11

Análise da influência de um reforço de solo-cimento compactado na extremidade superior de estacas escavadas, sob carregamentos horizontais /

Fioratti, Netúlio Alarcón. January 2008 (has links)
Orientador: Antonio Anderson da Silva Segantini / Banca: Adriano Souza / Banca: Miriam Gonçalves Miguel / Resumo: Nesta pesquisa foi executado um reforço (cilíndrico com 1 m de diâmetro e 1 m de profundidade) de solo-cimento (cujo solo foi corrigido granulometricamente com resíduo de concreto triturado) compactado ao redor do fuste de estacas de concreto escavadas com trado mecânico (com 32 cm de diâmetro e profundidade de 8,71 m) em solo arenoso do Campo Experimental da UNESP em Ilha Solteira-SP com o intuito de avaliar sua contribuição para neutralização das cargas horizontais. A mistura entre solo e resíduo na proporção de 1:1 em massa, estabilizada com 8% de cimento (em massa seca de mistura) foi testada e mostrou-se bastante adequada para a utilização neste propósito, pois, para ser estabilizada com cimento, a mistura necessitou de menor quantidade de cimento que o solo natural (2 pontos percentuais) e o solo-cimento daí resultante apresentou resistência aos 28 dias de 6,32 MPa. Após ensaio de carregamento horizontal nas estacas reforçadas e comparação com os resultados de ensaios nas mesmas estacas sem reforço obtidos de Del Pino Jr. (2003), observou-se que para uma mesma carga aplicada os deslocamentos sofreram grande redução, enquanto para atingir um mesmo deslocamento foi necessário elevado acréscimo de carga. O coeficiente de reação horizontal do solo (nh) do conjunto estaca-solo em questão teve uma elevação da ordem de 200% do valor original. Também foram calculados os esforços (cortantes e fletores) e deslocamentos ao longo do fuste das estacas, que apresentaram sensível redução, para mesma carga aplicada, após reforço. Os resultados apontam o resíduo de concreto triturado como excelente material para correção granulométrica de solos utilizados para confecção de solocimento compactado e o solo-cimento compactado como um cilindro no entorno de estacas escavadas em solo arenoso sendo um reforço bastante eficiente para absorver esforços horizontais / Abstract: This research produced one improvement (cylindrical - 1 meter diameter and 1 meter deep) made of soil-cement (wich soil was granulometrically corrected with concrete ground remains) compacted around the concrete bored piles head (32 cm diameter and 8,71 meters deep) on a sandy soil from the Trial Field of UNESP, Ilha Solteira - SP, in order to measure it's contribution to neutralize the horizontal loading. The mix between soil and remains in proportions 1:1 in mass, stabilized with 8% of cement (dry mass of mix) was tested and proved to be very adequate for the research purpose, because the mix needed less quantity of cement than natural soil (2 percentage points) to be stabilized and the soil-cement resulting presented resistance in 28 days of 6,32 MPa. After the test of horizontal loading on the reinforced piles, compared with the results of tests with the same piles without improvement obtained from Del Pino Jr (2003), it was observed that for the same applied load the displacements had a great reduction, while for reaching the same displacement need high load increasing. The coefficient of the soil's horizontal reaction (nh) from the set pile-soil concerned has it's value increased to 200% from the original value. Also were measured the efforts and displacements along the stem piles, that had significant reduction after improvement. Results indicate ground concrete remains as an excellent material for granulometric correction of soil for confection of compacted soil-cement and the compacted soil-cement as a cylinder around the excavated piles head on sandy soil proved to be very efficient to absorb horizontal efforts / Mestre
12

Comportamento de estacas escavadas de pequeno diâmetro em solo laterítico e colapsível da região de Campinas/SP / Behavior of bored piles of small diameter in collapsible and lateritic soil in the region of Campinas/SP

Scallet, Marcella Maschietto 17 August 2018 (has links)
Orientador: Miriam Gonçalves Miguel / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-17T14:10:40Z (GMT). No. of bitstreams: 1 Scallet_MarcellaMaschietto_M.pdf: 1855400 bytes, checksum: 6ec58c53afe478625fb1fa36239f671c (MD5) Previous issue date: 2011 / Resumo: Este trabalho tem como objetivo estudar o comportamento de estacas escavadas de pequeno diâmetro, submetidas a carregamentos axiais de compressão através de provas de carga estática realizadas no Campo Experimental de Mecânica dos Solos e Fundações 2 da Unicamp. O CEMSF2 apresenta um perfil geológico cuja primeira camada é constituída de argila siltosa, coluvionar, laterítica e colapsível. Pretendeu-se avaliar as capacidades de carga e os recalques dessas estacas nas condições: a) sem pré-inundação e sem melhoria de ponta; b) sem pré-inundação e com melhoria de 1 ponta, com o lançamento de um volume de 18 litros de brita 1 no fundo da estaca antes da concretagem; c) com pré-inundação e sem melhoria de ponta e d) com préinundação e com melhoria de ponta. Todas as estacas foram submetidas a dois carregamentos (ensaios e reensaios), sob uma mesma condição acima descrita. Foram instalados tensiômetros convencionais para a leitura das sucções matriciais do solo durante a realização das provas de carga. Através das curvas carga versus recalque foram definidas as capacidades de carga e as resistências ao atrito lateral e de ponta, por meio de métodos de interpretação dessas curvas com o solo sem inundação e préinundado por 48horas, considerando as reduções dos valores da sucção matricial do solo, devido às duas condições de umidade. A capacidade de carga das estacas nos ensaios foi menor do que nos reensaios, para as estacas sem pré-inundação, devido ao aumento da resistência de ponta nos reensaios. Nas provas de carga com préinundação, em geral, não houve aumento de resistência de ponta dos ensaios para os reensa ios. A resistência ao atrito lateral foi maior que a resistência de ponta em todas as provas de carga. O lançamento de brita 1 não trouxe melhorias na capacidade de carga. Reduções consideráveis na capacidade de carga foram observadas em função da pré-inundação do solo, sendo essas reduções mais expressivas para as estacas com melhoria de ponta / Abstract: This paper aims to study the behavior of bored piles of small diameters, subjected to axial compression loads by static load tests carried out at the Field of Experimental Soil Mechanics and Foundation 2 at Unicamp. The CEMSF2 has a geological profile whose first layer is composed of silty clay, with coluvionar, lateritic, and collapsible features.This study intended to evaluate the load capacities and the settlements of these foundations in such conditions: a) without any pre- wetting nor improvement in the tip; b) without any pre-wetting but with a tip improvement, placing a volume of 18 liters of stones 1 in the base of the pile before concreting c) with pre- wetting but without tip improvement and d) with pre-wetting and tip improvement. All these piles were subjected to two loading (tests and retests), under the same test condition described above. Conventional tensiometers were installed to read the matric suctions of the soil during the performance of the load tests. Throughout the load versus settlement curves the load capacities and the strength to lateral friction and tip were defined using methods of interpretation of these curves with the soil without any pre-wetting and 48-hour-pre wetting, considering the reductions of the values of the soil matric suction due to two moisture conditions. The load capacity of piles in the tests was smaller than the one in the retests for the piles without any pre-flooding, due to the increase of the tip strength in the retests. In the load tests with pre-flooding, in general, there was not any increase of strength in the tip of the tests for the retests. The strength to the lateral friction was greater than the tip strength in all loading tests. The placing stones 1did not result any improvement to the bearing capacity. Considerable reductions in bearing capacity were observed because of the pre-wetting soil, such reductions are more significant for the piles with improved tip / Mestrado / Geotecnia / Mestre em Engenharia Civil
13

Estacas submetidas a esforços horizontais em solos colapsiveis do interior de São Paulo, nas condições natural, melhorada e inundada / Horizontally loaded piles in collapsible soils of the interior of the state of São Paulo, under the conditions of natural humidity, improved soil and pre-flooded soil

Miranda Junior, Gentil 12 November 2006 (has links)
Orientador: David de Carvalho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-09T05:45:20Z (GMT). No. of bitstreams: 1 MirandaJunior_Gentil_D.pdf: 36304791 bytes, checksum: 88909d0a8735e0e6ebf6251c718ba4cb (MD5) Previous issue date: 2006 / Resumo: O problema de estacas carregadas horizontalmente no topo é freqüente em obras de construção civil e há uma reduzida bibliografia sobre os parâmetros a serem adotados em projetos. Uma situação mais crítica é a de estacas carregadas horizontalmente em solos de alta porosidade, não saturados e colapsíveis. Os objetivos deste trabalho são: (1) proporcionar subsídios para o projeto de fundações com carregamento horizontal, chamando a atenção para o danoso efeito de uma inundação de um solo colapsível; (2) fornecer valores do coeficiente de reação horizontal ('n IND. h') para uma argila silto arenosa de alta porosidade, solo de diabásio, comum na região de Campinas, para condições de umidade natural, solo pré-inundado, solo melhorado com solocimento e solo-cimento pré-inundado; (3) compararos valores obtidos com valores de 'n IND. h' para solos freqüentemente encontrados no interior do Estado de São Paulo e em outras regiões do Brasil; (4) propor uma melhoria das condições do sistema solo-estaca através da troca do solo ao redor do topo da estaca por solo-cimento compactado. Para a análise deste problema, foram realizadas vinte e uma provas de cargas horizontais no Campo Experimental de Fundações da Unicamp, em catorze estacas de quatro tipos, nas quatro condições de solo citadas acima. E foram analisadas outras provas de carga realizadas em Campos Experimentais do Estado de São Paulo, todos localizados em regiões com solos superficiais com características desfavoráveis ao carregamento horizontal. Comparam-se valores do coeficiente de reação horizontal do solo ('n IND. h') para diferentes condições do solo, destacando-se a importância de se obter parâmetros do solo regionalmente. Os principais resultados encontrados foram, além dos valores de coeficiente de reação horizontal para o solo de basalto do local e a compilação de valores para solos de alta porosidade de outras regiões - encontrando-se valores diferentes dos propostos na bibliografia -, a acentuada redução do 'n IND. h' (valoresem tomo de 40 vezes menores) ocasionada pela préinundação do solo, o acentuado aumento do 'n IND. h'(valores em média 5 vezes maiores) com a melhora do solo através do solo-cimento compactado,e a redução do 'n IND. h' com a pré-inundação do solo-cimento (valores em média 7 vezes menores). Nota-se que a redução devido à préinundação do solo-cimento é bem inferior a da pré-inundaçãodo solo na umidade natural. Conclui-se que, num projeto onde há a atuação de esforços horizontais e presença de solo colapsível, é necessário contar com a possibilidade de uma inundação do solo, tomar medidas preventivas contra a mesma e utilizar parâmetros do solo adequados. Ou adotar soluções de melhoria do solo, como a utilização do solo-cimento compactado ao redor da cabeça da estaca, que também podem ser adotadas em casos de baixa resistência do solo superficial (seja o solo colapsível ou não) / Abstract: The problem with piles loaded horizontally at the top is frequently met in civil construction projects and there is a reduced bibliography on the parameters to be adopted in designoA more critical situation is that of horizontally loaded piles in high porosity, non saturated and collapsible soils. The objectives of this paper are: (1) produce subsidies for the design of foundations with horizontalloads, calling attention to the damaging effect of flooding on a collapsible soil; (2) supply values for the horizontal reaction coefficient ('n IND. h') for the soil of the Experimental Field at Unicamp, for the conditions of natural humidity, pre-flooded soil, soil improved with soil-cement and pre-flooded soil-cement; (3) compare values of nh for the soils frequently found in the interior of the State of São Paulo and in other regions in Brazil; (4) propose an improvement in the conditions of the soil-pile system soils by changing the soil around the top of the pile for compacted soil-cement. To analyze this problem, twenty one horizontal loading tests were made in the Experimental Foundation Field at Feagri-Unicamp, on fourteen piles of four types, under the four soil conditions mentioned above. Other loading tests made in Experimental Fields in the State of São Paulo were analyzed, alI of them located in regions with surface soils with unfavorable characteristics for horizontal loading. The coefficients of horizontal soil reaction ('n IND. h') for different soil conditions are compared, emphasizing the importance of obtaining regional soil parameters. The principal results found were, besides the values for the coefficient of horizontal reaction for the basalt soil at the location and the compilation of values for high porosity soils of other regions - encountering different values from °those proposed in literature - an accentuated reduction of nh (values around 40 times less) caused by the pre-flooding of the soil, the accentuated increase in 'n IND. h' values (as a mean, 5 times greater) with the soil improvement by compacted soil-cement and the reduction in 'n IND. h' with pre-flooding of the soilcement (mean values 7 times smaller). It is seen that the reduction due to pre-flooding of the soil-cement is much less than that for pre-flooding the soil at natural humidity. One concludes that in a project where horizontal forces act and in collapsible soil, one must count with the possibility of soil flooding, taking preventive measures against this and using adequate soil parameters or, adopt solutions for soil improvement, as by using compacted soil-cement around the pile head, a procedure which can also be adopted in cases of low surface soil resistance (collapsible soil or not) / Doutorado / Construções Rurais e Ambiencia / Doutor em Engenharia Agrícola
14

Influência do consumo de cimento e da relação água/cimento em argamassas para execução de estaca raiz / Influence of consumption of cement and of the water/cement ratio in mortars to produce root piles

Laister, Eliézer 21 August 2018 (has links)
Orientador: Paulo José Rocha de Albuquerque / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-21T07:16:20Z (GMT). No. of bitstreams: 1 Laister_Eliezer_M.pdf: 9273595 bytes, checksum: 143d883d817e6a2b13b7baf7e0af8df9 (MD5) Previous issue date: 2012 / Resumo: Para a confecção de argamassa para o preenchimento da estaca raiz, a norma vigente, NBR 6122/2010 recomenda uma resistência mínima de 20 MPa, consumo mínimo de cimento de 600 kg/m³, e relação A/C entre 0,5 a 0,6, porém a determinação de consumo mínimo de cimento é um tema polêmico quanto à garantia de durabilidade, no entanto, nessas condições, com um consumo de cimento nesse patamar, ter-se-á resistência à compressão axial acima dos 20 MPa exigidos por norma sem grande tecnologia para a confecção de argamassas. A presente pesquisa estudou a influência do consumo de cimento e da relação A/C por meio de ensaios de absorção capilar, avaliando seu desempenho para condições de consumo de cimento menor do que 600 kg/m³. Identificou-se que além do consumo de cimento e relação A/C, a distribuição granulométrica tem influência na absorção capilar, e que é possível obter argamassas com baixa absorção e consumos menores que 600 kg/m³, através do controle da distribuição granulométrica global e utilização de aditivos para o controle da relação A/C. A presente pesquisa também recomenda a utilização do mini slump em campo para o controle da exsudação das argamassas / Abstract: The standard in force (NBR 6122/2010) for preparation of mortar to fill root piles recommends minimum resistance of 20MPa, minimum consumption of cement of 600 kg/m³, and W/C ratio between 0.5 and 0.6. However, determining the minimum consumption of cement to ensure durability is a controversial topic. Under these conditions, with a consumption of cement at this level, we will get resistance to axial compression above 20MPa as required by a standard without top technology to produce mortars. The present research reviewed the influence of consumption of cement and the W/C ratio by means of capillary absorption tests, and assessed their performance under conditions of consumption of amounts of cement smaller than 600 kg/m³. It was observed that, besides consumption of cement and the W/C ratio, the granulometric distribution also impacts capillary absorption and it is possible to get mortars with low absorption and consumptions below 600 kg/m³ through control of the global granulometric distribution and use of additives to control the W/C ratio. The present research also recommends the use of mini slumps on the field to control mortar exudation / Mestrado / Geotecnia / Mestre em Engenharia Civil
15

Comportamento de estacas Mega de concreto, implantadas em solo colapsivel / Behavior of concrete "mega" piles, installed in collapsible soil

Donadon, Emanuelle Fazendeiro 14 August 2018 (has links)
Orientador: Claudio Vidrih Ferreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-14T15:24:59Z (GMT). No. of bitstreams: 1 Donadon_EmanuelleFazendeiro_M.pdf: 6376843 bytes, checksum: a721bbfe8b90f930873fde3fdf8d5cfe (MD5) Previous issue date: 2009 / Resumo: São muito comuns os casos de obras que tem problemas de fundações devidos ao colapso do solo e, em sua grande maioria, essas obras têm como correção o reforço de fundações com estacas "Mega" de concreto que, apesar da grande utilização, ainda existem poucos estudos sobre este tipo de estaca. Com o objetivo adicionar parâmetros ao meio técnico sobre este tipo de fundação e sobre a influência do colapso do solo em sua capacidade de carga, foi feito provas de carga em estacas "Mega" de concreto com comprimentos de 6 e 8 metros, em solo com umidade natural e pré-inundado. Com os resultados obtidos foi possível verificar que a perda na capacidade de carga neste tipo de estaca é significativa e deve ser considerada quando utilizada em solos colapsíveis. / Abstract: There are very common cases of works that have problems due to the collapse of foundations and soil, and in the most of the works, the solution applied is the underpinning with Mega piles of concrete that, despite the wide use, there are few studies on this type of foundation. With the aim of add parameters to the technical means about this type of foundation and the influence of the collapse of the soil in its load capacity, load tests were performed on concrete Mega piles with lengths of 6 and 8 meters, in soil with natural moisture and pre-flooded. With the results it was possible to verify that the decrease in the load capacity in this type of foundations is significant and should be considered when used in collapsible soils. / Mestrado / Geotecnia / Mestre em Engenharia Civil
16

Análise experimental e numérica de radiers estaqueados executados em solo da região de Campinas/SP / Experimental and numerical analysis of piled rafts executed in soil of the Campinas/SP region

Garcia, Jean Rodrigo, 1980- 25 May 2015 (has links)
Orientador: Paulo Jose Rocha de Albuquerque / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-27T16:49:40Z (GMT). No. of bitstreams: 1 Garcia_JeanRodrigo_D.pdf: 14218038 bytes, checksum: cdf7e3c252a38593da86399a1b22a73a (MD5) Previous issue date: 2015 / Resumo: Nesta pesquisa, analisou-se o comportamento de quatro radiers estaqueados, executados a partir de conjuntos de blocos compostos por estacas mecanicamente escavadas a trado, com 5 m de comprimento e 0,25 m de diâmetro (D), executados em solo de diabásio da região de Campinas/SP. Para tanto, foram executados blocos de fundação tipo radier estaqueado, compostos de uma, duas, três e quatro estacas, espaçadas de 5D. Esses blocos de fundação foram ensaiados a partir de provas de carga do tipo estática e lenta (SML), seguindo as prescrições da NBR12131/2006. As estacas foram instrumentadas em profundidade com strain-gages posicionados no topo e na ponta, com a finalidade de avaliar o mecanismo de distribuição de carga em profundidade, assim como avaliar as parcelas de contribuição de cada elemento (estaca e radier) na capacidade do radier estaqueado. Para melhor entender o comportamento desse tipo de fundação utilizou-se de análises tridimensionais (3D) por elementos finitos, por meio do software LCPC-Cesar. O modelo constitutivo utilizado foi de Mohr-Coulomb, que leva em consideração o comportamento elastoplástico do solo. Os resultados experimentais apontaram uma contribuição média devido ao contato radier-solo de 21% e 79% devido às estacas (lateral + ponta), em relação à capacidade total delas. Os resultados numéricos, justificados pela dificuldade em representar o efeito de escorregamento do contato entre o elemento de fundação e o solo, demonstraram maior participação pelo contato (36%) e menor parcela devido às estacas (64%). As análises numéricas de grupos de estacas, comparadas aos radiers estaqueados, demonstraram que a maior participação da resistência de ponta é gerada em função da existência do efeito de contato / Abstract: This research analyzed the behavior of four piled rafts executed from sets of blocks composed by mechanically augered piles. The piles, with 5m long, 0.25m diameter (D) were executed in diabase soil from the region of Campinas/SP. With this purpose, foundation blocks comprising one, two, three and four piles with spacing of 5D were executed in contact with the soil. These foundation blocks underwent slow maintained load tests (SML) per prescriptions of NBR12131/2006. The piles were instrumented at depth with strain-gages placed at the top and at the tip in order to assess the mechanism of load distribution in depth, and also to asses the percentage of contribution of each element (pile and radier) on the capacity of the piled rafts. To get a better understanding of this type of foundation, three-dimensional (3D) finite element analyses were made by means of the LCPC-Cesar software program. The constitutive model used was the Mohr-Coulomb, which takes the elastoplastic behavior of the soil in consideration. The experimental results indicated a mean contribution via contact of 21% and 79% due to the piles (lateral + tip) in comparison to their total capacity. The numerical results, justified by the difficulty to represent the effect of 'breaking' the contact between the foundation element and the soil, demonstrated greater participation of the contact (36%) and a smaller percentage due to the piles (64%). In comparison with the foundation blocks with contact, the numerical analyses from which the contact was eliminated demonstrated that the greater participation of tip resistance is generated as a function of the existence of the contact effect / Doutorado / Estruturas e Geotécnica / Doutor em Engenharia Civil