• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 1
  • 1
  • Tagged with
  • 44
  • 44
  • 44
  • 43
  • 14
  • 9
  • 9
  • 9
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Biomecânica da aorta torácica e abdominal: estudo em cadáveres / Biomechanical properties of the thoracic and abdominal aorta: an autopsy study

Ninomiya, Otavio Henrique 26 March 2015 (has links)
INTRODUÇÃO: O tratamento endovascular das doenças da aorta é modalidade consagrada atualmente, sendo realizado em indivíduos jovens e idosos, tanto na aorta torácica quanto na abdominal. Esta terapia baseia-se numa interação adequada entre a endoprótese e a parede aórtica. Neste sentido, o conhecimento do comportamento biomecânico da aorta é fundamental. A aorta humana é uma estrutura complexa, com comportamento biomecânico diferente de acordo com a idade, a região e a presença de doenças. Estudos com biomecânica da aorta humana não aneurismática são escassos. OBJETIVOS: Analisar os parâmetros biomecânicos de falência e as características histológicas da aorta torácica e abdominal humana, correlacionando-os com idade e gênero. MÉTODO: Testes destrutivos uniaxiais de espécimes removidos de 26 aortas frescas de cadáveres foram realizados num aparelho de tração universal. Os parâmetros biomecânicos de falência avaliados foram: força, tensão, estresse, deformação e energia de deformação. Foi realizado estudo histológico do tecido aórtico para quantificação de fibras colágenas, musculares e elásticas. RESULTADOS: Foram analisados os testes biomecânicos válidos de 153 espécimes, sendo 95 da aorta torácica e 58 da aorta abdominal. Na comparação entre aorta torácica e abdominal, realizada por análise de variância, foi observado que diâmetro (30,45 versus 23,99 mm; p < 0,001), espessura (1,69 versus 1,44 mm; p < 0,001), força máxima (6,18 versus 4,85 N; p = 0,001), tensão de falência (19,88 versus 14,53 N/cm; p = 0,001), deformação de falência (0,66 versus 0,49; p = 0,003) e a percentagem de fibras elásticas (19,39 versus 14,06 %; p = 0,011) foram maiores, com significância, na aorta torácica. As correlações de Spearman entre idade e força máxima, estresse de falência, tensão de falência, deformação de falência e energia de deformação foram negativas e significativas na aorta torácica e abdominal. As aortas do sexo masculino, através do teste t de Student, apresentaram maior força máxima e tensão de falência. Não houve diferença na composição histológica entre os gêneros. CONCLUSÕES: A aorta torácica é mais resistente e elástica que a aorta abdominal. O conteúdo de fibras elásticas é maior na aorta torácica. Os idosos apresentam aortas menos resistentes e mais rígidas que os jovens. A aorta do sexo masculino é mais resistente / INTRODUCTION: The endovascular repair of aortic diseases is currently widely performed among young and elderly patients, in both the thoracic and abdominal aorta. This treatment is based on an appropriate interaction between the stent graft and the aortic wall. Thus, it is essential to understand the biomechanical behavior of the aorta. The human aorta is a complex vessel with different biomechanical behaviors according to age, location and diseases. There are few biomechanical studies of the human nonaneurysmal aorta. OBJECTIVES: To analyze the biomechanical properties and histological composition of the human aorta according to age and gender. METHODS: Twenty-six human aortas were harvested whole from fresh cadavers during their autopsies. Each aorta was cut into strips for mechanical testing. Uniaxial tensile tests were performed on a tensile-testing machine. The failure load, failure stress, failure tension, failure strain and strain energy were calculated. A histological study was performed to measure the amount of collagen, elastin and smooth muscle cells in the aortic wall. RESULTS: A total of 153 strips were studied (95 from the thoracic aorta and 58 from the abdominal aorta). The diameter (30.45 versus 23.99 mm; p < 0.001), thickness (1.69 versus 1.44 mm; p < 0.001), failure load (6.18 versus 4.85 N; p = 0.001), failure tension (19.88 versus 14.53 N/cm; p = 0.001), failure strain (0.66 versus 0.49; p = 0.003) and elastin amount (19.39 versus 14.06 %; p = 0.011) were all significantly higher for the thoracic aorta than for the abdominal aorta. There was a significant negative Spearman\'s correlation between age and failure load, failure stress, failure tension, failure strain and strain energy. Male aortas had a higher failure load and failure tension than female aortas. No difference in the histological composition was found between the genders. CONCLUSIONS: The thoracic aorta has a higher strength and elasticity than the abdominal aorta. The elastin amount is higher in the thoracic aorta than in the abdominal aorta. The elderly have weaker and stiffer aortas than the young. Male aortas have a higher strength than female aortas
32

Respostas das enzimas antioxidantes em abacaxizeiro após injúria foliar

Nascimento, Vitor de Laia 22 February 2013 (has links)
Made available in DSpace on 2016-12-23T13:48:25Z (GMT). No. of bitstreams: 1 Vitor de Laia Nascimento - texto.pdf: 8002320 bytes, checksum: d923e8ffb747554b279471742bf9ad9d (MD5) Previous issue date: 2013-02-22 / O abacaxizeiro (Ananas comosus var. comosus) é uma das frutíferas tropicais mais produzidas no mundo. O Brasil destaca-se mundialmente na produção desta fruta e o Espírito Santo vem mostrando potencial nacional de produtividade. Doenças e pragas constituem fatores restritivos para o alcance de uma produtividade ideal em qualquer cultura agrícola. O abacaxizeiro é uma planta que pode ser afetada por várias doenças causadas por fungos, bactérias e vírus, destacando-se em importância econômica a fusariose. As respostas de hipersensibilidade são os primeiros eventos que ocorrem nas células das plantas em resposta aos estresses bióticos e abióticos. Há síntese de espécies reativas de oxigênio (EROs) como peróxido de hidrogênio (H2O2), hidroxila (OH-) e superóxido (O2 -) que podem produzir danos oxidativos nos seres vivos como forma de proteção. As plantas possuem um sistema de defesa bem desenvolvido contra as EROs, constituído por uma complexa gama de antioxidantes enzimáticos e não enzimáticos que protegem as células dos danos oxidativos. O processo de infecção de diversos fungos, como o causador da fusariose do abacaxizeiro, é dependente de injúria nos tecidos da planta. O aumento da expressão e atividade das enzimas antioxidantes está correlacionado com a defesa de plantas à fitopatógenos e pragas. O objetivo foi caracterizar a resposta diferencial entre duas cvs de abacaxizeiro, Vitória (resistente à fusariose) e Pérola (susceptível à fusariose), ao estresse oxidativo gerado pela injúria foliar. Para isso foi determinada a concentração de proteínas solúveis totais das duas cvs, Vitória e Pérola, com e sem injúria foliar, quantificado e comparado à atividade das enzimas superóxido dismutase (SOD EC 1.15.1.1), peroxidase do ascorbato (APX EC 1.11.1.11) e catalase (CAT EC 1.11.1.6) após o tratamento de injúria foliar em diferentes tempos e caracterizado os perfis das proteínas solúveis totais e das isoenzimas de SOD e CAT em SDS-PAGE nos tempos em que houver melhor resposta. Como primeiro resultado, temos que não há diferença das proteínas solúveis totais entre as cultivares e os tratamentos nos tempos analisados. Também foi demonstrado que as enzimas antioxidantes da cv Vitória apresentam significativa diferença de atividade em relação às da Pérola. A SOD da cv. Vitória apresentou pico de resposta aos 15 minutos após a injúria. A APX apresentou resposta diferencial, para Vitória, aos 30 e 45 minutos após injúria foliar. Já a CAT da cv. Vitória apresentou um pico de resposta diferencial aos 45 minutos. As análises em SDS-PAGE com padrões de SOD e CAT, aos 15, 30 e 45 minutos após a injúria foliar demonstraram que não há diferença quantitativa entre as enzimas analisadas. Na cv Vitória há correlação entre a atividade de enzimas antioxidantes e a resposta à injúria foliar. Porém a atividade não está diretamente relacionada à concentração das enzimas. Por não haver grande diferença na expressão protéica sugere-se que reguladores e cofatores dessas enzimas apresentem fundamental importância nestes mecanismos / The pineapple (Ananas comosus var. comosus) is a tropical fruit of the most produced in the world. The Brazil stands out worldwide in the production of this fruit and the Espirito Santo state are showing potential national productivity.Diseases are limiting factors for the achievement of an optimum productivity in any crop. The pineapple is a plant that can be affected by various diseases caused by fungi, bacteria and viruses, especially in economic importance fusariosis. The hypersensitivity responses are the first events that occur in the cells of plants in response to biotic and abiotic stresses. There synthesis of reactive oxygen species (ROS) such as hydrogen peroxide (H2O2), hydroxyl (OH-) and superoxide (O2 -) that can produce oxidative damage in living beings as a form of protection. The plants have a well-developed defense system against ROS comprising a complex array of enzymatic and non-enzymatic antioxidants that protect cells from oxidative damage. The infection process of Fusarium pineapple is dependent on mechanical stress, foliar wound. The literature demonstrates that the cultivar (cv) Vitória, resistant to fusarium wilt has accelerated healing compared to a susceptible cv, Peróla. Increased expression and activity of antioxidant enzymes is correlated with plant defense to pathogens and pests. The objective was to characterize the differential response between two cultivars of pineapple, Vitória and Peróla, to the oxidative stress generated by foliar wound. For it was determined the concentration of total soluble protein of the two cvs, Vitória and Peróla, with and without foliar wound, quantified and compared the activity of superoxide dismutase (SOD - EC 1.15.1.1), ascorbate peroxidase (APX - EC 1.11.1.11) and catalase (CAT - EC 1.11.1.6) after treatment of foliar wound at different times and characterized the profiles of total soluble proteins and isozymes of SOD and CAT in SDS-PAGE at the times in which there is better response. Initially we have no difference of total soluble proteins between cvs and treatments for the times analyzed. It was also demonstrated that the antioxidant enzymes cv Vitória exhibit significant difference in activity compared to the Pérola. Vitória/ s SOD showed a peak response at 15 minutes after injury. APX showed differential response to Vitória at 30 and 45 minutes after foliar wound. Already / Vitória/ CAT peaked differential response at 45 minutes. The analysis on SDS-PAGE with patterns of SOD and CAT, at 15, 30 and 45 minutes after foliar wound showed no difference between the enzymes quantitatively analyzed. Cultivar / Vitória/ presents correlation between the activity of antioxidant enzymes and response to foliar wound. However the activity was not directly related to the enzymes concentration. Since there is no difference in protein expression we suggest that enzymes regulators and cofactors are important in these mechanisms
33

Parâmetros fenométricos e qualidade da erva-mate em função do sombreamento, vento e cobertura vegetal do solo / Phenometryc parameters and quality of mate-herb as a function of shading, wind and vegetal mulching of the soil

Ferrera, Tiago Silveira 27 February 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The herb mate is a Brazilian tree species from the South and Midwestern of Brazil. The quality of its product is determine by its answers to ecophysiological stress, since it is a climax plant which natural habitat is a microenvironment sheltered by larger arboreal extracts. The use of herb mate leaves and branches as chimarrão and tererê beverages are the best-known and popularized ones in the Southern states of Brazil. Currently, there has been a strong competition from more profitable annual crops expanding, and a growing demand for pharmaceutical and food industries due to its rich composition in phenolic compounds and antioxidants, which concentration depends on the production environment condition, resulting in prices increase of the products obtained and the demand for more favorable environment to high quality. Thus, more appropriate cultivation and handling practices are necessary to different micrometeorological conditions, depending on the region and time of year. The objective of this study was to evaluate the ecophysiological responses of herb mate under different levels of shading, concerning the effect of soil cover by plant residues, and mechanical stress resulting from the increase of wind speed. Two experiments were conduct with the DF /UFSM. In experiment one, conducted with young plants of herb mate, the field, the land cover factor (covered and bared soil) and the percentage factor of plants shading (0, 18, 35 and 50%) were evaluated in a completely randomized design. Each sample consisted of 12 plants of a progeny with four replications. In experiment 2, conducted in field by taking advantage of a side protection structure of an old greenhouse, the shading factors were tested (18 and 35%) and wind speed (natural ( 0), 2, 4 and 6 m s-1), being tht each sample had 12 plants in three repetitions. Ventilation was generated by portable fans of different powers. The results showed that the soil cobetura is beneficial for young plants having an increased height, the number of sprouts and more intense staining green hue. The shading of 35 and 50% had higher gain in dry mass, higher leaf area, more intense green color and increased stomatal opening. As the phytochemical composition the concentration of polyphenols and flavonoids was higher in sombremamentos getting 35% higher antioxidant capacity. The application of forced ventilation reduced the number of shoots and stomatal opening, and the leaves were less intense green color and slightly altering the phytochemical composção of phenolic compounds and flavonoids and antioxidant capacity. Young erveiras have better establishment to higher growth and better development with greater accumulation of phytochemicals compounds covered soils with partial shading of 50% and places with little wind. / A erva-mate (Ilex paraguariensis St. Hil.) é uma planta arbórea nativa do Sul e Centro-Oeste brasileiro. A qualidade de seu produto é determinada pelas respostas dessa planta a estresses ecofisiológicos, por tratar-se de uma planta climácica em que seu habitat natural é um microambiente abrigado por extratos arbóreos maiores. A utilização das folhas e ramos da erva-mate como chimarrão e tererê são os mais conhecidos e popularizados nos estados da região Sul do Brasil. Atualmente observa-se uma forte competição com culturas anuais mais rentáveis em expansão e uma demanda crescente pela indústria farmacêutica e alimentícia, devido a sua composição rica em compostos fenólicos e antioxidantes, cuja concentração depende da condição do ambiente de produção, resultando em aumento dos preços dos produtos obtidos e na procura do ambiente mais favorável à alta qualidade. Assim, são necessárias práticas de cultivo e manejo mais adequadas às diferentes condições micrometeorológicas, decorrentes da região e da época do ano. O objetivo deste trabalho foi o de avaliar as respostas fenométricas e qualidade da erva-mate sob diferentes níveis de sombreamento, quanto ao efeito da cobertura do solo por restos vegetais e ao estresse mecânico ocasionado pelo aumento da velocidade do vento. Foram conduzidos dois experimentos junto ao Departamento de Fitotecnia UFSM. No experimento 1 conduzido com plantas jovens de erva-mate, a campo, avaliou-se o fator cobertura do solo (solo coberto e desnudo) e o fator percentual de sombreamento das plantas (0, 18, 35 e 50%) em um delineamento inteiramente causualizado. Cada parcela se constituiu de 12 plantas de um progênie, com 4 repetições. No experimento 2, conduzido a campo com uma estrutura de proteção lateral foram, testados os fatores sombreamento (18 e 35%) e o velocidade do vento (natural ( 0), 2, 4 e 6 m s-1), sendo cada parcela constituída por 12 plantas, em três repetições. A ventilação foi gerada por ventiladores portateis de diferentes potências. Os resultados demonstraram que a cobetura do solo é benéfica para as plantas jovens havendo um aumento na altura, no número de brotos e coloração com tonalidade verde mais intenso. Os sombreamentos de 35 e 50% apresentaram maior ganho na massa seca, maior área foliar, cor verde mais intensa e aumento da abertura estomática. Quanto a composição fitoquímica a concentração de polifenóis e flavonoides foi maior nos sombremamentos 35% obtendo maior capacidade antioxidante. A aplicação da ventilação forçada reduziu o número de brotos e a abertura estomática, sendo que as folhas apresentaram coloração verde menos intensa e pouco alterando a composção fitoquímica dos compostos fenólicos e flavonoides e a capacidade antioxidante. As erveiras jovens possuem uma melhor estabelecimento com maior crescimento e melhor desenvolvimento com maior acúmulo de compostos fitoquímicos em solos cobertos, com sombreamento parcial de até 50% e locais com pouco vento.
34

Análise biomecânica e histológica do colo do aneurisma da aorta abdominal infrarrenal: estudo em necrópsia / Biomechanical and histological analysis of the infrarenal abdominal aortic aneurysm neck: a necropsy study

Andre Brito Queiroz 04 November 2015 (has links)
INTRODUÇÃO: O colo dos aneurismas da aorta abdominal infrarrenal é o principal local de interação entre a parede aórtica e as próteses utilizadas no seu tratamento, pela técnica aberta ou endovascular. A dilatação do colo no acompanhamento pósoperatório, levando a falhas no tratamento, demonstra a importância de um colo confiável para um reparo eficiente em longo prazo. OBJETIVOS: Determinar as propriedades biomecânicas e histológicas do colo do aneurisma da aorta abdominal infrarrenal, comparando os resultados com as propriedades da aorta suprarrenal e da parede anterior do aneurisma. MÉTODOS: Dezesseis aneurismas da aorta abdominal infrarrenal encontrados em necrópsia foram removidos e dissecados em laboratório. A anatomia original dos aneurismas foi restabelecida com o auxílio de um balão complacente inserido na luz dos espécimes, sendo que aneurismas com um colo mais curto que 10 mm foram excluídos. Fragmentos transversais similares da parede anterior do aneurisma, do colo e da aorta suprarrenal foram obtidos com o auxílio de um dispositivo de corte apropriado. Testes de tração uniaxiais destrutivos foram realizados para a obtenção das seguintes propriedades biomecânicas: tensão, estresse, energia de deformação e deformação no momento da falência, além da medida da espessura dos fragmentos. A análise histológica destes fragmentos consistiu na quantificação das fibras colágenas, elásticas e espessura da camada média. RESULTADOS: Em doze aneurismas rotos e quatro não rotos, a análise biomecânica dos fragmentos de tecido arterial não demonstrou diferenças estatisticamente significativas entre os valores médios das propriedades biomecânicas de falência (tensão, estresse, energia de deformação e deformação), assim como para a espessura nos três segmentos estudados. O percentual de colágeno para o colo foi significativamente menor que na parede dos aneurismas (p = 0,010) e não foi significativamente diferente da aorta suprarrenal (p = 0,155). A elastina apresentou percentual significativamente maior no colo (p < 0,001) e na aorta suprarrenal (p < 0,001) quando comparados aos aneurismas. Não houve diferença na quantificação da elastina entre o colo e o segmento suprarrenal (p = 0,457). A espessura da camada média não apresentou diferença estatística relevante entre as três regiões avaliadas (p = 0,660). CONCLUSÕES: Os resultados biomecânicos sugerem que o aneurisma da aorta infrarrenal, ao invés de uma processo localizado, seja resultado de um acometimento aórtico difuso. Tanto a resistência quanto a elasticidade do segmento aneurismático apresentam semelhanças quando comparados aos segmentos aórticos não dilatados. Na análise histológica, nota-se preservação da elastina nos segmentos aórticos não dilatados, enquanto há redução na parede aneurismática; além de maior deposição de colágeno nesta região / INTRODUCTION: The neck of the infrarenal abdominal aortic aneurysm is the principal site of interaction between the aortic wall and the devices used in the repair of these aneurysms, by open or endovascular technique. Postoperative aneurysm neck dilation leading to aneurysm exclusion failures demonstrates the importance of a reliable neck for the long-term efficient repair. OBJECTIVE: To access the biomechanical and histological properties of the infrarenal aortic aneurysm neck, comparing the results with the properties of the suprarenal aorta and the anterior wall of the aneurysm. METHODS: Sixteen infrarenal abdominal aortic aneurysms found in necropsies were removed and dissected in laboratory. The original anatomy of the aneurysms was restored with the aid of a compliant balloon inserted in the specimens lumen and aneurysms with a neck shorter than 10 mm were excluded. Similar transverse fragments from the anterior aneurysm wall, aneurysm neck, and suprarenal aorta were obtained with the aid of a cutting device. Uniaxial destructive tensile tests were performed to obtain the following biomechanical properties: tension, stress, strain energy and strain at the moment of fragment failure, and the thickness of the fragments. Histological analysis was performed with the quantification of collagen and elastin, and middle layer thickness in these three fragments. RESULTS: In twelve ruptured and four unruptured aneurysms, the biomechanical analysis of the fragments showed no statiscally signicant differences between the mean values of the biomechanical properties (tension, stress, strain energy and strain), as well as the thickness of the fragments in the three groups. The percentage of collagen in the neck was significantly lower than in the aneurysm wall (p = 0,010) and was not significantly different from the suprarenal aorta (p = 0,155). Higher percentage of elastin was present in the neck (p < 0,001) and in the suprarenal aorta (p < 0,001) when compared to aneurysms. There was no difference in the quantification of elastin between the neck and the suprarenal segment (p = 0,457). The middle layer thickness showed no significant statistical difference between the three evaluated regions (p = 0,660). CONCLUSIONS: Biomechanical results suggest that the infrarenal aortic aneurysm, rather than a localized process, is a result of diffuse aortic involvement. Both the resistance and elasticity of the aneurysmal segment have similarities when compared to non-dilated aortic segments. In the histological analysis, there is preservation of elastin in non-dilated aortic segments, while there is a reduction in the aneurysmal wall; and there is greater collagen deposition in the aneurysmatic region
35

Avaliação in vitro da transmissão de carga oclusal em próteses sobre implantes em função da inclinação de implantes através de análise fotoelástica / In vitro evaluation of occlusal load transmission in prosthetic implant according to the inclination of implants by photoelastic analysis

Edson Koji Takeshita 01 September 2011 (has links)
A técnica All-on-Four foi idealizada visando diminuir a extensão do cantilever nas reabilitações de pacientes edêntulos com próteses implantossuportadas. Contudo, ainda persistem questionamentos relacionados ao comportamento biomecânico dos implantes e da própria técnica All-on-Four, posto que, questões como a perda óssea peri-implantar e falência de componentes da prótese ainda não estão claramente elucidadas. O objetivo da pesquisa foi avaliar a dissipação de tensões em próteses implantossuportadas dos tipos Branemark e All-on-Four, sob carga oclusal estática, e o papel do lado de balanceio e do comportamento do complexo implantes/próteses. Foram confeccionadas seis réplicas de mandíbula humana em resina fotoelástica, divididas em dois grupos:um com quatro implantes dispostos axialmente e paralelas entre si no espaço interforaminal (mandíbulas Branemark), e outro com quatro implantes inseridos de acordo com a técnica All-on-Four. Confeccionou-se uma prótese total implantossuportada, de maneira que se adaptasse em todas as seis mandíbulas. O experimento foi conduzido com o auxílio de um dispositivo giratório de carga, que permitiu a visualização das mandíbulas por todos os ângulos, sem alteração da carga aplicada. Após a fixação padronizada do corpo de prova no dispositivo, a prótese foi parafusada sobre os implantes da mandíbula. Os carregamentos de carga foram feitos em três pontos: no cantilever da prótese, no primeiro pré-molar e na incisal dos incisivos centrais inferiores. Para cada ponto de aplicação das cargas, fotografaram-se as mandíbulas nos lados de trabalho, de balanceio e na linha mediana, vestibular e na linha mediana também por lingual. Pelos resultados observados, quando as cargas foram aplicadas em regiões mais anteriores da prótese, as tensões nos implantes distais inclinados atenuaramse e as outras regiões da mandíbula apresentaram tensões menores e melhor distribuídas. As franjas também mostraram que a angulação dos implantes distais promoveu mudanças no eixo de rotação do conjunto implantes/prótese. Assim como verificou-se que o implante mais distal do lado de balanceio mostrou atuação conjunta com o implante distal do lado de trabalho nas mandíbulas com implantes axiais e, o mais distal do lado de balanceio nas mandíbulas com implantes inseridos segundo a técnica All-on-Four, mostrou tensão nos ápices, denotando função de estaca. Pela metodologia empregada foi possível concluir que, uma prótese total implantossuportada, segundo a técnica All-on-Four, apresentou melhor melhor dissipação das cargas oclusais e o lado de balanceio teve papel fundamental no auxílio à dissipação de cargas oclusais. / The All-on-Four technique was conceived in order to decrease the length of the cantilever in the rehabilitation of edentulous patients with implant-supported prosthesis. However, still persist questions related to the biomechanical behavior of implants and the proper technique All-on-Four, since issues such as peri-implant bone loss and failure of the prosthetic components are not yet clearly elucidated. The purpose of the study was to evaluate the dissipation of tensions in the Branemark implant-supported prosthesis and All-on-Four, under static occlusal load, and the role of the balancing side and the complex behavior of implants / prostheses. Six replicas of the human mandible were made in photoelastic resin, divided into two groups: one with four implants placed axially and parallel to each other in interforaminal space (Branemark jaws), and another four implants inserted according to the All-on-Four technique. It was made an implant-supported denture, so that would fit in all six jaws. The experiment was conducted with the aid of a rotating load device, which permitted visualization of the jaws from all angles, without changing the applied load. After the standardized setting of specimen in the device, the prosthesis was screwed onto the implants in the jaw. The cargo shipments were made on three points: the cantilever prosthesis, in the first premolar and the lower central incisor incisal. For each point of application of loads, photograph was taken from the work sides of the jaws, balancing and the midline, bucal view and the midline lingual also. By the observed results, when loads were applied to more anterior regions of the prosthesis, the stresses in the distal inclined implants attenuated and other regions of the mandible showed lower stresses and better distributed. The fringes also showed that the angulation of the distal implants promoted changes in the axis of rotation of the implant / prosthesis. As it was found that the most distal implantat on the balancing side showed joint action with the distal implant of the working side in the jaw with axial implants, and the most distal implant on the balancing side of jaw with implants inserted according to All-on Four technique, the tension showed apices, denoting stake function. For the methodology it was concluded that an implant-supported denture, according to the All-on-Four technique, had a better dissipation of occlusal loads and balancing side was fundamental hole in helping to dissipate occlusal loads.
36

Biomecânica da aorta torácica e abdominal: estudo em cadáveres / Biomechanical properties of the thoracic and abdominal aorta: an autopsy study

Otavio Henrique Ninomiya 26 March 2015 (has links)
INTRODUÇÃO: O tratamento endovascular das doenças da aorta é modalidade consagrada atualmente, sendo realizado em indivíduos jovens e idosos, tanto na aorta torácica quanto na abdominal. Esta terapia baseia-se numa interação adequada entre a endoprótese e a parede aórtica. Neste sentido, o conhecimento do comportamento biomecânico da aorta é fundamental. A aorta humana é uma estrutura complexa, com comportamento biomecânico diferente de acordo com a idade, a região e a presença de doenças. Estudos com biomecânica da aorta humana não aneurismática são escassos. OBJETIVOS: Analisar os parâmetros biomecânicos de falência e as características histológicas da aorta torácica e abdominal humana, correlacionando-os com idade e gênero. MÉTODO: Testes destrutivos uniaxiais de espécimes removidos de 26 aortas frescas de cadáveres foram realizados num aparelho de tração universal. Os parâmetros biomecânicos de falência avaliados foram: força, tensão, estresse, deformação e energia de deformação. Foi realizado estudo histológico do tecido aórtico para quantificação de fibras colágenas, musculares e elásticas. RESULTADOS: Foram analisados os testes biomecânicos válidos de 153 espécimes, sendo 95 da aorta torácica e 58 da aorta abdominal. Na comparação entre aorta torácica e abdominal, realizada por análise de variância, foi observado que diâmetro (30,45 versus 23,99 mm; p < 0,001), espessura (1,69 versus 1,44 mm; p < 0,001), força máxima (6,18 versus 4,85 N; p = 0,001), tensão de falência (19,88 versus 14,53 N/cm; p = 0,001), deformação de falência (0,66 versus 0,49; p = 0,003) e a percentagem de fibras elásticas (19,39 versus 14,06 %; p = 0,011) foram maiores, com significância, na aorta torácica. As correlações de Spearman entre idade e força máxima, estresse de falência, tensão de falência, deformação de falência e energia de deformação foram negativas e significativas na aorta torácica e abdominal. As aortas do sexo masculino, através do teste t de Student, apresentaram maior força máxima e tensão de falência. Não houve diferença na composição histológica entre os gêneros. CONCLUSÕES: A aorta torácica é mais resistente e elástica que a aorta abdominal. O conteúdo de fibras elásticas é maior na aorta torácica. Os idosos apresentam aortas menos resistentes e mais rígidas que os jovens. A aorta do sexo masculino é mais resistente / INTRODUCTION: The endovascular repair of aortic diseases is currently widely performed among young and elderly patients, in both the thoracic and abdominal aorta. This treatment is based on an appropriate interaction between the stent graft and the aortic wall. Thus, it is essential to understand the biomechanical behavior of the aorta. The human aorta is a complex vessel with different biomechanical behaviors according to age, location and diseases. There are few biomechanical studies of the human nonaneurysmal aorta. OBJECTIVES: To analyze the biomechanical properties and histological composition of the human aorta according to age and gender. METHODS: Twenty-six human aortas were harvested whole from fresh cadavers during their autopsies. Each aorta was cut into strips for mechanical testing. Uniaxial tensile tests were performed on a tensile-testing machine. The failure load, failure stress, failure tension, failure strain and strain energy were calculated. A histological study was performed to measure the amount of collagen, elastin and smooth muscle cells in the aortic wall. RESULTS: A total of 153 strips were studied (95 from the thoracic aorta and 58 from the abdominal aorta). The diameter (30.45 versus 23.99 mm; p < 0.001), thickness (1.69 versus 1.44 mm; p < 0.001), failure load (6.18 versus 4.85 N; p = 0.001), failure tension (19.88 versus 14.53 N/cm; p = 0.001), failure strain (0.66 versus 0.49; p = 0.003) and elastin amount (19.39 versus 14.06 %; p = 0.011) were all significantly higher for the thoracic aorta than for the abdominal aorta. There was a significant negative Spearman\'s correlation between age and failure load, failure stress, failure tension, failure strain and strain energy. Male aortas had a higher failure load and failure tension than female aortas. No difference in the histological composition was found between the genders. CONCLUSIONS: The thoracic aorta has a higher strength and elasticity than the abdominal aorta. The elastin amount is higher in the thoracic aorta than in the abdominal aorta. The elderly have weaker and stiffer aortas than the young. Male aortas have a higher strength than female aortas
37

Estudo das propriedades histológicas e biomecânicas de fragmentos da parede anterior de aneurismas da aorta abdominal / Study of the histological and biomechanical properties of fragments isolated from the anterior wall of abdominal aortic aneurysms

José Augusto Tavares Monteiro 15 March 2013 (has links)
INTRODUÇÃO: O objetivo deste estudo é determinar as propriedades biomecânicas e histológicas de fragmentos da parede anterior de aneurismas da aorta abdominal. MÉTODOS: Dos pacientes submetidos à correção cirúrgica aberta de aneurisma da aorta abdominal, foram removidos fragmentos da parede anterior do saco aneurismático, divididos em dois espécimes. Um, destinado à análise histológica, para a quantificação de fibras colágenas, elásticas, musculares lisas e grau de atividade inflamatória e outro, pareado, submetido a teste destrutivo uniaxial, obtendo-se características biomecânicas, como, força, tensão e estresse de falência do fragmento. As médias das variáveis paramétricas foram avaliadas com teste t-Student ou análise de variância. Quando significante, utilizou-se teste de Tukey para discriminar as diferenças. As distribuições das variáveis não paramétricas foram avaliadas com teste Mann-Whitney ou análise de Kruskal-Wallis. Quando significante, utilizou-se teste de Dunn para discriminar as diferenças. Os valores de p<0,05 foram considerados estatisticamente significantes. RESULTADOS: Foram considerados os resultados das análises de fragmentos de 90 indivíduos. Os valores médios encontrados para as propriedades biomecânicas relacionadas à resistência do tecido aórtico (falência) foram força = 4,98±2,22 N, tensão = 13,18±5,98 N/cm e estresse = 103,14±47,09 N/cm2. A deformação média dos fragmentos até a falência foi de 0,39±0,12. Os fragmentos dos aneurismas de diâmetros transversos máximos maiores ou iguais a 5,5 cm apresentaram valores médios de força, tensão e estresse de falência (5,32±2,07 N, 13,83±5,58 N/cm e 103,02 N/cm2) maiores que os fragmentos de aneurismas de diâmetros menores que 5,5 cm (4,1±2,41 N, 10,82±6,48 N/cm, 77,03 N/cm2), com significância estatística para os três parâmetros de resistência do material. Não foram identificadas diferenças entre os valores médios de deformação de falência entre estes grupos (0,41±0,12 x 0,37±0,14 p = 0,260), bem como entre os valores médios de espessura dos fragmentos (1,58±0,41 x 1,53±0,42 mm p = 0,662). Os valores percentuais médios na composição dos fragmentos foram para as fibras colágenas (coloração de tricrômico de Masson) de 44,34±0,48%, para as fibras colágenas (coloração de picrosirius) de 61,85±10,14%, para as fibras musculares lisas (imuno histoquímica/alfa actina) de 3,46±2,23% e para as fibras elásticas (coloração de Verhoeff) inferior a 1% (traços). Não foram identificadas diferenças entre o percentual destes elementos na composição de fragmentos provenientes da parede anterior de aneurismas de diâmetro transverso máximo >= 5,5 cm e < 5,5 cm. Foi caracterizada uma atividade inflamatória mais intensa nos fragmentos provenientes de aneurismas de diâmetro transverso máximo >= 5,5 cm quando comparados aos fragmentos provenientes de aneurismas de diâmetro transverso máximo < 5,5 cm (grau 3 - 70% x 28,6% p = 0,011). Comparando-se os aneurismas sintomáticos versus os assintomáticos não foram identificadas diferenças significativas para as propriedades biomecânicas de falência dos fragmentos (força = 5,32±2,36 x 4,65±2,05 N, p = 0,155; tensão = 14,08±6,11 x 12,81±5,77 N/cm, p = 0,154; estresse = 103,02 x 84,76 N/cm2, p = 0,144 e deformidade = 0,38±0,12 x 0,41±0,13, p = 0,287), assim como para a espessura (1,56±0,41 x 1,57±0,41 mm p = 0,848) e composição histológica (fibras colágenas 44,67±11,17 x 44,02±13,79 % p = 0,808; fibras musculares lisas 2,52 x 2,35 %, p = 0,751; fibras elásticas inferior a 1%). CONCLUSÃO: Os fragmentos provenientes da parede anterior do saco aneurismático de aneurismas maiores mostraram-se mais resistentes, não se identificando diferenças entre os fragmentos quanto à espessura e conteúdo da matriz protéica. A maior resistência dos fragmentos de aneurismas maiores provavelmente está relacionada à adaptação da parede para suportar maior grau de sobrecarga hemodinâmica à medida que o diâmetro aumenta. Neste estudo esta adaptação não foi revelada pela análise histológica realizada e demonstra a limitação do estudo de fragmentos isolados de aneurismas para estimar o risco de ruptura dos mesmos / INTRODUCTION: The objective of this study was to determine the biomechanical and histological properties of fragments isolated from the anterior wall of abdominal aortic aneurysms. METHODS: Fragments of the anterior aneurysm wall were excised from the aneurysmatic sac of patients who underwent open surgery for repair of abdominal aortic aneurysm and divided into two specimens. One specimen was sent for histological analysis for quantification of collagen fibers, elastic fibers, smooth muscle cells and degree of inflammatory activity and the other, by uniaxial testing, was used to assess biomechanical properties, such as force, tension, and stress at the time of failure of the material. The means of parametric variables were evaluated with Student\'s t test or analysis of variance. When significant, we used the Tukey test to discriminate differences. The distributions of non-parametric variables were evaluated with Mann- Whitney or Kruskal-Wallis test. When significant, we used Dunn\'s test to discriminate differences. A p-value of less than 0.05 was considered statistically significant. RESULTS: Anterior-wall fragments from a total of 90 patients were considered. The average values of biomechanical parameters related to the resistance of the aorta (failure) were as follows: strength, 4.98±2.22 N; tension, 13.18±5.98 N/cm; and stress 103.14±47.09 N/cm2. The average deformation of the fragments at the time of the failure was 0.39±0.12. Fragments of aortic aneurysm with a maximum transverse diameter larger or equal to 5.5 cm showed average values for strength, tension, and stress at the time of the failure of the material (5.32±2.07 N, 13.83±5.58 N/cm, and 103.02 N/cm2, respectively), which were higher than those of fragments of aneurysms with diameters less than 5.5 cm (4.1±2.41 N, 10.82±6.48 N/cm, 77.03 N/cm2, respectively). The differences in the 3 parameters were statistically significant. However, no differences were observed between the groups in relation to average failure deformation (0.41±0.12 × 0.37±0.14; p = 0.260) and thickness of the analyzed fragments (1.58±0.41 × 1.53±0.42 mm; p = 0.662). The average values of fiber compositions of the fragments were as follows: collagen fibers, 44.34±0.48% and 61.85±10.14% (assessed using Masson trichrome staining and picrosirius red staining, respectively); smooth muscle cells, 3.46±2.23% (immunohistochemistry/alpha-actin); and elastic fibers, less than 1% (traces) (Verhoeff-van Gieson staining). No differences in fiber percentages were observed in the fragments from aneurysms with a maximum transverse diameter >= 5.5 cm and < 5.5 cm. A more intense inflammatory activity was assessed in fragments from aneurysms with maximum transverse diameter >= 5.5 cm than in fragments from aneurysms with maximum transverse diameter < 5.5 cm (grade 3 - 70% × 28.6%; p = 0.011). Compared to asymptomatic aneurysms, fragments from symptomatic aneurysms showed no significant differences in the biomechanical properties at the time of the failure (strength, 5.32±2.36 × 4.65±2.05 N, p = 0.155; tension, 14.08±6.11 × 12.81±5.77 N/cm, p = 0,154; stress, 103.02 × 84.76 N/cm2, p = 0.144; and deformity, 0.38±0.12 × 0.41±0.13, p = 0.287), thickness of the fragments (1.56±0.41 × 1.57±0.41 mm, p = 0.848) and histological composition (collagen fibers, 44.67±11.17 × 44.02±13.79%, p = 0.808; smooth muscle fibers, 2.52 × 2.35%, p = 0.751; elastic fibers, <1%). CONCLUSION: Fragments of the anterior wall removed from the aneurysmatic sac of large aneurysms appeared to be more resistant than those from small aneurysms. No differences between the aneurysm fragments were observed with respect to thickness and matrix protein content. The high resistance of fragments of larger aneurysms is probably attributable to the adaptation of the wall to support a high hemodynamic stress as the diameter of the aorta increases. In this study, this adaptation was not shown by histological analysis. This suggests a limitation of this study for assessing the risk of rupture based on isolated aneurysm fragments
38

Análise fractográfica e de resistência mecânica de duas marcas de placas de titânio em fraturas simuladas em corpo de hemimandíbulas de alumínio / Fractographic and mechanical analysis of two brands of titanium plates in simulated body fractures of aluminum hemimandibles

Moura, Andrezza Lauria de, 1982- 06 April 2013 (has links)
Orientadores: Marcelo Marotta Araújo, Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T00:56:38Z (GMT). No. of bitstreams: 1 Moura_AndrezzaLauriade_M.pdf: 4155630 bytes, checksum: 44572134d9e31084a7892cb0866a1d79 (MD5) Previous issue date: 2013 / Resumo: O propósito no estudo foi avaliar comparativamente, através de teste de carregamento linear e análise fractográfica, duas marcas de material de fixação interna estável com dois métodos de fixação em fraturas simuladas em corpo de hemimandíbulas de alumínio. O trabalho foi dividido em dois grupos: Grupo I com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação com duas placas de titânio de quatro furos do sistema 2,0mm, sendo uma placa na zona de compressão e outra zona de tensão, totalizando 20 placas de titânio; e grupo II, com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação de uma placa de titânio de quatro furos do sistema 2,0mm na zona neutra de corpo de mandíbula, totalizando 10 placas de titânio. Testes de carregamento linear foram realizados por meio da máquina para ensaio universal mecânica Instron®, até a fratura do material. Após os testes, foram realizadas as análises fractográficas das superfícies de fratura dos materiais de fixação (grupos I e II) através de microscópio eletrônico de varredura FEI®, com o objetivo de analisar orientações, texturas e falhas dos materiais. Médias e desvio padrão das cargas e deslocamentos foram avaliados aplicando-se a Análise de Variância (ANOVA) two-way e teste de Tukey em nível de significância de 5%. Os resultados mostraram que o método de fixação com duas placas retas de quatro furos apresentou maior resistência à carga (p<0,01), quando comparado ao grupo de apenas uma placa de titânio na zona neutra mandibular. Ainda, a marca Traumec® apresentou maior resistência mecânica (p<0,01) quando utilizada no método com duas placas de fixação e a marca Tóride® (p<0,01) apresentou maior resistência as carga quando utilizada no método com apenas uma placa de fixação. A fractografia informou que todas as fraturas ocorreram por sobrecarga dúctil e micromecanismo alveolar / Abstract: The purpose of the study was to comparatively evaluate, through linear load test and fractographic analysis, two brands of stabel internal fixation in two methods of fixation in simulated body fractures in aluminium hemimandibules. The study was divided into two groups: Group I with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the compression zone and another one in tension zone, totaling 20 miniplates; and group II, with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the neutral zone of the mandible, totaling 10 miniplates. Mechanical tests were performed via mechanical universal testing machine Instron¿ until complete failure of the material. After the tests, fractography analysis of fractured surfaces were done in all materials (groups I and II) by a FEI¿ scanning electron microscopy, with the objective of analyzing orientation and textures of materials failures. Means and standard deviations of load and displacement were evaluated by applying the analysis of variance (ANOVA) two-way and the Tukey test at a significance level of 5%. The results showed that the method of fixation with two titanium plates with four holes showed higher resistance loads (p<0,01), when compared to only one titanium plate in the neutral zone of the mandible. Furthermore, the brand Traumec¿ showed higher mechanical strength (p<0,01) when used in the method with two fixing plates and the brand Toride¿ (p<0,01) showed a higher resistance to loads when used in the method with only one miniplate. The fractography reported that all fractures occurred in ductile overload and alveolar micromechanisms / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestra em Clínica Odontológica
39

Utilização farmacológica de um composto inédito derivado de quinazolina como inibidor potencial da quinase de adesão focal (FAK) no processo de hipertrofia cardíaca em camundongo = Pharmacological use of a novel compound quinazoline derivative as potential inhibitor of the focal adhesion kinase in the process of cardiac hypertrophy in mice / Pharmacological use of a novel compound quinazoline derivative as potential inhibitor of the focal adhesion kinase in the process of cardiac hypertrophy in mice

Cardoso, Leandro, 1979- 07 June 2012 (has links)
Orientador: Kleber Gomes Franchini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-20T23:08:02Z (GMT). No. of bitstreams: 1 Cardoso_Leandro_M.pdf: 3831901 bytes, checksum: 40e5df211d7e6fd923f654bd8d3a1ec1 (MD5) Previous issue date: 2012 / Resumo: Nas doenças do coração ocorre hipertrofia e remodelamento do ventrículo esquerdo com impacto negativo na evolução clínica. Esses fatores influenciam independentemente o risco cardiovascular por elevarem a predisposição a infartos do miocárdio, ao desenvolvimento de insuficiência cardíaca e ao aparecimento de arritmias ventriculares graves. Estruturalmente ocorrem crescimento e degeneração dos miócitos cardíacos, fibrose e alterações da microcirculação. Estas alterações comprometem irreversivelmente a histoarquitetura do miocárdio, limitando a eficácia dos tratamentos convencionais, principalmente no estágio mais avançado caracterizado pela insuficiência cardíaca. A rede de sinalização celular envolvida na resposta das células miocárdicas (miócito e não miócitos) a forças mecânicas tem papel crítico na compreensão da patogênese da hipertrofia. A quinase de adesão focal (FAK), uma enzima associada à sinalização por integrinas, é ativada precocemente e exerce influência no desenvolvimento e sustentação da resposta hipertrófica do miocárdio à sobrecarga pressórica. Nesse estudo foi avaliado o efeito de um composto inédito derivado de quinazolina (BZLO) com potencial ação inibitória da FAK no coração de camundongos submetidos à sobrecarga pressórica por coarctação da aorta. In vitro, esse composto inibiu a atividade catalítica da FAK purificada com IC50 de 1nM. In vivo, o tratamento dos camundongos submetidos à coarctação da aorta com o composto (BZLO) provocou inibição do resíduo Tyr397 da FAK. Demonstrando que o composto não só preveniu, mas também promoveu regressão da hipertrofia do ventrículo esquerdo típica do modelo, acompanhada de atenuação da hipertrofia dos cardiomiócitos e da fibrose intersticial, e preservação da função ventricular. Esses resultados indicam que o tratamento com o composto (BZLO), presumivelmente por inibir a FAK, atenua as alterações estruturais e funcionais provenientes da sobrecarga pressórica crônica no ventrículo esquerdo de camundongos, sugerindo seu potencial como alternativa na prevenção e tratamento da insuficiência cardíaca / Abstract: Cardiac remodeling and hypertrophy have negative impact in the evolution of heart disease. They raise predisposition to myocardium infarction, heart failure and fatal ventricular arrhythmias, being independent markers of cardiovascular prognosis. Cardiomyocyte growth followed by degeneration, interstitial fibrosis and alterations in the microcirculation can be detected structurally in hypertrophic hearts. These alterations jeopardize myocardium tissue architecture irreversibly limiting therapeutic efficacy especially in advanced stages of disease with heart failure. The understanding of signaling network in response to mechanical stimuli is crucial in the study of cardiac hypertrophy. Focal adhesion kinase (FAK) an enzyme linked to signaling by integrins is activated in response to pressure overload and influences the development of myocardial hypertrophic response. In the present study, a compound based on quinazoline scaffold which is a FAK inhibitor, named BZLO, is examined for its effects on cardiac hypertrophy of mice model of aortic constriction. BZLO strongly inhibits catalytic activity of purified FAK in vitro (IC50 = 1nM). Satisfactory bioavailability of BZLO was observed after oral administration. BZLO treatment decreased FAK phosphorylation at Tyr397 and attenuated cardiomyocyte growth and interstitial fibrosis preserving cardiac function in the mice model of chronic pressure overload induced by aortic constriction. These findings suggest that BZLO is effective in attenuating the deleterious structural and functional consequences of chronic pressure overload in mice heart, suggesting that it has the potential to be considered as an option for the prevention and treatment of heart failure / Mestrado / Fisiopatologia Médica / Mestre em Ciências
40

Ossos do ofício: análise de marcadores de estresse ocupacional em séries esqueléticas da Baixada Santista - SP / Analysis of occupation stress markers in skeletal series of shellmounds of Baixada Santista - SP

Rafael Amaral Stabile 19 July 2017 (has links)
As últimas décadas viram ser publicados diversos trabalhos que se debruçaram sobre aspectos paleopatológicos de séries esqueléticas de sítios do tipo sambaqui. Tal como o litoral Sul e o restante do Sudeste, o seguimento paulista da costa brasileira apresenta grande quantidade de sítios do tipo sambaqui que guardam em si um grande potencial informativo. Entretanto, no levantamento realizado por Mendonça de Souza e colaboradores (2009) sobre os aspectos paleopatológicos dos sambaquis brasileiros, salienta-se a escassez de dados sobre as séries paulistas, que quando aparecem na literatura em geral restringem-se à duas ou três séries melhor estudadas. O presente estudo, de caráter exploratório, procurou gerar dados sobre o modo de vida dos grupos construtores de sambaquis do litoral de São Paulo, a partir dos padrões de ocorrência e distribuição dos sinais indicativos de osteoartrose. As articulações sinoviais de 48 indivíduos provenientes de dois sambaquis litorâneos da Baixada Santista foram analisadas quanto a frequência e distribuição dos seguintes sinais de osteoartrose: porosidade; eburnação; erosão; exostoses superficiais; labiamentos e osteófitos, considerando sua ocorrência diferenciada entre superfície e bordo da área articular. As séries estudadas apresentaram prevalências elevadas dos marcadores na maioria das áreas articulares destacadas. Os dados apontam para uma caracterização da osteoartrose nestas populações como um processo generalizado a nível populacional e individual e reforçam a interpretação vigente de que os grupos sambaquieiros devem ter exercido um domínio generalizado sobre as fontes alimentares e recursos necessários para a reprodução da vida material cotidiana. / The past decades witnessed the publication of several papers that dealt with paleopathological aspects of skeletal series of shellmoun-builters. As the southern coast and the rest of the Southeast Brazilian coast, the large number of shellmounds located in the São Paulo portion beheld information of great potential. However, in the study conducted by Mendonça de Souza et al. (2009) the scarcity of paleopathological data on the São Paulo series was highlighted, which when presented in the literature are generally restricted to the two or three best studied series. This exploratory study aimed to generate data about lifestyle of the shellmound-builters groups of the coast of São Paulo from the patterns of occurrence and distribution of signs indicative of osteoarthritis. The synovial joints of 48 individuals from two coastal sambaquis of Baixada Santista were analyzed for frequency and distribution of the following signs of osteoarthritis: pitting; eburnation; erosion; superficial new bone formation; lipping and osteophytes, considering its differentiated occurrence between surface and margin of the articular area. A high prevalence of injuries was noticed in most prominent articular areas. The data suggests a characterization of osteoarthrosis in these populations as a generalized process at the population and individual level.

Page generated in 0.0852 seconds