• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • Tagged with
  • 128
  • 128
  • 128
  • 38
  • 37
  • 36
  • 35
  • 26
  • 23
  • 23
  • 21
  • 20
  • 20
  • 19
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação in vitro da difusão de íons Ca+2 e OH- de materiais endodônticos em dentes decíduos

Nunes, Ana Cristina Gerent Petry January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-21T03:14:01Z (GMT). No. of bitstreams: 1 200126.pdf: 1191399 bytes, checksum: 268151a00b86c4e8297b26e2267301ef (MD5) / O objetivo desta pesquisa foi avaliar a difusão de íons Ca+2 e OH- de materiais endodonticos através da raiz intacta de dentes decíduos. Todos os dentes foram instrumentados em seu comprimento de trabalho até a lima # 40, irrigados com solução de hipoclorito de sódio 1%, e secos com cones de papel absorvente. Os materiais utilizados como obturadores foram: pasta de Ca(OH)2 associada ao propilenoglicol espessada (CaPE); pasta UFSC, mistura de de pó de óxido de zinco com pó de Ca(OH)2 associado ao óleo de oliva; Vitapex ® e Sealapex ®. Após a obturação, todos os dentes tiveram o terço apical e coronal selados, e permaneceram em frascos individuais com solução fisiológica. A análise da difusão de íons OH- e Ca+2 foi realizada por meio de um pHmetro calibrado e um espectrômetro de absorção atômica, respectivamente em 48h, 7, 30, 45 e 60 dias. A pasta CaPE foi o material obturador que mais difundiu íons OH- e Ca+2.
32

Desenvolvimento de métodos para a determinação de mercúrio e tálio em amostras ambientais usando GF AAS e ETV-ICO-MS

Silva, Alessandra Furtado da January 2004 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química. / Made available in DSpace on 2012-10-21T17:35:42Z (GMT). No. of bitstreams: 1 204136.pdf: 947494 bytes, checksum: 8d45a223926fb8b99323ef00e885e939 (MD5) / Métodos para a determinação de mercúrio e tálio em amostras ambientais por GF AAS e ETV-ICP-MS foram desenvolvidos, usando a análise direta de sólidos e suspensão. Foram investigados modificadores permanentes como irídio, paládio, ródio e rutênio para a determinação de mercúrio em materiais certificados: cinza, esgoto, sedimento marinho e sedimento de rio, usando a GF AAS com amostragem sólida. O desempenho do paládio foi o mais consistente, tendo a massa característica como o maior critério. Uma quantidade de mercúrio foi perdida da solução aquosa durante a etapa de secagem, e essa perda pode ser contornada após a adição de permanganato de potássio, que finalmente tornou possível o uso de calibração com padrões aquosos para a análise direta de sólidos. Os resultados obtidos para mercúrio foram satisfatórios para um procedimento de rotina, apresentando um limite de detecção de 0,2 mg kg-1. Foi proposto também um método para a determinação de mercúrio e tálio em amostras ambientais usando a ETV-ICP-MS com amostragem por suspensão. O permanganato de potássio em solução, bem como o potássio e o manganês em solução, foram estudados como modificadores e carreadores. A melhor sensibilidade e estabilização térmica foram obtidas com permanganato de potássio em um tubo não tratado, especialmente para tálio. A exatidão do método foi confirmada pela análise de oito materiais certificados, usando calibração externa com padrões aquosos preparados da mesma maneira que as suspensões. Os limites de detecção nas amostras foram 0,18 mg g-1 para Hg e 0,07 mg g-1 para tálio. A precisão encontrada para as diferentes amostras, como desvio padrão relativo, foi de 0,8-11 % para mercúrio e 1-9% para tálio (n = 3). O último desenvolvimento de método foi a determinação de tálio usando a GF AAS de alta resolução com fonte contínua. Os resultados obtidos sem modificador, com paládio adicionado em solução e rutênio como modificador permanente, para 11 amostras de carvão e uma de cinza de carvão foram concordantes, com um nível de confiança de 95%, usando calibração com padrões aquosos. A precisão, como desvio padrão relativo, foi melhor que 5% e o limite de detecção foi de 0,01 mg g-1 de tálio.
33

Otimização do método para determinação de boro em fritas e minérios utilizando a técnica de espectrometria de absorção atômica por chama

Carvalho, Maria Degmar dos Reis January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Ciência e Engenharia dos Materiais. / Made available in DSpace on 2012-10-20T01:35:58Z (GMT). No. of bitstreams: 1 220826.pdf: 19040966 bytes, checksum: 63bcd3cf4800d5d91b3480b328e6c228 (MD5)
34

Amostragem em suspensão de sedimentos, carvões e cinzas para a determinação de As e Sn por HG - GF AAS com retenção no tubo de grafite recoberto com modificador permanente

Vieira, Mariana Antunes January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química. / Made available in DSpace on 2012-10-20T14:35:21Z (GMT). No. of bitstreams: 1 198725.pdf: 715675 bytes, checksum: f743f8056c3e90ce0abe49e7f06016f6 (MD5) / Uma metodologia simples, eficiente e reprodutível é proposta para a determinação de As e Sn em amostras de interesse ambiental, fazendo uso da amostragem em suspensão e determinação por HG-GF AAS. Na otimização do preparo das suspensões, condições como concentração de ácidos, tempo de repouso e tamanho da partícula foram estudados. Os principais parâmetros do sistema de geração químico de vapor como concentração de agente redutor, volume de injeção de amostra e tempo de reação foram avaliados. Os programas de temperatura do forno de grafite para as determinações de As e Sn foram otimizados para cada tipo de modificador permanente. No caso específico do Sn, avaliaram-se três modificadores permanentes (Th, W e Ir) para a retenção dos analitos na superfície do tubo de grafite, enquanto para o As somente se utilizou o Ir. Para ambos os analitos, duas metodologias de calibração foram testadas: a convencional com soluções padrão aquosas e a técnica de calibração por adição. A metodologia desenvolvida para a determinação de As foi validada pela análise de 11 materiais de referência certificada. Boa concordância com os valores certificados foi obtida, quando se utilizou o método da calibração por adição. Para o Sn, a exatidão foi avaliada pela análise de 8 materiais de referência certificados. Usando a calibração externa convencional, resultados concordantes com os valores certificados, somente foram obtidos para as amostras de sedimento. Para os carvões, foi necessário usar a calibração por adição. O método também foi aplicado na análise de 4 sedimentos coletados em diferentes pontos da região costeira da Ilha de Santa Catarina.
35

Desenvolvimento de método de determinação de cálcio, magnésio e zinco em amostras de óleo lubrificante por espectrometria de absorção atômica com chama

Zmozinski, Ariane Vanessa January 2010 (has links)
Neste trabalho foi desenvolvido um método para a determinação de Ca, Mg e Zn em óleos lubrificantes e quantificação por Espectrometria de Absorção Atômica com Chama (F AAS). As amostras foram diluídas com uma pequena quantidade de querosene de aviação (QAV), propanol e água formando uma solução de três componentes. Para a calibração, foram utilizados padrões inorgânicos aquosos. Para a avaliação da exatidão do método desenvolvido foi utilizado a norma ABNT NBR 14066, que consiste na diluição das amostras com QAV e quantificação por F AAS. Dois outros métodos para avaliar a exatidão foram empregados: digestão ácida e análise de material de referência certificado NIST (SRM 1084a). O método proposto apresentou as seguintes vantagens quando comparado com o método de referência: significativa redução do uso de QAV, maior estabilidade dos analitos no meio, utilização de padrões inorgânicos aquosos na calibração. Os valores dos limites de detecção para o Ca, Mg e Zn foram 1,3 μg g-1, 0,052 μg g-1 e 0,41 μg g-1 respectivamente. O método desenvolvido foi aplicado para amostras reais e os resultados foram concordantes com os obtidos pelos métodos de referência. / Lubricating oils are used to decrease wear and friction of movable parts. The presence of metals such as Ca, Mg and Zn show the addition of specific additives that improve the performance of these lubricants. In this work, a method for determination of Ca, Mg and Zn in lubricating oil by flame atomic absorption spectrometry (F AAS) was developed. The samples were diluted with a small quantity of aviation kerosene (AVK), n-propanol and water to form a three component solution before its introduction in the F AAS. Aqueous inorganic standards diluted in the same way have been used for calibration. To assess the accuracy of the new method, the comparison with the ABNT NBR 14066 standard method, which consist in diluting the sample with AVK and quantification by F AAS, was employed. Two other methods to evaluate the accuracy have also been used: the acid digestion method and the certified reference material NIST (SRM 1084a). The proposed method provides the following advantages when compared with the standard method: significant reduction of the use of AVK, higher stability of the analytes in the medium and application of aqueous organic standards for calibration. The limits of detection for Ca, Mg and Zn were 1.3 μg g-1, 0.052 μg g-1 and 0.41 μg g-1 respectively. The proposed method was applied to real samples and the results were consistent with those obtained by reference methods.
36

Uso de modificadores químicos permanentes na determinação de cádmio em suspensão de carvão por GF AAS convencional e de alta resolução

Bianchin, Liane January 2005 (has links)
Irídio e rutênio isoladamente e em combinação com tungstênio, termicamente depositados na plataforma de um tubo de grafite com aquecimento transversal, foram investigados quanto a sua aplicabilidade como modificadores permanentes para a determinação de cádmio em suspensões de carvão por espectrometria de absorção atômica com forno de grafite. O modificador químico de Pd-Mg adicionado em solução na forma de nitratos também foi investigado, para comparação. Este apresentou a melhor performance para solução aquosa, enquanto a mistura de W-Ir e W-Ru como modificadores permanentes apresentou o menor poder de estabilização. Todos os modificadores investigados perdem parte do seu poder de estabilização quando aplicados a suspensões de carvão. O modificador químico Pd-Mg e os modificadores permanentes Ir e Ru bem como a mistura de 300 μg de W e 200 μg de Ir estabilizam cádmio a uma temperatura de pirólise de 600 ºC, enquanto que as demais combinações investigadas permitem temperaturas de pirólise máximas entre 500 e 550 ºC. Investigações a partir da fase líquida das suspensões demonstram que existe a possibilidade de que a alta concentração de ácido empregada no preparo das suspensões e/ou compostos que são extraídos do carvão para a fase líquida podem ser responsáveis pela redução no poder de estabilização dos modificadores. A temperatura máxima de pirólise de 600 ºC não foi suficiente para reduzir a absorção de fundo provocada por concomitantes de algumas das amostras testadas, enquanto que temperaturas de pirólise mais elevadas levam à perda de analito. Para o desenvolvimento deste estudo, foram utilizados os materiais de referência BCR No 180 Gas Coal, SARM 18 Coal Witbank, SARM 19 Coal O.F.S., SARM 20 Coal Sasolburg, NIST SRM 1635, NIST SRM 1630a e SRM 1632b. Foi investigado também um carvão brasileiro da mina de Candiota no Rio Grande do Sul. Foram determinadas as figuras de mérito e os valores obtidos para o limite de detecção e a massa característica estão entre 1,0 e 1,3 ng g-1 e 1,9 e 2,2 pg, respectivamente. Estudos por espectrometria de absorção atômica de alta resolução com fonte contínua foram realizados com o intuito de elucidar as possíveis interferências provenientes de diferentes matrizes de carvão na forma de suspensão. Estes estudos revelaram que o fundo contínuo apresenta uma absorção maior do que a capacidade de correção exibida pelo corretor de deutério e que o mesmo se sobrepõe ao sinaldo analito. Valores de 1,0 pg e 0,6 ng g-1 foram obtidos respectivamente, para massa característica e limite de detecção, empregando-se irídio como modificador permanente e temperatura de pirólise de 600 ºC. Apesar de a técnica corrigir esse fundo pronunciado, parte do analito é aparentemente perdida durante a volatilização da matriz, fazendo com que o método não possa ser considerado robusto. / Iridium and ruthenium, alone and in combination with tungsten, thermally deposited on the platform of a transversely heated graphite tube, were investigated for their suitability as permanent chemical modifiers for the determination of cadmium in coal slurries by graphite furnace atomic absorption spectrometry (GF AAS). The conventional mixed palladium and magnesium nitrates (Pd-Mg) modifier, added in solution, was also investigated for comparison. The latter one showed the best performance for aqueous solutions, and the mixed W-Ir and W-Ru permanent modifiers had the lowest stabilizing power. All of the investigated modifiers lost some of their stabilizing power when coal slurries were investigated. The Pd-Mg modifier, pure Ir and Ru, and a mixture of 300 μg W + 200 μg Ir could stabilize Cd at least to a pyrolysis temperature of 600 ºC, whereas all the other combinations already failed at temperatures above 500-550 ºC. Additional investigations of the supernatant liquid of the slurries supported the assumption that the high acid concentration of the slurries and/or a concomitant leaching out of the coal might be responsible for the reduced stabilizing power of the modifiers. The maximum applicable pyrolysis temperature of 600 ºC was not sufficient to reduce the background absorption to a manageable level in the majority of the coal samples and higher pyrolysis temperatures cause loss of analyte. The following reference materials were used in this work: BCR No. 180 Gas Coal, SARM 18 Coal witbank, SARM 19 Coal O.F.S, SARM 20 Coal Sasolburg, NIST SRM 1635, NIST SRM 1630a and SRM. In addition, a coal sample from the Candiota mine in Rio Grande do Sul, Brazil, was investigated. Figures of merit were established and the values obtained for detection limit and characteristic mass were between 1.0 and 1.3 ng g-1 and 1.9 and 2.2 pg, respectively. In order to further investigate the spectral interference caused by the coal slurries, additional investigations were carried out using high resolution continuum source atomic absorption spectrometry. High-resolution continuum source ET AAS revealed that the continuous background absorption was beyond the capabilities of background correction exhibit by the deuterium background correction system, and was overlapping with the analyte signal. A characteristic mass of 1.0 pg and a detection limit of 0.6 ng g-1 could be obtained with iridium as permanent modifier and a pyrolysis temperature of 600 ºC. Although the technique could correct for thisbackground absorption, some analyte was apparently lost with the rapidly vaporizing matrix so that the method could not be considered to be rugged.
37

Desenvolvimento de método de determinação de cálcio, magnésio e zinco em amostras de óleo lubrificante por espectrometria de absorção atômica com chama

Zmozinski, Ariane Vanessa January 2010 (has links)
Neste trabalho foi desenvolvido um método para a determinação de Ca, Mg e Zn em óleos lubrificantes e quantificação por Espectrometria de Absorção Atômica com Chama (F AAS). As amostras foram diluídas com uma pequena quantidade de querosene de aviação (QAV), propanol e água formando uma solução de três componentes. Para a calibração, foram utilizados padrões inorgânicos aquosos. Para a avaliação da exatidão do método desenvolvido foi utilizado a norma ABNT NBR 14066, que consiste na diluição das amostras com QAV e quantificação por F AAS. Dois outros métodos para avaliar a exatidão foram empregados: digestão ácida e análise de material de referência certificado NIST (SRM 1084a). O método proposto apresentou as seguintes vantagens quando comparado com o método de referência: significativa redução do uso de QAV, maior estabilidade dos analitos no meio, utilização de padrões inorgânicos aquosos na calibração. Os valores dos limites de detecção para o Ca, Mg e Zn foram 1,3 μg g-1, 0,052 μg g-1 e 0,41 μg g-1 respectivamente. O método desenvolvido foi aplicado para amostras reais e os resultados foram concordantes com os obtidos pelos métodos de referência. / Lubricating oils are used to decrease wear and friction of movable parts. The presence of metals such as Ca, Mg and Zn show the addition of specific additives that improve the performance of these lubricants. In this work, a method for determination of Ca, Mg and Zn in lubricating oil by flame atomic absorption spectrometry (F AAS) was developed. The samples were diluted with a small quantity of aviation kerosene (AVK), n-propanol and water to form a three component solution before its introduction in the F AAS. Aqueous inorganic standards diluted in the same way have been used for calibration. To assess the accuracy of the new method, the comparison with the ABNT NBR 14066 standard method, which consist in diluting the sample with AVK and quantification by F AAS, was employed. Two other methods to evaluate the accuracy have also been used: the acid digestion method and the certified reference material NIST (SRM 1084a). The proposed method provides the following advantages when compared with the standard method: significant reduction of the use of AVK, higher stability of the analytes in the medium and application of aqueous organic standards for calibration. The limits of detection for Ca, Mg and Zn were 1.3 μg g-1, 0.052 μg g-1 and 0.41 μg g-1 respectively. The proposed method was applied to real samples and the results were consistent with those obtained by reference methods.
38

Desenvolvimento de método analítico para determinação de metais em biodiesel e óleo vegetal por espectometria de absorção atômica com chama

Jesus, Alexandre de January 2008 (has links)
Os metais sódio, potássio, magnésio e cálcio podem danificar a estabilidade do biodiesel, pois tendem a reagir com ésteres e produzir sabão. Neste trabalho foi desenvolvido um método para a determinação desses metais em amostras de biodiesel e óleo vegetal, através da microemulsificação das amostras e determinação por espectrometria de absorção atômica com chama (F AAS). Amostras de biodiesel obtidas de diferentes fontes e de óleo vegetal foram analisadas. Foram obtidas microemulsões do tipo óleo-em-água pela mistura de biodiesel ou óleo vegetal, um surfactante, água e um co-surfactante. Na fase aquosa das microemulsões, foram adicionados HNO3 diluído e padrões inorgânicos dos metais para calibração. Vantagens em relação ao método de diluição com solvente, que é o método oficial adotado para as determinações (método de referência) foram observadas, tais como: maior estabilidade dos analitos no meio microemulsificado, possibilidade de calibração usando padrões aquosos nas microemulsões, limites de quantificação melhores e não utilização de solventes orgânicos carcinogênicos. Os resultados obtidos pelo método proposto foram concordantes com os resultados obtidos pelo método de referência, tornando assim o novo método uma eficiente alternativa para a determinação de metais em biodiesel, além de suprir as deficiências apresentadas pelo método de diluição com solvente. / The metals sodium, potassium, magnesium and calcium can damage biodiesel stability because these metals tend to react with esters and produce soap. In this work a method was developed for the determination of these metals in biodiesel and vegetable oil samples, through microemulsification of the samples and determination by flame atomic absorption spectrometry (F AAS). Biodiesel samples obtained from different sources and vegetable oil samples were analyzed. The water-in-oil microemulsion systems were obtained mixing biodiesel, a surfactant, water and a co-surfactant. Inorganic standards were added within the water portion to prepare the microemulsions used for calibration and nitric acid. The proposed method was compared with the method adopted by Brazilian’s regulations of dilution with organic solvent (reference method) for these determinations and some advantages were observed, as: higher stability of analytes in the microemulsions, feasibility of calibration using aqueous standards in the microemulsions, better limits of quantification and no use carcinogenic solvents. The results obtained by the new proposed method were a good agreement with the results obtained by the reference method. The new proposed method was an efficient alternative for the determination of metals in biodiesel, and overcome some deficiencies presented by the dilution method.
39

Desenvolvimento de métodos analíticos para a determinação de mercúrio e selênio utilizando técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite

Potes, Mariana da Luz January 2018 (has links)
A geração química de vapor (CVG) e a geração fotoquímica de vapor (PVG) são técnicas analíticas empregadas na conversão do analito, presente na fase condensada, em uma espécie volátil, previamente a sua introdução no sistema de detecção. Neste trabalho foram desenvolvidos procedimentos analíticos para a determinação de Hg e Se em amostras biológicas por técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite (GF AAS). A determinação exata e precisa de Hg em amostras de peixe foi possível após a solubilização em hidróxido de tetrametilamônio e adição de n-propanol, como composto orgânico de baixo peso molecular, e detecção por PVG-GF AAS. O método analítico desenvolvido com o emprego da técnica de PVG para a determinação de Se em água de coco por GF AAS resultou em limites de detecção e quantificação de 0,65 μg L-1 e 2,2 μg L-1, respectivamente, os quais foram semelhantes aos obtidos por CVG. Os métodos desenvolvidos para a determinação de Hg e Se por PVG-GF AAS em amostras biológicas são sensíveis, livres de interferência espectral, de baixo custo e representam uma alternativa viável a CVG. / Chemical vapor generation (CVG) and photochemical vapor generation (PVG) are analytical techniques used to convert the analyte into a volatile species in liquid phase, before the introduction into the detection system. In this study, analytical procedures for the determination of Hg and Se in biological samples by vapor generation techniques coupled to graphite furnace atomic absorption spectrometry (GF AAS) were developed. Accurate Hg determination in fish samples was possible after a solubilization in tetramethylammonium hydroxide and adding n-propanol, as low molecular organic compound, using PVG-GF AAS. The developed method for Se determination in coconut water with PVG-GF AAS have resulted in limits of detection and quantification of 0,65 μg L-1 and 2,2 μg L-1, respectively and that were similar with those obtained with CVG. The developed methods for Hg and Se determination in biological samples using PVG-GF AAS are sensitive, free of spectral interference, low-cost, and are a feasible alternative for CVG.
40

Estratégias analíticas para determinação sequencial de metais em vinhos por espectrometria de absorção atômica de alta resolução com fonte contínua por chama

Boschetti, Wiliam January 2012 (has links)
Neste trabalho foi desenvolvido e otimizado um método para determinação sequencial rápida por espectrometria de absorção atômica de alta resolução com fonte contínua por chama (HR-CS FS-FAAS) de metais em amostras de vinhos, produzidos em diferentes regiões do Brasil. As amostras foram obtidas de 8 regiões brasileiras diferentes: Serra Gaúcha, Vale dos Vinhedos, Pinto Bandeira, Campos de Cima da Serra, Campanha Gaúcha, Serra Catarinense, Oeste do Paraná e Vale do São Francisco. Os elementos avaliados foram: Be, Ca, Co, Cu, K, Li, Mn, Na, Rb e Sr. Estes metais têm grande importância nas propriedades organolépticas do vinho, assim como para produção de uvas de qualidade. A validação do método foi feita pelo estabelecimento de curvas de calibração, realização de ensaios de recuperação e comparação dos resultados encontrados por HR-CS FS-FAAS com aqueles obtidos por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). Padrões aquosos foram utilizados para a calibração e o coeficiente de correlação encontrado, para todos os analitos avaliados, foi maior que 0,9994. A partir das curvas de calibração os limites de detecção foram calculados para cada elemento: 44 μg L-1 para Cu, 5,0 μg L-1 para Li, 20 μg L-1 para Rb, 42 μg L-1 para Mn, 58 μg L-1 para Co, 15 μg L-1 para Sr, 23 μg L-1 para Be, 0,90 mg L-1 para Na, 4,4 mg L-1 para K e 0,92 mg L-1 para Ca. Ensaios de recuperação para cada analito foram realizados, encontrando recuperações entre 91 e 111%. A partir dos resultados encontrados, fazendo-se uso das técnicas de reconhecimento de padrões Análise por Componentes Principais (PCA) e Análise por Agrupamento Hierárquico (HCA) foi observada a formação de 7 grupos distintos, quando empregados os teores de K, Mn, Rb e Sr, dentre os 8 grupos (regiões do Brasil) avaliados. Com este conjunto de informações, portanto, é possível o monitoramento de fraudes e da qualidade do vinho produzido em cada região produtora. / In this work a method has been developed for the determination of metals in wine samples, produced in different regions of Brazil, using high-resolution continuum source fastsequential flame atomic absorption spectrometry (HR-CS FS-FAAS). The samples were obtained from eight different regions: Serra Gaúcha, Vale dos Vinhedos, Pinto Bandeira, Campos de Cima da Serra, Campanha Gaúcha, Serra Catarinense, Oeste do Paraná e Vale do São Francisco. The investigated elements were: Be, Ca, Co, Cu, K, Li, Mn, Na, Rb and Sr. These metals are important for the organoleptic properties of wine and for the production of grapes. The method was validated by recovery tests and comparison between the results obtained by HR-CS FS-FAAS and inductively coupled plasma optical emission spectrometry (ICP OES). Aqueous standards were used for calibration and the correlation coefficient found was higher than 0.9994 for all investigated elements. The detection limits were calculated from the calibration curves for each analyte: 44 μg L-1 for Cu, 5.0 μg L-1for Li, 20 μg L-1 for Rb, 42 μg L-1 for Mn, 58 μg L-1 for Co, 15 μg L-1 for Sr, 23 μg L-1 for Be, 0.90 mg L-1 for Na, 4.4 mg L-1 for K and 0.92 mg L-1 for Ca. The recovery tests showed results between 91 and 111%. After method validation the samples were evaluated. With the results obtained and using pattern recognition techniques Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) was possible to find seven different groups, evaluating K, Mn, Rb and Sr concentration values, among the eight original groups (Brazilian regions) evaluated. Finally, using all the information obtained in this work, it’s possible to control frauds and the wine produced quality.

Page generated in 0.3009 seconds