotopolimerização); d) G4: AL/ dentina (adesivo autocondicionante em dentina + laser Nd:YAG + fotopolimerização); e) G5: CF/ esmalte (condicionamento ácido + adesivo convencional em esmalte); f) G6: CF/ dentina (condicionamento ácido + adesivo convencional em dentina); g) G7: CL/ esmalte (condicionamento ácido + adesivo convencional em esmalte + laser Nd:YAG + fotopolimerização); h) G8: CL/ dentina (condicionamento ácido + adesivo convencional em dentina + laser Nd:YAG + fotopolimerização). A resina composta Z 250 foi inserida com auxílio de matriz de teflon e fotopolimerizada com luz halógena, seguida da realização do teste de cisalhamento em máquina universal Emic, com carga de100kgf e velocidade de 0,5mm/min. Os valores médios em MPa obtidos para os diferentes grupos foram: G1 (20,291), G2 (14,142), G3 (23,615), G4 (22,235), G5 (20,899), G6 (11,291), G7 (22,102), G8 (15,980). Após aplicação do teste de ANOVA e Tukey 5%, concluiu-se que... / Bonding continues to be a challenge in Dentistry, particularly in morphologically different tissues, and adhesive systems with different action mechanisms are also valid. The aim of this study was to compare the bond strength of two systems (self-etching and conventional) to two substrates (enamel and dentin) either associated with laser technology (Nd:YAG) or not. One hundred and twenty (120) recently extracted, embedded bovine teeth were used, and abrasive papers were used to expose the enamel or dentin surfaces. An area of 3mm in diameter in the cervical-vestibular-median region was selected for bonding, according to the following groups: a) G1: AF/ enamel (self-etching adhesive to enamel in accordance with the manufacturer's specification); b) G2: AF/ dentin (self-etching adhesive to dentin in accordance with the manufacturer's specification); c) G3: AF/ enamel (self-etching adhesive to enamel + laser Nd:YAG + light polymerization ; d) G4: AL/ dentin (self-etching adhesive to dentin + laser Nd:YAG + light polymerization ; e) G5: CF/ enamel (acid etching + conventional adhesive to enamel); f) G6: CF/ dentin (acid etching + conventional adhesive to dentin); g) G7: CL/ enamel (acid etching + conventional adhesive to enamel + laser Nd:YAG + light polymerization ; h) G8: CL/ dentin (acid etching + conventional adhesive to dentin + laser Nd:YAG + light polymerization). Resin composite Z250 was inserted with the aid of a Teflon matrix and light polymerized, followed by the shear test in an EMIC universal machine, with a load of 100 Kgf and speed of 0.5 mm/min. The mean values obtained in Mpa for the different groups were: G1 (20.291), G2 (14.142), G3 (23.615), G4 (22.235), G5 (20.899), G6 (11.291), G7 (22.102), G8 (15.980). After applying the ANOVA and Tukey tests 5%, it was concluded that the application of laser Nd:YAG significantly increased the bond strength under all the experimental... (Complete abstract click electronic access below)
259

Avaliação dos efeitos causados por diferentes sistemas de clareamento dental sobre a estrutura superficial do esmalte e resina composta restauradora

Daniel, Carolina Pratti [UNESP] 08 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-08Bitstream added on 2014-06-13T19:51:22Z : No. of bitstreams: 1 daniel_cp_me_arafo.pdf: 928206 bytes, checksum: 591da8085d6b598e522141b55ce7e48c (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo deste estudo foi avaliar as alterações de microdureza, rugosidade e morfologia superficial do esmalte e da resina composta após diferentes técnicas de clareamento dental. Para isto, incisivos bovinos foram selecionados, sendo confeccionadas cavidades padronizadas na face vestibular, as quais foram restauradas com resina composta. Os dentes foram distribuídos em grupos (n=6), de acordo com o tratamento proposto: G1- clareamento com gel de peróxido de carbamida (PC) 10%; G2 - clareamento com gel contendo 38% peróxido de hidrogênio (PH); G3- clareamento com gel contendo 38% de PH associado à irradiação com luz. Para G1, o agente clareador foi aplicado por 8 horas diárias durante 21 dias. Para G2 e G3, foram realizadas 3 sessões, compostas por 3 aplicações do gel clareador por 15 minutos, com intervalos de 7 dias entre as sessões, sendo que em G3 foi aplicada luz LED (470nm) por 6 minutos. Durante o intervalo das aplicações do gel clareador, todos os espécimes foram armazenados em saliva artificial. A microdureza Knoop do esmalte e da resina composta foi avaliada antes do procedimento clareador e nos períodos de 1, 7, 14 e 21 dias pós-clareamento. A rugosidade superficial foi analisada por meio de um rugosímetro e a morfologia superficial por um microscópio de força atômica. Os dados foram analisados pelos testes de Mann-Whitney e Wilcoxon. Observou-se diminuição significante na dureza do esmalte para G2 e G3 após a 2ª e 3ª sessões, respectivamente, em relação à dureza inicial (p<0,05). Para a resina composta, esta alteração foi observada em G1 apenas após 21 dias, e em G2 e G3 após a 3ª sessão (p<0,05). Alterações significantes na rugosidade e morfologia superficial foram observadas apenas para o esmalte do grupo G1 (p<0,05). Concluiu-se que o gel com 10% de PC... / The aim of this study was to evaluate changes in microhardness, roughness and surface morphology of enamel and composite resin after different techniques of tooth bleaching. Standardized cavities prepared on the buccal surface of bovine incisors were restored with composite resin. The teeth were divided into groups (n=6) according to the following treatments: G1 - bleaching with 10% carbamide peroxide (CP) gel; G2 - bleaching with 38% hydrogen peroxide (HP) gel; G3 - bleaching with 38% PH gel associated to light irradiation. In G1, the whitening agent was applied for 8 hours daily during 21 days. In G2 and G3, three sessions characterized by three applications of bleaching gel for 15 minutes, with intervals of 7 days between sessions were performed. In G3, the bleaching gel was irradiated with LED (470nm) for 6 minutes. During the intervals among applications of the bleaching gel on enamel, all specimens were stored in artificial saliva. The Knoop microhardness of enamel and composite resin was evaluated before the bleaching procedure and at 1, 7, 14 and 21 days after this treatment. The roughness and superficial morphology (atomic force microscope) were evaluated before and at 21 days after the bleaching procedure. Data were analyzed by Mann-Whitney and Wilcoxon statistical tests. It was observed a significant decrease in hardness of enamel to G2 and G3 after the 2nd and 3rd bleaching sessions, respectively, when compared to the initial enamel hardness (p <0.05). For composites, this change was only observed in G1 after 21-day treatment, and in G2 and G3 after the third bleaching session (p <0.05). Significant changes in roughness and surface morphology of enamel was observed only in G1 (p <0.05). According to the experimental conditions, it was possible to conclude that the bleaching gel with... (Complete abstract click electronic access below)
260

Rugosidade superficial do esmalte e de resinas compostas: avaliação de instrumentos de acabamento pelo microscópio de força atômica

Oliveira, Ana Carolina Botta Martins de [UNESP] 26 February 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-02-26Bitstream added on 2014-06-13T18:51:42Z : No. of bitstreams: 1 oliveira_acbm_me_arafo.pdf: 4311802 bytes, checksum: 1f571cd42db44ab09a36226da7dcd075 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito de instrumentos de acabamento e técnicas de polimento sobre a rugosidade superficial de resinas compostas e comparar ao esmalte humano íntegro, através do Microscópio de Força Atômica (MFA). Superfícies planas de face vestibular de quatro incisivos centrais superiores humanos hígidos foram usadas para análise da rugosidade superficial do esmalte. Resinas compostas nanoparticulada (Filtek Supreme XT, 3M ESPE), microhíbrida (Point 4, Kerr Corp.), híbrida (tetric Ceram, Ivoclar Vivadent) e microparticulada (Durafill VS, Heraeus Külzer) foram avaliadas. Todas as amostras de resinas compostas foram confeccionadas sob uma tira de poliéster. Os procedimentos de acabamento superficial foram realizados com uma fresa carbide de 30 lâminas e uma ponta diamantada de 30 æm nas amostras de resinas compostas nanoparticulada e microhíbrida. Quatro técnicas de polimento (TO : Matriz de poliéster - controle: T1 : discos de óxido de alumínio; T2 : disco de feltro + pasta diamantada) foram testadas em todas as amostras de resinas compostas. Nrugosidade média superficial (Ra) foi avaliada pelo MFA no modo contato. Os dados obtidos foram submetidos ao Teste t de Student, á análise de variância e ao Teste de Tukey, ao nível de 5% de significância. A maior lisura superficial foi obtida com a matriz de poliéster para Filttek Supreme XT (Ra=23,63nm), Point 4 (Ra=12,84nm) e Tetric Ceram (Ra=15,20nm). Aresina Durafill VS foi menos rugosa com os discos de óxido de alumínio (Ra=43,05nm). A maior rugosidade superficial foi obtida com a ponta diamantada para Filek Supreme XT (Ra=510,55nm) e Point 4 (Ra=531,64nm), sem diferença estatisticamente significante entre elas. A rugosidade superficial do esmalte foi de 46,55 nm. Com base nestes resultados põde-se concluir que a rugosidade superficial aumentou significamente... / The aim of this study was to assess the effect of finishing instruments and of polishing techniques on surface roughness of composite resins and to compare to intact human enamel through Atomic Force Microscope (AFM). Flat buccal surface of four caries-free human maxillary central incisors were used for the roughness analysis of enamel. Nanofiller (Filtek Supreme XT, 3M ESPE), microhubrid (Point 4, Kerr Corp.), hybrid (tetric Ceram, Ivoclar Vivadent) and microfilled Durafill V.S., Heraeus Külzer) composite resins were evaluated. Mylar matrix strip was used as control group for both analyses. Finishing procedures were done with a 30-blade carbide bur and 30 æm finishing diamond ur for nanofiller and microhybrid resins. Four polishing techniques weretested (T0 : Mylar matrix - control; T1: aluminium oxide discs; T2: felt disc+ diamond paste; T3: aluminium oxide discs + felt disc + diamond paste in all composite resins. The mean roughness (Ra) was evaluaed under AFM on the contact mode. The obtained data was submitted to Studentþs t test, variance , variance analysis (ANOVA) and, Tukeyþs Test, at 5% level of significance. The smoothest surface was obtained with ylar matrix associated with Filtek Supreme XT (Ra=23,63nm), Point 4 (Ra=12,84nm) and Tetric ceram (Ra=15,20nm). Durafill VS showed the lowest roughness with aluminium oxide discs (Ra=43,05nm). The highest surface eoughness was obtained with diamond bur for Fittek Supreme XT (Ra=510,55nm) and point 4 (Ra=531,64nm), without significant difference between them. Surface roughness of enamel was of 46,55nm. Roughness increased significantly after fishing procedures. 30-blade carbide bur produced less roughness compared to extra fine diamond bur. Diamond paste also increased the roughness of composites. Aluminium oxide discs may be used as standard polishing technique for all composite resins, except for hybrid... (Complete abstract, click electronic access below)

Page generated in 0.0578 seconds