• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 104
  • 2
  • Tagged with
  • 106
  • 106
  • 62
  • 46
  • 46
  • 38
  • 33
  • 32
  • 30
  • 28
  • 26
  • 20
  • 18
  • 16
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Avaliação do uso de lodos de estação de tratamento de água como matéria-prima na confecção de tijolos cerâmicos: estudo de caso - ETA Bolonha

MULLER, Elzelis de Aguiar 26 June 2009 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2012-04-09T22:32:52Z No. of bitstreams: 2 Dissertacao_AvaliacaoUsoLodo.pdf: 5633870 bytes, checksum: 18cf173a3b562c94681dd7820fce0ac3 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Edisangela Bastos(edisangela@ufpa.br) on 2012-04-09T22:35:23Z (GMT) No. of bitstreams: 2 Dissertacao_AvaliacaoUsoLodo.pdf: 5633870 bytes, checksum: 18cf173a3b562c94681dd7820fce0ac3 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-04-09T22:35:23Z (GMT). No. of bitstreams: 2 Dissertacao_AvaliacaoUsoLodo.pdf: 5633870 bytes, checksum: 18cf173a3b562c94681dd7820fce0ac3 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2009 / O presente trabalho objetivou avaliar a possibilidade de incorporar o lodo da Estação de Tratamento de Água do Bolonha (RMB), na fabricação de tijolos cerâmicos para uso na construção civil. Duas unidades de desaguamento de lodo (UDL) foram implantadas e operacionalizadas na ETA Bolonha. Antes da confecção dos tijolos cerâmicos, o lodo da ETA Bolonha foi desaguado nas UDL’s que eram dotadas de manta permeável, e em seguida foram caracterizadas fisicamente e mineralogicamente. O lodo foi adicionado à massa cerâmica de uma indústria local para a produção de tijolos. Diversas proporções da mistura lodo e argila foram testadas com intuito de encontrar a proporção adequada para a produção de tijolos cerâmicos (10%, 12% e 20% de lodo de ETA à massa cerâmica). Ensaios de laboratório foram realizados para avaliar sua resistência, absorção de água, dimensões adequadas e aspecto visual. Não foi possível a incorporação de 20% de lodo à massa cerâmica devido à alta plasticidade e a dificuldade de fabricação dos tijolos cerâmicos, no entanto, as proporções de 10% e 12% de lodo de ETA foram as que tiveram resultados melhores quanto aos parâmetros de resistência, indicando que os tijolos cerâmicos podem ser produzidos com a incorporação de até 12% de lodo de ETA. / This study aimed to evaluate the possibility of incorporating the sludge in the water treatment station of Bolonha (RMB), in the manufacture of ceramic bricks for use in construction. Two units of flow of mud (UDL) were established and operationalized in the ETA Bolonha. Before the preparation of ceramic bricks, the mud flows were ETA Bologna in UDL's that were equipped with open collar, and then were characterized physically and mineralogically. The sludge was added to the ceramic body of a local industry for the production of bricks. Various proportions of silt and clay mixture were tested in order to find the appropriate proportion to the production of ceramic bricks (10%, 12% and 20% of sludge in the ceramic body ETA). Laboratory tests were conducted to assess its strength, water absorption, an appropriate size and visual appearance. It was not possible to incorporation of 20% of mud to ceramic body due to the high plasticity and the difficulty of manufacture of ceramic bricks, however, the proportions of 10% and 12% of sludge from ETA were the ones that had better results on the parameters of resistance, indicating that the ceramic bricks can be produced with the incorporation of up to 12% of sludge from ETA.
82

O balanço de massa das unidades componentes de uma estação de tratamento de esgoto e a utilização da estatística multivariada como ferramenta de verificação do comportamento físico, químico, bacteriólogico e de metais no esgoto bruto e tratado. Estudo de caso: estação de tratamento de esgoto doméstico – ETE Sideral - Belém - PA

FARIAS, Flavia da Silva 04 October 2013 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T12:36:56Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_BalancoMassaUnidades.pdf: 3176538 bytes, checksum: 17d2dc7e6c829993e2dc72066b1fb750 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-20T12:00:24Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_BalancoMassaUnidades.pdf: 3176538 bytes, checksum: 17d2dc7e6c829993e2dc72066b1fb750 (MD5) / Made available in DSpace on 2017-03-20T12:00:24Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_BalancoMassaUnidades.pdf: 3176538 bytes, checksum: 17d2dc7e6c829993e2dc72066b1fb750 (MD5) Previous issue date: 2013-10-04 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / O estudo sobre o Balanço de massa das unidades componentes de uma estação de tratamento de esgoto e a utilização da estatística multivariada como ferramenta de verificação do comportamento do esgoto bruto e tratado foi realizado na ETE Sideral no Munícipio de Belém Pará Brasil. Neste estudo foiobservado todo o fluxograma constituinte da estação que foi projetada para receber uma vazão máxima de esgoto bruto de 73 l/s., como em verificação local se constatou que a vazão para qual a estação foi projetada é consideravelmente menor o balanço de massa e todo o resto do estudo foi trabalhado em cima da vazão de projeto. Na verificação das partes físicas constituintes da estação verificaram-se não conformidades nas medidas que foram sugeridas no projeto executivo.Na caracterização dos metais presentes no esgoto bruto e tratado verificou-se que na Analisedas Componentes Principais o Boro (B) com (63,5%) e seguido do Bário (Ba) com (21,9%) justificam 84,48% o coeficiente de variação que os determinam como os metais predominantes no Afluente. No Efluente o Boro (B) apresentou um coeficiente de variação de 73,7% o que o justifica como sendo o principal componente no afluente da ETE. Na caracterização dos metais no lodo observou-se que com uma porcentagem de 98,8% o Bário (Ba) é o principal elemento encontrado. Os resultados obtidos com a análise de componentes principais para a caracterização físico-químicas e bacteriológicas do esgoto bruto e tratado da ETE observou-se que a variável ―DQO total‖ encontra-se positivamente relacionada com a componente DBO e negativamente correlacionado com a Alcalinidade Total. Em relação às características físico-químicas e bacteriológicas, elevados teores de DBO, Coliformes termotolerantes, SST e SSV, oriundos dos lançamentos dos efluentes domésticos, fazendo com que apresentassem as maiores concentrações de carga orgânica remanescente. / The mass balance of the component units of a wastewater sewage treatment and use of multivariate statistics as a tool for verifying the behavior of raw sewage and treated, was implemented in ETE Sidereal Municipality of Belem do Para in Brazil. This study observed the entire flowchart constituent of the station that is designed to receive a maximum flow of raw sewage of 73 l / s. and now serves a flow of only 1.7 l / so that decreases in 96% of the station was designed, realizing then that today the Sidereal ETE is oversized. In verifying the constituent physical parts of the station there were not in compliance measures that have been suggested in the executive project and were perceived as "in situ". In the mass held for three types of flows: maximum (73 l / s) averaged 43 l / if current 1.7 l / s realized that the decrease in attendance constituent units of the system decreases somewhere around 97.5% the volume to which the components are designed for and found in the Sewage Treatment Station Sidereal. In the characterization of the metals present in the raw sewage treated and it was found that the Principal Component Analysis of the boron (B) (63.5%) and followed by barium (Ba) with (21.9%) justify 84.48% the coefficient of variation that determine how prevalent metal in the influent. In Effluent Boron (B) showed a coefficient of variation of 73.7% which justifies as the main component in the influent of WWTP. In the characterization of metals in the sludge was observed that with a percentage of 98.8% the Barium (Ba) is the main element found. The results obtained with principal component analysis to characterize the physic-chemical and bacteriological analyzes of raw sewage and treated ETE observed that the variable "total COD" is positively related to component BOD and negatively correlated with the Total Alkalinity . Regarding physic-chemical and bacteriological, high levels of BOD, Fecal coliform, TSS and VSS, from the releases of effluents, making present the highest concentrations of organic load remaining.
83

Uso de geotêxtil para a desidratação de lodo da ETE Vila da Barca-PA

SOUZA, Luciana Otoni de 15 April 2016 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T12:56:50Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_UsoGeotextilDesidratacao.pdf: 2728865 bytes, checksum: 56533bc371e63bb74d7885384eab3e57 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-20T15:08:39Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_UsoGeotextilDesidratacao.pdf: 2728865 bytes, checksum: 56533bc371e63bb74d7885384eab3e57 (MD5) / Made available in DSpace on 2017-03-20T15:08:39Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_UsoGeotextilDesidratacao.pdf: 2728865 bytes, checksum: 56533bc371e63bb74d7885384eab3e57 (MD5) Previous issue date: 2016-04-15 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / FADESP - Fundação de Amparo e Desenvolvimento da Pesquisa / FINEP - Financiadora de Estudos e Projetos / Verifica o desempenho de desidratação do lodo da ETE Vila da Barca com uso de geotêxtil. O condicionamento do lodo foi feito com o auxílio dos produtos químicos coagulante PAC (PolyAluminium Chloride - Policloreto de alumínio- 10%) e floculante polímero catiônico do tipo FLONEX 4400 SH- 0,1%, que permitiram a formação de flocos bem definidos e maiores em curto intervalo de tempo de agitação em Jar test aproximadamente 9”. Para a avaliação e escolha da situação ideal para dosagens no condicionamento foram realizados 25 ensaios com variação das concentrações do lodo bruto e polímero e PAC. Dentre os ensaios, o que se destacou foi o ensaio 3, na segunda dosagem com 95 mg/L de polímero e 8 mg/L de PAC e concentração do lodo de 24.106 mg/L. Para estas dosagens o desaguamento apresentou um filtrado com qualidade satisfatória quanto às características físico-químicas e uma torta com altas concentrações de ST e baixo teor de umidade. No balanço de massa na torta, conseguiu-se obter eficiência do desaguamento do geotêxtil nas 3 primeiras dosagens do ensaio 3 com resultados de 90%, 91% e 91% demonstrando bom desempenho do geotêxtil. Na análise estatística, a formação de duas componentes principais formando o conjunto de todas as variáveis físico-química analisadas dos 3 filtrados resultantes do ensaio 3, demonstraram a homogeneidade, inter-relação e similaridade entre elas, pois conseguem definir com um elevado grau de significância as características do filtrado. / Checks the sludge dewatering performance of ETE Barca Village with use of geotextile. Sludge conditioning was done with the aid of chemical coagulant PAC (polyaluminium chloride - Polyvinyl aluminum- 10%) and the cationic flocculant polymer of the type FLONEX 4400 SH 0.1%, which allowed the formation of well-defined and larger flakes short stirring time interval approximately 9 jar test ". For the evaluation and selection of the ideal situation for dosages on conditioning were performed 25 trials with varying the concentrations of the raw sludge and polymer and PAC. Among the tests, which was stood the test 3, the second dosing with 95 mg / L and 8 mg polymer / L of PAC and concentration of sludge 24,106 mg / L. For these dosages showed a dewatering filtrate with satisfactory quality and the physical and chemical characteristics and a pie with high concentrations of ST and low moisture content. In the mass balance in the cake, it was possible to obtain the geotextile dewatering efficiency in the first 3 doses of the test results 3 with 90%, 91% and 91% showing good performance of geotextile. In the statistical analysis, the formation of two main components forming the set of all physical and chemical variables of 3 filtrates from the 3 trial demonstrated homogeneity, inter-relationship and similarity between them, because they can define with a high degree of significance the filtrate characteristics.
84

ADENSAMENTO DE LODO DE ESTAÇÃO DE TRATAMENTO DE ÁGUA: COMPARAÇÃO ENTRE SEDIMENTAÇÃO E FLOTAÇÃO / SLUDGE THICKENING IN WATER TREATMENT PLANT: COMPARISON BETWEEN SEDIMENTATION AND FLOTATION

Hedlund, Keila Fernanda Soares 04 March 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In water treatment plants (WTP) the solid waste generation is considered very high. The sludge from WTP have their own characteristics, which depend mainly on the captured water quality, the chemicals used in the treatment and cleaning method of the settling basins. The sludge characterization is carried out in laboratory tests before using any type of product or method of treatment. The thickening is one of the most important stages of sludge treatment and it aims to decrease the volume and increase the solids concentration. In this work it was evaluated the performance of the sludge thickening of the WTP São Gabriel RS (Brazil) by sedimentation and flotation with dissolved air (DAF). Sludge samples were collected in two sampling campaigns, which it was characterized and used in the thickening studies. Five different types of polymers (among cationic, anionic and nonionic) were employed, and those which resulted in lower residual turbidity of the clarified water after flocculation, were used in thickening studies. The parameters evaluated after thickening were: remaining turbidity of the clarified water; solids concentration; settling rate (velocity); and resistance to filtration. In the quantitative characterization sludge it was evident in the sludge mass production by means of an empirical equation of 11.8 tons / month and 11.1 tons / month by in loco measurement. Qualitatively the sludge had low biodegradability, and it was classified as waste Class II A - Not Inert , according to the Brazilian Regulation NBR 10.004 (2004). In the thickening studies with different dosages of cationic and anionic polymers (very low density charge - MB) for the settling tests, and only the cationic polymer-MB showed good results for the DAF. In order to compare settling and flotation thickening processes it was found that the remaining turbidity of the clarified water had lower values by treating by DAF. The higher solids concentrations were found in the sludge thickened by sedimentation, to the dosages of 1.0 and 1.5 mg cationic pol. - MB/g SST (7.05 and 7.10%) and 0.25 mg anion pol./g SST (7.04%). Settling rates of the thickened sludge by DAF 50% was higher than the other treatments, but showed no statistic difference to the different polymer dosages. In particular sludge strength tests gave the lowest value for the treatment by sedimentation for dosage of 4.5 mg pol. cationic - MB / g SST (9.0 x 1012 m.kg-1). In conclusion, the use of polymers aided the sludge thickening both in sedimentation as in the DAF thickening processes. However it is necessary prior to the decision making in choosing the kind of the thickening process, to evaluate the polymer type and dosage, determine what will be the subsequent processes of sludge treatment, and which parameters are most relevant according to the WTP. Yet it must be considered the cost and available staff before opting for the use of sludge thickening by sedimentation or DAF. / Em estações de tratamento de água (ETAs) ocorre uma geração elevada de resíduos sólidos. Os lodos de ETAs apresentam características próprias, que dependem principalmente da qualidade da água captada, dos produtos químicos utilizados no tratamento e método de limpeza dos decantadores. A caracterização do lodo é feita com ensaios em laboratório antes de empregar qualquer tipo de produto ou método de tratamento nos resíduos. O adensamento constitui umas das fases mais importantes do tratamento do lodo, pois visa a diminuição do volume e máxima concentração de sólidos. Neste trabalho foi avaliado o desempenho do adensamento do lodo de decantadores da ETA de São Gabriel RS (Brasil), por meio de sedimentação e flotação a ar dissolvido (FAD). Amostras de lodo foram coletadas em duas campanhas de amostragem, sendo este, após caracterizado, utilizado nos ensaios de adensamento. Avaliou-se a utilização de cinco tipos de polímeros (catiônico, aniônico e não-iônico), e aqueles que resultaram em menor turbidez remanescente da água clarificada, após a floculação, foram utilizados nos ensaios de adensamento. Os parâmetros avaliados após o adensamento foram: turbidez remanescente da água clarificada; concentração de sólidos; velocidade de clarificação; e resistência a filtração. Na caracterização quantitativa do lodo foi evidenciada a produção de massa de lodo, por meio de equação empírica, de 11,8 toneladas/mês e de 11,1 toneladas/mês por meio de medição in loco. Qualitativamente o lodo apresentou baixa biodegradabilidade, e quanto à classificação segundo a NBR 10.004 de 2004, o lodo foi classificado como resíduo Classe II A Não Inerte. Nos ensaios de adensamento com diferentes dosagens dos polímeros aniônico e catiônico (muito baixa densidade da carga MB) nos ensaios de sedimentação, e para a FAD apenas o polímero catiônico MB. Na comparação dos tratamentos verificou-se que a turbidez remanescente da água clarificada obteve menores valores por meio do tratamento por FAD. As maiores concentrações de sólidos foram encontradas no lodo adensado por sedimentação, para as dosagens de 1,0 e 1,5 mg pol. catiônico - MB/g SST (7,05 e 7,10%) e 0,25 mg pol. aniônico/g SST (7,04%). A velocidade de clarificação do lodo adensado por FAD 50% foi superior aos demais tratamentos, mas não apresentou diferença estática para as distintas dosagens. Nos ensaios de resistência específica do lodo obteve-se menor valor para o tratamento por sedimentação para a dosagem de 4,5 mg pol. catiônico - MB/g SST(9,0E+12 m.kg-1). Conclui-se que a utilização dos polímeros auxiliou no adensamento do lodo, tanto na sedimentação quanto na FAD. Contudo faz-se necessário antes da tomada de decisão na escolha do processo de adensamento, do tipo de polímero e dosagem utilizada, determinar quais serão os processos subsequentes de tratamento do lodo, e quais os parâmetros são mais relevantes dentro da realidade da ETA. Ainda deve-se considerar os custos e a disponibilidade de pessoal qualificado antes de optar pelo emprego do adensamento do lodo por sedimentação ou por FAD.
85

Resíduos de agroindústrias familiares: Impactos na qualidade da água e tratamento com técnicas simplificadas / Waste of agro-industry family: Impact on water quality and treatment with techniques simplified

Copetti, André Carlos Cruz 26 February 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Human activities have altered the environmental quality especially with regard to water sources. The agro-industry activity in small scale may represent a potential pollutant different from those of other agricultural activities, and, therefore, there is the need to search alternatives to minimize its impacts. This work aims to: (a) assess the quality and quantity of waste solid and liquid Small Scale Agroindustry Family (b) characterize the Small Scale Agro-industry Family in the types of waste and pollution potential, (c) assess the impacts of Small Scale Agro-industry Family in the quality of surface water, and (d) evaluate the efficiency of a simplified treatment of liquid waste. The study was conducted in agricultural members of the group "Rede da Casa; Network Home" of the Fourth Region of the Colony of Italian immigration of Rio Grande do Sul. The thesis was divided into three studies: the first study addressed the characterization of family agro-industry of small scale, the second assessed the impact of agricultural practices on water quality of four streams, and the third addressed the treatment of poultry slaughter waste, production of cheeses, and wines and juices. The waterways are contaminated along the way within the property by different sources of contamination. The Small Scale Agro-industry Family is just one activity that can contribute to poor environmental quality. There is production of organic residues in Small Scale Agro-industry Family, both in liquid and solid form. These have low negative impacts released directly into the environment. The root zones of plants are efficient in the removal of organic and biological contaminants, but constant maintenance must be made. For some types of waste, it is essential to have flotation and deposition tanks and physical filtration tank. / As atividades antrópicas têm alterado a qualidade ambiental principalmente no que se refere aos mananciais de água. As atividades agroindustriais em escala de pequeno porte podem representar potencial poluidor diferentes daquelas das demais atividades agrícolas, e, portanto, há necessidade de propor alternativas para minimizar seus impactos. Este trabalho tem como objetivos: (a) avaliar qualitativa e quantitativamente os resíduos sólidos e líquidos de agroindústrias familiares de pequeno porte; (b) caracterizar as agroindústrias quanto aos tipos de resíduos e o potencial poluidor; (c) avaliar os impactos das agroindústrias na qualidade das águas superficiais; e (d) avaliar a eficiência de sistema simplificado de tratamento de resíduo líquido. O trabalho foi realizado nas agroindústrias integrantes do grupo Rede da Casa da Região da Quarta Colônia de Imigração Italiana do Rio Grande do Sul. A dissertação de mestrado foi organizada em três estudos: o primeiro estudo abordou a caracterização das agroindústrias familiares; o segundo avaliou o impacto das atividades agroindustriais na qualidade de água de quatro córregos; e o terceiro abordou o tratamento de resíduos de abatedouro de aves, de produção de queijos e de vinhos e sucos. Os cursos de água são contaminados ao longo do percurso dentro da propriedade por diferentes fontes de contaminação. A agroindústria é apenas mais uma atividade que pode contribuir para a má qualidade ambiental. Há produção de resíduos orgânicos nas agroindústrias familiares de pequeno porte, tanto na forma líquida ou sólida, e esses apresentam baixos impactos negativos se lançados diretamente no ambiente. As estações de tratamento por zona de raízes são eficientes na remoção da carga orgânica e de contaminantes biológicos, mas devem ser feitas manutenções constantes e, para alguns tipos de resíduos, é fundamental a presença de tanques de deposição e flutuação e tanques de filtração física.
86

Pesquisa de vírus entéricos humanos em lodos de esgoto originários de duas ETEs do Estado de São Paulo: estabelecimento e avaliação de metodologia para recuperação e detecção viral. / Detection of human enteric viruses in sewage sludge from two sewage treatment plants in São Paulo state: establishment and evaluation of a method for viral recovery and detection.

Karina Medici Barrella 10 June 2008 (has links)
O objetivo foi desenvolver e avaliar uma metodologia simplificada para detecção de vírus entéricos humanos em lodo de esgoto. O método foi baseado em eluição viral com solução protéica, seguida de ultracentrifugação. Alguns parâmetros foram avaliados (tempo e pH de eluição, condições de clarificação e purificação). A seguir, foi aplicado à pesquisa de adenovírus, vírus da hepatite A e norovírus em amostras colhidas ao longo de 12 meses em duas ETEs do estado de São Paulo. Amostras pareadas de esgoto foram também examinadas como referência da presença viral. A detecção viral por PCR, RT-PCR e PCR em tempo real, revelou a presença de adenovírus, incluindo os entéricos (espécie F) e vírus da hepatite A tanto nas esgoto como no lodo de ambas as ETEs. Norovírus não foram detectados. Vírus infecciosos não foram detectados no lodo submetido ao tratamento químico (ETE A). Parte dos vírus presentes na água de esgoto ficaram retidos no lodo e análises estatísticas revelaram que o tratamento químico adotado na ETE A é eficiente para a inativação viral. / The aim was to develop and evaluate a simplified methodology for detection of human enteric viruses in sewage sludge. The method was based on viral elution with protein solution, followed by ultracentrifugation. Several parameters were evaluated, including time and elution pH, clarifying and purifying conditions. The method was applied to the detection of adenoviruses, hepatitis A virus and noroviruses in sewage sludge samples collected for twelve months at two sewage treatment plants in Sao Paulo state. Raw sewage samples were also collected as a reference for viral presence. PCR, RT-PCR and Real-Time PCR revealed the presence of adenoviruses, including the enteric ones (species F) and hepatitis A virus found both in sewage and sludge. Noroviruses were not detected in any samples. Cell culture infectious viruses were not detected in the sludge subjected to chemical treatment (STP A), and statistical analyses revealed the efficiency of this treatment for virus inactivation.
87

Contaminantes emergentes em estações de tratamento de esgoto aeróbia e anaeróbia

Grosseli, Guilherme Martins 21 November 2016 (has links)
Submitted by Alison Vanceto (alison-vanceto@hotmail.com) on 2017-01-05T11:02:03Z No. of bitstreams: 1 TeseGMG.pdf: 4914831 bytes, checksum: 1d048739debba70d1c2f92d0a969f785 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2017-01-16T13:42:48Z (GMT) No. of bitstreams: 1 TeseGMG.pdf: 4914831 bytes, checksum: 1d048739debba70d1c2f92d0a969f785 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2017-01-16T13:43:07Z (GMT) No. of bitstreams: 1 TeseGMG.pdf: 4914831 bytes, checksum: 1d048739debba70d1c2f92d0a969f785 (MD5) / Made available in DSpace on 2017-01-16T13:43:18Z (GMT). No. of bitstreams: 1 TeseGMG.pdf: 4914831 bytes, checksum: 1d048739debba70d1c2f92d0a969f785 (MD5) Previous issue date: 2016-11-21 / Outra / The wastewater treatment plant (WWTPs) play an important role to ensuring the health and preservation of aquatic ecosystems through biological removal (mainly) of pollutants and microorganisms in the sanitary and industrial sewage, avoiding the disposal "in natura" of sewage on water and soil. Among these organic contaminants stand out Emerging Contaminants (EC), like pharmaceuticals, personal care products and endocrine disruptors, drug abuse, etc.In this study, it was investigated the occurrence and evaluated the removal of 12 EC: naproxen (NPX), diclofenac (DCF), ibuprofen (IBU), caffeine (CAF), carbamazepine (CBZ), propranolol (PRP), atenolol (ATL ), 1-hydroxyibuprofen (IBU-1OH), 2-hydroxy-ibuprofen (IBU-2OH), 10,11-dihydro-10,11-dihydroxy-carbamazepine (CBZ-DIOH), 2-hydroxy-carbamazepine (CBZ-2OH) at two wastewater treatment plants operating with biologic system, one aerobic and another one anaerobic. The first one is located in Jundiaí / SP city and the second one in São Carlos / SP. The target compounds were extracted from the aqueous phase by solid phase extraction (SPE). The analytical determinations were done through liquid chromatography coupled to mass spectrometry with triple quadrupole analyzer (UPLC-MS / MS).Pharmaceuticals, metabolites and personal care product triclosan were detected in all samples. The WWTP CSJJundiaí, which operates in aerobic system showed high removal values (R>70%), in all samples, for the CAF, NPX, ATL, IBU-1OH and TCS, moderate removal (70%>R> 20%) for the IBU and IBU-2 OH, low removal (R <20%) and production (R <0%) for CBZ and PRP.On the other hand ETE-Monjolinho, which operates in an anaerobic system presented a less removal of contaminants, where only caffeine had R> 70%.Thecompounds TCS IBU-2OH, IBU-1OH and ATL was moderate removal, CBZ-DIOH, CBZ and IBU was poorly removal, while it was observed production of DCF, PRP and CBZ-2OH (R < 0%). The metabolite CBZ-DIOH was recalcitrant to degradation in both WWTP. Moreover, it was noticed that WWTP can not only promote the degradation of some contaminants but also the production of the same, as is the case of DCF, CBZ, CBZ-2OH, CBZ-DIOH and PRP in both WWTP, and Moreover, it is possible to observe that STPs can promote not only the degradation of some contaminants but also the production of the same, as is the case of DCF, CBZ, CBZ-2 OH, CBZ-DIOH and PRP in both STPs, and ATL, IBU, and IBU-1OH only in ETE-Monjolinho. Despite both WWTP not completely remove the organic contaminants, it was found that WWTP with aerobic biodegradation has proved more effective in removing the EC than anaerobic biodegradation.The currently WWTP technologies are not able to eliminated most of EC, providing this contaminants into water bodies. This work aim to contributes to the understanding the EC in WWTP, in order to support better operating parameters of WWTP or the requirement of new technologies which allowed the removal of these contaminants providing treated wastewater that could helping for the global water scarcity problem. / As Estações de Tratamento de Esgoto (ETEs) desempenham papel importante na garantia da saúde pública e preservação dos ecossistemas aquáticos por meio da remoção biológica (majoritariamente) de poluentes e microorganismos presentes no esgoto sanitário e industrial, evitando o aporte“in natura”do esgoto nos corpos hídricos e solos. Dentre estes contaminantes orgânicos destacam-se os Contaminantes Emergentes (CE), uma categoria composta por fármacos, produtos de higiene pessoal e desreguladores endócrinos, drogas de abuso, entre outros. Neste trabalho foi investigada a ocorrência e avaliada a remoção de 12 CE, sendo eles: naproxeno (NPX), diclofenaco (DCF), ibuprofeno (IBU), cafeína (CAF), carbamazepina (CBZ), propranolol (PRP), atenolol (ATL), 1- hidroxi-ibuprofeno (IBU-1OH), 2-hidroxi-ibuprofeno (IBU-2OH), 10,11-dihidro-10,11-dihidroxi-carbamazepina (CBZ-DIOH), 2-hidroxi-carbamazepina (CBZ-2OH) em duas estações de tratamento de esgoto que operam sistemas biológicos, sendo uma aeróbia e outra anaeróbia. A primeira fica na cidade de Jundiaí/SP e a segunda opera na cidade de São Carlos/SP. Os compostos alvos foram extraídos da fase aquosa por extração em fase sólida (SPE). As determinações analíticas foram feitas por cromatografia líquida de ultra eficiência acoplada àespectrometria de massas com analisador triplo quadrupolo (UPLC-MS/MS). Os fármacos, metabólitos e o produto de higiene pessoal triclosan foram detectados em todas as amostras analisadas. A CSJ-Jundiaí, que opera em regime aeróbio, apresentou ao longo das campanhas amostrais, altos valores de remoção (R>70%) para a CAF, NPX, ATL, IBU-1OH e TCS, remoção moderada (70%> R > 20%) para o IBU e IBU-2OH, baixa remoção (R<20%) e formação/produção (R<0%) para a CBZ e PRP. Já a ETEMonjolinho, que opera em regime anaeróbio, apresentou um panorama menos favorável na remoção dos contaminantes alvos obtendo R>70% apenas para a cafeína. Os compostos TCS, IBU-2OH, IBU-1OH e ATL tiveram remoção moderada, ao passo que CBZ-DiOH, CBZ e IBU apresentaram baixa remoção e formação/produção do DCF, PRP e CBZ-2OH. O metabólito CBZ-DiOH mostrou-se recalcitrante a degradação em ambas ETEs. Além do mais, é possível observar que as ETE podem promover não somente a degradação de alguns contaminantes mas também a formação/produção dos mesmos, como é o caso do DCF, CBZ, CBZ-2OH, CBZ-DiOH e PRP em ambas ETEs, havendo ainda na ETE-Monjolinho a formação de ATL, IBU, e IBU-1OH. Apesar de ambas ETEs não removerem completamente os compostos avaliados, observouse que o tratamento de esgoto empregando a biodegradação aeróbia tem se mostrado mais eficaz na remoção dos CEs frente à biodegradação anaeróbia. Os sistemas atualmente empregados na maioria das ETEs, não livram os corpos aquáticos da presença de CE. Este trabalho contribui para o conhecimento do comportamento de alguns CE em modelos de ETE comumente empregadose pode amparar estratégias de ajustes de condições operacionais ou o uso de tecnologias que possibilitem a remoção destes contaminantes, contribuindo para que os efluentes das ETEspossam ser transformados em água de reuso de boa qualidade, atualmente uma das alternativas para o gerenciamento do problema global da escassez hídrica.
88

Avaliação da qualidade da água de lavagem de filtros e de lodo de decantador após tratamento sequencial por leito de drenagem, flotação por ar dissolvido e filtração

Oliveira, Nilton Fernandes de 12 February 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this study, we evaluated the quality of filter backwash water and sludge decanter Water Bom Jardim Treatment Plant, located in Uberlandia, Minas Gerais, after sequential treatment with drainage bed, flotation and filtration dissolved air, all bench scale. Compounds were evaluated drainage bed effluent three different types of geotextile webs: RT-21, RT-26 and RT-31, and tested three kinds of constituents of the sand grain size filters. The effluent drained, after passage through the drainage bed, passed through the flotation unit dissolved air and then by filtration units. Preliminary tests with crude sample of filter backwash water and sludge decanter, in order to characterize it and evaluate it as its physical, chemical and biological were performed. The geotextile webs used were chosen from results of previous studies, performed with the same type of system. The experiments were divided into stages I and II. In step I were conducted without addition of coagulant or auxiliary experiments on coagulation / flocculation flotation. The samples, after passage through the system, evaluating physical parameters pH, turbidity, true color and apparent color and about the chemical parameters, remaining concentrations of aluminum and iron. Step II The same tests were carried out in the same step I and determination of quality parameters, however, with aluminum sulphate dose of 5, 10 and 15 mg / L in the coagulation / flocculation flotation. Tests conducted in step I showed better performance were performed with the RT-26 blanket in the output of filter 01 with a reduction of 91.8% of the apparent color, 41.4% of true color and 97.6% turbidity. In phase II trials conducted in the best performance was drained with the RT-mat 26 the output of the filter 02 when subjected to a dosage of 15 mg / L aluminum sulfate as a coagulant agent. There was a reduction of 96.4% of the apparent color, 86.2% of true color and 99.6% turbidity. The presented results confirm the efficiency of the system in removing solids present in the water washing of filters and ETA decanter sludge studied and confirmed the capability of using this system as an alternative to disposal or optionally for a new water supply line treated. / Neste trabalho foi avaliada a qualidade da água de lavagem de filtros e de lodo de decantador da Estação de Tratamento de Água Bom Jardim, localizada na cidade de Uberlândia-MG, após tratamento sequencial por leito de drenagem, flotação por ar dissolvido e filtração, todos em escala de bancada. Foram avaliados efluentes de leitos de drenagem compostos de três tipos de mantas geotêxteis distintas: RT-21, RT-26 e RT-31, e testados três tipos de granulometria de areia constituintes dos filtros. O efluente drenado, após passagem pelo leito de drenagem, passava pela unidade de flotação por ar dissolvido e em seguida pelas unidades de filtração. Foram realizados testes preliminares com amostra bruta da água de lavagem de filtros e de lodo de decantador, com o objetivo de caracterizá-la e avaliá-la quanto as suas características físicas, químicas e biológicas. As mantas geotêxteis utilizadas foram escolhidas a partir de resultados de trabalhos anteriores, realizados com o mesmo tipo de sistema. Os experimentos foram divididos nas etapas, I e II. Na etapa I foram conduzidos experimentos sem adição de agente coagulante ou auxiliares na coagulação/floculação da flotação. As amostras, após passagem pelo sistema, foram avaliadas quanto aos parâmetros físicos pH, turbidez, cor verdadeira e cor aparente e quanto aos parâmetros químicos, concentrações remanescentes de Alumínio e Ferro. Na etapa II foram realizados os mesmos ensaios da etapa I e mesmas determinações dos parâmetros de qualidade, entretanto, com dosagem de sulfato de alumínio de 5, 10 e 15 mg/L na coagulação/floculação da flotação. Os ensaios conduzidos na etapa I que mostraram melhor desempenho foram os realizados com a manta RT-26 na saída do Filtro 01 com redução de 91,8% da cor aparente, 41,4% da cor verdadeira e 97,6% da turbidez. Nos ensaios conduzidos na etapa II o melhor desempenho foi com o drenado da manta RT-26 na saída do Filtro 02 quando submetido a uma dosagem de 15 mg/L de sulfato de alumínio, como agente coagulante. Houve redução de 96,4% da cor aparente, 86,2% da cor verdadeira e 99,6% da turbidez. Os resultados apresentados confirmam a eficiência do sistema na remoção de sólidos presentes na água de lavagem de filtros e de lodo de decantador da ETA estudada, e confirmam a potencialidade de utilização deste sistema como alternativa ao descarte e como opção de nova linha de fornecimento de água tratada. / Mestre em Engenharia Civil
89

Utilização de lodo de estação de tratamento de água na produção de mudas de árvores com ocorrência no Cerrado / Use of sludge treatment plant water in the production of tree seedlings to occurrence in the savanna

FIGUEIREDO NETO, Abner 02 September 2011 (has links)
Made available in DSpace on 2014-07-29T15:01:47Z (GMT). No. of bitstreams: 1 DissertacaoAbneFigueiredoNeto.pdf: 3315403 bytes, checksum: fa71315e1c2d245dfe9bb258f5291ad0 (MD5) Previous issue date: 2011-09-02 / Disposal of sludge from Water Treatment Plants (WTP) in the environment is very harmful and can cause deterioration of water supplies. Existing methods for treatment of waste produced in ETA are few applied because the costs involved with operation and maintenance. Several alternatives are suggested for the disposal of these wastes, including the application of sludge in agricultural soils can generate several benefits. In this work we evaluated the development of crops with different dosages of WTS (0%, 18.75%, 37.50%, 56.25%, 75%). The sludge used in the study was collected in the ETA Eng. Rodolfo José da Costa, located in Goiânia/GO, which is used in aluminum sulphate (Al2 (SO4) 3) as a primary coagulant. For the study we used five treatments (T1: 25% substrate, 75% land, 0% sludge, T2: 25% substrate, land 56.25%, 18.75% sludge, T3: 25% substrate, 37.50 % land, 37.50% sludge, T4: 25% substrate, land 18.75%, 56.25% sludge, T5: 25% substrate, 0% land, 75% sludget) for four species of native plants occurring in cerrado (Padu-de-óleo; Gonçalo-alves; Canafístula and Ipe-brando). We adopted the completely randomized design (CRD) with four repetitions, totaling 400 plants. The data collections were performed at 30, 60, 90, 120 and 150 days after planting. Parameters such as the collar diameter, height, weight and chlorophyll were evaluated. Some relationships were used to determine the level of quality seedlings, as the ratio of shoot height and diameter of the collar, the relationship between height and dry weight of shoots and the ratio of dry weight of shoots and dry weight of roots. The largest number of dead individuals was found for Ipê-branco (Tabebuia roseo-alba), regardless of the treatment he underwent. The morphological parameters showed little variation among treatments. Compared to quality, some species showed the best 4 and subjected to treatment with 56.25% of sludge. In the treatments with higher amounts of sludge, the levels of nitrogen (N), potassium (K), calcium (Ca) and magnesium (Mg) in leaves were reduced. It was found that the allocation of the WTS nursery can be an alternative available and also an economic advantage to commercial nurseries. It is expected not only to encourage the commercial use of residue in crops that require specific concentrations of metals such as aluminum, abundant in the mud, the greater concern is the environmental and ecological nature, as tons of waste are discarded altogether, causing pollution and occupation of space unnecessarily. / O descarte do lodo das Estações de Tratamento Água (ETA) no meio ambiente é bastante nocivo, podendo provocar a deterioração dos mananciais. Os métodos existentes para tratamento dos resíduos produzidos em ETA são poucos aplicados em virtude dos custos envolvidos com operação e manutenção. Várias alternativas são sugeridas para a disposição destes resíduos, entre elas a aplicação do lodo em solos agrícolas pode gerar diversos benefícios. Neste trabalho foi avaliado o desenvolvimento de plantas cultivadas com diferentes doses de lodo de ETA (0%; 18,75%; 37,50%; 56,25%; 75%). O lodo utilizado no estudo foi coletado na ETA Eng. Rodolfo José da Costa, localizada em Goiânia/GO, na qual é utilizado o sulfato de alumínio (Al2(SO4)3) como coagulante primário. Para o estudo utilizaram-se 5 tratamentos (T1: 25% substrato, 75% terra, 0% lodo; T2: 25% substrato, 56,25% terra, 18,75% lodo; T3: 25% substrato, 37,50% terra, 37,50% lodo; T4: 25% substrato, 18,75% terra, 56,25% lodo; T5: 25% substrato, 0% terra, 75% lodo) para 4 espécies de plantas nativas com ocorrência no cerrado (Pau-de-óleo; Gonçalo-alves; Canafístula e Ipê-branco). Adotou-se o delineamento experimental inteiramente casualizado (DIC), com 4 repetições, num total de 400 plantas. As coletas de dados foram realizadas aos 30, 60, 90, 120 e 150 dias após o plantio. Parâmetros como o diâmetro do coleto, altura, peso e clorofila foram avaliados. Algumas relações foram utilizadas para a determinação do índice de qualidade das mudas, como a relação altura da parte aérea e o diâmetro do coleto, a relação da altura e o peso de matéria seca da parte aérea e a relação entre o peso de matéria seca da parte aérea e o peso de matéria seca das raízes. O maior número de indivíduos mortos foi encontrado para o Ipê-branco (Tabebuia roseo-alba), independente do tratamento a que foi submetido. Os parâmetros morfológicos apresentaram poucas variações significativas entre os tratamentos. Em relação aos índices de qualidade, algumas espécies apresentaram os melhores valores quanto submetidas ao tratamento 4, com 56,25% de lodo. Nos tratamentos com maior quantidade de lodo, os teores de nitrogênio (N), potássio (K), cálcio (Ca) e magnésio (Mg) nas folhas foram reduzidas. Verificou-se que a destinação de lodo de ETA para viveiros pode ser uma alternativa de disposição e ainda uma vantagem econômica para os viveiros comerciais. Espera-se não somente incentivar o uso comercial do resíduo em plantios que requeiram concentrações específicas de metais, tais como o alumínio, abundante no lodo; o maior interesse é de cunho ambiental e ecológico, visto que toneladas desse resíduo são completamente descartadas, gerando poluição e ocupação de espaços desnecessariamente.
90

Efeito de distúrbio causado pelo despejo de efluente orgânico sobre a comunidade de insetos aquáticos / Effect of disturbance caused by dumping of organic waste in the community of aquatic insects

ARAÚJO, Cecília Santiago do Carmo 28 April 2011 (has links)
Made available in DSpace on 2014-07-29T16:21:19Z (GMT). No. of bitstreams: 1 Dissertacao Cecilia Santiago.pdf: 860839 bytes, checksum: f9b8cd8d503e76ba7346ce5cf34b8356 (MD5) Previous issue date: 2011-04-28 / Among several environmental impacts caused by human activities, the release of domestic and industrial effluents has been major disturbances that cause degradation of water quality in natural systems by altering their physical, chemical and biological features. For this reason, the aim of this work was to evaluate the effect of discharging organic waste from five Sewage Treatment Plants (STP) on abundance, richness and composition of aquatic insect fauna present in streams receiving sewage, in addition to test the hypotheses that i) disturbance caused by the discharge of effluents from STP alters the abundance of some groups of aquatic insects in the site downstream when compared to the upstream of site and ii) the taxonomic composition of the downstream impact of STPs is modified by the presence of resistant taxa.Thus, the sampling of aquatic insects and measures of some limnological variable was carried out during the drought of 2010, with the Surber sampler, 100m upstream and 100m downstream from the effluent discharge. Chironomidae and EPT larvaes (Ephemeroptera, Plecoptera and Trichoptera) were identified to genus. To test the hypothesis, a paired t test was performed with logarithmic data of total abundance, a paired t test with the richness of taxa identified at family and genus level. To evaluate the composition of the taxa sampled in two parts in relation to environmental variables were carried out two CCA separately, one with the taxa of Chironomids and one with the EPT. The results showed that abundances recorded downstream (&#956; = 4523.8 ± 2578.9) was higher than that recorded upstream (&#956; = 863.4 ± 508.4) on all STP. The results of paired t test using values of total abundance of taxa showed significant differences between upstream and downstream (paired t test: t = 4.21, d.f. = 4, p = 0.01), indicating the elimination of sensitive taxa and the increase abundance of dominant taxa, favored by the physical and chemical changes of water, such as Chironomus, resistant to high concentrations of organic debris. Both genera richness (paired t test: t = 0.791, d.f. = 4, p = 0.473) as the families (paired t test: t = 1.537, df = 4, p = 0.199) were not different in two sites, showing that this indicator is not the most appropriate in cases in which there is replacement of taxa.The ordinations produced by the CCAs were complementary, confirming the replacement of taxa between upstream and downstream, where larvaes like Farrodes, Tricorythodes, Alisotrichia and Mortoniella were favored by more oxygenated water. Thus, it was evident that the organic sewage discharge by STP modified the community structure of aquatic insects found in streams increasing the abundance, altering the dominance order and causing replacement of taxa between upstream and downstream / Dentre os diversos impactos ambientais causados pelas atividades antrópicas, o despejo de efluentes domésticos e industriais tem sido um dos principais distúrbios que causam a degradação da qualidade da água em sistemas naturais por alterarem suas características físicas, químicas e biológicas. Por esta razão, o objetivo deste trabalho foi verificar o efeito do lançamento de resíduos orgânicos de cinco Estações de Tratamento de Esgoto (ETEs) sobre abundância, riqueza e composição da entomofauna aquática presentes nos córregos receptores, além de testar as hipóteses de que: i) o distúrbio causado pelo despejo de efluentes de ETEs altera a abundância de alguns grupos de insetos aquáticos no trecho de jusante quando comparado ao trecho de montante e ii) a composição taxonômica a jusante do impacto das ETEs é modificada devido à presença de táxons resistentes. Desta forma, a coleta de insetos aquáticos e medidas de algumas variáveis limnológicas foram realizadas no período de estiagem de 2010, com o auxílio do amostrador Surber, 100m a montante e 100m a jusante do despejo do efluente. As larvas de Chironomidae e de EPT (Ephemeroptera, Plecoptera e Trichoptera) foram identificadas até gênero. Para testar as hipóteses foi realizado um teste t pareado com os dados de abundância total logaritmizados, um teste t pareado com a riqueza de táxons identificados em nível de família e em nível de gênero. Para avaliar a composição dos táxons nos dois trechos amostrados em relação às variáveis ambientais foram feitas duas CCA separadamente, uma com os táxons de Chironomidae e uma com os de EPT. Os resultados mostraram que abundância registrada a jusante (µ= 4.523,8 ± 2.578,9) foi maior que a registrada a montante (µ= 863,4 ± 508,4) em todas as ETEs. O resultado do teste t pareado utilizando valores de abundância total dos táxons mostrou diferenças significativas entre montante e jusante (Teste t pareado: t= 4,21; g.l.= 4; p= 0,01), indicando a eliminação de táxons sensíveis e o aumento na abundância de táxons dominantes, favorecidos pelas mudanças físicas e químicas da água, como é o caso de Chironomus, resistente a altas concentrações de detritos orgânicos. Tanto a riqueza de gêneros (Teste t pareado: t= 0,791; g.l.= 4; p= 0,473) quanto a de famílias (Teste t pareado: t= 1,537; g.l.= 4; p= 0,199) não foram diferentes nos dois trechos, mostrando que este indicador não é o mais adequado em casos em que ocorre substituição de táxons. As ordenações produzidas pelas CCAs foram complementares, confirmando a substituição de táxons entre montante e jusante, em que larvas como Farrodes, Tricorythodes, Alisotrichia e Mortoniella foram favorecidas pelas águas mais oxigenadas. Desta forma, foi evidente que o lançamento de resíduos orgânicos pelas ETEs modificou a estrutura da comunidade de insetos aquáticos presentes nos córregos receptores aumentando a abundância, alterando a ordem de dominância e causando substituição de táxons entre montante e jusante.

Page generated in 0.1304 seconds