• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 1
  • 1
  • Tagged with
  • 44
  • 44
  • 44
  • 43
  • 14
  • 9
  • 9
  • 9
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Participação da via de sinalização da beta-arrestina na produção de óxido nítrico induzido pelo shear stress / Beta-arrestin-mediated signal transduction participates in laminar shear stress-induced production of nitric oxide in endothelial cells

Ana Paula Carneiro dos Santos 30 January 2015 (has links)
As células endoteliais são capazes de converter o estímulo mecânico em sinais intracelulares e produzir fatores vasoativos como o óxido nítrico (oNO). Evidências recentes sugerem que as beta-arrestinas desempenham um papel importante não somente na dessensibilização e internalização de receptores acoplados à proteína G (GPCR) como também na mecanotransdução. Nós testamos a hipótese de que células endoteliais submetidas ao shear stress (SS) produzem oNO por meio da ativação da via de sinalização dependente de beta-arrestina. Para tal, células endoteliais de veia safena (hSVEC) foram transfectadas com siRNA contra as isoformas 1 e 2 da beta-arrestina e, posteriormente, submetidas ao SS (15 dinas/cm2) durante 10 min. Nós encontramos que as SVEC silenciadas para a beta-arrestina 1/2 (70%) exibiram uma menor produção de nitrito no meio de cultura em resposta ao SS (166±17 vs. 326±44% comparado com hSVEC transfectadas com siRNA controle). Além disso, o silenciamento da beta-arrestina 1 e 2 preveniu os níveis de fosforilação da Akt no resíduo de serina 473 e a fosforilação da eNOS no resíduo de serina 1177, enquanto que a fosforilação da ERK 1/2 manteve-se inalterada. Curiosamente, análises de imunoprecipitação mostraram que a beta-arrestina interage com caveolina-1, um mecanossensor do shear stress, mas não é influenciado pelo SS. Além disso, na situação estática, a beta-arrestina encontra-se em uma localização perinuclear e, após o SS, adquiriu um padrão mais difuso no citosol. Coletivamente, esses dados sugerem que a beta-arrestina e a sinalização downstream Akt/ eNOS são necessárias para a produção de oNO induzido por shear stress em células endoteliais vasculares humana / Endothelial cells are capable of converting mechanical stimuli into intracellular signals generating vasoactive factors such as nitric oxide (oNO). Recent evidence suggests that beta-arrestins play a role not only on G protein-coupled receptors (GPCR) desensibilization but also in mechanotransduction. We tested the hypothesis that beta-arrestin and its downstream signaling influence laminar shear stress (SS)-induced oNO production by endothelial cells. Towards this end, human saphenous vein endothelial cells (hSVEC) transfected with siRNA against beta-arrestins isoforms 1 and 2 were subjected to SS (15 dynes/cm2, 10 minutes). We found that the SS-induced production of nitrite in the cell culture medium from down-expressed beta-arrestin 1/ 2 (70%) SVEC decreased (166±17 vs. 326±44% compared to wild-type hSVEC; P < 0.001). The beta-arrestin 1 and 2 down-regulation in SVEC also inhibited the phosphorylation levels of Akt at the serine residue 473 and the phosphorylation levels of eNOS at the serine residue 1177, whereas ERK phosphorylation remained unchanged. Interestingly, immunoprecipitation analysis showed that beta-arrestin interacts with caveolin-1, a shear stress mechanosensor, which is not influenced by SS despite the fact that the static perinuclear localization of beta-arrestins changed to the cytosol upon SS. Collective these data suggest that beta-arrestin and Akt/eNOS downstream signaling are required for shear stress-induced nitric oxide production in human vascular endothelial cells
22

Avaliação in vitro do colar de implantes cone Morse de diferentes diâmetros sob cargas cêntrica e excêntrica: estudo por meio da Interferometria Eletrônica por Padrões de Speckle / In vitro evaluation of the collar of Morse taper dental implants with different diameters under centric and eccentric loads: an electronic speckle pattern interferometry study

Sergio Rodrigues Sizo 15 September 2011 (has links)
Cargas oclusais excessivas podem promover tensões exageradas às estruturas de implantes/pilares/próteses, resultando em deformação, desadaptação ou mesmo fratura dos componentes e do próprio implante. Além disso, tais sobrecargas podem gerar necrose por compressão e perda óssea peri-implantar e, ainda, a ocorrência de microdeslocamentos na interface de conexão implante-pilar (I-P) ocasionando a formação de fendas propícias à colonização bacteriana, o que pode levar ao desenvolvimento de peri-implantite, contribuindo para o insucesso do conjunto. O presente estudo objetivou avaliar, por meio de uma técnica já amplamente utilizada na Engenharia e na Física a Interferometria Eletrônica por Padrões de Speckle (ESPI) as deformações a nível do colar de implantes com conexão cônica interna (cone Morse) de diferentes diâmetros (Kopp 4,3/5,5 mm e Neodent 3,5/5,0 mm), sob dois tipos (cêntrica e excêntrica) e intensidades (50 N e 100 N) de cargas, similares as quais os implantes ficam expostos durante a função mastigatória. Testou-se a hipótese de que a deformação do colar do implante seria inversamente proporcional ao diâmetro do implante. Além disso, discutiu-se vantagens e limitações da técnica ESPI frente a outros métodos comumente utilizados na avaliação de tensões. As maiores deformações foram sempre associadas às cargas excêntricas, com exceção do G1-Kopp. A maior deformação ocorreu no G1-Neodent sob carga excêntrica de 100 N e a menor, no G2-Neodent sob carga cêntrica de 50 N. A técnica ESPI mostrou-se altamente sensível e reprodutível para avaliar deformações a nivel do colar de implantes sendo possível confirmar a hipótese inicial, visto que a maior deformação esteve sempre associada aos implantes de menor diâmetro, em ambos os sistemas de implante pesquisados. / Occlusal overloading may promote excessive stresses to the implants/abutments/prosthesis, resulting in deformation, misfit or fracture of the components, until the implants. Futhermore, strains of the implant-abutment connection can cause the formation of microgaps propitious to bacterial colonization, which leads to the development of peri-implant sites, leading to the failure of the rehabilitation. This study aimed to evaluate, by a technique widely used in the engineering and physics Electronic Speckle Pattern Interferometry (ESPI) the strains related to the implant collar with internal tappered connection (Morse taper) with different diameters (Kopp 4.3/5.5 mm and Neodent 3,5/5,0 mm), under two types (centric and eccentric) and intensities (50 N and 100 N) of loads, similar which implants are exposed during masticatory function. We tested the hypothesis that the strains of the implants collar would be inversely proportional to the diameter of the implant. In addition, the survey discussed the advantages and limitations of the ESPI technique over other methods commonly used to assess strains. The largest strain was always associated with eccentric loads, except for G1-Kopp. The largest strain occurred in the G1-Neodent under the eccentric loads of 100 N and the lowest in the G2-Neodent under the centric loads of 50 N. The ESPI technique was a highly sensitive and reproducible to evaluate the strains at the level of the collar of implants being possible to confirm the initial hypothesis, since most strains was always associated with narrower-diameter implants in both implant systems studied.
23

Análise da variabilidade circadiana da temperatura oral, estresse e cronotipo em estudantes e trabalhadores do turno noturno / Analysis circadian variability oral temperature, chronotype and stress in students and workers night shift

Andreoli, Carla Parada Pazinatto, 1959- 23 August 2018 (has links)
Orientador: Milva Maria Figueiredo De Martino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-23T01:40:43Z (GMT). No. of bitstreams: 1 Andreoli_CarlaParadaPazinatto_D.pdf: 2612922 bytes, checksum: 9bd8bce829aaf9cf0113b467e4aef0e1 (MD5) Previous issue date: 2013 / Resumo: Introdução - O sistema de temporização do organismo humano se expressa pela ritmicidade de seus eventos fisiológicos e são conhecidos por ritmos biológicos ou circadianos pelo fato de imprimirem variações periódicas e comportamentais. Naturalmente, a temperatura corporal exibe uma flutuação diária que resulta da inter-relação contínua entre ritmicidade e homeostase. A sincronização dos horários depende de uma tendência individual caracterizada pelos cronótipos que são parâmetros biológicos e comportamentais apresentados com diferenças interindividuais que afetam a expressão dos ritmos circadianos. Contudo os seres humanos têm a capacidade de se adaptar a mudanças diárias, embora a vida proporcione situações que geram desequilíbrio físico e emocional. Essas manifestações são reações de estresse e refletem sobremaneira no desempenho pessoal e profissional. O estudo e o trabalho noturno são condições que propiciam o surgimento de sintomas de estresse e levam a consequências negativas para a saúde física, social, afetiva e profissional. Objetivo - Analisar a ritmicidade circadiana da temperatura oral, identificar o cronótipo e os índices de estresse em estudantes e em profissionais da enfermagem dos turnos diurno e noturno. Método - Estudo descritivo, transversal, com enfoque quantitativo e comparativo, em que participaram estudantes (n=56) e profissionais de enfermagem (n=34). Os estudantes cursavam o 3º e o 5º período do Curso de Graduação de Tecnologia em Estética e Cosmética e os profissionais da equipe de Enfermagem da Santa Casa de Misericórdia. Utilizaram-se os seguintes instrumentos: Questionário de informações pessoais; Questionário para identificação de indivíduos matutinos e vespertinos elaborado por Horne e Östberg (1976) e adaptado para o Brasil por Benedito-Silva et al. (1990) e Inventário de Sintomas de Stress de LIPP (ISSL, 1989). Para as medidas da temperatura oral usaram-se termômetros clínicos digitais de haste flexível, e as medidas foram verificadas a cada três horas pelos dois grupos do estudo. Resultados - Observaram-se para o tempo de trabalho entre os profissionais de enfermagem o valor médio de 10,9 anos (dp±8,4) e para os estudantes trabalhadores valores médios de 10,1 anos (dp±9,6), demonstrando diferença significante (p<0.0001). Verificou-se quanto ao gênero, para o grupo de estudantes 96.43% do sexo feminino e 82,35% para os profissionais de enfermagem. Os resultados da temperatura oral, dos estudantes do período da manhã, demonstraram os seguintes parâmetros: Mesor = 36.4609, Amplitude = 0.2335 e a Acrofase =14.4658, com (p - valor = 0.0009) e para os profissionais de enfermagem: Mesor = 36.2196, Amplitude = 0.4007e a Acrofase =15.0746, com (p - valor < 0.0001). A comparação entre os cronotipos e as fases do estresse mostrou dados significantes pelo (Teste Fisher, p=0.0311). As comparações dos sintomas do estresse entre os grupos demonstraram dados significantes (Teste Fisher, p=0.0139). Conclusão. Observou-se que a curva da temperatura ajustou se a uma curva senoide demonstrando ritmicidade circadiana. Para a classificação do cronotipo obteve-se prevalência do tipo indiferente para a equipe de enfermagem e para os estudantes o tipo vespertino. Verificou-se a presença de sintomas de estresse físicos para a enfermagem e os sintomas psicológicos nos estudantes / Abstract: Background: The time system of the human body is expressed by the rhythmicity of its physiological events and known by biological or circadian rhythms by the fact of producing periodical and behavioral variations. The body temperature naturally exhibits a daily fluctuation resulting from the continuous interrelationship between rhythmicity and homeostasis. The time synchronization depends on an individual trend characterized by chronotypes, which are biological and behavioral parameters presented with interindividual differences that affect the expression of circadian rhythms. However, human beings are capable of adapting to daily changes, although life may provide situations that generate physical and emotional imbalance. These manifestations are stress reactions and reflect greatly on personal and professional performance. Study at night and night work shift are conditions that favor the appearance of stress symptoms and lead to negative consequences for physical, social, emotional, and professional health. Objective: Analyze circadian rhythmicity of oral temperature, identify the chronotypes and stress indexes in students and nursing professionals of day and night shifts. Method: A quantitative descriptive transverse quantitative approach and comparative study comprising students (56) and nursing professionals the (34). The students attended the 3th and 5th periods at the undergraduate course in esthetics and cosmetics technology, and the nursing professionals worked at the Santa Casa de Misericórdia. The following instruments were used: personal information questionnaire; questionnaire for identification of morning and afternoon individuals elaborated by Horne and Östberg (1976) and adapted to Brazil by Benedito-Silva et al. (1990); and LIPP stress symptom inventory (ISSL, 1989). Digital clinical thermometers of flexible stem were used for measuring oral temperature, and measurements were verified every three hours in the two groups of study. Results: Working time among nursing professionals observed a mean of 10.9 years (SD ± 8.4) and for the students workers average of 10.1 years (SD ± 9.6), demonstrating a significant difference (p <0.0001). It was observed that belong to females 96.43% for the group of students and 82.35% for nursing professionals. The results of oral temperature, students of the morning, showed the following parameters: 36.4609 = mesor, amplitude and acrophase = 0.2335 = 14.4658 with (p - value = 0.0009), and nursing professionals: mesor = 36.2196, Amplitude = 0.4007 and acrophase = 15.0746 with (p - value <0.0001). Associations between the chronotype and stress phases generally showed significant data (Fisher's exact test, p = 0.0311). Comparisons of stress symptoms between the groups, it was observed that significant data (Fisher's exact test, p =0.0139). Conclusion: It was observed that the temperature curve fitted to a sine curve showing circadian rhythmicity. For the classification of chronotype was obtained prevalence of type indifferent to the nursing profissionals and students the type evening. It is the presence of physical symptoms of stress for nursing and psychological symptoms in students / Doutorado / Enfermagem e Trabalho / Doutora em Ciências da Saúde
24

Avaliação das tensões e do destorque de parafusos : influência do desajuste marginal e dos tipos de metais em infraestruturas protéticas retidas por implantes / Stress distribution and screw detorque analysis: : influence of misfit and alloy types in cast implant retained frameworks

Tramontino-Mesquita, Vanessa Silva, 1982- 02 October 2012 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T17:02:54Z (GMT). No. of bitstreams: 1 Tramontino-Mesquita_VanessaSilva_D.pdf: 1263598 bytes, checksum: 21599a6e0153542032add63750d48770 (MD5) Previous issue date: 2012 / Resumo: O objetivo neste estudo foi avaliar a distribuição das tensões geradas aos implantes modificados, por meio de análise extensométrica e força de destorque dos parafusos de retenção protética, de acordo com o tipo de metal da infraestrutura (Titânio comercialmente puro - Ti c.p ou Cobalto-Cromo - Co-Cr) e presença ou ausência de desajuste vertical padronizado. Um modelo metálico foi confeccionado, simulando uma mandíbula edêntula. Cinco análogos de pilares multi-unit foram fixados ao modelo metálico, posicionados de forma a reter uma prótese fixa total sobre implantes. Dez infraestruturas em titânio c.p. e 10 infraestruturas em Co-Cr foram obtidas através de fundição em monobloco. Cada infraestrutura originou dois modelos para mensuração, um adaptado e outro desadaptado em relação aos análogos. Para a obtenção dos modelos desadaptados, anéis metálicos de espessuras conhecidas (100, 200 e 300 ?m) foram posicionados entre a infraestrutura e seus análogos correspondentes. As infraestruturas foram distribuídas entre os grupos de tratamento (n=10): G1: Titânio adaptada; G2: Titânio desadaptada; G3: Co-Cr adaptada; G4: Co-Cr desadaptada. Em todos os casos, as infraestruturas foram fixadas aos análogos com torque de 10 N.cm com torquímetro digital. A força de destorque foi avaliada com torquímetro digital e o desajuste vertical, avaliado por meio de microscópio óptico (aumento de 120x), pelo teste do parafuso único. Extensometria foi utilizada para determinar as tensões geradas às fixações. As médias e desvio padrão de desajuste (?m) foram G1: 36,63 (15,84), G2: 174,45 (33,64), G3: 43,25 (14,06) e G4: 173,18 (24,45) (ANOVA e Tukey; alfa=5%), havendo diferença entre adaptados e desajuste, porém sem diferença entre Ti e Co-Cr. Não houve diferença entre os metais para tensão induzida aos implantes, mas maiores valores de desajuste promoveram maior tensão (ANOVA e Tukey; alfa=5%). Houve forte correlação positiva entre desajuste e tensão (Coeficiente de Correlação de Pearson, r=0,7475 e p<0,0001) e moderada correlação positiva entre desajuste e destorque (Coeficiente de Correlação de Pearson, r=0,3357 e p=0,0341). Para tensão e destorque, houve fraca correlação positiva (Coeficiente de Correlação de Pearson, r=0,2146 e p=0,1834). Pode-se concluir que próteses desadaptadas, independentemente do tipo de liga, promovem aumento nos valores de tensão aos implantes, mas não influenciam na força de destorque de parafusos protéticos / Abstract: This study evaluated stress induced on the implants using strain gauges analysis, and detorque loads of titanium prosthetic screws according to the type of the framework metal (c.p. Titanium or Cobalt-Chromium) and to the presence or absence of misfit. A metallic master model was fabricated, simulating an edentulous patient mandible. Five multi-unit abutment analogues were fixed on the master model, placed as though they would support a total fixed prosthesis. Ten c.p. titanium and 10 cobalt-chromium frameworks were obtained by 1-piece casting. Each framework created 2 measurement models, one passive fitted and the other misfitted to the analogues. To obtain the misfitted measurement models, metallic rings with known thickness (100, 200 and 300 ?m) were positioned between the framework and its analogues. Frameworks were distributed to treatment groups (n=10): G1: Titanium Passive Fit; G2: Titanium Misfit; G3: Cobalt-Chromium Passive Fit; and G4: Cobalt-Chromium Misfit. All infrastructures were screwed to their analogues using a digital torquimeter, with a torque of 10 N.cm. Detorque was assessed with a digital torquimeter, and misfit was evaluated by an optical microscope (120 X) according to the one-screw test. Strain gauges were used to determine stress generated on the fixations. Misfit mean values (?m) were G1: 36.63 (15.84), G2: 174.45 (33.64), G3: 43.25 (14.06) e G4: 173.18 (24.45), presenting difference between passive fit and misfit however no difference was found between the metals (ANOVA and Tukey; alfa=5%). There was no difference between materials for stress induced upon implants, but a higher level of misfit promoted higher values of stress (ANOVA and Tukey; alfa=5%). There was a strong positive correlation between fit and stress (Pearson's Correlation Coefficient, r=0.7475 and p<0.0001), and a moderate correlation between fit and detorque (Pearson's Correlation Coefficient, r=0.3357 and p=0.0341). For stress and detorque, there was a weak positive correlation (Pearson's Correlation Coefficient, r=0.2146 and p=0.1834). Misfitted prostheses, regardless of the metal type, promote high rates of stress to the implants, but do not influence the detorque of prosthetic screws / Doutorado / Protese Dental / Doutor em Clínica Odontológica
25

Distribuição das tensões em regiões perimplantares em dois implantes comerciais (Ti e TiZr) de pequeno diâmetro: estudo fotoelástico / Distribution of stress in peri-implant regions in two commercial inplants (Ti and TiZr) small diameter: photoelastic study

Tatiana de Andrade Sabino 25 November 2014 (has links)
Objetivo: Avaliar a distribuição de tensões nas regiões periimplantares dos implantes de titânio (TiCP) e titânio- zircônio (TiZr), de pequeno diâmetro (3,3mm) e comprimento de 12mm, decorrentes de cargas axiais e oblíquas. Método: Foram confeccionados dois modelos fotoelásticos, sendo um com um implante de TiCP e o outro com um implante de titânio-zircônio (TiZr). Sobre os pilares de cicatrização foram aplicadas cargas axiais com angulações de 0, 10, 20 e 30, de 100N e 200N, em relação ao longo eixo do implante, por meio da máquina universal de ensaio conjugada ao polariscópio circular na configuração de campo escuro. As franjas isocromáticas foram analisadas nas regiões periimplantares, nas condições testadas. Resultados: Com angulações de 0 e 10, o implante de TiZr apresentou tensões menores em 80% das situações quando comparado com o implante de TiCP. Com angulação de 20, o TiZr apresentou tensões menores em 10% e com 30 de inclinação o TiZr apresentou tensões menores em 60% das áreas perirradiculares analisadas. Conclusões: O implante de TiZr apresentou tensões menores quando comparado com o TiCP na maioria das regiões avaliadas. / Objective: To evaluate the stress distribution in peri-implant regions of implants with pure titanium and titanium-zirconium (TiZr), small diameter (3.3mm) and a length of 12mm, resulting from axial and oblique loads. Method: Two photoelastic models were made, one with an implant TiCP and the other with an implant Titanium-Zirconium (TiZr) with 15% zirconium in its composition. On the healing abutments centered axial load and oblique 10, 20 and 30 (100N and 200N) to the long axis of the implant were applied by means of a universal testing machine coupled to the circular polariscope field configuration dark. The isochromatic fringes were analyzed in the peri-implant regions, in the tested conditions. Results: With angles of 0 and 10, the implant had lower stress TiZr in 80% of cases compared with the implant cpTi. With angle of 20, the TiZr had lower stress by 10% and with 30 tilt the TiZr had lower stress in 60% of periradicular areas analyzed. Conclusions: The presented implant TiZr showed lower stress compared to the rated cpTi in most regions.
26

Avaliação biomecânica da técnica onlay para reconstrução do ligamento cruzado posterior: comparação entre as fixações unicortical e bicortical do enxerto na tíbia / Onlay reconstruction of the posterior cruciate ligament: biomechanical comparison of unicortical and bicortical tibial fixation

II, João Bourbon de Albuquerque 21 May 2018 (has links)
As lesões do ligamento cruzado posterior (LCP) geralmente estão associadas a traumas de alta energia. Ainda existem muitas controvérsias sobre a técnica cirúrgica ideal para o tratamento dessas lesões, no que diz respeito aos métodos de seleção e fixação do enxerto. A técnica onlay, recentemente descrita, permite a fixação direta de um autoenxerto de tendões flexores ao aspecto posterior da tíbia com parafuso esponjoso e arruela dentada plástica, com proteção às estruturas neurovasculares e evitando a chamada \"curva assassina\". O objetivo deste estudo foi realizar uma avaliação biomecânica da técnica onlay, comparando entre si as fixações tibiais unicortical e bicortical de enxertos, imediatamente após o implante (tempo zero). O ensaio biomecânico e a coleta de dados foram realizados no Thompson Laboratory for Regenerative Orthopaedic da Universidade de Missouri (Columbia, Missouri, EUA). Para isso, oito joelhos de espécimes cadavéricos foram distribuídos aleatoriamente em uma das duas técnicas de fixação do LCP (n = 4 joelhos/técnica), que foram realizadas por cirurgiões experientes no procedimento. O teste biomecânico consistiu em uma força com direção posterior aplicada a região proximal da tíbia, em quatro ângulos de flexão do joelho, 10o, 30o, 60o e 90o. O teste foi realizado com uma taxa de deslocamento de 1 mm/s, em uma máquina servo-hidráulica (8821s, Instron, Norwood, MA). As variáveis medidas foram: carga para 5 mm de deslocamento posterior, deslocamento máximo (com carga de 100 N) e rigidez. Para a análise estatística, os dados de cada joelho foram normalizados para o joelho com LCP nativo intacto e depois agrupados nas categorias unicortical ou bicortical, de acordo com a fixação realizada. Dados obtidos, nas variáveis mencionadas, para os grupos joelho intacto, joelho desbridado, unicortical e bicortical, foram comparados por meio da análise de variância simples (one-way ANOVA) para avaliar diferenças estatisticamente significativas (p < 0,05). Quando comparadas aos joelhos com LCP desbridado, as técnicas de fixação unicortical e bicortical apresentaram menor frouxidão a uma carga máxima de 100N. Quando comparados com os joelhos intactos, o grupo unicortical apresentou maior frouxidão em todos os ângulos e o grupo bicortical apresentou maior frouxidão apenas a 90o de flexão (p < 0,001). Na avaliação da força relativa do enxerto, ou seja, a carga necessária para atingir 5 mm de deslocamento na gaveta posterior, as técnicas unicortical e bicortical exigiram menos carga que os joelhos com LCP intacto. O grupo com fixação bicortical, no entanto, foi superior ao unicortical em todos os ângulos (p < 0,001), na avaliação da força relativa. Em relação à rigidez, não houve diferenças significativas entre os grupos unicortical e bicortical e ambos foram superiores aos joelhos desbridados e inferiores aos joelhos com LCP intacto. Com base nos testes biomecânicos de cadáveres, nenhuma das técnicas de reconstrução do LCP foi capaz de reproduzir os resultados do joelho com LCP intacto, mas ambas as técnicas foram superiores aos joelhos com deficiência de LCP. Ao se optar pela técnica onlay de reconstrução do LCP, a técnica de fixação tibial bicortical parece ter vantagens biomecânicas em relação à técnica de fixação unicortical. / Posterior cruciate ligament (PCL) injuries are generally associated with high energy trauma. There are many controversies regarding optimal surgical technique in regard to graft selection and fixation methods. The recently described onlay technique allows for direct fixation of a hamstring autograft to the posterior aspect of the tibia, protecting the neurovascular structures and avoiding the so-called \"killer turn\". The onlay technique requires a cancellous screw and spiked washer to secure the graft to the tibia. The objective of this study was to compare immediate post-implantation biomechanics of unicortical versus bicortical tibial fixation of onlay PCL grafts. Biomechanical testing and data collection were performed at the Thompson Laboratory for Regenerative Orthopedics at the University of Missouri (Columbia-Missouri-USA). For that, eight knees were randomly assigned to one of two onlay PCL techniques (n= 4 knees/technique), performed by surgeons experienced with the procedure. Testing consisted of a posterior-directed force at four knee flexion angles, 10, 30, 60, and 90 degrees, at a displacement rate of 1 mm/s, performed in a servo-hydraulic machine (8821s, Instron, Norwood, MA). Measured variables were: load to 5 mm of posterior displacement, maximum displacement (at 100 N load) and stiffness. For statistical analyses, data for each knee were normalized to the native PCL-intact knee and then grouped into unicortical or bicortical groups accordingly. Data for load to 5 mm (strength), displacement at 100 N, and stiffness were compared among PCL-intact, PCL-deficient, unicortical fixation, and bicortical fixation categories using one-way analysis of variance (ANOVA) to assess for statistically significant (p < 0.05) differences. When compared to PCL-deficient knees, both unicortical and bicortical fixation techniques had less laxity at a maximum load of 100N. When compared with PCL-intact knees, unicortical had more laxity at all angles and bicortical had more laxity only at 90 degrees (p < 0.001). For relative graft strength, namely the load required to reach 5mm of displacement in posterior drawer, unicortical and bicortical techniques required less load to 5 mm of posterior drawer than for PCL-intact knees. Bicortical, however, outperformed unicortical at all angles (p < 0.001) for relative strength. Regarding stiffness of each construct, there were no significant differences between unicortical and bicortical and both were superior to PCL-deficient and inferior to PCL-intact knees. Based on cadaveric biomechanical testing, none of the reconstructed PCL knees was able to replicate the intact native PCL, but both techniques were superior to PCLdeficient knees. The bicortical tibial fixation technique appears to have biomechanical advantages when opting for onlay PCL reconstruction.
27

Análise biomecânica e histológica do colo do aneurisma da aorta abdominal infrarrenal: estudo em necrópsia / Biomechanical and histological analysis of the infrarenal abdominal aortic aneurysm neck: a necropsy study

Queiroz, Andre Brito 04 November 2015 (has links)
INTRODUÇÃO: O colo dos aneurismas da aorta abdominal infrarrenal é o principal local de interação entre a parede aórtica e as próteses utilizadas no seu tratamento, pela técnica aberta ou endovascular. A dilatação do colo no acompanhamento pósoperatório, levando a falhas no tratamento, demonstra a importância de um colo confiável para um reparo eficiente em longo prazo. OBJETIVOS: Determinar as propriedades biomecânicas e histológicas do colo do aneurisma da aorta abdominal infrarrenal, comparando os resultados com as propriedades da aorta suprarrenal e da parede anterior do aneurisma. MÉTODOS: Dezesseis aneurismas da aorta abdominal infrarrenal encontrados em necrópsia foram removidos e dissecados em laboratório. A anatomia original dos aneurismas foi restabelecida com o auxílio de um balão complacente inserido na luz dos espécimes, sendo que aneurismas com um colo mais curto que 10 mm foram excluídos. Fragmentos transversais similares da parede anterior do aneurisma, do colo e da aorta suprarrenal foram obtidos com o auxílio de um dispositivo de corte apropriado. Testes de tração uniaxiais destrutivos foram realizados para a obtenção das seguintes propriedades biomecânicas: tensão, estresse, energia de deformação e deformação no momento da falência, além da medida da espessura dos fragmentos. A análise histológica destes fragmentos consistiu na quantificação das fibras colágenas, elásticas e espessura da camada média. RESULTADOS: Em doze aneurismas rotos e quatro não rotos, a análise biomecânica dos fragmentos de tecido arterial não demonstrou diferenças estatisticamente significativas entre os valores médios das propriedades biomecânicas de falência (tensão, estresse, energia de deformação e deformação), assim como para a espessura nos três segmentos estudados. O percentual de colágeno para o colo foi significativamente menor que na parede dos aneurismas (p = 0,010) e não foi significativamente diferente da aorta suprarrenal (p = 0,155). A elastina apresentou percentual significativamente maior no colo (p < 0,001) e na aorta suprarrenal (p < 0,001) quando comparados aos aneurismas. Não houve diferença na quantificação da elastina entre o colo e o segmento suprarrenal (p = 0,457). A espessura da camada média não apresentou diferença estatística relevante entre as três regiões avaliadas (p = 0,660). CONCLUSÕES: Os resultados biomecânicos sugerem que o aneurisma da aorta infrarrenal, ao invés de uma processo localizado, seja resultado de um acometimento aórtico difuso. Tanto a resistência quanto a elasticidade do segmento aneurismático apresentam semelhanças quando comparados aos segmentos aórticos não dilatados. Na análise histológica, nota-se preservação da elastina nos segmentos aórticos não dilatados, enquanto há redução na parede aneurismática; além de maior deposição de colágeno nesta região / INTRODUCTION: The neck of the infrarenal abdominal aortic aneurysm is the principal site of interaction between the aortic wall and the devices used in the repair of these aneurysms, by open or endovascular technique. Postoperative aneurysm neck dilation leading to aneurysm exclusion failures demonstrates the importance of a reliable neck for the long-term efficient repair. OBJECTIVE: To access the biomechanical and histological properties of the infrarenal aortic aneurysm neck, comparing the results with the properties of the suprarenal aorta and the anterior wall of the aneurysm. METHODS: Sixteen infrarenal abdominal aortic aneurysms found in necropsies were removed and dissected in laboratory. The original anatomy of the aneurysms was restored with the aid of a compliant balloon inserted in the specimens lumen and aneurysms with a neck shorter than 10 mm were excluded. Similar transverse fragments from the anterior aneurysm wall, aneurysm neck, and suprarenal aorta were obtained with the aid of a cutting device. Uniaxial destructive tensile tests were performed to obtain the following biomechanical properties: tension, stress, strain energy and strain at the moment of fragment failure, and the thickness of the fragments. Histological analysis was performed with the quantification of collagen and elastin, and middle layer thickness in these three fragments. RESULTS: In twelve ruptured and four unruptured aneurysms, the biomechanical analysis of the fragments showed no statiscally signicant differences between the mean values of the biomechanical properties (tension, stress, strain energy and strain), as well as the thickness of the fragments in the three groups. The percentage of collagen in the neck was significantly lower than in the aneurysm wall (p = 0,010) and was not significantly different from the suprarenal aorta (p = 0,155). Higher percentage of elastin was present in the neck (p < 0,001) and in the suprarenal aorta (p < 0,001) when compared to aneurysms. There was no difference in the quantification of elastin between the neck and the suprarenal segment (p = 0,457). The middle layer thickness showed no significant statistical difference between the three evaluated regions (p = 0,660). CONCLUSIONS: Biomechanical results suggest that the infrarenal aortic aneurysm, rather than a localized process, is a result of diffuse aortic involvement. Both the resistance and elasticity of the aneurysmal segment have similarities when compared to non-dilated aortic segments. In the histological analysis, there is preservation of elastin in non-dilated aortic segments, while there is a reduction in the aneurysmal wall; and there is greater collagen deposition in the aneurysmatic region
28

Estudo das propriedades histológicas e biomecânicas de fragmentos da parede anterior de aneurismas da aorta abdominal / Study of the histological and biomechanical properties of fragments isolated from the anterior wall of abdominal aortic aneurysms

Monteiro, José Augusto Tavares 15 March 2013 (has links)
INTRODUÇÃO: O objetivo deste estudo é determinar as propriedades biomecânicas e histológicas de fragmentos da parede anterior de aneurismas da aorta abdominal. MÉTODOS: Dos pacientes submetidos à correção cirúrgica aberta de aneurisma da aorta abdominal, foram removidos fragmentos da parede anterior do saco aneurismático, divididos em dois espécimes. Um, destinado à análise histológica, para a quantificação de fibras colágenas, elásticas, musculares lisas e grau de atividade inflamatória e outro, pareado, submetido a teste destrutivo uniaxial, obtendo-se características biomecânicas, como, força, tensão e estresse de falência do fragmento. As médias das variáveis paramétricas foram avaliadas com teste t-Student ou análise de variância. Quando significante, utilizou-se teste de Tukey para discriminar as diferenças. As distribuições das variáveis não paramétricas foram avaliadas com teste Mann-Whitney ou análise de Kruskal-Wallis. Quando significante, utilizou-se teste de Dunn para discriminar as diferenças. Os valores de p<0,05 foram considerados estatisticamente significantes. RESULTADOS: Foram considerados os resultados das análises de fragmentos de 90 indivíduos. Os valores médios encontrados para as propriedades biomecânicas relacionadas à resistência do tecido aórtico (falência) foram força = 4,98±2,22 N, tensão = 13,18±5,98 N/cm e estresse = 103,14±47,09 N/cm2. A deformação média dos fragmentos até a falência foi de 0,39±0,12. Os fragmentos dos aneurismas de diâmetros transversos máximos maiores ou iguais a 5,5 cm apresentaram valores médios de força, tensão e estresse de falência (5,32±2,07 N, 13,83±5,58 N/cm e 103,02 N/cm2) maiores que os fragmentos de aneurismas de diâmetros menores que 5,5 cm (4,1±2,41 N, 10,82±6,48 N/cm, 77,03 N/cm2), com significância estatística para os três parâmetros de resistência do material. Não foram identificadas diferenças entre os valores médios de deformação de falência entre estes grupos (0,41±0,12 x 0,37±0,14 p = 0,260), bem como entre os valores médios de espessura dos fragmentos (1,58±0,41 x 1,53±0,42 mm p = 0,662). Os valores percentuais médios na composição dos fragmentos foram para as fibras colágenas (coloração de tricrômico de Masson) de 44,34±0,48%, para as fibras colágenas (coloração de picrosirius) de 61,85±10,14%, para as fibras musculares lisas (imuno histoquímica/alfa actina) de 3,46±2,23% e para as fibras elásticas (coloração de Verhoeff) inferior a 1% (traços). Não foram identificadas diferenças entre o percentual destes elementos na composição de fragmentos provenientes da parede anterior de aneurismas de diâmetro transverso máximo >= 5,5 cm e < 5,5 cm. Foi caracterizada uma atividade inflamatória mais intensa nos fragmentos provenientes de aneurismas de diâmetro transverso máximo >= 5,5 cm quando comparados aos fragmentos provenientes de aneurismas de diâmetro transverso máximo < 5,5 cm (grau 3 - 70% x 28,6% p = 0,011). Comparando-se os aneurismas sintomáticos versus os assintomáticos não foram identificadas diferenças significativas para as propriedades biomecânicas de falência dos fragmentos (força = 5,32±2,36 x 4,65±2,05 N, p = 0,155; tensão = 14,08±6,11 x 12,81±5,77 N/cm, p = 0,154; estresse = 103,02 x 84,76 N/cm2, p = 0,144 e deformidade = 0,38±0,12 x 0,41±0,13, p = 0,287), assim como para a espessura (1,56±0,41 x 1,57±0,41 mm p = 0,848) e composição histológica (fibras colágenas 44,67±11,17 x 44,02±13,79 % p = 0,808; fibras musculares lisas 2,52 x 2,35 %, p = 0,751; fibras elásticas inferior a 1%). CONCLUSÃO: Os fragmentos provenientes da parede anterior do saco aneurismático de aneurismas maiores mostraram-se mais resistentes, não se identificando diferenças entre os fragmentos quanto à espessura e conteúdo da matriz protéica. A maior resistência dos fragmentos de aneurismas maiores provavelmente está relacionada à adaptação da parede para suportar maior grau de sobrecarga hemodinâmica à medida que o diâmetro aumenta. Neste estudo esta adaptação não foi revelada pela análise histológica realizada e demonstra a limitação do estudo de fragmentos isolados de aneurismas para estimar o risco de ruptura dos mesmos / INTRODUCTION: The objective of this study was to determine the biomechanical and histological properties of fragments isolated from the anterior wall of abdominal aortic aneurysms. METHODS: Fragments of the anterior aneurysm wall were excised from the aneurysmatic sac of patients who underwent open surgery for repair of abdominal aortic aneurysm and divided into two specimens. One specimen was sent for histological analysis for quantification of collagen fibers, elastic fibers, smooth muscle cells and degree of inflammatory activity and the other, by uniaxial testing, was used to assess biomechanical properties, such as force, tension, and stress at the time of failure of the material. The means of parametric variables were evaluated with Student\'s t test or analysis of variance. When significant, we used the Tukey test to discriminate differences. The distributions of non-parametric variables were evaluated with Mann- Whitney or Kruskal-Wallis test. When significant, we used Dunn\'s test to discriminate differences. A p-value of less than 0.05 was considered statistically significant. RESULTS: Anterior-wall fragments from a total of 90 patients were considered. The average values of biomechanical parameters related to the resistance of the aorta (failure) were as follows: strength, 4.98±2.22 N; tension, 13.18±5.98 N/cm; and stress 103.14±47.09 N/cm2. The average deformation of the fragments at the time of the failure was 0.39±0.12. Fragments of aortic aneurysm with a maximum transverse diameter larger or equal to 5.5 cm showed average values for strength, tension, and stress at the time of the failure of the material (5.32±2.07 N, 13.83±5.58 N/cm, and 103.02 N/cm2, respectively), which were higher than those of fragments of aneurysms with diameters less than 5.5 cm (4.1±2.41 N, 10.82±6.48 N/cm, 77.03 N/cm2, respectively). The differences in the 3 parameters were statistically significant. However, no differences were observed between the groups in relation to average failure deformation (0.41±0.12 × 0.37±0.14; p = 0.260) and thickness of the analyzed fragments (1.58±0.41 × 1.53±0.42 mm; p = 0.662). The average values of fiber compositions of the fragments were as follows: collagen fibers, 44.34±0.48% and 61.85±10.14% (assessed using Masson trichrome staining and picrosirius red staining, respectively); smooth muscle cells, 3.46±2.23% (immunohistochemistry/alpha-actin); and elastic fibers, less than 1% (traces) (Verhoeff-van Gieson staining). No differences in fiber percentages were observed in the fragments from aneurysms with a maximum transverse diameter >= 5.5 cm and < 5.5 cm. A more intense inflammatory activity was assessed in fragments from aneurysms with maximum transverse diameter >= 5.5 cm than in fragments from aneurysms with maximum transverse diameter < 5.5 cm (grade 3 - 70% × 28.6%; p = 0.011). Compared to asymptomatic aneurysms, fragments from symptomatic aneurysms showed no significant differences in the biomechanical properties at the time of the failure (strength, 5.32±2.36 × 4.65±2.05 N, p = 0.155; tension, 14.08±6.11 × 12.81±5.77 N/cm, p = 0,154; stress, 103.02 × 84.76 N/cm2, p = 0.144; and deformity, 0.38±0.12 × 0.41±0.13, p = 0.287), thickness of the fragments (1.56±0.41 × 1.57±0.41 mm, p = 0.848) and histological composition (collagen fibers, 44.67±11.17 × 44.02±13.79%, p = 0.808; smooth muscle fibers, 2.52 × 2.35%, p = 0.751; elastic fibers, <1%). CONCLUSION: Fragments of the anterior wall removed from the aneurysmatic sac of large aneurysms appeared to be more resistant than those from small aneurysms. No differences between the aneurysm fragments were observed with respect to thickness and matrix protein content. The high resistance of fragments of larger aneurysms is probably attributable to the adaptation of the wall to support a high hemodynamic stress as the diameter of the aorta increases. In this study, this adaptation was not shown by histological analysis. This suggests a limitation of this study for assessing the risk of rupture based on isolated aneurysm fragments
29

Avaliação in vitro da transmissão de carga oclusal em próteses sobre implantes em função da inclinação de implantes através de análise fotoelástica / In vitro evaluation of occlusal load transmission in prosthetic implant according to the inclination of implants by photoelastic analysis

Takeshita, Edson Koji 01 September 2011 (has links)
A técnica All-on-Four foi idealizada visando diminuir a extensão do cantilever nas reabilitações de pacientes edêntulos com próteses implantossuportadas. Contudo, ainda persistem questionamentos relacionados ao comportamento biomecânico dos implantes e da própria técnica All-on-Four, posto que, questões como a perda óssea peri-implantar e falência de componentes da prótese ainda não estão claramente elucidadas. O objetivo da pesquisa foi avaliar a dissipação de tensões em próteses implantossuportadas dos tipos Branemark e All-on-Four, sob carga oclusal estática, e o papel do lado de balanceio e do comportamento do complexo implantes/próteses. Foram confeccionadas seis réplicas de mandíbula humana em resina fotoelástica, divididas em dois grupos:um com quatro implantes dispostos axialmente e paralelas entre si no espaço interforaminal (mandíbulas Branemark), e outro com quatro implantes inseridos de acordo com a técnica All-on-Four. Confeccionou-se uma prótese total implantossuportada, de maneira que se adaptasse em todas as seis mandíbulas. O experimento foi conduzido com o auxílio de um dispositivo giratório de carga, que permitiu a visualização das mandíbulas por todos os ângulos, sem alteração da carga aplicada. Após a fixação padronizada do corpo de prova no dispositivo, a prótese foi parafusada sobre os implantes da mandíbula. Os carregamentos de carga foram feitos em três pontos: no cantilever da prótese, no primeiro pré-molar e na incisal dos incisivos centrais inferiores. Para cada ponto de aplicação das cargas, fotografaram-se as mandíbulas nos lados de trabalho, de balanceio e na linha mediana, vestibular e na linha mediana também por lingual. Pelos resultados observados, quando as cargas foram aplicadas em regiões mais anteriores da prótese, as tensões nos implantes distais inclinados atenuaramse e as outras regiões da mandíbula apresentaram tensões menores e melhor distribuídas. As franjas também mostraram que a angulação dos implantes distais promoveu mudanças no eixo de rotação do conjunto implantes/prótese. Assim como verificou-se que o implante mais distal do lado de balanceio mostrou atuação conjunta com o implante distal do lado de trabalho nas mandíbulas com implantes axiais e, o mais distal do lado de balanceio nas mandíbulas com implantes inseridos segundo a técnica All-on-Four, mostrou tensão nos ápices, denotando função de estaca. Pela metodologia empregada foi possível concluir que, uma prótese total implantossuportada, segundo a técnica All-on-Four, apresentou melhor melhor dissipação das cargas oclusais e o lado de balanceio teve papel fundamental no auxílio à dissipação de cargas oclusais. / The All-on-Four technique was conceived in order to decrease the length of the cantilever in the rehabilitation of edentulous patients with implant-supported prosthesis. However, still persist questions related to the biomechanical behavior of implants and the proper technique All-on-Four, since issues such as peri-implant bone loss and failure of the prosthetic components are not yet clearly elucidated. The purpose of the study was to evaluate the dissipation of tensions in the Branemark implant-supported prosthesis and All-on-Four, under static occlusal load, and the role of the balancing side and the complex behavior of implants / prostheses. Six replicas of the human mandible were made in photoelastic resin, divided into two groups: one with four implants placed axially and parallel to each other in interforaminal space (Branemark jaws), and another four implants inserted according to the All-on-Four technique. It was made an implant-supported denture, so that would fit in all six jaws. The experiment was conducted with the aid of a rotating load device, which permitted visualization of the jaws from all angles, without changing the applied load. After the standardized setting of specimen in the device, the prosthesis was screwed onto the implants in the jaw. The cargo shipments were made on three points: the cantilever prosthesis, in the first premolar and the lower central incisor incisal. For each point of application of loads, photograph was taken from the work sides of the jaws, balancing and the midline, bucal view and the midline lingual also. By the observed results, when loads were applied to more anterior regions of the prosthesis, the stresses in the distal inclined implants attenuated and other regions of the mandible showed lower stresses and better distributed. The fringes also showed that the angulation of the distal implants promoted changes in the axis of rotation of the implant / prosthesis. As it was found that the most distal implantat on the balancing side showed joint action with the distal implant of the working side in the jaw with axial implants, and the most distal implant on the balancing side of jaw with implants inserted according to All-on Four technique, the tension showed apices, denoting stake function. For the methodology it was concluded that an implant-supported denture, according to the All-on-Four technique, had a better dissipation of occlusal loads and balancing side was fundamental hole in helping to dissipate occlusal loads.
30

Ossos do ofício: análise de marcadores de estresse ocupacional em séries esqueléticas da Baixada Santista - SP / Analysis of occupation stress markers in skeletal series of shellmounds of Baixada Santista - SP

Stabile, Rafael Amaral 19 July 2017 (has links)
As últimas décadas viram ser publicados diversos trabalhos que se debruçaram sobre aspectos paleopatológicos de séries esqueléticas de sítios do tipo sambaqui. Tal como o litoral Sul e o restante do Sudeste, o seguimento paulista da costa brasileira apresenta grande quantidade de sítios do tipo sambaqui que guardam em si um grande potencial informativo. Entretanto, no levantamento realizado por Mendonça de Souza e colaboradores (2009) sobre os aspectos paleopatológicos dos sambaquis brasileiros, salienta-se a escassez de dados sobre as séries paulistas, que quando aparecem na literatura em geral restringem-se à duas ou três séries melhor estudadas. O presente estudo, de caráter exploratório, procurou gerar dados sobre o modo de vida dos grupos construtores de sambaquis do litoral de São Paulo, a partir dos padrões de ocorrência e distribuição dos sinais indicativos de osteoartrose. As articulações sinoviais de 48 indivíduos provenientes de dois sambaquis litorâneos da Baixada Santista foram analisadas quanto a frequência e distribuição dos seguintes sinais de osteoartrose: porosidade; eburnação; erosão; exostoses superficiais; labiamentos e osteófitos, considerando sua ocorrência diferenciada entre superfície e bordo da área articular. As séries estudadas apresentaram prevalências elevadas dos marcadores na maioria das áreas articulares destacadas. Os dados apontam para uma caracterização da osteoartrose nestas populações como um processo generalizado a nível populacional e individual e reforçam a interpretação vigente de que os grupos sambaquieiros devem ter exercido um domínio generalizado sobre as fontes alimentares e recursos necessários para a reprodução da vida material cotidiana. / The past decades witnessed the publication of several papers that dealt with paleopathological aspects of skeletal series of shellmoun-builters. As the southern coast and the rest of the Southeast Brazilian coast, the large number of shellmounds located in the São Paulo portion beheld information of great potential. However, in the study conducted by Mendonça de Souza et al. (2009) the scarcity of paleopathological data on the São Paulo series was highlighted, which when presented in the literature are generally restricted to the two or three best studied series. This exploratory study aimed to generate data about lifestyle of the shellmound-builters groups of the coast of São Paulo from the patterns of occurrence and distribution of signs indicative of osteoarthritis. The synovial joints of 48 individuals from two coastal sambaquis of Baixada Santista were analyzed for frequency and distribution of the following signs of osteoarthritis: pitting; eburnation; erosion; superficial new bone formation; lipping and osteophytes, considering its differentiated occurrence between surface and margin of the articular area. A high prevalence of injuries was noticed in most prominent articular areas. The data suggests a characterization of osteoarthrosis in these populations as a generalized process at the population and individual level.

Page generated in 0.1302 seconds